Supratec von-drais-straße 7 D Simmern/Hunsrück Fon: *49 ( ) Fax: *49 ( )

Similar documents
Supratec. MEMBRANE-PLATE-DIFFUSER For fine bubble aeration of liquids BELÜFTUNGSTECHNIK UMWELT- & VERFAHRENSTECHNIK SERVICE & WARTUNG

Supratec. von-drais-straße 7 D Simmern/Hunsrück Fon: +49 ( 67 61) Fax: +49 ( 67 61)

Supratec Gesellschaft für Umweltund Verfahrenstechnik mbh OXYFLEX - M T / M T M E M B R A N E D I S C D I F F U S ER AERATION TECHNOLOGY

Supratec AERATION TECHNOLOGY. von-drais-straße 7 D Simmern / Hunsrück. tel.: / fax: /

aeration and mixing systems

Disc diffuser ELASTOX -T

Panel diffuser ELASTOX -P

RAUBIOXON PLUS Pipe Aerator

FINE BUBBLE DISC DIFFUSER

Operating instructions - Translation of the original -

Pressure Reducing Valve DMV 750

DICTATOR "DIREKT" Gate Closer

Instructions for Use. Plug connection for medical gas and vacuum acc. to DIN / 2004 DIN EN ISO

Pressure Reducing Valve

Operating instructions - Translation of the original -

Pressure Reducing Valve DMV 755

Armatures for analytical probes

Instruction presentation Special valves

Pressure relief valve DHV 716 set range: 0,5-10,0 bar

Pressure Reducing Valve DMV 750 set range: bar

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

FORMIC ACID DOSING STATION

AVK SERIES 601, 602, 603 & 605 UNIVERSAL COUPLINGS, ADAPTORS & END CAPS INSTALLATION, OPERATION & MAINTENANCE MANUAL

Technical Bulletin 161. How Deep Can I Design my Aeration Tanks? by:

Valves. Diaphragm shut-off valves, kidney-type

RAUBIOXON AND RAUBIOFLEX AERATOR SYSTEMS TECHNICAL INFORMATION

OPERATING MANUAL CHEMTRAC 840M MANUAL RETRACTABLE PROCESS HOLDER

400V 50Hz. Tsurumi TRN. Submersible aerator. Auto-suction submersible aerator for communal and industrial waste water clearance and treatment.

Pressure relief valve DHV 725 set range: 0,2-10,0 bar

Pressure relief valve DHV 712 DN 65-80: 0,5-10 bar, DN : 0,3-4 bar, DN 100: 0,5-6 bar

Technical Bulletin 160. Maximum Air Pressure for Diffusers. by:

Mounting and operating instructions EB 2530 EN. Self-operated Pressure Regulator. Pressure Reducing Valve Type M 44-2

OXYGEN and SYSTEM OXY

Expert Hydrostatic Level Transmitters

Type BBS-03, BBS-05, BBS-06, BBS-25

Float operated valve TYPE (SWDS)

DICTATOR "DIREKT" Gate Closer

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25

Pressure Relief Valve DHV 718

PRS(TC)4,8 USER MANUAL. Read the complete manual before installing and using the regulator.

Operating instruction

Mounting and Operating Instructions EB EN. Type Supply Pressure Regulator. with increased air capacity

TA-COMPACT-P. Combined control & balancing valves for small terminal units Pressure independent balancing and control valve (PIBCV)

Operating instructions - Translation of the original -

better measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars.

FITTINGS AND VALVES Düker Plunger Valve RKV Type 7015 Professional control of flow rates, reservoir levels and pressures Safe, hygienic and durable!

Siphon vessel / Priming aid

Gas Pressure Regulator HON 300

Pressure Reducing Valve DMV 755 set range: 1,0-9,0 bar

Self-operated Pressure Regulators for special applications

OPTIPOW 105 OPTIPOW 105 ; MAIN PARTS. Our Ref: PSE, Bernt Andersson

Pressure Equalising Valves Model , for Differential Pressure Gauges

INSTALLATION INSTRUCTIONS FOR SSI WIDEBAND DIFFUSER

Operating instructions - Translation of the original -

Johnston Invar Coupling Johnston Invar Coupling

BTV. Internally threaded 2-way control valve. Flow characteristics. Function

INSTALLATION, OPERATION AND MAINTENANCE GUIDE

Measurement of Low GAS & Liquid Flows

TBV-CM. Combined control & balancing valves for small terminal units For modulating control

Instructions for use Compressed air injector with water trap

CVS10 Sanitary Check Valves

AKIT1901LM (Metal levers) AKIT1901XM (Cross Handles)

Type 4708 Supply Pressure Regulator

Technical Bulletin 148. Comparison of Flat Panel to MiniPanel. by:

THE MF-400 SERIES. Operating and Service Manual. Series includes all variants of MF-400/401

Mounting and Operating Instructions EB 8546 EN. Supply Pressure Regulator Type Fig. 1 Supply pressure regulators

Tubes Components Valves Units Engineering SO EVERYTHING KEEPS FLOWING. Safety valves Bunging valves Vacuum valves Tank dome fittings

STAD. Balancing valves DN 15-50

Pressure Relief Valve DHV 718

Differential pressure and flow controller (PN 16) AVPQ - return mounting, adjustable setting

Pressure relief valve DHV 718

TBV-CM. Combined control & balancing valves for small terminal units For modulating control NPT threads

HOVAP SERIES 9600 BASICFLOW PROCESS VALVES INSTRUCTION MANUAL

STAD-D. Balancing valves Balancing valve for domestic water systems, DN Balancing valves

Type 4708 Supply Pressure Regulator

Remeha Quinta Cascade guide

Model Series 62 Constant Differential Relay

Series 42 Self-operated Regulators Differential Pressure Regulators with Type 2424/Type 2428 Actuator (closing) Type Type 42-28

LRS(H)4 USER MANUAL. Read the complete manual before installing and using the regulator.

Biodec Decanter. Ideal with our CYCLATOR technology

STAD. Balancing valves DN (MD60, MD61, MD62)

CAST IRON SAFETY VALVE TYPE 6301

Liquid level glasses, type LLG REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Red Valve Coarse and Fine Bubble Air Diffuser Systems

VSR modulating valves with membrane actuator

TA-Modulator. Combined control & balancing valves for small terminal units Pressure independent balancing and control valve for modulating control

Fine Pore Aeration Systems Testing Michael K. Stenstrom Professor, Civil and Environmental Engineering Department

Unit 1, Fullerton Road Rotherham S60 1DJ. Tele: Fax:

Körting Liquid Jet Vacuum Ejectors

STA. Double regulating valves DN 15-50

Installation and Maintenance Instruction Manual

Old documentation - Only for your information! Product is not available anymore!

S1, S2, S3, S5, S6, S7, S8, S12 and S13 Separators Installation and Maintenance Instructions

Steam Trap BK BK 212-ASME. Original Installation Instructions English

GLAUNACH THE SILENCER HANDBOOK INSTALLATION GLAUNACH GMBH ALL RIGHTS RESERVED -

The activated sludge process

Combined Pressure / Vacuum Relief Valve KITO VD/o

Tank Blanketing Pressure Regulators RHPS Series

Contents. 1. General information BROEN BALLOMAX Steel Ball Valves Approvals Quality Management...2

Ball Float Steam Trap UNA 43 PN 16/CL 125/JIS 10K UNA 46 PN 40/CL 150/CL 300/JIS 10K/JIS 20K DN 80, 100, 150, 3", 4", 6"

Transcription:

BELÜFTUNGSTECHNIK UMWELT- & VERFAHRENSTECHNIK SERVICE & WARTUNG G E N E R A L I N F O R M A T I O N OXYFLEX - MF 650 MEMBRAN-PLATE-DIFFUSER for fine bubble aeration of liquids Supratec GESELLSCHAFT FÜR UMWELT- UND VERFAHRENSTECHNIK MBH von-drais-straße 7 D-55469 Simmern/Hunsrück Fon: *49 (0 67 61) 9 60 60 Fax: *49 (0 67 61) 9 70 774 e-mail: info@supratec.cc internet: www.supratec.cc

G E N E R A L Supratec I N F O R M A T I O N GENERAL INFORMATION Supratec Gesellschaft für Umwelt- und produces modern high efficient aeration systems, which are mainly used for oxygen transfer into biological waste water treatment. These products can also be used for any kind of transfer of gases into liquids. OXYFLEX is the brand of membrane diffusers (plate, tubes and discs) with a plastic body. The extra ordinary charachteristics of OXYLFEX -MF membrane plate diffusers are given by its shape and the materials used. DESIGN MEMBRANE OXYFLEX -MF membrane plate diffusers are available in two sizes: OXYFLEX -MF 650 (width length) 650 mm 150 mm and OXYFLEX -MF 1100 (width length) 1100 mm 200 mm. The body is a oval plate, made of glass reinforced made of Polypropylene. The membrane is fixed to this body with a plastic frame also made of glass reinforced Polypropylene. Standard membranes are made of SUPRAFORM (EPDM). Membranes made of SUPRASIL (Silicone) and SUPRADUR (Polyurethane) are also available. The membranes have a unique slot-arrangment. The size and arrangement of those slots is optimized to archieve maximum oxygen transfer efficiency. CHARACTERISTICS OXYFLEX -MF membrane plate diffusers have low pressure loss. OXYFLEX -MF membrane plate diffusers are highly resitant against soiling. OXYFLEX -MF membrane plate diffusers produce fine bubbles of a medium diameter < 2 mm. Unlike tube diffusers, the whole active diffuser surface is at the same hydraulic level, therefore the membranes operate evenly across the full range from minimal to maximal air flow. The feature results in optimum lifetime and efficiency. OXYFLEX -MF membrane plate diffusers can be operated intermittently. OXYFLEX -MF membrane plate diffusers can be installed with plastic- and/or stainless steel pipes and are used for all geometric forms of tanks, but they are extraordinarily good for medium and huge sized tanks. PERFORMANCE OXYFLEX -MF membrane plate diffusers are well established and are working to the clients satisfaction world-wide. OXYFLEX -MF membrane plate diffusers have a very wide range, OXYFLEX -MF 650: 0-1Nm /h. The design air flow should be approximately, OXYFLEX -MF 650: 7 ± 2 Nm /h OXYFLEX -MF membrane plate diffusers can reach specific oxygen transfer efficiency up to 25 go /Nm xm, if coverage and water depth is favourable. 2 sup COMBINATION VARIATIONS For plants with partly intermittent operated tanks, OXYFLEX -MF membrane plate diffusers can be combined with BRANDOL ceramic tube diffusers. However, different pressure losses have to be considered. Modifed OXYFLEX -MF membrane plate diffusers are also available for drinking water purposes. OXYFLEX -MF membrane plate diffusers are also available as coarse bubble diffusers. Supratec von-drais-straße 7 D-55469 Simmern Fon: +49 (0 67 61) 9 60 60 Fax: +49 (0 67 61) 970 774 info@supratec.cc

D R A W I N G O X Y F L E X - M F 6 5 0 A S Membrane Plate Diffuser OXYFLEX -MF 650 Type AS will be mounted onto distributor with a welded clamp (different diameter available). Materials: Body: Polypropylen (PP-GF) : Polypropylen (PP-GF) Clamp: Polypropylen (PP) Gasket: EPDM Membrane: SUPRASIL (Silikon) SUPRAFORM (EPDM) Membrane area: 0,1 m² Membrane Body Distributor Pipe Gasket Thread Connection Hole Ø 14mm Clamp 2 Pieces Hole Ø 14mm Distribution Pipe Distributor in different diameter e.g. Dn100, DN80 2 Pieces Clamp Membrane Supratec von-drais-straße 7 D-55469 Simmern Fon: +49 (0 67 61) 9 60 60 Fax: +49 (0 67 61) 970 774 info@supratec.cc

D R A W I N G O X Y F L E X - M F 6 5 0 B Membrane Plate Diffuser OXYFLEX -MF 650 Type B will be installed to a rectangular pipe by 4 welded thread bolts, those are welded to the pipe. Materials: Body: Polypropylen (PP-GF) : Polypropylen (PP-GF) Gasket: EPDM Membrane: SUPRASIL (Silikon) SUPRAFORM (EPDM) Membrane area: 0,1 m² Membrane Body plate Distributor Pipe Gasket Air-Socket Hole Ø 2mm 2 Pieces Threat bolts M6 Hole in Pipe Ø 2mm Distributor Pipe 2 Pieces Membrane Stand Juni 2009 Supratec von-drais-straße 7 D-55469 Simmern Fon: +49 (0 67 61) 9 60 60 Fax: +49 (0 67 61) 970 774 info@supratec.cc

C U R V E S P R E S S U R E - O X Y G E N OXYFLEX -MF650 membrane plate diffuser are high efficient diffusers and are mainly used for oxygen supply to biological waste water treatment plants. Beside procedural necessities, important criterions are used to select the matching fine-bubble aeration-technology to the features of a treatment plant. Systems using OXYFLEX -MF650 membrane plate diffusers are typically designed at a specific air-flow of 7 Nm /h per unit. This gives a good compromise between capital in investment and efficiency. The following table shows figures taken from an actual oxygen efficiency test. The values have been reached in a circular basin with water depth of 4,5m, submergence of diffusers of 4,15m and coverage of 11,27%. These are typical values particular to the test basin. The figures can deviation ± 25% in tanks of different sizes and diffuser density and loading. SUPRATEC GmbH would be pleased to produce a data-sheet for any individual application on request. No guarantee-claims can be derived from the diagram! 0 specific O 2-entrainment standard conditions and pressure loss OXYFLEX -Mf650 50 p OC OCL,h [go2/(nm³ x met)] 25 20 40 0 p [mbar] 15 20 10 0 1 2 4 5 6 7 8 9 specific load [Nm³/m] 10 Supratec von-drais-straße 7 D-55469 Simmern Fon: +49 (0 67 61) 9 60 60 Fax: +49 (0 67 61) 970 774 info@supratec.cc

I N S T A L L A T I O N Supratec M A N U A L DESCRIPTION OXYFLEX -MF650 - membrane plate diffuser Type AS has a solid, strong, horizontal body, made of glass-reinforced Polypropylene and a slipped over membrane (e.g. EPDM). The two-piece-frame, made of glass-reinforced Polypropylene ensures the proper location of the membrane. The body has a connecting-thread (standard 1 BSPmale) that is welded into a Polypropylene clamp. This clamp can be fastened by screws or wedges. The integral gasket of the clamp seals the system. MEASUREMENTS Width: 189 mm, Length: 680 mm, Height: 21 mm - with rounded edges (not including clamp) 2 Free membrane area: Length: 650 mm, Width: 150 mm (0,1 m ) STORAGE PREPARATION The diffusers should be stored in their packing inside a dry and aerated building. DIN 7716 has to be considered. Before installation of the OXYFLEX -MF 650 - membrane plate diffuser Type AS it has to be checked that the piping system is clean. Drilling chips, dirt etc. have to be removed, as those will be transported into the diffusers as soon as blowers are set into operation causing serious damage to the diffuser membranes. LEVELLING INSTALLATION OXYFLEX -MF 650 - membrane plate diffuser Type AS normally installed onto round pipes. The piping system has to be levelled to maximum ± 10 mm. OXYFLEX -MF 650 - membrane plate diffuser Type AS can be fixed to round pipes made of stainless steel or plastic, with a minimum diameter of 50 mm. On the upper side of those pipes, centred holes of diameter Ø 14 mm must be made. The clamp will be installed in such a way, that the hole of Ø 14 mm and the opening of the clamp are aligned. Care must be taken of the horizontal seat of the diffusers. The O-Ring seal, made of EPDM must be clean and undamaged and should sit between diffuser and pipe. Supratec von-drais-straße 7 D-55469 Simmern Fon: +49 (0 67 61) 9 60 60 Fax: +49 (0 67 61) 970 774 info@supratec.cc

O P E R A T I O N M A N U A L FUNCTION AND LEAKAGE CHECK FIRST RUN OF DIFFUSERS VISUAL BUBBLE CHECK OXYGEN- TRANSFER- EFFICIENCY TEST START UP After installation of OXYFLEX -MF 650 membrane plate diffusers a function and leakage test should be carried out. The tank should be filled with clean water up to maximum 10 cm above diffusers surface and the diffusers set in operation (specific air flow: 6 Nm /h per unit). Then function and installation can be checked and confirmed by report. After function and installation has been checked and confirmed OXYFLEX -MF 650 membrane plate diffusers have to be operated at least another 60 hours continuously, at a specific air flow of minimum 10 Nm /h per unit. Water level shall be as quickly as possible raised up to minimum 100 cm above diffusers surface. IMPORTANT: Diffusers should not stand still Specific air flow should not exceed 1 Nm /h per unit. The visual judgement of the bubble distribution should not be taken before the above specific first run of diffusers. To do the visual check, the diffusers shall operate at maximum capacity and shall be turned to the minimum. Test of even aeration (visual bubble check) must take place when the water level is at least 60-100 cm above diffusers surface and a specific air flow of at least 6 Nm /h per unit. Test of even aeration (visual bubble check) at minimum air flow can only take place if the water temperature is above 10 C. Before the stated oxygen transfer efficiency figures of the OXYFELX - MF 650 membrane plate diffusers are proved with an oxygen transfer efficiency test, the above mentioned steps have to be considered. The oxygen transfer efficiency test must be done accordingly to accepted rules (e.g. ATV-M 209) in clean or waste water. Guarantee figures have to be controlled exactly. It is necessary to have a precise air-flow measurement system. After successful oxygen transfer efficiency test, start up of the OXYFLEX -MF 650 membrane plate diffusers may follow immediately. If there is a postponement of the start up, care should be taken that the water level stays at least 100 cm above diffusers surface to protect OXYFLEX -MF 650 membrane plate diffusers from sunlight and / or freezing. Supratec von-drais-straße 7 D-55469 Simmern Fon: +49 (0 67 61) 9 60 60 Fax: +49 (0 67 61) 970 774 info@supratec.cc

M A I N T E N A N C E M A N U A L MAINTENANCE OXYFLEX -MF 650 membrane plate diffusers do not need a lot of maintenance. Usually it is enough to have one run of 10 to 15 minutes operation at minimum air-flow per day, where each single OXYFLEX -MF 650 membrane plate diffuser shall operate at a specific air-flow of at least 10 Nm /h per unit. To do so, it may help to shut down the system partially, by closing the corresponding valves. This removes layers of sludge which may have occurred after long times of in operation of the system or long times of low specific air flow. At least once per year OXYFLEX - MF 650 membrane plate diffusers should be checked visually, particulary they should be checked for layers of sludge or similar. If so, those layers should be removed carefully. A seperate maintenance-contract is available. SUPERVISION A Visual bubble check should be carried out daily. The pressure loss of the system should be monitored and reported monthly. Apparent changes of the bubble distribution and/or of the pressure loss should be promptly reported to SUPRATEC GmbH, especially at installations with intermittent operation where there is a risk that activated sludge could penetrate the entire piping through a damaged OXYFLEX -MF 650 membrane plate diffuser which would affect function and lifetime of all OXYFLEX -MF 650 membrane plate diffusers in the system. The maximum of SUPRATEC GmbH s warranty for OXYFLEX -MF 650 membrane is 24 months. Longer warranty can be arranged only with conclusion of a maintenance contract between the operator and SUPRATEC GmbH. Damage and/or other influences are specifically excluded from the warranty promise. WARRANTY The warranty ends if it is known, that sewage is partially or mainly of industrial origin and/or the sewage has a damaging influence on membrane diffusers and SUPRATEC GmbH was not informed accordingly. In such a case, a confirmation of the warranty is to be ordered through SUPRATEC GmbH. The general sales and warranty conditions of SUPRATEC GmbH apply. Supratec von-drais-straße 7 D-55469 Simmern Fon: +49 (0 67 61) 9 60 60 Fax: +49 (0 67 61) 970 774 info@supratec.cc