Cover Page for Lab Report Group Portion. Head Losses in Pipes

Similar documents
Cover Page for Lab Report Group Portion. Pump Performance

Cover Page for Lab Report Group Portion. Lift on a Wing

Cover Page for Lab Report Group Portion. Drag on Spheres

MEMORIAL UNIVERSITY OF NEWFOUNDLAND Faculty of Engineering and Applied Science FLUID MECHANICS LABORATORY PIPE FRICTION

Lab #1 Pressure: Bubblers and Water Balloons CEE 331 Fall 2003

Cover Page for Lab Report Group Portion. Boundary Layer Measurements

Lab #4 Pipe Flow, Minor and Major Losses, and Walking in Osborne Reynolds Shoes CEE 331 Fall 2006

Cover Page for Lab Report Group Portion. Flow Visualization in a Water Channel

Cover Page for Lab Report Group Portion. Compressible Flow in a Converging-Diverging Nozzle

Cover Page for Lab Report Group Portion. Compressible Flow in a Converging-Diverging Nozzle

Experiment 8: Minor Losses

Lab 1: Pressure and surface tension. Bubblers, gravity and the mighty paper clip.

Exercise 2-2. Second-Order Interacting Processes EXERCISE OBJECTIVE DISCUSSION OUTLINE. The actual setup DISCUSSION

Operating Instructions

The Discussion of this exercise covers the following points:

Instruction Manual. Pipe Friction Training Panel

The Discussion of this exercise covers the following points:

INSTRUCTION MANUAL. process. Ultrasonic Flowmeter Range

Armfield Distillation Column Operation Guidelines

Pump Performance Testing

ME 333 Fluid Mechanics. Lab Session VISCOUS LOSSES IN PIPES

Pegas 4000 MF Gas Mixer InstructionManual Columbus Instruments

This portion of the piping tutorial covers control valve sizing, control valves, and the use of nodes.

1. Study the performance of a binary distillation column operated in batch mode.

Installation Operation Maintenance. Bermad Level Control Valve with Modulating Horizontal Float Pilot valve One Way Flow IOM.

Physics Experiment 17 Ideal Gas Law Qualitative Study

AC : MEASUREMENT OF HYDROGEN IN HELIUM FLOW

Water Weir Flow Controller. Introduction. Safety Precautions. Mounting the Hardware

Glove Box Installation Manual

Exercise 8. Closed-Loop Pressure Control, Proportional-Plus-Integral Mode EXERCISE OBJECTIVE

Appendix: Simplified Instructions for Operating the HP 5890 GC/FID and Air Sampling Systems

Lab 1c Isentropic Blow-down Process and Discharge Coefficient

Exercise 5-2. Bubblers EXERCISE OBJECTIVE DISCUSSION OUTLINE. Bubblers DISCUSSION. Learn to measure the level in a vessel using a bubbler.

User Manual for the Mars Calibration Bench

The Gas Laws: Boyle's Law and Charles Law

AerE 343L: Aerodynamics Laboratory II. Lab Instructions

L 100. Bubble-Tube Level System. Installation, Operation and Maintenance Instructions

UNITY 2 TM. Air Server Series 2 Operators Manual. Version 1.0. February 2008

#LZ400 LEAKALYZER. Water Loss Sensor INSTRUCTION MANUAL Country Dr. #190 St. Paul, MN

Lab. Manual. Fluid Mechanics. The Department of Civil and Architectural Engineering

Manual for continuous distillation

DNVGL-CP-0187 Edition March 2016

ONSITE PROVING OF GAS METERS. Daniel J. Rudroff WFMS Inc West Bellfort Sugar Land, Texas. Introduction

Boyle s Law. Pressure-Volume Relationship in Gases. Figure 1

product manual HM-4140, HM-4150, HM-4160 HM-4160A HM-4150 Humboldt FlexPanels

Blue River Technologies Port-A-Poly Mixer w/2.5 GPH LMI Pump And Secondary Water Dilution Line INSTALLATION AND OPERATION

Model: 43T. Bermad Pressure Relief Valve

APA software instruction manual

Constant Pressure Inlet (CCN) Operator Manual

5890II GC Standard Operating Procedure 9/2/2005

UBEC 1AT. AUTO TANK Fill System Installation, Operation, & Setup Instructions

Boyle s Law: Pressure-Volume Relationship in Gases

MEMORANDUM. Investigation of Variability of Bourdon Gauge Sets in the Chemical Engineering Transport Laboratory

In Response to a Planned Power Outage: PPMS EverCool II Shut Down and Re-start Procedure

Exhibit 4. Determination of Static Pressure Performance of the Healy Clean Air Separator (Executive Orders VR-201-N and VR-202-N)

GA-300 Gas Analyzer. Technical Note. Overview. Front Panel. iworx Systems, Inc. GA-300

Bladder Tank Installation & System Design Information

AcornVac Vacuum Plumbing Systems - Trouble Shooting Guide

Hydrostatics Physics Lab XI

Exercise 2-3. Flow Rate and Velocity EXERCISE OBJECTIVE C C C

6800 Maintenance Instruction System Flush Procedure

Rejuvenation Instructions

Installation and Operation Manual

Chromat Calibration Updated October 27th, 2017

Installation of Your SprayMaster System

GM Series Dual-Block Multi-Function Gas Control Valves

6900 Maintenance Instruction System Flush

KIV-SACS Safe automatic calibration system:

Measuring Mass and Volume

TANK MANAGER FOR TWO TANKS OPERATING MANUAL. 10/31/11 C-More T6C L color touch panel

STANDARD OPERATING PROCEDURES. Andersen Instruments Federal Reference Method (FRM) Ambient Particulate (PM 10 /PM 2.

Mass Spec will not Autotune

PROPORTIONING VALVE. Model 150 INSTRUCTION MANUAL. March 2017 IMS Company Stafford Road

BAPI Pressure Line of Products - FAQs

HEATEC TEC-NOTE. Setting Siemens Pressure Transmitter. Used on Heatec Vertical Asphalt Tanks. Publication No , Revised

UsER manual for Watersens ph -REDOX

CHEMICAL ENGINEERING LABORATORY CHEG 239W. Control of a Steam-Heated Mixing Tank with a Pneumatic Process Controller

DESIGN DATA A WET PIPE BLADDER TANK FOAM/WATER SYSTEM WITH HYDRAULICALLY ACTUATED DELUGE CONCENTRATE CONTROL VALVE

AC : A LABORATORY EXERCISE TO DEMONSTRATE HOW TO EXPERIMENTALLY DETERMINE THE OPERATING POINT FOR A FAN

Exercise 4-2. Centrifugal Pumps EXERCISE OBJECTIVE DISCUSSION OUTLINE DISCUSSION. Pumps

CENTER PIVOT EVALUATION AND DESIGN

Endo-Flush Order # ZUTR30004 OPERATION MANUAL. Zutron Medical, LLC W 98 th St #40-27 Lenexa, KS Phone Fax

A centrifugal pump consists of an impeller attached to and rotating with the shaft and a casing that encloses the impeller.

256 Pneumatic Pressure Indicator

Vapor Sorption Analyzer

The Discussion of this exercise covers the following points: Pumps Basic operation of a liquid pump Types of liquid pumps The centrifugal pump.

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

SOLUBILITY OF A SOLID IN WATER

Model 130M Pneumatic Controller

EXPERIMENT 1 BASIC LABORATORY TECHNIQUES AND TREATMENT OF DATA MEASUREMENTS

ACV-10 Automatic Control Valve

AX5000 Operational Manual

Superconducting Susceptometer (MPMS-5S) Quantum Design Room 296 (MPMS)

Operating Instructions

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

Experiment P18: Buoyant Force (Force Sensor)

Operating Instructions

Flow in a shock tube

TR Electronic Pressure Regulator. User s Manual

Title: Standard Operating Procedure for Elemental and Organic Carbon (EC and OC) using Non-Dispersive Infrared Detection (NDIR)

Transcription:

Cover Page for Lab Report Group Portion Head Losses in Pipes Prepared by Professor J. M. Cimbala, Penn State University Latest revision: 02 February 2012 Name 1: Name 2: Name 3: [Name 4: ] Date: Section number: ME 325. Group letter: (A, B,...) Score (For instructor or TA use only): Lab experiment and results, plots, tables, etc. - Procedure portion Discussion Neatness & grammar TOTAL / 45 / 15 / 10 / 70 Comments (For instructor or TA use only):

Procedure and Presentations of Results A. The Test Rig and Its Operation A continuous pipe flow rig is used in this lab experiment, as sketched in Figure 2. The flow is pumped from the water tank as shown, and makes a 180 o turn so that the flow exits back into the water tank. Quick connects are used so that various test specimens, such as long straight sections of pipe, or sections of pipe with various minor loss devices, can be easily interchanged. Each test specimen has two static pressure taps installed so that the head loss between the pressure taps can be measured directly, using a differential pressure transducer. Quick connect pressure line couplings are used to connect the pressure taps to the pressure transducers, so that the pressure lines can be connected quickly and easily as well. The volume flow rate through the test rig is measured by a magnetic resonance flow meter with a digital readout. Quick connects Magnetic resonance flow meter L Flow control valve Pressure tap to high port of Head pressure transducer Test specimen Pressure tap to low port of Head pressure transducer Quick connect Water tank Flow pump Pump Figure 2. Schematic diagram of the pipe flow test rig. (3) 1. There is a correct and an incorrect way to install the pipe test specimens. Circle the correct way, and give a brief explanation for your choice: High pressure tap Test specimen L Low pressure tap Explanation: High pressure tap Low pressure tap Test specimen L (6) 2. Standard pipe sizes are not always what they claim to be (actual inner diameter nominal inner diameter). For example, the inner diameter of standard 3/4-inch galvanized iron pipe is not exactly 0.750 inches ID. The diameters are listed in Table 1 below. Measure L for each pipe specimen (L is defined here as the distance between pressure taps the length of pipe through which the head loss is to be measured). Finally, measure the distance from the beginning of the pipe specimen to the first (high pressure) pressure tap. This is the entrance length of pipe, L e, available, which is available for the flow to become fully developed. Later on, you will be asked to calculate the required entrance length, L e, required, for each pipe and for each flow condition for comparison. Record these values on Table 1. Table 1. Measured pipe diameter, length, and available entrance length. Pipe section Measured inner diameter (inches) ½-inch copper 0.545 ¾-inch copper 0.789 ¾-inch galvanized 0.831 ½-inch PVC 0.610 1-inch PVC 1.047 1.5-inch PVC 1.699 Length L (inches) Available entrance length L e, available (inches) 3. Install one of the test specimens into the pipe flow rig.

B. Calibration of the Electronic Pressure Transducer associated with Head Loss To simplify the task of data collection, the major head loss h major through the test specimen is measured electronically by the computer data acquisition system. The Validyne electronic differential pressure transducer marked Head consists of a thin stainless steel diaphragm within a chamber. Each side of the chamber has a port, which will be connected to one of the pressure taps. Specifically, the low pressure side of the diaphragm will be connected to the static pressure tap at the downstream end of the test specimen, while the high pressure side will be connected to the static pressure tap at the upstream end. When the flow loop is running, providing a head loss through the test specimen, the larger pressure upstream causes the diaphragm inside the pressure transducer to deflect slightly. This deflection is measured electronically and is converted into a DC voltage, which is displayed by the Validyne display unit. This voltage is also sent to the computer s Analog-to-Digital (A/D) converter for processing. As presently set up, the A/D converter can read voltages in the range from -5 to 5 volts. However, the Validyne display unit output is an analog voltage that ranges from only -2 to 2 volts. The display unit actually displays the voltage times a factor of 100. For example, a reading of 158 on the display unit corresponds to an analog voltage output of 1.58 volts. A reading of 200 units corresponds to the maximum 2.00 volts of the unit. Thus, to avoid clipping of the signal, never exceed 200 units on the Head display unit while acquiring data with the computer. Prior to data collection, the differential pressure transducer must be calibrated to measure the proper head, and to set the span such that nearly the full range of the display unit is utilized (for highest accuracy). The maximum head loss for any pipe specimen in this lab will be limited to 200 inches of water column, and the unit will be calibrated such that 100 inches of water corresponds to 100 display units, or 1.00 volts. There is a calibration stand in the lab, which is set up to provide 48.0 inches of water head as a calibration point. In this lab experiment, therefore, the head transducer will be calibrated such that 0.480 volts (48.0 display units) corresponds to 48.0 inches of water head. (48 inches per 0.48 volts is the same as 100 inches per 1.0 volts.) To calibrate the transducer, follow these steps: 1. Place both stainless steel calibration containers on the top shelf of the calibration stand, side by side. 2. Add water to the calibration containers (if necessary) until they are about 3/4 full (and approximately equal in level). 3. Connect the clear tubing from the tanks to the low pressure and high pressure inlets of the pressure transducer. 4. This step is critical! Any trapped air bubbles in any of the lines will lead to severe calibration errors. If bubbles are visible in the manometer tubes, gently tap the tubes near the bubbles to try to move the bubbles out the tops of the tubes. If the bubbles persist, empty the stainless steel containers into the tank. Then drain the manometer tubes into a bucket using the quick disconnects at the bottoms of the manometer tubes. Reconnect the manometer tube fittings. Now refill the stainless steel containers as in step 2. If the manometer tubes still contain persistent bubbles, ask your TA for assistance. Now open both bleed valves on top of the differential pressure transducer to bleed any air bubbles trapped in the lines or in the transducer chamber itself. Note: These valves are open when the switch handle is vertical, and are closed when the handle is horizontal. Bleed all of the air bubbles out of both lines; visually inspect the lines to be sure they are free of bubbles. If you are unable to get rid of the air bubbles, get help from your Instructor or TA before proceeding. When all air bubbles have been removed, close all thumb valves, and close both transducer bleed valves. You are now ready to calibrate. 5. Add water to (or drain water from, using the blue thumb wheel pincher on the drain lines) one of the calibration containers if necessary until the water in both containers is at the same level (approximately 68 inches on the manometer scale, which has an arbitrary datum plane). 6. At this point, there is zero pressure difference across the pressure transducer. If necessary, adjust the ZERO potentiometer on the Head Validyne display unit until the reading is zero. 7. Carefully move the left (low pressure) calibration container from the high shelf to the low shelf. If not done slowly, new bubbles may form in the manometer tube take your time here or you may have to start over. 8. Add water to (or drain water from) the low pressure calibration container if necessary until the difference in height between the two manometer tubes is exactly 48.0 inches (as measured by the two manometer tubes and ruler). 9. At this point, the pressure difference across the pressure transducer is 48.0 inches. Adjust the SPAN potentiometer on the pressure transducer display unit (if necessary) until the reading is 48.0 units. As discussed above, this calibrates the transducer to 48.0 inches of water head per 0.48 volts (100 units to 100 inches of water). 10. Now that the span has been set, the zero may have shifted slightly. Slowly return the low pressure calibration container to the upper shelf. The Validyne display unit should return to zero. Repeat Steps 5 through 9 if necessary until both the zero setting and the pressurized setting are correct. 11. The differential pressure transducer is now properly calibrated. (A linear transducer response is assumed, and is quite accurate.) Return the low pressure calibration tank to the upper shelf. 12. Disconnect both clear tubing lines from the pressure transducer using the quick connects, and close the thumb valves on these lines so that the water in the calibration tanks does not flow out.

13. Using the blue quick connects, and working over a bucket to avoid spillage, connect the high pressure port of the pressure transducer to the pressure tap at the upstream end of the pipe. Connect the low pressure port of the pressure transducer to the pressure tap at the downstream end of the pipe. C. Data Collection 1. Before beginning data collection, confirm that the flow meter is properly configured to read L/min. If the display currently does not read a volume flow rate, try the down or up arrow to reach the volume flow rate screen. Note that the screen on the flow meter does not need to be touched, but simply holding your finger in front of the correct arrow will select it. If the units are not correct (it reads m/s or gal/min), hit the down arrow to select Basic Settings, the right arrow to select Units, and the down arrow again to select L/min, and then hit enter three times to return to the main screen. The enter button has a small letter E on it, and is in the upper left hand corner of the flow meter screen. If the display still is not reading correctly, get help from your instructor or TA. 2. Add water if necessary to the water tank so that the flow pump is fully submerged. Verify that one of the pipe test specimens is properly installed, and the flow control valve is partially open. If no pipe test specimen is in place, ask your Instructor or TA for assistance in installing it the first time. It should not be necessary to use wrenches or other tools to install the pipe specimen. Turn on the flow pump and make sure there are no significant leaks through any of the connections (some dripping is okay). If leaks persist, call your instructor or TA for assistance. 3. Bleed the flow system of all air bubbles every time you change pipe specimens or turn off the flow pump. Note: This is a very critical step! Air bubbles in any of the pressure lines will lead to gross errors in your data. To bleed the air bubbles properly, close the flow control valve about 95% of the way (not fully closed because this will burn out the flow pump). This lowers the flow rate to a trickle, and increases the head in all the tubes, which aids in purging out any trapped air bubbles in the lines. Open both bleed valves above the pressure transducer. Tap on the tubing quick connects to release trapped air bubbles, and watch them until they move all the way through the pressure line, through the pressure transducer, and out the bleed valve. Close both bleed valves. 4. Start program PipeFlowMeasure from the computer s desktop or Start Menu. In the User Control window, Enter Parameters. In the User Entries window that pops up, Save Results File, and enter a file name for your data set. For uniqueness of your data file, name your file something indicative of your group and of the test specimen, such as Smith_groupC_copper_75.txt, where Smith is the name of one of the group members, and the 3/4-inch copper pipe is being used in this example. Enter the length of the pipe between pressure taps, the inner diameter of the pipe, and the calibration constant. Unless calibrated otherwise, the constant should be 1.0 V = 100.0 inches of water head, since the Head transducer is calibrated at 48.0 units (0.480 V) per 48.0 inches of water head. OK. (3) 5. Practice measuring the volume flow rate manually (with a graduated cylinder or bucket and stopwatch) at some arbitrary (low) flow rate. Depending on the flow rate, it may take some practice, and you may need to try using different containers to measure the flow volume. When you are confident that you can measure the flow rate properly, enter the values in the spaces below: Manual volume flow rate calculation: Measured volume: ml Measured time: s Calculated flow rate: L/min Compare the manually measured flow rate to the display of the flow meter. If the difference is more than a few percent, consult your instructor or TA before proceeding. If the manual reading and the flow meter reading are close, you can trust the flow meter from now on, and there is no need to measure the flow rate manually anymore. 6. In the User Control window, Set Flowrate. The computer will prompt you to enter the measured volume flow rate in liters per minute. Enter the flow rate reading from the flow meter display. OK to start acquiring data for your first data point. (3) 7. Compare the head loss on the Validyne display to that recorded by the computer to ensure that this reading is being acquired properly. (Recall that one unit on the Validyne display represents one inch of water head.) Validyne display: Validyne head reading: Manual head loss calculation: units inches of water h major Computer-acquired head loss: inches of water

If the computer-acquired head loss is significantly different than what you read manually, something is not set correctly ask your instructor or TA for assistance. 8. Take data with this test specimen at several flow rates, after adjusting the volume flow rate with the control valve. For each data point, enter the volume flow rate reading from the magnetic flow meter. The head loss reading is recorded directly by the data acquisition system. Cycle up and down from a trickle to maximum possible flow rate. Don t worry about the order of your data collection the order is irrelevant. Keep an eye on the Validyne display unit. Do not take data if the reading exceeds 200 units (2.00 volts), or the signal will be clipped. When finished, exit the program. The data should automatically be stored onto the file you created previously. Be sure to take enough data points to generate a smooth, repeatable curve. Some duplication is appropriate to test for repeatability. (10) 9. Install a different pipe test specimen. To interchange test specimens, turn off the flow pump, disconnect the blue tubing quick connects from the static pressure taps. Be sure there is a bucket under the pipe quick connect at the upstream end of the pipe to catch water that will leak out when this connection is broken. Carefully disconnect the pipe quick connect at the downstream (valve) end of the pipe. Then disconnect the pipe quick connect at the upstream end of the pipe and remove the pipe test specimen. Incline it slightly so that any remaining water in the pipe can drain into the water tank. Install the new test specimen by reversing this procedure. The pipe quick connects should require only hand tightening to be fairly leak free. Bleed the flow system of all air bubbles, restart the program PipeFlow Measure, and repeat Step 8 for the new test specimen. Repeat for all the pipe specimens. Be sure to select a different file name for each test specimen, or else you will overwrite (and lose) your previous data. Using Excel or Notepad, make a printout of the data file for each case, making sure each table is properly titled and labeled. See Tables. 10. Finally, when finished with the data acquisition, turn off the flow pump. You may leave the water in the tank, and you may leave the last test specimen in the rig. Restore all other test specimens to their original locations. Be sure to copy all your calibration and data files onto the computer s desktop or onto a portable media device before you leave. D. Presentation of the Data (10) 1. For each test specimen, and for each flow rate, calculate the Darcy friction factor, f, and the required entrance length, L e, required. (This is most easily done with a spreadsheet.) Prepare a table of all the experimental results for each pipe section. The table should include volume flow rate, average velocity, Reynolds number, head loss, Darcy friction factor, required entrance length, and available entrance length for each case. Label and attach each table to this report. Show some sample calculations in the space below: See Tables. Sample Calculations: (10) 2. Prepare a plot of friction factor f versus Reynolds number for the pipes tested here. In other words, prepare your own limited version of the Moody chart. For comparison, include on your plot the published data for a smooth pipe. These data can be manually picked off the Moody chart, or the Colebrook equation can be used to obtain f versus Re d for a smooth pipe. Put data from all the pipes on the same plot, being sure to identify the pipes with a legend. Label and attach your figure to this report. See Figure.

Discussion (5) 1. How does your Moody chart, (your plot of friction factor versus Re d ) compare with the published Moody chart? (5) 2. Are your results more accurate at low flow rates, or at high flow rates? Why? (5) 3. Discuss possible sources of error in this lab experiment. How might the lab be improved?