Maintenance Manual. Liquid Level Transmitter CT801-SI, CT801-TA

Similar documents
Technical Manual. Liquid Level Transmitter CT801-LB/S

Maintenance Manual. Electropneumatic Level Measuring System TYPE TN3801

Installation, Operation and Maintenance Manual for Back Pressure Regulator

Float Operated Level Controllers

DPC-30 DPC-100. Reference Manual

_ pressure transducers. User Manual

Installation, operating and maintenance Instructions for Seemag bypass level indicator

MASS-STREAM TM Instruction Manual. D-6200 Analog Mass Flow Meters / Controllers

Model PDT Dewpoint Transmitter

FOR INSTALLING CO 2 BLENDER KIT (P/N IN BEER SYSTEM

GILMONT ACCUCAL FLOWMETERS

ACV-10 Automatic Control Valve

THE BP-301 SERIES. Operating and Service Manual. Series includes all variants of BP-301 (LF 0.1Cv / MF 0.5Cv)

THE MF-400 SERIES. Operating and Service Manual. Series includes all variants of MF-400/401

THE HF-300 SERIES. Operating and Service Manual. Series includes all variants of HF-300/301

NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE

INSTALLATION & MAINTENANCE INSTRUCTIONS

Installation and Operation Manual

Instruction Manual - Diaframless TM Ejector Chlorine, Sulfur Dioxide and Ammonia

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER FILTER DRYER

299H Series. Introduction. P.E.D. Categories. Specifications. Installation. Warning. Installation Guide English September 2012

KTM 50 (DN ) Installation, maintenance and operating instructions

RD(H)20/25 Pressure-Reducing Regulator User Manual

L 100. Bubble-Tube Level System. Installation, Operation and Maintenance Instructions

FTS SUBMERSIBLE PRESSURE TRANSMITTER USER S MANUAL

Type 3709 Pneumatic Lock-up Valve. Translation of original instructions. Mounting and Operating Instructions EB 8391 EN

INSTALLATION INSTRUCTIONS. CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION

Mini-Pro CO2 Sensor User s Manual - ANALOG MODEL -

Type ACE97. Introduction. Installation. P.E.D. Categories. Specifications. Overpressure Protection. Installation Guide English May 2002

PX3005. Rangeable Industrial Pressure Transmitter M-5721/1018

Installation and operating manual. Pneumatic control station LK product no: PCS 1-10

Magnetic level switch type MR783 Instruction Manual

Electro-Pneumatic Converter YT-940 SERIES

Welker Sampler. Model GSS-1. Installation, Operation, and Maintenance Manual

SAPAG. Safety valves, type 5700 Storage, Use, Operation and Maintenance Instructions. IMPORTANT NOTICE

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

Instruction Manual O-Ring Ejector Chlorine & Sulfur Dioxide to 500 PPD (10 kg/h)

Installation, Operation, and Maintenance Manual

Installation, Operation, and Maintenance Manual

RB Series Regulating System

SLAM-SHUT VALVE. Type OSE CONTENTS INTRODUCTION CHARACTERISTICS. Scope of Manual. Material. Product Description. Connections

Model VR6 System. Installation, Operation & Maintenance

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

T-900 Series. Operation Manual for T-960, T-965, T-970, T-975, T975-CPF

Flamco Flamco-Fill STA Flamco-Fill STM

Instruction Manual Differential Pressure Transmitter

Pressure Measurement Single-range transmitters for general applications

CLEMENTS. ANA Oxygen Regulator with Yoke Connector. User Manual. Manual No. ANA Issue 1

APCO ARV CLEAN WATER AIR RELEASE VALVES. Model 50A

RAM 4021-PR. Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

Series INTELLIGENT PRESSURE- AND LEVEL TRANSMITTERS For all industries. Description ALL STAINLESS DESIGN

Flow controller Type ED/CCB311 Instruction manual

Tank Blanketing Pressure Regulators RHPS Series

HUPF Series DESCRIPTION APPLICATION INSTRUCTION SHEET GAS PRESSURE REGULATOR WITH INCORPORATED FILTER EN1C-0003NL05 R1205.

Your safety and the safety of others are very important.

Preferred Instruments Danbury, CT USA

Marschalk Model # 94000

Measurement of Low GAS & Liquid Flows

GAS VALVE RETROFIT KIT Pull Through Tube Heater Models

DS05C,D,G Dial Set Pressure Regulating Valves

RG1200 Service and Repair Manual

INSTALLATION & MAINTENANCE INSTRUCTIONS DESCRIPTION SPECIFICATIONS. CE (EMC) Compliant

LRS(H)4 Pressure-Reducing Regulator User Manual

Operating and maintenance manual Filter and reducing station Series / 1.0

INSTRUCTION MANUAL MP4AR Remote Convection Gauge Range: 1 x 10-3 Torr to 1 x 10+3 Torr

Model B Wire Wet Oxidant Gas Transmitter. 6 Iron Bridge Drive Unit 1 & 2 Gatehead Business Park

QBS Electronic Pressure Regulator

PURA. Pure Gas Dewpoint Transmitter. Users Guide

2600T Series Pressure Transmitter Models 264DC Differential and 264HC Gage Level Transmitters. Kent-Taylor

J Air and Water Kit Instructions Part# 02584

LRS(H)4 USER MANUAL. Read the complete manual before installing and using the regulator.

Installation, Operation, and Maintenance Manual

CS Controlled Dissolved Gas assembly with optional CS Air Aspirator assembly. Installation and Operation information

Easy Nest Kits. Installation Suggestions

CSA Sample Draw Aspirator Adapter Operator s Manual

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

PULSAR 5000 SERIES OPERATING & INSTALLATION INSTRUCTIONS SERIES 5000 PLEASE READ CAREFULLY BEFORE INSTALLING

SPECIFICATIONS ATTENTION

Pressure Transmitters 36 F-27839

Manual Actuated Boiler Blowdown Valves

TECHNICAL DATA. Page 1 of 12

OSAT Series. Intrinsically Safe Infrared Temperature Sensor Operator's Guide

ERNG-X TESCOM Product Manual

Exercise 5-2. Bubblers EXERCISE OBJECTIVE DISCUSSION OUTLINE. Bubblers DISCUSSION. Learn to measure the level in a vessel using a bubbler.

1805 Series Relief Valves

Model Secure-Gard Pilot Operated Vent Valve SECTION II. Remove all packing material inside and outside of the valve prior to installation.

D Series Air and Water Kit Part# 02550

RK-IR Sample Draw Aspirator Adapter Operator s Manual

OPTIBAR P 1010 C Technical Datasheet

MPC1-D-1000/MPC1-D-3000 Manual Pressure Controller for Differential Pressure User s Manual

64 Series Pressure Reducing Regulators

Flowmeter. Original operating manual DFM

Installation Instructions WARNING: WARNING: WARNING: LP AND HIGH ALTITUDE LP GAS CONVERSION KIT FOR UNITED STATES INSTALLATIONS

Series INTELLIGENT PRESSURE- AND LEVEL TRANSMITTERS For all industries. Description ALL STAINLESS DESIGN

Installation Instructions

Anti-flood device Model B-1

High-performance submersible pressure transmitter For level measurement Model LH-10

Safety. Operating instructions Solenoid valve for gas VG 10/15 VG 65 DANGER. Contents WARNING CAUTION. Changes to edition 11.14

Fisher DVI Desuperheater Venturi Inline

SDX Submersible Depth Transmitter User Manual

Transcription:

CT801-SI, CT801-TA Maintenance Manual SAS au Capital de 2 158 244-444 871 933 R.C.S. Bourges - APE : 2651B Headquarter : 9, rue Isaac Newton - 18000 Bourges - France

Maintenance Manual CT801-SI, CT801-TA 1 st Edition Released February 2013

TABLE OF CONTENTS 1. INTRODUCTION... 4 2. DESCRIPTION... 5 2.1 Pneumatic modulator... 5 2.2 Electric conditioner... 6 3. PREVENTIVE MAINTENANCE... 7 3.1 Quarterly controls... 7 3.2 Yearly controls... 7 3.3 Yearly parts replacement... 8 4. TROUBLESHOOTING GUIDE... 8 5. REMEDIAL MAINTENANCE... 11 5.1 Recommended spare parts... 11 5.2 Recommended tool kit... 11 5.3 Air supply filter : replacement... 12 5.4 Venting nipple : replacement... 12 5.5 Bubbling flow adjustment... 12 5.6 Electronic conditioner : replacement... 12 5.7 Electronic conditioner : calibration... 13 5.8 Overpressure protection valve : check... 14 6. SPARE PARTS LIST... 15 7. INFORMATIONS... 17 7.1 Request for Service form... 17 7.2 Return for repair form... 17 7.3 Reference of Honeywell Marine Customer Service... 17 8. PERSONAL NOTES... 18 APPENDIX A... 19

1. INTRODUCTION The Level Transmitter CT801 Series is designed for measuring the level of all types of liquid products in all kinds of tanks such as ballast tanks, service tanks,, from the hydrostatic pressure of an air-flow bubbling through a pipe which reaches the bottom of the tank. This pressure is transmitted to an electronic conditioner including a pressure sensor, providing an electrical analog output signal. Two models are available : CT801-SI, the standard model, providing an electric current from 4 to 20 ma in the 24 Vdc typical power supply loop. Two wires are necessary for the CT801-SI connection to the monitoring system. CT801-TA, designed for connection to a TA840 or EM940 Radar level transmitter : powered by the 5 Vdc source, the output signal is a voltage ranging from 0.5 to 2.5 Vdc connected to an analog input of the Radar. Three wires are necessary to connect the CT801-TA to the closest Radar transmitter, for cable saving. These models are designed to be used in all hazardous area. The CT801 Series are fitted with a differential pressure sensor, so even if installed on a pressurised tank, the output signal is a direct function of the liquid height. The CT801 Series are fitted with the following mechanical interface, for the best adaptation to all installation conditions : Suffix B : flange PN16 DN50 Suffix R : female threaded coupling 1" BSPP, with optional bracket Suffix R1/4 : female threaded coupling 1/4" NPT, with optional bracket The transmitter is described in the MT5006E Technical Manual. The Installation of the transmitter is described in the MI5006E Maintenance Manual. CT801-SI, CT801-TA Maintenance Manual 4

2. DESCRIPTION The CT801 Series is composed of two main parts : the pneumatic bubbling flow modulator and the electronic signal conditioner. 2.1 Pneumatic modulator The pneumatic bubbling flow modulator is common for all models. It is composed of: Identification plate Enclosure for the electronic conditioner NPT 1/8" coupling for low reference pressure inlet connection (pressurised tank) or venting nipple (non-pressurised tank) Overpressure protection valve NTP 1/8" coupling for outlet connection to pressure indicator (pressure copy) Air supply filter NTP 1/4" coupling for air supply inlet connection Bubbling flow generator, with air flow adjustment NTP 1/4" coupling for flow control Bubbling air return protection valve Process interface and outlet connection of the bubbling probe: - Flange PN 16-DN 50 with threaded coupling 1/2" NPT - Cylindrical 1 BSPP fitting. - Conical 1/4 NPT fitting CT801-SI, CT801-TA Maintenance Manual 5

2.2 Electric conditioner The electronic conditioner board, including the pressure sensor, is placed in a solid housing on top of the pneumatic modulator, ensuring the compactness of the CT801 transmitter. Two kinds are available, one for model CT801-SI, one for model CT801-TA : CT801-SI : Terminals Zero adjustment ("Z" mark) Span adjustment ("S" mark) Type 34052 Type 35445 CT801-TA : Terminals Zero adjustment ("Z" mark) Span adjustment ("S" mark) CT801-SI, CT801-TA Maintenance Manual 6

3. PREVENTIVE MAINTENANCE 3.1 Quarterly controls It is recommended to proceed quarterly to the following visual inspection on each transmitter : a) Air supply filter Close the bubbling line isolating valve, in particular when the CT801 is installed at a place lower than the liquid surface; Close the shut-off valve of air supply; Slowly unscrew the filter cap (see 2.1); let the air supply under pressure flow out; Pull out carefully the filter with its spring; Check the cleanness of the filter, there should be no dark dust marks; Check the integrity of the spring, no corrosion should be visible; Check the integrity of the gasket; Replace the damaged part if any (see 5.3); Screw the filter cap using a spanner 22 mm. a) Venting nipple, if any Slowly unscrew the venting nipple (see 2.1); Check the output signal, no sudden change should be seen; Check the cleanness of the diaphragm, there should be no dark dust marks; Replace the damaged part if any (see 5.4). 3.2 Yearly controls The following controls allow ensuring that all key points for a proper operation of the CT801 transmitter are in good order. Note : These checking operations can be easily performed with Honeywell Marine test tool kit, code 29238. a) Bubbling flow check Close the bubbling line isolating valve, in particular when the CT801 is installed at a place lower than the liquid surface; Slowly unscrew the NPT ¼" plug for flow control (see 2.1); let the bubbling air flow out; Screw the NPT ¼"coupling with a tube connected to the flowmeter; The flow should be 8 to 10 l/h; if uncorrect, proceed to the adjustment (see 5.5); Screw the plug sealed with Teflon tape. a) Zero output check While checking the bubbling flow (see above), the bubbling pressure is zero; The possible low reference pressure if any is also cancelled by closing the isolating valve on the line for the gas pressure over the liquid surface, and lightly opening the relevant inlet; Check the current output : it should be 4 ma ± 0.05 ma for CT801-SI, or 0.5 Vdc ± 0.006 for CT801-TA; if uncorrect, proceed to the complete calibration (see 5.7); Screw the coupling of the line for the gas pressure over the liquid surface sealed with Teflon tape. CT801-SI, CT801-TA Maintenance Manual 7

3.3 Yearly parts replacement Honeywell Marine recommends proceeding yearly to following parts replacement, in order to preserve the best operating conditions and the typical accuracy : a) Air supply filter Replace the filter and its spring (see 5.3). b) Venting nipple, if any (see 5.4). For that purpose, a maintenance kit for one year is available (see 6). 4. TROUBLESHOOTING GUIDE Common failures, causes and remedies are shown below, in tabular form. Refer to overviews in chapter 2 for details. Refer to chapter 5 for remedial maintenance. If this guide doesn't allow to solve the problem, ask for repair to Honeywell Marine, using the Return for Repair Form CAUTION: Observation Cause Remedies Output current stays at a value lower than 3.95 ma on CT801- SI Output voltage stays at a value lower than 0.494 Vcc on CT801- TA When it is suggested, before removing the Electronic module, imperatively close the bubbling line isolating valve, in particular when the CT801 is installed at a place lower than the liquid surface, and close the isolating valve to the gas pressure over the liquid surface if any, as well as the shut-off valve of air supply. - Improper electrical connections - Voltage on terminals should be at least 12 Vdc - Pressure staying in the sensor : remove the electronic PCB with sensor by unscrewing the 4 screws, and pull it off - Check the electrical connections (see MI5006 5.2.1) - If lower, check the power supply and the voltage drop of the Zener barrier and/or the indicator system load, acc. to the diagram in MT5006 5.3 - The output current reaches 4 ma ± 0.05 : check for possible vacuum pressure in the tank; the output current doesn't change : replace the PCB (see 5.6) - No bubbling flow - Check the air pressure, it should be at least 4 bar; if yes, check the bubbling flow (see 3.1) - Improper electrical connections - Voltage on terminals should be at least 4.5 Vdc, typically 5 Vdc - Pressure staying in the sensor : remove the electronic PCB with sensor by unscrewing the 4 screws, and pull it off - Check the electrical connections (see MI5006 5.2.2) - If lower, check the power supply from the TA840 or EM940 Radar transmitter - The output voltage reaches 0.5 Vdc ± 0.006 : check for possible vacuum pressure in the tank; the output voltage doesn't change : replace the PCB (see 5.6) - No bubbling flow - Check the air pressure, it should be at least 4 bar; if yes, check the bubbling flow (see 3.1) CT801-SI, CT801-TA Maintenance Manual 8

Observation Cause Remedies Output current or voltage stays at 4 ma ± 0.05 or 0.5 Vdc ± 0.006 Output current stays at a fixed value within the range on CT801-SI Output voltage stays at a fixed value within the range on CT801-TA Output current or voltage are related to the level in the bottom of the range but doesn't run over a fixed value within the range Output current stays at a fixed value over the range, > 20.05 ma for CT801-SI Output voltage stays at a fixed value over the range > 2.506 Vdc for CT801-TA - No bubbling flow - Check the air pressure, it should be at least 4 bar; if yes, check the bubbling flow (see 3.1) - Major leak on the bubbling line - Check for the proper connection of the bubbling line, or possible leak, for instance proceed to a pressure test (see MI5006 6.1) after closing the isolating valve on bubbling line - No bubbling flow - Check the air pressure, it should be at least 4 bar; if yes, check the bubbling flow (see 3.1) - Pressure staying in the sensor : remove the electronic PCB with sensor by unscrewing the 4 screws, and pull it off - The output current should reach 4 ma ± 0.05; if the output current doesn't change : replace the PCB (see 5.6) - No bubbling flow - Check the air pressure, it should be at least 4 bar; if yes, check the bubbling flow (see3.1) - Pressure staying in the sensor : remove the electronic PCB with sensor by unscrewing the 4 screws, and pull it off - The overpressure protection valve closes within the range - The isolating valve on the bubbling line stays closed - Pressure staying in the sensor : remove the electronic PCB with sensor by unscrewing the 4 screws, and pull it off - The output voltage should reach 0.5 Vdc ± 0.006; if the output voltage doesn't change : replace the PCB (see 5.6) - Check the overpressure protection valve (see 5.8) - Open the isolating valve on the bubbling line - The output current reaches 4 ma ± 0.05 : check for possible overpressure in the tank; the output current doesn't change : replace the PCB (see 5.6) - Bubbling line obstructed - Clear the bubbling line by service valve if present (see MI5006 4.4.2) or by injection of compressed air after closing the isolating valve on bubbling line - The isolating valve on the bubbling line stays closed - Pressure staying in the sensor : remove the electronic PCB with sensor by unscrewing the 4 screws, and pull it off - Open the isolating valve on the bubbling line - The output voltage reaches 0.5 Vdc ± 0.006 : check for possible overpressure in the tank; the output voltage doesn't change : replace the PCB (see 5.6) - Bubbling line obstructed - Clear the bubbling line by service valve if present (see MI5006 4.4.2) or by injection of compressed air after closing the isolating valve on bubbling line CT801-SI, CT801-TA Maintenance Manual 9

Observation Cause Remedies Output current lower than expected value related to the product level in the tank, on CT801-SI Output current upper than expected value related to the product level in the tank, on CT801-SI - Voltage on terminals should be at least 12 Vdc - Pressure staying in the sensor : remove the electronic PCB with sensor by unscrewing the 4 screws, and pull it off - If lower, check the power supply and the voltage drop of the Zener barrier and/or the indicator system load, acc. to the diagram in MT5006 5.3 - The output current reaches 4 ma ± 0.05 : continue with the hereunder causes; the output current doesn't change : check the calibration (see 5.7) - Bubbling flow too low - Check the bubbling flow (see 5.5) - Obstruction of the venting nipple - Obstruction of the line for gas pressure over the liquid surface - Unscrew the venting nipple : if the output current reaches its correct value, replace it (see 5.4) - Check the opening of the isolating valve - Clean the line - Leak on the bubbling line - Check for possible leak on the bubbling line, for instance proceed to a pressure test (see MI5006 6.1) after closing the isolating valve on bubbling line - Pressure staying in the sensor : remove the electronic PCB with sensor by unscrewing the 4 screws, and pull it off - The output current reaches 4 ma ± 0.05 : continue with the hereunder causes; the output current doesn't change : check the calibration (see 5.7) - Bubbling flow too high - Check the bubbling flow (see 5.5) - Obstruction of the venting nipple - Unscrew the venting nipple : if the output voltage reaches its correct value, replace it (see 5.4) - Bubbling line obstructed - Clear the bubbling line by service valve if present (see MI5006 4.4.2) or by injection of compressed air after closing the isolating valve on bubbling line - Low point on bubbling line, with liquid retention - Obstruction of the line for gas pressure over the liquid surface - Check the bubbling line, correct the low point, install a purge (see MI5006 4.2, 4.3) - Check the opening of the isolating valve - Clean the line CT801-SI, CT801-TA Maintenance Manual 10

Observation Cause Remedies Output voltage lower than expected value related to the product level in the tank, on CT801-TA Output voltage upper than expected value related to the product level in the tank, on CT801-TA 5. REMEDIAL MAINTENANCE 5.1 Recommended spare parts - Voltage on terminals should be at least 4.5 Vdc - Pressure staying in the sensor : remove the electronic PCB with sensor by unscrewing the 4 screws, and pull it off - If lower, check the power supply from the TA840 or EM940 Radar transmitter - The output voltage reaches 0.5 Vdc ± 0.006 : continue with the hereunder causes; the output voltage doesn't change : check the calibration (see 5.7) - Bubbling flow too low - Check the bubbling flow (see 5.5) - Obstruction of the venting nipple - Obstruction of the line for gas pressure over the liquid surface - Unscrew the venting nipple : if the output current reaches its correct value, replace it (see 5.4) - Check the opening of the isolating valve - Clean the line - Leak on the bubbling line - Check for possible leak on the bubbling line, for instance proceed to a pressure test (see MI5006 6.1) after closing the isolating valve on bubbling line - Pressure staying in the sensor : remove the electronic PCB with sensor by unscrewing the 4 screws, and pull it off - The output voltage reaches 0.5 Vdc ± 0.006 : continue with the hereunder causes; the output voltage doesn't change : check the calibration (see 5.7) - Bubbling flow too high - Check the bubbling flow (see 5.5) - Obstruction of the venting nipple - Unscrew the venting nipple : if the output current reaches its correct value, replace it (see 5.4) - Bubbling line obstructed - Clear the bubbling line by service valve if present (see MI5006 4.4.2) or by injection of compressed air after closing the isolating valve on bubbling line - Low point on bubbling line, with liquid retention - Obstruction of the line for gas pressure over the liquid surface - Check the bubbling line, correct the low point, install a purge (see MI5006 4.2, 4.3) - Check the opening of the isolating valve - Clean the line The standard Spare Parts kit (Honeywell Marine code 34173 available for CT801-SI as well as CT801-TA), for one year is described in chapter 6. In case of other spare parts request, see 6, Spare Part list with ordering code. 5.2 Recommended tool kit All hereunder maintenance operations can be easily performed with Honeywell Marine test tool kit, code 29238, including mainly : A calibrated pressure generator A flowmeter All necessary couplings All necessary spanners and screwdrivers. CT801-SI, CT801-TA Maintenance Manual 11

5.3 Air supply filter : replacement a) Close the bubbling line isolating valve, in particular when the CT801 is installed at a place lower than the liquid surface; b) Close the shut-off valve of air supply; c) Slowly unscrew the filter cap (see 2.1) using a spanner 22 mm; let the air supply under pressure flow out; d) Pull out carefully the filter with its spring; e) Replace the filter, together with its spring and gasket; f) Screw the filter cap using a spanner 22 mm. 5.4 Venting nipple : replacement a) Slowly unscrew the venting nipple (see 2.1); b) Screw a new one. 5.5 Bubbling flow adjustment a) Close the bubbling line isolating valve, in particular when the CT801 is installed at a place lower than the liquid surface; b) Slowly unscrew the NPT ¼" plug for flow control (see 2.1); let the bubbling air flow out; c) Screw the NPT ¼"coupling with tube connected to the flowmeter; d) The flow should be 8 to 10 l/h; e) If uncorrect, unscrew the counter-nut of the flow adjustment screw, by using the 7 mm spanner; f) Adjust the flow by unscrewing for flow increase or reverse, by using the 2.5 screwdriver; g) When the value of 8 to 10 l/h is reached, block the screw by tightening the nut-nut; h) Screw the plug sealed with Teflon tape. 5.6 Electronic conditioner : replacement The available hydrostatic pressure ranges are : HYDROSTATIC PRESSURE MEASURING RANGE CT801-SI Type 34052 CT801-SI Type 35445 CT801-TA Code Code Code 0-50/70 mbar 34105-1 35466-1 34106-1 0-70/350 mbar 34105-2 35466-2 34106-2 0-350/1050 mbar 34105-3 35466-3 34106-3 0-1050/2100 mbar 34105-4 35466-4 34106-4 0-2100/4100 mbar 34105-5 35466-5 34106-5 a) Close the bubbling line isolating valve, in particular when the CT801 is installed at a place lower than the liquid surface; b) Close the isolating valve to the gas pressure over the liquid surface if any; c) Close the shut-off valve of air supply; d) Open the electronic module enclosure by unscrewing the cap; e) Unscrew the terminals, pull off the wires, by carefully locating the colors; f) Unscrew the 4 screws and washers (see 2.2) fixing the PCB and the pressure sensor; CT801-SI, CT801-TA Maintenance Manual 12

g) Put in place the new PCB, taking care with the small gaskets and spacers on the pressure inlets of the pressure sensor; h) Screw the 4 screws and washers in the same order; i) Place the wires on the terminals, by respect with the colors; j) Open all the closed valves. 5.7 Electronic conditioner : calibration a) Close the bubbling line isolating valve, in particular when the CT801 is installed at a place lower than the liquid surface; b) Close the isolating valve to the gas pressure over the liquid surface if any; c) Close the shut-off valve of air supply; d) Open the electronic module enclosure by unscrewing the cap; e) Complete the pneumatic and electrical connections as shown on the following diagram. Refer to 2.2 for details of connections and potentiometer locations. Voltage 0.5-2.5 Vdc meter for CT801-TA, on S terminal Pressure copy outlet "R" Current 4-20 ma meter for CT801-SI, in current loop Power Air supply Bubbling line Calibrated pressure generator a) Switch the power supply ON b) Set the pressure to the minimum value of the range; adjust the minimum value of output 4 ma or 0.5 Vdc by moving the potentiometer marked "Z"; the tolerance is ± 0.3 % of the range; c) Set the pressure to the maximum value of the range; adjust the maximum value of output 20 ma or 2.5 Vdc by moving the potentiometer marked "S"; the tolerance is ± 0.3 % of the range; d) Come back to g) in order to check the Zero value; e) Come back to h) in order to check the full Scale value; f) Compare in 5 points of the range, the generated pressure with the measuring signal 4-20 ma or 0.5-2.5 Vdc, according to the operating range explained in the chapter "Operation" in the Technical Manual MT5006. g) After calibration, reassemble, seal the removed connections with Teflon tape and open all the closed valves. CT801-SI, CT801-TA Maintenance Manual 13

5.8 Overpressure protection valve : check a) Close the bubbling line isolating valve; b) Close the isolating valve to the gas pressure over the liquid surface if any; remove the connection on the CT801 to cancel any present pressure; c) Close the shut-off valve of air supply; d) Connect a manometer on the inlet for pressure copy, marked "R" (see 2.1); e) Open the air supply isolating valve; f) Let the pressure increasing seen on the manometer; g) The manometer indication should stop increasing at the pressure range + 200 mbar (range 70 mbar) to 500 mbar (for other ranges); h) If the manometer indication doesn't stop increasing, stop the test, and ask for repair to Honeywell Marine, using the Return for Repair Form; i) Reassemble, seal the removed connections and open all the closed valves. CT801-SI, CT801-TA Maintenance Manual 14

6. SPARE PARTS LIST Two kits are available : The Maintenance kit includes the parts to be replaced yearly (see 3.3). The Honeywell Marine code is 34382; the relevant items are listed in italic bold characters in the table on the following page. A Spare Parts kit includes the main parts for general repair. The Honeywell Marine code is 34173. The relevant items are listed in bold characters in the table on the following page. In case of other spare parts request, refer to the ordering code in the Spare Part list. CT801-SI, CT801-TA Maintenance Manual 15

Item Description Code Quantity in Maintenance kit Quantity in Spare parts kit 1 O-ring 4.00 x 1.00 34055 2 2 O-ring 6.75 x 1.78 952100 2 3 O-ring 2.60 x 1.90 461099 2 4 O-ring 4.47 x 1.78 958051 1 5 Equipped intermediate diaphragm 462789 1 6 Spring 13 x 17 x 23 458381 1 1 7 O-ring 17.17 x 1.78 919301 1 1 8 Filter 406358 1 1 9 Lower gasket 462849 1 10 Equipped valve and rubber 400750 2 11 Equipped lower diaphragm 462790 1 12 O-ring 5.70 x 1.90 936514 2 13 Nut M4 935215 1 14 Adjustment screw 462882 1 15 O-ring R000 936500 1 16 Equipped valve 406259 1 17 O-ring 33.05 x 1.78 952104 1 18 O-ring 50.52 x 1,78 461106 1 19 Equipped upper diaphragm 462792 1 20 O-ring 75.87 x 2.62 917007 1 21 Rubber gland BV2/1 34191 1 22 Rubber gland BV2 966666 1 23 Venting nipple M13651 1 1 24 Spring 461036 25 Valve 461083 26 Spring 400794 27 Spring 408111 28 Screw CHC M4 x 50 958050 29 Screw CHC M4 x 10 935906 30 Spring 411576 For the electronic conditioner, refer to 5.6 CT801-SI, CT801-TA Maintenance Manual 16

7. INFORMATIONS 7.1 Request for Service form The target is : help us to help you! Despite the Troubleshooting guide and the Repair Procedures, in case of spare part need or of request for Service, the form in annex A needs to be fulfilled and transmitted by fax to Honeywell Marine. This will help us to confirm the nature of failure and remedies, for better service. This report will be requested before any other intervention. 7.2 Return for repair form The Return for Repair form in annex B needs to be fulfilled and transmitted to Honeywell Marine together with the defective equipment in purpose. This will help us to identify the defect and the action to carry out, for better service. 7.3 Reference of Honeywell Marine Customer Service Address : Honeywell Marine 9, rue Isaac Newton Z.A. Port Sec Nord 18000 BOURGES Telephone : +33 2 48 23 79 18 Fax : +33 2 48 23 79 02 E-mail : service.marine@honeywell.com CT801-SI, CT801-TA Maintenance Manual 17

8. PERSONAL NOTES CT801-SI, CT801-TA Maintenance Manual 18

APPENDIX A CT801 SERIES - REQUEST FOR SERVICE Vessel :... Hull number :... Owner or Shipyard :... Transmitter P/N :... S/N :... 1) Description of trouble, with read values, etc : 2) Result of troubleshooting item applied, observations : 3) Carried out remedies : 4) Requested spare parts : NAME : DATE : QUALITY : SIGNATURE : CT801-SI, CT801-TA Maintenance Manual 19

APPENDIX B - TA3840 SYSTEM / RETURN FOR REPAIR FORM Formulaire S-SOP-FR1F-SRV-1-F01 Honeywell Return Material Authorization Form Ship to: Est. shipping date: Honeywell Marine 9, rue Isaac Newton ZA Port Sec Nord 18000 Bourges (FRANCE) Handled by: RMA #: Company name E-mail: Tel: +33 (0) 248237918 Fax: +33(0) 248237902 Return shipment details RMA # only issued by Honeywell Marine factory. Customer order ref # Customer order details Attention Quotation required? Yes No Adress Warranty claim details Postal code / City Warranty claimed? Yes No Country Reason of claim: Phone / Fax Original order #: E-mail Delivery date: Return shipment by: Claim acceptance Yes No End user info End user same as Return shipment consignee? Yes No If not, provide end user company and description of end use: End user company: End use: Instrument / Item details Instrument description: Model # / Type #: Serial #: Part #: Description: Installation date: Commissioning date: Problem description: Repair Replacement Model # Change Goods are returned for: (Re) Calibration Other: Return on Advanced Replacement Upgrade / Modify Required modification/ calibration/change/etc.: Application details (applicable for wetted parts only) Product: Operating temperature: Operating pressure: min.: normal: max.: min.: normal: max.: By signing and returning this RMA Form I confirm that the equipment has been cleaned and decontaminated in accordance with good industrial practices and in compliance with all regulations. This equipment poses no health or safety risk due to contamination. If applicable, I attach corresponding International Chemical Safety Cards for the media the equipment was exposed to. Also I agree that by returning above mentioned goods I will at least be charged with examination costs of EUR,,,,, per item. Name: Signature: Department: Date: In order to avoid delays please ensure that all applicable fields are completed. Completed forms (one per instrument, spares can be itemized on a separate list) to be mailed to service.marine@honeywell.com. Equipment to be sent to above mentioned "Ship To: " address with a copy of the completed form(s) on the packaging. Do not send equipment before receiving a RMA number. CT801-SI, CT801-TA Maintenance Manual 20

Honeywell Marine SAS 9, Rue Isaac Newton 18000 Bourges France Tel + 33 (0) 2 48 23 79 01 Fax + 33 (0) 2 48 23 79 03 E-mail: contact.marine@honeywell.com www.honeywellprocess.com MM5006E-rev04-ENG February 2013 2013 Honeywell International Inc.