AASHTU DESIGN CRITcKIA APPLIED TO HYURxULIC BASCULE BRIDGES. Yaskin, P.E. B.Y.

Similar documents
Exercise 2-3. Flow Rate and Velocity EXERCISE OBJECTIVE C C C

TECHNICAL BENEFITS OF CJS / RAISE HSP. Technical Advantages

Proper Pump Installation Practices

PLD 03 T A CASAPPA S.p.A.

VPPL VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS FOR INTERMEDIATE PRESSURE SERIES 10

Air Amplifiers & SYSTEMS

Model 7989T Steel Pipe Squeezer Sch. 40 & Sch. 80. Operations Manual

Fixed Displacement Plug-In Motor A2FE

Vibration and Pulsation Analysis and Solutions

Hydro-Mech Bridge Plug

Item 404 Driving Piling

Copyright, 2005 GPM Hydraulic Consulting, Inc.

Lecture 19 PRESSURE-CONTROL VALVES [CONTINUED]

310 SERIES TILT-TO-LOAD ROTATOR. The Specialist In Drum Handling Equipment

WORKHOLDING APPLICATION BOOKLET

Contents. Catalog HY /US Load and Motor Control Valves SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. LPM/GPM BAR/PSI

Displacement 12, , Maximum flow rate (at 1450 rpm) bar.

Mining scalers are used in. Designing a stable suspension. F l u i d P o w e r. Demanding application requires unique engineering approach.

Standard Operating and Maintenance Instructions for Pumping System Model PS-150

LECTURE 20 FLOW CONTROL VAVLES SELF EVALUATION QUESTIONS AND ANSWERS

FLUID POWER FLUID POWER EQUIPMENT TUTORIAL OTHER FLUID POWER VALVES. This work covers part of outcome 2 of the Edexcel standard module:

DIVERLESS SUBSEA HOT TAPPING OF PRODUCTION PIPELINES

Pressure on Demand. Air Pressure Amplifiers

Flow divider designs MTL

09 - Choosing /sizing a cylinder and valve

Introduction to Pneumatics

TECHNICAL DATA. Q = C v P S

Standard Operating and Maintenance Instructions for Pumping System Model PS-90

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Q = C v P S

LINDGREN-PITMAN, INC. LS-3 / LS-4 Line Setter

94270 Vapor Guard Tank Blanketing Valve Vapor Guard Tank Blanketing Valve What is Tank Blanketing? Features How does it work?

Fixed Displacement Motor A4FM

E 328 E 498 Tank top mounting Connection up to G1½ and SAE 2 Nominal flow rate up to 600 l/min

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Q = C v P S

Dual displacement motor A10VM Plug-in dual displacement motor A10VE for open and closed circuit applications

TECHNICAL DATA. Q = C v P S

INDIAN INSTITUTE OF TECHNOLOGY KHARAGPUR NPTEL ONLINE CERTIFICATION COURSE. On Industrial Automation and Control

HEAVY DUTY PNEUMATIC

Robot Arm Challenge Answer Key

Lesson 6: Flow Control Valves

BACK PRESSURE / SUSTAINING

Technical Data Sheet TI-F50 Locking Units series KFH

Introduction. Part one: Identify the Hydraulic Trainer Components

E 328 E 498 Tank top mounting Connection up to G1½ / -24 SAE and SAE 2 Nominal flow rate up to 600 l/min / gpm

BACK PRESSURE / SUSTAINING

Variable Displacement Double Pump A20VO. Series 1, for open circuits Axial piston - swashplate design, Back to back - design

TECHNICAL DATA SINGLE INTERLOCKED PREACTION SYSTEM WITH PNEUMATIC RELEASE

TECHNICAL DATA OBSOLETE

3 1 PRESSURE. This is illustrated in Fig. 3 3.

STANDARD FOR CONTROL VALVE SEAT LEAKAGE

Unit 24: Applications of Pneumatics and Hydraulics

Hydraulic comparison test pump Models CPP1000-X, CPP1600-X

XDF BURNERS DUAL FUEL EXCESS AIR BURNER FEATURES DESCRIPTION EXCESS AIR OPERATION

SIZING THE WELL-X-TROL

The Shand & Jurs Model Vapor Guard Tank Blanketing Valve

Index Table. Model 794. Installation, Operating and Maintenance Instructions

Basic Pneumatics. Module 8: Pressure control valves. Academic Services PREPARED BY. April 2012

HANDBOOK. Squeeze Off Unit SOU 400. Please refer any queries to:

Document How to Set Single Stage Press Pressures

Gerald D. Anderson. Education Technical Specialist

[You may download this article at: ]

Plant, components and devices for very high and high pressures (7000 bar and over)

Series ZFC. Air Suction Filter In-line Type with One-touch Fittings

Sauer Danfoss Series 90 Hydraulic Axial Piston Pump

Rate of Flow Valve Series 120

DI-DRO ADVANCED FORMING SYSTEMS

Hydraulic Reliability & Preventive Maintenance Report

Hatch cover securing and tightness

MODEL 200 KNIFE GATE VALVES INSTALLATION & MAINTENANCE MANUAL

Controllers DR, DP, FR and DFR

HANDBOOK. Squeeze Off Unit SOU 250. Please refer any queries to:

Load Controls Screw In Cartridge Valves Pressures to 350 bar (5000 psi) Flows to 190 l/min (50 USgpm)

Full Range Pressure Compensating Variable Flow Control

TECHNICAL DATA. System water supply pressure enters the priming chamber of the deluge valve (A.1) through the 1/4 (8 mm) priming line, which

The Enerpac Lightweight Aluminum Cylinders

Fixed Displacement Pump KFA for commercial vehicles in open circuits

IAPMO GUIDE CRITERIA FOR BALL VALVES IAPMO IGC PURPOSE

FLUID POWER FLUID POWER EQUIPMENT TUTORIAL ACCUMULATORS. This work covers part of outcome 2 of the Edexcel standard module:

ARKANSAS TECH UNIVERSITY FACILITIES MANAGEMENT HEALTH AND SAFETY MANUAL (LOCKOUT/TAGOUT) 30.0

Moving Fluids Concept and Theory

Air Operated Hydraulic Pumping Systems to 50,000 psi

The Time Has Come For Coiled Rod. Reprinted from Well Servicing magazine

ACCUMULATOR OPERATING & MAINTENANCE INSTRUCTIONS

then the work done is, if the force and the displacement are in opposite directions, then the work done is.

COMPARING PLUG & SEAT REGULATORS & CONTROL VALVES. Lamar Jones. Equipment Controls Company 4555 South Berkeley Lake Road Norcross, GA 30071

Modulating Valves for Atmospheric, Infrared, and Direct Fired Burners

Development of a High Pressure, Oil Free, Rolling Piston Compressor

Phuel Portable Control Units

Vickers. Filters. Reservoir Vent Filters. Spin-on Air Filters & Adaptors. Rev. 3/98

ANTI SHOCK RELIEF VALVE

Displacement. from 2 up to 6 sections balanced, unbalanced from 0.8 to 31 ccm FLOW DIVIDERS

CHAPTER 9 PROPELLERS

Restoring Fluid Flow in Tubing Strings

DuPage County Environmental, Safety, Health & Property Loss Control Program Hazardous Energy Control (Lockout/Tagout)

ACCURACY, PERFORMANCE, AND HANDLING OF OIL-FILLED DIGIQUARTZ PRESSURE INSTRUMENTATION

Model 130M Pneumatic Controller

Safe hydraulics for hydroforming presses. more finished product to be created from less raw material.

UBEC 1AT. AUTO TANK Fill System Installation, Operation, & Setup Instructions

Transcription:

AASHTU DESIGN CRITcKIA APPLIED TO HYURxULIC BASCULE BRIDGES by B.Y. Yaskin, P.E. The code we are referencing is the Standard Specification for movable highway bridges published 1978, by the American Association of State Highway and Transportation Officials. It should be noted, as it is in tne introduction to the specifications, that much of the material included in this specification was adopted from the American Railway Engineers Association Specifications that apply to movable bridges. Those specifications were prepared and apply to railway bridges. The AgEA expresses no opinion as to their suitability for highway bridges and cannot be responsible for any hignway applications thereof that may be adopted. It is also stated that the AASHTU Movable Bridge Specifications be used in the conjunction with the standard specifications for highway bridges. As an interesting note, we nave two volumes of a text entitled, "Movable Bridges" in our company library. Volume I deals with structure, Volume I1 deals with machinery. The author of these texts is Otis Ellis Hovey, BSCE, published by John Wiley 6 Sons, in tne year 1927. Appendix A of Volumn I1 is entitled "Specifications for Movable Bridges" by O.E. Hovey, published in 1925. Much of tnat specification, as it applies to power requirements and macninery design, od~l as it may seem, is identical to the 1978 xashto specification. It has apparently stood the test of time and is proven to be a more than suitable guide in the design of bascule bridges. Tile basic intent of this paper is to discuss the specifications as they apply specifically to bascule bridges. The current edition of AA5HTU contains very little reference to hydraulics but certain sections can be utilized even if the reference is to machinery. Tile AASHTO specifications start out with Division I entitled, "General Provision" and is specifically written as a guide for contractors, but it woiild be well worth the time of any designer to be aware of its requirements. Witn respect to hydraulics, Article 1.1.4 "Time of Opening" defines the meaning of normal time of operation. The actual time for bridge openings is not specifically spelled out in the specification. As a general practice, between 60 and 75 seconds is consiclered the normal time of opening and closing. Article 1.1.6 bfachinery/hydraulics Design spells out, among other things, various items to be considered as conditions of loading.

A) The effect of acceleration or retardation generally considered to be between 5 and 15 seconds. The obvious force here is overcoming inertia. B) The effect of frictional resistance which generally consists of the frictional resistance in the main trunnion bearing, the efticiency of the hydraulic system which should account for pressure losses in lines, fittings, and components. C) Any unoalanced condition of the bridge. It is generally accepted that some unbalance be required for bascule bridges. This unbalance is normally to make the bridge nose heavy, thus requiring somewhat less force for closing and to provide a positive downward force at the live load shoe. For hydraulic cylinder this may also help even-out operating pessure when co~riing down since the rod end of the piston yields a smaller area upon which to develop the total operatiunal force. D) Wind loads for which three load conditions are generally considered. A 2 1/2 pound wind used for the selection of power and design of hydraulic system to operate the bridge In tne normal time frame, 60-75 seconds. A 10 pound wind used for selection of power and design of hydraulic system to operate the bridge in twice the normal time, 120-150 seconds, and a 20 pound wind force used to establish maximum hydraulic pressure for holding the bridge in any position. Division I1 of this specification is entitled, "Design" and is divided into two groups, structural and machinery. Of interest in the structural section is Article 2.1.11 entitled, "Impact". Hydraulic cylinders are supported by some part of the structure and will be affected by the operating forces. This section requires tnat stresses in structural parts caused by the machinery/hydraulic or by forces applied by moving or stopping the span, shall be increased 100% as an allowance for impact. Article 2.1.12, "Fatigue", refers the designer to the basic design criteria and allowable fatigue stresses as given by the current edition of AASHTO Standard Specifications for Highway Bridges. Article 2.1.14 "Hydraulic Cylinder Connection". The stresses on the structural connecrion to the cyliners shall be based on a cylinder pressure of 150 percent of the setting of the pressure-relief valve controlling the maximum pressure available at the cylinder. Continuing on into the Machinery Design section - the designers first series of steps is to determine tne location and size of hydraulic cylinders and the following steps would thus be necessary:

1) Establish normal time for opening - 60-75 seconds. 2) Establish the Maximum angle of opening generally 74 to 77 degrees. 3) Positioning of hyraulic cylinders. Obviously the first choice would be to locate hydraulic cylinders under main girders. This would not be the only location available and in the case of bridge renovation where a hydraulic system were to replace a machinery system, other locations may prove to be more suitable. The connection of the rod eye at tne end of the piston rod via pillow blocks (bearings) to the main girder or structure should be located well below tne trunnion and as far forward of the trunnion as is possible. The bottom surface of the bottom flange of the main girder provides the designer with both these features. The basic object is to create a situation where the moment arm, being the distance between the piston rod and the center of rotation (trunnion), is maintained at a maximum throughout the opening and closing process. This, in effect, will produce the minimal amount of operating force needed during the entire opening process. Cylinders can be supported on the machinery platform at the end with a clevis type device or at intermediate points between the bottom and the top of the cylinder. In effect, one consideration in determining the ultiitiate length of the cylinder would be the stability of the cyli~lder and piston rod when fully extended. The shorter the distance between the rod eye and the point of support of the cylinder which would result in an overall shorter cylinder. In essence, the cylinder is made longer in order to leave the piston deeper within the cylinder when the piston rod is fully extended. The term for this is "stop-tube distance", a distance added to the length of stroke required to fully actuate the bridge. It has been our finding that a center mounted trunnion cylinder provides the best features for design. Supporting the cylinder too close to the top also results in the need for a very accurate alignment between the vertical axis of the main girder and the horizontal positioning of the cylinders. 4) At this point one should calculate or estimate the various individual load considerations as mentioned earlier, such as overcoming inertia, resistance in the trunnion bearing, efficiency loss in the hydraulic system, unbalanced moments due to unbalanced load conditions, and the loads created by the 2 1/2 pound wind, the 10 pound wind and the 20 pound wind.

Article 2.5.3, "Power Requirements and Machinery (Hydraulic) uesign" established specific load conditions and combinations for whicu tne hydraulic system shall be proportioned and power provided. Condition A is tne combination of loads for normal time of opening, the 60-75 second time frame. For bascule bridges the load combinations include the effects of frictional resistance, inertia, unbalanced load conditions and a wind load of 2 1/2 pounds per square foot acting normal to the floor with the bridge in any position, for open decked grid floor bridges the floor area may be reduced by 15%. Condition B is the combination of loads for whicn an extended time of operation is allowed, specifically 1 1/2 times the nornal time. This combination requires an additional 2 1/2 pounds per square foot for ice loading be applied. In addition to those loads specified under condition A above. Obviously, this load condition need only be explored where ice is likely to be encountered. Condition C, again allowing for an extended time of operation, specifically twice the normal time, requires the following combination of loads: Frictional resistance, inertia, unbalanced load conditions, and a wind load of 10 pounds per square foot on any vertical projection of the open bridge and an ice load of 2 1/2 pounds per square foot. Again, the ice loading need only be applied in areas where ice is anticipated. When calculating the actual time of operation, at no time should the wind loads be less than 2 1/2 pounds acting normal to the bridge as compared to the 10 pounds per square foot acting on the vertical projection of the open bridge. A brief discussion and consideration of electric motors and pumps is important at this point. In most hydraulic applications a somewhat higher speed motor is generally provided than that used for the machinery design systems. It has been our practice to select an 1800 rpm motor. The hydraulic pump that we intend to use will require horsepower control. With this pump the monitoring of horsepower in terms of flow (gallons per minute) and pressure will be provided. With this type of pump we will obtain automatic stroking or ramping of the pump to insure that the combination of flow and pressure generated by the system will provide a uniform horsepower output. Thus the motor is generally brought up to speed prior to energizing or stroking the pumps. With this motor pump combination the system has the ability to operate under a variety of load combinations and the effect would be to regulate flow thus extending the time of operation. This feature is a perfect match for the AASHTO loading combinations in which, as the loads are increased, the times for operation are extended.. The following series of steps are suggested in sizing cylinders and selecting power:

5) Would first require the calculation of the forces generated by each of the three load conditions, A, B, and C. Generally each lift consists of two main girders and it is therefore implied tiiat a miniurn of 1 cylinder be required under eacll main girder. It has been our practice on the somewhat larger bridges, that two cylinders be located under each main girder, or a total of 4 cylinders per leaf. This provides the designer and the owner with the ability, during repair and servicing of cylinders, to remove one or even two cylinders and still have the capability of bridge operation under normal loading conditions. We have generally found that load condition C will dictate the number of cylinders or size of cylinders that must be provided and by reviewing tne operating pressures developed for load condition A when two cylinders have been removed from the system will find that operating pressures are within safe limits. b) Determine the total operating force generated by condition A based on normal time of operation. This should be done for both the opening procedure and for the closing procedure by calculating the surface area of the piston for all cylinders and dlviding that into the opening force generated one can determine the operating pressure required, and siu~ildrly calculating the surface area on the rod side of tne cyllnder and dividing that into the force required to close the leaf will generate the operating pressure that results. Generally operating pressures for normal time of operation should be around 500-600 psi. 7) Determine operating force, and tile pressures for condition B with an extended time of 1 1 /2 tne normal time in a similar fashion to 6 above, a pressure of approximately 1000 psi would be appropriate. 8) Determine operating force, and the pressures for condition C witn an extended time of twice the normal time in a simlar fashion to b above, a pressure in the range of 1500 to 2000 psi. 9) The next condition of consideration is the ability of the cylinders to hold the bridge in the fully open position for the 20 pound wind force. Under this condition the maximum pressure of between 2500 and 3000 psi would be appropriate. 10) Having calculated the various combinations of loads and cylinder pressures and thus determined the appropriate number and size of cylinders, and having positioned them, our next step would be to determine stroke length and verify the time of operation for the various load conditions. Since loads and moment arms vary as the bridge

is opened and closed, the designer must calculate these factors based on small increments of opening. We have found the use of a computer to be very beneficial in making the calculation since the computer can perform such calculations for eacli degree of opening in a very short time. This would allow tne designer to make the most optimum selection of cylinder size arid horsepower required. With the proper program the designer could input leaf dimensions, geometric locat ions of trunriion, connection points of the cylinders, number of cylinders, size of cylinders, size of the piston rod, angle of opening under various loading conditions, his estimate of horsepower required, the efficiency of the systell1 and time for acceleration. Because of the rotation of the leaf the moment arm between the center of rotation and tne piston rod vary with each degree of opening and since the 10 pound wind load is applied to the vertical projection of the leaf, the forces applied to the cylinder vary with each moment of opening. With the computer program the designer would analyze in one degree increments, all conditions of loading, calculate the length of stroke, moment arm, forces required to push tne leaf up and pull the leaf down, pressures encountered, and time required to move the leaf through each degree of opening. Once the hydraulic cylinders, motor, pumps have been established, various other components must be selected. In order to utilize the hydraulic cylinders as an effective brake in which the leaf can be held in any position, check valves are necessary and should be located as close to cylinder ports as is practical. In our case, pilot actuated check valves are necessary so that when pressure is applied to the cylinder at one port, the check valve at the other end is automatically opened. Thus whenever the power or pumps are shut-off the crleck valves automatically close locking fluid in cylinders and therefore results in holding tile bridge in its current position. Relief valves are so necessary that operating pressures do not exceed design liioitations. As we discussed, the maximum operating pressure for load condition C would be in the range of 1500 to LUUU psi and we should therefore have at an appropriate location, a relief valve which is set to the maximum operating pressure expected, and since the cylinders are to be utilized as brakes with the capability of withstanding the Zu pound holding force, a second set of relief valves would be necessary which would have a pressure setting of somewhere between 25UO and 3000 psi. The selection of other components such as counter balance valves and four-way directional valves, would be selected based on the

volume of flow. Hydraulic tanks should be sufficiently large enough to hold between 4 and 5 times the required volume of fluid to operate the bridge during one cycle. This large volume of fluid is primarily used to dissipate heat, but certainly insures ample supply of fluid. Where hydraulic systems are anticipated to be used a numerous number of times in quick succession and it is likely that an excessive heat build-up can be anticipated the need for a heat exchange should be provided. On the other hand, it may be necessary to provide a heating element to bring oil temperatures up to operating levels. This is generally necessary when hyraulic systems are first used on cold mornings or even continue to be used on cold days. Proper filtration of hydraulic fluid is probably the most important item to be considered. The size of filtration and the location of filters is important. Fluid should be filtered just prior to returning to the tank. Fluid should be filtered prior to entering pumps to eliminate contaminates that might damage tne pumps unless pump designs are capable of handling contaminants without damaging the pumps, otherwise filters should be used just after pumps so as to prevent contamination of hydraulic components and cylinders.