RHPS Series RD(H)F40 User Manual. Read the complete manual before installing and using the regulator.

Similar documents
RS(H)20, 25 USER MANUAL

RD(H)20/25 Pressure-Reducing Regulator User Manual

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

LRS(H)4 USER MANUAL. Read the complete manual before installing and using the regulator.

PRS(TC)4,8 USER MANUAL. Read the complete manual before installing and using the regulator.

LRS(H)4 Pressure-Reducing Regulator User Manual

RHPS Series PRV 6 User Manual

RHPS Series PRV 2 all types of connections User Manual

Tank Blanketing Pressure Regulators RHPS Series

THE HF-300 SERIES. Operating and Service Manual. Series includes all variants of HF-300/301

INSTALLATION INSTRUCTIONS. CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION

1200B2 Series Service Regulators. Instruction Manual

1800C and 1800C-HC Series Service Regulators

THE BP-301 SERIES. Operating and Service Manual. Series includes all variants of BP-301 (LF 0.1Cv / MF 0.5Cv)

THE MF-400 SERIES. Operating and Service Manual. Series includes all variants of MF-400/401

Mounting and operating instructions EB 2530 EN. Self-operated Pressure Regulator. Pressure Reducing Valve Type M 44-2

Type ACE97. Introduction. Installation. P.E.D. Categories. Specifications. Overpressure Protection. Installation Guide English May 2002

THE BP-690 SERIES. Operating and Service Manual. Series includes all variants of BP-LF/MF-690/691

Propor tional Re lief Valve s

MEGR-1627 Instruction Manual

Installation Troubleshooting Maintenance Instructions Installation / Start-up

N2 Blanketing Valve DST100 / DST200 TYPE INSTRUCTION MANUAL CONTENTS K.S.P.C. General Description Operation. Installation Maintenance

Model GP PRESSURE REDUCING VALVE Installation & Operation Manual

Types S100K and S102K Pressure Regulators

Type S301 & S302 Gas Regulators INTRODUCTION INSTALLATION. Scope of Manual. Description. Specifications. Type S301 and S302. Instruction Manual

Proportional Relief Valves

Differential Pressure Regulator Type Type 45-6 (0.1 to 1 bar, DN 15) Mounting and Operating Instructions EB 3226 EN

Operation Manual. Diaphragm Sensed Gas Pressure Regulators

WW-720. Pressure Reducing Control Valve

THE HF-210 SERIES. Operating and Service Manual. Series includes all variants of HF-210/211. Issue A October 2014 *Section 6.

V DGX Series. Direct-Operated Regulators Manual D103834X012

Operation Manual Piston Sensed Gas Pressure Regulators

DN 50 REGULATOR SUTON 5000A1 REGULATOR SUTON 5000D1

299H Series. Introduction. P.E.D. Categories. Specifications. Installation. Warning. Installation Guide English September 2012

MEGR-1912 Instruction Manual

OPERATING AND MAINTENANCE MANUAL

Type HSR Pressure Reducing Regulator for Residential, Commercial, or Industrial Applications

Types PT and ETP Dome-Loaded Pressure Regulator Valves

Operating Manual. R280 Pressure regulator made of brass. 1. Intended Use

WW-720. Pressure Reducing Control Valve

Assembly Drawing: W-311B-A01, or as applicable Parts List: W-311B-A01-1, or as applicable Special Tools: , , &

WW-730. Pressure Sustaining/Relief Control Valve

Reduce pressure zone device suitable for high and medium hazard rated applications BSP screwed connections

64 Series Pressure Reducing Regulators

Bermad Pressure Reducing. Model: 42T

Model VR6 System. Installation, Operation & Maintenance

Anderson Greenwood Series 93 Positive Pressure POSRV Installation and Maintenance Instructions

Model: 720-UL INSTALLATION OPERATION MAINTENANCE. Bermad Pressure Reducing Valve IOM. Model: FP -720-UL Sizes: 2"-12" BERMAD. Application Engineering

Model 1800 PFM Series Regulator For Constant Outlet Pressure Precise Fixed Factor Measurement From 0.5 to 30 PSIG

Mooney* FlowMax* Regulator

Model GPR Primary Pressure Regulating Valve. Instruction Manual

VALVCHEQ BACKFLOW PREVENTERS FIGURE RP03

Types S108K and S109K Pressure Reducing Regulators with Integral Slam-Shut Device

SALCO PRODUCTS, INC. PRESSURE RELIEF VALVE STORAGE, INSTALLATION, OPERATING, MAINTENANCE/TESTING, AND INSPECTION INSTRUCTIONS

Product Manual. Description. Specifications. CVS Type 1301F and CVS Type 1301G Regulator. Introduction

Self Control Valves. User s Manual. Pressure Reducing Type (V182,V82) Pressure Relief Type (V185) Pressure Retaining Type (V186)

Regulator from 1800 B series

Type CT88 Backpressure Regulator

Model Secure-Gard Pilot Operated Vent Valve SECTION II. Remove all packing material inside and outside of the valve prior to installation.

627 Series Pressure Reducing Regulators

Type OS2 Slam-Shut Device

Anderson Greenwood Series 400 Diaphragm Pilot Operated Safety Relief Valves. Installation and Maintenance Instructions for

Type FL Pressure Reducing Regulators

Installation, Operation, and Maintenance Manual

Installation Operation Maintenance. Bermad Level Control Valve with Modulating Horizontal Float Pilot valve One Way Flow IOM.

KTM OM-2 SPLIT BODY FLOATING BALL VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

Welker Sampler. Model GSS-1. Installation, Operation, and Maintenance Manual

Helium-Oxygen Blender

Un-Pressurized Orefice Fittings FIO EZ. Parts List and Operation Instructions TECHNICAL MANUAL. Dn 2-6 Class Lbs

627 Series Pressure Reducing Regulators

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER CONSTANT PRESSURE CYLINDER

SERIES 500 VARIABLE RANGE PNEUMATIC DIFFERENTIAL PRESSURE TRANSMITTER

Pressure Regulators. Operating Instructions. Instrumentation

Carter Option X Valve connector assembly. Maintenance manual

FUNDAMENTALS OF PRESSURE REGULATORS ROBERT BENNETT MANAGER OF TRAINING ELSTER AMERICAN METER

GM Series Dual-Block Multi-Function Gas Control Valves

Installation, Operation, and Maintenance Manual. Welker Constant Pressure Cylinder With Solid Indicator (Non-mixer) Model CP-30SI

FILTER REGULATORS MODEL NO: CAT155 & CAT156 FITTING & MAINTENANCE INSTRUCTIONS PART NO: & ORIGINAL INSTRUCTIONS

Model: 43T. Bermad Pressure Relief Valve

1305 Series Pressure Reducing Regulators

1800CPB2 Service Regulators

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER FILTER DRYER

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25

Model 1800 PFM Series Regulator. Technical Bulletin

1805 Series Relief Valves

WHEATLEY WHEATLEY SERIES 500 SWING CHECK VALVE. Installation, Operation and Maintenance Manual

Cash Valve TYPE KP PILOT OPERATED BACK PRESSURE VALVE. ISSUED - DECEMBER 2000 CAVMC-0518-US-0208 ISO 9001 Certified

1800CPB2 Service Regulators Maximum Inlet Pressure 125 PSIG

GS/GSD Series Precision Back Pressure Regulator

61 Series Pilots for Pilot-Operated Pressure Reducing Regulators

Type ACE95jr Tank Blanketing Valve

Smooth Vent Valve. Series XVD XL XL Q D- XVD XGT CYV

ANDERSON GREENWOOD SERIES 9000 POSRV INSTALLATION AND MAINTENANCE INSTRUCTIONS

299H Series Pressure Reducing Regulators

ANDERSON GREENWOOD TANK BLANKETING REGULATORS

Needle valve. Contents. User s Manual. (1) Be sure to read the following warranty clauses of our product 1. (2) General operating instructions 2

Pressure Dump Valve Service Kit for Series 2300 Units

Wafer Check Valve. Contents. User s Manual. (1) Be sure to read the following description of our product warranty 1

Smooth Vent Valve XVD. Series

English. Introduction. Safety Instructions. All Products. Inspection and Maintenance Schedules. Parts Ordering. Specifications WARNING WARNING

Transcription:

RHPS Series RD(H)F40 User Manual Read the complete manual before installing and using the regulator.

2 WARNING Before removing a regulator from the system for service, you must depressurize system purge the system to remove any residual system media left in the regulator. Contents Introduction... 3 Installation... 4 Operation... 7 Maintenance... 8 Testing... 9 Troubleshooting... 9 2

Introduction Representative drawing of the standard RD(H)F40 1 body 11 valve spring 22 ring 34 dynamic regulation tube 2 dome 13 guide ring 23 socket head cap screw 35 male connector 3 bottomplate 14 retaining ring 24 ring 36 tube 3/8 4 valve case 15 ring 25 socket head cap screw 37 pilot regulator 5 valve case ring 16 socket head cap screw 27 tube 38 o-ring 6 valve stem 17 valve insert 28 flange 39 blindplug 1/4" bsp 7 bodyplate 18 diaphragm 30 bonded seal 8 domeplate 19 o-ring 31 male connector 9 diaphragmplate 20 o-ring 32 tube 3/8 10 seat 21 o-ring 33 bleedplug 1/4" bsp

Installation WARNING When installing a Swagelok self-venting regulator, position the vent connection or line away from operating personnel. Operating personnel must protect themselves from exposure to system fluids. Do not use the regulators as a shutoff device. When using the RDHF40 with an inlet pressure higher than 200 bar (2 902 psig), a safety valve must be installed in the outlet line, because the outlet pressure may not exceed 200 bar (2 902 psig). Connections to System The preferred mounting position of the regulator is horizontal with the dome facing upwards. If grounding is required, connect a ground wire under a spring housing bolt. Filling the dome The dome can be filled using manual or electronic loading. Manual loading: 1. This can be done by taking the gas pressure from the system and feeding this through a spring loaded pilot regulator into the dome. This is shown in sketch A. 2. In liquid systems the gas pressure for manual dome loading can be taken from a cylinder or mains. This is shown in sketch B. Substituting the spring loaded pilot regulator for a proportional control valve and a pressure sensor, allows you to control the pressure electronically. Electronic loading: 1. This can be done by taking the gas pressure from the system and feeding this through a proportional control valve into the dome. This is shown in sketch C. This method can be used for low and medium pressure systems. 2. This can be done by taking the gas pressure from the system and feeding this through a proportional controlled ratio regulator into the dome. This is shown in sketch D. This method can be used for high pressure systems.

The best results will be achieved by allowing a small flow to continuously pass through the pilot regulator. This flow can either be vented or, in gas systems, fed back through an orifice into the downstream piping. This is usually referred to as dynamic regulation. It is not recommended to place a gauge on the dome to set or check the outlet pressure. Because of forces in the regulator, the dome pressure will always be higher than the outlet pressure. Place a gauge in the outlet line to set or check the outlet pressure.

External feedback When using the regulator with external feedback, option EF, make sure that the outlet pressure can be fed back to the external feedback connection before applying pressure to the regulator. Failing to do so may lead to damage and non-functioning of the regulator as the inlet pressure will be put straight through to the outlet. The purpose of the external feedback on a pressure regulator is to get a more accurate regulation of the outlet pressure. This can be achieved by sensing the outlet pressure downstream of the regulator and feeding it back to the regulator. For this purpose Swagelok has provided a special connection, marked on the regulator itself as "P2 feedback". Connecting the external feedback The external feedback must be installed as follows: The external feedback is to be connected in a turbulence-free zone in the downstream piping, at a maximum distance of 5x the outside diameter of the down stream piping. The external feedback must be connected on top of the downstream piping. The tube-size of the external feedback should be ⅜ in. or ½ in.. Never connect the external feedback line downstream of a shut-off valve. Principle sketch of external feedback:

Operation Note: All handle directions are when viewed from above. Inlet and set pressure settings are obtained by adjusting pressure in the dome. Increase the pressure in the dome to increase the inlet pressure. Decrease the pressure in the dome to decrease the inlet pressure. Icing of the regulator at high flow rates or high pressure drops may occur if the gaseous media or atmosphere contains moisture. An auxiliary upstream filter is recommended for use in all but the cleanest of media. Installation of a downstream pressure relief is recommended for regulator and system protection. If the shut-off valve at the outlet side is closed after changing the set pressure, the outlet pressure will rise a little because of the closing force required for bubble-tight closing of the regulator. This phenomenon is usually referred to as the lock-up and does not indicate a problem with the regulator. A decrease in the flow will result in a rise of the outlet pressure. An increase in the flow will result in a fall of the outlet pressure and is usually referred to as the droop. This phenomenon does not indicate a problem with the regulator. A decrease of the inlet pressure will result in a rise of the outlet pressure. An increase of the inlet pressure will result in a fall of the outlet pressure. This phenomenon is usually referred to as the dependency or supply pressure effect and does not indicate a problem with the regulator. If the pilot regulator also has changing inlet pressures, this will make the pressure difference in the outlet line of the dome regulator even bigger. This is because the pilot regulator will also increase it s outlet pressure, which is the dome pressure. Any rise to the dome pressure will result in a rise of the outlet pressure. When using the RD(H)F40 with an inlet pressure higher than 200 bar (2 902 psig), a safety valve must be installed in the outlet line, because the outlet pressure may not exceed 200 bar (2 902 psig).

Maintenance Required tools for maintenance a vice to fasten the regulator pincers to take out the o-rings a pair of tongs for a retaining ring 140 mm a torque wrench a torque wrench hexagon head key 10 and 14 media and temperature compatible lubricant for reassembling threaded parts media and temperature compatible lubricant for o-rings Snoop liquid leak detector Disassembly Loosen the hexagon socket head screws and remove the dome, dome plate, diaphragm and diaphragm plate. Loosen the hexagon socket head screws and remove the bottom plate, valve, valve spring and seat. Inspection of disassembled parts Check all parts for abnormal wear. Replace parts in case of doubt. Points of attention before assembly - All parts must be clean and undamaged before starting assembly. - Swagelok recommends replacing all o-rings and the diaphragm before assembly. - All threaded parts must be lightly lubricated before assembly to avoid galling of threads. - All o-rings need to be lightly lubricated to improve the lifetime of the o-ring and the performance of the regulator. Assembly Follow the points for disassembly in reverse order to assemble the regulator. Recommended torques Only tighten the bolts or parts if the regulator is completely depressurized. Hexagon socket head screws M12 50 N m (442 in. lb) Hexagon socket head screws M16 90 N m (796 in. lb)

Testing Check the regulator for leakage across the seat, with low- and high inlet pressure. Check the regulator for leakage across the diaphragm, with low- and high outlet pressure. A well performing RD(H)F40 is 100 % bubble tight. If there is a leakage across the seat or the diaphragm, the damaged parts must be replaced. Troubleshooting The outlet pressure creeps up, without increasing the dome pressure. A damaged valve and/or seat. Replace the valve and/or the seat. Leakage around the bottom plate. A damaged o-ring or insufficient torque on the body plug. Replace the o-ring or tighten the bolts according to the torque specifications. Leakage between the body and the dome. A damaged diaphragm or insufficient torque on the bolts. Replace the diaphragm or tighten the bolts according to the torque specifications. Controlled pressure drops off sharply even when the flow is within regulator capabilities. The systems filter element is clogged. Replace the system filter element. The required set pressure can not be reached. The inlet pressure to the dome regulator or to the pilot regulator is not high enough. Make sure that the inlet pressure to the dome regulator and to the pilot regulator is sufficient. The outlet pressure rises too much when going from a dynamic to a static situation. There is too much flow in the dynamic situation. A larger regulator is required. Check the specific application data with the flow curves in our product literature, if available. The outlet pressure does not drop if the pressure in the dome is lowered. The valve is sticking. Replace the valve assembly. The outlet pressure has changed without adjusting the dome pressure. Changes to the inlet pressure will result in changes to the outlet pressure. Maintain a constant inlet pressure to the regulator. See section operation about dependency.

Warranty Information Swagelok products are backed by The Swagelok Limited Lifetime Warranty. For a copy, visit swagelok.com or contact your authorized Swagelok representative. For additional information, see www.swagelok.com. Caution: Do not mix or interchange parts with those of other manufacturers. Swagelok, Snoop Swagelok Company 2010 Swagelok Company December 2010, R0 MS-CRD-0184