DOUBLE SAFETY: NO PANIC, NO BACTERIA

Similar documents
K13.12 FACE FIXED PANIC EXIT DEVICE K13 DOORS

INSTALLATION INSTRUCTIONS PUSH BAR PULLMAN PANIC BOLT DEVICE TO EN 1125 : 2008

DICTATOR "DIREKT" Gate Closer

DICTATOR "DIREKT" Gate Closer

STEELWORX Residential

FLUID - Panic Exit Device

Manual winch MANISTOR 100 and 200

CHAIN LINK FENCE GATE

Hardened Steel Washers

Overview (key points)

Extension Platform. Base Platform. Crossover. Exit railing. Exit Railing

ARCA cabinet NEW. High performance polycarbonate cabinet. Protection in demanding environments

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25

DEADBOLT SETS, MECHANICAL FEATURES

CFSW. Hinges with built-in safety multiple switch

SPOKES & NIPPLES FOR BICYCLE 2017

PTC INSTRUMENTS 2301 Federal Ave Los Angeles CA Phone: Model 500 Automatic Operating Stand Type 3

DEADLATCHES LK-2100 SERIES ASSEMBLY DETAILS LK R-RH

Size : Ends : Min Temperature : Max Temperature : Materials : Cast iron body

F13.11 PARALLEL HINGES F13 PROJECT-OUT WINDOWS AND TOP HUNG WINDOWS

TECHNICAL MANUAL. COPRA Anchoring Coupler. For Smart Bolted Connections

IZH-53M AIR PISTOL. Certificate

SERIES A24 RAISED RIB

3M InCa Individual Cross-Connection Cabinets

8MAY15 US RACK, Inc Falcon Drive, Madera, CA

It allows you to. is the Best Option. More information at

VENTILATOR OPTIONS. Please visit our web page to view all the available options and for a specification.

H11.13 PIVOTS SERIES 490 H11 HORIZONTAL AND VERTICAL PIVOT WINDOWS

Important Note: Tighten lock nuts so the support tubes still swing freely see figure 2. There must be 1 2 threads of bolt past end of lock nuts.

Reduce pressure zone device suitable for high and medium hazard rated applications BSP screwed connections

CR Series. Special doors for clean room application

INDUSTRIAL HOSE REEL suitable also for out-door workplaces. Made in Italy

VALVCHEQ BACKFLOW PREVENTERS FIGURE RP03

Materials : Stainless steel ASTM A351 CF8M

OPERATION AND INSTRUCTION MANUAL Beam Trolley Model: BTA012N

A soft sealed atmospheric safety valve with large flow capacity and soft seat tightness for steam condenser and turbine applications

PRODUCT TESTING REPORT

Name of product: Gripper for vertical façade FTV panels Types: PVF (60, 80, 100, 120, 133, 150, 172, 200 and 240 mm) INSTRUCTIONS FOR USE

TRAVSMART permanent single-cable horizontal lifeline system

PRODUCT CARD WALL MOUNTED FIXED BASKETBALL CONSTRUCTION PROJECTION: FROM 1,00 TO 2,25 M

WHERE THERE S A WINCH, THERE S A WAY!

September 2016 File:- Maintenance-3

[Instruments for vacuum measurement, checking and adjustment] 3

LAD-SAF LAD-SAF VERTICAL SAFETY SYSTEM THE ULTIMATE IN FALL PROTECTION

MANUAL SEALLESS STEEL STRAPPING TOOL MODEL A

Technical Data Sheet TI-F50 Locking Units series KFH

PRODUCT CARD WALL MOUNTED SIDE FOLDED BASKETBALL CONSTRUCTION PROJECTION: FROM 1,2 TO 2,45 M

TRUSTED. DURABLE. RELIABLE.

CONDITIONS OF SALE AND WARRANTY

Freshware have a comprehensive range of products for window

Model MTB-ASME Horizontal Bladder Tanks

Horizontal Bladder Tanks

Operation & Maintenance instructions for the Söll Vi-Go type fall protection system with guided type fall arrester

Aluminium & Stainless Steel

Air Saving Valve reduction in 40% air consumption 40% air consumption Air consumption reduction ratio (%) Flow valve Flow valv

Tapped Hole (.375) Tapped hole 15 (.594) (.391±.004) Frame 19±0.2 (.750±.008) 12.7±0.2 (.500±.008) 19±0.2 (.750±.008) R S 4 x Ø 5.4 (.

CFSW. Hinges with built-in safety multiple switch

Mounting and Operating Instructions EB 2558 EN. Self-operated Pressure Regulators. Type Pressure Build-up Regulator

Prewired position switches FA series

CalCheck. Instrument User Manual V1.8

MP-512 Standard Air Rifle. Instruction Manual

OCEAN. Fish Equipment. Quality on the sea

Plummer Block Housings

Fluid Dispensing Systems H O S E R E E L S H O S E S HOSE REELS

ROLLGLISS TOP/R350. Safety and rescue system. Operating and Maintenance Instructions

ELEGANT AND SECURE MODERN BICYCLE PARKING SYSTEMS

A N C H O R T A B S N O R T H W E S T ANCHOR TAB VF. Patented. User Instructions

STAG. Balancing valves Balancing valve with grooved ends DN

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly.

Bike holder with three-point-support for mounting stand

These products are available only in packs of 100 pieces

hockey hockey Integral Weighted Goals Aluminium Goals Fence Folding Goals Premier Hockey Goals Folding Wheelaway Goals

Standard Specifications

Type 4708 Supply Pressure Regulator

Trailer Cargo Anchoring Devices

Premium Series. Economical Price & Reliable Performance. High Quality. Rust-Resistant. Long Life. Tamper-Resistant locking Screw.

1.0 - OPENING AND CLOSING THE DOOR

Forged stainless steel ASTM A182 F316

Pressure switch Type BCP

Slide and Turn System SF35

Model MTB-ASME Vertical Bladder Tanks

Rolled Rotary Ball Screw

TRUSTED. DURABLE. RELIABLE.

Materials : Forged carbon steel A105N

Model MTB-ASME Vertical Bladder Tanks

Workshop Compressors CLASSIC Series

Materials : Carbon steel ASTM A216 WCB

Technical Data Sheet TI-F52 Locking Unit KFHL Certified by Lloyd s Register

NEXT EXIT THE GREAT OUTDOORS POPULATION: EVERYONE

Operating instructions - Translation of the original -

K16.10 EDGE DOOR HANDLES K16 DOORS

INTRODUCING SCHEDULE. Lawful owner Stefano Gollini. The paragraphs preceded by this symbol, if not respected can lead to damages to the machine

Float valves Types SV 4, SV 5 and SV 6

AIR STAPLER MODEL: CSG1C Part No

Vertical Bladder Tanks

Pulley-carabiner that facilitates installation of the rope when pulley is connected to the anchor

Series MX pressure regulators 3/

YOUR TOOLS WILL DROOL.

Innovation and Safety Efficient Solution

INSTRUCTION MANUAL Pressure Relief Device LPT

Transcription:

Panic and emergency exit DOUBLE SAFETY: NO PANIC, NO BACTERIA In line with its attention to safety, ISEO has decided to add this measure to a device which is always present in public environments and in all those places where hygiene and healthcare is a basic requirement: hospitals, clinics, treatment homes, but also child care centres and nursery schools. All ISEO panic and emergency exit with antibacterial coating AntiGerm have obtained the volountary certification ICIM 021AW/0 Therefore, the panic function is enriched with the antibacterial protection, AntiGerm*, whose performance is certified by Padova University Molecular Medicine Department. The antibacterial treatment action is permanent and does not require special maintenance. The constant release of silver ions ensures top efficiency throughout the product life, even in case of surface scratches. * Antibacterical protection for panic exit and accessories (except for Stainless steel/pvd finishes).

Standard EN 1125:2008 All panic exit in compliance with standard EN 1125 are conceived to be used in panic situations. The aim of the standard requirements is mainly to ensure a reliable and safe evacuation through a door making use of the minimum effort and with a single swing of the door, without any prior knowledge of the door device. 6-5

How to read the marking EN 1125:2008 Not suitable for use on fire/smoke doors 3 7 6 0 1 4 2 2 A A Suitable for use on fire/smoke doors 3 7 6 B 1 4 2 2 A A Category of use Durability Door mass Suitability for use on fire/smoke resistant doors People s safety Corrosion resistance Goods security Bar projection Type of bar operation Field of door application Category of use. There is only one category which refers to a high frequency of use where there is little incentive to exercise care, i. e. where there is a chance of an accident and misuse. Durability. There are two grades of durability. grade 6 = 100,000 operations grade 7 = 200,000 operations Door mass. There are three door mass categories: grade 5 = up to 100 kg grade 6 = up to 200 kg grade 7 = over 200 kg Suitability for use on fire/smoke resistant doors. There are three fire/smoke resistance categories: grade 0 = not suitable for fire/smoke resistant doors grade A = suitable for smoke resistant doors grade B = suitable for fire/smoke resistant doors People s safety. There is only one category representing the maximum grade, since panic exit must ensure people s safety. Corrosion resistance. There are two categories as per pren1670: grade 3 = 96 h (high resistance) grade 4 = 240 h (very high resistance) Goods security. Only one grade of security shall be used: the security requirements are secondary to those of safety. Bar projection. There are two categories: grade 1 = bar projection up to mm 150 (large projection) grade 2 = bar projection up to mm 100 (standard projection) Type of bar operation. There are two types of operations: A = panic exit device with push-bar operation (Idea) B = panic exit device with touch-bar operation (Push-Bar) Field of door application. There are three categories: A = single door, double door: active or inactive leaf B = single door only C = double door, inactive leaf only. For further information please refer to EN1125:2008 standard. 6-6

Warning The field of application of these panic exit is limited to following: Maximum door mass Maximum door heigth Maximum door width Temperature interval 200 Kg 2520 mm 1320 mm -10 C +60 C The limits indicated above are identified by EN1125 standard. ISEO Serrature declares that the performances of the and their accessories are in compliance with the requirements of the standard, for doors with mass max. 200 kg, heigth max. 3400 mm and width max. 1500 mm. The effective length (dimension X) of the bar shall be as near as possible to the effective width (dimension Y) of the door for which the device is intended, but never less than 60% (see Fig.1) The door leavers and frames must be made of a material with sufficient rigidity to ensure that any distortions that occur during use can not exceed 5 mm in any position. The device must be fitted to the door leaf using materials that guarantee a tensile strength for each screw of >1,5KN. Products certifications Iseo Serrature has been awarded by Warrington Certification Limited (WCL) the certificate of conformity with EN 1125:08 standard allowing to apply the CE mark on panic exit, compulsory from 01/04/2003. Idea panic exit have already obtained the Voluntary Product Certification by an independent organisation, ICIM, as provided for in EN 1125:08. The ICIM voluntary certification establishes stricter requirements than the CE mark. All the updated certificates can be downloaded from our web site: www.iseoserrature.it Example of product certification 6-7

IDEA Base Inox PVD finish - Inox Code Single package Status Multiple package Min. ord. IDEA Base Inox panic exit device, MODULAR, reversible, PVD - stainless steel finish. Prearranged for double and triple lateral locking. Self-locking steel latch, suitable for fire resistant doors. Stainless steel keep 94100112. Two stainless steel fixing plates 94100042. Prearranged for top-bottom rods. Top/bottom caps. Nylon spacer for external control. Template. Assembly instructions. To be ordered separately: Stainless steel bar 9459** Rods and covers 94100202 for doors mm 2400. Rods and covers 94100302 for doors mm 3400. Pair of steel latches 941020**24 External control 94011002T / 94012002T knob External cylinder 859000859 Microswitch 94100060 Hold-open device 94100070 Electric striker 56800*0 Extended handle follower 947880 Kit of gaskets fire doors 94000030 Steel fixing plate for fire doors 94100040 9414000524 A 1-1 NO 6-8

Accessories PVD finish - Inox 37 Code Single package Status Multiple package Min. ord. 26 47 123 15 Pair of latches with PVD finish for IDEA Base Inox panic exit. Top/bottom vertical locking. Self-locking steel latch suitable for fire resistant doors. Keeps 94100112+94100127. Fixing screws. 9410201524 B 1-1 NO 37 53 133 26 54 Pair of latches with PVD finish for IDEA Base Inox panic exit. Top/bottom vertical locking. Self-locking steel latch suitable for fire resistant doors. Two keeps 94100102. Fixing screws. 9410203524 B 1-1 NO 37 37 26 123 133 26 54 Pair of latches with PVD finish for IDEA Base Inox panic exit. Top/bottom vertical locking. Self-locking steel latch suitable for fire resistant doors. Two keeps 94100102. Fixing screws. 9410204524 D 1-1 NO Stainless steel rods and covers for IDEA Base Inox. One keep for two wings, without spacers. Cap for pushbar lateral latch. For doors with maximum heigth mm 2400 94100202 B 5-5 NO For doors with maximum heigth mm 3400 94100302 B 5-5 NO L 19 Stainless steel horizontal oval bar for panic exit IDEA Base - IDEA Bolt. Length mm 1130 945922 A 1-1 NO Length mm 1330 945932 A 1-1 NO 6-9

IDEA Base Inox: application scheme for single leaf doors 9414000524 9410201524 9410204524 9410203524 945922 L = 1130 945932 L = 1330 94100202 94100302 * * * * * * * * * * * * * 56800** + 5680012 94011002T 94021002 * * * * * * * 94012002T 94100060 94100070 6-10 * = Necessary items ( = 2 pcs, = 3 pcs) = Choose one item only = Optional items ( = 2 pcs, = 3 pcs)

IDEA Base Inox: application scheme for double doors unrebated unrebated 9414000524 9410201524 9410204524 9410203524 945922 L = 1130 945932 L = 1330 * * * * 94100202 94100302 * * * * 56800** + 5680012 94011002T 94021002 * * * * 94012002T 94100060 94100070 * = Necessary items ( = 2 pcs, = 3 pcs) = Choose one item only = Optional items ( = 2 pcs, = 3 pcs) 6-11