Supratec AERATION TECHNOLOGY. von-drais-straße 7 D Simmern / Hunsrück. tel.: / fax: /

Similar documents
Supratec Gesellschaft für Umweltund Verfahrenstechnik mbh OXYFLEX - M T / M T M E M B R A N E D I S C D I F F U S ER AERATION TECHNOLOGY

Supratec. von-drais-straße 7 D Simmern/Hunsrück Fon: +49 ( 67 61) Fax: +49 ( 67 61)

Supratec von-drais-straße 7 D Simmern/Hunsrück Fon: *49 ( ) Fax: *49 ( )

Supratec. MEMBRANE-PLATE-DIFFUSER For fine bubble aeration of liquids BELÜFTUNGSTECHNIK UMWELT- & VERFAHRENSTECHNIK SERVICE & WARTUNG

Disc diffuser ELASTOX -T

aeration and mixing systems

Panel diffuser ELASTOX -P

FORMIC ACID DOSING STATION

Mounting and Operating Instructions EB 2558 EN. Self-operated Pressure Regulators. Type Pressure Build-up Regulator

RAUBIOXON PLUS Pipe Aerator

Installation and commissioning instructions 255 series and 256 series

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25

Self-operated Pressure Regulators for special applications

Pressure Reducing Valve DMV 750 set range: bar

Pressure relief valve DHV 712 DN 65-80: 0,5-10 bar, DN : 0,3-4 bar, DN 100: 0,5-6 bar

Installation, operation & maintenance manual - original version

Pressure Reducing Valve DMV 755 set range: 1,0-9,0 bar

OXYGEN and SYSTEM OXY

Pressure relief valve DHV 716 set range: 0,5-10,0 bar

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly.

Siphon vessel / Priming aid

Overflow valves Type OFV REFRIGERATION AND AIR CONDITIONING. Technical leaflet

OPERATING MANUAL CHEMTRAC 840M MANUAL RETRACTABLE PROCESS HOLDER

Type BBS-03, BBS-05, BBS-06, BBS-25

UsER manual for Watersens ph -REDOX

COMPRESSION TUBE FITTINGS

Mounting and Operating Instructions EB 3017 EN. Self-operated Regulators

AVK SERIES 601, 602, 603 & 605 UNIVERSAL COUPLINGS, ADAPTORS & END CAPS INSTALLATION, OPERATION & MAINTENANCE MANUAL

Pressure relief valve DHV 725 set range: 0,2-10,0 bar

Overflow valves Type OFV Type OFV-SS REFRIGERATION AND AIR CONDITIONING. Technical leaflet

RAUBIOXON AND RAUBIOFLEX AERATOR SYSTEMS TECHNICAL INFORMATION

FINE BUBBLE DISC DIFFUSER

Instruction Manual SB02, SB03, SB04 All metal flow limiter

Armatures for analytical probes

INSTRUCTION MANUAL Pressure Relief Device LPT

Operating instruction for the quick-change tap holders type:

Oxymax W COS41. Technical Information. Potentiostatic amperometric two-electrode sensor Long-term stable sensor for water and wastewater applications

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

Type 4708 Supply Pressure Regulator

Installation and Operating Instructions Bypass Flow Meter DST

Mounting and Operating Instructions EB 2172 EN. Series 43 Temperature Regulators. Type 43-5 and Type Type Type 43-6

Series 42 Self-operated Regulators Differential Pressure Regulators with Type 2424/Type 2428 Actuator (closing) Type Type 42-28

Pressure Relief Valve DHV 718

Ball Float Steam Trap UNA 45 MAX, UNA 46 MAX, UNA 46A MAX PN 40/Class 300 DN 40, 50, 65

PRS(TC)4,8 USER MANUAL. Read the complete manual before installing and using the regulator.

Pressure Reducing Valve DMV 755

Regulating valves REG-SA and REG-SB

HERZ-Motorised flow controler

Regulating valves Type REG 6-65 Type REG-SS REFRIGERATION AND AIR CONDITIONING. Technical leaflet

FITTINGS AND VALVES Düker Plunger Valve RKV Type 7015 Professional control of flow rates, reservoir levels and pressures Safe, hygienic and durable!

Pressure Reducing Valve DMV 750

Tank Blanketing Pressure Regulators RHPS Series

Mounting and Operating Instructions EB 3009 EN. Self-operated Regulators. Type RS Check Valve (backflow protection)

HUBER Rotary Drum Fine Screen ROTAMAT Ro2 / RPPS / STAR

Rapidmain Installation Guide

Repair instructions. Pivot bushing replacement. XL-AS10001RM-en-DE Rev B

Technical Data Sheet TI-F50 Locking Units series KFH

Pressure regulating valves Types OFV, OFV-SS

Two-stage valve type NE

Expert Hydrostatic Level Transmitters

Steam Trap BK BK 212-ASME. Original Installation Instructions English

ALU-CD 12, ALU-CD 25, ALU-CD 35, ALU-CD

Expansion Thermometers Stainless Steel Series, Model 70

PUNE TECHTROL PVT LTD. Instruction and Maintenance Manual for Float and Tape Gauge FTG

Mounting and Operating Instructions EB EN. Type Supply Pressure Regulator. with increased air capacity

Radiator valves VDN1.. VEN1..

COMPRESSION TUBE FITTINGS

UIB30 and UIB30H Sealed Inverted Bucket Steam Traps for use with Pipeline Connectors

ROTAMAT Rotary Drum Fine Screen Ro 2 / RPPS

Gas powered stop valves, type GPLX REFRIGERATION AND AIR CONDITIONING. Technical leaflet

DICTATOR "DIREKT" Gate Closer

OXY Integral. INTERCON ENTERPRISES INC Tel: Fax: Internet:

Fine Bubble Tube Aeration System O&M Manual INSTALLATION INSTRUCTIONS FOR THE SSI TUBE DIFFUSER

Torque Specifications

AIR COMPRESSOR MANUAL INSTALLATION, OPERATION AND MAINTENANCE GUIDE

BUTTERFLY VALVES Series 800

INSTALLATION INSTRUCTIONS FOR GRT75-PF-RFS PET FOUNTAIN

For optimal strength and durability, we use a co-extrusion process of 3 different PVCs in the manufacturing of our pool cover slats.

Pneumatic proportional controller Types M Types FM Function tested for use of the float in Ex-zone 0

Flowmeter. Original operating manual DFM

30T A/Manual Hydraulic Shop Press

KBV21i and KBV40i Key Operated Boiler Blowdown Valves Installation and Maintenance Instructions

Technical Information Cleanfit CUA451

INSTALLATION INSTRUCTIONS FOR SSI WIDEBAND DIFFUSER

Laboratory Mortar Mixer (Testing)

Instructions for Use. Plug connection for medical gas and vacuum acc. to DIN / 2004 DIN EN ISO

400V 50Hz. Tsurumi TRN. Submersible aerator. Auto-suction submersible aerator for communal and industrial waste water clearance and treatment.

Translation of the original Operating Instructions for HKS rubber compensators

WARNING! Equipment for treatment of water intended for human consumption (Directive 98/83 CE).

Operating Instructions Flowfit CUA252

KBV21i and KBV40i Air Actuated Boiler Blowdown Valves

Declaration of Conformity as per Directive 97/23/EC

The activated sludge process

Instruction Manual. Standard Surge Eliminator. Standard X. Flushable X - X

Pressure Reducing Valve

Quality Plastic Pipe Fittings. Technical Data. Fabricated PVC Fittings IPS Class 100, 125, 160, 200 SCH 40 & SCH 80 Solvent Weld & Gasketed

UNA 45 UNA 46 UNA 46A

Engineering Data Sheet

OPERATING INSTRUCTIONS

Technical Data Sheet T 2025

Transcription:

PERMOX OM120 Oval Membrane Tu b e D i ffuser w i th stainless steel b o d y Supratec for fine bubble or coarse bubble diffusion of liquids Supratec UND GESELLSCHAFT FÜR UMWELT- VERFAHRENSTECHNIK MBH AERATION TECHNOLOGY von-drais-straße 7 D-55469 Simmern / Hunsrück tel.: +49 6761 / 9 65 09-00 fax: +49 6761 / 9 65 09-01 e-mail: info@oxyflex.de internet: www.oxyflex.de

PERMOX OM120 Oval membrane tube diffuser The PERMOX OM120 oval membrane tube diffuser is an improvement of old PERMOX OM with new width of 120 mm, instead of former width of only 90 mm. PERMOX OM120 oval membrane tube diffuser consists of a solid, strong body stainless steel body (AISI 316). The special oval form of the stainless steel tube results in strong high efficient tube diffuser. The diffuser membrane is secured to the body by two stainless steel 1-ear clips. The high-quality membranes are available in EPDM (ethylene propylene diene rubber). The PERMOX OM120 is available in two sizes: - PERMOX OM120-1. 5 with an active flat membrane surface of 0.18m² - PERMOX OM120-2.0 with an active flat membrane surface of 0.24m² The PERMOX OM120 oval membrane tube diffuser is a fine bubble aeration element for efficient aeration, which is mainly used for the oxygen supply of biological waste water treatment plants. In contrast to the traditional tube diffuser, the entire active surface of the oval tube diffuser is at a hydraulic level. Even for different specific air loads, the entire flat active membrane surface works always evenly. This special shape realizes only a very small pressure increase during service life and a significantly increased efficiency compared to other tube diffuser types. The PERMOX OM120 oval membrane tube diffuser is characterized by the following superior features: efficient oxygen transfer stable pressure loss special diffuser design, optimized for liftable grids (no buoyancy) easy cleaning of the membranes resulting in low-maintenance operation The membranes are perforated individually. The PERMOX OM120 oval membrane tube diffuser is able to cover a very broad operating range of up to 15 /h per meter. The PERMOX OM120 oval membrane tube diffuser can be operated in intermittent mode. As an alternative to fine-bubble aeration diffuser, the membrane can also be manufactured for a coarse-bubble version. The oval membrane tube diffuser type PERMOX OM has been used successfully in Germany and worldwide in communal and industrial waste water treatment plants for many years. It is also suitable for aerating liquids of all kinds were stainless steel bodies are suitable. We will be pleased to send you our current list of references on request.

With the fine-bubble design of PERMOX OM120 oval membrane tube diffuser, specific oxygen transfer rates in pure water of more than 25 g O 2/( x m ET) can be achieved with an extensive layout and correct water depth. The following diagram shows the example of a result of an oxygen transfer test. The values were measured in a rectangular tank with a water depth of 4.0 m, a diffuser blow-in depth of 3.8 m and coverage of 20%. specific standard oxygen transfer SSOTR and pressure loss of 1 PERMOX OM120 oval membrane tube diffuser 34 70 specific standard oxygen transfer SSOTR [go 2 / /m ET ] 32 30 28 26 24 22 20 18 16 14 12 specific standard oxygen transfer SSOTR pressure loss 60 50 40 30 20 pressure loss of diffuser [hpa] 10 10 0 2 4 6 8 10 12 14 16 specific airload of PERMOX OM120 oval membrane tube diffuser [ /h per m diffuser length] 1 The diagram cannot be used in order to derive warranty claims of any kind. The values cannot be transferred to other plants. The results that are shown here depend on several influencing factors, such as the tank shape, blow-in depth, coverage or a separate recirculation due to additional mixers. Supratec will be pleased to prepare a technical data sheet for each individual application for you on request. AIR-PULSING: mixing without a mixer The option of the intermittent operating mode means that in a combined tank with alternating nitrification and denitrification phases and for a sufficient coverage by PERMOX OM120 oval membrane tube diffusers, the use of a mixer will not be necessary ("Air-Pulsing" process). Any sedimentation of the activated sludge during the denitrification phase is prevented by short-term aeration intervals. The required aeration intervals are individually adapted to the respective plant with regard to its specific conditions such as the sludge index of the waste water. The aeration time is limited to some minutes and the process is repeated approximately every 10 to 20 minutes depending on the plant type.

Installation The PERMOX OM120 oval membrane tube diffuser is suitable for installation on rectangular stainless steel pipes by using U-bolts (M8). U-bolts are available for rectangular pipe dimension 100 mm x 100 mm or 80 mm x 80 mm as standard (other sizes on request). Membrane: EPDM Oval tube body: stainless steel (AISI316) Clamp saddle: stainless steel (AISI316) U-bolts: stainless steel (AISI316) Seals: EPDM flat active diffuser surface General information Supratec Gesellschaft für Umwelt- und has more than 30 years of experience with aeration technology and manufactures state-of-the-art aeration systems. These products are mainly used for providing the oxygen supply for biological waste water treatment processes but can also be used for the aeration of liquids of all kinds. Possible areas of application for Supratec diffusers are: Municipal waste water treatment plants Industrial waste water treatment plants Special technical processes such as the "stripping" of gases, etc. We have the competence and wealth of experience in order to consult and support you with the planning, implementation and operation of your projects. We will also carry out the installation of our products for you if required. For further notes and special information please see following installation, operating and maintenance instructions.

INSTALLATION INSTRUCTIONS Dimensions 120 mm Storage The diffusers shall be stored in their packing inside a dry and aerated building. DIN 7716 has to be considered. Preparation Before installation of the oval membrane tube diffusers PERMOX OM120, it has to be checked that the piping system is clean inside. Cuttings, sludge or other dirt have to be removed, as those will be transported into the diffusers as soon as blowers are set into operation and causing serious damage to the diffuser membranes. Levelling PERMOX OM120-1.5 1660 mm PERMOX OM120-2.0 2210 mm Oval membrane tube diffusers PERMOX OM120 can be installed on square pipes with dimensions 80 mm x 80 mm or 100 mm x 100 mm (different sizes on request). The piping system has to be levelled to maximum ± 10 mm. Installation on rectangular pipe Oval membrane tube diffusers PERMOX OM120 must be mounted horizontally and right-angled on rectangular stainless steel distribution pipes with bore holes Ø 30mm at the top. The distance between the oval membrane tube diffusers PERMOX OM120 on the distribution pipe (connection bore hole axis) should be at least 200 mm, recommended 25 mm 500 mm and must not exceed 1,000 mm (differences possible on request). A self-sticking round EPDM gasket (50/30 mm x 3 mm) is positioned around the bore hole of the distribution pipe. The surfaces of the rectangular pipe must be clean, dry and straight. The air socket outer-ø = 28 mm at the bottom side of oval membrane tube diffuser PERMOX OM120 is inserted from above into the bore hole Ø = 30 mm of the rectangular distribution pipe. clamp saddle self-locking nuts EPDM membrane bore hole Ø = 30 mm distribution pipe oval stainless steel body U-bolts M8

The gasket must sit clean and undamaged between the diffuser and the pipe. The fixing clamp saddle will be put from the top to the oval membrane tube diffuser PERMOX OM120. By using 2 pcs U-bolts M8 around the rectangular pipe, the clamp -saddle, resp. the diffuser will be fixed. The fixing has to be done by symmetrically tightening with washers and self-locking nuts M8 to ensure a firmly, horizontally and right-angled mounting. The threads of the U-bolts must be lubricated beforehand to avoid seizing. Starting torque is 4 Nm and has to be increased until clamp saddle is drawn down to the rectangular distribution pipe and the diffuser is safely tightened. OPERATION INSTRUCTIONS Functional check and leak test After the oval membrane tube diffusers PERMOX OM120 have been installed, a function check and leak test must be performed. In order to do this, the tank has to be filled up to a level of approx. 10 cm above the top edge of the diffuser with clean water. To check the function visually, the diffusers should be loaded with the specified amount of air (see load table on last page). After ensuring that all diffusers are working well, the air flow can be reduced (min. specific load in table on last page) in order to make it easier to perform the leak test. Rising large bubbles indicate leaks (e.g. due to gaskets that have been dislodged). Those must be remedied. The successfully performed functional check and leak test must be documented. The water level has to be raised to at least 100 cm above the top edge of the diffuser as quickly as possible. Important: the air flow shall not be stopped between these afore noted tests and following diffuser run-in! Diffuser run-in The compressed air must not be turned off between the functional check, resp. leak test and the run-in of the diffusers. Oval membrane tube diffusers PERMOX OM120 with EPDM membrane must be operated continuously for at least 60 hours with the specified specific load (see run-in of diffusers on last page) before performing a conclusive oxygen transfer test. Bubble pattern test The bubble pattern shall be assessed first after the above-described run-in of the diffusers has been completed. For this purpose the diffusers have to be operated from the maximum down to the minimum specific load (see load table at last page). The evenness of the aeration (bubble pattern test) has to be checked when the tank is filled to a level of at least 100 cm of water above the diffuser top edge. Checking the evenness of the aeration is only possible at a water temperature of above 10 C.

Oxygen transfer test Supratec Prior to carrying out an oxygen transfer test as a proof of the efficiency of the oval membrane tube diffusers PERMOX OM120, afore mentioned steps must have been completed. The oxygen transfer test can be carried out in accordance with the accepted regulations (e.g. DIN EN 12255-15 2003 or DWA-M 209) using the fresh water or waste water method. Specified warranty values must be rigorously adhered to. A calibrated and exact measurement of the air volume is required. Commissioning If commissioning is delayed it must be ensured that the diffusers are sufficiently covered by water (at least 100 cm) so that oval membrane tube diffusers PERMOX OM120 are protected against strong sun, frost and mechanical damage caused by falling objects, for example. MAINTENANCE INSTRUCTIONS The oval membrane tube diffuser PERMOX OM120 is a low-maintenance system and is partially self-cleaning due to the different specific air loads during the normal operating cycle. Depending on the operating conditions we recommend an appropriate maintenance cycle. This maintenance cycle is also used for removing deposits after longer periods of inactivity and long-term operation with low specific loads. Maintenance cycle Any deposits are removed by short-term load-dependent changes of the membrane extension. This also prevents any accumulation of biological growth. For PERMOX Om120 we recommend a daily and no less than weekly maintenance loading (see load table on last page) of approx. 15-30 minutes. Monitoring The bubble pattern and the pressure loss should be checked and documented at regular intervals under similar operating conditions (such as water level and air quantity). The pressure loss development in the load-dependent, seasonal comparison makes it possible to evaluate the condition of the diffuser objectively. In the event of significant changes of the bubble pattern and/or pressure loss, Supratec must be consulted immediately. Particularly in the case of systems that are operated intermittently, there is a risk that damaged diffusers can allow the ingress of waste water into the entire pipework system. This will adversely affect the function and service life of all diffusers.

Cleaning Supratec The condition of the diffusers must be checked whenever the tank is empty. Particular attention must be paid to soiling (deposits, sludge, etc.), which can usually be easily removed from the membranes. Depending on the type and composition of the soiling, one of the following methods or a combination of several methods might be required. Testing for compatibility and successful results must always be carried out first on individual membranes (particularly with alkalis and acids). We recommend: - Manually: Cleaning with water and a soft brush is often sufficient for removal of existing deposits - Alkaline solutions: Soapy water can usually be used to support manual cleaning. - Acids: In some cases (e.g. limescale) the membranes must be cleaned by adding acids to the compressed air (see below). Acid dosing In systems in which limescale deposits are expected, we recommend to clean those systems with diluted acid (85% formic acid for EPDM) at regular intervals. If necessary, diluted acid is dosed into the compressed air in order to minimise the pressure loss of the membrane and increase the service life of the diffuser. For this purpose, we offer a mobile acid dosing station. Please contact Supratec for further information. Load table Oval membrane tube diffuser PERMOX OM120 EPDM [ /h per meter] Functional check 8 Diffuser run-in prior to the oxygen transfer test (at least 60 hrs.) Bubble pattern (starting with higher specific load) Minimum specific load (0 /h /m or ) 12 3-12 1 Nominal operating range 4-12 Maximum continuous load / maintenance load 15 (We reserve the right to make technical changes.) Our QMS is certified in compliance with DIN EN Norm ISO 9001