10/29/2012 13:08 3154795402 RL STONE SYR PAGE 01/05 --.,..~-.-_#-- Bid Price for; elty OF MON'rPELIER; VERMONT 1\ ~--. -----; Department of Public Worll:s i I HEAT EXCHANGERS FOR DISTRlCT HllA'l"lNG SYSTE~ I OCT 29 2012 \ i \ ~ i \.-S':~ ~:r\r(~r~.':'::: ~~~~~~p.,(3 j Item Ouantitv Un.it Price Extended Price SmallHX 2 t:.'i:''i:' 'RJ:'.T.nT.J RJ:'J:' ~1:'TnT.T Medium HX 0 Larzc HX 7 Per-Unit Bid Pri.ce for Additional Purchases: Item Unit Price Small HX MediumHX Large HX Print the following information: Name of Vendor; R. L. STONE CO. INC. Contact: ~l)~!>jirns1ey_ DEive Syracuse, NY 13210 Phone Number: 888-404-8882 VENDOR OFFERING #BIOTHX40 VENDOR OFFERING #B80HXI02 VENDOE OFFERING #BIOTHX36 VENDOR OFFERING #B35HX30 VENDOR OFFERING #B120THX120 VENDOR OFFERING #B50LX28 VENDOR OFFERING #B50LX58 VENDOR OFFERING #B50HX238 VENDOR OFFERING #B50LXS8 Price $365.~O Net Ea~h Price: $921.96 Net Each Price: $36~.40 Net Each Price: $921.96 Net Each Price: $2085.40 Net Each Price: $1418.30 Net Each Price: $1820.75 RetEach '~rice: '$4226~85 Net Each Price: $1820.75 Net Each, d L Stone Co-New Engtan R.. tc Office' \ 1~ Ainsley Drive Corpora.,- 0 S),rilC\lse, N): 1321 _ 02 re\~888-404-8882 Fax: 315-419 54 BID DATE: to!26!20j.2 -!!-
10/29/2012 13:08 3154795402 RL STONE SVR PAGE 02/05 TItle: Montpelier District Heating I. Hallam.ICS.. r".uo O~t~; Pagett: 40f7 of 195 psig in one circuit with zero pressure in the alternate circuit. G, Provide a mounting bracket for either wall or floor mount, 2.2 For each size heat exchanger, select the thermodynamic conditions listed in this specification for each size that represents the biggest challenge to provide to the City. Provide performance data for that particular unit for each condition listed. This specification is attempting to procure heat exchangers and their performance at different operating conditions on the Building side, 2,3 Small Size Heat Exchanger - 125 MBH 250 MSH "Standard 20 degf Deltaj Bullding Side Hot Side (District) Supply Degree F 220 BIOTHX40 Hot Side (District) Flow GPM 10.3 Building Flow GPM 25,6 Building PO PSI <5,0. 250 MBH -10 degf Delta, BuildIng Side Feature /Characteristic Units Design Value Vendor Offering Hot Side (District) Supply Degree F 220 B80HX102 Hot Side (District) Return Degree F ' 1,70 Hot Side (District) Flow GPM 10,3 Hot Side (Dstrict) PD PSI <5,0 Building Flow GPM 51,3 Building PO PSI <5,0 BRAZED PLA TE I-TEAT EXCHANGERS R.L. Stonlt~Co~Ne:".;England Corporate Office j 1'" Ainsley Drive Syracuse, N'i 13210 Tel: 888-404-8882 ~!=ax' 315-479-5402 15757-4
10/29/2012 13:08 3154795402 RL STONE SYR PAGE 03/05 Hlllbm<'ICS Montpelier District Heating I Hallam.leS Tltt~, 15757 ~ Brazed Plate Heat Exchangers i 1&8ue D:lto; October 12, 2012 50f7 250 MBH -low Temperature, Building Side Hot Side (District) Supply Degree F 220 1B1OT_HX36 Hot Side {District) Return Degree F 170 Hot Side (District) Flow GPM 10.3 Building Supply Degree F 160 Building Flow GPM ~5.6 2.4 Medium Size Heat Exchanger- 500 MBH t= 500 MBH - Standard 20 degf Delta; BLlilding Side Hot Side (District) Supply Degree F 220 B35HX30 Hot Side (District) Flow GPM 20.6 Hot Side (Dstrict) PO PSI <5.0 Building Flow GPM 51-2 500 MBH - 10 degf Delta, Building Side Hot Side (District) Supply Degree F 220 B120THX120 Hot Side (District) Flow GPM 20.6 Hot Side (Dstrlct) PD PSI <5.0 Building Flow GPM 102.6 BRAZED PLATE HEAT EXCHANGERS R.L. Stone co-new EDgl~Dd Corporate Office' J 1" Ainsley Dnve. Syracuse, NY 13210 157)7~5 Tel: 888--404-$882 ~ ~ay.;315-479-5402
10/29/2012 13:08 3154795402 RL STOt'-1E SYR PAGE 04/05 Title: Montpelier District Heating Hallam-ICS I, I i Oetober 1Z, 2012 Page #~ 60f7 500 MBH ~low Temperature, Building Side Feature!Characteristic Units Design Value Vendor Offering Hot Side (District) Supply Degree F 220 BSO+-X28 Hot Side (District) Flow GPM 20.5 Hot Side (Dstrict) PO PSI <S.O Building Supply Degree F 160 Building Flow GPM Sl 2.5 Large Size Heat Exchanger -1000 MBH 1000 MBH - Standard 20 degf Delta, Building Side Feature ICharacteristic Units Design Value Vendor Offering Hot Side (District) Supply Degree F 220 RC;m,YC;.R Hot Side [Dstrict] PD PSI <5.0 Building Flow GPM 102.~; 1000 MBH n 10 degf Delta, Building Side Hot Side (District) Supply Degree F 220." Building Flow GPM 205.2., BRAZED PLATE HEAT EXCHANGERS R.L. Sto:ne Co~NewEngland Corporate Office' 1 15 Ainsley Drive Svracuse, tn, j 32l 0 t 5757-6 Te!: 98e-40t'~8P,H2.~,'!~)~: 31.5-479-5402
10/29/2012 13:08 3154795402 RL STONE SY'R PAGE 05/05 NRlillmo'TCS Montpelier. I District J-Ieating!. I. Hallam-ICS I tssue o.~; Octo~1~, 2012 TItle: P8g"'~ 7 of7 1000 MBH ~low Temperature, Building Side Feature /Characteristic; Units Design Value Vendor Offering Hot Side (District) Supply Degree F 220 B50LX58 Building Supply Degree F 160. Building Flow GPM 102 Building PO PSI <5.0 PART 3 - EXECUTION 3.1 DELIVERY A. Ship to Owner location when demanded by Owner. END OF SECTION 15757.' ill. Ston.el Co New England Corporate Offlce: J Ij Ainsley Drive Syrac 1St, ~'.Jy 1"32\0 faj; 888-4(V!-:;:;Rr.:::: " "':-'!~.',: < <:: <l,7r.p::41't, ""I".UL BRAZED PLATEHEA T EXCHANGERS -------