Occasional very high DBG were rated HBG+ grading, when bubble signals reached grade 3,5 in the adapted Spencer scale described below.

Similar documents
A. Marroni , R. Cali Corleo , C. Balestra , P. Longobardi 4-6, E. Voellm 5-6, M. Pieri 1-6, R. Pepoli 6-7

Effect of varying deep stop times and shallow stop times on precordial bubbles after dives to 25 msw (82 fsw).

min 3 S min 3 S min 6 3 S min S min

DECOMPRESSION PROFILES WITH DEEP STOPS: COMPARATIVE DOPPLER STUDY WITH THE PROCEDURES OF THE FRENCH NAVY.

6 th ECHM CONSENSUS CONFERENCE on Prevention of dysbaric injuries in diving and hyperbaric work

Patent Foramen Ovale and Fitness

NOBENDEM. Advanced Decompression Tables

Ascent to Altitude After Diving

Computers and Dive Tables. Revised September 17, 2017

suunto_halfa4_viewing 16/6/2003 8:14 AM Page 1 Suunto Reduced Gradient Bubble Model

Ratio Deco. Overview. Global Perspective

Decompression Sickness

The Use of Venous Gas Emboli to Validate Dive Computers

UNDERSTANDING A DIVE COMPUTER. by S. Angelini, Ph.D. Mares S.p.A.

MATHEMATICAL EVALUATION OF MULTI-LEVEL DIVING

Fundamentals of Decompression

Abstracts JUNE 24-25, Copyright 2009 Undersea and Hyperbaric Medical Society, Inc.

DECOMPRESSION THEORY - NEO-HALDANE MODELS

23th Capita Selecta Duikgeneeskunde. Amsterdam, 03/17/2018: 21 st. Century Decompression Theory

Defense Technical Information Center Compilation Part Notice

Contents. Introduction...1

Technical Diving Software for. User Manual

DECOMPRESSION PHYSIOLOGY and SUSCEPTIBILITY

SCUBA - self contained underwater breathing apparatus. 5 million sport scuba divers in U.S. 250, ,000 new certifications annually in U.S.

Diving at Altitude. Part One: Starting with Residual Nitrogen. By John Adsit January 30, 2018

The Pisa Inter-University Initiative for the medical and physiological support of complex and deeper diving

Recent advances in diving medicine research. DAN Europe VGE Studies

Instruction Guide for using Dive Tables (draft)

Decompression Planning for TMX Dives between m

An Overview of Decompression

Decompression Sickness in Extravehicular Activities

Addendum 2: Correlations of VPM-B(2), RGBM, and GF Gradients and Tensions

SWISS UNDERWATER HYPERBARIC MEDICAL SOCIETY

Pulmonary (cont.) and Decompression

Introduction. U.S. Navy Diving Manual (Mar-1970)

Detection of venous gas emboli after repetitive breath-hold dives: case report

DIY DECOMPRESSION. By Stuart Morrison. (c) 2000 Stuart Morrison/Liquid Technology

Instructions For Use. Recreational Dive Planner DISTRIBUTED BY PADI AMERICAS, INC.

12m. Instructions For Use. 14m. 16m. 18m. Recreational Dive Planner. 20m DISTRIBUTED BY PADI AMERICAS, INC.

. Vann, Ph.D. P.B. Bennett, Ph.D., D.Sz. ,frice o, Naval Research Contract N C-01.O; February 13, S",i., i " ;, c,,a ppzoved

FLYING AFTER RECREATIONAL DIVING Workshop Proceedings

CHAPTER 9 $LU'HFRPSUHVVLRQ

Defense Technical Information Center Compilation Part Notice

Decompression Practice Robert W Hamilton and Ed Thalmann

Validation of Dive Computer Algorithms

Atmospheres and Decompression

Counterdiffusion Diving: Using Isobaric Mix Switching To Reduce Decompression Time

1/21/2014. Diving Physics. Introduction

Aerospace Physiology. Lecture #11 Oct. 7, 2014 Cardiopulmonary physiology. Musculoskeletal Vestibular Neurological Environmental Effects MARYLAND

Planning Decompression Diving Gas Requirements in Open Water

Guidelines for. Diabetes. & Recreational Diving

Diabetes and Recreational Diving

Spring 1999 Hyperbaric Medicine Newsletter. Fellows Presentations. Saturation Diving

ENT & diving pathology: IE Decompression Sickness vs IE Barotrauma

Techniques for Deeper Diving

Curriculum Vitae. J. Morgan Wells

Decompression Illness in CA workers

THE NOBENDEM AIR/NITROX DECOMPRESSION PROFILE CALCULATOR. Copyright 1998

"GOING DIVING" BSAC Diving Officers' Conference Saturday 4th December 2004 New thoughts on decompression JP Imbert - Divetech, France

Diving Medicine USN Diver/SEAL Submarine Overview / Tom Kersch, CAPT, MC!!

U.S. Navy Dive Computer Validation

SCUBA DIVING ASSISTANT Version: :21.00

NAVAL SUBMARINE MEDICAL RESEARCH LABORATORY

Per-capita claims rates for decompression sickness among insured Divers Alert Network members

SECOND EUROPEAN CONSENSUS CONFERENCE ON HYPERBARIC MEDICINE THE TREATMENT OF DECOMPRESSION ACCIDENTS IN RECREATIONAL DIVING

Aladin ONE (Matrix) User Manual

Note: You will receive no credit for late submissions. To learn more, read your instructor's Grading Policy. A Law for Scuba Divers

Aerospace Physiology MARYLAND. Cardiopulmonary Physiology. Musculoskeletal Vestibular Neurological. Respiratory Cardiovascular U N I V E R S I T Y O F

Chapter 5 Decompression, Dive Tables, and Dive Computers

Defense Technical Information Center Compilation Part Notice

Deutsch. Operating Manual. English. Français. Smart PRO Smart COM SWISS MADE BY UWATEC AG

CHOCOLATE, SEX AND SCUBA DIVING WHY THEY RE GOOD FOR YOU AND HOW TO DO THEM SAFELY...

OPTIMIZATION OF DIVING WITH NITROX OVER-OXYGENATED BREATHING MIXTURES, TO DEPTHS OF METRES Mircea DEGERATU*, Simona RUS**, Ana ION***

Parameter estimation in decompression sickness Problem presented by Geoff Loveman Submarine Escape and Diving Systems QinetiQ, Haslar, Gosport

Evaluating the Effects of Stressors on Immune Function during Simulated Dives in Marine Mammals

RECOMPRESSION TREATMENT FOR DECOMPRESSION ILLNESS: 5-YEAR REPORT ( ) FROM NATIONAL CENTRE FOR HYPERBARIC MEDICINE IN POLAND

DCI Demystified By Eric Hexdall, RN, CHRN Duke Dive Medicine

Divers Alert Network 2007 Internship Final Report

DATAMASK HUD. Water or Push Button Modified Haldanean / DSAT (Diving Science and Technology) Database Each Level provides No.

Deco Planner Manual. This document is written to support version November Copyright GUE INC

EVALUATION OF DIVE COMPUTER OPTIONS FOR POTENTIAL USE IN 300 FSW HELIOX/TRIMIX SURFACE SUPPLIED SCIENTIFIC DIVING

Reverse dive profiles: the making of a myth

Norwegian Diving- and Treatment Tables

NEMO EXCEL User s Guide

Seminar Descriptions (Room #S230E)

4/18/2012. Northern Fur Seal Three Foraging Patterns. Thermocline. Diving Physiology and Behavior

CHROMIS DIVING COMPUTER - DESIGNED BY DIVING ENGINEERS WARNING

ELEDT S APR24 19 DECOMPRESSION SICKNESS AFFECTING THE TEMPOROMANDIBULAR JOINT. Author:

Operating Manual. Smart Z. English Deutsch. Français SWISS MADE BY UWATEC AG

Nitrogen and Cognitive Impairment

University System of Maryland (USM) Dive Plan Approval Form To be submitted to the USM Scientific Diving Safety Officer

GUIDELINES FOR THE DIVER ** EXAMINATION

Aladin SPORT User manual

b. Provide consultation service to physicians referring patients. c. Participate in weekly wound care clinic and biweekly diving medicine clinic.

Homeostasis and Negative Feedback Concepts and Breathing Experiments 1

Risk Factors for Decompression Illness

A VALID APPROACH TO CORRECT CAPILLARY PRESSURE CURVES- A CASE STUDY OF BEREA AND TIGHT GAS SANDS

The Varying Permeability Model. By Dan Reinders (with additional graphics and animations by Richard Pyle)

Decompression sickness (DCS) after sea diving, aviation,

Procedure 1: Volume vs. Pressure 1.) Using the lap tops, go to the Physics Education Technology from the University of Colorado at:

Transcription:

What Ascent Profile for the prevention of Decompression Sickness? II - A field model comparing Hill and Haldane Ascent modalities, with an eye to the development of a bubble-safe decompression algorithm. DAN Europe DSL Special Project 01-2002 Haldane vs Hill Speed of Ascent Study. Alessandro Marroni 1,2, Peter B. Bennett 4,5, Costantino Balestra 1,3, Ramiro Cali-Corleo 1,2, Peter Germonpre 1,6, Massimo Pieri 1, Corrado Bonuccelli 1 DAN Europe Foundation, Research Division. 2) Division of Baromedicine, University of Malta Medical School. 3) Haute Ecole Paul Henry Spaak, Human Biology Dept. Bruxelles, Belgium. 4) Divers Alert Network (DAN) America. 5) Duke University Medical Center, Durham, NC, USA. 6) Center for Hyperbaric Oxygen Therapy, Military Hospital Bruxelles Introduction Circulating venous gas bubbles have been found to be a common occurrence in the otherwise uneventful recreational dives monitored during the DAN Europe s Project SAFE DIVE. Doppler monitored bubbles have been detected in 37,4 of all the monitored dives. 25,4 of the dives produced Low Bubble Grade recordings only, while 12 produced High Bubble Grades and 2,4 produced Very High Bubble Grades, between grade 3 and 4 according to the Spencer scale. Repetitive dives showed a different incidence of post dive VGE, with only 15 of the repetitive dives bubble free and HBG and LBG recorded in 67 and 18 of the repetitive dives, respectively. The DAN Europe SAFE DIVE project showed that post dive High Bubble Grades are directly related to Fast to Medium Half Time Tissues, and Nitrogen Venous Partial Pressure greater than 80 of the allowed M Value for that tissue. The modification of the ZH-L8 ADT algorithm by the introduction of a Proportional M-Value Reduction Concept (PMRC) to the fast and medium HT Tissue compartments, without altering the original speed of ascent to and between any planned stop resulted in a modified ascent slope and in the introduction of extra deep stops during the ascent. This eliminated the occurrence of significant post-dive Doppler detectable Venous Gas Emboli. The results also showed no apparent relation between instant speed (the actual speed of ascent calculated from the depth/time profile of the UWATEC computer) and post-dive Doppler bubble detection. Contradictory results were observed during several test chamber dives with instant speeds of up to 25 meters per minute and no bubble signal detection, versus significant high bubble grade signals after dives made according to the standard ZH-L8 ADT algorithm, with instant speeds of ascent never faster than 10 meters per minute. These observations suggest that the Delta-P imposed on the leading tissue, irrespective of the instant speed of ascent in any given tract of the ascent slope, is the critical factor for precordially detectable bubble production. This fits with a Haldanian approach to decompression computation. Haldane theorized that divers could ascend quickly to a depth that was half the absolute pressure of their deepest descent. He then plotted a slow return to the surface with stops to eliminate the excess nitrogen. Leonard Hill by contrast believed in a linear ascent theory. However, Haldane showed that this was ineffective and still left the nitrogen tension too high on surfacing resulting in DCS the deep stop was needed. Yet in his published tables he did not use a deep stop (8). A special field study was started, in cooperation with DAN America, to test this hypothesis. Materials and Methods The study was done with a group of 15 volunteer divers who, after having read and signed an informed consent form, accepted to dive on 8 different weekends, each one of 8 possible combinations of ascent rate and decompression stops of the same dive to 25 m for 25 min, followed by a repetitive dive to 25 m for 20 min after a 3 hours and 30 minutes surface interval. The ascent rates being of 18, 10 and 3 m/min, with or without 5 min stops at 15 and 6 meters. The 18 m/min ascent profile without any stop was intentionally not tested for safety reasons.

At the time this paper is being prepared 7 out of 8 profiles have been dived, 6 of which by the majority of the volunteer divers and profile number 7 by 3 volunteer divers, while profile number 8 is still being completed. Two volunteer divers dropped out of the study before completing the fifth profile, due to pregnancy. Some divers did not, occasionally dive the repetitive dive profile due to feeling too cold or excessively adverse sea conditions. In total, up to now, we analyzed 24 dives for profile 1-1R, 25 dives for profile 2-2R, 27 dives for profile 3-3R, 21 dives for profile 4-4R, 19 dives for profile 5-5R, 17 dives for profile 6-6R, and 6 dives for profile 7-7R, for a total of 139 man-dives and 834 Doppler Readings. The divers served as their own control for precordially detected Doppler Bubbles and possible symptoms of DCS. TABLE I - Matrix of the experimental Dive Profiles Profile Depth Time Ascent Speed m/min Stop 15 m Stop 6 m Total Ascent Time minutes 1 25 25 10 0 0 2,5 1R 25 20 10 0 0 2,5 2 25 25 3 0 0 8 2R 25 20 3 0 0 8 3 25 25 18 0 5 6,5 3R 25 20 18 0 5 6,5 4 25 25 10 0 5 7,5 4R 25 20 10 0 5 7,5 5 25 25 3 0 5 13 5R 25 20 3 0 5 13 6 25 25 10 5 5 12,5 6R 25 20 10 5 5 12,5 7 25 25 18 5 5 11,5 7R 25 20 18 5 5 11,5 8 25 25 3 5 5 18 8R 25 20 3 5 5 18 All dives were recorded for time/depth profile by DAN Europe Black Boxes modified UWATEC computers as described in our previous work (1,2) which were worn by the divers to assure objective dive profile recording and the availability of data ready for mathematical analysis of the computed tissue saturation. Doppler Recordings were performed by specially trained members of the volunteer divers group, using an Oxford Instruments 3,5 MHz probe with an in-house assembled digital recorder, trained according the methods developed by our group and qualified as Research Technicians (1,2). The recordings were made over 1 minute and every 15 minutes up to 90 minutes after the dives, and subsequently evaluated in undisturbed laboratory conditions by a blinded evaluator. The Doppler Bubble Signals were scored according to the Spencer Scale (3) and also according to a Doppler Bubble Grading System that we designed, as a variant of the Spencer method, as follows (4-6):? LBG Low Bubble Grade: occasional bubble signals, Doppler Bubble Grades (DBG) lower than 2 in the Spencer Scale? HBG High Bubble Grade: Frequent to continuous bubble signals, DBG 2 and higher in the Spencer scale. Occasional very high DBG were rated HBG+ grading, when bubble signals reached grade 3,5 in the adapted Spencer scale described below.

A further adaptation to the Spencer Scale was made, introducing half grades to allow for a more linear grading, as follows (Expanded Spencer Scale ESS):? Grade 0 = No Bubble Signals? Grade 0,5 = 1-2 sporadic Bubble signals over the 1 minute recording? Grade 1 = up to 5 Bubble signals over the 1 minute recording? Grade 1,5 = up to 15 Bubble signals over the 1 minute recording, with bubble showers? Grade 2 = up to 30 Bubble signals over the 1 minute recording? Grade 2,5 = more than 30 Bubble signals over the 1 minute recording, with bubble showers? Grade 3 = virtually continuous Bubble signals over the 1 minute recording? Grade 3,5 = continuous Bubble signals over the 1 minute recording, with numerous bubble showers? Grade 4 = continuous Bubble signals over the 1 minute recording, with continuous bubble showers A Bubble Score Index - BSI was obtained for each dive and for the combined Dive plus Repetitive Dive for each experimental profile as follows: all the ESS gradings obtained from the all the Doppler Readings were summed up and divided by the number of volunteer divers participating in each experimental dive profile. The resulting BSI was considered an index of the decompression stress imposed on the divers by that specific profile. All the dive profile data, downloaded from the DAN Europe Black Boxes were mathematically analyzed and plotted against the maximum allowed M valued for each of the 8 tissue compartments of the Bühlmann ZHL8- ADT algorithm, to allow for comparison between the Doppler BSI and the computed tissue saturation, expressed as a percentage of the M Value, during the different phases of the ascent and at reaching the surface. A total of 139 man-dives and 834 Doppler readings were made and analyzed. Results The results from the group of 15 volunteer divers who dived 7 of the 8 profiles show that the highest Doppler scores are observed after the no stop ascents (pure Hill approach) with a 5 and 10 min HT tissue saturation exceeding 60 and 80 of the allowed M Values. For these dives the BSI reached values of 8,79 for the speed of ascent of 3 m/min and of 7,34 for the speed of ascent of 10 m/min. Medium-high Doppler scores were observed after the dives with a stop at 6 m for 5 minutes (the current hybrid Hill-Haldane approach), with a 5 and 10 min HT tissue saturation exceeding 30 and 65 respectively and BSI of 8,53 for the 3m/min speed of ascent, 7,38 for the 18 m/min speed of ascent, and 5,50 for the 10 m/min speed of ascent. When the deep stop was introduced (pure Haldanian approach), the 5 and 10 minutes tissue tensions dropped to 25 and 50 respectively and the observed BSI (Doppler bubble score index) reached their minimum, with BSI of 3,25 for the 18m/min speed of ascent and 2,03 for the 10-m/min speed of ascent. Table II Fast Tissue Saturation and Bubble Scores after the different experimental dive Profiles Ascent Rate Stops 5 min Tissue Saturation (0 100 ) 10 min Tissue Saturation (0 100 ) Bubble Score BSI Total Time to Surface minutes 3 m/min (Profile 2) No Stop 48 75 8.79 8 3 m/min (Profile 5) 6 m / 5 min 30 60 8.53 13 3 m/min (Profile 8) 15 + 6 m / 5 min To be done To be done To be done 18 10 m/min (Profile 1) No Stop 61 82 7.34 2.5 10 m/min (Profile 4) 6 m / 5 min 43 65 5.50 7.5 10m/min (Profile 6) 15 + 6 m / 5 min 25 52 2.03 12.5 18 m/min (Profile =) No Stop Not tested Not tested Not tested Not tested 18 m/min (Profile 3) 6 m / 5 min 42 60 7.38 6.5 18 m/min (Profile 7) 15 + 6 m / 5 min Not available yet at Not available yet at time of submission time of submission 3.25 11.5 Note: The 3 m/min speed of ascent (experimental profile 8) has not been dived yet. The mathematical analysis of the tissue saturation for profile 6 is not yet completed at the time of the submission of this paper and will be presented

Not only the variation of the speed of ascent and the introduction of the deep stop at 15 meters favorably affected the general Bubble Score Index after these experimental open water dives, but also the distribution of Doppler Bubble readings and the relative incidence of Zero, Low Grade, High Grade and High Grade Plus readings among the divers and over time was positively influenced, as shown in Table II. TABLE III Incidence of Doppler Detected Bubbles after the different experimental dive Profiles Dive Profile BSI Grade 0 Low Grade High Grade Very High Grade 1 1R 7.34 9.7 63.9 17.4 9.0 2 2R (worst) 8,79 10.0 50.6 19.4 20.0 3 3R 7.38 16.0 56.2 19.8 8.0 4 4R 5.50 16.7 67.4 11.2 4.7 5 5R 8.53 5.3 63.2 21.9 9.6 6 6R (best) 2.03 60.8 37.2 2.0 0.0 7 7R (next to best) 3.25 41.7 55.6 2.7 0.0 The best results, both expressed as total Bubble Score Index, and as shown by the relative incidence of zero, Low Grade and High Grade Precordial Doppler bubble readings, were obtained when the extra deep stop at 15 meters was introduced (profiles 6 and 7 - pure Haldane), while the worst results were obtained for the linear direct ascent to the surface with a speed of 3 meters per minute (profile 2 - pure Hill). Conclusions The fact that the majority (65) of Decompression Sickness cases within the Recreational Diving Community are neurological in nature and that the spinal cord should be considered a fast compartment, with a half-time of 12,5 minutes, made us think and believe that the answer to the dilemma of the frequent unexplainable neurological decompression sickness cases is to be found, among other possible factors, in the improvement of the ascent profile, with a special attention to the short half-time compartments the Fast Tissues. This lead to the series of studies started with DAN s project Dive Safety and Safe Dive and continuing now, in America and Europe, with Project Dive Exploration, the Diving Safety Laboratory and their related Special Projects, such as this Speed of Ascent Study The results of the current study, although still limited to 7 of the 8 experimental dive profiles, show that the addition of an extra deep stop, in addition to the currently recommended safety stop, to the ascent profile from normal No-Decompression recreational compressed air dives, kept the computer-estimated PltN2 levels (Leading Tissue Nitrogen Levels) of the fast and medium HT compartments within the tissue supersaturation M- Values indicated as safe by our previous studies and according to our Proportional M-Value Reduction Concept (PMRC), and greatly reduced Precordial Doppler Detected Gas Bubbles. This is confirmed in this study of 15 volunteer divers exposed to 139 repetitions with a dive matrix to 25 meters for 25 minutes, followed by a repetitive dive to 25 meters for 20 minutes after a 210 minutes interval, and repeating the dive on 8 different weekend dives following 8 different ascent profiles, with speed of ascent of 3, 10 and 18 meters per minute, with or without 5 minute stops at 15 and/or 6 meters. The volunteer divers acted as their own control. These observations also confirm that the Delta-P imposed on the leading tissue, irrespective of the absolute speed at any time of the ascent ( instant speed ), is the critical factor for the production of precordially detectable bubbles, and, possibly, for the development of DCI in recreational dives. The results indicate that slow, linear ascents (Hill approach) may be significantly more bubble-productive than ascents with even more rapid rates to reach intermediate stops and a similar total time to de-gas. From our present data it would appear that the best combination to minimize post-dive bubble production is a speed of ascent of 10 meters per minute combined with Haldanian type stops, generally respecting to the 2:1 Haldanian decompression principle, which has, despite its good initial results, changed over time with the advent of decompression ratios as high as 4:1 for certain tissues, particularly for the fast half-time compartments. The study will continue with a revision of the currently accepted recreational diving practices, with regard to an optimal ascent modality, by the implementation of a new algorithm to respect and resemble the observed biological results.

References 1. Marroni A., Cali Corleo R. et Al. Project Safe Dive - a preliminary report. In: S.A. Sipinen, M. Leiniö (Eds), Proceedings of the XXI Annual Meeting of the EUBS; 1995:216-221. ISBN 952-90-6626-0 2. Marroni A, Cali-Corleo R, Denoble P. Understanding the safety of recreational diving. DAN Europe s Project SAFE DIVE Phase I: Fine tuning of the field research engine and methods Proceedings of the International Joint Meeting on Hyperbaric and Underwater Medicine, EUBS, ECHM, ICHM, DAN. Milano 4-8 September, 1996, p. 279-284 3. Spencer MP, Johanson DC. Investigation of new principles for human decompression schedules using the Doppler ultrasonic blood bubble detector. Tech. Report to ONR on contract N00014-73-C-0094, Institute for Environmental Medicine and Physiology, Seattle, Wash. USA. 1974 4. Marroni A., Cali Corleo R., Balestra C., Voellm E, Pieri M. Incidence of Asymptomatic Circulating Venous Gas Emboli in unrestricted, uneventful Recreational Diving. DAN Europe s Project SAFE DIVE first results. EUBS 2000 Proceedings. Diving and Hyperbaric Medicine, Proceedings of the XXVI Annual Scientific Meeting of the European Underwater and Baromedical Society, R. Cali Corleo Ed. Malta 14-17 September, 2000: 9-15 5. Marroni A, Cali Corleo R, Balestra C., Longobardi P., Voellm E., Pieri, M., Pepoli R. Effects of the variation of Ascent Speed and Profile on the production of Circulating Venous Gas Emboli and the Incidence of DCI in Compressed Air Diving. Phase 1. Introduction of extra deep stops in the ascent profile without changing the original ascent rates. DSL Special Project 01/2000. EUBS 2000 Proceedings. Diving and Hyperbaric Medicine, Proceedings of the XXVI Annual Scientific Meeting of the European Underwater and Baromedical Society, R. Cali Corleo Ed. Malta 14-17 September, 2000: 1-8 6. Marroni A, Cali Corleo R, Balestra C., Longobardi P., Voellm E., Pieri, M., Pepoli R. The use of a Proportional M-Value Reduction Concept (PMRC) Changing the Ascent Profile with the introduction of extra deep stops reduces the production of Circulating Venous Gas Emboli after Compressed Air Diving. DSL Special Project 01/2001. EUBS 2001 Proceedings of the 27 th Annual Meeting. U van Laak Ed. Hamburg 12-16 September, 2001: 69-73 7. Marroni A, Cali Corleo R, Balestra C., Longobardi P., Voellm E., Pieri, M., Pepoli R. The use of a Proportional M-Value Reduction Concept (PMRC) The Speed of Ascent Dilemma: Instant Speed of Ascent or Time to Surface which one really matters? Instant speed of ascent vs Delta-P in the leading tissue and post dive Doppler Bubble production.. DSL Special Project 02/2001. EUBS 2001 Proceedings of the 27 th Annual Meeting. U van Laak Ed. Hamburg 12-16 September, 2001: 74-78 8. Bennett PB, Marroni A, Balestra C, Cali-Corleo R, Germonpre P, Pieri M, Bonuccelli C. What ascent profile for the prevention of decompression sickness? I Recent Research on the Hill/Haldane ascent controversy. Paper presented at the 28 th Annual Meeting of the EUBS, Bruges, 5-8 September 2002. 9. Lanphier EH. A historical look at ascent. In Proceedings Biomechanics of Safe Ascent Workshop. Eds. M Lang & G Egstrom. American Academy of Underwater Sciences. Woods Hole, Massachusetts; 1989:5-8 10. Edmonds C, Lowry C and Pennefather J. Historical and physiological concepts of decompression. In Diving and Subaquatic Medicine, Butterworth-Heinemann; 1992: 40-158.