Avenger Model 33M Installation & Operation Instructions

Similar documents
Genie Supreme TM Model 123HP Installation & Operation Instructions

Genie Supreme Model 123 Installation & Operation Instructions

Guardian Membrane Separators

Type 1367 High-Pressure Instrument Supply System with Overpressure Protection

INSTALLATION INSTRUCTIONS

61 Series Pilots for Pilot-Operated Pressure Reducing Regulators

FOR INSTALLING CO 2 BLENDER KIT (P/N IN BEER SYSTEM

Precision and Instrument Regulators 1/4" port size

NGP-250/500 Nitrogen Generator Quick Start Guide

B74G - EXCELON Modular System General purpose filter/regulator

1301 Series High-Pressure Regulators

94270 Vapor Guard Tank Blanketing Valve Vapor Guard Tank Blanketing Valve What is Tank Blanketing? Features How does it work?

Model Series 62 Constant Differential Relay

B84G - Excelon Plus Modular System General purpose filter/regulator

D05 Pressure Regulating Valves

2.0 INSTALLATION & SERVICE

Suggested Installation & Operating Instructions for Sidewinder Pumps

Go to Table of Contents. Ball and Plug Valves

High Precision Gauge Pressure Indicators

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER FILTER DRYER

Type ACE97. Introduction. Installation. P.E.D. Categories. Specifications. Overpressure Protection. Installation Guide English May 2002

Tank Blanketing Pressure Regulators RHPS Series

MLS Series Liquid Level Switches. Installation and Operations Manual Section 15

Model 10. Low-Medium Pressure Reducing Regulator

OPERATION MANUAL NTF-15

Storage Systems and Accessories

299H Series. Introduction. P.E.D. Categories. Specifications. Installation. Warning. Installation Guide English September 2012

Pneumatic Powered - Plunger Pumps

Type 1190 Low-Pressure Gas Blanketing Regulator

1805 Series Relief Valves

Installation and User Manual

BL68 - Olympian Plus, plug-in system Filter/regulators and lubricators

D05T Compact Design Pressure Regulating Valves

Type 310A-32A Pressure Reducing Regulator and Type 310A-32A-32A Working Monitor Regulator

1200 Series Pressure Regulators

Brooks Flow Controllers for Gas and Liquid Service Model FC 8744, Series FC 8800 and FC 8900

B84G - Excelon Plus Modular System General purpose filter/regulator

64 Series Pressure Reducing Regulators

Discontinued. Powers Controls. Technical Instructions Document No P25 RV Rev. 1, May, RV 201 Pressure Reducing Valves.

Proportional Relief Valves

INSTALLATION INSTRUCTIONS. CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION

Constant Pressure Crude Oil Container Model CPCCP

Product Manual. Description. Specifications. CVS Type 1301F and CVS Type 1301G Regulator. Introduction

Cash Valve TYPE G-4 PILOT OPERATED PRESSURE REDUCING REGULATOR FOR STEAM, AIR AND GASES. ISSUED - MARCH 2001 CAVMC-0512-US-0208 ISO 9001 Certified

SULLAIR SX Filtration Series ,000 scfm

Installation Operation Maintenance

DS05C,D,G Dial Set Pressure Regulating Valves

NEWS 66. VALVES & AIR SERVICE UNITS STEEL LINE Series

OPERATION MANUAL NTF-60 Plus

Installation, Operation and Maintenance Manual for Back Pressure Regulator

PRESSURE REGULATORS GAS PRESSURE REDUCING

Standard Operating and Maintenance Instructions for Pumping System Model PS-90

V DFX Series. Direct-Operated Tank Blanketing Regulator Manual D103808X012

KOZY Istallation Instructions

Float Operated Level Controllers

GILMONT ACCUCAL FLOWMETERS

IP2, IP2A and IP2D. Spirax-Monnier International Compressed Air Filter/ Regulators

PILOT OPERATED RELIEF VALVE SAFETY PRODUCTS THAT PROTECT EQUIPMENT, LIVES & THE ENVIRONMENT

CS Controlled Dissolved Gas assembly with optional CS Air Aspirator assembly. Installation and Operation information

Technical Information

1020 Industrial Drive, Orlinda, TN fax

North American Orifice Metering System

Installation Procedure for your Disco Double Kit, by Airgun Lab, LLC.

Air Preparation. Regulators, Pressure Regulators, Lubricators and Accessories. Keeping the World Flowing

NOTES. ITT CONOFLOW - QUICK REFERENCE GUIDE Airpak, Filter-Regulator / Filter Only

IP2M, IP2AM and IP2DM Monnier International Compressed Air Filter/ Regulators

V43 Pressure Actuated Water Regulating Valve

FILTER, REGULATOR AND FILTER/REGULATOR Stainless Steel 316L Compact 1/4, High Flow 1/4-1/2

Tech Tips. Service Call: Adjustable Hydraulic Valves Flow controls Pressure controls Sequence valves Holding valves

Pressure Dump Valve Service Kit for Series 3000 Units

Pressure Dump Valve Service Kit for Series 2300 Units

INDUSTRIAL EXCESS ESS FLOW VALVES

TYPE ECS SEAL METAL BELLOWS DRY-RUNNING SECONDARY CONTAINMENT Technical Specification

JR Series. Gas Pressure Reducing Valves. a division of Jordan Valve GAS PRESSURE REDUCING VALVES

TECHNICAL DATA. Trimpac 251a. Spetember 16, 2013

JR Series. Gas Pressure Reducing Valve GAS PRESSURE REDUCING VALVE

Rate of Flow Valve Series 120

PRO-50 Instrument Supply Regulator

SG3 Series Regulators - Pressure Reducing

T208VR Series Tank Blanketing Vacuum Regulator

THE MF-400 SERIES. Operating and Service Manual. Series includes all variants of MF-400/401

INSTRUMENTATION VALVES

Instruction Manual Updated 7/26/2011 Ver. 2.2

1200B2 Series Service Regulators. Instruction Manual

Standard Operating and Maintenance Instructions for Pumping System Model PS-150

PRESSURE REGULATORS GAS PRESSURE REDUCING

Part No (Low Changeover) Part No (High Changeover) Part No (High Changeover)

Propor tional Re lief Valve s

PRESSURE REGULATORS GAS BACK PRESSURE NON VENTING

TECHNICAL DATA. Trimpac 244a. September 16, 2013

Series V48. 3-Way Pressure Actuated Modulating Valves. Product Bulletin. Features. Pressure balanced design. Free movement of all parts

Installation, Operation, and Maintenance Manual

Cash Valve. Type G-4. Pilot Operated Pressure Reducing Regulator for Steam, Air and Gases. Flow Control

Installation, Operation & Maintenance Manual for Flo-Max Coupler Bracket Model FM150

TECHNICAL DATA. TRIMPAC Model B-5 & B-5B

TECHNICAL DATA. than the water inlet pressure to the concentrate

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25

Premium Series. Economical Price & Reliable Performance. High Quality. Rust-Resistant. Long Life. Tamper-Resistant locking Screw.

TECHNICAL DATA MAINTENANCE AIR COMPRESSOR MODEL G-1

HIGH-PRESSURE RELIEF VALVES

Transcription:

Avenger Model 33M Installation & Operation Instructions Manufacturing Contact Information A+ Corporation, LLC Call for expert product application assistance: 41041 Black Bayou Rd. Gonzales, LA 70737 Phone: (225)-644-5255 Website: www.geniefilters.com Fax: (225)-644-3975 E-mail: sales@geniefilters.com! Safety Warnings Failure to abide by any of the safety warnings below may result in equipment failure and serious injury or death. For models containing Liquid Block : Slowly open the supply pressure so that the minimum differential pressure required to shut-off the Liquid Block is not met or exceeded.. Valve off the sample flow before installation. Do not exceed any equipment pressure ratings. Tools Required Four #10 screws for mounting bracket to panel. Screwdriver for mounting bracket to panel. An ISO 9001:2008 certified company

Technical Specifications Technical Specifications Maximum pressure rating Maximum recommended supply pressure Maximum Liquid Block valve auto-reset pressure Maximum temperature Maximum recommended membrane flow rate (For higher flow rates contact the factory) Element size Port sizes Number of ports Internal volume Wetted materials Dimensions Back View 1,000 psig Lowest possible pressure consistent with application 85 psig* *Slowly open the supply pressure so that the minimum differential pressure required to shut off the Liquid Block is not met or exceeded 185 F (85 C) for Type 6 membrane 302 F (150 C) for Type 7 membrane 4,000 cc/min for Type 6 membrane 18,000 cc/min for Type 7 membrane *Maximum flow results in approximately 2 psi membrane differential pressure Outside Diameter: ~ 1.4 Inside Diameter: ~ 1.0 Length: ~ 2.5 Inlet, Outlet, & Bypass: 1/2 female NPT Gauge: 1/4 female NPT 5 200 cc Machined parts: 316/316L stainless steel / NACE compliant All other metal parts: stainless steel / NACE compliant Sealing material: Fluoroelastomer standard Membrane: inert Side View 3.000 2.250 MINIMUM MAINTENANCE CLEARANCE 8.250 5.144 4.420 2.000 DIA. 4.670 4.223 4.670 3.592 2.875 PORT D 1.414 An ISO 9001:2008 certified company 2 OPTIONAL MOUNTING BRACKET 0.544

Installation Instructions Install the mounting bracket onto the Avenger Model 33M or 38M as per the Mounting Bracket Installation Instructions included in A+ Corporation Mounting Bracket Kit P/N 33-509SS for Model 33M or P/N 38-509SS for Model 38M. Aftermarket brackets may be mounted as per the mounting diagrams below. Mount the Avenger horizontally as shown in the diagram. Lock washers may be used on the lower 10-32 screws to tilt the filter as shown to ensure that liquids drain properly. Port D should be facing down as shown. An optional downstream pressure gauge may be installed in Port E or it may be plugged. The Model 33M has 1/2 NPT ports (except for the 1/4 NPT gauge Port E ) and the Model 38M has 1/4 NPT ports. Refer to the Application for tubing connection instructions. Application Drawing An ISO 9001:2008 certified company 3

Application Drawing An ISO 9001:2008 certified company 4

Model Numbering & Additional Part Numbers Model Numbering & Additional Part Numbers Your model number is determined by your specific needs. Choose options below. Sealing material 0 = Fluoroelastomer 1 = Perfluoroelastomer (other materials available upon request) Element type 07CFS = 0.1 micron coalescer fluorocarbon SS10 = 10 micron stainless steel Membrane type 6 = Rejects ALL types of liquids from vapor 7= Rejects ONLY high surface tension liquids Liquid Block Blank = No Liquid Block L = Liquid Block Mounting bracket accessory Part # 33-509SS (sold separately) How to build the model number: 33M 3/2 S Sealing material Element type Membrane type Liquid Block option How to build the replacement filter element number: Element type 30 5 5 How to build the replacement o-ring kit number: 33M 5 0 Sealing material How to build the replacement membrane kit number: 33M 5 0 Membrane type Replacement filter and membrane kits contain 5 each. O-ring replacement kit contains all assembly o-rings. We cannot recommend specific sealing materials due to the complex nature of sample stream compositions. Temperature and pressure also may be factors. Unless specified otherwise, the product will ship with our standard sealing materials and materials of construction stated in the technical specifications section of the corresponding Product Sheet. Please refer to dupontelastomers.com for sealing material recommendations and advice. It is the user s responsibility to specify the sealing materials of construction for their application. An ISO 9001:2008 certified company Genie, Avenger ȚM Liquid Block TM and Genie Membrane Technology TM are trademarks or registered trademarks of A + Corporation, LLC. All other referenced trademarks are the property of their respective owners.