IECEx Certificate of Conformity Annexe

Similar documents
IECEx Certificate of Conformity Annexe

IECEx Certificate of Conformity

ABTQ-110 rev 00 (Last review: 28 Aug 12) INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS FOR ABTECH S RANGE ENCLOSURES IECEx SIR U SERIAL No

Operating Instructions

Conductor Bushings Series 8174

Reg No: 1999/027771/07 ACCREDITED AND APPROVED TEST LABORATORY IN TERMS OF ARP 0108: REGULATORY REQUIREMENTS FOR EXPLOSION PROTECTED APPARATUS

INTERNATIONAL ELECTROTECHNICAL COMMISSION (IEC) SCHEME FOR CERTIFICATION TO STANDARDS RELATING TO EQUIPMENT FOR EXPLOSIVE ATMOSPHERES (IECEx SCHEME)

ECP Series Explosionproof Enclosures for OEM Applications. Optimized design, extensive sizes, and fast lead times.

METROSIL CURRENT TRANSFORMER PROTECTION UNIT (CTPU) ENCLOSURES IEC COMPLIANT

Infrared Linescanners

Operating Instructions

Junction Boxes Series 8118

Operating Instructions

E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10. Cable gland Series 8161/7, 8161/8. Installation Equipment and Accessories E10/1.

INSTRUCTION MANUAL Pressure Relief Device LPT

PTB Ex PT Scheme. Procedure Instruction of program Explosion Pressure - Test Round 2017

CABLE ENTRIES IN HAZARDOUS AREAS CORRECT SELECTION, INSTALLATION AND MAINTENANCE

Certificate of Conformity

Single-Phase Pad-Mounted Distribution. Single-Phase Pad-Mounted Distribution Transformers KVA

Further technical information is available on

Check with local zoning official for property line distance requirements.

@h..p. lntertek. IECEx Certificate of Conformity

enclosures to ATEX and enclosures for special custom design (EEx p and NEMA cabinets)

Magnetic level switch type MR783 Instruction Manual

IEC April Authorized Sole Agent : PT. Wisma Niagatama Perkasa. Phone : (031) Fax. : (031)

CATALOGUE // The Fort Vale Range of Equipment to suit Hydrogen Peroxide Tank Specification. Fort Vale Engineering Ltd. 2009

IA CERTIFICATE (Annual review required by MASC covered by an additional letter) (Revision 2- Review & Review)

2-1- Shipping Receiving Lifting Location on Site Installation Stages 6

L230 LED 40 Watt Searchlight

Project: Consultant : MEP Contractor: PREPARED BY: DORMAN SMITH SWITCHGEAR - DUBAI REVIEWED BY CONSULTANT : Page 1 of 15

Manual Power relay SR853

Arran LED Floodlight Luminaire

CFSW. Hinges with built-in safety multiple switch

The evolution of the Ex-proof flame path

ECP Series Explosionproof Enclosures for OEM Applications. Optimized design, extensive sizes, and fast lead times.

3M InCa Individual Cross-Connection Cabinets

OEM Manual MODEL 2305 ECONOMICAL DIGITAL SINGLE CYLINDER SCALE

Certificate of Conformity

INSTALLATION INSTRUCTIONS PUSH BAR PULLMAN PANIC BOLT DEVICE TO EN 1125 : 2008

Installation, operating and maintenance Instructions for Seemag bypass level indicator

enclosures to ATEX and enclosures for special custom design (EEx p and NEMA cabinets)

CFSW. Hinges with built-in safety multiple switch

GV Standard X-Vent. Setup, Commissioning & Installation Guide

44 CE RANGE WATERTIGHT SURFACE-MOUNTING JUNCTION BOXES

NEW TYPE M PRESSURE RELIEF DEVICE

Baying and lifting. Whitepaper

Residential Swimming pools

SPOOL VALVES. pilot operated single/dual solenoid (mono/bistable function) ISO mm - pad mounting body M12 connection

WHEATLEY Series 500 Swing Check Valve

Continental Industries STEEL SERVICE TEES or FAX Visit

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly.

Engineering Data Sheet

Differential Pressure Regulator Type Type 45-6 (0.1 to 1 bar, DN 15) Mounting and Operating Instructions EB 3226 EN

User s Manual EJX/EJA-E Series NEPSI Certification [Option code: /NF2, /NS21, /NS24 and /NS25] IM 01C25A00-12E

Self-operated Regulators Accessories Differential Pressure and Flow Regulators

EXH. Specifications. Descriptions. Min. working pressure MPa

Bulletin Swimming pool, hot tub and spa installations Rules , , , , , and

UHrasonic Sensor VEGASON60 type series SN6*.CI**H***

GAS DISTRIBUTION PRODUCTS TRANSITION FITTINGS

M2 Antenna Systems, Inc. Model No: VLP16

INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS

VERTICAL BLADDER TANK

Flow controller Type ED/CCB311 Instruction manual

PART I. GENERAL REQUIREMENTS FOR PERMANENTLY INSTALLED POOLS, STORABLE POOLS, OUTDOOR SPAS, OUTDOOR HOT TUBS, OR FOUNTAINS

EX-RECESSED CEILING LIGHT FITTINGS

C&G 2395 Exam Paper June Section A-All questions carry equal marks. Answer all three questions. Show all calculations.

Operating Instructions for Intrinsically Safe Pressure Transmitters Series DMG/******** for Hazardous Application in Coal Mining Industry

ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 15 INERT GAS SYSTEMS

HORIZONTAL BLADDER TANK

THIS DOCUMENT SHOULD STAY WITH THE PUMP UNIT AT ALL TIMES!

Gas density monitor With integrated transmitter Model GDM-100-TI

AWWA Pipe Flanges. AWWA C Standard Steel Hub Flanges Class D AWWA C Standard Steel Hub Flanges Class E AWWA C Flange Manufacturer

WHEATLEY WHEATLEY SERIES 500 SWING CHECK VALVE. Installation, Operation and Maintenance Manual

Digital Melting Point Apparatus

Safety Instructions Liquiphant FailSafe FTL80, FTL81, FTL85

RTD temperature probes

Extra wide viewing angle from single indicator lamp. Lenses made from polycarbonate and hardened glass. 10mm Panel Hole.

XCE: Explosionproof Control Enclosures

AWWA C504 COMPLIANT VALVES FROM 3 THRU 108

VERSION 1 SUMP PUMP PIT UNIT KAWAMOTO PUMP ASIA CO.,LTD.

INSTALLATION, OPERATION AND MAINTENANCE GUIDE

PART 3 HULL INTEGRITY AND ARRANGEMENT

BA307C & BA308C Intrinsically safe loop-powered 3½ digit panel mounting indicators issue 9

IECEx Cert f cate of Gonform ty. IECEX SIR ' X issue No.:1 9-e j{ca!ells_tgryi _ lssue No. 1 ( ) lssue No.

GOST R CERTIFICATION SYSTEM FEDERAL AGENCY OF TECHNICAL REGULATION AND METROLOGY CERTIFICATE OF CONFORMITY

Horizontal Bladder Tanks

SG33KTL-M Quick Installation Guide. 1 Unpacking and Inspection

Torque Tube TB300 Digital Transmitters

LTB013EN. Operating Instruction Trimod Besta Level Switch types XA 5, XB 5 for use in potentially explosive atmospheres acc.

Mini-Mac Applicator Specification Sheet Part No (Replaces )

Continental Industries TRANSITION FITTINGS or FAX Visit

4/2 way Pneumatic Solenoid Valve

Vertical Bladder Tanks

VG5 Supplementary instructions

KTM OM-2 SPLIT BODY FLOATING BALL VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

GENERAL APPLICATION NOTES

Assembly instruction. Operating temperature range -60 C +85 C Protection. IP 66, 67, 68 (5 bar)

Model 10E Enviro-Line Environmental Pressurization System Installation & Operation Manual

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI

CA46S Austenitic Stainless Steel Air and Gas Trap DN40 and DN50

Transcription:

for Certificate No.: IECEx TSA 09.004X Issue No.: 1 Equipment description pertaining to Issue 0 of this Certificate: A range of electrical power distribution, control, protection and monitoring equipment that is intended for application to underground coal mining operations and is designated as the AFE00 Series. Detail of the enclosure constructions and the enclosed equipment is described by the manufacturer s design documents. The rating of the enclosed electrical equipment is up to 000 V and up to 150 A. The equipment consists of up to ten types of welded steel plate flameproof enclosures designated as the types AFE01, AFE0, AFE03, AFE04, AFE05, AFE06, AFE07, AFE30, AF E40, AFE90 and AFE47. These types of enclosures differ in their overall dimensions (hence volume) and may be fabricated as separate standalone enclosures or an assembly of enclosures in series sharing internal walls with common top, bottom and rear plates. The enclosure AFE47 is provided for cable protection and situated behind the enclosure. The enclosure AFE47 does not have any terminals and it may produce negligible heat, hence that enclosure is not considered as ex protected enclosure. AFE47 may vary in length depending upon site requirement and numbers of enclosures fed through cables. The enclosures may be fabricated from mild steel (minimum of 50 grade) or stainless steel or a combination of both. Assembly of an enclosure may be mirror imaged to the certification drawings. Access to the interior of an enclosure, or compartment within an enclosure, is via a bolted hinged door or panel. Position of hinges and door openings may vary to suit site requirements. The following are options for the assembly of the equipment: The enclosures, or parts thereof, may be manufactured from mild steel grade 50 or stainless steel of superior grade to mild steel grade 50. Inclusion of any of the certified components to the enclosure as listed in Schedule 1. Inclusion of any of the components that are assessed together with the equipment as listed in Schedule. Addition of a rectangular trunking piece to an end wall of an enclosure may be fitted as per detail in Schedule Provision of electrical and/or mechanical interlocks to doors. Use of nonmetallic components as detailed in Schedule 3. Arrangement of entries to the enclosures in accordance with Schedule 4. Equipment construction and use restrictions in accordance with Schedule 5. Design criteria for enclosure series, and options therein, as detailed in drawings AFE001. Typical electrical circuit diagram is detailed in drawing AFE100, and may vary to suit site/client requirements. Fitting of an Oring gasket on each door, attachment or cover of an enclosure for ingress protection IP66. Provision of vertical panels or horizontal trays for the mounting of internal components, or in the case of large components fitted directly to bottom plate. Provision of threaded blind holes for the attachment of auxiliary items, as shown in drawing AFE 003. Provision of plain blind holes on the outside surfaces for fitment of drive screws, as shown in drawing AFE003. Page 1 of 1

for Certificate No.: IECEx TSA 09.004X Issue No.: 1 Schedule 1. Types of separately IECEx certified components (certified components) that may be incorporated into the AFE00 Series enclosures. Component type Certificate number or certification Push / rotary / switchgear operator AFC001 Receptacle / adaptor blanking plate AFC060 Conversion assemblies AFC070. See Note 1. Plugs and reducers AFC040 Compression type cable glands Multi conductor socket / bushing for IS circuits. Typically fitted to an exterior wall of an enclosure. Cable coupling devices such as receptacles and coupler adaptors. See Note. IECEx TSA 07.0037U Interface as included in this report Plain cylindrical or threaded aperture in enclosure IECEx TSA 07.0043U Bolted flange joint with optional threaded aperture IECEx TSA 07.0043U IECEx TSA 07.004 or other equipment certified component having identical threaded joint to AFC040 IECEx equipment certified to IEC 600790 / 600791 IECEx PTB 06.0093U or other equipment certified component having identical threaded joint to AFC040 IECEx TSA 09.0005U or other equipment certified component having identical flanged joint to AFC040 Bolted flange joint Threaded joint Threaded joint A type of bushing. Compound filled body with threaded joint attachment identical to AFC040 Bolted flange joint to blanking plate AFC060 dimensions Note 1. Conversion assemblies refers to a component that adapts varying sizes of flange mountings and essentially consists of two flange plates joined by a short tube section that may be filled with sealing compound. Conversion assemblies are used for mounting configurations. Note. The cable coupling device, typically a receptacle or adaptor, must have a flange interface (mounting pad detail) that provides the same attachment and flamepath provision as the range of blanking plates AFC060. The bushing of any such receptacle or adaptor that completes the enclosure must comply with the requirements of IEC 600790 and IEC 600791 for nonmetallic materials. Items used for test and assessment were coupler devices covered by TestSafe report 8684 applied here according to Ex TAG DS 004/006. National differences for Australia would include the use of receptacles and adaptors complying with the Australian Standards 199 and 1300, but only where these are also IECEx certified as complying with IEC 600790 and IEC 600791. Schedule. Assessment of components, not separately certified, is based on review of test results and assessments contained in TestSafe report 8707. Page of 1

for Certificate No.: IECEx TSA 09.004X Issue No.: 1 Component type Drawing reference Interface Polycarbonate window(s) AFC050 Cemented to machined area around opening and clamped by bolted frame. Trunking plate. Plain (blanking) or machined for up to 4 power bushings or receptacle / adaptor mountings and up to 6 (M3 max) threaded entries) AFC090 (Bushing) AFE005 (Trunking flange) AFE004 (cable Coupling devices) Bolted flange joint. See Note 1. Trunking, various sizes AFE005 Welded or bolted flanged joint. See Note. Power / insulator terminal bushing(s). See Note 3. AFC090 Cemented flange joint. Note 1. When used to mount high power bushings this plate would be welded or bolted to a transformer enclosure having a type of protection Ex p. The component is included in this report to assess the effectiveness of the flamepath on the Ex d enclosure side of the plate and the cemented joint of the bushing attachment. Note. This trunking has a machined flange which is for a bolted connection to a flange plate of a separate enclosure or for attachment of a plate that has provision for restrained receptacles, adaptors, high current bushings or threaded entries. Note 3. Power (terminal) bushings are high current bulkhead electrical feed through devices with solid epoxy, glass or ceramic insulation and with stud or bolted conductor connection. The generic type for this application has a 4fastener flange forming a cemented joint with a plate or enclosure wall. This test report relates only to the enclosure interface joint of the bushing and not to a specific type of bushing, which is outside the scope of this report. Schedule 3. Nonmetallic parts (introduced by use of components, etc). Component Drawing reference Nonmetallic part Polycarbonate window(s) AFC050 Lexan MR10 polycarbonate material and Silastic RTV 1080 cement Cable terminating device; Receptacle or coupler adaptor Multi contact socket with threaded attachment Power terminal bushing (Solid epoxy, glass or ceramic bushing with stud or bolted conductor) Conductor bushing with threaded attachment AFE001 Phase and pilot conductor pin bushing / insulation AFE001 A3 T9 N/A (IECEx equipment certified to IEC 600790 / 600791) Insulation (bushing) compound of sockets Solid epoxy, glass or ceramic insulator Solid epoxy bushing with through conductors (typical) Page 3 of 1

for Certificate No.: IECEx TSA 09.004X Issue No.: 1 Schedule 4. Type and number of apertures for components walls / door panel. (Refer to next page) Note 1. Note. Note 3. Note 4. Note 5. Note 6. Note 7. A greater number of windows may be provided if the total area of metal removed is the same or less than the area shown in parentheses. Maximum number of entries (without windows) of M5 or M3 (threaded joint) or 17 mm or 0 mm nominal (plain joint), for attachment of operators. When windows are fitted, the number of entries is reduced by the number of entries as per Table of drawing AFE00_1 for the specific window type. For threaded entries, the total permitted is based on them all being M63. A greater number of entries may be provided if the total area of all threaded entries in a wall or panel is equal to or less than the area of the maximum permitted M63 threaded entries. For plain entries, the total is based on them all being 90 mm diameter. A greater number of entries may be provided if the total area of all plain entries in a wall or panel is equal to or less than the area of the maximum permitted 90 mm plain entries. Where there are mixed types of entries in a particular panel, the total area of metal removed from that panel must not exceed the limit shown (mm ) in parentheses for that fitment. Provision of a welded or bolted trunking to a flange plate of a separate enclosure or for attachment of a plate that has provision for restrained receptacles, adaptors, high current bushings or threaded entries (refer drawings AFE005 and AFC090). Two threaded entries as per Note 3 may be provided with a trunking facility on the same wall. Refer to note 7 of drawing AFE00_1 Page 4 of 1

for Certificate No.: IECEx TSA 09.004X Issue No.: 1 Enclosure AFE00 Series Type and Number of Aperture for components Fitment Windows in front Door Panel / Panel Up to 00 mm x 80 mm (16,000 mm ) Up to 50 mm x 180 mm (45,000 mm ) Up to 330 mm x 00 mm (66,000 mm ) Threaded or plain entries in door panel / panel without window, as above. Note 1 & Window openings in front flange up to 00 mm x 80 mm Comp A 01 0 03 & 07 Enclosures Type 04 & 05 30 40 90 06 Comp A Front Rear Front Rear 1 1 1 1 1 1 1 1 1 7 49 104 5 55 55 104 30 49 8 5 10 (3,000 mm ) (3,000 mm ) 1 (16,000 mm ) Page 5 of 1

for Certificate No.: IECEx TSA 09.004X Issue No.: 1 Fitment Windows in front Door Panel / Panel Threaded or plain entries in front flange. Note 1 Threaded entries in end or common walls. Note 3 & 5 Flange mounted components to end walls (Cable coupling devices, blanking plates). Note 4 & 5 Trunking (end Panel). Note 6 & 7 Comp A 01 0 03 & 07 Enclosures Type 04 & 05 30 40 90 06 Comp A Front Rear Front Rear 6 10 1 6 4 3 (1,000 mm ) 1 (1,000 mm ) 30 mm ) 14 mm ) 3 mm ) mm ) 3 mm ) mm ) 3 mm ) mm ) 30 mm ) 14 mm ) 13 (41,000 mm ) 6 (41,000 mm ) 9 (30,300 mm ) 4 (30,300 mm ) 3 mm ) mm ) 1 1 1 1 1 1 1 7 (4,300 mm ) 3 (4,300 mm ) Note: For detailed information on the above Table refer to Notes 1 to 7 in Schedule 4. Page 6 of 1

for Certificate No.: IECEx TSA 09.004X Issue No.: 1 Equipment construction and use restrictions. Schedule 5. Documentation supplied with each AFE00 Series enclosure or assembly of enclosures shall: o Identify the position, size and type of each cable entry. Where these are threaded entries, the type of thread is to be specified. o Provide an instruction manual, customised to the specific application. Ex certified components shall be installed in accordance with their respective conditions/limitations of certification. Internal components are to be assembled so as to provide adequate space between components, and between components and sidewalls, to reduce the possibility of hot spots. The selection and positioning within the enclosure of heat dissipating components shall prevent the temperature of the enclosure, or parts of the enclosure, exceeding the maximum service temperature of any surface or other component that completes the enclosure. In general: o o o o 150 ºC for the external surfaces of the enclosure generally; 75 ºC for the mounting point of any restrained receptacle or adaptor; 75 ºC for the mounting point of any cable gland; and 75 ºC for the mounting surround of any polycarbonate window or the lens itself. The selection, rating and positioning within the enclosure of heat dissipating components shall prevent the rated ambient conditions of Ex equipment (eg Ex barrier, Ex associated equipment, etc.) being exceeded. The enclosures shall not contain a general battery derived supply. Installed equipment may include cells or batteries but only those certified as Intrinsically Safe and suitable for use in this kind of enclosure and not intended to be charged in the Ex d enclosure. Use of these batteries is limited for memory back up only. Internal equipment and mounting plates shall be arranged in such a manner that at least 0% of each plane crosssection area is free to permit unimpeded gas flow, to preclude pressure piling. This area may be a summation of areas with a minimum dimension of 1.5 mm in any direction. Where fitted, bushing type sockets shall have a threaded connection equivalent to the stopping plugs covered by certificate IECEx TSA 07.004U and shall contain only circuits that comply with IEC 60079. External, nonwelded, joints of enclosure parts that are potentially in parallel, or form part of earth circuits, (such as adaptor or receptacle flanges) must be crossbonded. Each enclosure shall be subjected to a routine overpressure test, with a minimum test pressure as shown in below table and duration of application of overpressure minimum of 10 seconds and not exceeding 60 seconds. The enclosure may be tested empty, but must include all fitted components that are not themselves exempt from routine testing. Page 7 of 1

for Certificate No.: IECEx TSA 09.004X Issue No.: 1 Enclosure type Minimum test pressure (kpa) 01A* 1075 kpa 01B** 1075 kpa 0 1075 kpa 03 1075 kpa 04 1075 kpa 05 1075 kpa 06 1075 kpa 07 1075 kpa 30A* 30B** 1075 kpa 1075 kpa 40 1075 kpa 90 40 kpa Note: * Denotes Auxiliary Chamber and ** denotes Main Chamber Drawings pertaining to Issue 0 of this Certificate: Drawing / Document No.: Page/s: Title: Revision Level: Date: (yyyymmdd) AFE00_1 1 Ampcontrol Series AFE00 Flameproof Enclosures Fitting and Machining Details AFE00_ 1 Ampcontrol Series AFE00 Flameproof Enclosures Fitting and Machining Details AFE00_3 1 Ampcontrol Series AFE00 Flameproof Enclosures Fitting and Machining Details AFE00_4 1 Ampcontrol Series AFE00 Flameproof Enclosures Fitting and Machining Details G 010036 C 00919 A 0094 0 010036 AFE001 1 Design Brief for Flameproof Enclosures 14 01003 AFE00 1 Flameproof Enclosure Door / Flange Flamepath Details 7 010040 AFE003 1 Flameproof Enclosure Drilling Detail 9 01003 AFE004 1 Flameproof Enclosure Cable Coupling Devices Mounting Details 6 009103 AFE005 1 Flameproof Enclosure Transformer Trunking Flange 4 009103 Page 8 of 1

for Certificate No.: IECEx TSA 09.004X Issue No.: 1 Drawing / Document No.: Page/s: Title: AFE100 1 AFE000 series Control, Monitoring and Distribution Typical components & Single Line Revision Level: Date: (yyyymmdd) 0 008105 AFC014 1 Interlocking Arrangement Options 3 01003 AFC050 1 Flameproof Windows F 01003 AFC080 1 Typical FLP Tags & Identification Label H 009103 AFC090 1 AFE100 Series transformer bushing/ plate 5 009103 Conditions of Certification pertaining to Issue 0 of this Certificate: 1. It is special condition of safe use that, the precautions necessary to avoid the risk from electrostatic discharge from any polycarbonate window fitted to an enclosure shall be applied in accordance with the manufacturer s instructions for the equipment. It is specific condition of safe use that, for any IECEx certified Ex component fitted to the enclosure, the original manufacturer of the Ex component shall be contacted for information relating to the dimensions of flameproof joints. Variations pertaining to Issue 1 of this Certificate: Schedule of Variations 1. Option to weld ATF Series 170 enclosure to the external wall or door of the AFExxx Series enclosures.. Option to include mounting bosses through wall of enclosure. 3. Maximum aperture dimensions for cable coupling devices aligned with AS/NZS 199:009 and AS/NZS 1300:009. 4. Increased number of threaded entries that may be provided with a trunking facility. 5. Increased number of threaded or plain entries in door panel without windows (0, 03, 07, 04, 06, 40, 90 enclosures). 6. Increased number of threaded or plain entries in front flange (03 enclosure). 7. Addition of new enclosure AFE08. 8. Addition of new manufacturing location of Ampcontrol UK Ltd. 9. Minor editioral changes to some drawings. Schedule 6. Type and number of apertures for components walls / door panel. (Refer to next page) Page 9 of 1

for Certificate No.: IECEx TSA 09.004X Issue No.: 1 Enclosure AFE00 Series Type and Number of Aperture for components Fitment Windows in front Door Panel / Panel Up to 00 mm x 80 mm (16,000 mm ) Up to 50 mm x 180 mm (45,000 mm ) Up to 330 mm x 00 mm (66,000 mm ) Threaded or plain entries in door / panel without window, as above. Note 1 & Window openings in front flange up to 00 mm x 80 mm Threaded or plain entries in front flange. Note 1 Threaded entries in end or common walls. Note 3 & 5 Flange mounted components to end walls (Cable coupling devices, blanking plates). Note 4 & 5 Trunking (end Panel). Note 6 & 7 Comp A Note: For detailed information on the above Table refer to Notes 1 to 7 in Schedule 4. Enclosure Type 01 0 03 07 04 05 06 08 30 03 40 90 Front Rear Front Rear 1 1 1 1 1 1 1 7 49 104 64 64 64 64 104 64 64 30 49 8 64 15 (3,000 mm ) (3,000 mm ) (3,000 mm ) (3,000 mm ) (3,000 mm ) (3,000 mm ) 1 (16,000 mm ) 6 10 16 1 6 6 6 4 3 (1,000 mm ) 1 (1,000 mm ) 30 mm ) 14 mm ) 3 mm ) mm ) 3 mm ) mm ) 3 mm ) mm ) 3 mm ) mm ) 30 mm ) 14 mm ) 3 mm ) mm ) 3 mm ) mm ) 13 (41,000 mm ) 6 (41,000 mm ) 9 (30,300 mm ) 4 (30,300 mm ) 3 mm ) mm ) 1 1 1 1 1 1 1 1 1 1 7 (4,300 mm ) 3 (4,300 mm ) Page 10 of 1

for Certificate No.: IECEx TSA 09.004X Issue No.: 1 Schedule 7. For equipment construction and use restrictions Schedule 5 applies, except as varied in the following table. Enclosure type AFE Enclosure empty volume (L) Minimum test pressure (kpa) 01A* 100 1075 01B** 850 1075 0 950 1075 03 1080 1075 04 140 1075 05 950 1075 06 140 1075 07 1080 1075 08 670 85 30A* 90 1075 30B** 10 1075 40 540 1075 90 90 40 Note: * Denotes Auxiliary Chamber and ** denotes Main Chamber Drawings pertaining to Issue 1 of this Certificate: Drawing/Document No.: Page/s: Title: Revision Level: Date: (yyyymmdd) AFC080 1 Typical FLP Tags and Identification Label I 01075 AFE001 1 Design Brief for Flameproof Enclosures (Referred to as General Notes) 15 00317 AFE003 1 Flameproof Enclosure Drilling Detail 0049 AFE004 1 Flameproof Enclosure Cable Coupling Devices Mounting Details AFE006 1 ATF170 Enclosure Welded to AFExxx Series Enclosure AFE00_1 1 Ampcontrol Series AFE00 Flameproof Enclosures Fitting & Machining Details AFE00_4 1 Ampcontrol Series AFE00 Flameproof Enclosure Fitting & Machining Details 7 00308 1 0049 I 010719 A 01017 Page of 1

for Certificate No.: IECEx TSA 09.004X Issue No.: 1 Conditions of Certification pertaining to Issue 1 of this Certificate: All previous conditions still apply. Page 1 of 1