CV3000 Series Pressure Balanced High-Pressure Cage type Control Valves

Similar documents
3" 24" 80A 600A DN80 DN600 Body size The largest size manufactured : 60" (1500A) Disc form Damper type Trim materials Trim treatment

PNEUMATIC CONTROL VALVES PV25 (ANSI) V25S globe control valves with linear actuators PA series

Series 44 Self-operated Pressure Regulators. Type 44-0 B Pressure Reducing Valve. ANSI version

Pibiviesse High Performance Control Ball Valve

Direct Operated Precision Regulator Modular Style. Standard Specifications

PNEUMATIC CONTROL VALVES PV25 (EN) V25G globe control valves with linear actuators PA series

Pressure Reducing Valve DMV 755

Pneumatic Control Valve PV25 (EN)

Simple Set Max. Pressure Independent Control Valves 2 Way 2-1/ /09/18

MZX. Three-Port Seat Valves SPECIFICIATIONS AND GUIDE TO SELECTION

COMMITTEE DRAFT. API 520 Part I 10 th Edition Ballot Item 2.1. This ballot covers the following item:

PRESSURE REGULATORS UPSTREAM DIFFERENTIAL PRESSURE. APPLICATION: For maintaining a constant differential pressure across meter.

Series 42 Self-operated Regulators Differential Pressure Regulators with Type 2424/Type 2428 Actuator (closing) Type Type 42-28

Series 44 Self-operated Pressure Regulators. Type 44-1 B Pressure Reducing Valve. Type 44-6 B Excess Pressure Valve. ANSI version

Booster Regulator/Air Tank

KF Series Liquid Level Indicating Controller

PRESSURE REGULATORS GAS PRESSURE REDUCING

Manual Actuated Boiler Blowdown Valves

Precision and Instrument Regulators 1/4" port size

Electro-Pneumatic Valve Positioners

ASX 176 Axial Pressure regulator

Type 1098-EGR. Pilot-Operated Valve Link Regulators. Features. Fisher Controls

Technical Data Sheet T 2025

2-port and 3-port valves PN 16

PNEUMATIC ACTUATED INDUSTRIAL VALVES SERIES:

WHEATLEY WHEATLEY SERIES 500 SWING CHECK VALVE. Installation, Operation and Maintenance Manual

Liquid Level Indicating Controller

ROTATING DISK VALVES INSTALLATION AND MAINTENANCE 1. SCOPE 3 2. INFORMATION ON USAGE 3 3. VALVE TYPES 3 4. OPERATORS 5 5. VALVE CONSTRUCTION 6

TECHNICAL INSTRUCTIONS Iron Body Series 597 SI

Self-operated Pressure Regulators Type Universal Pressure Reducing Valve

BTV. Internally threaded 2-way control valve. Flow characteristics. Function

WHEATLEY Series 500 Swing Check Valve

Type 4708 Supply Pressure Regulator

Slam Shut Valves SCN

PRESSURE REGULATORS GAS PRESSURE REDUCING

BERMAD Waterworks. Level Control Valve with Altitude Pilot. 700 Series. Model X. Features and Benefits. Major Additional Features

2-Port Seat Valves with Flange, PN 16

STANDARD FOR CONTROL VALVE SEAT LEAKAGE

Pressure and Temperature Controls

Type 92S Pilot-Operated Steam Regulator

INSTALLATION INSTRUCTIONS. CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION

Ball Float Steam Trap UNA 43 PN 16/CL 125/JIS 10K UNA 46 PN 40/CL 150/CL 300/JIS 10K/JIS 20K DN 80, 100, 150, 3", 4", 6"

Materials : Forged carbon steel A350 LF2

Type ACE97. Introduction. Installation. P.E.D. Categories. Specifications. Overpressure Protection. Installation Guide English May 2002

3-1. Safety Relief Valve

Type 4708 Supply Pressure Regulator

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS

Types 1098-EGR and 1098H-EGR Pressure Reducing Regulators

NAF-Trimball Control Ball Valves

Leak testing of Valves. Standards for acceptable Rates of Valve Leakage

FILTER BYPASS CONTROL

Cash Valve TYPE G-4 PILOT OPERATED PRESSURE REDUCING REGULATOR FOR STEAM, AIR AND GASES. ISSUED - MARCH 2001 CAVMC-0512-US-0208 ISO 9001 Certified

Type 4708 Supply Pressure Regulator

Pressure Reducing Valve DMV 750 set range: bar

Petrofac Client Doc. No JI-DTS-5002 Page 2 of 8 Rev. TABLE OF CONTENTS

Models 461-S, 461-8S and S Regulators. R-1330 Rev. 7

Pressure Reducing Valve DMV 750

2-Port Seat Valves with Flange, PN 16

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS

CVI Valve Line. Exceeds the industry s highest standards for reliability and performance

Telefon (+45) Telefax (+45)

BACK PRESSURE / SUSTAINING

Pressure relief valve DHV 712 DN 65-80: 0,5-10 bar, DN : 0,3-4 bar, DN 100: 0,5-6 bar

Ball Float Steam Trap UNA 45 MAX, UNA 46 MAX, UNA 46A MAX PN 40/Class 300 DN 40, 50, 65

Pressure Regulating Valves. Models 44, 77 & 68 PS\ UL. Pressure Relief Valve. Dorot Fire Protection Division. Certification & compliance by design

Pressure and/or Temperature Pilot Operated Steam Regulators Series 2000

2-port seat valves PN25 with externally threaded connections

Materials : Forged carbon steel A105N

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly.

BERMAD Irrigation. IR-100 hyflow Basic Valve. Basic Valve.

CONTROL VALVE TESTING

PRESSURE REGULATORS GAS BACK PRESSURE NON VENTING

VG Series VGG and VGD Gas Valves for use with SKP Electro-hydraulic Actuators

Appendix A Frequently Asked Questions

VALFONTA INSTRUCTIONS: OPERATION AND INSTALLATION PRESSURE REDUCING VALVE MODEL M2

Pilot Check Valve: Metal Body Type

Technical Instructions

Type 299 Pressure Reducing Regulators

Simple Set. Pressure Independent Control Valves 2 Way 1/2-2

94270 Vapor Guard Tank Blanketing Valve Vapor Guard Tank Blanketing Valve What is Tank Blanketing? Features How does it work?

DS05C,D,G Dial Set Pressure Regulating Valves

DS MZ, MZF, MJF THREE-PORT SEAT VALVES

Pilot Assembly Motor Valve Stem Assembly Upstream Pressure Downstream Pressure Motor Valve Diaphragm Pressure. Adjusting Screw.

The Shand & Jurs Model Vapor Guard Tank Blanketing Valve

valves and actuators SUBSEA ACTUATION

Dual position solenoid valve Type ICSH 25-80

Pressure Independent Control Series

Type 310A-32A Pressure Reducing Regulator and Type 310A-32A-32A Working Monitor Regulator

Solenoid valves VZWF, force pilot operated

Flange (JIS) Socket Weld 10 A, 15 A 20 A, 25 A 10 K, 20 K, 30 K 40 K, 63 K

2-step solenoid valve Type ICLX

2-step solenoid valve Type ICLX

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25

1/2 to 2-1/2 NPT; 0 to 230 PSI Advantages / Benefits

Integral type Differential pressure flowmeter VNT Series

Types 1098-EGR and 1098H-EGR Pressure Reducing Regulators

Series 8R HIGH PERFORMANCE

V43 Pressure Actuated Water Regulating Valve

Cash Valve. Type G-4. Pilot Operated Pressure Reducing Regulator for Steam, Air and Gases. Flow Control

Line Blind Valves. Double Block and Bleed Cargo Segregation API 607. Fire Safe Certified

Transcription:

OVERVIEW CV3000 Series Pressure Balanced High-Pressure Cage type Control Valves Model HPC Model HPC Pressure balanced high-pressure cage type Control Valves are design for high temperature, high pressure services. The compact valve body, having a S-shade flow passage that features low pressure loss and a stabilizer that regulates turbulent flow around the cage, allows a large flow capasity and rangeability. The valve plug is structured in a pressure balanced type that permits flow control of a high differential pressure with a small actuating force. The actuator integrated with simplest mechanisms utilizes a compact yet powerful diaphragm actuator loaded with multiple springs. The HPC Valves are widely applicable for reliable control of high temperature, high pressure or high differential pressure process lines where dynamic stability, low noise, and cavitation resistance are required. SPECIFICATIONS Body Type Straight through, cast globe valve Nominal size 1½, 2, 3, 4, 6, 8 inches Pressure rating JIS 63K ANSI Class 900, 1500, 2500 JPI Class 900, 1500, 2500 End connection Flanged end; Connection type Pressure rating Applicable standard JIS B2210-1984 RF ANSI Class 900, 1500, 2500 ANSI B16.5-1981 JPI Class 900, 1500, 2500 JPI-7S-15-1993 RJ ANSI Class 900, 1500, 2500 ANSI B16.5-1981 JPI Class 900, 1500, 2500 JPI-7S-15-1993 Welded end; SW (1½, 2, 3 inches) BW (3 to 8 inches) Material For body/trim material combinations and operating temperature ranges, refer to Table 1. Bonnet Plain bonnet (-5 to 230 C) Extension bonnet type 1 (230 to 566 C) Note) Take care not to exceed the operating temperature ranges specified for respective materials. Gland type Bolted gland Packing/Grease Grease not provided When V shaped PTFE packing or PTFE yarn packing is used. Grease provided When graphite packing is used. Gasket Type Combination of serrated type and flat type Material Stainless steel (SUS316) or others Specifications are subject to change without notice. - 1 - This product is designed for general industrial use.

Trim Valve plug Pressure balanced type Cage (split cage) Equal percentage(%v) Linear cage (LV) Material For body/trim material combinations and operating temperature ranges, refer to Table 1. Type Single acting diaphragm actuator (Type HA or VA5) Spring Type piston actuator (Type PSA6) Double acting piston actuator (Type VP) Action Direct or reverse action Diaphragm Type HA : Cloth embedded ethylene propylene rubber Type VA : Cloth embedded chloroprene rubber Spring range Type HA, Type VA5 {0.4 to 2.0 kgf/cm²} {0.8 to 2.4 kgf/cm²} Type PSA6 200 to {2.0 to 3.5 kgf/cm²} 200 to {2.0 to 4.0 kgf/cm²} Diaphragm actuator Type HA : to {2.8 to 4.0 kgf/cm²} Type VA5 : {2.8 kgf/cm²} Spring type piston actuator Type PSA6:400 to 490 {4.0 to 5.0 kgf/cm²} Piston actuator Type VP : 290 to 490 {3.0 to 5.0 kgf/cm²} Note) Allowable differential pressure varies depending on spring range and air supply pressure. Air connection: Rc1/4 or 1/4NPT internal thread Note) With type VA or VP, Rc1/4 or 1/4NPT adapter is provided on Rc½ internal thread (also providing Rc3/8 adapter is possible). Ambient temperature -30 to 70 C Valve action Air-to-close (Direct action actuator is combined.) Air-to-open (Reverse action actuator is combined.) Optional accessories Positioner*, pressure regulator with filter, hand wheel*, limit switch, solenoid valve, motion transmitter, booster relay, lock-up valve, and others. Note) For the optional items, refer to the specification sheets and installation drawings of respective accessaries. Positioner Hand wheel P/P I/P Top Side HA3, 4 HTP AVP/HEP THM SHM VA5 HTP AVP/HEP THM SHM PSA6 HTP/VPP AVP/HEP - SHM VP5, 6 VPP AVP/HEP - SHM Additional specification (by special order) Special inspection Flow characteristics inspection, material inspection (Material certificate ), non-destructive inspection, steam inspection. With drain plug Double gland Oil/Water free treatment Copper free treatment Yoke material SCPH2 Stainless steel (SUS304) atmosphere-exposed nuts and bolts Special air piping and joint Sand-/dust-preventive measures Saline damage countermeasures Cold-area use specifications Tropical-area use specification Performance Rated Cv value Refer to Table 2. Flow characteristics Refer to Figure 1. Inherent rangeability 50 : 1 Allowable differential pressure Refer to Table 3 to Table 11 Leakage specification IEC 60534-4:2006 or JIS B 2005-4:2008 Metal seat Standard...Class III: Leakage less than 0.1% of maximum valve capacity. Hysteresis error With positioner Within 1% F.S. (Within 2% F.S.) Linearity With positioner: Within ±1% F.S. (Within ±2% F.S.) Note) Parenthesized figures are applicable to type PSA6. Dimensions Refer to Figure 2, Table 12 and Table 13. Weight Refer to Table 14. orientation Refer to Figure 3. Finish Blue (Munsell 10B5/10) or silver, or other specified colors. - 2 -

Table 1 Body / trim material combinations and operating temperature ranges ( C) Body material JIS body SCPH 2 SCPH 21 SCPH 32 SCPH 61 SCS 13A SCS 14A bonnet SFVC2A SFVCF11A SFVAF22B SFVAF5B SUSF304 SUSF316 Trim material ASTM body A216 WCB A217 WC6 A217 WC9 A217 C5 A351 CF8 A351CF8M*1 bonnet A105 A182F11 A182F22 A182F5 A182F304 A182F316 Valve plug Cage Seat ring SUS 630C SUS 630 (SCS24)*2 SUS 630 (SCS24)*3-5 to 425-5 to 425-5 to 425-5 to 425 - - SUS 304 Atomlloy treatment (SCS 13A Atomlloy treatment)*2 (SCS 14A Stellite)*3 SUS 304 Atomlloy treatment SUS 316 Stellite -5 to 425-5 to 500-5 to 500-5 to 500-5 to 500-5 to 500*1 SUS 316 Stellite SUS 304 Atomlloy treatment SUS 316 Stellite (SCS 13A Atomlloy treatment)*2 (SCS 14A Stellite)*3-5 to 425-5 to 500-5 to 500-5 to 500-5 to 500-5 to 500*1 SUS 316 Stellite SUS 316 face+atomlloy treatment SUS 316 Stellite Stellite face (SCS 14A Stellite face+ (SCS 14A Stellite)*3-5 to 425-5 to 550-5 to 556-5 to 556-5 to 550-5 to 550*1 Atomlloy treatment)*2 Note) 1) " " shows standard combination of valve body and trim material. 2) *1: For ASTM A351CF8M, the maximum temperature can be +566 C. 3) *2: When the nominal size is 3 inches or over, the equivalent cast material shown in parenthesis is applied. 4) *3: When the nominal size is 4 inches or over, the equivalent cast material shown in parenthesis is applied. 5) The standard material for piston ring is Ni-resist. When a valve needs oil-free treatment or is used for high temperature fluid more than 230 C, the piston ring material is changed to Stellite #21. Table 2 Cv value and travel Rated Cv value Nominal size (inches) 1½ 2 3 4 6 8 Port size (inches) 1 1 ¼ 1 ½ 1 ¼ 1 ½ 2 2 2 ½ 3 2 ½ 3 4 4 5 6 5 6 8 Equal percentage (%V) Equal percentage (%V) JIS 63K ANSI 900, 1500 ANSI 900, 1500 12 17 25 17 25 52 52 78 110 78 110 180 180 375 375 650-12 17 12 17 31 31 52 78 52 78 125 125 180 180 470 12 20 30 20 30 62 62 90 135 90 135 210 210 330 485 330 485 700-12 20 12 20 43 43 62 90 62 90 150 150 210 330 210 330 520 Rated travel (mm) 25 38 50 75 100 50 100 80 Cv value (%) 20 10 Cv value (%) 60 40 5 20 2 0 20 40 60 Travel (%) 80 100 0 0 20 40 60 Travel (%) 80 100 a. Equal percentage characteristics (%C) b. Linear characteristics (LC) Figure 1 Flow characteristics Note) The above graphs indicate typical flow characteristics. - 3 -

Allowable differential pressure Metal seat (%L, LV) : PTFE packing Valves with type HA or VA actuator Table 3 Air-to-close ANSI 900, 1500 HA3D HA4D VA5D HA3R HA4R VA5R 290 {3.0} 290 {3.0} 290 {3.0} 290 {3.0} Spring range Differential pressure (by port size(inches)) 1 ½ 2 3 4 6 8 25600 {261} 20700 {211} 25800 {263} 33200 {339} 25600 {261} 37000 {377} 30000 {30} 20700 {211} 25800 {263} {440] {289} 41200 {420} 11400 {116} 18600 11400 {116} 24300 {248} {233} {233} {25.9} 19700 {201} 19700 {201} 11400 {116} 18600 11400 {116} 24300 {248} {233} 27200 {277} {233} 41500 {423} 19700 {201} 35200 {359} 19700 {201} 35200 {359} 19700 {201} 39500 {403} 7650 {78.0} 11100 {113} 7650 {78.0} 14900 {152} 15300 {156} 16900 {172} 15300 {156} 22300 {227} 10400 {106} 16600 {169} 10400 {106} 21800 {222} 20800 {212} 24400 {249} 20800 {212} 37400 {381} 17900 {183} 31800 {324} 17900 {183} 40700 {415} {289} 36000 {367} 5690 {58.0} 7260 {74.0} 5690 {58.0} 10100 {103} 11500 {117} 11600 {118} 11500 {117} 18700 {191} 9900 {100} 15600 {159} 9900 {100} {210} 19800 {202} 23000 {235} 19800 {202} 13500 {138} 22900 {234} 6960 {71.0} 9710 {99.0} 6960 {71.0} 10 {142} 10 {142} 23700 {242} 12100 {123} 19900 {203} 12100 {123} 26000 {265} 24100 {246} 28900 {295} 24100 {246} 16500 {168} 28800 {294} 6280 {64.0} 6280 {64.0} 7650 {78.0} 11500 {117} 6570 {67.0} {91.0} 6570 {67.0} 12200 {125} 10 {142} 22200 {226} 9020 {92.0} 13800 {141} 4310 {44.0} 4410 {45.0} 4310 {44.0} 6570 {67.0} 7650 [78.0} 7650 [78.0} 8630 {88.0} 13100 {134} 7450 {76.0} 10800 {110} 7450 {76.0} 14500 {148} 16400 {167} 25800 {263} 10200 {104} 16300 {166} Note) 1) " " shows a model with standard actuator. 2) Positioner is employed in general. 3) Allowable differential pressure at valve-close in the above table is under the condition of P P1 (P2 0). Allowable differential pressure at full closure varies depending on the outlet pressure (P2). Detailed information is avail able on request. 4) Take care not to cause the maximum allowable differential pressure to exceed the maximum operating pressure designated by ANSI B16. 34-1981 or JIS B2201-1984. 5) Take care not to cause the inlet pressure (P1) to exceed allowable differential pressure at full closure. 6) The upper figures denote the operating allowable differential pressure. The lower denote the allowable differential pressure at full closure. 4900 {50.0} 5590 {57.0} 4900 {50.0} 8140 {83.0} 9320 {95.0} 9320 {95.0} 9900 {101} 15500 {158} 6770 {69.0} 9320 {950} 6570 {67.0} {91.0} 6570 {67.0} 12200 {125} 10 {142} 22200 {226} 9020 {92.0} 13800 {141} - 4 -

Table 4 Air-to-open ANSI 900, 1500 HA3R HA4R VA5R PSA6R HA3R HA4R VA5R PSA6R 290 {3.0} 290 {3.0} 400 500 {5.1} 290 {3.0} 290 {3.0} 490 {5.0} Spring range 200 to {2.0 to 3.5} 200 to {2.0 to 4.0} 200 to {2.0 to 3.5} 200 to {2.0 to 4.0} Differential pressure (by port size(inches)) 1 ½ 2 3 4 6 8 11400 7650 5690 {116} {78.0} {58.0} 18600 20700 {211} 18600 20700 {211} 18600 17200 Note) 1) " " shows a model with standard actuator. 2) Positioner is employed in general. 3) Allowable differential pressure at valve-close in the above table is under the condition of P P1 (P2 0). Allowable differential pressure at full closure varies depending on the outlet pressure (P2). Detailed information is avail able on request. 4) Take care not to cause the maximum allowable differential pressure to exceed the maximum operating pressure designated by ANSI B16. 34-1981 or JIS B2201-1984. 5) Take care not to cause the inlet pressure (P1) to exceed allowable differential pressure at full closure. 6) The upper figures denote the operating allowable differential pressure. The lower denote the allowable differential pressure at full closure. 11100 {113} {175} 11100 18600 {113} {233} 19700 {201} {210} 11400 {116} 18600 17200 {175} 18600 18500 22300 {227} 19900 {203} 22300 {227} {210} 22300 {227} 10400 {106} 16600 {169} {189} 16600 18600 {169} 19700 18500 {201} {189} 35200 31800 {359} {324} {210} 35200 {359} 7260 {74.0} 7260 {74.0} 9900 {110} 15600 {159} 14900 {152} 15600 {159} 15600 {159} 15600 {159} 13500 {138} 22900 {234} 6960 {71.0} 9710 {99.0} 15600 {159} 9710 16600 {99.0} {169} {210} 31800 {324} 6570 {67.0} {91.0} {91.0} {91.0} 9020 {92.0} 13800 {141} 18700 {191} 4310 {44.0} 4410 {45.0} 4310 {44.0} 4410 {45.0} 12100 7450 {123} {76.0} 19900 10800 {203} {110} 1800 {184} 10800 19900 {110} {203} 19900 {203} 24.1 {246} 43.1 35500 {362} 21200 {216} 36100 {368} 4900 {50.0} 5590 {57.0} 5590 {57.0} 5590 {57.0} 6770 {69.0} 9320 {950} 6570 {67.0} {91.0} {91.0} - 5 -

Valves with type VP actuator Table 5 Air-to-close and Air-to-open ANSI 900, 1500 ANSI 900, 1500 Nominal size(inches) VP5 6 VP6 8 290 490 Differential pressure 19400 {198} 23700 {242} 19400 {198} 27600 {281} 18700 {191} 18800 {192} 38100 {389] 2500 {255} 25000 {255} 32400 {330} 31300 {319} Note) 1) Positioner is employed in general. 2) In case a back-up system is used for pressure drop of supply air, select the allowable differential pressure whichever is lower-the operating supply air pressure or the back-up system set pressure (trip pressure). 3) Allowable differential pressure at valve-close in the above table is under the condition of P P1 (P2 0). Allowable differential pressure at full closure varies depending on the outlet pressure (P2). Detailed information is avail able on request. 4) Take care not to cause the maximum allowable differential pressure to exceed the maximum operating pressure designated by ANSI B16. 34-1981 or JIS B2201-1984. 5) Take care not to cause the inlet pressure (P1) to exceed the allowable differential pressure at full closure. 6) The upper figures denote the operating allowable differential pressure. The lower denote the allowable differential pressure at full closure. - 6 -

Metal seat (%L, LV) : Graphite packing "P6610CH+P6528" (+230 to +500 C) Valves with type HA or VA actuator Table 6 Air-to-close ANSI 900, 1500 HA3D HA4D VA5D HA3R HA4R VA5R Supply pressure {kgf/cm² Spring range Differential pressure (by port size(inches)) 1 ½ 2 3 4 6 8 25600 {261} 20900 {213} {232} 25600 {261} 20900 27300 {213} {278} 30000 {305} {288} 41200 {420} {232} 38100 {388} {288} 40200 {409} 39500 {402} 14000 {142} 15300 {156} 25500 {260} 19000 {193} 20800 {212} 34700 {353} {288} 36600 {373} 36000 {367} 10500 {107} 11500 {117} 18700 19800 {202} 20300 {207} 19800 {202} 10 {129} 12800 {130} 10 {141} 20 {238} 6280 {64.0} 6280 {64.0} 6280 {64.0} 11500 {117} 13500 {137} 22200 {226} 8490 {86.5} 7650 {78.0} 8600 {87.6} 13100 {133} 24100 {245} 14500 24700 {147} {251} 24100 {245} 42900 {437} 15400 {157} {152} 25800 {263} 9790 {99.8} 9320 {95.0} 9900 {100} 15500 {158} 6380 {65.0} 12200 {124} {134} 22200 {226} 8490 {86.5} Note) 1) Positioner is employed in general. 2) Allowable differential pressure at valve-close in the above table is under the condition of P P1 (P2 0). Allowable differential pressure at full closure varies depending on the outlet pressure (P2). Detailed information is avail able on request. 3) Take care not to cause the maximum allowable differential pressure to exceed the maximum operating pressure designated by ANSI B16. 34-1981 or JIS B2201-1984. 4) Take care not to cause the inlet pressure (P1) to exceed the allowable differential pressure at full closure. 5) The upper figures denote the operating allowable differential pressure. The lower denote the allowable differential pressure at full closure. - 7 -

Table 7 Air-to-open ANSI 900, 1500 JPI 900, 1500 HA3R HA4R VA5R PSA6R HA3D HA4D VA5D PSA6R 400 500 {5.0}\ 400 500 {5.0}\ Spring range 200 to {2.0 to 3.5} 200 to {2.0 to 4.0} 200 to {2.0 to 3.5} 200 to {2.0 to 4.0} Differential pressure (by port size(inches)) 1 ½ 2 3 4 6 8 18400 {187} 20700 {211} 18400 {187} 37000 {377} 14000 {142} 9440 {96.2} {210} 19000 {193} 14000 {142} {210} {288} 12800 {130} 7100 {72.3} 14300 {145} 13500 {137} 19500 {198} 8640 {88.1} {210} 17400 25800 {177} {263} 16500 {168} 23800 {242} 35500 {361} {439} {90.9} 9020 {91.9} 13100 {133} 18700 4300 {43.8} 4400 {44.8} 10800 {110} 10200 {104} 15100 21200 {216} 36100 {368} 5590 {57.0} 6770 {69.0} 9320 {95.0} {90.9} 9020 {91.9} 13100 {133} Note) 1) Positioner is employed in general. 2) Allowable differential pressure at valve-close in the above table is under the condition of P P1 (P2 0). Allowable differential pressure at full closure varies depending on the outlet pressure (P2). Detailed information is avail able on request. 3) Take care not to cause the maximum allowable differential pressure to exceed the maximum operating pressure designated by ANSI B16. 34-1981 or JIS B2201-1984. 4) Take care not to cause the inlet pressure (P1) to exceed the allowable differential pressure at full closure. 5) The upper figures denote the operating allowable differential pressure. The lower denote the allowable differential pressure at full closure. - 8 -

Valves with type VP actuator Table 8 Air-to-close and Air-to-open ANSI 900, 1500 VP5 VP6 VP5 VP6 Differential pressure 6 8 Note) 1) Positioner is employed in general. 2) When a back-up system for pressure drop of supply air souce is used, select the allowable differential pressure whichever is lower-constant supplied air pressure or back-up system set pressure (trip pressure). 3) Allowable differential pressure at valve-close in the above table is under the condition of P P1 (P2 0). Allowable differential pressure at full closure varies depending on the outlet pressure (P2). Detailed information is avail able on request. 4) Take care not to cause the maximum allowable differential pressure to exceed the maximum operating pressure designated by ANSI B16. 34-1981 or JIS B2201-1984. 5) The upper figures denote the operating allowable differential pressure. The lower denote the allowable differential pressure at full closure. 490 {5.0} 27700 {282} 00 {346} 26400 {269} {439} - 9 -

Metal seat (%L, LV) : Graphite packing "P6610CH+M8590" (+500 to +566 C) Valves with type HA or VA actuator Table 9 Air-to-close ANSI 900, 1500 HA3D HA4D VA5D HA3R HA4R VA5R Spring range Differential pressure (by port size(inches)) 1 ½ 2 3 4 6 8 21900 {223} 21900 {223} 30000 {305} {439} {288} {439} 41200 {420} {439} 16800 {171} {232} 16800 {171} {232} 30 {345} {288} 35100 {357} 39500 {402} {439} 11200 {114} 15300 {156} {232} 23500 {239} 15300 {156} 20800 {212} 30900 {315} 8490 {86.5} 11500 {117} 17100 {174} 17700 {180} 19800 {201} 7780 {79.3} 10300 {105} 10 {141} 20800 {212} {288} 21500 31900 {219} {325} 36000 {367} {439} 24100 {245} 39800 {405} 9470 {96.5} 5680 {57.9} 6280 {64.0} 11400 {116}} 11800 {120} {134} 21800 {222} 5200 {53.0} 6540 {66.6} 8600 {87.6} 13100 {133} 13600 {138} {152} 25200 {256} 6000 {61.1} 8910 {90.8} 9900 {100} 15500 {158} 3910 {39.8} 11800 {120} {134} 21800 {222} 5200 {53.0} Note) 1) Positioner is employed in general. 2) Allowable differential pressure at valve-close in the above table is under the condition of P P1 (P2 0). Allowable differential pressure at full closure varies depending on the outlet pressure (P2). Detailed information is avail able on request. 3) Take care not to cause the maximum allowable differential pressure to exceed the maximum operating pressure designated by ANSI B16. 34-1981 or JIS B2201-1984. 4) Take care not to cause the inlet pressure (P1) to exceed the allowable differential pressure at full closure. 5) The upper figures denote the operating allowable differential pressure. The lower denote the allowable differential pressure at full closure. - 10 -

Table 10 Air-to-open ANSI 900, 1500 HA3R HA4R VA5R PSA6R HA3D HA4D VA5D PSA6R 400 500 {5.0}\ 400 500 {5.0}\ Spring range 70 to 230 {0.7 to 2.3} 200 to {2.0 to 3.5} 200 to {2.0 to 4.0} 70 to 230 {0.7 to 2.3} 200 to {2.0 to 3.5} 200 to {2.0 to 4.0} Differential pressure (by port size(inches)) 1 ½ 2 3 4 6 8 13000 {132} 20700 {211} 13000 {132} 20700 {211} 30400 {309} 9950 6680 {101} {68.1} {210} 15600 23200 {159} {236} 9950 {101} {210} 23200 {236} 5020 {51.1} 11700 {119} 7700 {78.5} 9060 6110 {92.3} {62.3} {210} 14200 21100 {144} {215} 9400 {95.8} 27700 {282} {439} 7850 {80.0} 5200 {53.0} 18700 3870 {39.4} 9050 {92.2} 6000 {61.1} 21200 {216} 36100 {368} 5590 {57.0} 3910 {39.8} 7850 {80.0} 5200 {53.0} Note) 1) Positioner is employed in general. 2) Allowable differential pressure at valve-close in the above table is under the condition of P P1 (P2 0). Allowable differential pressure at full closure varies depending on the outlet pressure (P2). Detailed information is avail able on request. 3) Take care not to cause the maximum allowable differential pressure to exceed the maximum operating pressure designated by ANSI B16. 34-1981 or JIS B2201-1984. 4) Take care not to cause the inlet pressure (P1) to exceed the allowable differential pressure at full closure. 5) The upper figures denote the operating allowable differential pressure. The lower denote the allowable differential pressure at full closure. - 11 -

Valves with type VP actuator Table 11 Air-to-close and Air-to-open ANSI 900, 1500 VP5 Differential pressure 6 8 {264.0} VP6 {264.0} 32400 VP5 490 {330.0} {5.0} {439.0} 31900 VP6 {319.0} {439.0} Note) 1) Positioner is employed in general. 2) When a back-up system for pressure drop of supply air souce is used, select the allowable differential pressure whichever is lower-constant supplied air pressure or back-up system set pressure (trip pressure). 3) Allowable differential pressure at valve-close in the above table is under the condition of P P1 (P2 0). Allowable differential pressure at full closure varies depending on the outlet pressure (P2). Detailed information is avail able on request. 4) Take care not to cause the maximum allowable differential pressure to exceed the maximum operating pressure designated by ANSI B16. 34-1981 or JIS B2201-1984. 5) The upper figures denote the operating allowable differential pressure. The lower denote the allowable differential pressure at full closure. - 12 -

Dimensions Table 12 Face-to-face dimensions [Unit:mm] A Nominal size JIS 63K ANSI 900, JPI 900 ANSI 1500, JPI 1500, (inches.) RF RF(SW,BW) RJ RF(SW,BW) RJ RF(SW,BW) RJ 1½ 323 333 333 333 333 358 361 2 354 375 378 375 378 400 403 3 431 440 443 460 463 498 504 4 496 510 513 530 533 575 585 6 699 715 718 770 776 820 833 8 895 915 918 972 982 1020 1036 Table 13 External dimensions Nominal size (inches) 1½ 2 3 4 6 8 JIS 63K ANSI 900 JPI 900 Plain bonnet Extention bonnet H ANSI 1500 JPI 1500 Plain bonnet Extention bonnet Plain bonnet Extention bonnet HA 3D, R 735 875 735 875 780 725 363 350 HA 4D, R 890 1030 890 1030 935 1080 520 470 HA 3D, R 765 925 765 925 300 960 353 350 HA 4D, R 925 1085 925 1085 960 1120 520 470 HA 3D, R 800 980 800 980 835 1005 363 350 HA 4D, R 960 1140 960 1140 995 1165 520 470 HA 3D, R 835 1015 835 1015 880 1050 363 350 HA 4D, R 995 1175 995 1175 1040 1210 520 470 VA 5D 1380 1560 1380 1560 1425 1595 620 VA 5R 1490 1670 1490 1670 1535 1705 620 PSA 6R 1324 1504 1324 1504 1369 1539 475 HA 3D, R 895 1075 895 1075 935 1110 363 350 HA 4D, R 1055 1235 1055 1235 1095 1 520 470 VA 5D 1440 1620 1440 1620 1480 1655 620 VA 5R 1550 1730 1550 1730 1590 1765 620 PSA 6R 1395 1575 1395 1575 1435 1610 476 VP 5 1080 1260 1080 1260 1120 1295 345 HA 4D, R 1155 1395 1155 1395 1185 1370 520 470 VA 5D 1545 1785 1545 1785 1575 1760 620 VA 5R 1655 1895 1655 1895 1685 1870 620 [Unit:mm] VP 6 1395 1635 1395 1635 1425 1610 445 "H" dimensions are applicable when hand wheel is not provided. When top-mounted hand wheel HA or VA actuators or side-mounted hand wheel PSA6R or VP actuators are used, add the hand wheel dimensions designated in respective specification sheets (No. SS2-8213-0500 for type HA actuators, No. SS2-8210-0100 for type VA, SS2-PSA100-0100 for type PSA, and No. SS2-8210-0300 for type VP actuators). B C JIS 63K ANSI 900 JPI 900 E ANSI 1500 JPI 1500 100 105 115 110 120 130 140 150 165 160 170 195 210 225 260 280 290 330-13 -

B H H H H E E E E A A A A a. For HA actuator b. For VA5 actuator c. For PSA6 actuator d. For VP actuator Figure 2 Face-to-face and other dimensions Table 14 Weight [Unit:kg] Nominal size (inches), ANSI 900 JPI 900 Weight (Flanged connection) ANSI 1500 JPI 1500, ANSI 900 JPI 900 Weight (Welded connection) ANSI 1500 JPI 1500 Plain Extention Plain Extention Plain Extention Plain Extention Plain Extention Plain Extention bonnet bonnet bonnet bonnet bonnet bonnet bonnet bonnet bonnet bonnet bonnet bonnet 1½ HA 3D, R 60 (55) 65 (60) 65 70 90 95 50 55 55 60 75 80 HA 4D, R 90 (85) 95 (90) 95 100 125 130 80 85 85 90 405 110 2 HA 3D, R 70 (65) 80 (75) 75 85 110 120 55 65 60 70 85 95 HA 4D, R 100 (95) 110 (105) 105 115 140 150 85 95 90 100 115 125 3 HA 3D, R 105 (100) 115 (110) 140 160 225 245 85 95 110 30 170 190 HA 4D, R 135 (130) 145 (140) 170 190 255 275 115 125 140 160 200 220 HA 3D, R 135 (125) 160 (150) 195 225 315 345 105 130 155 185 230 260 HA 4D, R 165 (155) 190 (180) 225 255 345 375 135 160 185 215 260 290 4 VA 5D 265 (255) 290 (280) 325 355 445 475 235 260 285 315 360 VA 5R 290 (280) 315 (305) 350 380 470 500 260 285 310 385 415 PSA 6R (260) 275 (285) 330 360 450 480 240 265 290 320 365 395 HA 3D, R 345 (330) 380 (365) 525 570 85 915 285 320 435 480 660 700 HA 4D, R 395 (360) 410 (395) 555 600 905 945 315 350 465 510 690 730 6 VA 5D 475 (460) 510 (495) 655 700 1005 1045 415 450 565 610 790 830 VA 5R 500 (485) 535 (520) 680 725 1030 1070 440 475 590 635 815 855 PSA 6R 480 (465) 515 (500) 660 705 1010 1050 420 455 470 615 795 835 VP 5 (375) 425 (410) 570 615 920 960 330 365 365 525 705 745 HA 4D, R 633 (598) 678 (643) 65 1115 1500 1545 535 580 580 958 1193 1240 8 VA 5D 735 (700) 780 (745) 1165 1215 1600 1645 635 680 680 1060 1295 1 VA 5R 760 (725) 805 (770) 1190 1240 1625 1670 660 705 705 1085 1320 1365 VP 6 725 (690) 770 (735) 1155 1205 1590 1635 625 670 670 1050 1285 1330 Note) Parenthesized figures denote the weight under JIS 63K. - 14 -

Flow direction Side-mounted hand wheel Flow direction Positioner Flow direction Flow direction Positioner Positioner Side-mounted hand wheel Side-mounted hand wheel Positioner Side-mounted hand wheel Positioner Positioner Side-mounted hand wheel Flow direction Flow direction Flow direction Flow direction No. 1 (Standard type) No. 2 No. 3 No. 4 Note) 1) Note) 2) Figure 3 orientation Indicate by position number when installation other than the standard type is required. With Type PSA6R and VP actuators, the side mounted hand wheel is mounted on the same side as the positioner. Ordering information When ordering, please specify; 1) Model Number: HPC 2) Nominal size Cv value 3) Type and rating of end connections 4) Body and trim material, necessity of hardening 5) Valve and plug characteristics 6) Type of bonnet 7) Type of actuator and air to diaphragm 8) Valve action (direct or reverse) 9) 10) 11) 12) 13) 14) 15) Accessories (positioner, hand wheel, pressure regulator and etc.) Special requirement of degreasing, copper free and etc. Name of flow medium Normal flow and maximum required flow Pressure of flow medium, upstream and downstream pressure at maximum and minimum, required flow Temperature and specific gravity of flow medium Viscosity of flow medium, inclusive or exclusive of slurry - 15 -

Specifications are subject to change without notice. Advanced Automation Company 1-12-2 Kawana, Fujisawa-shi Kanagawa-ken 251-8522 Japan URL:http://www.azbil.com No part of this publication may be reproduced or duplicated without the prior written permission of. Mar. 2001 _ Y/Y Jun. 2009 (rev.1) _ Y/Y