AYLESBURY 'KB' TYPE FLOAT VALVES
|
|
- Juniper Casey
- 5 years ago
- Views:
Transcription
1 PRE-INSTALLATION CHECKS AYLESBURY Valves are unlike any other float operated valve, ballcock or ball valve. Please read these instructions and refer to attached drawings before installation. Installation of valves should be in accordance with The Water Supply (Water Fittings) Regulations 1999 and BS6700:1997 Para Keraflo Valves contain a pair of maintenance free ceramic discs. Do NOT attempt to dismantle the Valve - even if you are curious! Should the Valve ever become blocked with debris, ask Keraflo for a Service Bulletin. EVIDENCE OF DISASSEMBLY OR SIGNS OF MISUSE MAY INVALIDATE WARRANTY. OPERATING SPACE: CHAIN LENGTH: OVERFLOW/WARNING PIPES TURBULENT WATER: FLANGED TANKS: ROUND TANKS: Check for sufficient clearance - see dimension sheet Ki010* and Ki014* for working dimensions. Do not cut or shorten the Stainless Steel Chain - its weight is critical. Likewise do not add weight by lengthening. Check the position of the Overflow and Warning Pipe (where fitted). See drawing Ki010* for closing water level (TWL) range. Exceptionally turbulent waters, eg: cooling towers, should be avoided directly beneath the float. Calming measures such as baffle plates, still ponds etc. should be implemented. The design of the Aylesbury 'KB' Type valves, sizes ¾ (20), 1 (25), 1¼ (32) and 1½ (40)SF allow sufficient clearance between the Float and a 70mm internal flange/rib. Sizes 1½ (40)HF and 2 (50)SF, allow sufficient clearance between the Float and a 45mm internal flange/rib. The Valve Backnuts may be adjusted to enable fitting to tanks with larger flanges; provided a minimum of 20mm exists between the Float and tank wall throughout the arc of the float. Minimum tank diameters required: Valve ¾ 1 1¼ 1½ SF 1½ HF 2 SF Min tank diameter (m) 0.50m 0.50m 0.60m 0.60m 0.80m 0.80m SLOPING TANK WALL: PIPEWORK SUPPORT: The wall to which the Aylesbury Valve is to be attached must be vertical. If the wall around the fixing hole is sloped, tapered washers must be used. These are generally available from the tank supplier. Aylesbury Valves create virtually no tank wall stress. Additional pipework support is therefore unnecessary; provided the Code of Practice for the support of pipework in general is met. SERVICING VALVES: A servicing valve must be fitted as near as is reasonably practicable to the float operated valve. A servicing valve incorporating a particle strainer is highly recommended. PLEASE PLACE LABEL ON TANK LID ABOVE VALVE FOR FUTURE REFERENCE.
2 INSTALLATION INSTRUCTIONS Installation of valves should be in accordance with The Water Supply (Water Fittings) Regulations 1999 and BS6700:1997 Para WARNING! THE BUILT-IN SPIRIT LEVEL MUST BE USED TO ALIGN THIS VALVE. FAILURE TO FOLLOW THE PROCEDURE LISTED BELOW WILL PREVENT THE VALVE OPERATING CORRECTLY REFER TO DRAWINGS DURING INSTALLATION To avoid damage fit the Actuator Tube after installing the Valve in the tank. 1 Before fitting the Valve, flush the supply pipes to clear all debris. Tanks and pipes should be disinfected using the procedures in BS 6700:1997 Para Remove and retain the Double R Clip and Actuator Lever from the Valve Body. 3 Remove and discard the protective Cap from the Tail. Remove and retain one Backnut. Insert the Valve Tail through the hole in the tank wall, replace the Backnut with the flanged side against the tank wall. 4 Connect the supply pipe, via a servicing valve, then hand tighten Backnuts to suit. To prevent the Valve turning when tightening the pipe fitting, use either a wrench or a spanner on the Valve Tail where indicated in drawing Ki014*. DO NOT USE A WRENCH ON ANY OTHER PART OF THE VALVE. 5 Fit the Actuator Tube over the Spigot. The Hanger must be on the right as shown in drawing Ki010*. 6 Fit the Actuator Lever over the Spigot and push its Pin through the bracket on the Actuator Tube and into the hole in the Black Wheel behind. Place a finger or thumb through the loop in the Double R Clip, then push the Clip into the Groove in the Spigot until it clicks into place. 7 The Actuator Tube will be tilting down to the left (brass end lowest). NOTE: the chain is not connected at this stage. Rotate the Tail of the Valve with a wrench until the Spirit Level indicates ABSOLUTELY level. (The Actuator Tube is actually angled 26º from horizontal). Tighten Backnuts then check alignment again. The bubble must be precisely between the black lines. 8 Remove and discard the protective Cap from the Discharge Assembly. 9 Hang the chain on the Hanger. The length of this chain determines the opening water level - see "ADJUSTING OPENING WATER LEVEL (LWL)" below. 10 Position the Closing Float Assembly along the chain to the required closing water level. Hook the Float Adjusting Peg THROUGH the required loop in the chain - see "ADJUSTING CLOSING WATER LEVEL (TWL)" below. Refer to drawing Ki010* ADJUSTING OPENING WATER LEVEL (LWL) The Valve will open once the water level has dropped far enough to expose most of the Opening Buoy. When the Actuator Tube is held horizontal, the groove in the Opening Buoy indicates the exact opening water level. Adjust the length of the chain with the Hanger. Loop the excess chain into the Hanger as shown in drawing Ki014*. DO NOT CUT OR REMOVE ANY CHAIN, ITS WEIGHT IS CRITICAL. The standard length of chain enables a lowest open level of 2000mm. A longer chain (factory fit option only) is available upon request. P/KBINSTALL/04-08 Page 2 of 5 KBInstall
3 ADJUSTING CLOSING WATER LEVEL (TWL) When the Actuator Tube is held horizontal, the closing water level is indicated by the base of the Closing Float. Drawing Ki010* also shows the closing water level in relation to the Closing Float when the valve is in the closed position. The highest achievable closing water level is shown in drawing Ki010* (Dimension Jmin). This can be achieved by having no spare chain links between the Hanger and the Float Adjusting Peg. The lowest closing water level (Dimension Jmax) can be achieved by having the float touching the top of the Opening Buoy whilst using all of the available chain (last link on Hanger). Position the Float Assembly along the chain to the required closing water level. Hook the Float Adjusting Peg THROUGH the required loop in the Chain. Applications where the Top Water Level (TWL) can rise after the Valve has closed will cause the Chain to become slack. A cable tie/ratchet strap should be fitted over the Float Adjusting Peg in such a way as to prevent the chain from slipping off. Ensure the Chain cannot become entangled with tank tie bars etc. DELAYED ACTION (LEVEL DIFFERENTIAL) The delayed action (level differential) is the difference between opening and closing water levels. This is adjustable between Pmin (Float touching top of Opening Buoy) and Pmax (Float Adjusting Peg almost touching Hanger whilst using all of the available chain) on drawing Ki010*. TESTING Before leaving the installation, test the Valve operation a number of times ensuring the Valve moves freely from the open to the closed position and from the closed to the open position. Where a Valve has not been in operation for a period of time it is also recommended that the above procedure is carried out. Ki010* Ki014* ATTACHED DRAWINGS Aylesbury KB Type Dimensions Front View Aylesbury KB Type Dimensions Side View KERAFLO RESERVE THE RIGHT TO CHANGE SPECIFICATIONS, DESIGN AND MATERIALS WITHOUT PRIOR NOTICE. KBInstall
4 P/KBINSTALL/04-08 Page 4 of 5 KBInstall
5 P/KBINSTALL/04-08 Page 5 of 5 KBInstall
k valve 2 (50)HF 2½ (65)SF installation guide aylesbury For valve sizes (DN): tel fax
aylesbury k valve installation guide For valve sizes (DN): 2 (50)HF 2½ (65)SF 3 (80)RB IMPORTANT Please keep for future reference. PLEASE READ THESE INSTRUCTIONS CAREFULLY AND REFER TO ANY DIAGRAMS BEFORE
More informationKAX VALVE ¾ (20) 1 (25) 1¼ (32) 1½ (40)HF 2 (50)SF INSTALLATION GUIDE AYLESBURY FOR VALVE SIZES (DN):
AYLESBURY KAX VALVE INSTALLATION GUIDE FOR VALVE SIZES (DN): ¾ (20) 1 (25) 1¼ (32) 1½ (40)HF 2 (50)SF IMPORTANT PLEASE KEEP FOR FUTURE REFERENCE. PLEASE READ THESE INSTRUCTIONS CAREFULLY AND REFER TO ANY
More informationk valve ½ (15) ¾ (20) 1 (25) 1¼ (32) 1½ (40)HF 2 (50)SF installation guide aylesbury For valve sizes (DN):
aylesbury k valve installation guide For valve sizes (DN): ½ (15) ¾ (20) 1 (25) 1¼ (32) 1½ (40)HF 2 (50)SF IMPORTANT Please keep for future reference. PLEASE READ THESE INSTRUCTIONS CAREFULLY AND REFER
More informationDESIGN AND PRE - INSTALLATION INFORMATION
DESIGN AND PRE - INSTALLATION INFORMATION Installation of valves should be in accordance with The Water Supply (Water Fittings) Regulations 1999 and BS6700:1997 Para. 2.2.4 KP Type Valves offer a flexible
More informationCOLD WATER STORAGE CONTROL AYLESBURY TM FLOAT VALVE RANGE
COLD WATER STORAGE CONTROL AYLESBURY TM FLOAT VALVE RANGE Keraflo have manufactured top quality, delayed action float valves in the UK for over 30 years. The Aylesbury TM range is synonymous with float
More informationCOLD WATER STORAGE CONTROL AYLESBURY DELAYED ACTION FLOAT-ACTIVATED VALVES
COLD WATER STORAGE CONTROL AYLESBURY TM DELAYED ACTION FLOAT-ACTIVATED VALVES Keraflo have manufactured top quality, delayed action float valves in the UK for over 30 years. The Aylesbury TM range is synonymous
More informationImportant Note: Tighten lock nuts so the support tubes still swing freely see figure 2. There must be 1 2 threads of bolt past end of lock nuts.
Kit Contents: DESCRIPTION QTY. DESCRIPTION QTY. 2 Shank Assembly 1 Support Tube Assembly 1 Side Tube - Short 2 1-1/4 Shank 1 Center Tube - Long 1 3/8-16 x 2.0 Carriage Bolt 2 5/16-18 x 2.25 Carriage Bolt
More informationIMPORTANT: RECEIVING INSTRUCTIONS:
Instruction Sheet Sidewinder Mechanical Bender IMPORTANT: RECEIVING INSTRUCTIONS: Visually inspect all components for shipping damage. If any shipping damage is found, notify carrier at once.shipping damage
More informationChapter 2 Rigging. Cutting Wire Rope. Anchoring Wire Rope to Drum. Winding Wire Rope Onto Drum
Chapter 2 Rigging Cutting Wire Rope The wire rope must be tightly seized on both sides of the point where the wire rope will be cut, as shown in Figure 2-1. Seize the wire rope with either seizing wire
More informationKECKLEY INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS TYPE NO. 7 FLOAT VALVE
INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS TYPE NO. 7 FLOAT VALVE APPLICATION/SERVICE: The NO. 7 internally piloted valves are recommended where tight closing is essential. The NO. 7 is most
More informationVERSA BIKE RACK INSTRUCTIONS
VERSA BIKE RACK INSTRUCTIONS Models #8, 8 Important This rack is designed for use with a or. receiver hitch. The rack is designed to hold a maximum of two bicycles. Do not use it for anything other than
More informationRada-Presto TF2020 and TF2020S
Rada-Presto TF2020 and TF2020S PRODUCT MANUAL IMPORTANT Installer: This Manual is the property of the customer and must be retained with the product for maintenance and operational purposes. 1 INDEX Page
More informationHoldUp Plus2. Safety Kit included: See additional instructions for installation. REAR WHEEL TRAY. BASE (1x) lock WASHER (1x) KEY (2x) SAFETY CLIP (1x)
HoldUp Plus2 InsTAll This product on 2" hitch version of the HoldUp Front WHEEL TRAY assembly (1x) REAR WHEEL TRAY assembly (1x) wrench (1x) BASE (1x) bolt (8X) Lock WASHER (8X) Washer (8x) KEY (2x) SAFETY
More informationInstallation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units
Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units Models: EPS Single Pump EPT Twin Pump EPS-HP EPT-HP Single Pump High Pressure Twin Pump High Pressure
More informationATS430 turbidity sensor Retractable insertion assembly
A MEASUREMENT & ANALYTICS INSTRUCTION ATS430 turbidity sensor Retractable insertion assembly Measurement made easy 1 Introduction This publication details installation procedures for the retractable insertion
More informationTHE HF-300 SERIES. Operating and Service Manual. Series includes all variants of HF-300/301
THE HF-300 SERIES Operating and Service Manual Series includes all variants of HF-300/301 Issue A July 2015 1 TABLE OF CONTENTS 1. Description... 3 2. Installation... 3 3. Operation... 4 3.1. Spring Loaded...
More informationMini Glider Manual. Your Glider comes partially assembled. The front wheel and the handlebars require assembly.
Mini Glider Manual Congratulations on your purchase of the Mini Glider! Your glider is designed for years of nearly carefree use by your child. These instructions include how to set up your glider and
More informationProduct Manual B-Safety ClassicLine & PremiumLine Emergency Eyewash and Eye/Face Wash Equipment
Product Manual B-Safety ClassicLine & PremiumLine Emergency Eyewash and Eye/Face Wash Equipment 1. Application Emergency eyewash and eye/face wash equipment are prescribed first aid installations for workplaces
More informationEZee Glider Manual. Tools needed for Assembly: Wrench (included) Philips Screwdriver (not included) Assembly Instructions
EZee Glider Manual Congratulations on your purchase of the EZee Glider! Your glider is designed for years of nearly carefree use by your child. These instructions include how to set up your glider and
More informationENERGY BLADE 3K4. Energy Blade Installation Instructions
ENERGY BLADE 3K4 Energy Blade Installation Instructions 1 Contents General information 2 Scope of these instructions 2 Product information 2 Designated use 3 Warranty 3 Safety instructions 4 Assembly and
More informationVegas Easyfit Kitchen Sink Mixer
Vegas Easyfit Kitchen Sink Mixer Installation Instructions & User Guide Please keep these instructions for future reference Contents Thank you for choosing Bristan, the UK s leading taps and showers expert.
More informationWFO-*P Series Floor Diffuser - Plenum installation and maintenance instructions
WFO-*P Series Floor Diffuser - Plenum installation and maintenance instructions Author: Tony Pepper Creation Date: 6.11.09 Checked: MP, SF, WTK,NB Revision: 0 Tools required: 1 x Medium Size Flat Blade
More informationAREA VALVE SERVICE UNITS
AREA VALVE SERVICE UNITS. Unit 8, McKenzie Industrial Park, Tel No.: 44 (0) 161 428 7200 Bird Hall Lane, Fax No.: 44 (0) 161 428 7010 Stockport, Email: info@p3-phoenix.com U.K., SK3 0SB www.p3-phoenix.com
More informationPFC Lightweight Composite Push Up Mast. Operating Manual
PFC Lightweight Composite Push Up Mast Operating Manual South Midlands Communications Ltd SM House, School Close Chandlers Ford Industrial Estate Eastleigh, Hampshire SO53 4BY United Kingdom Tel: +44 (0)23
More informationBASIN AND WALL MIXER INSTALLATION INSTRUCTIONS
BASIN AND WALL MIXER INSTALLATION INSTRUCTIONS IMPORTANT INFORMATION IMPORTANT All tapware and showers to be installed by a licensed plumber and to Australian Standards. Fit tempering and pressure reduction
More information3. Align ratchet drive with female insert on assembly, and raise ratchet handle until the ratchet drive is firmly seated into the assembly.
Remote Bung Cap Removal Tool Assembly Instructions 1. Pull collar down on ratchet to fully extend. 2. Insert ratchet head and neck under spring. 3. Align ratchet drive with female insert on assembly, and
More informationHalsey Taylor Owners Manual STOP!
Halsey Taylor Owners Manual 4710 Freeze Resistant Floor Mounted Steel Fountain STOP! PLEASE READ THE FOLLOWING INFORMATION. ITALLATION ITRUCTIO FOR THE 4710FR FTN. WITH 97243C SINGLE VALVE CONTROL ASSEMBLY
More informationHalsey Taylor Owners Manual 4410 Freeze Resistant Tubular Fountain STOP!
Halsey Taylor Owners Manual 4410 Freeze Resistant Tubular Fountain STOP! PLEASE READ THE FOLLOWING INFORMATION. ITALLATION ITRUCTIO FOR THE 4410FR FTN. WITH 97243C SINGLE VALVE CONTROL ASSEMBLY ARE LOCATED
More information8MAY15 US RACK, Inc Falcon Drive, Madera, CA
8MAY15 US RACK, Inc. - 2850 Falcon Drive, Madera, CA 93637-559-661-3050 INSTRUCTIONS for Bedrail-mounted MOTORCYCLE RACK, Model 2001-4TRA WARNING: Do NOT attempt to install or use this rack without following
More informationInstruction Manual for ZY-021 Height adjustable Acrylic Backboard with Chain net
Instruction Manual for ZY-021 Height adjustable Acrylic Backboard with Chain net WARNING: IMPROPER INSTALLATION OR SWINGING ON THE RING MAY CAUSE SERIOUS INJURY OR DEATH Notice to assemblers: All basketball
More informationRS Important Notes. Contact. Bicycle Maintenance Stand instructions manual. Warranty Period : 1 year (from the date of your purchase)
Warranty Period : 1 year (from the date of your purchase) RS-1700 Bicycle Maintenance Stand instructions manual (ver.1.2 2016/12) For more details, read the attached "Minoura Limited Warranty Policy" card.
More informationInstallation Guide Wall Mounted Angled Flagpole
Installation Guide 1.5m - 4m Angled Flagpole Dimensions Flagpole Dimensions Wall Bracket Dimensions 2m Aluminium 76mm Glassfibre 114.3mm angle from vertical 2000mm 250mm 300mm 1715mm Backplate thickness
More informationShifting Lever. Dealer's Manual. RAPIDFIRE Plus SL-M2000 SL-M3010 SL-M4010. Thumb Shifter SL-TZ500. ROAD MTB Trekking. City Touring/ Comfort Bike
(English) DM-MDSL001-01 Dealer's Manual ROAD MTB Trekking City Touring/ Comfort Bike URBAN SPORT E-BIKE Shifting Lever RAPIDFIRE Plus SL-M2000 SL-M3010 SL-M4010 Thumb Shifter SL-TZ500 CONTENTS IMPORTANT
More informationDelVal Flow Controls Private limited
DelVal Flow Controls Private limited (A DIVISION OF DelTech CONTROLS LLC, USA) DelVal Series 50/5, 5A/5B Butterfly Valves INSTALLATION, OPERATION AND MAINTENANCE MANUAL ENGINEERING DATA SHEET E.D.S. NO
More informationINFLATOR TDUX-IT-16 AND GAS CYLINDER E
INFLATOR TDUX-IT-16 AND GAS CYLINDER E7512-0160 Operating manual Inflator TDUX-IT-16 together with the special gas cylinder E7512-0160 is specifically designed for inflating TDUX duct seals. The inflator
More informationOPERATION MANUAL Please read this Operation Manual carefully before use, and file for future reference.
English Lubrication Free Air Turbine Handpiece with Water Spray OPERATION MANUAL Please read this Operation Manual carefully before use, and file for future reference. OM-T0286E 001 Thank you for purchasing
More informationOWNER S GUIDE DUAL CONTROL THERMOSTATIC SHOWER VALVE. Shower Control. may differ depending on choice of Model. Concealing Plate. Handles and ISSUE 01
DUAL CONTROL THERMOSTATIC SHOWER VALVE Shower Control Handles and Concealing Plate may differ depending on choice of Model OWNER S GUIDE ISSUE 01 These instructions cover all exposed or concealed versions
More informationMAINTENANCE PROCEDURE FOR X 650
MAINTENANCE PROCEDURE FOR X 650 X 650 25. juli 2005-1/6 MAINTENANCE PROCEDURE FOR X 650 2 ND STAGE WARNING: This maintenance procedure is only for appointed Scubapro technicians that completed a course
More informationDrawn up by: / RK Revision: 01 Reviewed: Page: 1 of 23 HI-SR 540 USA. Operating instruction SR 540 Face Shield
Page: 1 of 23 Operating instruction SR 540 Face Shield Page: 2 of 23 General information The SR 540 Face Shield can be used together with the SR 500 Powered Air-Purifying Respirator system of components
More informationEcomow Electric Mower
Ecomow Electric Mower 1100 Watt Operation Manual 2 Year Replacement Warranty ECO-320 - Type 1 0509 To view the entire range visit: www.ozito.com.au SPECIFICATIONS - MODEL NO. ECO-320 Motor Size: 1100W
More informationCRP INSTALLATION, OPERATING AND MAINTENANCE INFORMATION FOR INLINE SAMPLING VALVES
CRP INSTALLATION, OPERATING AND MAINTENANCE INFORMATION FOR INLINE SAMPLING VALVES Sampling Valves Installation Commissioning and Operating Instructions SD IL 300 & SD IL 400 Inline Sampling Valve This
More informationParts List. 7. Handlebars 8. Grips 9. Handlebar Stem 10. Front Brake 11. Front Wheel 12. Crank 13. Chain
Woodworm Cruise Parts List 1. Free Wheel with Rear Hub 2. Fenders 3. Fender Stay 4. Quick Release 5. Saddle 6. Seat Post 7. Handlebars 8. Grips 9. Handlebar Stem 10. Front Brake 11. Front Wheel 12. Crank
More informationSEQUENTIAL SHOWER VALVE INSTRUCTION MANUAL PLEASE LEAVE THIS MANUAL WITH THE END USER
SEQUENTIAL SHOWER VALVE INSTRUCTION MANUAL PLEASE LEAVE THIS MANUAL WITH THE END USER CONTENTS 1. INTRODUCTION & SAFETY 1 2. DIMENSIONS 2 3. TECHNICAL DATA 3 4. OPERATION 4 5. COMPONENTS 5 6. SITE INSTALLATION
More informationInstallation, Operation and Maintenance Manual for Back Pressure Regulator
Installation, Operation and Maintenance Manual for Back Pressure Regulator Model 8860 2009 Groth Corporation IOM-8860 Rev. B 12541 Ref. ID: 95565 Page 2 of 13 Table of Contents I. INTRODUCTION 3 II. DESIGN
More informationDM-MARD (English) Dealer's Manual. ROAD MTB Trekking. City Touring/ Comfort Bike REAR DERAILLEUR XTR RD-M9100 RD-M9120
(English) DM-MARD001-00 Dealer's Manual ROAD MTB Trekking City Touring/ Comfort Bike URBAN SPORT E-BIKE REAR DERAILLEUR XTR RD-M9100 RD-M9120 CONTENTS CONTENTS...2 IMPORTANT NOTICE...3 TO ENSURE SAFETY...4
More informationLITERIDER 2&3 IMPORTANT WARNING. 2Bike (1x) Bolt (1x) Nut (1x) Small Hex Wrench (1x)
LITERIDER 2&3 3 Bike (1x) Bolt (1x) Flat Washer (2x) Nut (1x) Large Hex Wrench (1x) 2Bike (1x) wrench (1x) Small Hex Wrench (1x) keys (2x) Long Strap (1x) 2-Zip Strips (6x) 3-Zip Strips (9x) Wheel strap
More informationBoat Boat Loader Fitting Instructions
Aerodynamic & Heavy Duty Roof Rack Systems Australian Made - Australian Owned www.rhinorack.com Boat Boat Loader Fitting Instructions CONTROLLED Balance point 3 Front eye nuts position 3 Transom eye nut
More informationMini Mr.Bulletfeeder by Double-Alpha
Mini Mr.Bulletfeeder by Double-Alpha User Manual Thank you for choosing the Mini Mr.Bulletfeeder by Double-Alpha! This newly designed product will give you years of reliable service. It will make your
More informationCRP Ltd INSTALLATION, OPERATING AND MAINTENANCE INFORMATION FOR INLINE SYRINGE SAMPLING SYSTEMS
INSTALLATION, OPERATING AND MAINTENANCE INFORMATION FOR INLINE SYRINGE SAMPLING SYSTEMS Sampling Valves Installation, Operating & Maintenance Instructions SD IL 500 & SD IL 600 Inline sampling Valves This
More informationSTYLE 3414/3416 & 3421/3423 Apollo Monitor with Foldaway Legs OPERATING & MAINTENANCE INSTRUCTIONS
STYLE 3414/3416 & 3421/3423 Apollo Monitor with Foldaway Legs OPERATING & MAINTENANCE INSTRUCTIONS The Akron Style 3414/3416 & 3421/3423 Apollo Monitor is designed to provide efficient trouble-free operation
More informationModel 23H Hand Crank Seamer
OPERATOR'S MANUAL Model 23H Hand Crank Seamer If you are not experienced with your seamer, please read and understand this manual before operating the machine. If you have a question discuss it with your
More informationPressure Independent Control Series
Document No. 155-522 Pressure Independent Control Series Two-Way Cast Iron Flanged Bodies, ANSI 125 and 250 Description Siemens Pressure Independent Control Valves integrate three functions into a single
More informationFLANGED TWO-PIECE BALL VALVES
INTRODUCTION This instruction manual includes installation, operation, and maintenance information for FNW flanged split-body ball valves. This manual addresses lever operated ball valves only. Please
More informationLIQUIP DRYBREAK COUPLER. API800 Series MAINTENANCE INSTRUCTIONS
LIQUIP DRYBREAK COUPLER API800 Series MAINTENANCE INSTRUCTIONS API LOADING COUPLER TO API RP1004 June 2015 Issue: F M:\Product-Info\API8xx\6-Service-Maintenance\API800 MAINTENANCE INSTRUCTIONS 40183.doc
More informationCantilever Brake. Dealer's Manual. ROAD MTB Trekking. City Touring/ Comfort Bike
(English) DM-RCBR001-00 Dealer's Manual ROAD MTB Trekking City Touring/ Comfort Bike URBAN SPORT E-BIKE Cantilever Brake BR-CX70 BR-CX50 BL-4700 BL-4600 BL-R780 BL-R3000 ST-7900 ST-6700 ST-5700 ST-4600
More informationParts: Included in the parts box: Inner Rear Tire Tray. Inner Front Tire Tray. Trail Doc Clamp. Pivot Assembly. Trail Doc Post.
NV 2.0 2 Parts: Outer Front Tire Tray Inner Front Tire Tray Outer Rear Tire Tray Inner Rear Tire Tray Pivot Assembly Trail Doc Clamp Trail Doc Post Included in the parts box: 6mm Allen Wrench M6 Lock Washer
More informationCalCheck. Instrument User Manual V1.8
CalCheck Instrument User Manual V1.8 Unrivalled Part number: 21518 Detection. Part number: 21518 Declaration of conformity Manufacturer:, The Way, Fowlmere, Cambridge, England. SG8 7UJ Product: CalCheck
More informationType S301 & S302 Gas Regulators INTRODUCTION INSTALLATION. Scope of Manual. Description. Specifications. Type S301 and S302. Instruction Manual
Fisher Controls Instruction Manual Type S301 & S302 Gas Regulators October 1981 Form 5180 WARNING Fisher regulators must be installed, operated, and maintained in accordance with federal, state, and local
More informationKBV21i and KBV40i Key Operated Boiler Blowdown Valves Installation and Maintenance Instructions
4059051/3 IM-P405-48 EMM Issue 3 KBV21i and KBV40i Key Operated Boiler Blowdown Valves Installation and Maintenance Instructions 1. Safety information 2. General product information 3. Installation 4.
More informationWater Weir Flow Controller. Introduction. Safety Precautions. Mounting the Hardware
57007-88 Introduction Safety Precautions This instruction sheet describes how to set up and use the Hach (Figure 1). A water weir is a device that raises or diverts water to regulate the flow. Hach s water
More informationInstallation Instructions for the AlphaDeck Staging System
Installation Instructions for the AlphaDeck Staging System Step 1 - Preparation A. Before setting up this system, determine the location of the stages and all the parts you will need. B. Read through the
More informationCOMPACT TRIPLE WALL OUTLET STATION MODEL INSTALLATION AND OPERATING INSTRUCTIONS
COMPACT TRIPLE WALL OUTLET STATION MODEL 6255-1 INSTALLATION AND OPERATING INSTRUCTIONS To assure safe operation and conformation to local fire codes, all Porter Outlet Stations are designed to be used
More informationKBV21i and KBV40i Air Actuated Boiler Blowdown Valves
4059051/1 IM-P405-48 AB Issue 1 KBV21i and KBV40i Air Actuated Boiler Blowdown Valves Installation and Maintenance Instructions 1. Safety information 2. General product information 3. Installation 4. Commissioning
More informationReplacing the Reverse Osmosis ( RO ) Membranes
Replacing the Reverse Osmosis ( RO ) Membranes Changing your membranes is a relatively straightforward procedure that can be achieved by carefully following these instructions. During disassembly, water
More informationThumb Shifter Plus Thumb Shifter
(English) DM-SL0004-01 Dealer's Manual Thumb Shifter Plus Thumb Shifter Thumb Shifter Plus SL-FT55 SL-TX50 SL-TX30 Thumb Shifter SL-TZ20 IMPORTANT NOTICE This dealer's manual is intended primarily for
More informationThank you for purchasing a WIKE BOX BIKE!
Thank you for purchasing a WIKE BOX BIKE! Contents Safety.....3 Front wheel.4 Kickstand..5 Handle Bar & Box 6 Seat post and Saddle 7 Final pre-ride check 8 Tools needed to assemble Bike: -High table or
More informationLIQUIP DRYBREAK COUPLER. LYNX Series MAINTENANCE INSTRUCTIONS
LIQUIP DRYBREAK COUPLER LYNX Series MAINTENANCE INSTRUCTIONS API LOADING COUPLER TO API RP1004 February 2016 Issue: DRAFT A Issue: DRAFT - A 02/01/16 Page 1 CONTENTS LYNX Series Datasheet... 3 LYNX Series
More informationSpecification Catalogue
Uniclass SS_55_15_65 CI/SfB (53) Xh Specification Catalogue Contents Keraflo Overview 3 Our Products / Specification Support 4 Keraflo was founded in Aylesbury, Buckinghamshire in 1983. The town gave Keraflo
More informationInstallation, Operating, Inspection and Maintenance Instructions Ladder Climber s Safety System. Warning
OWNER'S MANUAL Installation, Operating, Inspection and Maintenance Instructions Ladder Climber s Safety System Model # s: 6000, 6001, 6010 Warning You must read and fully understand all instructions, or
More informationInstallation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units Digital Range
Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units Digital Range Models: DS 126 Single Pump / Single System DT 126 Twin Pump / Single System DS 160
More informationINSTALLATION, OPERATION AND MAINTENANCE GUIDE
INSTALLATION, OPERATION AND Placement in Pipeline System When installing Process Development & Control s ElastoTITE Elastomer-Hinged Check Valves in a pipeline, a minimum of five pipe diameters should
More informationDIRECT DRIVE DIXIE DOUBLE SEAMER Model 25D
OPERATOR'S MANUAL DIRECT DRIVE DIXIE DOUBLE SEAMER Model 25D LUBRICATE DAILY: A. Gears inside gear housing at chuck shaft (1) Oil B. Seam rolls and cam rolls (4) - Oil C. Seam roll levers through gear
More informationSTART UP MANUAL MADE IN USA REV US and Foreign patents and patents pending see
START UP MANUAL MADE IN USA 004-027-8896-00 REV 033116 295 East Corporate Place Suite 100 Chandler, AZ 85225 Toll Free: 1.800.621.5886 Phone: 480.893.7607 Fax: 480.753.3397 Paramount@1Paramount.com www.1paramount.com
More informationPure-Flo Handwheel Operated Valves (903, 913, 963) Instruction Manual
PFMM-08 Pure-Flo Handwheel Operated Valves (903, 913, 963) Instruction Manual This manual provides installation, operation and maintenance instructions for Pure-Flo Diaphragm Valves (with 903, 913, 963
More informationInstallation Operation Maintenance. Bermad Level Control Valve with Modulating Horizontal Float Pilot valve One Way Flow IOM.
Bermad Level Control Valve with Modulating Horizontal Float Pilot valve One Way Flow Model: FP 450-80 Installation Operation Maintenance PAGE 1 OF 5 1. Safety First BERMAD believes that the safety of personnel
More informationDM-RD (English) Dealer s Manual. ROAD Rear Derailleur RD-9000 RD-6800 RD-5800 RD-4700
(English) DM-RD0003-09 ROAD Rear Derailleur Dealer s Manual RD-9000 RD-6800 RD-5800 RD-4700 CONTENTS IMPORTANT NOTICE...3 TO ENSURE SAFETY...4 LIST OF TOOLS TO BE USED...6 INSTALLATION...8 Chain length...
More information4 ANGLE GRINDER MODEL NO: CAT 52 PART
4 ANGLE GRINDER 4 ANGLE GRINDER MODEL NO: CAT 52 PART No: 3110685 OPERATION & MAINTENANCE INSTRUCTIONS 0807 Fig.1 SPECIFICATIONS Model:...CAG52 Part Number:...3110685 Rated Wheel...Capacity: 4 x 1/4 (type
More information600 / 600FC OWNER'S MANUAL
PROGRESSION 600 / 600FC OWNER'S MANUAL Issue 2 / Version E - Dec. 10, 1997 Copyright 1997 GAMMA Sports - All Rights Reserved PROGRESSION 600 / 600FC OWNER'S MANUAL TABLE OF CONTENTS PAGE 1... WARRANTY
More information7130 Lancer Rear Drive Magnetic Commercial Indoor Cycling Bike
7130 Lancer Rear Drive Magnetic Commercial Indoor Cycling Bike Owner s Manual Made in Taiwan INDEX IMPORTANT SAFETY INFORMATION... 1 EXPLODED DRAWING... 2 PARTS LIST... 3 ASSEMBLY INSTRUCTION... 4-9 USER
More informationDri-Line Mk2 Spirax-Monnier Compressed Air Drain Trap
0509950/2 IM-P050-21 CH Issue 2 Dri-Line Mk2 Spirax-Monnier Compressed Air Drain Trap Installation and Maintenance Instructions 1. Safety information 2. General product information 3. Installation and
More informationInstallation, Operating and Maintenance Instructions. V914 Cast Iron Flanged Swing Check Valve V914
Installation, Operating and Maintenance Instructions V914 Cast Iron Flanged Swing Check Valve V914 THE PRESSURE EQUIPMENT DIRECTIVE 97/23/EC and CE MARKING The Pressure Equipment Regulations 1999 (SI 1999/2001)
More informationHow to ensure optimal functionality of Campagnolo drivetrains
How to ensure optimal functionality of ampagnolo drivetrains A.1 - POWER-TORQUE SYSTEM The bearing seat must be fit without interference on the RIGHT side, and the bolt should be inserted in the LEFT cup
More informationPaintball Marker. User s Manual. 530 South Springbrook Road Newberg, OR 97132
Paintball Marker User s Manual 530 South Springbrook Road Newberg, OR 97132 Component Concepts, Inc., 530 South Springbrook Road, Newberg, OR 97132 Phone: (503) 554-8095 Fax: (503) 554-9370 www.phantomonline.com
More informationSanta Fe Cycles Assembly Guide Introduction
Santa Fe Cycles Assembly Guide Introduction Congratulations on your purchase of your new Santa Fe bicycle. You have purchased a bicycle that has many features and qualities. Please take a few minutes and
More informationEngineering Data Sheet
Page 1 of 6 CE MARKING AND THE PRESSURE EQUIPMENT DIRECTIVE 97/23/EC Valves must be installed into a well designed system and it is recommended that the system be inspected in accordance with the appropriate
More informationModel GPR Primary Pressure Regulating Valve. Instruction Manual
Model GPR-2000 Primary Pressure Regulating Valve Instruction Manual Please read this instruction manual thoroughly before using the primary pressure regulating valve, so that you may do so correctly and
More informationsafety Shut-Off Valve HON 721
safety Shut-Off Valve HON 7 product information serving the gas industry worldwide safety shut-off valve HON 7 safety shut-off valve HON 7 Application, Characteristics, Technical Data Application safety
More informationPENBERTHY SUBMERSIBLE AUTOMATIC SUMP DRAINER INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS
Before installation, these instructions must be read carefully and understood. PRODUCT WARRANTY Emerson warrants its Penberthy products as designed and manufactured to be free of defects in the material
More information602 STRINGING MACHINE OWNER'S MANUAL
PROGRESSION 602 STRINGING MACHINE OWNER'S MANUAL AL Issue 1- April 2000 Copyright 2000 GAMMA Sports - All Rights Reserved PROGRESSION 602 STRINGING MACHINE TABLE OF CONTENTS PAGE 1... WARRANTY PAGE 2...
More informationINSTALLING THE TRIDENT 11, 13 OR 15 RUDDER
INSTALLING THE TRIDENT 11, 13 OR 15 RUDDER Parts Included: Steering Parts: Foot Rail Parts: Rudder Parts: Retraction Parts: 4 - Rubber 2 - Rail Assemblies 1 - Rudder Body 1 - Rudder Retraction Grommets
More informationAssembly Instructions. -Cantilever Boat Lifts
Assembly Instructions -Cantilever Boat Lifts Winch Instruction Page Safety Information 1. The winch is built for the multipurpose of hauling and lifting operations. It is not to be used as a hoist for
More informationInstallation and Training Manual
AirForce1 Tower Kit Installation and Training Manual FuturEnergy Limited Ettington Park Business Centre Stratford upon Avon CV37 8BT +44 (0)1789 451070 Table of Contents Safety Notes... 3 Parts Supplied
More informationINSTALLATION GUIDELINES
STYLE No. UNWD11 Universal Traditional One Hole Instant Hot Water Dispenser with Metal Lever Handle STYLE No. UNWD31 Universal Industrial One Hole Instant Hot Water Dispenser with Metal Lever Handle STYLE
More informationCRYOGENIC TANK SERVICES - CHART RECORDER MANUAL
CRYOGENIC TANK SERVICES - CHART RECORDER MANUAL Pressure Chart Recorder / Temperature Chart Recorder / Dual Recorder Portable Mechanical Chart Recorder for the accurate measurement and recording of Pressure
More informationBGC258 Series BASOTROL Gas Valve
Installation Instructions BGC258 Issue Date September 6, 2017 BGC258 Series BASOTROL Gas Valve Installation IMPORTANT: These instructions are intended as a guide for qualified personnel installing or servicing
More informationStandard. Standard. Venepuncture Arm. Light. Part No: Brown. Part No: Black. Part No: 00332
Setup Guide Standard Standard Light. Part No: 000 Brown. Part No: 00 Black. Part No: 00 Part No: 065-964 Issue, June 0 0 Limbs & Things For more skills training products visit limbsandthings.com Limbs
More information1.0 - OPENING AND CLOSING THE DOOR
The purpose of this manual is to provide the user with instructions on how to safely open and close, how to conduct routine maintenance, and how to install the PEI TWINLOCK Closure on a pressure vessel.
More informationINSTALLATION, OPERATING & MAINTENANCE MANUAL WATER DRAIN VALVE
INSTALLATION, OPERATING & MAINTENANCE MANUAL WATER DRAIN VALVE Contents 1 Introduction 1. Introduction... 3 2. Specification... 4 3. Installation... 7 4. Operation...11 5. Maintenance...14 This Water Drain
More informationGENUINE PARTS INSTALLATION INSTRUCTIONS
GENUINE PARTS INSTALLATION INSTRUCTIONS DESCRIPTION: APPLICATION: PART NUMBER: Weight Distributing Hitch Ball Mount Class IV See dealer application charts 999T7 WQ820 TOOLS REQUIRED: 14 mm Wrench or Ratchet
More informationManual Actuated Boiler Blowdown Valves
Manual Actuated Boiler Blowdown Valves Installation and Maintenance Instructions 1. Safety information 2. General product information 3. Installation 4. Operation 5. Maintenance 6. Spare parts p.1 1. Safety
More information