Model SOP Standard Operating Procedure

Similar documents
Direct attack. 1 Introduction

DISCLAIMER TSS is simply providing current information so you can make sound tactical decisions.

Introduction Volume & Area Based formulas Figure 1

BASIC FIRE SCHOOL VENTILATION, SALVAGE & OVERHAUL

TACTICAL VENTILATION Graeme Bowser, Tyne & Wear Fire Brigade, U.K.

SITUATIONAL AWARENESS, DISORIENTATION and IMPROVING FIREFIGHTER SURVIVAL AT STRUCTURAL FIRES

Chapter 16 Test. Directions: Write the correct letter on the blank before each question.

Ultra-High Pressure Firefighting: The Fastest Attack

Ventilation Practices and Evidence-Based Research. By: John Paul Jones, Fire Chief KCKFD

Dräger Swede Survival System Phase 1 Flashover Development Observation

Special Edition. Back To Basics. Search Operations. A Review of the Basics of Fireground Search

Chapter 1 FF I Orientation and Fire Service History

Examiner s Report March 2013

What is air track? 1 Introduction

13 Search and Rescue

SUBJECT: RAPID INTERVENTION CREW (RIC) SOG DATE ADOPTED: OCTOBER 18, 2012 REVISED: PAGES: 7

CFBT LEVEL II COURSE INFORMATION SHEET

PERFORMANCE CRITERIA AND INSTRUCTIONS

Presenter s Notes. Before darkening the room, offer a welcome and an overview. Begin by introducing the program and its topic:

Level 3 Certificate in Fire Science, Operations, Fire Safety and Management (All Examinations)

North Carolina Fire and Rescue Commission Live Fire Audit Form

ESCONDIDO FIRE DEPT TRAINING MANUAL Section Truck Module Page 1 of 5 Utilities Gas Emergencies Revised

Idaho Fire Service Technology Fire Fighter II

Wilson County Emergency Management Agency 110 Oak Street Lebanon, Tennessee 37087

ESCONDIDO FIRE DEPT TRAINING MANUAL Section DRIVER OPERATOR Page 1 of 14 Hydraulics Revised

To establish a guideline for the safe and effective deployment of apparatus, personnel, and resources at the scene of structural fires.

Structural Firefighting Review: Fire Attack

SMOKE CONTROL USING POSITIVE PRESSURE FANS

Turning robots into thinking firemen

Township of Cumru Fire Department 03/12/2008 Standard Operating Guidelines Page: 1 of 8 Section 15.05

APPLCATIONS OF POSITIVE PRESSURE VENTILATION DURING AIRPORT AND ARFF INCIDENTS. Leroy B. Coffman III, Tempest Technology Corporation, USA

There are three fuelling systems which use LNG/CNG and which may be found in vehicles today:

First Responder Beware

CFBT LEVEL I COURSE INFORMATION SHEET

USER S INFORMATION MANUAL

Skill Sheet 17-I-2. Attack a structure fire above, below, and at ground level Interior attack. (NFPA 1001, , )

ESCONDIDO FIRE DEPARTMENT TRAINING MANUAL ENGINE MODULE HOSE PAGE 1 OF 24 Attack Hose Lays Revised

17 15 NOVA SCOTIA FIRE SERVICE TRAINING EXTERIOR LEVEL (PHASE 2)

ESCONDIDO FIRE DEPT TRAINING MANUAL Section Truck Module Page 1 of 8 Search and Rescue Basics Revised

A PARTIAL GUIDE TO MCFRS SAFE STRUCTURAL FIREFIGHTING POLICY. Section II Rapid Intervention

Manitowoc County MABAS Division 128 Rapid Intervention Policy

Tools, Techniques and Tactics (3T) in Combination for Firefighting

PBCFR Reserve Battalion Combat Skills Check Off

ALAMEDA COUNTY FIRE CHIEFS ASSOCIATION

All Candidates are required to supply their own steel toed boots. (No low angle cut style boots are permitted)

City of Greencastle Fire Department

SCENARIO 18 Leak on Intermodal Pressure Tank Container

INSTRUCTOR GUIDE TOPIC: STOPPING UNSAFE PRACTICES LEVEL OF INSTRUCTION: TIME REQUIRED: THREE HOURS MATERIALS: APPROPRIATE AUDIO-VISUAL MATERIALS

RAPID INTERVENTION CREW TEAMS

TOPIC: EVALUATING FIREFIGHTER PROFICIENCY MATERIALS: PERSONAL PROTECTIVE CLOTHING AS REQUIRED FOR EACH EVOLUTION

FIRE CHIEF S ASSOCIATION OF BROWARD COUNTY

2017 Volunteer Week - Course Descriptions

the Fire Tetrahedron Identify the relationship of the concentration of

**ALL SHADED SKILLS MUST BE SIGNED OFF BEFORE LIVE FIRE TESTING MAY OCCUR**

The term MAYDAY typically will be used in the following situations:

COMMISSION ON FIRE PROTECTION PERSONNEL STANDARDS AND EDUCATION COMMONWEALTH OF KENTUCKY FIREFIGHTER 2 COMPETENCY EVALUATION

TEMPLETON FIRE DEPARTMENT

FIRE LOGISTICS AND MATH EDUCATION A Rumpke Public Outreach Program

Guidance on room integrity testing and its interpretation

IFE Level 3 Diploma in Fire Safety and Fire Science. Unit 6 Fire Service Operations and Incident Command

Only equipment issued by the Sarasota County Fire Department shall be used for self rescue.

Gulfstream Natural Gas System

Talk Science Professional Development

FIREGROUND HYDRAULICS

UNIT OBJECTIVES Upon completion of this unit of study, the student should be able to:

Responding to Natural Gas Pipeline Emergencies

Apparatus Operator Refresher Training Program

MSDS Interspiro Spiroscape EEBD (compressed breathing air)

Emergency Water Injection /28/2017 updated 07/21/2017

===============================================================

NATURAL GAS RESPONSE SOG

IFE Level 3 Diploma in Fire Safety and Fire Science. Unit 6 Fire Service Operations and Incident Command

GENERAL STRUCTURAL FIRE OPERATIONS

Rapid Intervention for Engine Companies. LA County Fire Department

CLEARWATER FIRE ACADEMY

Humberside Fire and Rescue Service

Wayne County Community College District

EMS Fire Scene Operations

CNG/LPG Vehicles Emergency First Response Guide

EMERGENCY RESPONDER INFORMATION

STANDARD OPERATING GUIDELINE

FIRE FIGHTER II - SKILLS PERFORMANCE SHEET

Engine Compan. pany y Operations. Firefighting and Emergency Operations Volume I - General Firefighting Procedures Book 2 Issued November 2003

Number of Pages: 13 SOG Number: 1-13

Lumbar Pack Safety System: Webbing

TABLE OF CONTENTS PART 11 - FIREFIGHTING

FRS 105. Firefighters Intermediate Skills II. 45 clock hours 3 credit hours

Confined space entry. In defining a permit-required confined space, the standard lists the following characteristics:

Striking an underground pipeline or underground electric line can lead to serious injury or death. If you hit either, call (800) , even if

BASF Flash Fire FRC Assessment Tool

Fire and Rescue Operations Chapter 03 2 In, 2 Out and Rapid Intervention March 2009

Enabling Objectives (EO): EO Identify certain practices that could be considered unsafe and result in injury or death.

West Metro Fire Protection District

ASTATT10 Carry out air tightness testing on large and complex, high rise and phased hand over zonal buildings

Black Sunday New York City: January 23, 2005

Yakima County Fire District 12 Standard Operating Guidlines SOG 2-11 Interior Structure Firefighting

Fire Safety Hot Work Permit Policy/ Procedures

Instructions. To complete this independent study program, view the entire program, advancing through each slide by pressing the enter key.

SAFETY BULLETIN 01/05

TRAINING CENTER USAGE FORMS & REMINDERS

Transcription:

Model SOP Standard Operating Procedure Firetactics.com SOP 3/Version 1/2008 3. ENTRY PROCEDURES INTO FIRE-INVOLVED COMPARTMENTS Sections 1. Purpose 2. Objectives of compartment entry 3. Residential compartments 4. Larger commercial units 5. Large Volume Structures (LVS) 6. High rise Buildings 7. Door Entry Tactics 1. Purpose The following bulletin serves as a training document that covers compartment entry techniques. The methods used are not universal but are proposed in a way that demonstrates entry techniques will vary according to fire conditions. In some situations a ventilation controlled fire will exist with little flaming but high amounts of combustion products accumulated that are possibly in a fuel rich state. In other situations the flaming fire may be very post flashover and very intense. On occasions, an opposing wind may enter the building and create untenable conditions for firefighters. In all cases the control of fire conditions will rely on an effective compartment entry technique, adequate flow rate and a coordinated venting strategy. 2. Objectives of Compartment Entry When arriving first on scene at a structure fire, the fire conditions may present themselves in many ways. For example, the building may be sealed closed and no sign of fire may be apparent from the exterior, although there may be a smell of burning in the air. It may be that a window is open or has failed through heat with large amounts of smoke issuing. Alternatively, the fire may be post flashover in some (or all) parts of the building and flames may be issuing from one or more openings. The fire may also have extended to other compartments, voids or roof spaces. In some cases the fire will involve small residential compartments of 20m 2 or entire apartments to 100m 2 or more. In larger commercial units floor spaces floor areas may range anywhere from 250m 2 to 1000m 2 whilst larger industrial warehouses or large volume superstores may exist in excess of 10,000m 2. 1 SOP 3:Version 1/2008

A wide range of smoke and fire conditions may exist but quite simply, we are looking to differentiate between (rough guide) 2.1 Smoke & Fire Conditions Indicators o Light smoke from an early stage pyrolyzing fire o Brown smoke from a fire in a ventilation controlled state o Black smoke from an under ventilated fire o High volumes of smoke from a heavy fire load o Fast moving smoke demonstrating a fire that is rapidly progressing towards flashover or some other event The overall purpose of using compartment entry techniques is to take control of the fire s development by preventing the formation of fast moving smoke where an air exchange is taking place from the point of entry to the fire. Also, to cool fire gases near the ceiling and adjacent to the point of entry in an effort to reduce flashover or auto ignition potential. If we are able to take control of the fire from this very early stage, the prognosis for an effective outcome is much better. In all situations we should close doors where possible and isolate fire development as air flow in freely to feed the fire. We should do this during the first vital moments as we set up our attack. As we advance inside a structure we should close all doors as we pass them in order to zone down the structure into manageable compartments. This will have the effect of cutting off fire travel behind us as well as reducing the impact of any ignitions of fire gases in the overhead. Look at the floor plans on countless NIOSH fatal fire reports and note where fire fighters entered without using a door entry procedure; without zoning down the fire by closing doors as they passed them, and see how many fire fighters were then killed by sudden fire escalation that came from behind or below them. The simple action of closing a door as they passed it may well have saved their lives. 3. Residential Compartments Smaller residential units or houses allow us to make use of finely divided water droplets, in a fog spray pattern, to control the gases as we gain entry to the structure and fire compartment itself. If our droplet pattern is effective with 6 7 bars and at least 500 LPM (125 GPM) at the nozzle we can apply short bursts of 2 3 seconds duration at the ceiling as we just crack the door a nozzle width to get the stream inside. During this operation, take a second to look in the door through this tiny opening. What do you see? Observe the smoke. What colour is it? How fast and in what direction is it moving? Is the smoke under pressure to get out or is it sucking air back in? Maybe there are even signs of fire. Within 4 5seconds you will have applied a decent amount of water in through the opening and got a look at the conditions. Close the door and count to ten! Let the water work in the gases as it vaporizes. Then repeat the process and depending on conditions, you may want to close the door once more or make entry. 2 SOP 3:Version 1/2008

This brief 15 30 second approach is controlled. It allows you and your crew time to ensure you are together, working as a team. Take a look around during this period. Read the conditions but also get a feel for the layout of the structure. How many floors? Where are the windows? Where are the stairs likely to be? Is the fire at your level in the front of the house or the rear? Advance in and continue to cool gases in the overhead with short bursts of water fog. By using very small amounts of water you will effectively steam the atmosphere without steaming your crew. However, where the smoke and gases are so hot that you are being enveloped in steam, even when using just small amounts of water, we may need different tactics! Fire Stream Applications - 3 3D Gaseous-phase cooling Old Fire Stream Applications - 2 Direct attack at Shielded Fuel-phase 3D Fire-fighting Tactical Applications Fire2000.com 3D Fire-fighting Tactical Applications Fire2000.com By using brief bursts (2 3 second cycles) of a straight stream bounced off the ceiling you will gain some cooling effect in the overhead as the water vaporizes and the stream will break up into large droplets that may reach the firebase itself. In doing this, direct the hose stream further away from you at a 30 40 degree angle to the floor. Assess the effects and advance on. 4. Larger Commercial Units Where floor area increases, so generally does the fire load. In effect you may need greater amounts of water so the 500 LPM (125 GPM) stream may become underpowered. Remember the basic flow formula of A x 6 which states that for every square metre of fire involvement you ll need 6 LPM to deal safely and effectively with a developing fire. This is a European formula but it matches almost exactly with the US equivalent, providing you recognise that the NFA formula is for the attack line AND a secondary support hose line combined (the resulting NFA flow rate should be divided by 2). In large commercial outlets the primary attack line should flow a greater amount, in the realms of 750LPM (200 GPM) according to the levels of fire development and involvement. However, the door entry procedures remain the same and remember to zone down the compartments once inside. 5. Large Volume Structures Similar to large commercial outlets, these lightweight steel clad structures that may have floor areas in excess of 10,000 m 2 can present tremendous challenges and dangerous hazards to firefighters. The power laws of fire spread demonstrate that these fires can rapidly develop and double in size every 30 seconds! Such fire spread is often non too obvious as the high ceilings take the smoke layer away from the floor, but in those dangerous gases at high level we have a recipe for disaster. Suddenly the fire may cause a rippling effect in the smoke layer as it bounces up and down. This is where there is conflict with air rushing in to feed the fire and small bursts of flaming gases high up near the ceiling that aren t able to sustain themselves due to the heavy rich mix of gases existing in the overhead. However, this effect in the layer is signalling an impending event of rapid fire progress. When this occurs firefighters will become disoriented as the smoke layer suddenly drops to the floor, forced there by the expanding gases near the ceiling. This expansion is caused by a fire gas ignition and whilst the firefighters may well survive this stage, they will end in a state of panic as they become 3 SOP 3:Version 1/2008

lost in the dark smoke, unable to escape from the super heated conditions. Their air will run out in a few short minutes as their breathing rate increases dramatically. In these buildings there must be strict command and control and risk assessed strategies employed. Refer to SOP 1:2008 (Tactical Deployment) for further details. SECURING TEAM SAFETY Fire2000 Paul GRIMWOOD SECURING TEAM SAFETY Fire2000 Paul GRIMWOOD Don t get caught out with inadequate flow rate and an uncoordinated entry to fire involved compartments 6. High rise Buildings Fires involving high rise compartments are generally of two distinct types 6.1 High rise Fires o Residential high rise tower blocks with common hallways between apartments o Office and commercial buildings, sometimes with large open plan floors In the first case we are faced with a situation typical of a residential fire at ground level, except there will be a clear time lag between entering the building and operating on the fire floor. There will also be communication problems where a serious fire involves large numbers of staff and resources onscene. In the second situation we are faced with a severe problem where fire threatens to develop beyond the control of a fire fighting force, where sprinklers are not installed, as flames spread up the outside of the structure. In both cases there is potential for exterior winds, which are greatly magnified in their velocity and strength at height, to create blow torching effects in common hallways servicing apartments and across open plan office floors. These every intense fires can lead to totally different door entry procedures than those used at ground level. In a high rise fire, flow rate at the nozzle is more important than high pressure creating finely divided droplets in a fog pattern. We need to flow large amounts of water at these fires and therefore our attack methods are different. The rising main standpipes and length of hose runs may not support adequate pressures at the nozzle. Therefore we need to revert to smooth bore nozzles to ensure minimum flow rates of 500 LPM for residential fires and 750 900 LPM for open plan office fires. Without these flow rates we are fighting an uphill battle against the flames, literally! If you analyse fire loads and wind effects together against needed flow rates it soon becomes obvious why firefighters are so often beaten back by these fires. 5.1 High rise Fires Compartment Door Entry Procedure o Adequate flow rate is the most important requirement o An 80m 2 apartment requires a minimum of 500 LPM on the primary line o Where exterior wind effects are blow torching the fire the first two lines might have to share 1000 LPM (270 GPM) between them this is an absolute minimum! o The best way to ensure these flow rates is to have a smooth bore on the primary attack line, supported by a spray nozzle on the secondary support line 4 SOP 3:Version 1/2008

7. Door Entry Tactics o The door entry is achieved in a similar way as above, using 2 3 second burst cycles o If the entry cannot be gained then a 90 degree high flow spray should be used to advance in and the smooth bore should follow in support o Fast developing open plan office fires may require 950 LPM off the first in nozzle! o This may have to be deployed into the compartment from the entrance lobby/hallway due to heat and fire conditions pushing out 7.1 When gaining entry to a compartment where fire is suspected o If open, close the door to control any inwards air flow feeding the fire o Door entry requires two firefighters one on the door/one on the nozzle o Do not open the door until the attack hose line is effectively charged with water o Kneel or crouch down by the door and use the door to protect you from the fire o If the door opens away from you use a strap or rope tied to the handle to control the door opening o Force the door and open it just enough to get the nozzle tip inside o Make observations on the smoke volume, direction colour and velocity o Look for fire and any occupants just inside, through the 150mm (6 ) opening o Burst a 2 3 second application of water fog up into the overhead inside o Observe the effects and close the door o The entire evolution should take around 10 seconds o Wait for 10 seconds and repeat the process again o Be calm and controlled about this and use the time to set your crew o If conditions permit advance inside on completion of the second evolution o By now you will have been at the door for around 30 seconds and the interior should be steamy on entry o As you advance in, close all doors as you pass the in a effort to zone down the structure o Continue to utilize bursts of water fog on a 30 50 degree fog pattern to cool fire gases in the overhead o A secondary support hose line should be left waiting at the entry door with crew o The nozzle man of this line should control the opening of the door, closing it down to reduce air in flow or opening it up to raise the smoke layer, communicating their actions to the primary attack team and optimising the door opening to best effect o As soon as the first line has made 15m (50 ) into the building the second line should also advance in, attempting to keep 15m distance apart 5 SOP 3:Version 1/2008