OPERATION & INSTALLATION INSTRUCTIONS

Similar documents
MODEL 9875 STADIUM BASEBALL SCOREBOARD. Instruction Manual

Miniature controls. Contactors. Overload relays. Starters. Control relays

T i m i n g S y s t e m s. RACEAMERICA, Inc. P.O. Box 3469 Santa Clara, CA (408)

Installation, operating and maintenance Instructions for Seemag bypass level indicator

OC Panel High Limit Aquastat Kit, Manual Reset p/n

BUBBLER CONTROL SYSTEM

GV Standard X-Vent. Setup, Commissioning & Installation Guide

BUBBLER CONTROL SYSTEM

Wireless Belt Pack BP Conductor Jack with Radio Transmit & Volume Control

Compact Pressure Switch

700 SERIES BMS II BUBBLER MONITORING SYSTEM

Wireless Belt Pack BP Conductor with Radio Transmit

Model 130M Pneumatic Controller

CDS-2000 CO 2 Sensor Verification, Calibration, and Troubleshooting Bulletin

Compact Pressure Switch

Watts. xppower.com. Input. General. Environmental. Output. EMC & Safety. Output Voltages from 2.5 V to 48 V. Non-standard Outputs Available

TECHNICAL INSTALLATION MANUAL FOR AUTOMATIC GATES

GasSense NDIR User Manual

JOLLY2. Installation user s manual. 6 different operating modes selectable. version 3.3. DATA TO BE FILLED OUT BY THE INSTALLER (Page 1)

GATE 2 Part No

SSL. Smart Valve Positioner.

9A5N Solid State CW Paddle

SonoMeter 30 Energy Meters

Verdi G-Series Family

Model 400ML Audible Information Device

QPL... Pressure Switches. Siemens Building Technologies HVAC Products

GDC 2 Wire Control System

Operating Instructions

Stand-Alone Bubble Detection System

Electrical operating instructions

TorMinal. Operating instructions V OCE-Rev.L_EN

10 switches simultaneously. The settings of the master sensor (source of copy) can be copied to the slave sensors. Reducing setting labor

Procedure Troubleshooting the Interconnect Cables

mn100 Analog Display

Genesis MX SLM-Series

Columbus Instruments

Sample Draw Oxygen Monitoring System (OMS) User Manual

SSR. Smart Valve Positioner.

User's Manual. Heavy Duty Dissolved Oxygen Meter. Model

KEG PUMP. Range of Electric Keg Pumps

DG100 Digital Depth Gauge and Timer. Training Module, Rev B

SVEA II GSM Connector User Manual

Wickets Installation Laundry Equipment Specific Installation Instructions 5/22/2009

INSTRUCTION MANUAL STATION CONTROLLER SC100 MOTOR PROTECTION ELECTRONICS, INC.

References 6 k thermal overload relays, adjustable from 0.11 to 16 A

OPERATING INSTRUCTIONS FOR

Manual. Kingpad mc-32 Edition. Bus system control pad for installation in the Graupner mc-32 transmitter. No Copyright Graupner/SJ GmbH

UBEC 1AT. AUTO TANK Fill System Installation, Operation, & Setup Instructions

CONTROL LOGIC DESCRIPTION DOCUMENT IC-410ND

Electrical operating instructions

Instruction Manual. PLT Series. 1. General Specification. 2. Installation. 3. Wiring. 4. Function. 5. Setting & Calibration

TANK MANAGER FOR TWO TANKS OPERATING MANUAL. 10/31/11 C-More T6C L color touch panel

ATM.ECO - Analog Pressure Transmitter

Verdi G-Series. High-Power Pumps for Ti:Sapphire Lasers and Amplifiers FEATURES

COMPRESSOR PACK SUCTION CONTROLLER TYPE: LP41x

MOYNO FLUID DETECTION CONTROL SERVICE MANUAL. Section: ACCESSORIES. Page: 1 of 8 Date: May 1, 1998 GENERAL

Operation manual Level sensor DC-LS-50 Operation Manual Level Sensor DC-LS-50

Heavy Duty Dissolved Oxygen Meter

CCT-7320/ROC-2313 Reverse Osmosis Controller

COMBAT SWIM BOARD. RJE International, Inc. RJE International January 16, TAC-300 Revision 4

IMPALA CONTROL PANEL CONVERSION KIT an ISO 9001:2008 Registered Company REV E 4/13/ IMPALA CNTRL PNL INST PG 1 OF 16

OPERATION AND INSTALLATION MANUAL

Fixed Ozone Monitor User Manual December, Automatikprodukter

Manual Weighingblock VB2 series and Uniscale

Built-in Purge Control Functions

SonoSelect 10 and SonoSafe 10 energy meters

RCD - Ultra-Rugged Differential Pressure Flowmeter

BUILT TO WIN PAINTBALL LOADER SPIRE III MANUAL

RPS900W Redundant Power Supply. Installation Guide.

ELECTRONIC CONTROL PANEL FOR 24VDC SECTIONAL DOORS AND ROAD BARRIERS SMARTY PLUS P TECHNICAL INSTALLATION MANUAL FOR AUTOMATIC GATES

[Instruments for vacuum measurement, checking and adjustment] 3

INSTRUCTION MANUAL. 840 Transmitter. Loop Powered Dissolved Oxygen Transmitter

JUMO dtrans p30 Pressure Transmitter

EasySas. The most advanced airlock electronics on the market. Recyclable product. Eco-design. Energy savings

Dimensions [All numbers in brackets are in millimeters.] K4-2 US (supplied) 1/2" Centered (Default)

CONSOLE-320 ENGLISH. 230A: CONSOLE-320 with cable data output Item 230B: CONSOLE-320 with cable + wireless radio data output

Ocean Technology Systems ComBox

AutoChanger Installation & User Guide Issue 2

FireHawk M7 Interface Module Software Instructions OPERATION AND INSTRUCTIONS

Aquavar SOLO 2 Frequently Asked Questions

COMBAT SWIM BOARD. RJE International, Inc. RJE International Feb 1, TAC-300 Revision 6

Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units

Operation Manual. Rev. C LPT Low Power Transmitter (Electrochemical Sensor)

Field Certification Certificate of Compliance

ECONORESS ELECTRONIC EPS & EPT - ENHANCED PRESSURISATION SET INSTALLATION OPERATION & MAINTENANCE DOCUMENTATION

Met One E-BAM Particulate Monitor

Model B Wire Wet Oxidant Gas Transmitter. 6 Iron Bridge Drive Unit 1 & 2 Gatehead Business Park

SAPCON. User Manual. Capacitance Continuous Level Indicator. . Introduction. . General Description. . Principle of Operation. .

Concentrate Distribution System (Stand Mounted) A-CDS-70-X & A-CDS-TANK-X-ST Industrial Drive, Orlinda, TN 37141

A4s Operation Manual

MULTIFUNCTIONAL CONTROL FOR GAS BURNING APPLIANCE

HAI UPB Wall Switch and Auxiliary Switch Installation and Operating Instructions

FLAMMABLE GAS SENSOR/TRANSMITTER

1 Characteristics: 2 Installation: INSTALLATIONguide. inteo SOLIRIS IB

User Manual. PolyGard DT V4. Electrochemical Carbon Monoxide Transmitter Serial No. DT December, 2008

Sensoric 4-20 ma Transmitter Board Operation Manual

Total solder points: 85 Difficulty level: beginner advanced MULTIFUNCTION RELAY SWITCH K8015 ILLUSTRATED ASSEMBLY MANUAL

Transmitter CS 21 Operation Manual

Operating instructions Capacitive sensor KIA (M30) / / 2010

outdoor CoCkpit

Transcription:

Reliable Golf Course Supplies Rev. A 6/30/98 OPERATION & INSTALLATION INSTRUCTIONS Congratulations on your purchase of Reliable Golf Course Supplies Tee Sentry. Your shipment should include the following items: 1) Main Control Unit with 6 power cable 2) Red pushbutton box with 6 interconnect cable 3) Green pushbutton box 4) Envelope w/mounting standoffs for Main Control Unit and black programming cable Standard Tee Sentry Operation The Tee Sentry requires the use of only two buttons - a Red Button located at the tee-off or initial blind shot area and a Green Button located in the landing area. Red Button - Prior to hitting a blind tee or fairway shot that is protected by the Tee Sentry, make sure to check the Main Control Indicators. IF THE RED INDICATOR IS PRESENT, STOP. THE PREVIOUS PARTY HAS NOT LEFT THE LANDING AREA AND IT IS NOT YET SAFE TO HIT. A Green indicator signifies that the landing area is clear and it is safe to proceed. After the last member of your group has hit their shot, push the Red button to turn the Main Control Unit to Red and proceed to the landing area. Green Button - When the last member of your group has hit his/her next shot and is safely leaving the landing area, push the Green button in the landing area to change the indicator in the Main Control Unit back to Green allowing the next group to hit. The Main Control Indicator will automatically return to green after an adjustable pre-set time even if the Green Button in the landing area is not pushed. Tee Sentry Installation In addition to the parts supplied with your Tee Sentry it will be necessary to have the following: mounting posts, power supply or battery, and 2/18 cable (for hardwire version only). 1. Mount the Main Control Unit a safe distance from, yet visible to, the area visible from which the blind shot will be hit. The Red/Green indicators can be easily seen from a distance of 100 feet. 2. Use the Red (+) and Black (-) battery clamps to connect the DC input cable (see fig. 1) to a 12VDC battery or power supply (not provided). The Green indicator will activate on power-up. OBSERVE POLARITY. 3. Plug the Red Button into the Main Control Unit using the cable provided. If it is necessary to mount the Red Button further away from the Main Control Unit than the length of wire provided, a standard 18 gauge stranded outdoor/burial wire should be used. 4. Hardwire version only - Connect the wire in the Main Control Unit for the Green Button Input (see fig. 1) to the interconnect cable to the green button (no polarity required). 5. The Tee Sentry comes with a selectable time out from 1 to 15 min. that is pre-set to a value of 9 minutes. The time out is set using the S1 four position dipswitch bank on the main circuit board in the Main Control Unit (see fig. 2 to set time out). If a group fails to push the green button upon leaving the landing area, the Main Control Unit automatically resets to green after the selected time out value has expired.

Tee Sentry Installation (cont ) 6. Mount the Green Button in an area convenient to golfers as they exit the landing area. For hardwire version connect the wire from the Green Button to the interconnect cable that runs back to the Main Control Unit (no polarity required). 7. Your Tee Sentry is now ready for use. Technical Specifications: 1. Main Control Unit........... 12VDC Bat or 1 Amp Regulated Power Supply 2. Wireless Buttons............. 3.0V Lithium (approx. 3-4 year life) DO NOT LOSE THE PROGRAMMING CABLE!!! If you have special needs it is possible to provide expanded functionality to your Tee Sentry. Please call 800-274-6815 for details. Reliable Golf Course Supplies has available 12VDC power supplies, Solar Charger/battery conditioner, and Lightening Suppression Modules for hardwired power situations. IMPORTANT!!! The radio receiver is a sophisticated microprocessor based control and can be damaged by power surges or brown out power situations. When using a battery it is necessary to maintain a charge above 10 Volts and protect from power spikes and lightening. Drawings: Figure 1 - Component layout Figure 2 - Tee Sentry Main Board Figure 3 - Wireless Transmitter Figure 4 - Wireless Receiver Programming the Transmitter to the Receiver (comes pre-programmed) - See Fig. 3 and 4 1. The Main Control Unit (Fig. 4) and the Wireless Pushbutton (Fig. 3) should be opened and sitting next to each other. Take the covers off the Wireless Receiver in the Main Control Unit and the Wireless Transmitter in the Pushbutton. Apply power to the Main Control. 2. Plug the enclosed black programming cable to the 3-pin Programming Header on the receiver board in the Main Control Unit (see Fig. 4). The cable has no polarity and can be plugged in either way. 3. Press the the programming button (labeled PGM) on the receiver for 1 second. This will cause the top light to flash as the receiver goes into program mode. If the top light goes to solid press the reset/delete button to clear whatever is in memory and repeat step 3. 4. Now connect the other end of the programming cable to the Wireless Transmitter in the pushbutton box and press the Reset button (Fig. 3). The program light on the receiver will go out and the valid/decode light will flicker intermittently indicating normal operation. 5. Test the entire unit for normal operation. Reliable Golf Course Supplies 643 Upper Glen Street Queensbury, NY 12804 800-274-6815

RED

Figure 4 Wireless Receiver Technical Specifications Dimensions (housing):...... 6.38 x 3.60 x 1.10 Weight:.................. 6.9 oz. Environmental: Operating Temperature:...... 32-120 F (0-50 C) Relative Humidity:......... 95% (non condensing) A. Electrical: Power Requirement:........ 11-14VDC Power Consumption:........ 120mA (max, relays activated) Typical:.................. 40mA (quiescent) FA404R output relay:....... Form C, 2A @ 120VAC, 2A @ 300VDC Receiver: Type:.................... frequency-hopping spread spectrum Operating Frequency:....... 902-928 MHz The VALID DEDCODE LED indicates transmissions from transmitters programmed to the receiver. Reliable Golf Course Supplies has available 12VDC power supplies, Solar Charger/battery conditioner, and Lightening Suppression Modules for hardwired power situations. B. Reset Button Access Cover: Insert small screwdriver in slot on left side A.. Hold cover lightly while prying. Install by inserting top latch and snapping in at bottom. Insert a small flat screwdriver behind pry point indicator nubs on top or bottom B. of the housing cover (4 places). Gently pry or twist the housing cover apart. Note: FA transmitters have non-volatile memory. It is not necessary to reprogram transmitters after losing power or changing batteries. Press the transmitter reset button to resotre programming. FAULT ALARM TX PGM