OOC RGA. Ion Pump 400 l/s. 8" ports with baked viton o-ring seals. Welsh rotary roughing pump 650 l/s manual isolation valve.

Similar documents
LASER INTERFEROMETER GRAVITATIONAL WAVE OBSERVATORY - LIGO - CALIFORNIA INSTITUTE OF TECHNOLOGY MASSACHUSETTS INSTITUTE OF TECHNOLOGY

The Principles of Vacuum Technology

BEST KNOWN METHODS. Transpector XPR3 Gas Analysis System. 1 of 6 DESCRIPTION XPR3 APPLICATIONS PHYSICAL INSTALLATION

Introduction of Vacuum Science & Technology. Diffusion pumps used on the Calutron mass spectrometers during the Manhattan Project.

LOW PRESSURE EFFUSION OF GASES revised by Igor Bolotin 03/05/12

This educational seminar discusses creating, measuring, and troubleshooting Rough Vacuum.

LOW PRESSURE EFFUSION OF GASES adapted by Luke Hanley and Mike Trenary

A Journal of Practical and Useful Vacuum Technology. By Phil Danielson

Vacuum Science Techniques and Applications Dan Dessau Adv. Lab 2007

LCLS Heavy Met Outgassing Tests * K. I. Kishiyama, D. M. Behne Lawrence Livermore National Laboratory

at NIST: ultra-low outgassing rates

Canadian Light Source Inc. Vacuum Component Leak Test Technical Procedure

Practical approach and problems in in-situ RGA calibration

Mass Spec will not Autotune

Short Introduction to Cryo-Pumps and Refrigerators. Dr Graham Rogers Leybold UK Ltd.

The Helium Leak Detector

REPRODUCIBILITY IN OPTICAL THIN FILM PROCESSING PART 1, THE VACUUM AND PUMPING

AGILENT TURBOMOLECULAR PUMPS MEASUREMENT METHODOLOGY

The Broadest Gauging Line in the Industry

Memorandum Background: Results and Discussion:

Vacuum Systems and Cryogenics for Integrated Circuit Fabrication Technology 01

Introductory Lab: Vacuum Methods

D R A F T. Operating Procedures for the NPDGamma Liquid Hydrogen Target at the BL 13. Version 1.00

High Performance Mass Spectrometers

Vacuum. Dry Turbo Pumping Stations. Roughing Pumps for 1 K Helium Pots and Lambda Refrigerators. Hermetically Sealed Pumps for He3 Recirculation

Go/no-go test for the acceptance of components for unbaked vacuum sectors

DEVICES FOR FIELD DETERMINATION OF WATER VAPOR IN NATURAL GAS Betsy Murphy MNM Enterprises 801 N. Riverside Drive Fort Worth, Texas 76111

Leak Checking Large Vacuum Chambers

Chapter 8: Cryo-sorption pumps

DRAFT. Operating Procedures for the NPDGamma Liquid Hydrogen Target in TA-53, Building MPF-35

A NOVEL SENSOR USING REMOTE PLASMA EMISSION SPECTROSCOPY FOR MONITORING AND CONTROL OF VACUUM WEB COATING PROCESSES

Gun Vacuum Performance Measurements February 2003

MASSIVE TITANIUM SUBLIMATION PUMPING IN THE CESR INTERACTION REGION *

Leak Detection. Kirsten Zapfe, DESY CAS Vacuum in Accelerators Platja D Aro, May 21, Special thanks to S. Holm, N. Mildner and A.

School of Chemistry SOP For Operation Of Glove Boxes

Improving the Measurement Accuracy of Water Partial Pressure Using the Major Constituent Analyzer

Resist round robin ELETTRA

1)! DO NOT PROCEED BEYOND THIS MARK

ASPECTS OF VACUUM TECHNOLOGY. (a) To see something of the operation of vacuum pumps; Then, we will use the vacuum system for one of two experiments:

PHOENIX L300i Best-in-class Helium Leak Detectors

Major Design Features

Revision 2013 Vacuum Technology 1-3 day Good Vacuum Practice 1 Day Course Outline

Residual Gas Analysis Systems for Industry

Vacuum System at IUAC

Low-Power Atmospheric Gas Sampling System Based on ART MS Sensor and NEG-Ion Pump

Dilution Refrigerator manual

Leaks, contamination and closed loop control how RGAs make coating processes more profitable

How To Use Getters and Getter Pumps

The Experts in Vacuum Solutions

Applications of a Magnetic Sector Process Mass Spectrometer to the Analysis of Variable Vacuum Samples

Level MEASUREMENT 1/2016

CHEM 355 EXPERIMENT 7. Viscosity of gases: Estimation of molecular diameter

VIC offers a variety of Calibrated Gas Leaks

Choosing a Quadrupole Gas Analyzer Application Note #9

Total Pressure Measurement Using Residual Gas Analyzers

3200 Dwight Road Suite #100 Elk Grove, CA Ph: Fax: GNB Corporation

Baffles and Traps Cryotrap

EMISSION CHAMBERS. Bulk and Surface Emission Detection for the RAD7 User Manual

Succeeding with Production Air Leak Testing Methods. Paul Chamberlain President, CEO

Multiphase MixMeter. MixMeter specification. System Specification. Introduction

INSTRUCTIONS. VP-100 Ion Pump. Model / R001

ACCELERATOR VACUUM PROBLEMS: IN-LINE OIL TRAPPING BETWEgN THE STANFORD LINEAR ACCELERATOR AND THE BEAM SWITCHYARD

Instruction Manual. Pipe Friction Training Panel

E SC 412 Nanotechnology: Materials, Infrastructure, and Safety Wook Jun Nam The Pennsylvania State University

Soil Water Characteristic Curve (SWCC) Using the WP4C

Technical Specifications of Hydrogen Isotope Handling and Recovery System

Operating Procedures for Metal Evaporator I

Numerical Tools for LCLS-II Vacuum Systems

FPG8601 Force Balanced Piston Gauge

The Discussion of this exercise covers the following points:

2 Switching off ECRIS 3. 4 Acquire Beam Spectrum 4. 6 Vent Instrument Chamber 5. 7 Pump down Chamber 5. 8 Baking out Chamber 5.

-6- THE DIII-D MAGNETIC FUSION TOKAMAK OUTGASSING TESTS ON MATERIALS USED IN. KaLm HOLTROP, M. HANSINK, and AmGm KELLMAN DECEMBER 1998 ATOMICS GENE-L

Quadruple mass spectrometers (transducer type)

Standard Operating Manual

Vacuum Simulations of the KATRIN Experiment

Matching Vacuum Pump to Process

The new PTB standard for dynamic vacuum pressures

HEATEC TEC-NOTE. Setting Siemens Pressure Transmitter. Used on Heatec Vertical Asphalt Tanks. Publication No , Revised

Determination of Air Density with Buoyancy Artefacts

Measuring mass flows in hermetically sealed MEMs & MOEMs to ensure device reliability

Development of Cleaning and Processing Techniques for UHV/XHV at Daresbury Laboratory Keith Middleman

AFC. SDPROC and AFC Analog Mass Flow Controller ANALOG MASS FLOW CONTROLLERS. Principles of Operation. Design Features

A Reliable and Tracer Gas Independent Leak Detector for Food Packages

Sizing Pulsation Dampeners Is Critical to Effectiveness

VS Series Leak Detectors for Vacuum Furnaces LEAK DETECTION FOR VACUUM FURNACES

The HumiPyc ( Model 2) - Gas Pycnometer; Density, Moisture, Permeation Analyzer; Filter Integrity Tester; RH sensor Calibrator

ELEVATION CORRECTION FACTORS FOR RADON MONITORS*

The University of Hong Kong Department of Physics Experimental Physics Laboratory

Customer Responsibilities. Important Customer Information Series Q-TOF LC/MS Systems Site Preparation Checklist

Performance of the Liquid Hydrogen Target

PG7000 high line differential mode for defining differential pressure at line pressures above atmospheric pressure (PG7000 V2.

Oxford Instruments Austin, Inc.

(PTP) REMOVE PROBE SPINUP GAS/VAC. LINES (HORIZ.)

Air entrainment in Dip coating under vacuum

GPP model GPPT model GPC model CLP model

Pump out insert (condenser and still lines) overnight with turbo pump

st Symposium of Northeastern Accelerator Personnel A TIMESHARED FORELINE AND ROUGHING VACUUM SYSTEM. Oak Ridge, TN

AMT-Ex Dewpoint Transmitter

Vacuum Science and Technology in Accelerators

6 SMOG2 Gas Feed System Gas

Transcription:

LASER INTERFEROMETER GRAVITATIONAL WAVE OBSERVATORY - LIGO - CALIFORNIA INSTITUTE OF TECHNOLOGY MASSACHUSETTS INSTITUTE OF TECHNOLOGY Technical Note LIGO-T000126-00- R 11/20/2000 Vacuum pressure at the 40 Meter and the new Output Optic Chamber D. Ugolini, S. Vass, A. Weinstein This is an internal working note of the LIGO Project. California Institute of Technology Massachusetts Institute of Technology LIGO Project - MS 18-34 LIGO Project - MS NW17-161 Pasadena CA 91125 Cambridge, MA 02139 Phone (626) 395-2129 Phone (617) 253-4824 Fax (626) 304-9834 Fax (617) 253-4824 E-mail: info@ligo.caltech.edu E-mail: info@ligo.mit.edu WWW: http://www.ligo.caltech.edu/ file /home/ajw/docs/t000126-00.pdf

Vacuum pressure at the 40 Meter and the new Output Optic Chamber Dennis Ugolini, Alan Weinstein, Steve Vass November 20, 2000 Abstract We describe the procedure by which we pumped down the newly-commissioned output optic chamber for the 40 Meter upgrade, and evaluated its total outgassing rate. Comparing this with the measured outgassing rate of the entire 40 Meter vacuum volume, we conclude that the chamber is sufficiently clean to be added to the 40 Meter vacuum volume with no additional cleaning or baking required. 1 Introduction The vacuum system at the 40 Meter laboratory must maintain high vacuum in the interferometer volume, with minimal contamination from organic molecules which could stick to the surfaces of the optics and degrade the performance of the optical cavities. The vacuum system is described in [1]. In winter 2001 we will add an output optics chamber (OOC, built many years ago), an OOC seismic stack (newly built), and 12 meter mode cleaner tube and chamber (with seismic stack) to the vacuum envelope. It is important toeval- uate whether these elements are contaminated, so that they might degrade the overall vacuum pressure acheivable at the 40 meter, as well as the partial pressure of known contaminants. The tools we have to do this evaluation are: a variety of pumps (turbopumps and ion pumps) with a range of pumping speeds, cold-cathode gauges, and a residual gas analyzer (RGA) manufactured by Dycor. Atypical RGA scan is shown in Fig. 1. Peaks associated with N 2,O 2,CO 2,H 2 O, and H 2, and fragments thereof, are seen. They dominate the total pressure. The absolute value of the pressures in the RGA scan are not well calibrated (see below), either absolutely or relatively as a function of AMU. The partial pressures of the high-amu molecules are of concern. These are typically organic molecules formed from the breakdown of pump oil. They can stick to mirror surfaces and degrade their optical quality. Above AMU's of 100, the partial pressures are so small that the RGA is not very sensitive to them. However, the partial pressures of molecules with AMU of 41 and 43 (byproducts of pump oil) have been observed to roughly scale with the higher mass ones, and they are large enough to measure (you can see them in Fig. 1 in between the much higher peaks from Ar-40 and CO 2-44). Thus, we use these RGA measurements as a gauge of the vacuum quality at the 40 Meter, and they are carefully monitored. 2 Pumping speeds, partial pressures, outgassing rate Pump-down of the 40 Meter from the vented state proceeds in stages: ffl Roughing pumps clear out the small volumes between the pumps and the main volume. ffl Roughing pumps reduce the pressure in the main volume from 760 torr to 0.5 torr, over about 3 hours. Pressure is monitored using Pirani gauges from 760 torr to 10 4 torr, then using cold cathode gauges on down. 1

Figure 1: Atypical RGA scan at the 40 Meter (partial pressure in torr vs AMU), taken after 177 days of pumping, with the maglev turbopump ON and electron multiplier ON. ffl Turbopumps take over at around 0.5 torr, reducing the pressure to some equilibrium value over many days. We rely mainly on one maglev turbopump for the main 40m volume. ffl For vibration-free pumping, ion pumps are used (for pressures below 10 6 torr). There are 4 ion pumps distributed around the 40m volume (a fifth pumps on the annulus regions of the optics chambers). They have not been used for manyyears, because they get saturated during vents. We will install gate valves, and regenerate these ion pumps, in winter 2001. 3 Time dependence of pressure, outgassing, etc The ideal time-dependence of the pressure is described as follows: ffl The number of molecules at a particular AMU, in volume V,isN = pv=kt = nv, where n = molecular number density. ffl The pump pulls molecules out at a rate dn dt = N V dv dt = ns p where S p is the pump speed in ltr/s. the pump speed depends on the type of molecule (or AMU) and also on the pressure; it is approximately constant only over some range of pressures. ffl Molecules enter the volume through leaks, diffusion through O-rings, or outgassing from the walls, at a rate _N out, which is slowly-varying. Thus, dn dt = _ N out ns p ) dp dt = _ N out kt V S p V p: Light molecules like H 2 diffuse through the viton O-rings, while heavier organic molecules stick to, and outgas from, the walls. 2

ffl the solution to this differential equation (assuming constant S p )is p(t) =(p 0 p u )e Sp=V t + p u ; p u = _N out kt=s p where p 0 is the initial pressure (760 torr), and p u is the ultimate pressure (limited by outgassing). ffl The time to pump down from p 0 to p u, assuming p 0 fl p u, and assuming constant S p,is t down = V S p ln p0 p u : By measuring the exponential decay time constant V=S p between a range of pressures for which S p is roughly constant, and estimating V,we can determine S p, and compare with what the pump manufacturer claims. Typically, the measured number is smaller than the manufacturer's spec, because the pumps are typically mounted to the volume in a conductance-limited manner. ffl The outgassing rate can be written as _N out =(N W =A)Ar out, where N W =A is the number of molecules per unit area stuck to the walls, A is the area of the vacuum volume walls, and r out is the rate for one molecule to desorb from the walls. Both N W =A and r out depend strongly on the molecule in question, the material and preparation of the walls, etc, and both can be slowly varying in time. For the sticky organic molecules, r out is very small; 1=r out is weeks or months. ffl The number of molecules per unit area stuck to the walls, N W =A, slowly falls as we get down below one layer: dn W = r out N W + r rea n; dt where r rea is the re-adsorption rate (which is presumably small for small n, we will neglect it). So: N W = NW 0 e routt + readsorption: ffl In the end, the figure of merit for the cleanliness of a vacuum volume is given by the outgassing rate ρ out N W kt A r out in torr-ltr/s/cm 2. Typical outgassing rates are 10 7 for metals, 10 5 for silicone, or larger for really sticky gunk. The ultimate pressure (for constant ρ out )is p u = ρ out A=S p : ffl So, we can estimate A, measure S p from pump-down or from a calibration, and then determine ρ out from the observed p u. ffl Note that diffusion through o-rings at ports can also contribute to the outgassing" rate. 4 Estimate of 40 Meter vacuum volume and surface area Precise values for the dimensions of all components of the 40m vacuum envelope presumably exist; but we're not sure where to find them. Below, we make a reasonable estimate of the volume and surface area of the vacuum envelope. This does not include the contributions from the contents of the vacuum envelope (seismic stacks, optical tables, IFO equipment). This, of course, makes a significant uncertainty in the surface area; and, most likely, the outgassing rate per unit area is most likely dominated by these contents. Thus, all numerical conclusions drawn from these estimates should be taken with a generous margin of error. The full 40 meter volume consistes of: 3

ffl Two beam tubes, 4000 cm each, 24" diameter (61 cm). Volume = 11,690 ltr, area = 766,549 cm 2 (each). ffl Five BSC's, each 124 cm diameter, 155 cm high. Volume = 1872 ltr, area = 60,381 cm 2 (each). ffl One side chamber, 2'x2.5'x4.5' (61x76x137 cm). Volume = 637 ltr, area = 46,916 cm 2 (each). We will add a second (output optic) chamber, soon. ffl Total volume = 33,347 ltrs. ffl Total area = 1:9 10 6 cm 2 ffl Since we are ignoring the surface area of the contents of the 40 Meter vacuum, this is surely a (gross?) underestimate. 5 OOC Pumpdown The OOC is an empty volume with steel walls. It has five large doors (not shown), each with single baked viton o-ring seals (no annulus region), and ten 8" or smaller flanges with copper gaskets. It was pumped down on 7/31/00, and the pressure was monitored for 77 days, followed by a vent on 10/16/00. The configuration is shown in Fig. 2. A Welsh rotary pump rated at 650 l/s was used to rough out the volume to around 0.5 torr (it took about 14 minutes), a Balzer turbopump rated at 60 l/s brought the total pressure down to 10 5 torr in 75 minutes. During this time, the total pressure was monitored regularly using Pirani and then cold cathode gauges, and a Dycor RGA was used to monitor the partial pressure of various molecules, especially those with AMU of 41, 43, 53, 55, and 57, all of which are hydrocarbon fragments associated with pump oil breakdown and which are thought to be particularly dangerous to optical surfaces. The turbopump brought the total pressure down to 4 10 6 torr after twoweeks of pumping. At that point, a new ion pump rated at 400 l/s took over, quickly bringing the pressure to 1:4 10 7 torr. Over the next two months, the total pressure hovered around 9 10 8 torr. 8" ports with baked viton o-ring seals RGA OOC Pirani Gauge P N2 cal leak Welsh rotary roughing pump 650 l/s manual isolation valve exhaust Ion Pump 400 l/s CC Cold Cathode Ar cal leak Balzer Turbo 60 l/s Forepump Figure 2: Configuration for pump-down of the output optic chamber (OOC) from 7/31/00 through 10/16/00. 4

6 Calibration In order to establish the outgassing rate of the OOC (due to outgassing from the walls, diffusion through o-rings, or leaks), we need to know the pump speed and the partial pressures for the AMU's of concern (41, 43, 53, 55, 57) from the RGA. Both of these quantities require calibration. The Balzer turbopump was rated at 60 ltr/s, but it was connected to the chamber via a tube of diameter d =3:4 cm and length ` =10" = 25.4 cm, with an elbow. Thus, at low pressures (molecular flow), the effective pumping speed is limited by conductance. The conductance limited pumping speed is given by the formula [2] S pc =12:1 ltr/s d 3 =`, with d and ` measured in cm. Further, the elbow reduces this by a factor 0.3. So, effective pumping speed is roughly 12 ltr/s. The effective pumping speed was checked with a calibrated leak, as discussed below. 6.1 Nitrogen leak We have a calibrated leak source on the OOC, produced by Vacuum Technology Inc (VTI, Oak Ridge TN), part number C8-8-N2-2CFF-FV. It is N 2 at 7.4 psia. The leak rate is 1:0 10 8 torr-ltr/s at 24 ffi C. It degrades by 0:6% per year, and it is around 10 years old (built 10/91). Thus, the current leak rate is around LR =0:94 10 8 torr-ltr/s. We vented the leak into the chamber, then closed it. We left it for 26 hours, then vented it into the 625 ltr OOC. We expect a rapid rise in the partial pressure for N 2 of P 14 = LR t leak =V =0:94 10 8 (26 3600)=625 = 1:4 10 6 torr: On the RGA, we saw a sharp rise of P 14 =1:3 10 7 torr, followed by an exponential decay back to the baseline (Fig. 6.1). From the N 2 calibrated leak, it appears that the RGA appears to be off in absolute pressure calibration, by a factor of 10. The RGA had been calibrated while attached to the 40m main volume some time ago, and a factor of 10 mis-calibration seemed unlikely. As we will see below, an independent calibration of the RGA gives results in much better agreement with previous calibrations. We thus strongly suspect that the N 2 leak rate is wrong. Despite this, the pump speed can be reliably determined. After the initial sharp rise, the P 14 dropped back to its previous value with a time constant of fi 1=e 2 = 2V=S pc = 84 s, so S pc =14:9 ltr/s, compared to the expected 12 ltr/s. This is independent of the calibration of the calibrated leak and of the RGA. Figure 3: Response of RGA channel 14 (N 2 )tothe release of 26 hours of calibrated leak accumulation. 5

6.2 Argon leak We have a calibrated Argon leak source, produced by Vacuum Technology Inc (VTI, Oak Ridge TN), part number CL-8-AR-2CFF-FV. It is Ar at 15. psia. The leak rate is 5:3 10 8 torr-ltr/s at 24.3 ffi C. It degrades by 0:7% per year, and it is around 8 years old (built 10/1/92). Thus, the current leak rate is around LR =5:00 10 8 torr-ltr/s. For various reasons, the Ar calibrated leak was not installed on the OOC. We were able to use it once wevented the OOC (on 10/15/00), and re-plumbed the small turbo pump, calibrated leaks, and RGA head together (without the OOC). With the 14.9 ltr/s turbopump going, we turned the leak on for a while, then turned it off for a while, and repeated. We found that the RGA-reported pressure for AMU 28 (Argon) changed from p 28 =3:5 10 11 torr when closed to p 28 =1:3 10 9 torr when open. We would predict an open" pressure of p pred 28 = LR=S p =5:00 10 8 (torr-ltr/s) = 14.9 ltr/s = 3:3 10 9 torr. Thus, we conclude that the RGA readings for AMU 28 need to be multiplied by 3:3=1:3 =2:5 in order to be interpreted at true partial pressure in torr. There is much better agreement than was seen with the N 2 leak. For various reasons, we believe the Ar leak calibration and not the N 2 leak calibration. However, the determination of the pump speed S pc =14:9 ltr/s using the N 2 leak should be reliable, as it does not depend on the accuracy of the N 2 leak calibration. 7 Conclusions We use the nitrogen leak calibration to determine the pumping speed of the turbo-pump used to pump on the OOC. We use the argon leak calibration to determine the absolute scale of the RGA partial pressure readout, for argon. The absolute scale of the RGA partial pressure readout for AMU 41 will be different than for AMU 28, due to the mass rependence of the RGA response, which is (naively) expected to scale like p p AMU. Thus, an additional calibration factor of 41=28 must be applied. The partial pressure of AMU 41 acheived after 77 days of pumping on the OOC, was 2:7 10 11 torr at the turbo-pump speed of 14.9 ltr/s. Applying the two calibration corrections mentioned above gives p u (41) = 8:2 10 11 torr, or an outgassing rate of N_ 41 =1:2 10 9 torr-ltr/s. The outgassing rate per unit area is ρ 41 =1:2 10 9 torr-ltr/s=47; 000 cm 2 =2:6 10 14 torr-ltr/s/cm 2 : This should be compared with the total outgassing rate at the 40 Meter. The maglev turbopump (TP1) at the 40 Meter has a rated speed of 300 ltr/s. On 3/6/00, after 26 days of pumping, the corrected partial pressure of AMU 41 was p 41 =7:6 10 11 torr, corresponding to an outgassing rate of _N 41 =2:2 10 8 torr-ltr/s. The outgassing rate per unit area at the 40m is ρ 41 =1:1 10 14 torr-ltr/s/cm 2, somewhat lower than the OOC. This calculation was repeated using the sum of the partial pressures of AMU's 41, 43, 53, 55, and 57, instead of just AMU 41. The results were quite consistent. From these calculations, we see that the addition of the OOC will increase the total outgassing rate at the 40m by 5%. This is acceptable. We conclude that no additional cleaning or baking of the OOC is required before installation into the 40m vacuum. References [1] Upgrade of the 40m Vacuum System. LIGO note T000054-00-R. [2] Leybold catalog. 6