Medical Gas Solutions

Similar documents
LOKRING Stainless Steel (SS40) and Carbon Steel (CS) Pipe Fittings Table of Contents

CSA Sample Draw Aspirator Adapter Operator s Manual

RK-IR Sample Draw Aspirator Adapter Operator s Manual

Forged Brass Bellows Valves

D Series Air and Water Kit Part# 02550

CHEMICAL INDUCTION KIT (Pt.No Issue 6, October 2015)

J Air and Water Kit Instructions Part# 02584

RK LEL Sample Draw Aspirator Adapter Operator s Manual

Instruction Manual LIMITED 1 YEAR WARRANTY. Hydraulic Punch Driver Read this material before using this product.

Compact Triple Cabinet Outlet Station Model Installation and Operating Instructions

SIX R (P ) AND SEVEN R (P ) POSITION CYLINDERS Service Information

Cylinder Tilt Saddle Instruction Manual

PACKER OPERATING PROCEDURES

INSTALLATION MANUAL Matheson Tri-Gas Cabinet Enclosures

MODEL CALIBRATION GAS DELIVERY SYSTEM

3800 SERIES END SUCTION PUMP REPAIR PARTS INDEX. Model Model 3804

INSTALLATION INSTRUCTIONS AT-SERIES ANCHOR ASSEMBLY PART NUMBER: F-04CAJP 450 LB. [204kg] MAXIMUM CAPACITY (PRO POOL LIFT)

Model Portable Eyewash

Series 8500 Expansion Compensators. Catalog 674H

Pressure Relief Valve Instruction Manual

HAYWARD FLOW CONTROL Series PBV Back Pressure Valve and Series RPV Pressure Relief Valve INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS

ROPV R40 E Series User Manual

NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE

EQUIPMENT OPERATION MANUAL. Loctite Dispense Valve Manual

HAYWARD FLOW CONTROL TFS SERIES FLOW METER INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

SDS -Series 4C-D201/-D202 Supplemental Drying System User s Manual

Sterile Visual Flow Indicator

HoverJack. Air Patient Lift. Equipment Manual. From HoverTech International. Issued: June 1,

ULTRA HIGH PRESSURE PAINT GRATE CLEANER FCT-JS OPERATION AND MAINTENANCE MANUAL

TactAir PCP Fill Kit/Adapter. Operation Manual

INSTALLATION & MAINTENANCE INSTRUCTIONS

Model C Pipe Line Strainer 6, 8 & 10 Inch (DN150, DN200 & DN250) 250 psi (17,2) General Description. Technical Data. Page of 6 MAY, 2006 TFP1644

Eliminating Medical Gas Shutdowns for 10 years

PRESSURE REDUCING STATION INSTALLATION, OPERATIONS & MAINTENANCE MANUAL

CF-SERIES HIGH FLOW REGULATORS

3" UC Ultra-Chuck Durable Lightweight Air Inflated Bladder Chuck Operation/Repair Manual. (76.2 mm) DOUBLE E COMPANY, INC.

Hot Tapping Machine. OPERATIONS MANUAL and OPERATING INSTRUCTIONS

UNIVERSAL MASK TEST SYSTEM

92831 TEL: (714) FAX:

92831 TEL: (714) FAX:

INSTRUCTIONS FOR MODELS SG3897 AND SG3898 CROSS PURGE ASSEMBLIES

INSTRUCTION MANUAL GAS TRAK

OPERATION / 3Z9305G 1:1 RATIO TRITON / Spray Packages / / / List of Models, page 2 / / / 100 psi (7 bar, 0.7 MPa) Maximum Working Pressure

SSFU SUPER SPRAYFAST UNIVERSAL ADHESIVE APPLICATOR

HYDROVEX TTT Membrane Flow Regulator

Compact Triple Cabinet Outlet Station Model B Installation and Operating Instructions

PC1131 Electric Air Compressor

High Pressure Inlet Kits for CONCOA BlendMites and BlendMasters

APCO ASU-SCAV & ASU-CAV SINGLE BODY COMBINATION AIR VALVES

Operating Instruction Manual for Liquid Nitrogen Containers. CRY/CRYC Series. Hagavish st. Israel Tel: , Fax:

Adjustable. Unloader Valve. O&M Manual. Part #

FLANGED TWO-PIECE BALL VALVES

Model ASSEMBLY and OPERATING INSTRUCTIONS

4-in-1 Professional Inflator Kit

ALL-PURPOSE Low and Medium Pressure TUBE FITTINGS

Hygienic Bubble Trap Installation and Operations Manual

TECHNICAL DATA MAINTENANCE AIR COMPRESSOR MODEL G-1

PRICE GROUP DISCOUNT MULTIPLIER DESCRIPTION 05 PVC INSERT FITTINGS PRODUCTS PRICE LIST PVC INSERT PRESSURE FITTINGS

ASDX Series Silicon Pressure Sensors

RAM 4021 Operation Manual

User Manual. ECC-Opto-Gas. Release Electrochemical test cell EL-CELL GmbH

URC Voltage Sensor SEN-VOLT for use with MRX units containing sensor ports

PCS 340 Core Saturator : 115 Volt : 230 Volt. Instruction Manual

FLOW CONTROL & AIR PILOT SWITCH VALVES

SC HYDRAULIC ENGINEERING CORPORATION

HAYWARD FLOW CONTROL FLV SERIES, PVC/CPVC FILTER VESSEL INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

1 Exam Prep NFPA 99 Health Care Facilities Questions and Answers (Plumbing Contractor)

KJ4000 Operating Instructions & Parts Manual NSN

S PRESSURE REGULATOR

Instruction Manual Model Borehole Pressure Cell

TOP VALVE. Pat. #5,857,486 & 5,944,050. High Temperature: max. 300 F (149 C) Back Pressure And Pressure Relief Valves. Instruction Manual

Yoke Block Instruction Manual

Acid- Rite ph Adjustment System 2500 by Axiall, a Westlake Company

EQUIPMENT Operation Manual. Loctite Stainless Steel Poppet Valve Part Number

TL-12 FLUSH TANK. Manual Ref. # MN-??? Polyurethane Machinery Corp. REVISION 1.0

PRESSURE COMPARATOR 10000PSI 700bar. Operator Instructions CRYSTAL. engineering corporation

Nitrous Oxide / Oxygen FLOOR MOUNTED OUTLET STATION Installation and Instructions

BS Series Basket Strainer

This document to be used with Hurley traditional Davits

Model 9201E Tempered Water Blending System

Color/Catalyst Dispense Valves

453 Series Steam Heated Vaporizing Regulator

WEATHERIZING INSTRUCTIONS

INSTALLATION / OPERATION / MAINTENANCE INSTRUCTION

Circular Sight Windows

Please Do Not Return This Product To The Store!

Gemini Owner s Manual

INSTRUCTIONS FOR MODEL SG6500 GAS HEATERS

AND OPERATION INSTRUCTIONS

Back Pressure Regulator

WATER HEATER THERMAL EXPANSION TANKS Owner s Manual. Safety Instructions Installation Maintenance Warranty. Models: 2-5 Gallon Capacity

E8AA. Pressure Sensor of Stainless Steel Construction Is Ideal for a Wide Range of Applications. Pressure Sensor (Stainless Steel Diaphragm)

STC 2KS/2KD Series Stainless Steel Angle Seat Valve

SINGLE STAGE ULTRA-HIGH PRESSURE REDUCING REGULATOR INSTALLATION AND OPERATION INSTRUCTIONS. Certified ISO 9001

FLANGED TWO-PIECE BALL VALVES

OPERATION. Zinc Sprayer. For Maximum Working Pressure see page 2. Rev. E

Model No Product Name Handpiece Only Complete System

TOP VALVE. Pat. #5,857,486 & 5,944,050. Mid-Range Pressure PSIG Back Pressure and Pressure Relief Valves. Instruction Manual

4 and 8 Station PDS Control Installation & Operators Manual

Yoke Block Instruction Manual

Transcription:

WHN YOU ND from OKRING okring Technology, C offers a patented, permanent, axially swaged tube fitting. This technology for medical gas applications has been approved by NFP 99-005 (Paragraph 5..0.7 (4)). Imagine being able to shut down your medical gas system and within minutes being able to install a tie-in, a tee for future expansion or to cap off a line for renovation. Medical gas tie-ins can be installed as fast as you can drain the lines. Simply bleed the medical gas or vacuum line, cut and clean the tubing, and install a OKRING fitting. It takes less than five minutes to install a permanent, leak-tight fitting. Since no brazing is necessary, no expensive nitrogen NF purge is required. Without brazing, no particulate is created during installation. Gas lines go back into service as fast as the credentialed Medical Gas Verifier can document proper concentrations. okring Medical Gas s... The installation of OKRING Medical Gas fittings takes minimal time and there is less patient disruption due to noise and brazing. okring installation is a cold braze alternative. There is no hot work, no burn permits, and no fire watches necessary. In addition, the speed of the OKRING installation reduces system down-time and the additional costs associated with contract labor and overtime staffing. s are cleaned for oxygen service in sizes 3/8 through. simple hand held tool is all that is necessary. The top photo on the right shows an installer attaching a ½ OKRING coupling to a pre-fabricated, vacuum line tie-in. The oxygen tie-in installation in the middle & bottom photos uses OKRING ½ couplings on Type copper tubing. The cost of OKRING Medical Gas s is considerably less than the overall cost of other special fittings for medical gas tie-ins. short training course is all that is required for contractors with NSI/SS 600 installer certification. okring Technology has been used by the Marine, Biotech, utomotive, Power Generation, Chemical Processing and Railroad industries worldwide since 989.

dvantages of OKRING s No brazing necessary No nitrogen NF purge required No danger of particulate formation No danger of melting or burning of ambient materials in the area (such as adjacent wiring and pneumatic lines) No burn permits needed No fire brigade standby necessary No shutdown of smoke or fire sensors in the area No cooling of brazed joints -- immediate usage following leak test Minimal patient disruption Special configurations available This outside installation used OKRING couplings to connect existing medical gas lines to new lines for hospital expansion. This installation included ¾ size for nitrogen and nitrous oxide. The oxygen line was ½ size on Type copper. The total installation time for the three fittings was 0 minutes. OKRING s SP (lastic Strain Preload) Technology The leak-free seal is the result of OKRING s SP installation where the axial movement of the OKRING driver over the body swages the body onto the tube s surface. This compresses the tube wall first elastically and then plastically. BTTR CONNCTION The tube wall resists this swaging action, generating high unit compressive loads at the contact points between narrow sealing lands inside the fitting body and the tube surface. These contact stresses are sufficiently high to plastically yield the tube surface under the sealing lands, forming a 360 circumferential, permanent, metal-to-metal seal between the tube and fitting body. The driver, which experiences a small increase in diameter (elastic strain) during installation, exerts an elastic, radial preload on the metallic seals for the life of the connection. Pressure Testing This test was performed on ½ Type K copper tubing. s shown, the copper tubing burst at 300 psi while the fitting remained intact. Nominal () Tube OD 3/8 (T06) / () Qualified Wall Thickness K Qualified Wall Thickness Qualified Wall Thickness M Wall Pressure Rating (PSI) Wall Pressure Rating (PSI) Wall Pressure Rating (PSI) 0.500 0.049 946 0.035 34 0.05 98 0.65 0.049 534 0.040 4 0.08 850 (T0) 0.750 0.049 66 0.04 086 - - (T) 0.875 0.065 466 0.045 00 0.03 70 (T6).5 0.065 6 0.050 850 0.035 580 ¼ (T0).375 0.065 94 0.055 755 0.04 58 ½ (T4).65 0.07 850 0.060 70 0.049 569 (T3).5 0.083 747 0.070 65 0.058 54 Pressure rating should be derated at elevated temperature. s meet 000 F integrity test. See specification FS- for details. Temperature rating -45 F to 400 F

WHN YOU ND General Information Nominal () Tube O.D. Qualified Wall Thickness Insertion Depth Post-Install, K//M Insertion Depth PreInstall, 3/8 (T06) 0.500 / () 0.65 (T0) (T) Outside Diameter, B C Minimum Straight Run Before Obstruction,.049 /.035/.05.3 0.89.68.049/.040 /.08.3 0.89.68 0.750.049/.04 / --.4.95 0.875.065/.045 /.03.55..04 (T6).5.065/.050 /.035.04.46.63 ¼ (T0).375.065/.055 /.04.3.66.86.8 ½ (T4).65.07/.060 /.049.64.90. 3.0 (T3).5.083/.070 /.058 3.44.47.88 4.0. ll dimensions are in inches.., B,C & are applicable to all fittings of the same size within this catalog. 3. For use on copper tube per S B89, type K and wall, and drawn for copper tube per S B88 type K and wall. 4. For tooling dimensions refer to proper catalog or www.lokring.com 5. Coupling thru-bore design permits tube to pass completely through. 6. material 360 Brass as per S B6. 7. s are cleaned to CG G-4. standard. (OC = Oxygen Clean) 8. s are approved by NFP 99-005 and meet or exceed the design requirements of brazed fittings. 9. CD files in.dwg file format are available for most configurations. 0. ll dimensions are reference only and subject to change.. Due to variation in heat affected zones (HZ), okring fittings should be installed at least 6 from a brazed joint.. s individually bagged after cleaning Couplings 3/8 T06.47 / T0 Take-Out, N/.47 N/.8 N/ T 3. N/ T6 4.07 N/ - /4 T0 4.6.86 N/ - / T4 5.8. N/ T3 6.88.88 N/ -CP- ll dimensions are for reference only and are subject to change. Reducers 3 -TYY Take-Out, xx yy / - 3/8 - T06.47 0.4 - / T0 -.84 0.9 - / T - 3.7 0.38 - T - T0 3.5 0.9 - / T6 -.47 0.4 - T6 - T 3.95 0.36 -/4 - T0 - T6 4.6 0.7.86 -/ - -/4 T4 - T0 5.7 0.3..86 - -/ T3 - T4 6.58 0.5.88. ll dimensions are for reference only and are subject to change. -RD--TYY

BTTR CONNCTION Caps -CP- Take-Out, T06.47 0.4 3/8 - CP - / - CP -.47 0.4 - CP - T0.65 0.4 - CP - T.76 0. - CP - T6.33 0.9 -/4 - CP - T0.6.86 0.3 - / - CP - T4.98. 0.34 - CP - T3 3.86.88 0.4 ll dimensions are for reference only and are subject to change. 90 lbows -90-FRG- Take-Out, / - 90 -.79.73.05-90 - T0 4.09 4.8.7-90 - T 3.53 3.4.6-90 - T6 4.0 3.99 ll dimensions are for reference only and are subject to change. Tees -T-FRG- Part ength Part ength TakeOut, / -T-FRG- 4.57.99.05 -T-FRG- T0 7.6 4.8.7 -T-FRG- T.79.73 0.7.05 -T-FRG- T6 6.46 3.99.39 ll dimensions are for reference only and are subject to change. 4

WHN YOU ND Gage Port Caps Take-Out 3/8 - GCP - T06.64 0.43 / - GCP -.64 0.4 - GCP - T0.8 0.40 - GCP - T.96 0.4 - GCP - T6.40 0.36 - /4 - GCP - T0.68.86 0.37 - / - GCP - T4 3.00. 0.37 - GCP - T3 3.8.88 0.37 -GCP- Thread size is /8-7-FPT ll dimensions are for reference only and subject to change. Gage Port Couplings / 3.78 T0 - /4 Take-Out 0.75 5.45 0.70 T 4.5 0.75 T6 4.4 0.60 T0 6.0.86 0.68 - / T4 7.07. 0.60 T3 7.09.88 0.75 -GCP- Thread size is /8-7-FPT ll dimensions are for reference only and subject to change. Tooling Tooling consists of two kit sizes supplied with gauges and adjustable inserts. MTK0- is used for 3/8, /, and tubing. MTK50- works with, ¼, ½ and tubing. 5

To install a OKRING fitting, a tool head with inserts, multipurpose gage, hydraulic pump, and hydraulic hose are needed. Tools, inserts, and gages come packaged either as: Multiple tool kits designed for installing multiple size fittings with one tool (MTK Series) Contact your authorized OKRING distributor for ordering details How to Select Tooling Tool Selection for Brass Tube s Tool 3/8 / - /4 - / The shaded cells show which size tool can install which size fitting. Medical Gas Training Classes and Certification are required to install okring fittings. TRINING IS VIB THROUGH YOUR OC OKRING DISTRIBUTOR www.lokring.com NOT: Tool rentals may be available through your local okring Distributor BTTR CONNCTION OKRING TCHNOOGY STNDRD PRODUCT WRRNTY okring warrants that goods delivered hereunder shall be free from defects in material and workmanship under normal use and service for a period of one () year from shipment. If during such one () year period,.. 3. okring is notified promptly upon discovery of any defect in the goods, including a detailed description of such defect. okring is afforded the opportunity to inspect such goods at the installation site prior to any attempt to repair or retrofit. If requested by okring, Customer returns such goods to okring for further examination (FOB destination); and upon examination of such, okring determines that such goods were defective and such defects were not caused by accident, abuse, misuse, neglect, alteration, improper installation, repair or alteration (other than at the specific direction of okring), improper testing or use contrary to instruction of okring, then within a reasonable time. okring shall at its sole option credit the customer for such goods. ny goods replaced under this warranty shall be returned to the customer, transportation charges prepaid, and okring will reimburse the customer for any transportation charges incurred under section () above. The performance of this warranty does not extend the warranty period of any goods beyond the period applicable to the goods originally delivered. In no event shall okring be liable for claims for any other damages whatsoever (whether direct, immediate, foreseeable, consequential or special) suffered by Buyer or anyone else arising out of any breach by okring. This express warranty is in lieu of and excludes all other warranties, guarantees, and/or representations, expressed or implied. System design and system safety are the ultimate responsibilities of the end-user. Consideration to system function, compatibility, product ratings, as well as other factors, must be given to ensure proper product selection and function. ll information in this catalog has been compiled with regard to accuracy; however, the most up to date information should be verified before use of the product. okring reserves the right to change product dimensions, ratings, or other information. 0 6

okring Technology C 0 Printed 0/ - Part #9070064