Supratec. von-drais-straße 7 D Simmern/Hunsrück Fon: +49 ( 67 61) Fax: +49 ( 67 61)

Similar documents
Supratec. MEMBRANE-PLATE-DIFFUSER For fine bubble aeration of liquids BELÜFTUNGSTECHNIK UMWELT- & VERFAHRENSTECHNIK SERVICE & WARTUNG

Supratec von-drais-straße 7 D Simmern/Hunsrück Fon: *49 ( ) Fax: *49 ( )

Supratec Gesellschaft für Umweltund Verfahrenstechnik mbh OXYFLEX - M T / M T M E M B R A N E D I S C D I F F U S ER AERATION TECHNOLOGY

Supratec AERATION TECHNOLOGY. von-drais-straße 7 D Simmern / Hunsrück. tel.: / fax: /

aeration and mixing systems

Disc diffuser ELASTOX -T

Pressure Reducing Valve DMV 750

FINE BUBBLE DISC DIFFUSER

Panel diffuser ELASTOX -P

RAUBIOXON PLUS Pipe Aerator

Pressure relief valve DHV 712 DN 65-80: 0,5-10 bar, DN : 0,3-4 bar, DN 100: 0,5-6 bar

Pressure Reducing Valve

Pressure Reducing Valve DMV 750 set range: bar

Instructions for Use. Plug connection for medical gas and vacuum acc. to DIN / 2004 DIN EN ISO

Installation and commissioning instructions 255 series and 256 series

Pressure relief valve DHV 716 set range: 0,5-10,0 bar

Instruction presentation Special valves

Armatures for analytical probes

Pressure Reducing Valve DMV 755

Pressure Relief Valve DHV 718

Johnston Invar Coupling Johnston Invar Coupling

AVK SERIES 601, 602, 603 & 605 UNIVERSAL COUPLINGS, ADAPTORS & END CAPS INSTALLATION, OPERATION & MAINTENANCE MANUAL

Pressure Reducing Valve DMV 755 set range: 1,0-9,0 bar

vacon nx ac drives hxm120 cooling unit, ss-piping commissioning and maintenance manual

vacon nx ac drives hxl040 cooling unit, ss-piping commissioning and maintenance manual

Pressure relief valve DHV 718

FORMIC ACID DOSING STATION

OXYGEN and SYSTEM OXY

Operating instructions - Translation of the original -

Mounting and Operating Instructions EB EN. Type Supply Pressure Regulator. with increased air capacity

OPTIPOW 105 OPTIPOW 105 ; MAIN PARTS. Our Ref: PSE, Bernt Andersson

RAUBIOXON AND RAUBIOFLEX AERATOR SYSTEMS TECHNICAL INFORMATION

Installation Instructions MODEL VSTI-A020 Tank Indicator Installation Model: VSTI-A020, Stainless Reverse Read System Versa Steel Inc. Guide Cables No

STAD. Balancing valves DN (MD60, MD61, MD62)

Type 4708 Supply Pressure Regulator

Tank Blanketing Pressure Regulators RHPS Series

Filtration FILTRATION PRODUCT TIPS

INSTALLATION, OPERATION AND MAINTENANCE GUIDE

Installation, Operation & Maintenance Manual

// ADapters GUIDelines

TA-COMPACT-P. Combined control & balancing valves for small terminal units Pressure independent balancing and control valve (PIBCV)

Pressure Relief Valve DHV 718

Differential pressure and flow controller (PN 16) AVPQ - return mounting, adjustable setting

STAD. Balancing valves DN 15-50

Installation, operation & maintenance manual - original version

Modular valve block. Operating manual Series MVB 100/200. Version BA EN Print-No TR MA DE Rev001

Pressure relief valve DHV 725 set range: 0,2-10,0 bar

PARTS & SERVICE. regulator (new) for NGW/ GBW applications. Rev. 02/2018 Id.No. DOK50026

General page Straight unions page Angle unions page Tee and L-unions page Gauge connection unions page 42

Operating instructions - Translation of the original -

BUTTERFLY VALVES. Toll Free (877) - ICFLUID -2-

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25

World Area Differences Technical Information

ELADOS EDP L Diaphragm Metering Pump Type

Cost effective. Smooth. Reliable. LOG Internal Hole Gripper

BTV. Internally threaded 2-way control valve. Flow characteristics. Function

Operating instructions - Translation of the original -

TA-Modulator. Combined control & balancing valves for small terminal units Pressure independent balancing and control valve for modulating control

Pneumatic proportional controller Types M Types FM Function tested for use of the float in Ex-zone 0

Pneumatic retractable fitting for simple commercially available control units or process applications

Coiling Tube with Twist-Proof Fitting

INSTRUCTION MANUAL Pressure Relief Device LPT

Installation and Operating Instructions Bypass Flow Meter DST

Type 4708 Supply Pressure Regulator

STA. Double regulating valves DN 15-50

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

Steam Trap BK BK 212-ASME. Original Installation Instructions English

Self-operated Pressure Regulators for special applications

STAD-C. Balancing valves DN 15-50

MUELLER. A Wall Type. Indicator Post. Reliable Connections. General Information 2. Technical Data/ Dimensions 3. Installation 4-5.

Mounting and Operating Instructions EB 8546 EN. Type 4708 Supply Pressure Regulators. Translation of original instructions. Type Type

Instrument Operating Manual

Gas Pressure Regulator HON 300

OPERATING MANUAL CHEMTRAC 840M MANUAL RETRACTABLE PROCESS HOLDER

INSTALLATION INSTRUCTIONS FOR GRT75-PF-RFS PET FOUNTAIN

OPERATING INSTRUCTIONS

Pneumatic switch module 3/2-way valve (On/Off) Types P Types FP Function tested for use of the float in Ex-zone 0

MUELLER. A A Adjustable. Vertical Indicator Posts. Reliable Connections. General Information 2. Technical Data 3.

THE MF-400 SERIES. Operating and Service Manual. Series includes all variants of MF-400/401

Unit 1, Fullerton Road Rotherham S60 1DJ. Tele: Fax:

STAD-D. Balancing valves Balancing valve for domestic water systems, DN Balancing valves

Instructions for use Compressed air injector with water trap

Size : Ends : Min Temperature : Max Temperature : Materials : Cast iron EN GJL 250 body. Reinforced lug for DN200 :

W A S T E W A T E R T R E A T M E N T S Y S T E M S

Cable entries. Contents. Cable entries. Cable entries Introduction L.2 L.1. Standard cable glands - Plastic L.5. Standard cable glands - Brass L.

Self-operated Regulators Accessories Differential Pressure and Flow Regulators

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS FOR SSI WIDEBAND DIFFUSER

Technical Bulletin 148. Comparison of Flat Panel to MiniPanel. by:

better measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars.

Steam Trap BK 15 (DN40, DN 50) Original Installation Instructions English

Operating instruction for the quick-change tap holders type:

Supplementary instructions. Rod and cable components. for VEGAFLEX series 80. Document ID: 44968

THE BP-690 SERIES. Operating and Service Manual. Series includes all variants of BP-LF/MF-690/691

TBV-CM. Combined control & balancing valves for small terminal units For modulating control

SEries 29 Hydrant valves installation, operation & maintenance manual

VALFONTA INSTRUCTIONS: OPERATION AND INSTALLATION PRESSURE REDUCING VALVE MODEL PRV44

Mounting and Operating Instructions EB 2172 EN. Series 43 Temperature Regulators. Type 43-5 and Type Type Type 43-6

Pressure relief valve

UltRo Dual Flow Reverse Osmosis Water System

Transcription:

O X Y FLEX - OM O VA L-MEMBRANE-TUBE-DIFFUSER for fine bubble aeration of liquids UND GESELLSCHAFT FÜR UMWELT- VERFAHRENSTECHNIK mbh von-drais-straße 7 D-55469 Simmern/Hunsrück Fon: +49 ( 67 61) 9 65 09-00 Fax: +49 ( 67 61) 9 65 09-01 e-mail: info@oxyflex.de internet:www.oxyflex.de

G E N E R A L D E T A I L S G E N E R A L I N F O R M A T I O N Gesellschaft für Umwelt- und produces modern high efficient aeration systems, as they are usually used for oxygen supply of biological waste water treatment. These products could also be used for any kind of gasation of liquids. OXYFLEX is the brand of membrane diffusers (plate, disc and tube) and a Polypropylene (PP) body. D E S I G N M E M B R A N E The Oval Tube Diffuser - OXYFLEX OM are offered in three sizes: OXYFLEX OM 1,0 (diameter x length) 120/ mm x 540 mm OXYFLEX OM 1,5 (diameter x length) 120/ mm x 790 mm OXYFLEX OM 2,0 (diameter x length) 120/ mm x 1040 mm The length of the diffuser can be fitted and produced especially to your requirements. The body is a Polypropylene (PP) reinforced oval tube. A membrane is putted over this body. A non return valve is integrated in the body. Concerning the with of the oval body of the diffuser, and the resulting wide working area there is a high efficiency given. A additional advance of the oval membrane tube diffusers - OXYFLEX OM is the very little pressure loss corresponding to the high efficiency. Standard membranes are made of EPDM. s made of Silicone are also available. The membranes have a unique slot-arrangement. The size and arrangement of those slots is optimized to archive maximum oxygen transfer efficiency. C H A R A C T E R I S T I C S Oval membrane tube diffusers - OXYFLEX OM are highly resistant against soiling. Oval membrane tube diffusers - OXYFLEX OM produces fine bubbles of a medium diameter < 2mm. Oval membrane tube diffusers - OXYFLEX OM can be operated intermittently. Oval membrane tube diffusers - OXYFLEX OM can be installed with Polypropylene pipes and stainless steel pipes, are used for all geometric forms of tanks and fit to nearly every type of pipe. Oval membrane tube diffusers - OXYFLEX OM satisfaction world-wide. are well established and are working to the clients' P E R F O R M A N C E Oval membrane tube diffusers - OXYFLEX OM have a wide range. Minimum to maximum specific air-flow reaches from 0-20 Nm³/h per meter. The design air flow should be approximately 8 ± 2 Nm³/mh. Oval membrane tube diffusers - OXYFLEX OM can reach specific oxygen transfer efficiency up to 28 go2/nm³ x met, if coverage and water depth is favourable. V A R I A T I O N S Oval membrane tube diffusers - OXYFLEX OM are also available as coarse bubble diffusers.

O P E R A T I O N M A N U A L F U N C T I O N - A N D L E A K A G E C H E C K After installation of oval membrane tube diffusers - OXYFLEX OM a function and leakage test should be carried out. The tank should be filled with clean water up to maximum 10 cm above diffusers' surface and the diffusers set in operation. Then function and installation can be checked and confirmed by report. F I R S T R U N O F D I F F U S E R After function and installation has been checked and confirmed, oval membrane tube diffusers - OXYFLEX OM have to be operated at least another 60 hours continuously. Water level shall be as quickly as possible raised up to minimum 100 cm above diffusers' surface. Important: Diffusers should not stand still. V I S U A L B U B B L E C H E C K The visual judgement of the bubble distribution should not be taken before the above specified first run of diffusers. To do the visual check, the diffusers shall operate at maximum capacity and shall be turned down to the minimum. Test of even aeration (visual bubble check) must take place when the water level is at 60-100 cm above diffusers' surface. Test of even aeration (visual bubble check) at minimum air flow can only take place if the water temperature is above 10 C. OXYGEN- TRANSFER- E F F I C I E N C Y - T E S T Before the stated oxygen transfer efficiency figures of the oval membrane tube diffusers - OXYFLEX OM are proved with an oxygen transfer test the above mentioned steps have to be considered. The oxygen transfer efficiency test must be done accordingly to accepted rules (e.g.: ATV-M209) in clean or waste water. Guarantee figures have to be controlled exactly. It is necessary to have a precise air-flow measurement system. S T A R T - U P After successful oxygen transfer efficiency test, start up of the oval membrane tube diffusers - OXYFLEX OM may follow immediately. If there is a Postponement of the start up, care should be taken that the water level stays at least 100 cm above diffusers' surface to protect oval membrane tube diffusers - OXYFLEX OM from sunlight and / or freezing.

D R A W I N G Oval--Tube-Diffuser OXYFLEX OM Oval - Tube-Diffuser OXYFLEX OM can be mounted on stainless steel rectangular pipe and PP-pipes (connectors for different diameters/size are available). Werkstoffe / Materialien: Body: Polypropylen (PP-GF) Gasket: EPDM : EPDM Inner diameter of the : 90mm Mounting with connector 180 530 / 780 / 1030 Connector 120 90 Air socket rectangular pipe Mounting with U-clamp 95 530 / 780 / 1030 1 Screw connection M6 112 rectangular pipe 120 1 90 Rectangular pipe 80 x 80 Air socket U-Clamp (around rectangular pipe)

D R A W I N G Mounting with stay bolts 530 / 780 / 1030 Stay bolt M6 Rectangular pipe 90 112 90 Adapter rectangular mounting with bolts Air socket Stay bolt M6 Mounting with connector Screw connection M8 x Connector for Ø 75, 90, 110 PP-pipe Ø 75, 90, 110 70 Connector Air socket

C U R V E S P R E S S U R E - O X Y G E N Values in the example shown below are determinted in water-depth of 4m / 3,8 met and with planar arrangement of the diffusers. The values are not transferable >> No guarantee-claims can be derived from the diagram! << Specific oxygen transfer efficiency and pressure loss of the OXYFLEX - OM Oval- Tube-Diffuser Specific oxygen transfer efficiency [g O 2 / (Nm³ x m ET )] Spedific oxygen transfer efficiency Pressure loss Pressure loss per diffuser [mbar] Specific load of OXYFLEX OM Oval--Tube-Diffuser [ Nm³/h per diffuser ]

I N S T A L L A T I O N M A N U A L D E S C R I T I O N Oval membrane tube diffuser - OXYFLEX OM has a solid, strong body made of Polypropylene (PP) and a slipped over membrane (e.g.: EPDM). The membrane is fixed by two SS ring-clamps. The body is to be out around the ends shaped, and has an integrated non return valve. S T O R A G E The diffusers should be stored in their packing inside a dry and aerated building. DIN 7716 has to be considered. P R E P E R A T I O N Before installation of the oval membrane tube diffusers - OXYFLEX OM it has to be checked that the piping system is clean. Drilling chips, dirt etc. have to be removed, as those will be transported into the diffusers as soon as blowers are set into operation causing serious damage to the diffuser membranes. L E V E L L I N G Oval membrane tube diffusers - OXYFLEX OM are installed on various pipes. The piping system has to be levelled to maximum ± 10 mm. I N S T A L L A T I O N Installation on rectangular pipe: Rectangular adapter: The pair of diffusers with the adapter will be putted on the rectangular pipe from ahead. They will bolt together with welded bolts directly on the rectangular pipe or with U-Bolts who surrounds the rectangular pipe. All is shown in the drawings attached. Connector: The connector will be screwed in the body of the diffuser with the short thread first. Now mounting the second body an screw it into the other side of the connector. With the jaw spanner SW 77 mm you tighten up the bodies with a torque of 45Nm.All is shown in the drawings attached. Connector clamp: The half parings of the rectangular pipe connector clamp will be hooked up each other and closed around the rectangular pipe. On the opposite the clamp will be fixed with a screw. All is shown in the drawings attached. Installation on round pipe: Half parings: The half parings of the diffusers encompass the round pipe and will be fixed with a screw M8x, washers and nuts on the opposite half paring.all is shown in the drawings attached. All fittings have to be tighten stepwise, to exclude canting!

M A I N T E N A N C E M A N U A L M A I N T E N A N C E Oval membrane tube diffuser OXYFLEX OM does not need a lot of maintenance. Usually it is enough to have one run of 10 to 15 minutes operation at maximum air flow per day, where the Oval membrane tube diffuser OXYFLEX OM shall operate at least 10 Nm³/h and m per unit. To do so, it may help to shut down the system partially, by closing the corresponding valves. This also removes layers of sludge after longer time not having operated the system or longer terms of low specific air flow. At least once per year Oval membrane tube diffuser OXYFLEX OM shall be checked visually. Here especially shall be checked whether there are layers of sludge or similar. If so, those layers shall be removed carefully. A separate maintenance contract can be completed. S U P E R V I S I O N A visual bubble check has to be done daily. The pressure loss of the system has to be controlled and reported monthly. Showy changes the bubbles distribution and/or of the pressure loss are prompt to be report at SUPRATEC. Especially the installations with intermittent operation exists the risk, that activated sludge penetrates the entire piping, by damaged Oval membrane tube diffuser OXYFLEX OM. Hereby, all oval membrane tube diffuser OXYFLEX OM are affected in function and lifetime.