Mounting and Operating Instructions EB 8546 EN. Supply Pressure Regulator Type Fig. 1 Supply pressure regulators

Similar documents
Type 4708 Supply Pressure Regulator

Mounting and Operating Instructions EB 8546 EN. Type 4708 Supply Pressure Regulators. Translation of original instructions. Type Type

Type 4708 Supply Pressure Regulator

Type Pressure Regulator. for increased air capacity. Fig. 1: Type Pressure Regulator. Mounting and Operating Instructions EB EN

Mounting and Operating Instructions EB EN. Type Supply Pressure Regulator. with increased air capacity

Type 4708 Supply Pressure Regulator

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25

Mounting and Operating Instructions EB 2555 EN. Self-operated Pressure Regulators. Pressure Reducing Valves Type 50 ES Type 50 EM.

Type 3709 Pneumatic Lock-up Valve. Translation of original instructions. Mounting and Operating Instructions EB 8391 EN

Differential Pressure Regulator Type Type 45-6 (0.1 to 1 bar, DN 15) Mounting and Operating Instructions EB 3226 EN

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS

Mounting and Operating Instructions EB 3017 EN. Self-operated Regulators

Mounting and Operating Instructions EB 2558 EN. Self-operated Pressure Regulators. Type Pressure Build-up Regulator

Mounting and operating instructions EB 2530 EN. Self-operated Pressure Regulator. Pressure Reducing Valve Type M 44-2

Electropneumatic Positioner Type 4763 Pneumatic Positioner Type 4765

Series 44 Self-operated Pressure Regulators. Type 44-0 B Pressure Reducing Valve. ANSI version

Pressure Reducing Valve for Steam Type 2333 A

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Type Type Differential Pressure Regulators (opening)

Self-operated Pressure Regulators Type Universal Pressure Reducing Valve

Mounting and Operating Instructions EB 2172 EN. Series 43 Temperature Regulators. Type 43-5 and Type Type Type 43-6

Mounting and Operating Instructions EB 3009 EN. Self-operated Regulators. Type RS Check Valve (backflow protection)

Series 44 Self-operated Pressure Regulators. Type 44-1 B Pressure Reducing Valve. Type 44-6 B Excess Pressure Valve. ANSI version

Self-operated Pressure Regulators Type 2405 Pressure Reducing Valve

T 2523 EN Type 2406 Excess Pressure Valve Self-operated Pressure Regulators ANSI version

Self-operated Regulators Accessories Differential Pressure and Flow Regulators

Maximum 0.85 MPa pressure setting Long-life, high flow perfect for balancer applications

Direct Operated Precision Regulator Modular Style. Standard Specifications

Self-operated Pressure Regulators Type 2405 Pressure Reducing Valve

Series 42 Self-operated Regulators Differential Pressure Regulators with Type 2424/Type 2428 Actuator (closing) Type Type 42-28

Self-operated Pressure Regulators for special applications

Mounting and Operating Instructions EB EN. Self-operated Pressure Regulators. Type 2335 Excess Pressure Valve with pilot valve

Pressure Dump Valve Service Kit for Series 3000 Units

Pressure Dump Valve Service Kit for Series 2300 Units

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly.

OPERATING INSTRUCTIONS

Calibrated or locked versions available. TREATMENT > Series MD regulators GENERAL DATA. New

IP2M, IP2AM and IP2DM Monnier International Compressed Air Filter/ Regulators

Discontinued. Powers Controls. Technical Instructions Document No P25 RV Rev. 1, May, RV 201 Pressure Reducing Valves.

Regulator. Modular Type AR10 AR20 AR25 AR30 AR40 AR40-06 AR50 AR60. Pages 36 through 40 AR20K AR25K AR30K AR40K AR40K-06 AR50K AR60K

Regulator. Modular Type AR10 AR20 AR25 AR30 AR40 AR40-06 AR50 AR60. Pages 36 through 40 AR20K AR25K AR30K AR40K AR40K-06 AR50K AR60K

FOR INSTALLING CO 2 BLENDER KIT (P/N IN BEER SYSTEM

Regulator: Modular Type with Back flow Mechanism. AR30K to 60K. Body size. Port size 1/4 3/8 1/2 3/4 AR40 AR50 3/4 1/2

INSTALLATION INSTRUCTIONS. CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION

IP2, IP2A and IP2D. Spirax-Monnier International Compressed Air Filter/ Regulators

PRO-50 Instrument Supply Regulator

Mounting and Operating Instructions EB 9519 EN. Differential Pressure and Flow Meter Media 5. Zero adjuster

Series 44 Self-operated Pressure Regulators. Type 44-1 B Pressure Reducing Valve. Type 44-6 B Excess Pressure Valve

Manual Actuated Boiler Blowdown Valves

Power Valve: Precision Regulator. High precision, large capacity relief regulator

BCV31 DN20 - Blowdown Control Valve

Precision pressure regulators LRP/LRPS

Mounting and Operating Instructions EB 9520 EN. Differential Pressure and Flow Meter Media 05

DS05C,D,G Dial Set Pressure Regulating Valves

Model 130M Pneumatic Controller

Masoneilan* 78 Model Air Filter Regulator

1805 Series Relief Valves

Installation and operating manual. Pneumatic control station LK product no: PCS 1-10

Installation Instructions

ARI-DP32 / DP33 / DP34 / DP34T / DP34Tri / DP35 Pneumatic actuator ARI-DP

Series IRV1000/2000/3000

Pressure regulator for water

Description Supply pressure Pressure range Connection Device Page max. bar bar thread

How to Order RM0 0 Z. IN/OUT fitting type Metric size Inch size Straight Elbow Straight Elbow Straight Elbow Straight Elbow ø ø ø ø ø ø ø ø ø/ ø/ ø/ ø

OPERATING AND MAINTENANCE MANUAL

Compact Regulator. ARX20 Series. 2.0 MPa compatible, piston type compact regulator ARJ

IP2M, IP2AM and IP2DM Monnier International Compressed Air Filter/ Regulators

64 Series Pressure Reducing Regulators

Standard Operating and Maintenance Instructions for Pumping System Model PS-90

SIMPLAIR PIPING TOOL. JXT Company

MODEL 200 KNIFE GATE VALVES INSTALLATION & MAINTENANCE MANUAL

EB EN. Type 44-0 B Steam Pressure Reducing Valve Type 44-1 B Pressure Reducing Valve. Translation of original instructions

Air Saving Valve reduction in 40% air consumption 40% air consumption Air consumption reduction ratio (%) Flow valve Flow valv

Precision Regulator. Series Model Regulating pressure range Port size Page

Model: 720-UL INSTALLATION OPERATION MAINTENANCE. Bermad Pressure Reducing Valve IOM. Model: FP -720-UL Sizes: 2"-12" BERMAD. Application Engineering

SEries 29 Hydrant valves installation, operation & maintenance manual

BCV31 DN40 - Blowdown Control Valve

Air Saving Valve. Series ASQ. Series ASR. Pressure Valve. Flow valve TMH ASD AS AS-FG AS-FP AS-FM ASP ASN AQ ASV AK VCHC ASS. r r AS-FE KE 10 0.

Pressure Reducing Valve DMV 755

Air Saving Valve. Pressure Valve Flow Valve

Pressure booster combination DPA-CRVZS. Operating instructions a [ ]

KTM OM-2 SPLIT BODY FLOATING BALL VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

Filling valves AL, ALM Series Automatic filling units ALOMDIW, ALOMDNW Series

DS06D,G Dial Set Pressure Regulating Valve

Regulator for 2 MPa ARX 20. How to Order. Bracket. Pressure gauge. Port size 1/8 1/4. Panel nut

Lock Up Valves YT-400, YT-405 USER'S MANUAL

New Product. Air Consumption 70% Down. Precision Regulator Air Saving Type. RPE Series PRECISION REGULATOR RPE SERIES CC-1072A

Description Pressure range Connection thread Device Page

Safety Please read and keep in a safe place Operating instructions Linear flow control VFC Linear flow control with actuator IFC

Type S301 & S302 Gas Regulators INTRODUCTION INSTALLATION. Scope of Manual. Description. Specifications. Type S301 and S302. Instruction Manual

Pfeiffer. Operating, assembly and maintenance instructions for discontinuous sampling valve Series 27i. 1. Design, operation and dimensions

Serie ECO 3T. Threaded end back flow preventer with controllable reduced pressure zone. made in. Application fields. Protection E U R O P E

Pilot HON 625. Entwurf. Product information. serving the gas industry worldwide

Operating and maintenance manual Filter and reducing station Series / 1.0

Installation, Operation and Maintenance Manual for Back Pressure Regulator

OPERATION MANUAL Please read this Operation Manual carefully before use, and file for future reference.

Operating Manual FSV, FSÖV, SSVF

Mounting and Operating Instructions EB 9520 EN. Differential Pressure and Flow Meter Media 05

Product Manual. Description. Specifications. CVS Type 1301F and CVS Type 1301G Regulator. Introduction

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

Transcription:

Supply Pressure Regulator Type 4708 Type 4708-5352 on Type 3730 Positioner Type 4708-52 with filter receptacle Type 4708-6252 on Type 3372 ctuator Fig. Supply pressure regulators Mounting and Operating Instructions EB 8546 EN Edition February 2005

Contents Contents Page Design and principle of operation................... 4. Versions................................ 6.2 Technical data............................. 7 2 Mounting the supply pressure regulator................ 8 2. Compact supply pressure regulator................... 8 2.. Direction of flow............................ 8 2..2 Turning the supply pressure regulator.................. 9 2.2 Supply pressure regulators for attachment to positioners and actuators.. 0 3 Pneumatic connections........................ 4 3. Pressure gauge............................ 4 3.2 dditional connection for a solenoid valve............... 5 4 Set point adjustment......................... 8 5 Maintenance............................. 8 6 Troubleshooting........................... 9 7 ccessories.............................. 9 8 Dimensions in mm.......................... 20 2 EB 8546 EN

Safety instructions General safety instructions The supply pressure regulator may only be mounted, started up or serviced by fully trained and qualified personnel, observing the accepted industry codes and practices. Make sure employees or third persons are not exposed to any danger. ll safety instructions and warnings in these mounting and operating instructions, particularly those concerning assembly, start-up and maintenance, must be observed. Proper shipping and appropriate storage of the regulator are assumed. EB 8546 EN 3

Design and principle of operation Design and principle of operation The supply pressure regulator is used to supply pneumatic measuring and control equipment with a constant air supply. The maximum 2 bar pressure of the compressed air network in a plant is reduced to an adjustable minimum pressure of 0.2 to.6 bar or 0.5 to 6 bar. t the input side, the supply pressure regulator is equipped with a filter cartridge with a mesh size of 20 µm. In addition, the regulator can also be equipped with a filter receptacle and a pressure gauge on the outlet side. The compressed air at the input flows across the filter and through the free cross-sectional area between the seat (.) and plug (.2). It leaves the output with a reduced pressure depending on the plug position. The output pressure to be controlled is transferred via the bore (.3) to the operating diaphragm (2) where it is converted into a positioning force. This force is used to move the valve plug depending on the force of the positioning spring (4). Turning the set point screw (7) causes the spring force to change and, as a result, the required set point is adjusted. The set point ranges of the supply pressure regulator from 0.2 to.6 bar and 0.5 to 6 bar are determined by various tensions of the installed positioning spring (4). Condensed water contained in the compressed air can be collected and drained when the filter cartridge (9) is mounted horizontally or the filter receptacle (2) is suspended downwards. The stopper (0) or drain plug (5) can be unscrewed to drain condensed water. 4 EB 8546 EN

Design and principle of operation dapter plate/connecting plate Diverting gasket..2.3 2 3 4 5 6 7 8 Body. Seat.2 Plug.3 Bore 2 Operating diaphragm 3 Venting bore 4 Positioning spring 5 Cap 6 Lock nut 7 Set point screw 8 djustment knob 9 Filter cartridge 0 Stopper Bushing. Gasket 2 Filter receptacle 2. Gasket 3 Screw 5 Drain plug 9 0 0.. 2. 2 3 9 5 Fig. 2 Sectional drawings EB 8546 EN 5

Design and principle of operation. Versions Standard version Type 4708- Filter on aluminum basis without filter receptacle x x x x 0 With plastic filter receptacle With aluminum filter receptacle 2 Stainless steel supply pressure regulator Filter on stainless steel basis with stainless steel receptacle 3 With plastic filter receptacle 4 Without filter receptacle 7 Connection G ¼ 2 ¼-8 NPT 5 Set point range 0.5 to 6 bar (8 to 90 psi) Without pressure gauge 0 With pressure gauge, completely free of copper With pressure gauge, copper-free housing Set point range 0.2 to.6 bar (3 to 23 psi) Without pressure gauge 3 With pressure gauge, completely free of copper 2 4 Supply pressure regulator with adapter plate for positioners Type 3730, 3766, 3767, 3780, 3785, 3787 Type 3730, 3766, 3767, 3780, 3785, 3787 5 3 5 4 Type 4763/4765 5 5 0 Type 3760 5 7 Type 376 5 8 Supply pressure regulator with adapter plate for pneumatic actuators Type 3277 (240 to 700 cm 2 ) with Type 3730, 3766, 3767, 3780, 3785 or 3787 Positioner Type 3372 6 2 6 3 0 Filter without pressure gauge Type 4708- x x x 0 luminum housing and plastic filter receptacle luminum housing and aluminum filter receptacle Stainless steel housing and plastic filter receptacle Stainless steel housing and stainless steel filter receptacle 8 3 0 8 4 0 8 6 0 8 7 0 With pressure gauge, copper-free housing 5 6 EB 8546 EN

Design and principle of operation.2 Technical data Supply pressure regulator Supply pressure Output pressure Set point range ir consumption Permissible ambient temperature Input pressure dependance Reversing error Hysteresis Pressure gauge Ø40 indication range Type 4708-xx bar (5 psi) above the adjusted set point, however, at least.6 bar (24 psi) Max. 2 bar (80 psi) dustable from 0 to.6 bar (0 to 24 psi) or 0 to 6 bar (0 to 90 psi) 0.2 to.6 bar (3 to 24 psi) or 0.5 to 6 bar (8 to 90 psi) 0.05 mn 3 /h (with 7 bar supply air) 20 to 70 C ( 30 C possible, but in this case, air consumption reaching up to 0.3 m n 3 /h with 7 bar supply pressure) < 0.0 bar / p = bar 0. bar to 0.4 bar (depending on the set point) < 0. bar 0 to.6 bar (0 to 24 psi) or 0 to 6 bar (0 to 90 psi) Connection G /8 Type 4708-0 2 3 4 7 53 54 55 Weight, approx. 0.48 0.58 0.66.65.2.0 0.68 0.95 0.37 Type 4708-57 58 62 63 83 84 86 87 Weight, approx. 0.47 0.4 0.4 0.87 0.24 0.32 0.59 0.95 Materials Body dapter plate Stopper and gasket Cover Cap Plug Plug sealing Diaphragm Diaphragm plate Filter cartridge Polyamide, glass fiber reinforced luminum alloy, anodized black Polyamide, glass fiber reinforced and NBR Polyamide, glass fiber reinforced Polyamide, glass fiber reinforced Polyamide, glass fiber reinforced and polyoxymethylene NBRT and VMQ NBR Polyamide, glass fiber reinforced Polypropylene Pressure gauge housing connection Stainless steel St. steel (version free of copper) Brass, nickel-plated EB 8546 EN 7

Mounting the supply pressure regulator 2 Mounting the supply pressure regulator To prevent excessive amounts of condensed water from collecting, the distance between the compressor and supply pressure regulator should be kept as short as possible. Make sure the drain plug faces downwards in versions with a filter receptacle. 2. Compact supply pressure regulator The supply pressure regulator can either be mounted directly in the pipeline of the air supply or on rails or brackets using the corresponding mounting parts (see table in section 7 on page 9). Observe the direction of flow of the supply air. n arrow on the nameplate indicates the direction. 2.. Direction of flow In the compact supply pressure regulators 4708-0xx/-xx/-4xx and -7xx the direction of flow can be changed as follows:. Unscrew both fixing screws and lift the supply pressure regulator off its connecting plate. 2. Remove the diverting gasket, turn it 80 degrees and reposition it as shown in Fig. 3. Note! The long rubber finger of the gasket must always point in the direction of the regulator output. 3. Screw the supply pressure regulator tight onto the connecting plate. 4. Stick the enclosed adhesive label over the arrow of the nameplate, ensuring the arrow indicates that the supply air flows in the opposite direction. Connecting plate Standard label Gasket Connecting plate Label with arrow Fixing screws 4708-2. 3-... G 4708-2. G 3-... Supply pressure reglulator Long rubber finger always pointing towards the regulator output Fig. 3 Changing the direction of flow in compact supply pressure regulators 8 EB 8546 EN

Mounting the supply pressure regulator 2..2 Turning the supply pressure regulator The supply pressure regulator can be turned on its connecting plate to allow the set point adjuster to face either up or down.. Unscrew both fixing screws and lift the supply pressure regulator off its connecting plate. 2. Pull the diverting gasket out of the regulator and keep it in this position. 3. Turn the regulator 80 degrees and reinsert the gasket. In this way, you keep the bore assignment of the gasket for supply air input and regulator output. Note! The long rubber finger of the gasket must always point in the direction of the regulator output (reduced supply pressure). 4. Screw the regulator tight onto the connecting plate. Regulator facing upward Connecting plate or adapter plate Regulator facing downward Supply air input (Supply) > Fixing screws Diverting gasket Long rubber finger always pointing towards output Diverting gasket Front and back view Regulator output Supply air input Supply air input depending on the position of the gasket Regulator output (long rubber finger) Fig. 4 Turning the supply pressure regulator on its connecting plate or adapter plate EB 8546 EN 9

0 6 NPT Mounting the supply pressure regulator 2.2 Supply pressure regulators for attachment to positioners and actuators The supply pressure regulator versions intended for attachment to positioners and actuators are equipped with various adapter plates for the attachment. If required, the installation position of the supply pressure regulator can be changed by turning it 80 on its adapter plate to allow the adjustment knob to face either up or down. This applies particularly for positioners which can be attached either to the left or right side of the valve yoke to determine the operating direction and fail-safe action of the actuator. To turn the supply pressure regulator, proceed as described for the compact supply pressure regulator in section 2..2. The regulator is turned on its adapter plate instead of on the connecting plate. Regulators for Types 3730/3766/3767/ 3780/3785/3787 Positioners Type 4708-53xx for Type 327 ctuator up to 700 cm 2 and Type 3277 ctuator with 20 cm 2 as well as 240 to 700 cm 2 with hooked-up accessories. Insert the gasket (2) into the recess of the adapter plate (). 2. Place the supply pressure regulator on the positioner on the side where the pneumatic connections SUPPLY and OUTPUT are located. Screw tight using both M5 screws (3). 3. Close the spare connections with stoppers (4) to prevent dirt from entering the device. Type 4708-54xx for Type 327 ctuator with 400 and 2800 cm 2 or single-acting rotary actuators. Proceed to mount as for Type 4708-53xx. Type 4708-53xx 4 Type 4708-54xx 92 4708-535. 73 09 Fig. 5 ttachment onto positioners 2 3 0 EB 8546 EN

0 6 0 6 G SMSON 4763 Mounting the supply pressure regulator Type 4708-55xx for Type 4763 and Type 4765 Positioner. Screw the special nuts (5) into the connecting bores of the positioner. 2. Insert the gasket (2) into the recess of the adapter plate (). 3. Push the special hollow screws (6) for SUPPLY and (7) for OUTPUT into the connecting bores of adapter plate (). 4. Place the supply pressure regulator onto the positioner and screw it tight using both special screws. 5. Close the spare connections with stoppers (4) to prevent dirt from entering the device. 4 4708-552. 7 5 2 5 6 Type 4708-57xx for Type 3760 Positioner The attachment for a positioner mounted on the left side of the valve yoke (seen from the black switchover plate) is shown. For a positioner mounted on the right side, the adapter plate is attached in the same way, except the supply pressure regulator must be turned by 80 (see bottom of page 23). < Switchover plate. Screw the special nuts (5) into the connecting bores of the positioner. 2. Insert the O-rings (9) into the recess of the adapter plate (). 3. Push the special hollow screws (6) for SUPPLY and (7) for IN. SIGNL into the connecting bores of the adapter plate (). 4. Place the supply pressure regulator onto the positioner and screw it tight using both special screws. 5. Close the spare connections with stoppers (4) to prevent dirt from entering. 4 Fig. 6 ttachment onto positioners 7 5 9 5 6 EB 8546 EN

5 4 6 3 2 0 S Input 27 G Output Output 238 38 Mounting the supply pressure regulator Type 4708-58xx for Type 376 Positioner. Screw the special nut (5) into the SUPPLY connecting bore of the positioner. 2. Push the special hollow screw (6) into the connection bore of the adapter plate (). 3. Insert the O-ring (9). Position the supply pressure regulator and screw it tight to the positioner with the special screw. 4. Close the spare connections with stoppers (4) to prevent dirt from entering the device. Type 4708-63xx for Type 3277 ctuator Before attaching the supply pressure regulator, check whether the tongue of the gasket (.2) is aligned at the adapter block () in such a way that the actuator symbol (.3) indicating ctuator stem extends or ctuator stem retracts matches the fail-safe action of the actuator. If this is not the case, unscrew the three fixing screws (3), lift off the cover plate (.) and turn the gasket (.2) by 80 and reinsert it. 4 2 3 G3/8 5 6 9. Place the adapter block on the positioner and actuator yoke and fasten using fixing screws (2)...2.3 Fig. 7 ttachment of supply pressure regulators 2 EB 8546 EN

Mounting the supply pressure regulator Type 4708-62xx for Type 3372 ctuator. Screw the special nut (5) into the SUPPLY connecting bore of the actuator. 2. Push the special hollow screw (6) into the connecting bore of the adapter plate. 3. Insert the O-ring (9). Position the supply pressure regulator and screw it tight onto actuator using the special screw. 4. Close the spare connections with stoppers (4) to prevent dirt from entering the device. 6 5 9 4 9 5 4 6 Fig. 8 ttachment to Type 3372 ctuator EB 8546 EN 3

Pneumatic connections 3 Pneumatic connections The pneumatic connections are designed either as G /4 or /4 NPT-8 threads. In compact supply pressure regulators, an arrow on the adhesive label indicates the direction from the supply air input to the output. In supply pressure regulators with two connecting bores in the adapter plate (Figs. 5 and 6, top), the supply air connection is marked SUPPLY. The positioner's output signal is led in these versions via the OUTPUT bore through the adapter plate to the actuator. 3. Pressure gauge Mount the pressure gauge in such a way that there is a 2-3 mm gap between the lock nut and pressure gauge's square end after tightening the lock nut (20). In the compact versions 4708-2xx/3xx, make sure additionally that the stopper (23) is only screwed in to the point where it becomes aligned with the housing, otherwise the gaskets (2, 22) will be damaged. Each gasket is assigned either to the pressure gauge or to the stopper and must be changed correspondingly if you change the location of the pressure gauge and stopper to the other side. 20 2 22 23 2...3 mm 0 mm Fig. 9 Pressure gauge attachment, e.g. with Type 4708-2xx/3xx Supply Pressure Regulators 4 EB 8546 EN

Pneumatic connections 3.2 dditional connection for a solenoid valve n intermediate plate must be mounted between the connecting or adapter plate and the regulator to connect a solenoid valve. The reduced supply pressure of the supply pressure regulator is additionally led to the threaded connection at the side via the corresponding bores in the intermediate plate. ll supply pressure regulators have the same intermediate plate, except for Type 4708-57xx, designed for attachment to Type 3760 Positioner (Fig. 2), its intermediate plate has a different bore assignment for the air ducts. ll versions can be ordered made of aluminum or stainless steel and with either G or NPT threads. See section 7 for more details. Output for reduced supply air. E SUPPLY 2 2. E 3 Intermediate plate (2) with additional connection 4 4. E E Fig. 0 Mounting an intermediate plate for Types 3730/3766/3767/3780 Positioners EB 8546 EN 5

Pneumatic connections Mounting the intermediate plate. Remove the fixing screws and lift the supply pressure regulator (4) together with the diverting gasket (3) off the adapter plate (). Make sure you do not change the position of the diverting gasket in the supply pressure regulator. Note! The long rubber finger of the diverting gasket (3) must always point in the direction of the regulator output (reduced supply air). See Figs. 0,, 2. 2. Insert O-rings (2.) in the bores of the intermediate plate (2). 3. Place the intermediate plate onto the adapter plate in such a way that the three holes located next to one another Supply air input. E M Intermediate plate (2) 2 2. Output for reduced supply air 3 4 4. E E E Fig. Mounting an intermediate plate on Type 3372 ctuator 6 EB 8546 EN

Pneumatic connections are positioned over both 5 mm holes on the adapter plate and the bores (.) for the fixing screws are aligned. 4. Place the supply pressure regulator (4) with the diverting gasket (3) onto the intermediate plate (2). Insert the longer fixing screws and screw tight.. SUPPLY E 2 E 2. 3 E 4 E 4. M Fig. 2 Mounting an intermediate plate on Type 3760 Positioner EB 8546 EN 7

Set point adjustment 4 Set point adjustment (Fig. 2) Depending on the version, the set point of the supply pressure regulator can be adjusted either at the adjustment knob (8), or after screwing off the cap (5), at the set point screw (7). Turning the knob or screw clockwise increases the output pressure and turning it counterclockwise reduces the output pressure. Use the lock nut (6) to secure the setting. Note! When using the version with the adjustment knob (8) to adjust the set point, make sure that the Phillips screws are screwed tight to prevent the knob from coming loose due to possible vibrations. 5 Maintenance (Fig. 2) We recommend you check the filter as often as possible. Drain condensed water that has collected by removing the stopper (0) or by unscrewing the drain plug (5) about half a turn. When faults occur, e.g. a pressure drop, unscrew the stopper (0) or the filter receptacle (2) and replace the filter cartridge (order no. 8504-9027). Prior to carrying out any maintenance work, shut off the air supply! In the version with a filter receptacle, screw the fixing screw (3) tight so that the filter cartridge sits properly. Replace the gasket (2.) order no. 0439-006, if necessary. In the versions 4708-xx/4xx, do not unscrew the bushing (), if at all possible. If, however, you needed to unscrew it, you can replace the gasket (.) order no. 0439-0287 as well. If there is any leakage at the stopper (0), the entire stopper and seal ring (0.) order no. 099-387 must be replaced. 8 EB 8546 EN

Troubleshooting 6 Troubleshooting Leakage between supply pressure regulator and adapter plate: Check whether the diverting gasket (Figs. 3 and 4) is installed and both fixing screws are tightened properly. Excessive blow-off over the venting bore (3 in Fig. 2): Check whether the diverting gasket (Figs. 3 and 4) is installed correctly. The air supply decreases and the output pressure drops: Check the filter cartridge (9 in Fig. 2) for dirt and make sure the set point is correctly adjusted. 7 ccessories ccessories Mounting parts for mounting on rail acc. to EN 50022 acc. to EN 50035 Order no. 400-734 400-7342 Mounting parts for mounting on bracket for Type 327ctuator 400-7343 Intermediate plate for additional connection with Types 4708-0xx/-xx/-53xx/-55xx/-58xx/-62xx/-63xx luminum with G ¼ thread luminum with /4 NPT thread Stainless steel with G ¼ thread Stainless steel with /4 NPT thread 400-7400 400-7404 400-7402 400-7406 Intermediate plate for additional connection with Type 4708-57.. Supply Pressure Regulator luminum with G ¼ thread luminum with /4 NPT thread Stainless steel with G ¼ thread Stainless steel with /4 NPT thread 400-740 400-7405 400-7403 400-7407 djustment knob for set point adjustment 400-7408 Nut for panel mounting 400-7725 EB 8546 EN 9

Dimensions in mm 8 Dimensions in mm Type 4708-0xx/7xx Supply Pressure Regulator Type 4708-xx/4xx Supply Pressure Regulator 39 43 50 78 43 50 78 26 60 4708-2. 3-... 44 G 78 (02) 9 50 90(24) 9 50 Mounting bracket (accessories) Supply pressure regulators with intermediate plate for additional connection have an overall height increased by 24 mm. The dimensions in parentheses apply. 90 20 EB 8546 EN

Dimensions in mm Type 4708-2xx/3xx Supply Pressure Regulator 42 57 99 Type 4708-83xx/84xx/86xx/87xx Supply Pressure Regulator 59 44 44 42 3 25 99 9 4 2 4 5 22 5 Type 4708-53xx Supply Pressure Regulator for Types 3730/3766/3767/3780/3785/3787 Positioners 85(89) Output 70 28 4708-535. NPT 56 Supply EB 8546 EN 2

G Dimensions in mm Type 4708-54xx Supply Pressure Regulator for Types 3730/3766/3767/3780/3785/3787 Positioners G3/8 45 09 2 32 43 80 88 Type 4708-55xx for Types 4763/4765 Positioners 25 Output 0 SMSON 4763 20 6 0 6 4708-552. 55 66 (90) Supply 22 EB 8546 EN

9 9 Dimensions in mm 27 Input Signal Supply Type 4708-57xx Supply Pressure Regulator for Type 3760 Positioner Supply 27 20 Input Signal 47 99 22 33 (57) EB 8546 EN 23

5 4 6 3 2 0 27 G Output Output 238 38 Dimensions in mm Type 4708-58xx for Type 376 Positioner 93 60 (84) Supply 30 56 Type 4708-63xx for Type 3277 ctuator ttachment on left or right G3/8 09 32 45 SMSON S Input 2 43 80 88 24 EB 8546 EN

G Dimensions in mm Type 4708-622 for Type 3372-03x ctuator (35) 9 94 Supply Supply 4708-622X 60 3 EB 8546 EN 25

SMSON G MESS- UND REGELTECHNIK Weismüllerstraße 3 6034 Frankfurt am Main Germany Phone: +49 69 4009-0 Fax: +49 69 4009-507 Internet: http://www.samson.de EB 8546 EN S/Z 2005-03