CB-50 Data Buoy Quick Start Guide

Similar documents
CB-40 Data Buoy Quick Start Guide

CB-150 Data Buoy Quick Start Guide

QUICK START GUIDE CB-150 DATA BUOY PLATFORM

QUICK START GUIDE CB-450 DATA BUOY PLATFORM

QUICK START GUIDE CB-950 DATA BUOY PLATFORM

ENVIRONMENTAL DATA BUOYS

Assembly Instructions. -Cantilever Boat Lifts

BUTTERFLY VALVES Series 800

HEAVY DUTY SIT-UP BENCH SF-BH6502 USER MANUAL

QUALITY ALUMINUM BOAT LIFTS, INC. INSTRUCTIONS. Dominator Lake Lift

CLIENT NAME: LOCATION: CALM BUOY INSPECTION:

Shoreline Cantilever Lift 2500lb Capacity Models: (108" inside width) - Part # (120" inside width) - Part #

Tripod Setup Guide (M-TPx)

Backboard and Rim Owners Manual

Operator s Safety Manual Sumner Max Jax / Beam Jax

Reliance Industries, LLC Operating instructions for the / Bolt-on D-Ring Anchorage. Model # 3071

MUELLER. A Wall Type. Indicator Post. Reliable Connections. General Information 2. Technical Data/ Dimensions 3. Installation 4-5.

Fully Submersible Heavy Lift Vessel

VL 2K LIFT D-L WINCH INSTRUCTIONS (Applies to P/Ns , , , , , )

Chapter 2 Rigging. Cutting Wire Rope. Anchoring Wire Rope to Drum. Winding Wire Rope Onto Drum

Tooling List 3/8 Ratchet 3/8-10mm Deep Socket 10mm Wrench 3mm Allen Wrench #2 Phillips Screwdriver Large Jaw Pliers Needle Nose Pliers

VERSA BIKE RACK INSTRUCTIONS

CHAPTER 4: BEST MANAGEMENT PRACTICES FOR EROSION AND SEDIMENTATION CONTROL

Thank you for purchasing a Porta-Dock product! *Please read and follow these instructions step by step*

2,500/4,000 LB Easy Riser Vertical Cable Feighner Lift

MUELLER A A Non-Adjustable. Vertical Indicator Posts. Reliable Connections. General Information 2. Technical Data 3.

Vertical Bladder Tanks

Fully Submersible Heavy Lift Vessel

#59114 Rola 2-Bike Rack Carrier (Shown Assembled) (A) (C) (B)

Installation Operation Maintenance. Bermad Level Control Valve with Modulating Horizontal Float Pilot valve One Way Flow IOM.

9408 Series Dissolved Oxygen Systems. Dissolved oxygen systems designed for reliable operation with minimal operating costs

Installation, Operation and Maintenance Instructions Buffer Vessel OM006

ABB MEASUREMENT & ANALYTICS DATA SHEET series Dissolved oxygen systems

FXT. FXT Cooling Tower RIGGING & ASSEMBLY INSTRUCTIONS

IMPORTANT: RECEIVING INSTRUCTIONS:

Installation, Operation and Maintenance Instructions for Direct Hot Water Storage Vessels

OPERATIONS/PARTS MANUAL FOR PATTERSON'S MODEL # WWP40M-LPS-6 LOW-PROFILE BARGE CONNECTOR WINCH

Model Copyright 2012 by General Machine Products (KT), LLC

Lectric Cycles Mid-Drive Electric Motor Installation

! WARNING. Model PFC-1-G (direct acting) PFC-1-GR (reverse acting) Modulating Pneumatic Liquid Level Controls INSTRUCTION MANUAL MM-110B

PRODUCT CARD WALL MOUNTED FIXED BASKETBALL CONSTRUCTION PROJECTION: FROM 1,00 TO 2,25 M

National Marine Manufacturers Association

Low Wind High Yields Series

Model MTB-ASME Vertical Bladder Tanks

Horizontal Bladder Tanks

DIP STATION WITH SAFETY CONNECTOR SF-BH6507 USER MANUAL

CAUTION - PUT SAFETY FIRST

Model MTB-ASME Vertical Bladder Tanks

VTL VFL VCL. Low Profile Series V RIGGING & ASSEMBLY INSTRUCTIONS

WORK TABLE CART OWNER S MANUAL

WW-720. Pressure Reducing Control Valve

PRODUCT CARD WALL MOUNTED SIDE FOLDED BASKETBALL CONSTRUCTION PROJECTION: FROM 1,2 TO 2,45 M

Universal Elevator Mount Owners Manual Customer Service Center N53 W24700 South Corporate Circle Sussex, WI U.S.A.

How to install AEA s 10 meter meteorological tower

PORTS OF DAMPIER & ASHBURTON MOORING DIVE INSPECTION STANDARDS AND DELIVERABLES TABLE OF CONTENTS

Instruction Manual Updated 7/26/2011 Ver. 2.2

AYLESBURY 'KB' TYPE FLOAT VALVES

Pioneer Array Micro-siting Public Input Process Frequently Asked Questions

Apollo Standard Port, Full Port & One Piece Flanged Ball Valves Installation, Operation, & Maintenance Manual

ATS430 turbidity sensor Retractable insertion assembly

OPERATION and MAINTENANCE Guide

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

Miniball Coulomb Excitation Target Chamber

KENNEDY VALVE OPERATION & MAINTENANCE MANUAL

75 Ton SD Shop Press Operating Instructions

User Instruction Manual For Davit Rescue System

Wellhead Mast. Installation and Operation Guide. Nanometrics Inc. Kanata, Ontario Canada

Installation Operating Instructions for Duplex Manual Manifolds PX-TMD Series

Personal Fall Arrest System. User s. Manual. Part Number January 2014 (Replaces July 2013)

WW-720. Pressure Reducing Control Valve

Procedure for Setting a Mooring

WATER QUALITY Buoy Profiling

Roller Chain and Sprocket Troubleshooting Guide

1. Product Name. 2. Product Code. 3. Colour. 4. Brief Description. 5. Contents. Itinerant Frame. Likely to be as shown

Model MTB-ASME Horizontal Bladder Tanks

OWNERS MANUAL. Foldable Topside Creeper Model ATD-8116F

OPERATIONS/PARTS MANUAL FOR PATTERSON'S WWP40M-12 and all WIDE DRUM variations of this HAND OPERATED WINCH.

Assembly, disassembly and user manual

NAVIGATOR PROP BUILDING INSTRUCTIONS & PHOTOS

Model 10E Enviro-Line Environmental Pressurization System Installation & Operation Manual

BRAKE WINCH RUP 503-[T/BT] EQUIPMENT FOR LIFTING LOADS. AT 053-[T/BT] xx

INSTALLATION COMMISSIONING, OPERATION & MAINTENANCE MANUAL

09/17/2007 Copy VISIT THE LIFETIME WEB SITE:

Reduce pressure zone device suitable for high and medium hazard rated applications Flanged end connections

ROTATING DISK VALVES INSTALLATION AND MAINTENANCE 1. SCOPE 3 2. INFORMATION ON USAGE 3 3. VALVE TYPES 3 4. OPERATORS 5 5. VALVE CONSTRUCTION 6

KTM OM-2 SPLIT BODY FLOATING BALL VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

DO NOT use any Alien Flier Zip Line Products or Accessories until you read and understand these SAFETY WARNINGS!

TTX-1 PORTABLE TRUCK ACCESS FALL PROTECTION PLATFORM

Vac Bagger Wheelhorse 42 and 48 Mowers for Classic Garden Tractors

Installation Operating Instructions for Simple Duplex Manual Manifolds PX-TSD Series

BC Shackle. Made in the China. Alloy Steel Anchor Shackle. Instructions for handling and use - Please read in full before using this device

Pac West Supply LLC Gorilla Guard Ladder Cage Enclosure Installation Guide

7130 Lancer Rear Drive Magnetic Commercial Indoor Cycling Bike

LAD-SAF LAD-SAF VERTICAL SAFETY SYSTEM THE ULTIMATE IN FALL PROTECTION

Technical Diving Equipment

310 SERIES TILT-TO-LOAD ROTATOR. The Specialist In Drum Handling Equipment

Constant Pressure Crude Oil Container Model CPCCP

HPIC D Hydrostatic Test Pump PRODUCT INFORMATION AND OPERATING INSTRUCTIONS

KRYPTON X ROAD : ASSEMBLY GUIDE

BELT DRIVE INDOOR CYCLING BIKE SF-B1712

Transcription:

CB-50 Data Buoy Quick Start Guide The NexSens CB-50 Data Buoy is designed for quick deployment in emergency response situations including industrial spills and natural disasters. The buoy can be deployed from small boats, large vessels or even helicopters. Compatible instruments include turbidity sensors, dissolved oxygen sensors, hydrocarbon sensors, fluorometers, multi-parameter sondes, pressure transducers, and more. What s Included: (1) Buoy hull with data logger port (3) Top-side lifting eyes (1) Sub-surface mooring eye

CB-50 Data Buoy Accessories The CB-50 Data Buoy is a platform and can be accessorized with any of the following components or users can configure the buoy with alternatives. Common Accessories SDL-V2 SDL V2 submersible data logger SDL-V2-C-VZ4G SDL V2 submersible data logger with Verizon 4G LTE cellular telemetry SDL-V2-C-AT4G SDL V2 submersible data logger with AT&T 4G LTE cellular telemetry M550-F-Y Solar marine light with flange mount & 1-3 nautical mile range, 15 flashes per minute, yellow CAGE Stainless steel instrument cage, 28" CAGE-EXO1 EXO1 sonde mooring cage with clamps CAGE-EXO2 EXO2/EXO3 sonde mooring cage with clamps CB-CCA Cage anti-rotation collar for CB-Series data buoys CM-600 Cage mount for water quality instruments CB-ZA Sacrificial zinc anode for CB-Series data buoys

CB-50 Step-by-Step Assembly Attach the cage to the buoy frame: 1 Attach the cage to buoy frame using the ¾ bolt, lock washer and castle nut. 2 Tighten firmly with 1-1/8 wrenches or large crescent wrenches. Be sure to flatten the lock washer and lineup the hole in the bolt with the notches in the castle nut. 3 Place the cotter pin through the hole in the bolt, and bend the long leg of the pin to prevent the nut from coming loose.

CB-50 Step-by-Step Assembly Understanding the data well A removable topside foam tower with lid protects the electronics, supports solar marine lights, and offers a convenient lifting point. An SDL-V2 can be installed in the center of the buoy hull.

SAFETY FIRST Warning: It highly recommended that buoys are installed by professionals with training in marine safety. Anchors, chains, heavy gear and boat clutter during deployment is unsafe. Care must be taken during deployment to maintain a clean and safe environment. Use of proper equipment (work boat, lifting rig, gloves, safety footwear, etc.) is essential to safely deploy any buoy system. Buoy systems are heavy and personnel can quickly become entangled with mooring lines and anchors. Safety and flotation gear should be worn at all times when working on or near the water. NEVER EVER work in unsafe conditions, without safety gear, proper equipment or use unsafe practices.

Installing sacrificial anodes Important: To avoid excessive corrosion on buoy frames and cages, use sacrificial anodes to isolate dissimilar metals in saltwater applications. Install the CB-Series Buoy Zinc Anode to both the cage and buoy frame. The anode will slowly corrode away. Inspect and replace as needed.

Understand ballast weight and stability Important: To prevent overturning and ensure stability, additional ballast weight may be needed. As configured at the factory, the center of gravity of the buoy is near the water surface. A single point mooring line and chain, connected to the eye at the bottom of the cage is typically enough weight to ensure stability. Any weight added above the water surface must be appropriately counterbalanced by additional ballast weight below the surface. Be sure to keep topside devices lightweight and positioned as low as possible on the tower and bottom side weight centrally located and deep (mounted to the cage eye). Before deployment, some experimentation may be required to properly balance the buoy. If needed, add ½ chain (~2.3lb/ft) or other weight to the bottom of the cage as shown.

The proper level of submersion for a moored CB-50 buoy equipped with an SDL-V2 is shown. Note: Excess ballast weight may result in the submersion of the SDL-V2 bulkhead and a subsequent decline in both remote communication performance and life of the data logger. Recommendation: Do not allow the upper float of the CB-50 to be submerged for extended periods of time. The SDL communication bulkhead should be oriented above the water line under normal deployment conditions. Maximum recommended deployment static water level

Single point mooring Single-point moorings are used in calm waters when monitoring sensors are attached to the instrument cage or housed in deployment pipes. The sensors are thus protected and less vulnerable to damage caused by subsurface debris, high currents, and entanglement from anchor lines. In a single-point configuration, a stainless steel mooring line connects the buoy directly to a bottom chain and anchor. At normal pool/stage, the mooring line should be taut, with most of the bottom chain resting on the seafloor. As the water level increases and the buoy rises, the bottom chain is lifted from the floor. Important: This section contains only general information on the available mooring options for CB-50 data buoys. To develop an effective mooring strategy, a variety of application-specific criteria (water level fluctuations, currents and wave action, debris loads, etc.) must be thoroughly reviewed prior to deployment. NexSens does not endorse any particular mooring strategy for any specific application.