Quantification of Contamination Using Quartz Crystal Thickness Monitors

Similar documents
Remote Plasma Cleaning from a TEM Sample Holder with an Evactron De-Contaminator ABSTRACT

INTRODUCTION: EXPERIMENTAL NOTES:

Helium Mass Spectrometric Leak Detection In Large Size Process Plants

The SPI Sputter Coater Handbook

Operating Procedures for Metal Evaporator I

Introduction of Vacuum Science & Technology. Diffusion pumps used on the Calutron mass spectrometers during the Manhattan Project.

Leak Checking Large Vacuum Chambers

DEVICES FOR FIELD DETERMINATION OF WATER VAPOR IN NATURAL GAS Betsy Murphy MNM Enterprises 801 N. Riverside Drive Fort Worth, Texas 76111

BEST KNOWN METHODS. Transpector XPR3 Gas Analysis System. 1 of 6 DESCRIPTION XPR3 APPLICATIONS PHYSICAL INSTALLATION

Lab 3 Introduction to Quantitative Analysis: Pumps and Measurements of Flow

OLED vacuum deposition cluster system Sunicel Plus 400 / Plus 400L (Sunic Systems)

Arizona State University Center for Solid State Electronic Research. Table of Contents. Issue: C Title: Oxford Plasmalab 80plus (Floey) Page 1 of 8

Plasma-Therm PECVD. Operating Characteristics. Operating Instructions. Typical Processes. I. Loading. II. Operating

Both physical and chemical effects come into play either separately or in combination.

Plasma Cleaner. Yamato Scientific America. Contents. Innovating Science for Over 125 Years. Gas Plasma Dry Cleaner PDC200/210/510 PDC610G.

A Journal of Practical and Useful Vacuum Technology. By Phil Danielson

Instruction Manual. Digital Thermocouple Gauge Control Units Models DTC & DTC Models DTC-06M-115 & DTC-06M-230

Fig. 1: Mechanical vacuum gauge (left) and capacitive vacuum gauge (right)

QUORUM TECH 150RES THE FIRST AND THIRD WEEK WILL BE SET UP FOR CARBON COATING THE SECOND AND LAST WEEK WILL BE SET UP FOR GOLD COATING

REPRODUCIBILITY IN OPTICAL THIN FILM PROCESSING PART 1, THE VACUUM AND PUMPING

Cryo-Evaporator Operation

Usage Policies Notebook for AMST Molecular Vapor Deposition System MVD 100

Residual Gas Analysis Systems for Industry

How To Use Getters and Getter Pumps

EXERCISE 2: THE VACUUM SYSTEM

Flow in a shock tube

Standard Operating Manual

UNITY 2 TM. Air Server Series 2 Operators Manual. Version 1.0. February 2008

Issue: H Title: CHA E-Beam Evaporator Page 1 of 7. Table of Contents

ATEX VACUUM PUMPS AND GAUGES CHEMICALLY RESISTANT, OIL-FREE AND SAFE

School of Chemistry SOP For Operation Of Glove Boxes

1.1 Equipment: substrate, wafer tweezers, metal targets 1.2 Personal Protective Equipment: nitrile gloves, safety glasses 1.

High Performance Mass Spectrometers

Investigation of Thermal Effects of CO 2 on Earth-Atmosphere System

Angstrom Dielectric Sputterer Operation Manual

APPLICATION OF A CHANNEL PLATE IN FIELD-ION MICROSCOPY

Usage Policies Notebook for Xenon Difluoride (XeF 2 ) Isotropic Si Etch

Advanced Technology Center. Vacuum Optics. Mark Sullivan December 2, Vacuum Optics 1

Practical approach and problems in in-situ RGA calibration

A NOVEL SENSOR USING REMOTE PLASMA EMISSION SPECTROSCOPY FOR MONITORING AND CONTROL OF VACUUM WEB COATING PROCESSES

OXFORD PLASMALAB 80PLUS (CLOEY)

Mass Spec will not Autotune

Technical Specifications of Hydrogen Isotope Handling and Recovery System

Granville-Phillips Series 370 Stabil-Ion Vacuum Gauge Controller

INSTALLATION AND OPERATING INSTRUCTIONS

Usage Policies Notebook for STS DRIE System

REACTIVE ION ETCHING OF SILICON DIOXIDE USING BOTH OXYGEN AND CARBON DIOXIDE AS GAS ADDITIVES. dames E. Constantino ABSTRACT

Test Facilities Experiment Review

Operating Instructions

1)! DO NOT PROCEED BEYOND THIS MARK

The Principles of Vacuum Technology

PLASMA ENHANCED CHEMICAL VAPOR DEPOSITION (PECVD) SOP OXFORD PLASMALAB SYSTEM 100

Usage Policies Notebook for Parylene Coating System

The Helium Leak Detector

What I have learned about SF 6 gas testing.a Practical explanation

Plasma II (AXIC) Standard Operating Procedure. Revision: 1.0 Last Updated: Feb.6/2013, Revised by Grace Li

Schedule of Requirements THERMODYNAMICS LABORATORY- CHEMICAL ENGINEERING DEPARTMENT

AC : ACCURATE CRYOCHAMBER FOR A SMALL LABORATORY WITH SMALL BUDGET

Standard Operating Manual

Title: Standard Operating Procedure for Dasibi Model 5008 Gas Dilution Calibrator

Quadruple mass spectrometers (transducer type)

Quartz etch process to improve etch depth linearity and uniformity using Mask Etcher IV

Customer Responsibilities

E SC 412 Nanotechnology: Materials, Infrastructure, and Safety Wook Jun Nam The Pennsylvania State University

Generating Calibration Gas Standards

Standard Operating Manual

Air entrainment in Dip coating under vacuum

Leaks, contamination and closed loop control how RGAs make coating processes more profitable

Standard Operating Procedure. For. PVD E-Beam

Chapter 8: Cryo-sorption pumps

Standard Operating Manual

Glove Box with Gas Purification System and Digital Control VGB-6. MTI Corporation

acrolein, acetaldehyde and acetone( cm -1 ); methanol (1306 cm -1 ); ethylene (949 cm -1 ); and isoprene (893 cm -1 ).

Oxygen Contamination

Pressure & Vacuum Measurement. Series 370. Solutions. Stabil-Ion Vacuum gauge and Controller

PRESSURE SENSOR - ABSOLUTE (0 TO 700 kpa)

CHAPTER 5: VACUUM TEST WITH VERTICAL DRAINS

Glove Box Installation Manual

Angstrom E-Beam Instructions. PROCESS CHECKS: the tooling factors of each metal; Ti/Au layer for wire bonding pull test.

[USING THE VITROBOT April 9, Using the Vitrobot

CLARITY STATION. Miniature Transmission Dip Probe INSTRUCTION BOOK. ATS Page 1 of 10 M7922 Issue 1.0

7250 Sys. Ruska Multi-Range Pressure Calibration System. GE Sensing & Inspection Technologies. Features. Applications

Customer Responsibilities

7.9. Flash Column Chromatography Guide

LCLS Heavy Met Outgassing Tests * K. I. Kishiyama, D. M. Behne Lawrence Livermore National Laboratory

BUBBLER CONTROL SYSTEM

Programmable pressure and temperature transmitters PTM/RS485

T EK-COR 1100A. Coriolis Mass Flowmeter. FLOW. Technology Solutions

Detector Carrier Gas Comments Detector anode purge or reference gas. Electron Capture Nitrogen Maximum sensitivity Nitrogen Argon/Methane

LEAP CO 2 Laboratory CO 2 mixtures test facility

Vacuum Science Techniques and Applications Dan Dessau Adv. Lab 2007

OPERATOR S MANUAL Ar-Gone Weld Gas Analyzer

VS Series Leak Detectors for Vacuum Furnaces LEAK DETECTION FOR VACUUM FURNACES

Lab 3 Introduction to Quantitative Analysis: Pumps and Measurements of Flow

Development of Cleaning and Processing Techniques for UHV/XHV at Daresbury Laboratory Keith Middleman

Nordiko Metal Sputtering System Standard Operating Procedure

2 Switching off ECRIS 3. 4 Acquire Beam Spectrum 4. 6 Vent Instrument Chamber 5. 7 Pump down Chamber 5. 8 Baking out Chamber 5.

Next Generation Quartz Pressure Gauges

Chapter 13 Selection and Safe usage of cleaning solvents

Inert Air (N2) Systems Manual

Transcription:

Quantification of Contamination Using Quartz Crystal Thickness Monitors Christopher G. Morgan, Mark M. Gleason and Ronald Vane XEI Scientific, Inc. 1755 E. Bayshore Rd., Suite 17 Redwood City, CA 9463 Introduction Hydrocarbon (HC) contamination is a persistent problem for users of electron microscopes (EMs), often leading to image distortion and interference with nanoprobing [1-4]. Quantifying the amount of contamination present by easy, low cost methods has been a challenging problem. The Evactron De-Contaminator (D-C) has been available for contamination removal in EMs since 1999 [5]. The Evactron D-C uses low power radio frequency (RF) generated plasma in order to produce oxygen radicals which clean the EM. The source of the oxygen radicals is an oxygen containing gas (usually air) which is introduced into the plasma through a controlled leak. The oxygen radicals chemically react with the HCs to form volatile oxidation products such as H 2 O, CO and CO 2. These volatile compounds can be pumped out of the EM chamber. The efficiency of the Evactron process can depend on several parameters; the pressure measured in the plasma, the power of the RF generator, the location in the chamber of the cleaning, and whether there are any obstacles between the plasma and the area to be cleaned. As of yet, no studies have been done to determine what effect these parameters have on the efficiency of the Evactron process. It is very easy to qualitatively demonstrate the efficiency of the Evactron process; a light HC deposit can be removed from a mirrored surface within minutes. However, a quantitative method of determining the efficiency of the Evactron process is needed. Here at XEI Scientific, we have decided that using a quartz thin film thickness monitor (QCTM) is the best method for monitoring the efficiency of the Evactron process. Quartz crystal thin film thickness monitors are a standard technique for measuring the vacuum deposition of thin films and are available from many manufacturers [6]. Experimental Set-up and Equipment The experimental set-up is shown in the picture below (Figure 1). The size of the vacuum chamber used for the experiments is 3 cm diameter and 15 cm in height. It has four KF4 ports equidistant from each other. One of these ports is reserved for the vacuum pump; either an oil pump or a scroll pump was used in this system. The port opposite the vacuum line is reserved for the Evactron D-C Oxygen Radical Source (ORS). The third port has the electronic feedthroughs for the QCTMs, and the last port is used for introducing contamination into the chamber.

Figure 1: Picture of vacuum chamber used for QCTM studies with Evactron D-C QCTM Feedthrough Evactron D-C To Vacuum Pump QCTM Port for loading contamination The signals from the QCTMs are monitored by a thickness monitor (McVac - MCM 16). Two QCTMs can be monitored with this device, and their output can be sent via an RS232 cable to a PC, where a LabVIEW program can record the output as a function of time. A separate vacuum gauge can be used to monitor the pressure inside the chamber. Depositing a Contamination Layer onto the QCTM The following procedure is used to deposit contamination onto the QCTMs. Between 5-7 drops of liquid contamination (typically pump oil supplied by Duniway Stockroom Corp., part # MPO19-1, but flaxseed oil is also used) are placed inside of an 11 cm long vacuum tube. One end of the tube is attached to the chamber, and a leak valve is attached to the other end of the tube. The QCTMs are placed close to the port with the vacuum tube attached. The chamber is pumped down, and its pressure is adjusted to ~.15 mbar using the leak valve. The vacuum tube is heated until a layer of oil ~.5 um is deposited on the QCTMs. A typical trace of thickness gain as a function of time on the QCTMs is shown in Figure 2. The tube is then allowed to cool, and the chamber is opened. Excess oil in the vacuum tube, on the walls of the chamber, and on the mounts for the QCTMs is removed using isopropyl alcohol wipes. Figure 2 Deposit of Pump Oil on Both QCTMs at.15 mbar Thickness Gain (Angstroms) 1 8 6 QCTM #1 4 QCTM #2 2-2 5 1 15 2 Elapsed Time (minutes) 25 3

It should be pointed out that this procedure deposits far more contamination in the chamber than would ever be expected in normal EM operating conditions. The goal of this procedure is not to recreate EM contamination. Instead, it is to insure that enough oil is deposited on the QCTMs so that a series of experiments can be performed with them. Typical Experiment A typical experiment with the Evactron D-C and two QCTMs is run in the following way. One QCTM is placed in the center of the chamber and the other QCTM is placed on the side of the chamber by the port used for loading contamination. Figure 3: Schematic of typical experiment to determine cleaning efficiency of Evactron D-C using QCTMs Thickness Meter Monitor ORS Evactron Controller QCTM1 QCTM2 PC Chamber: Diameter = 3 cm Height = 18 cm To Vacuum Results Behavior of the Contamination on the QCTM When the QCTMs with the oil deposit are placed in the vacuum chamber and allowed to be pumped on, the oil is removed through evaporation. The rate of removal is rapid at first, but then slows down to an almost negligible rate, as seen in Figure 4. When the Evactron D-C is turned on, the rate of oil removal increases again.

Figure 4: Here is a measurement of oil thickness loss versus time using a single QCTM. Ambient chamber pressure was.6 Torr. Blue triangles ( ) show thickness loss before Evactron process started. Red squares ( ) show thickness loss after start of Evactron process. Power of RF generator was at 14 W. Thickness Loss (Å) 8 7 6 5 4 3 2 1 5 1 15 Time (minutes) If, on the other hand, the Evactron D-C is turned on shortly after a fresh layer of oil has been deposited, there is an initial increase in the thickness, as seen in Figure 5. Our interpretation of this behavior is that when the Evactron process has started, the oil in the contamination layer begins to be oxidized by the radicals produced in the plasma. However, there is an induction period during the initial Evactron D-C activity. During this period the oxygen radicals are incorporated into the oil layers, causing an increase in the thickness of the oil layer. Note also the delay between the minima in the center QCTM signal and the side QCTM signal, due to the longer time needed for the oxygen radicals to reach the side QCTM. Figure 5: Initial activity seen during Evactron D-C cleaning immediately after depositing ~.65 um pump oil onto both QCTMs. The chamber pressure is set to.4 Torr and the RF power is set to 14W. Blue triangles ( ) show thickness loss of the center QCTM, while red squares ( ) show thickness loss at the side QCTM. Note the induction period for both traces, during which the thickness of the contamination layer increases due to incorporation of oxygen radicals into the layer. Thickness Loss (Angstroms) 3 Center QCTM 2 Side QCTM 1-1 -2-3 -4-5 1 2 3 4 5 6 Elapsed Time (minutes) Once enough oxygen radicals reach the surface and are incorporated into it, the oil layer can be turned into volatile compounds and removed. This removal, or thickness loss, occurs at a steady rate, as seen after 1-15 minutes elapsed time in Figure 5. The thickness loss rate is repeatable under the same Evactron D-C operating conditions. We have been able to demonstrate that a quartz crystal thickness monitor can be used to measure the rate of decontamination by the Evactron process. The monitor can now provide a measure of Evactron process efficiency as a function of chamber pressure, RF power, and location of surface to be cleaned relative to the Evactron process and the pump. We can also determine the effect on

the Evactron process on what gas mixture is used in the plasma and whether there are any obstacles, such as collimators, between the surface to be cleaned and the Evactron D-C. References [1] A. Vladár, M. T. Postek, and R. Vane, Contamination. Proc. SPIE (21) 4344:835-843 [2] M. T. Postek, SCANNING (1996) 18:269-274 [3] N. Sullivan, T. Mai, S. Bowdoin and R. Vane, Microsc. Microanal. 8 (Suppl 2) (22) 72CD [4] L. Reimer, SPIE Opt. Eng. Press, Volume TT 12 (1993) [5] http://www.evactron.com/index.html [6] Milton Ohring, The Materials Science of Thin Films, 2nd edition, Academic Press, 21