Vickers. Filters. Reservoir Vent Filters. Spin-on Air Filters & Adaptors. Rev. 3/98
|
|
- Homer Stephens
- 6 years ago
- Views:
Transcription
1 Vickers Filters Reservoir Vent Filters Spin-on Air Filters & Adaptors Rev. 3/98 73
2 Introduction Prevent Airborne Ingression A key element of contamination control is reservoir vent filtration. Reservoir vents are a common source of both water and particulate contamination from the atmosphere surrounding a hydraulic system. Fluid contamination can increase: Equipment wear Cause corrosion Reduce fluid performance and life Hydraulic components have become more complex and operate at higher pressures, flows and temperatures thus making fluid cleanliness a key to longer component life and system reliability. Vickers reservoir vent breathers make it easier to attain higher cleanliness levels, and can extend fluid filter life in the system. Vickers Offers Hi-Tech Options Vickers recognizes the variety of atmospheric conditions which hydraulic systems encounter, so we offer a complete line of vent filters to prevent airborne contamination. Requirement H2O-Gate DIRT-Gate V211 V191 Visual Indication* Particle Control Water/Moisture Control Corrosion Resistant Housing * For systems where a visual indicator cannot be seen for inspection and subsequent action, Vickers recommends service for the vent filter after 5 hours of machine operation. Contents H 2 O-Gate Model Code & Installation H 2 O-Gate Pressure Drop DIRT-Gate Model Code & Installation DIRT-Gate Pressure Drop V211 and V191 Spin-on Elements Spin-on Vent Filter Adaptors Bayonet Adaptors Bayonet Adaptors Pressure Drop System Sampling Frequency Chart
3 H 2 O-Gate Element Model Code BR11 Specifications Housing Material - ABS Plastic Temperatures - Up to 121 C (25 F) Efficiency - 99% at 3 micron Features & Benefits Rugged ABS plastic housing can be exposed to temperatures as high as 121 C (25 F), and is corrosion resistant. Visual mechanical indicator, which triggers at P,7 bar (1 psid) (during exhalation). Easy installation. Lightweight design requires only hand tightening. Low pressure drop across filter media reduces stress on reservoir and system components. Reversible flow-through media in the H 2 O-Gate allows moisture to exit while filter regenerates its capacity to prevent moisture ingression. Plated steel core prevents filter media distortion. Inhalation Á Exhalation Temperature Difference C ( F) 5 (9) 45 (81) (72) (63) (54) (45) (36) (27) (18) Installation Dimensions mm (inches) (9) Effective applications 133,4 (5.25) Á Á Inches of water Pressure Drop Fluid Displacement l/min (USgal) 283 (75) 85 (225) 19 (.75) 12 (.47) 1.5 UN Straight Thread 184,2 (7.25) 416 (375) 1982 (525) 246 (675).75 (.18).5 (.73).25 (.36) bar (psi) Performs as a gate. During the inhalation cycle, the H 2 O-Gate proprietary media blocks the water vapor from entering the reservoir. During the exhalation cycle, the media allows the moisture in the reservoir air to exit. The moisture is blown off the media by the exiting air, restoring the media s water barrier capacity, and the moisture barrier mechanism is not affected by the amount of exposure to moisture. The reservoir air is maintained at a low relative humidity, and more importantly, at a lower dew point temperature than the ambient temperature % Air Exchange Highly effective In an operating system, the H 2 O-Gate vent breather creates a moisture barrier when there is a 2 C (5 F) degree difference between reservoir and ambient temperature and when there is a 1% exchange of air volume above the fluid Air Flow, SCFM Low pressure drop across media. The P indicator triggers at P,7 bar (1 psid) (during exhalation). NOTE: Mobile systems may actuate the indicator due to vibrations, in which case the element should be changed after 5 hours of operation. 3
4 DIRT-Gate Element Model Code BR21 DIRT-Gate media is made of a strong graded matrix especially designed for removing airborne contamination. This media is pleated to maximize surface area (high dirt holding capacity) and provides high efficiency (99% at 2 micron) with very low pressure drop. Specifications Housing Material - ABS Plastic Temperatures - Up to 121 C (25 F) Efficiency - 99% at 2 micron Installation Dimensions mm (inches) 133,4 (5.25) Á 19 (.75) 12 (.47) 15 (4.13) Features & Benefits Rugged ABS plastic housing can be exposed to temperatures as high as 121 C (25 F), and is corrosion resistant. Visual mechanical indicator, which triggers at,7 bar (1 psid) (during exhalation). Easy installation. Lightweight design requires only hand tightening. Low pressure drop across filter media reduces stress on reservoir and system components. Plated steel core prevents filter media distortion. Pressure Drop Inches of water UN Straight Thread Fluid Displacement l/min (USgal) 283 (75) 85 (225) 1416 (374) 1982 (524) 246 (636).75 (.18).5 (.73).25 (.36) bar (psi) Air Flow, SCFM NOTE: Mobile systems may actuate the indicator due to vibrations, in which case the element should be changed after 5 hours of operation. 4
5 V211 and V191 Spin-on Elements V211 Series Pressure Drop 3 Fluid Displacement l/min (USgal) 284 (75) 568 (15) 852 (225) 1136 (3) 1419 (375),7 (.18) Element Model Code V211B*R3 Element length (7.3) (11.3) Dimensions mm (inch) V211B1R3 Breather Pressure Inches of Water 2 1,5 (.73),2 (.3) Pressure bar (psi) 286 (11.3) 184 (7.3) V211B2R3 Breather Air Flow SCFM 126 (5.) See pages 5 & 6 for available adaptor options. V191 Series Pressure Drop Pressure Inches of Water Fluid Displacement l/min (USgal) 189 (5) 284 (75) 379 (1) 568 (15) 757 (2) 852 (225) 3,7 (.18) 2 1 V191B1R3 Breather V191B2R3 Breather,5 (.73),2 (.3) Pressure bar (psi) Element Model Code V191B*R3 Element length (5.8) 2-23 (8.) 23 (8.) 147 (5.8) Dimensions mm (inch) Air Flow SCFM 97,5 (3.84) See pages 6 & 7 for available adaptor options. 5
6 Spin-On Vent Filter Adaptors Models & Part Numbers Bayonet Adaptor Installation Part Number Description Vent Filters Applicable Bayonet,,4 bar (6 psi) check V211, BR11, BR Bayonet,,2 bar (3 psi) check V211, BR11, BR21 Vent Filter Bayonet, no check V211, BR11, BR21 P-772 Threaded pipe V211, BR11, BR Threaded pipe V Bayonet, no check V191 Bayonet Adaptor Threaded Pipe Adaptors Installation Dimensions For V211, BR11 & BR21 Part: P-772 3rd angle projection Standard Mounting Flange of a reservoir filler/breather assembly 21,7 (.853) 19,1 (.75) 82,6 (3.25) 25,4 (1.) All Vickers Vent Filters are easily applied to reservoirs via Spin-On adaptors. For V191 Part: / 4 NPT 1 1 / 2-16 UN For V191 Part: ,7 (.5) 63,5 (2.5) 19 (.75) 1 1 / 8-16 UN Bayonet style 1 / 4 turn connection with gasket 44,2 (1.74) 54,4 (2.14) 1 1 / 8-16 UN 3 / 4 NPT Roll pin 38,1 (1.5) 63,5 (2.5) 6
7 Bayonet Adaptors For V211, BR11 & BR21 W/Pre-vent Part: 92479,4 bar (6 psid) Part: 93865,2 bar (3 psid) Checked exhaust,2 bar (.3 psid) intake 3rd angle projection Pre-Vent Option In a system where the fluid level drops and rises with cylinder actuation, the Pre-Vent feature minimizes the amount of air exchange through the vent filter. As the oil level drops, air enters the reservoir and is cleaned as it passes through the vent filter. As the oil level begins to rise, the pressure-vent stops the air from escaping the reservoir, and the tank becomes pressurized up to a maximum of the pressure vent setting (either,2 bar or,4 bar (3 or 6 psi)). The next time the system cycles, and the oil level drops, the air inside the reservoir will expand to make up the difference in volume. CAUTION: The reservoir tank and system must be designed to withstand a pressure of either,2 bar or,4 bar (3 or 6 psi). 1 1 / 2-16 UN Pre-Vent exhale check Inhale check Bayonet style 1 / 4 turn connection with gasket Roll pin 38,1 (1.5) 63,5 (2.5) 61,5 (2.42) 73,4 (2.89) 7,6 (2.78) Note: Max. drain port pressure for variable pumps - Pump Pressure PVH,5 bar (7 psi) PVQ,35 bar (5 psi) PVB,35 bar (5 psi) PVE,35 bar (5 psi) VVA 2, bar (29 psi) VVB 1, bar (15 psi) Pre-Vent breather adaptor Hi fluid bar (6 psi) (pressurized) Lo fluid bar (3 psi) Bayonet Adapter with,4 bar (6 psid) Pressure Vent bar (psi),7 (1) For V211, BR11 & BR21 Part: Inhalation cycle Flow (CFM) Note: 2 CFM = 57 l/min / 2-16 UN bar (psi),56 (8) Bayonet style 1 / 4 turn connection with gasket 61,5 (2.42) 73,4 (2.89),42 (6),28 (4) Exhalation cycle,14 (2) Flow (CFM) 2 Roll pin 38,1 (1.5) 63,5 (2.5) 7
8 Vickers Recommended System Sampling Frequency Chart Systems with target cleanliness 17/15/12 or lower System Pressure < 14 bar (2 psi) bar > 21 bar (3 psi) (2-3 psi) 8 hours or less operation per day 4 months 3 months 3 months Over 8 hours of operation per day 3 months 2 months 2 months Systems with target cleanliness 18/16/13 or higher System Pressure < 14 bar (2 psi) bar > 21 bar (3 psi) (2-3 psi) 8 hours or less operation per day 6 months 4 months 4 months Over 8 hours of operation per day 4 months 3 months 2 months Initial commissioning or major rebuild Large system (2 liters (53 USgal) or more) and systems with servovalves Sample fluid before start-up Sample fluid during first day running Sample fluid after one week Sample fluid after one month operation Other systems Sample during first day running Sample after one month operation Systems in distress or immediately after a maintenance event (i.e. increased heat, erratic operation, unusual sound etc.) Immediate 8
Target Cleanliness Worksheet. Systemic Contamination Control
Target Cleanliness Worksheet Systemic Contamination Control Target Cleanliness Worksheet 1. SET A TARGET Eaton Recommended Cleanliness Code Chart PUMPS
More informationDesiccant Air Breathers DBE. Section 3: TNK SCHROEDER INDUSTRIES ACCESSORIES 21
Desiccant Air Breathers DBE Section 3: SCHROEDER INDUSTRIES ACCESSORIES 21 Reservoir Accessories A hydraulic systems reservoir can play a significant role in the ingression of contamination into the system.
More informationSULLAIR SX Filtration Series ,000 scfm
SULLAIR SX Filtration Series 25 21,000 scfm The Importance of Reliable Filtration Contaminants are introduced at various stages of the air compression cycle. Removing these contaminants is vital to help
More informationPRESSURE DIFFERENTIAL PRODUCTS 2008 TRICO CORPORATION. ALL RIGHTS RESERVED.
PRESSURE DIFFERENTIAL PRODUCTS 2008 TRICO CORPORATION. ALL RIGHTS RESERVED. TYPES OF VENTS Expansion chambers Some equipment by design needs to breath Majority of equipment will come with some type of
More informationFIK In-Tank Filters FIK. Max Flow: 170 gpm (643 lpm) Working Pressures to: Rated Static Burst to: Flow Range to:
LOW PRESSURE FILTERS Max Flow: gpm ( lpm) In-Tank Filters Working Pressures to: Rated Static Burst to: psi kpa bar psi kpa bar Flow Range to: gpm lpm Features STYLE C STYLE D STYLE E in-tank filters are
More informationE 328 E 498 Tank top mounting Connection up to G1½ / -24 SAE and SAE 2 Nominal flow rate up to 600 l/min / gpm
Return-Suction Filters E 8 E 98 Tank top mounting Connection up to G½ / - SE and SE Nominal flow rate up to 6 l/min / 8. gpm Description pplication For operation in units with hydrostatic drives, when
More informationTECHNICAL DATA MAINTENANCE AIR COMPRESSOR MODEL G-1
Dry 131h 1. DESCRIPTION The Viking Model G-1 Maintenance Air Compressor is an electric motor-driven, aircooled, single-stage, oil-less compressor. The unit is equipped with a check valve and provides a
More informationStandard Operating and Maintenance Instructions for Pumping System Model PS-90
Standard Operating and Maintenance Instructions for Pumping System Model PS-90 High Pressure Equipment Company 2955 West 17th Street, Suite 6 PO Box 8248 Erie, PA 16505 USA 814-838-2028 (phone) 814-838-6075
More informationSeries SFD. Clean Air Filter. Variations. Made to Order. Type. Cartridge (replaceable element) Disposable (non-replaceable element) Up to 100
Clean Air Filter Variations SFD SFD SFD SFD Made to Order Type Disposable (non-replaceable element) Cartridge (replaceable element) Flow rate L/min (ANR) (at inlet pressure.7 MPa) Up to 6 Up to 8 Up to
More informationModel 7989T Steel Pipe Squeezer Sch. 40 & Sch. 80. Operations Manual
10-12 Steel Pipe Squeezer Sch. 40 & Sch. 80 Operations Manual 1.0 Introduction This manual is issued as a basic operation manual covering the Regent Model 7989T, Pipe Squeezer and Pump as manufactured
More informationDirectional Controls
Vickers Directional Controls Directional Control Valves DG3V-3-*-60 Hydraulic Operated DG17V-3-*-60 Lever Operated DG18V-3-*-60 Air Operated DG20V-3-*-60 Cam Operated DG21V-3-*-60 Plunger Operated CETOP
More informationDirectional Controls
Vickers Directional Controls Lever Operator Directional Control Valves DG17S-8-**-10 DG17S4-10 **-50 NF D08/D10, ISO-4401-08/10 Released 5/94 681 able of Contents General Information..................................................................................
More informationE 084 Tank top mounting Connection up to G1 / -16 SAE Nominal flow rate up to 80 l/min / 21.1 gpm
Return-Suction Filters E 08 Tank top mounting Connection up to G / -6 SE Nominal flow rate up to 80 l/min /. gpm Description pplication For operation in units with hydrostatic drives, when the return flow
More informationE 328 E 498 Tank top mounting Connection up to G1½ and SAE 2 Nominal flow rate up to 600 l/min
Return-Suction Filters E 8 E 98 Tank top mounting Connection up to G½ and SE Nominal flow rate up to 6 l/min Description pplication For operation in units with hydrostatic drives, when the return flow
More informationACTUATORS AND INSTRUMENTS
ACTUATORS AND 03 ADVANCED ACTUATORS AND FOR A COMPLETE VALVE CONTROL SOLUTION Koso Kent Introl LIMITED (KKI) supplies a full range of advanced actuators and associated instrumentation to complement its
More informationE 094 E 103 E 143 Tank top mounting Connection up to G1 / -16 SAE Nominal flow rate up to 135 l/min / 35.7 gpm
Return Filters E 9 E E Tank top mounting Connection up to G / -6 SAE Nominal flow rate up to 5 l/min / 5.7 gpm Description Application In the return line circuits of hydraulic systems. Performance features
More informationTECHNICAL DATA. Q = C v P S
January 6, 2012 Preaction 331a 1. Description Viking supervised Double-Interlocked Electric/Pneumatic Release Preaction Systems utilize the Viking G-3000P Valve. The small profile, lightweight, pilot-operated
More informationInflatable Packer Single & Double. Single & Double Packer Dimension. Wireline Packer. Water Testing Packer (WTP) Packer
Inflatable Packer Single & Double Single & Double Packer Dimension Wireline Packer Water Testing Packer (WTP) Packer Packer Working Pressure & Depth Chart Packer Water Hand Pump Packer Air Driven Pump
More informationVickers. Flow Controls. Flow Controls FN, F(C)G, FRG. Released 6/94
Vickers Flow Controls Flow Controls FN, F(C)G, FRG Released 6/94 685 Table of Contents FN03/06/10 Model Series Application Data...............................................................................
More informationTECHNICAL DATA. Q = C v P S
Preaction 346a 1. Description The 6 Model G-6000P Electric Release Preaction System Riser Assembly can be used as a Single Interlock Preaction System with Electric Release, or as a Double Interlock Preaction
More informationTECHNICAL DATA. Q = C v P S
January 6, 2012 Preaction 347a 1. Description Viking supervised Double-Interlocked Electric/Pneumatic Release Preaction Systems utilize the Viking G-6000P Valve. The small profile, lightweight, pilot operated
More informationAIR-OPERATED DOUBLE DIAPHRAGM PUMP USER S MANUAL
00, 0, 000 00, 000, 00 A. TECHNICAL INFORMATION Model 00 Inlet/Outlet " Air Inlet /" 0 / 000 /" /" 00 /" /" 000 /" /" 00 /" /" Flow Rate GPM/ 0LPM GPM/ 0LPM GPM/ LPM GPM/ LPM GPM/ 0LPM GPM/ 0LPM Maximum
More informationAIRLINE-SERIES HELMET AIR FILTER
OWNER S MANUAL AIRLINE-SERIES HELMET AIR FILTER IMPORTANT WARNING FOR SAFER BLAST CLEANING 1. Use protective equipment: Abrasive-resistant clothing, safety shoes, leather gloves, ear protection, CE-approved
More informationPilot Check Valve: Metal Body Type
INFORMATION Pilot Check Valve: Metal Body Type The use of a metal body improves strength and environmental resistance. Temporary intermediate stops are possible. *1 *1 Precise intermediate stops are not
More informationTECHNICAL DATA. Q = C v P S
January 6, 2012 Preaction 348a 1. Description Viking supervised Surefire Preaction Systems utilize the Viking G-6000P Valve. The small profile, lightweight, pilot operated Viking G-6000P Valve comes complete
More informationTECHNICAL DATA. Q = C v P S
January 6, 2012 Preaction 333a 1. Description Viking supervised Surefire Preaction Systems Utilize the Viking G-3000P Valve. The small profile, lightweight, pilot-operated Viking G-3000P Valve comes complete
More informationCHECK-VALVES Automatically Position Themselves by the Natural Forces of the Conveying Air. A PNEUMATIC CONVEYING SYSTEM PATENT #: 5,160,222
PATENT #: 5,160,222 PHONE: (913)677-5777 FAX: (913)677-067 E-Mail : techair@techairinc.com www.techairinc.com CHECK-KLEEN DIVERTER A PNEUMATIC CONVEYING SYSTEM FLAP-CHECKS exposed to product air stream
More informationSERVICE MANUAL MODEL BA200AMST-S1 BREATHING AIR PANEL
1 SERVICE MANUAL MODEL BA200AMST-S1 BREATHING AIR PANEL WARNING: Do not attempt to operate this equipment without first reading and understanding the service manual enclosed with this device. 2 GENERAL
More informationINSTRUCTION MANUAL FOR UNDERWATER OPERATION
INSTRUCTION MANUAL FOR UNDERWATER OPERATION FOR HYDRAULIC HAMMER MODELS: H3XA, H4XE/4XL, H6XA, H7X Use Genuine NPK Parts 7550 Independence Drive Walton Hills, OH 44146-5541 Phone (440) 232-7900 Toll-free
More informationCopyright, 2005 GPM Hydraulic Consulting, Inc.
Troubleshooting and Preventive Maintenance of Hydraulic Systems Learning to Read the Signs of Future System Failures Instructed by: Al Smiley & Alan Dellinger Copyright, 2005 GPM Hydraulic Consulting,
More informationTECHNICAL DATA. Q = C v P S
Page 1 of 13 1. DESCRIPTION The Viking 6 Model G-6000 Dry Valve Riser Assembly consists of a small profile, light weight, pilot operated valve that is used to separate the water supply from the dry sprinkler
More informationPremAire INSTRUCTIONS FOR VORTEX TUBE MODE OF OPERATION
DUAL SUPPLY REGULATOR ESCAPE CYLINDER VORTEX MAIN INLET PremAire INSTRUCTIONS FOR VORTEX TUBE MODE OF OPERATION WARNING THIS MANUAL MUST BE READ CAREFULLY BY ALL PERSONS WHO HAVE OR WILL HAVE THE RESPONSIBILITY
More informationVB-7323 Series. Application. Features. Applicable Literature. 1/2 to 2 Screwed NPT Three-Way Diverting Valves General Instructions
VB-7323 Series 1/2 to 2 Screwed NPT Three-Way Diverting Valves General Instructions Application VB-7323 series three-way diverting valves control hot or chilled water in heating or air conditioning systems.
More informationINSTALLATION, MAINTENANCE & OPERATING INSTRUCTIONS 2-4 REDUCED PORT/ FULL PORT (5700/6700) ANSI CLASS 150/300/600/900/1500/2500 TRUNNION BALL VALVES
PBV-USA,Inc. 12735 Dairy Ashford. Stafford, Texas USA 77477 281-340-5400; 800-256-6193 FAX: 281-340-5499 INDUSTRIAL BALL VALVES IM0 69 April 2001 Rev 9 INSTALLATION, MAINTENANCE & OPERATING INSTRUCTIONS
More informationMUD 1. Vent check valves. Instruction and maintenance manual.
MUD 1 Vent check valves Instruction and maintenance manual. Version: 04-02-2011. 2 List of Contents 1. INTRODUCTION 3 1.1 The Problem... 3 1.2 The Solution... 3 2. RULES AND REGULATIONS 3 2.1 General requirements....
More informationE 158 E 198 E 248. Tank top mounting Connection up to G11 / 4 Nominal flow rate up to 250 l/min e d
R e t u r n - S u c t i o n F i l t e rs E 158 E 198 E 248 Tank top mounting Connection up to G11 / 4 Nominal flow rate up to 250 l/min 20.90-5e 0.0-2d D e s c r i p t i o n Application For operation in
More informationRegulator for 2 MPa ARX 20. How to Order. Bracket. Pressure gauge. Port size 1/8 1/4. Panel nut
Regulator for 2 MPa RX 2 How to Order RX2 1 Regulator 1 Regulating pressure.5 to.85mpa {.51 to 8.7kgf/cm²}.5 to.3mpa {.51 to 3.1kgf/cm²} Thread type Nil N F Rc(PT) NPT (PF) Port size 1 2 ccessories/options
More informationTURBINE SEAL: AXIAL TYPE DESIGN
TURBINE SEAL: AXIAL TYPE DESIGN Our axial type seals are specifically designed for application to hydroelectric turbines and large water pumps for sewage handling, filtration, irrigation, and more. Our
More informationFloat Operated Level Controllers
CONTENTS Float Operated Level Controllers IM0015 Nov. 2014 PAGE Introduction 1 Scope 1 Description 1 Specification 1 Control Installation 2 INTRODUCTION Side Mount Back Mount Prior to installing, the instructions
More informationLiquid Level Controllers
Liquid Level Controllers ALL PUMPS LLC-2Y For both pump up and down control. Variable On/Off set points. NDP-15/20/25/32, DP-10/15 & *NDP-40/50/80 LLC-1 Pump up and down versions available. 6 to 12 differential
More informationInstallation, Operation and Maintenance Manual for Back Pressure Regulator
Installation, Operation and Maintenance Manual for Back Pressure Regulator Model 8860 2009 Groth Corporation IOM-8860 Rev. B 12541 Ref. ID: 95565 Page 2 of 13 Table of Contents I. INTRODUCTION 3 II. DESIGN
More information170-CG Feed Unit SPONGE-JET USER MANUAL. Sponge-Jet, Inc. (USA) 14 Patterson Lane Newington, NH
SPONGE-JET 170-CG Feed Unit USER MANUAL Sponge-Jet, Inc. (USA) 14 Patterson Lane +1-603-610-7950 Newington, NH 03801 www.spongejet.com AUGUST 2014, Sponge-Jet 170-CG User Manual - REV A / DOC: M-MKTG-002ENG
More informationPVQ 13 A2 R SE 1 S 20 C-11 D
PVQ - Variable Displacement Piston Pump PVQ 13 A2 R SE 1 S 2 C-11 D 1 2 3 4 6 7 8 9 1 1 Model Series PVQ Inline Piston Pump Variable Volume Quiet Series 4 Rotation Viewed from shaft end R Right hand, standard
More informationTECHNICAL DATA OBSOLETE
April 9, 2009 Preaction 326a 1. DESCRIPTION Viking supervised Double-Interlocked Electric/Pneumatic Release Preaction Systems utilizing the Viking G-4000P Deluge Valve. The small profi le, lightweight,
More informationPurge Star & Ring Purge Systems
March 2013 Operator s Manual Purge Star & Ring Purge Systems Additional instruction for Purge Star Single Hose, Purge Star Double (bypass) Hose and Ring Purge with bypass hose and gas dump valve feature.
More informationSERVICE MANUAL MODEL BA600AMST-S1 BREATHING AIR PANEL
SERVICE MANUAL MODEL BA600AMST-S1 BREATHING AIR PANEL WARNING: Do not attempt to operate this equipment without first reading and understanding the service manual enclosed with this device. 2/05 GENERAL
More informationAdvanced Fluid Handling Cart Owner s Manual
Advanced Fluid Handling Cart IMPORTANT Please read this carefully and thoroughly before installing and operating your Advanced Fluid Handling Cart. Please retain this owner s manual for future reference
More informationINSTRUCTION MANUAL FOR UNDERWATER OPERATION
INSTRUCTION MANUAL FOR UNDERWATER OPERATION FOR HYDRAULIC HAMMER MODELS E-218A E-224A Use Genuine NPK Parts 7550 Independence Drive Walton Hills, OH 44146-5541 Phone (440) 232-7900 Toll-free (800) 225-4379
More informationDiscontinued. Powers Controls. Technical Instructions Document No P25 RV Rev. 1, May, RV 201 Pressure Reducing Valves.
Powers Controls RV 201 Pressure Reducing Valves Description Features Product Numbers Dual Pressure PRV Technical Instructions Document No. 155-049P25 RV 201-1 Single Pressure PRV The RV 201 Pressure Reducing
More informationTECHNICAL DATA. Q= Cv S
Page 1 of 13 1. DESCRIPTION The Viking 4 inch Model G-4000 Dry Valve Riser Assembly consists of a small profile, light weight, pilot operated valve that is used to separate the water supply from the dry
More informationMF2M Monnier Miniature Compressed Air Filter
5040050 / 2 IM-P504-02 CH Issue 2 MF2M Monnier Miniature Compressed Air Filter Installation and Maintenance Instructions 1. Safety information 2. General product information 3. Installation and commissioning
More informationACCUMULATOR OPERATING & MAINTENANCE INSTRUCTIONS
ACCUMULATOR OPERATING & MAINTENANCE INSTRUCTIONS READ ALL INSTRUCTIONS PRIOR TO INSTALLATION AND OPERATION TO AVOID POSSIBLE INJURY Warning: Always consider any accumulator to contain pressure until proven
More informationInstallation, Operation, and Maintenance Manual Parker Balston Model N2-04 Nitrogen Generator
Installation, Operation, and Maintenance Manual Parker Balston Figure 1 - N2-04 Nitrogen Generator These instructions must be thoroughly read and understood before installing and operating this product.
More informationE 441 E 451 E 461 E 641 E 700 Tank mounting Nominal flow rate up to 800 l/min
Return Filters E E E 6 E 6 E 7 Tank mounting Nominal flow rate up to 8 l/min Description Application In the return line circuits of hydraulic systems. Performance features Protectionagainst wear: By means
More informationLoad Controls Screw In Cartridge Valves Pressures to 350 bar (5000 psi) Flows to 190 l/min (50 USgpm)
Vickers Cartridge Valves Load Controls Screw In Cartridge Valves Pressures to 50 bar (5000 psi) Flows to 90 l/min (50 USgpm) Rev. 2/99 722 Contents MODEL DESCRIPTION TYP. APPLICATION PRESSURE bar (psi)
More informationUnit 24: Applications of Pneumatics and Hydraulics
Unit 24: Applications of Pneumatics and Hydraulics Unit code: J/601/1496 QCF level: 4 Credit value: 15 OUTCOME 2 TUTORIAL 9 ACCUMULATORS The material needed for outcome 2 is very extensive so there are
More informationP5513. Users Manual. Pneumatic Comparison Test Pump. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.
Test Equipment Depot - 800.517.8431-99 Washington Street Melrose, MA 02176 TestEquipmentDepot.com P5513 Pneumatic Comparison Test Pump Users Manual PN 3963372 November 2010 2010 Fluke Corporation. All
More informationNitrogen Tyre Inflator Owner s Manual
Nitrogen Tyre Inflator Owner s Manual Model:PN-8890 Please read this manual carefully before attempting assembly or use. 1 Suit for: Motorcycle, Car, Light Truck, Bus Manual Model Nitrogen Tyre Inflation
More informationCompressed Air - Food/Bev. Presented By: Adam Zimmerman
Compressed Air - Food/Bev Presented By: Adam Zimmerman Meeting Summary Metro Air Treatment Compressor Types & Selection Measurment Questions Metropolitan Air Compressor Co., Inc. Serving the Michigan Market
More informationTECHNICAL DATA CAUTION
Page 1 of 6 1. DESCRIPTION The Viking Model D-2 Accelerator is a quick-opening device, with an integral anti-flood assembly, used to increase the operating speed of a differential type dry pipe valve.
More information4 IN. BALL LAUNCHER Engine Mounted / PTO Driven
4 IN. BALL LAUNCHER Engine Mounted / PTO Driven OPERATOR S PARTS and MAINTENANCE MANUAL 2006 EDITION BL-MAN-4EN Creation Revision date: 10MAR06 date: by: Ivon LeBlanc by: Table of Contents Table of Contents...
More informationFull Internal Relief Valves Instruction Manual
Full Internal Relief Valves Instruction Manual MEV200FIR & MEV300FIR Application: Designed for use in mobile LPG & NH 3 containers as a primary pressure relief valve for bobtail and transport trailer installations.
More informationInert Air (N2) Systems Manual
INSTRUCTION MANUAL Inert Air (N2) Systems Manual N2-MANUAL 2.10 READ AND UNDERSTAND THIS MANUAL PRIOR TO OPERATING OR SERVICING THIS PRODUCT. GENERAL INFORMATION Positive pressure nitrogen gas pressurizing
More informationInstallation, Operation and Maintenance Instructions for Mild Steel Buffer Vessel
OM006 Installation, Operation and Maintenance Instructions for Mild Steel Buffer Vessel The operating and maintenance instructions contained within this package are for standard mild steel buffer vessels
More informationA hose layline contains important information for specifying the replacement assembly: manufacturer, hose trade name, working pressure and hose ID.
CONTENTS Introduction Pressure Pressure Drop Temperature Rating Bend Radius Conclusion Additional Information SIDEBAR: Understanding Hydraulic Hose Reinforcement INTRODUCTION Hydraulic hose has a finite
More informationDAV - P. Product Catalogue DAV - P. Air release & Vacuum Break Valves. (Plastic Air Valves) DAV - P. Edition 2012
Product Catalogue DAV - P DAV - P Air release & Vacuum Break Valves Edition 1 DAV - P (Plastic Air Valves) DAV Series Overview General The presence of trapped air in a pressurized pipeline can have serious
More informationSERVICE MANUAL MODEL BA200AA-S1 BREATHING AIR PANEL
SERVICE MANUAL MODEL BA200AA-S1 BREATHING AIR PANEL WARNING: Do not attempt to operate this equipment without first reading and understanding the service manual enclosed with this device. 1/00 2 GENERAL
More informationVPPL VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS FOR INTERMEDIATE PRESSURE SERIES 10
/ ED VPPL VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS FOR INTERMEDIATE PRESSURE SERIES OPERATING PRINCIPLE The VPPL are variable displacement axial-piston pumps with variable swash plate, suitable for applications
More informationBS Series Basket Strainer
BS Series Basket Strainer Operating, Installation, & Maintenance Manual Corrosion Resistant Fluid and Air Handling Systems. Dated 04-26-12 PRESSURE DROP SIMTECH strainers are engineered to offer the lowest
More informationMaintenance handbook
Maintenance handbook ontents HPU IDENTIFIATION SHEET... 4 1. MAINTENANE... 5 1.1 Filling level... 5 1.2 Fluid top-up... 5 1.3 Fluid replacing... 5 1.4 Fluid temperature control... 6 1.5 Functional control...
More informationFILTER TYPE PRESSURE SNUBBER
FILTER TYPE PRESSURE SNUBBER Pressure oscillations and other sudden pressure changes can affect the delicate mechanisms of a pressure gauge or pressure transmitter. This can result in either complete failure
More informationN2 Blanketing Valve DST100 / DST200 TYPE INSTRUCTION MANUAL CONTENTS K.S.P.C. General Description Operation. Installation Maintenance
DST100 / DST200 TYPE N2 Blanketing Valve INSTRUCTION MANUAL CONTENTS General Description Operation Installation Maintenance K.S.P.C 488-1 Wolha-ro, Tongjin-eup, Gimpo-si, Gyeonggi-Do, Korea Tel : +82-31-998-3825~7
More informationBest Practices Pneumatics Machine & Design. Written by Richard F. Bullers, CFPPS as published in Fluid Power Journal, July/August 2016
Pneumatics Machine & Design Written by Richard F. Bullers, CFPPS as published in Fluid Power Journal, July/August 2016 Contents at Atmospheric Air The air at a compressor s intake contains about 78% nitrogen,
More informationFixed Displacement Pump KFA for commercial vehicles in open circuits
RE 91 501/05.98 Replaces: 11.96 Fixed Displacement Pump KFA for commercial vehicles in open circuits Sizes 23...107 Series 6 Nominal pressure 300 bar Peak pressure 350 bar KFA List of contents Features
More informationPre-filter for Brushless Blower Instruction Manual
Pre-filter for Brushless Blower 781-70-702 Instruction Manual Minebea Co., Ltd. Industrial Machinery Business Unit 251-8531 1-1-1 Katase,Fujisawa,kanagawa Contact Us Industrial Machinery Product Sales
More information4400 TwinHybrid Gas Seal
4400 TwinHybrid Gas Seal EQUIPMENT PREPARATION MECHANICAL SEAL INSTALLATION INSTRUCTIONS 1 2 200.005" 0,13 mm 125 µ" 3,2 µm R a 3 4 32 µ" 0,8 µm R a 1000 ±.002" 0,05mm CAUTIONS These instructions are general
More informationTECHNICAL DATA SINGLE INTERLOCKED PREACTION SYSTEM WITH PNEUMATIC RELEASE
1 of 10 1. DESCRIPTION (Refer to Figures 1-3.) Viking supervised Single Interlocked Preaction Systems utilize a Viking Deluge Valve and a pneumatically pressurized automatic sprinkler system. The system
More informationPRESSURE REDUCING (AND CHECK) VALVES RT/RG RCT/RCG. -03/06/10 (3/8, 3/4, 1-1/4) Threaded Connections / Sub-plate Mounting
REDUING (ND HEK) VLVES RT/RG RT/RG -3// (3/8, 3/, -/) Threaded onnections / Mounting Up to MPa (5 PSI), 5 L /m in (3 U.S.GPM) Pub. E-3 Pressure Reducing Valves Pressure reducing valves are used to set
More informationCARTRIDGE FILTERS. Models: CF50, CF75, CF100, CF150,
CARTRIDGE FILTERS Models: CF50, CF75, CF00, CF50, The installation of this product should be carried out by a qualified pool technician, following the installation instructions provided in this manual.
More informationSeries BLK Oil - air cooler
Series BLK Oil - air cooler maintenance friendly design broad performance range compact dimensions rugged cooling matrix low noise emissions comprehensive accessories DE 35 0001 04/2004 Bühler Meß- und
More informationElectro-Pneumatic Converter YT-940 SERIES
Electro-Pneumatic Converter YT-940 SERIES PRODUCT MANUAL VERSION 1.00 Contents 1. Introduction 3 1.1 General information for the users. 3 1.2 Manufacturer Warranty 3 1.3 Explosion Proof Warning. 4 2. Product
More informationSeries IRV1000/2000/3000
CAT.ES60-16 A Regulator Series /2000/3000 Allows adjustment of vacuum line pressure Regulator Series /2000/3000 3 sizes offered in the series Variations have been expanded to three sizes from only one
More informationGRAVEL/ FILTERS IRRIGATION EQUIPMENT LTD. SERIES APPLICATIONS
IRRIGATION EQUIPMENT LTD. GRAVEL/ S A N D FILTERS SERIES 4000 APPLICATIONS Used as a Primary Filter for water from open reservoirs and recycled water. Most effective for filtration of water heavily contaminated
More informationElectropneumatic Transducer (I/P) Installation, Operation and
Nitra NCP1 Series Electropneumatic Transducer (I/P) Installation, Operation and Maintenance Instructions Ordering Information Contents Part Number I/P Transducers Output Range Input psig bar Section Description
More informationE 212 E 222 Tank top mounting Connection up to G1¼ / -20 SAE Nominal flow rate up to 220 l/min / 58.1 gpm
Return Filters E E Tank top mounting Connection up to G¼ / - SE up to l/min / 8. gpm Description pplication In the return line circuits of hydraulic systems. erformance features rotection against wear:
More informationGuardian Membrane Separators
Guardian Membrane Separators Our Guardian Membrane Separators and Spin Clean filters offer superb protection with easy field maintenance. The Guardian Membranes are ideal for protecting GC s, O 2 Analyzers,
More informationMUELLER. Mega-Lite Drilling Machine. Reliable Connections. table of contents PAGE. Equipment 2. Operating Instructions 3-4. Parts Information 5
operating Instructions manual MUELLER Mega-Lite Drilling Machine table of contents PAGE Equipment 2 Operating Instructions 3-4 Parts Information 5 Travel Charts 6-11! WARNING: 1. Read and follow instructions
More informationINSTALLATION. and INSTRUCTION MANUAL. for QUALITY AIR BREATHING SYSTEMS. Model 50 Systems Outfitted with ABM-725 Monitor C O M P A N Y
INSTALLATION and INSTRUCTION MANUAL for QUALITY AIR BREATHING SYSTEMS Model 50 Systems Outfitted with ABM-725 Monitor M A R T E C H S E R V I C E S C O M P A N Y OFFICE: (507) 843-4700 P.O. BOX 7079 Toll
More informationNew Product. Air Consumption 70% Down. Precision Regulator Air Saving Type. RPE Series PRECISION REGULATOR RPE SERIES CC-1072A
Air Consumption 70% Down New Product Precision Regulator Air Saving Type RPE Series PRECISION REGULATOR RPE SERIES Large Air Saving CC-1072A Air Consumption 70% Down. New Type Eco-friendly Precision Regulator
More informationAllspeeds Ltd. Royal Works, Atlas St Clayton le Moors Accrington Lancashire England BB5 5LW. Tel +44 (0)
Allspeeds Ltd. Royal Works, Atlas St Clayton le Moors Accrington Lancashire England BB5 5LW Tel +44 (0)1254 615100 www.allspeeds.co.uk HP690A Intensifier Panel including the following versions: Model Intensification
More informationTri-Tech Medical Inc.
Introduction Tri-Tech Medical manifolds are cleaned, tested and prepared for the indicated gas service and are built in accordance with the Compressed Gas Association guidelines. The manifold consists
More informationVB-7263 Series. Application. Features. Applicable Literature
TAC 1354 Clifford Avenue P. O. Box 2940 Loves Park, IL 61132-2940 www.tac.com VB-7263 Series 1/2" to 2" Screwed NPT Stainless Steel Trim with Teflon Disc Stem Up Closed, Two-Way Valves General Instructions
More informationRelated Products: Auto Drain Valve. Model/Specifications. Model
Related Products: Auto Drain Valve /600 Drainage is automatically discharged in a reliable manner, without requiring human operators. Highly resistant to dust and corrosion, operates reliably, and a bowl
More information444C DUAL PERFORMANCE VALUE PACK
(Chrome) PART NO. 44432 IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of this manual before installing and using this product. SAVE THIS MANUAL
More informationGeotech 1.66 Auto-Reclaimer
Geotech 1.66 Auto-Reclaimer Installation and Operation Rev 9 8/31/06 Part # 16600165 TABLE OF CONTENTS CHAPTER 1: SYSTEM DESCRIPTION... 3 FUNCTION AND THEORY... 3 SYSTEM COMPONENTS... 4 CHAPTER 2: SYSTEM
More informationGeotech 1.66 Auto-Reclaimer Installation and Operation
Geotech 1.66 Auto-Reclaimer Installation and Operation Rev 10/19/12 Part # 16600165 TABLE OF CONTENTS CHAPTER 1: SYSTEM DESCRIPTION... 3 FUNCTION AND THEORY... 3 SYSTEM COMPONENTS... 4 CHAPTER 2: SYSTEM
More informationBrownie s. Commercial Series NMCS-30 NMCS NW 1st Street, Fort Lauderdale, FL PH Fx
Brownie s M A R I N E G R O U P Commercial Series NMCS-7.5 NMCS-10 NMCS-20 NMCS-30 940 NW 1st Street, Fort Lauderdale, FL 33311 PH. 954.462.5570 Fx. 954.462.6115 This information is believed to be accurate
More informationAPPLICATION. Conveyors Metal working machines Machines for agriculture Road building machines Mining machinery Food industries
HYDRAULIC APPLICATION Conveyors Metal working machines Machines for agriculture Road building machines Mining machinery Food industries Special vehicles Plastic and rubber machinery etc. CONTENTS Specification
More information97C COMPRESSOR KIT 12V PART NO C COMPRESSOR KIT 24V PART NO C COMPRESSOR KIT PART NO
97C COMPRESSOR KIT 12V PART NO. 00097 97C COMPRESSOR KIT 24V PART NO. 02497 98C COMPRESSOR KIT PART NO. 00098 97C 98C IMPORTANT: It is essential that you and any other operator of this product read and
More informationVB-7211 Series. Application. Features. Applicable Literature. 1/2" to 1-1/4" Union End NPT Stem Up Open, Two-Way Valves General Instructions
TAC 1354 Clifford Avenue P. O. Box 2940 Loves Park, IL 61132-2940 www.tac.com VB-7211 Series 1/2" to 1-1/4" Union End NPT Stem Up Open, Two-Way Valves General Instructions Application VB-7211 series stem
More information