Oil Well Potential Test, Completion or Recompletion Report, and Log

Similar documents
Oil Well Potential Test, Completion or Recompletion Report, and Log

Oil Well Potential Test, Completion or Recompletion Report, and Log

RAILROAD COMMISSION OF TEXAS OIL WELL POTENTIAL TEST, COMPLETION OR RECOMPLETION REPORT, AND LOG

RAILROAD COMMISSION OF TEXAS OIL WELL POTENTIAL TEST, COMPLETION OR RECOMPLETION REPORT, AND LOG

RAILROAD COMMISSION OF TEXAS OIL WELL POTENTIAL TEST, COMPLETION OR RECOMPLETION REPORT, AND LOG

RAILROAD COMMISSION OF TEXAS OIL WELL POTENTIAL TEST, COMPLETION OR RECOMPLETION REPORT, AND LOG

RAILROAD COMMISSION OF TEXAS OIL WELL POTENTIAL TEST, COMPLETION OR RECOMPLETION REPORT, AND LOG

INSTRUCTIONS FOR COMPLETING FORM H-9 STATEWIDE RULE 36 CERTIFICATE OF COMPLIANCE

Railroad Commission of Texas

Colorado Oil and Gas Conservation Commission

Colorado Oil and Gas Conservation Commission (COGCC) Completed Interval Report, Form 5A Data Field Definitions

Disposal/Injection Well Pressure Test Report (H-5)

Railroad Commission of Texas. Chairman Barry T. Smitherman Commissioner David Porter Commissioner Christi Craddick

OIL/GAS WELL COMPLETION REPORT. Well Name and Number Surveyed elevation (feet): KB GL

ENDEAVOR ENERGY RESOURCES

Oklahoma Corporation Commission Oil & Gas Conservation Division Post Office Box Oklahoma City, Oklahoma Rule 165:

Statewide Rule 36: H2S

High Cost Gas Statewide Rule 101 (Tight Formations)

FORGE Energy UL 21 Freedom 1 API Number:

Texas Administrative Code

D & V Oil Co. LP. Daily Completion Report - University CN A #6 API # /23/2016. Perfs ' ' Activity :

Reclassification and Recompletion

FREQUENTLY ASKED QUESTIONS

APPENDIX A1 - Drilling and completion work programme

W I L D W E L L C O N T R O L FLUIDS

Mobeetie Resource Dev LLC EXAMINER S REPORT AND RECOMMENDATION STATEMENT OF THE CASE

Blowout during Workover Operation A case study Narration by: Tarsem Singh & Arvind Jain, OISD

Deliquification Short Stories

OIL AND GAS DOCKET NO

OIL AND GAS DOCKET NO

Friday 14 th September, 2012

Kerry A. Pollard Texstar Midstream Utility, LP Gallon E. Gray Phillip Zamzow EXAMINER S REPORT AND RECOMMENDATION STATEMENT OF THE CASE

Abandonment Program for Paramount Fort Liard F 36

A Longer Lasting Flowing Gas Well

Drilling Morning Report

Advanced Applications of Wireline Cased-Hole Formation Testers. Adriaan Gisolf, Vladislav Achourov, Mario Ardila, Schlumberger

RULE 36 & H 2 S SAFETY

RULES OF THE OIL AND GAS PROGRAM DIVISION OF WATER RESOURCES CHAPTER DRILLING WELLS TABLE OF CONTENTS

WELL NO: BJN-8. Lower master valve

PHE KE30-A8 WORKOVER PROGRAM

Representing EXAMINERS REPORT AND PROPOSAL FOR DECISION STATEMENT OF THE CASE

Statewide Rule 36: Operations in Hydrogen Sulfide Areas. Statewide Rule 32: Flaring/Venting of Produced Gas. May 5, 2015

Directive 059: Well Drilling and Completion Data Filing Requirements

Chapter 5 HORIZONTAL DRILLING

Representing EXAMINERS REPORT AND PROPOSAL FOR DECISION STATEMENT OF THE CASE

Hydro-Mech Bridge Plug

W I L D W E L L C O N T R O L PRESSURE BASICS AND CONCEPTS

Enbridge G & P (East Texas) LP EXAMINER S REPORT AND PROPOSAL FOR DECISION STATEMENT OF THE CASE

Form MMS 123A1123S Electronic Version. Application. We have incorrect pressure tests for the annulars on subject ABP The ABP shows we

Worked Questions and Answers

Casing Design. Casing Design. By Dr. Khaled El-shreef

FRAC FLUIDS AND WATER USAGE Evaluating The Commercial Viability and Success In Using Water-Free Fracs

Squeeze Cementing. Brett W. Williams Cementing Technical Advisor January 2016 Tulsa API Meeting

Coal Bed Methane (CBM) Permeability Testing

EXAMINER S REPORT AND RECOMMENDATION STATEMENT OF THE CASE

Intermittent Gas Lift Utilizing a Pilot Valve

Oil, Gas and Salt Resources of Ontario

Casing and Cementing Requirements

PROPOSED NEW SUB- CODE 1 RIG UP AND TEAR. Possibly Fits into Existing Code. 7/26/2018 Review PROPOSED NEW CODE EXISTING OPERATION

Coiled Tubing string Fatigue Management in High Pressure Milling Operation- Case Study

Details for PDQ Operatorr s Production and Disposition Volumes by Lease by Month

CHDT Cased Hole Dynamics Tester. Pressure testing and sampling in cased wells

BENEDUM (DEVONIAN, GAS) API # UPTON COUNTY, TX DRILLING PERMIT # DAILY REPORTS

THE FIELD RULES FOR THE EAGLEVILLE (EAGLE FORD-2) FIELD, DE WITT, KARNES, LAVACA AND LIVE OAK COUNTIES, TEXAS

Simplified Start-Up Checklist For Fully-Pressurized Seasonal Systems

Captains Meeting 2009 Introduction to Well Testing- Expro. Edwin Schoorl

Understanding pressure and pressure

BLACK HILLS PLATEAU PRODUCTION COMPANY

H. H. HOWELL, INC. Inland Ocean Bevans #1 Bevans & Wildcat Field Menard County, Texas

1. UPDATE 12/12/2014: What wells are regulated under the MIA Program? Must they be drilled, stimulated, and completed? Must they be in production?

SPE MS. Copyright 2015, Society of Petroleum Engineers

Completions & Workovers Module 1.9

Situated 250km from Muscat in

Extended leak off testing

Dual Gas Lift Well Analysis Using WellTracer

DEPARTMENT OF ENVIRONMENTAL PROTECTION Office of Oil and Gas Management

Appalachian Basin Gas Well. Marietta College, Marietta, Ohio June 7-8, Development. Robert McKee, P.E. Design Engineer Multi Products Company

Innovating Gas-Lift for Life of Well Artificial Lift Solution. The Unconventional Solution!

Practice Exam IADC WellSharp Driller and Supervisor

North Dakota Petroleum Council Re-stimulation Initiative

Well Testing Plan. New York Marginal Well Study. Introduction. I. Tests to be Conducted. II. Testing Procedures

PTRT 1471: Exploration and Production I. Chapter 6: Drilling and Well Completion

DUO-SQUEEZE H LCM Mixing Tables and Operating Procedures

LIMITED ENTRY CLUSTER PERFORATING SYSTEM IMPROVES FRACTURING EFFICIENCY IN HORIZONTAL WELLS

Float Equipment TYPE 925/926

Terrace Petroleum Corporation Cunning Wolf UL No. 602H, 1980 FNL and 467 FWL Section 6, Block 23, ULS Pecos County, Texas

MIA Training Example (Catalano 2H)

Perforation Design for Well Stimulation. R. D. Barree Barree & Associates LLC

SUPPLEMENT Well Control for Drilling Operations Workover & Completion for Drillers Core Curriculum and Related Learning Objectives

DEPARTMENT OF ENVIRONMENTAL QUALITY OFFICE OF OIL, GAS, AND MINERALS OIL AND GAS OPERATIONS

Wellwork Chronological Regulatory Report

THE STATE OIL AND GAS BOARD OF MISSISSIPPI. RE: EMERGENCY PETITION OF FOREST OIL him o 4 jogg

WELL SUSPENSION AND ABANDONMENT GUIDELINES AND INTERPRETATION NOTES OFFICE OF THE REGULATOR OF OIL AND GAS OPERATIONS

Wellwork Chronological Regulatory Report

Perforating Options Currently Available in Horizontal Shale Oil and Gas Wells. Kerry Daly, Global BD Manager- DST TCP

Tuesday 4 th September, 2012

BC Well Testing & Reporting Requirements. Reservoir Engineering

BEFORE THE STATE OIL AND GAS BOARD OF MISSISSIPPI. i RE: PETITION OF ALLEN OPERATING COMPANY nfccord

Development of a Subsurface Mudline Packer to Reduce Risk of Flow after Cementing and Sustained Casing Pressure, While Providing a Platform for P&A.

INTERMEDIATE CASING SELECTION FOR COLLAPSE, BURST AND AXIAL DESIGN FACTOR LOADS EXERCISE

Transcription:

Tracking No.: 16947 Status: Submitted RAILROAD COMMISSION OF TEAS Oil and Gas Division API No. 42- Oil Well Potential Test, Completion or Recompletion Report, and Log 1. FIELD NAME (as per RRC Records or Wildcat) 2. LEASE NAME UNIVERSITY BLOCK 9 (DEVONIAN) UNIVERSITY BLOCK 9 3. OPERATOR'S NAME (Exactly as shown on Form P-5, Organization Report) RRC Operator No. TO ENERGY INC. 945936 4. ADDRESS 200 N LORAINE ST STE 800 MIDLAND, T 79701-0000 5. If Operator has changed within last 60 days, name former operator This facsimile W-2 was generated electronically from data submitted to the RRC. 6a. Location (Section, Block, and Survey) 6b. Distance and direction to nearest town in this county. 10, 9, UNIVERSITY LAND 14 MILES SW FROM ANDREWS, T 12. If workover or reclass, give former field (with reservoir) & Gas ID or oil lease no. GAS ID or FIELD & RESERVOIR OIL LEASE # UNIVERSITY BLOCK 9 (WOLFCAMP) 15046 003-02915 Oil-0 Gas-G Oil Well 13. Type of electric or other log run 14. Completion or recompletion date GR/CCL/CBL 06/01/2011 7. RRC District No. 08 8. RRC Lease No. 39152 9. Well No. 6AO 10. County of well site ANDREWS 11. Purpose of filing Initial Potential Retest Reclass Well record only (Explain In remarks) 6AO Well # SECTION I- POTENTIAL TEST DATA IMPORTANT: Test should be for 24 hours unless otherwise specified infield rules. 15. Date of test 16. No. of hours tested 17. Production method (Flowing, Gas Lift, Jetting, Pumping- Size & Type of pump) 18. Choke size 06/08/2011 24 Pumping 19. Production during Test Period 20. Calculated 24- Hour Rate Oil - BBLS Gas - MCF Water - BBLS Gas - Oil Ratio 34.0 51 67 1500 Oil - BBLS Gas - MCF Water - BBLS Oil Gravity-API-60 o 34.0 51 67 44.06 Flowing Tubing Pressure Casing Pressure 21. Was swab used during this test? 22. Oil produced prior to test (New & Reworked wells) 23. Injection Gas-Oil Ratio Yes No 37.0 REMARKS: RECOMPLETED TO UNIVERSITY BLOCK 9 (DEVONIAN) FIELD. WELL IS CURRENTLY ON PRORATION SCHEDULE AS UNIVERSITY BLK 9/WOLFCAMP/UNIT (RRC 15046), WELL #6AO IN THE UNIVERSITY BLOCK 9 (WOLFCAMP) FIELD. CHANGING WELL NAME TO UNIVERSITY BLOCK 9 #6AO. PSI PSI INSTRUCTIONS: File an original and one copy of the completed FormW-2 in the appropriate RRC District Office within 30 days after completing a well and within 10 days after a potential test. If an operator does not properly report the results of a potential test within the 10-day period, the effective date of the allowable assigned to the well will not extend back more than 10 days before the W-2 was received in the District Office. (Statewide Rules 16 and 51) To report a completion or recompletion, fill in both sides of this form. To report a retest, fill in only the front side. WELL TESTERS CERTIFICATION I declare under penalties prescribed in Sec. 91.143, Texas Natural Resources Code, that I conducted or supervised this test by observation of (a) meter readings or (b) the top and bottom gauges of each tank into which production was run during the test. I further certify that the potential test data shown above is true, correct, and complete, to the best of my knowledge. Signature: Well Tester Name of Company RRC Representative OPERATOR'S CERTIFICATION I declare under penalties prescribed in Sec. 91.143, Texas Natural Resources Code, that I am authorized to make this report, that this report was prepared by me or under my supervision and direction, and that data and facts stated therein are true, correct and complete, to the best of my knowledge. TO ENERGY INC. Regulatory Type or printed name of operator's representative Title of Person (432) 620-6709 05/18/2012 Sherry Pack Telephone: Area Code Number Month Day Year Signature

SECTION III 24. Type of Completion DATA ON WELL COMPLETION AND LOG (Not Required on Retest) New Well Deepening Plug Back Other 26. Notice of Intention to Drill this well was filed in Name of TO ENERGY INC. 27. Number of producing wells on this lease in this field (reservoir) including this well 62 4819.5 29. Date Plug Back, Deepening, Workover or Drilling Operations: Commenced Completed 31. Location of well, relative to nearest lease boundaries 1980.0 Feet From North Line and 660.0 East Line of the UNIVERSITY BLOCK 9 Other DATE 01/21/2011 32. Elevation (DF. RKB, RT. GR ETC.) 33. Was directional survey made other than inclination (Form W-12)? Yes 3165 GL No 34. Top of Pay 35. Total Depth 36. P. B. Depth 10460 10600 10600 38. Is well multiple completion? Yes No 28. Total number of acres in this lease 12/08/2010 06/01/2011 300.0 30. Distance to nearest well, Same Lease &Reservoir 37. Surface Casing Determined by 39. If multiple completion, list all reservoir names (completions in this well) and Oil Lease or Gas ID No. FIELD & RESERVOIR N/A 40. Intervals Drilled by: 43. Rotary Tools Cable Tools 41. Name of Drilling Contractor UNKNOWN Field Rules CASING RECORD (Report All Strings Set in Well) 25. Permit to Drill, Plug Back or Deepen Rule 37 Exception Water Injection Permit Salt Water Disposal Permit Recommendation of T.D.W.R. Railroad Commission (Special) GAS ID or OIL LEASE # 05/30/1960 Oil-0 Gas-G Dt. of Letter Dt. of Letter 708746 CASE NO. F-1620 Well # 42. Is Cementing Affidavit Attached? Yes CASING SIZE WT #/FT. DEPTH SET MULTISTAGE TYPE & AMOUNT HOLE SIZE TOP OF SLURRY VOL. TOOL DEPTH CEMENT (sacks) CEMENT cu. ft. 13 3/8 48.0 406 UNKNOWN 400 17 1/2 SURFACE 0.0 9 5/8 36.0 4430 UNKNOWN 2500 12 1/4 SURFACE 0.0 7 23.0 29.0 10577 UNKNOWN 800 8 3/4 7560 TS 0.0 Feet from Lease No 44. LINER RECORD Size Top Bottom Sacks Cement Screen 5 1/2 0 10552 400 CEMEENTED W/400 S TOC 3180' (CBL) 45. TUBING RECORD 46. Producing Interval (this completion) Indicate depth of perforation or open hole S i ze D ep th S et P acker S et F rom 1 0 460 To 1 0 538 2 7 /8 1 0583 F rom 1 0 57 7 To 1 0600 OH F rom F rom To To 47. ACID, SHOT, FRACTURE, CEMENT SQUEEZE. ETC. Depth Interval Amount and Kind of Material Used 10460.0 10538.0 PERFED DEVONIAN W/ 1 JSPF 52 SHOTS. ACIDIZED W/25,000 G 15% HCL ACID 8475.0 8546.0 CMNT SQUEEZE W/ 250 SS CL H CEMENT 10564.0 10600.0 ACIDIZED OH W/12,500 G 15% HCL ACID 48. FORMATION RECORD (LIST DEPTHS OF PRINCIPAL GEOLOGICAL MARKERS AND FORMATION TOPS) Formations Depth Formations WOLFCAMP 8465.0 DEVONIAN 10444.0 Depth REMARKS: SQUEEZE WOLFCAMP PERFS. SET 5 1/2 LINER. DO TO NEW PBTD 10600'. PERF DEVONIAN. WELL DEEPENED TO 10560'.