Loctite EQ VA25 Dispense Valve 50 Bar IDH Number EQUIPMENT Operation Manual

Similar documents
EQUIPMENT Operation Manual

EQUIPMENT Operation Manual. Loctite Stainless Steel Poppet Valve Part Number

EQUIPMENT OPERATION MANUAL. Loctite Dispense Valve Manual

Loctite Integrated Semi-Automatic Dispenser Dual Channel with Low Level Sensor

EQUIPMENT. Bond-A-Matic Reservoir Systems / / / / OPERATION MANUAL

TL-12 FLUSH TANK. Manual Ref. # MN-??? Polyurethane Machinery Corp. REVISION 1.0

NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE

Back Pressure Regulator

453 Series Steam Heated Vaporizing Regulator

STC 2KS/2KD Series Stainless Steel Angle Seat Valve

ACCU-MIX 1200 / / 26270

APCO ASU-SCAV & ASU-CAV SINGLE BODY COMBINATION AIR VALVES

INSTRUCTIONS PARTS LIST

ULTRA HIGH PRESSURE PAINT GRATE CLEANER FCT-JS OPERATION AND MAINTENANCE MANUAL

Interface Devices, Inc. Hydraulic Mini Mule

CSA Sample Draw Aspirator Adapter Operator s Manual

Model No Product Name Handpiece Only Complete System

DISPENSING VALVE MODEL VDP100 INSTRUCTION MANUAL

AIR INLINE METAL SHEAR

SIX R (P ) AND SEVEN R (P ) POSITION CYLINDERS Service Information

RK-IR Sample Draw Aspirator Adapter Operator s Manual

P5523. Users Manual. Liquid to Gas Separator. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.

User Instruction Manual

Model ASSEMBLY and OPERATING INSTRUCTIONS

Cylinder Tilt Saddle Instruction Manual

INSTRUCTIONS FOR MODELS UPH & UPHS HIGH FLOW, HIGH PURITY GAS REGULATORS

INSTRUCTION MANUAL GAS TRAK

SPECIFICATIONS Type: Twin stack, single phase Tank: 4 gallon Air Output: PSI; PSI Max PSI: 125 PSI HP: 1.

GILMONT ACCUCAL FLOWMETERS

Index Table. Model 794. Installation, Operating and Maintenance Instructions

CLEMENTS. ANA Oxygen Regulator with Yoke Connector. User Manual. Manual No. ANA Issue 1

INSTRUCTIONS PARTS LIST

Tridak Model 1050 User Guide

SC HYDRAULIC ENGINEERING CORPORATION

FLOW CONTROL & AIR PILOT SWITCH VALVES

CHEMICAL INDUCTION KIT (Pt.No Issue 6, October 2015)

3800 SERIES END SUCTION PUMP REPAIR PARTS INDEX. Model Model 3804

Tridak Model 1060 User Guide. Syringe Filling System

Yoke Block Instruction Manual

Color/Catalyst Dispense Valves

Freedom8 ShoeBox Compressor Manual

Pressure Dump Valve Service Kit for Series 2300 Units

3" UC Ultra-Chuck Durable Lightweight Air Inflated Bladder Chuck Operation/Repair Manual. (76.2 mm) DOUBLE E COMPANY, INC.

Pulse Blow Series Offers Energy Savings for Air-blowing Procedures

SSFU SUPER SPRAYFAST UNIVERSAL ADHESIVE APPLICATOR

INSTRUCTIONS FOR FM4460N SERIES HIGH PRESSURE, METAL TUBE FLOWMETERS

INSTRUCTIONS PARTS LIST U.S. PAT: 6,874,404; 6,516,707; 6,223,645

ATD /8 x 50 Retractable Air Hose Reel Owner s Manual

ROPV R40 E Series User Manual

RK LEL Sample Draw Aspirator Adapter Operator s Manual

GETZ EQUIPMENT INNOVATORS RECOVERY SYSTEM CLEAN AGENT FE-36 / HALOTRON 1 PART NO. 4G59751 OPERATIONS MANUAL

Welker Sampler. Model GSS-1. Installation, Operation, and Maintenance Manual

PERSONAL AIR BREATHING UNIT

INSTRUCTIONS FOR MODEL SSC LOW DELIVERY PRESSURE GAS REGULATORS

GETZ EQUIPMENT INNOVATORS PART NO.: 9G59554 MODEL: MS 36 SC-R HYDROSTATIC TEST PUMP

INSTRUCTIONS FOR MODELS SG3897 AND SG3898 CROSS PURGE ASSEMBLIES

Hygienic Bubble Trap Installation and Operations Manual

High Pressure Inlet Kits for CONCOA BlendMites and BlendMasters

D Series Air and Water Kit Part# 02550

J Air and Water Kit Instructions Part# 02584

Operation Manual - PN A MENSOR MODEL 73 SHOP AIR BOOSTER

Steel Spring Driven Reel Instruction Manual

TactAir PCP Fill Kit/Adapter. Operation Manual

INDUSTRIAL VALVES MODELS: C62-A; C62-D. INSTRUCTION MANUAL Installation Operation Parts Service DIAPHRAGM BYPASS PRESSURE REGULATING VALVES

Yoke Block Instruction Manual

Tube Tugger. Operating and Maintenance Instructions. Semi-Continuous Tube Extractor.

CATALYZER TM 2K 10:1 RATIO Pump

Cocoa Patio Pond with Lit Spillway

CF-SERIES HIGH FLOW REGULATORS

MODEL 100 NITROGEN INFLATION CART

THE MF-400 SERIES. Operating and Service Manual. Series includes all variants of MF-400/401

THE HF-300 SERIES. Operating and Service Manual. Series includes all variants of HF-300/301

PENBERTHY SUBMERSIBLE AUTOMATIC SUMP DRAINER INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

2K 600mL Dispense Guns with Built-In Retainers

KJ4000 Operating Instructions & Parts Manual NSN

INSTRUCTIONS FOR MODEL SG6500 GAS HEATERS

Installation, Operation, and Maintenance Manual. Welker Constant Pressure Cylinder With Solid Indicator (Non-mixer) Model CP-30SI

FLANGED MULTI-PORT BALL VALVES

FLANGED TWO-PIECE BALL VALVES

Installation Instructions JATCO Environmental Protection Tank Model J-5000CX

CB 350. Spare parts list. Hydraulic concrete buster. CB 350 s/n DEQ Construction Tools GmbH No

SERVICE MANUAL. Technical Bulletin No GEOPROBE GH40 HYDRAULIC HAMMER. PREPARED: February, REVISED: April, 2002 A DIVISION OF KEJR, INC.

Models: C62/63/64-A/D

HAYWARD FLOW CONTROL Series PBV Back Pressure Valve and Series RPV Pressure Relief Valve INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS

PCS 340 Core Saturator : 115 Volt : 230 Volt. Instruction Manual

Installation, Operation, and Maintenance Manual

FLANGED TWO-PIECE BALL VALVES

INSTALLATION & MAINTENANCE INSTRUCTIONS

WEATHERIZING INSTRUCTIONS

User Operation Manual and Safety Instructions

Instructions Parts List

accidents which arise due to non-observance of these instructions and the safety information herein. SPECIFICATIONS

Techcon Systems TS1258 Pressure Pot

4-in-1 Professional Inflator Kit

T-900 Series. Operation Manual for T-960, T-965, T-970, T-975, T975-CPF

G7S Hand Pump Owner s Manual

Owner s Manual W Automatic Aboveground Pool Cleaner

accidents which arise due to non-observance of these instructions and the safety information herein. SPECIFICATIONS

OPERATION / 3Z9305G 1:1 RATIO TRITON / Spray Packages / / / List of Models, page 2 / / / 100 psi (7 bar, 0.7 MPa) Maximum Working Pressure

INSTALLATION MANUAL Matheson Tri-Gas Cabinet Enclosures

Transcription:

Loctite EQ VA25 Dispense Valve 50 Bar IDH Number 1838885 EQUIPMENT Operation Manual

Contents 1. PLEASE OBSERVE THE FOLLOWING...3 1.1 EMPHASIZED SECTIONS...3 1.2 ITEMS SUPPLIED...3 1.3 FOR YOUR SAFETY...3 1.4 FEATURE...3 1.5 USAGE...3 2. DESCRIPTION...4 2.1 SPECIFICATION...4 2.2 VALVE COMPONENTS AND DIMENSIONS...4 3. UNPACKING AND INSPECTION...5 4. TYPICAL SYSTEM SETUP...5 5. SETUP AND OPERATION...5 5.1 CONNECTION...5 5.2 OPERATION...6 5.3 Shutdown 7 5.4 Returning to Operation... 7 6. TROUBLESHOOTING...7 7. SPARE PARTS/ ACCESSORIES...8 8. WARRANTY...9 2

1. Please Observe the Following 1.1 Emphasized Sections WARNING! Refers to safety regulations and required measures that protect the operator or other persons from injury or danger to life. Caution! Emphasizes what must be done or avoided so that the unit or other property is not damaged. Notice: Provides recommendations for better handling of the unit during operation or adjustment, as well as for service activities. 1.2 Items Supplied 1 50Bar/5mm Dispense Valve 2 2 meters each of clear and blue air line tubing 1 Operation Manual 1.3 For Your Safety For safe and successful operation of the unit, read these instructions completely. If the instructions are not observed, the manufacturer can assume no responsibility. Observe general safety regulations for the handling of chemicals! Observe manufacturer s instructions! Request a safety data sheet for the product used! When working with pressurized air, wear protective glasses! This valve operates under maximum air pressure input is 6 bars, do not exceed! This valve operates under maximum fluid pressure is 50 bars, do not exceed! While under warranty, the unit must be repaired by an authorized Loctite brand service representative. 1.4 Features Maximum working fluid pressure: 50 bars (725 psi) Bubble free, no-drip dispensing High resolution stroke adjustment 1.5 Usage The Loctite EQ VA25 Dispense Valve is a double acting dispense valve that is used to dispense medium to high viscosity silicone, MS polymer and urethane products. It can operate at fluid pressures up to 50 bars and features inherent suck-back that draws a small amount of product back at the end of each stroke. 3

2. Description 2.1 Specification Pneumatic Supply Quality Size Free Flow Orifice Inlet Thread Product Fluid Pressure Weight Max. 6.8 Bars (max. 100 psi) Filtered 10μm, oil free, non-condensing If the required quality is not achieved, install a Loctite filter regulator 88649 (97120) 8.3 length x 1.2 diameter (210 mm x 31 mm) 0.20 diameter (5 mm) ¼-19 BSPT Female Max. 50 bars (max. 725 psi) 0.54 kg 2.2 Valve Components and Dimensions 1.2 [31] STROKE ADJUSTMENT.4 [9] VALVE OPEN PORT D M5 X 0.8 THREAD 3.9 [99] VALVE CLOSE PORT C 4.8 [121] 8.3 [210] 1/2-14 BSPP WITH 60 JIS CONE PORT A KIT # 1553588.8 [20] M6 X 1.0 X 8 DP. MOUNTING HOLES 1/4-19 BSPT 1.3 [34] FLUID OUTLET TIP ADAPTER PORT A KIT # 1119605 1/4-19 BSPT.8 [21] 4

Label P/N 8901461 Cartridge Pressure UP Cartridge Cylinder DOWN 3. Unpacking and Inspection Carefully remove the system from its shipping carton, and inspect it for any signs of damage. Any damage should be reported immediately to the carrier. Refer to the list of parts supplied (page 3), and compare to the contents. Report any missing parts promptly to the Loctite customer service department at 1-800-LOCTITE (562-8483) 4. Typical System Setup Plant air must be properly filtered and dry. Ref: 88649 (97120) Filter / Regulator Constant Air Lines 961819 (97101) Controller Product Feed Line Pulsed Air Lines 1838885 EQ VA25 DISPENSE VALVE High Pressure Cartridge Dispenser Item # 1046901 Serial # 1046901 High Pressure Cartridge Dispenser 5. Setup and Operation 5.1 Connection Connect the 4 mm O.D. airline to the air fitting port C and the other end of airline will be connected to the normally opened port of solenoid valve. Connect the 4 mm O.D. airline to the air fitting port D and the other end of airline will be connected to the normally closed port of solenoid valve. Connect the fluid reservoir feed tube to the fluid inlet port A and tighten it well. Make sure the tube was cut at a right angled cut. Tube cutter is recommended. 5

5.2 Operation With the Semi-Automatic Controller 88649 (97101) set up and connected to the valve, and the High Pressure Cartridge Dispenser 1046901 connected as shown on page 5, load the High Pressure Cartridge Dispenser per High Pressure Cartridge Dispenser Operating Manual instructions. CAUTION: Always treat a pressurized reservoir with respect, and check air gauge to ensure pressure is at zero before opening. After filling, check to be certain the system is sealed with no leaks. Before proceeding, check the following: 1. Be sure all the connections are tight. 2. Set the valve control air pressure at a minimum of 60 psi (4 Bars). 3. Actuate the valve long enough to fill the valve, start liquid flow and purge air from the dispensing tip. If a small tip is used, it may need to be removed from the valve during purging. Then fill the tip hub with fluid and install on the tip adapter so it is free of air. To open the valve: 1. Apply air pressure to OPEN air port (Port D) on the valve, and remove pressure from the CLOSE (Port C) air port on the valve. 2. Maintain air pressure on the OPEN (Port D) air port to keep the valve open. To close the valve: 1. Apply air pressure to CLOSE air port (Port C) on the valve, and remove pressure from the OPEN (Port D) air port on the valve. 2. Maintain air pressure on the CLOSE (Port C) air port to keep the valve open. To adjust the stroke: 1. Rotate the stroke adjustment (section 2.2) to change the length of the stroke. This will affect the product flow rate. 2. Rotating the stroke adjustment toward the stop nut will decrease the flow rate. 3. The unit ships pre-set to maximum flow. 6

5. Setup and Operation 5.3 Shutdown 1. To prevent the product from coming in contact with air, put an end-cap on the nozzle or keep the nozzle in grease. 5.4 Returning to Operation 1. Remove the end-cap from the nozzle. 2. If needed, purge the product feedline and dispensing valve. Returning to Operation After Longer Periods of Non-use. 1. Remove the Luer-Lock tip cap. 2. Purge the product feedline and dispensing valve. 6. Troubleshooting Problem Possible Cause Correction No product or too little product Product feedline not correctly connected Correctly connect the product feedline Pneumatic hose not correctly connected Correctly connect the pneumatic hose Controller incorrectly adjusted Check the controller (see operating instructions for the controller) HPCD not switched on or pressure is too low Check the HPCD (see operating instructions for the HPCD) Valve operating pressure is too low Increase air pressure to 60psi (4 bar) minimum Air bubble in product Inconsistent deposits The dispensing tip is clogged Curing in the product feedline and/or in the dispensing valve Air in the dispensing valve/product feedline The air pressure controlling the valve and/or HPCD is fluctuating The open time of the valve timer must be constant Replace the tip Replace the product feedline and clean dispensing valve head Purge the product feedline, dispensing valve and dispensing tip Check to be make sure the air pressures are constant Check to be sure the valve controller is providing a consistent output 7

7. Accessories and Spare Parts Number Loctite Item Number Description 1 1119605 Fluid Outlet Tip Adapter 2 1251150 Outlet Seal, Acetal, Outlet Seal Kit 3 1251150 Stop Pin, Outlet Seal Kit 4 1251161 O-ring Housing (3), PTFE, Shaft Seal Kit 5 1251161 O-Ring (3), Viton, Shaft Seal Kit 6 1251161 O-Ring Seal (2), Shaft Seal Kit 7 Seal Cap 8 M4 Hex Nut 9 Valve Body 10 Compression Spring 11 Valve Piston 12 1251162 O-Ring (2), Viton, Actuator Seal Kit 13 1251162 O-Ring, Viton, Actuator Seal Kit 14 1251162 O-Ring, Viton, Actuator Seal Kit 15 Valve End Cap 16 Stroke Lock Nuts (2) 17 1553588 Fluid Inlet Fitting (Not Shown) 18 Hex Nipple ¼-19 BSPT, (Not Shown) 19 Female Hex Coupling ¼-19 BSPT, (Not Shown) 20 Male Elbow 4mm Tube x M5 x 0.8 Thread 21 1070269 Robot Valve Mounting Bracket Kit 22 1241821 Fluid Hose, 1 Meter 23 1241780 Fluid Hose, 2 Meters 8

8. Warranty EQUIPMENT WARRANTY For Loctite 1838885 EQ VA25 Dispense Valve Henkel expressly warrants that all products referred to in this Manual for Loctite Dispense Valve 1838885 (hereafter called Products ) shall be free from defects in materials and workmanship. Liability for Henkel shall be limited, at its option, to replacing those Products which are shown to be defective either in materials or workmanship or to credit to the purchaser the amount of the purchase price thereof (plus freight and insurance charges paid therefore by the user). The purchaser s sole and exclusive remedy for breach of warranty shall be such replacement or credit. A claim of defect in materials or workmanship in any Products shall be allowed only when it is submitted to Henkel in writing within one month after discovery of the defect or after the time the defect should reasonably have been discovered and in any event, within twelve months after the delivery of the Products to the purchaser. No such claim shall be allowed in respect of Products which have been neglected or improperly stored, transported, handled, installed, connected, operated, used or maintained or in the event of unauthorized modification of the Products including, where products, parts or attachments for use in connection with the Products are available from Henkel, the use of products, parts or attachments which are not manufactured by Henkel. No Products shall be returned to Henkel for any reason without prior written approval from Henkel. Products shall be returned freight prepaid, in accordance with instructions from Henkel. NO WARRANTY IS EXTENDED TO ANY EQUIPMENT WHICH HAS BEEN ALTERED, MISUSED, NEGLECTED, OR DAMAGED BY ACCIDENT, OR IF THE SYSTEM USED TO DISPENSE ANY LIQUID MATERIAL OTHER THAN LOCTITE PRODUCTS. EXCEPT FOR THE EXPRESS WARRANTY CONTAINED IN THIS SECTION, HENKEL MAKES NO WARRANTY OF ANY KIND WHATSOEVER, EXPRESS OR IMPLIED, WITH RESPECT TO THE PRODUCTS. ALL WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, AND OTHER WARRANTIES OF WHATEVER KIND (INCLUDING AGAINST PATENT OR TRADEMARK INFRINGEMENT) ARE HEREBY DISCLAIMED BY HENKEL AND WAIVED BY THE PURCHASER. THIS SECTION SETS FORTH EXCLUSIVELY ALL OF LIABILITY FOR HENKEL TO THE PURCHASER IN CONTRACT, IN TORT OR OTHERWISE IN THE EVENT OF DEFECTIVE PRODUCTS. WITHOUT LIMITATION OF THE FOREGOING, TO THE FULLEST EXTENT POSSIBLE UNDER APPLICABLE LAWS, HENKEL EXPRESSLY DISCLAIMS ANY LIABILITY WHATSOEVER FOR ANY DAMAGES INCURRED DIRECTLY OR INDIRECTLY IN CONNECTION WITH THE SALE OR USE OF, OR OTHERWISE IN CONNECTION WITH, THE PRODUCTS, INCLUDING, WITHOUT LIMITATION, LOSS OF PROFITS AND SPECIAL, INDIRECT OR CONSEQUENTIAL DAMAGES, WHETHER CAUSED BY NEGLIGENCE FROM HENKEL OR OTHERWISE. Henkel Corporation One Henkel Way Rocky Hill, CT 06067-3910 USA Henkel Capital, S.A. de C.V. Calzada de la Viga s/n Fracc. Los Laureles Loc. Tulpetlac, C.P. 55090 Ecatepac de Morelos, MEXICO Henkel Loctite Korea 8F, Mapo Tower, 418, Mapo-dong, Mapo-gu, Seoul, 121-734, KOREA Henkel Canada Corporation 2515 Meadowpine Boulevard Mississauga, Ontario L5N 6C3 Canada Henkel Singapore Pte Ltd Blk 5002 Ang Mo Kio Ave 5 #03-12 TECHplace 2, 569871 SINGAPORE Henkel Japan Ltd. 27-7 Shin Isogo-cho, Isogo-ku Yokohama, 235-0017 JAPAN Henkel Corporation Automotive/Metals HQ 32100 Stephenson Awy, Madison Heights, MI 48071 USA Henkel (China) Company Ltd. No. 928 Zhang Heng Road, Zhangjiang, Hi-Tech Park, Pudong, Shanghai, China 201203 www.equipment.loctite.com Loctite is a trademark of Henkel Corporation, U.S.A. Copyright 2006. Henkel Corporation Teflon is a registered trademark of E.I. DuPont de Nemours Co., Inc. All rights reserved. Data in this operation manual is subject to change without notice. Manual P/N: 8904037, Date: 10/16/2013 9