Oxygen Measurement in Natural Gas

Similar documents
DEVICES FOR FIELD DETERMINATION OF WATER VAPOR IN NATURAL GAS Betsy Murphy MNM Enterprises 801 N. Riverside Drive Fort Worth, Texas 76111

Dissolved Oxygen Guide

Columbus Instruments

Detector Carrier Gas Comments Detector anode purge or reference gas. Electron Capture Nitrogen Maximum sensitivity Nitrogen Argon/Methane

DF-310E PROCESS ANALYSERS APPLICATIONS FEATURES

Dissolved Oxygen and measurement possibilities. Berno Lüpkes, 15 th March 2017

OXY Integral. INTERCON ENTERPRISES INC Tel: Fax: Internet:

DF-550E PROCESS ANALYSERS APPLICATIONS FEATURES

Potter Nitrogen Generators

Triton DO8 Dissolved Oxygen Sensors ELECTRO-CHEMICAL DEVICES

Materials Performance November Nitrogen generator inhibits corrosion within fire protection systems

Vortex flowmeters. Product family introduction Principle of operation Product review Applications Key product features

Application Note AN-107

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Engineered Solutions, Guaranteed Results.

Best Practices for Installation of Gaseous Sample Pumps

The Helium Leak Detector

White Paper. Chemical Sensor vs NDIR - Overview: NDIR Technology:

A review of best practices for Selection, Installation, Operation and Maintenance of Gas meters for Flare Applications used for Managing facility

Level MEASUREMENT 1/2016

Oxygen & Binary Gas Measurement and Analysis

OPERATOR S MANUAL Ar-Gone Weld Gas Analyzer

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Custom solutions for your analytical needs.

Both physical and chemical effects come into play either separately or in combination.

MODEL GT820 OXYGEN SENSOR

Oxygen measurement in diving technology

Oxygen Measurement Systems High Reliability and Wide Application Coverage

Selecting the right pressure sensor for your application

ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 15 INERT GAS SYSTEMS

ATEX VACUUM PUMPS AND GAUGES CHEMICALLY RESISTANT, OIL-FREE AND SAFE

Title: Standard Operating Procedure for Measurement of Ethylene (C 2 H 4 ) in Ambient Air by Reduced Gas Detection (RGD)

Laser Spectrometers for Online Moisture Measurement in Natural Gas. Ken Soleyn GE M&C

Sampling Considerations for Equilibrium Dissolved Oxygen [DO] Sensors

Generating Calibration Gas Standards

Improve Process Reliability

Inert Air (N2) Systems Manual

WBEA Standard Operating Procedure

STERILIZABLE DISSOLVED OXYGEN SENSORS

Nemoto Sensor Engineering Company Ltd

Exercise 5-2. Bubblers EXERCISE OBJECTIVE DISCUSSION OUTLINE. Bubblers DISCUSSION. Learn to measure the level in a vessel using a bubbler.

OxiQuant S. Operating Instructions

The New PHD 4 Portable Helium Detector

better measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars.

NEULOG OXYGEN LOGGER SENSOR GUIDE

FUNDAMENTALS OF PRESSURE REGULATORS ROBERT BENNETT MANAGER OF TRAINING ELSTER AMERICAN METER

Advantages of Carrier Gas Leak Detection using Novel Helium or Hydrogen Leak Detectors with Specific Sensor Types

FAS-W. Features. Applications. Automatic condensation hygrometer

Online DGA-monitoring of power transformers

2 Sentry MCL Installation, Operation & Maintenance

TECHNICAL ADVISORY Helium Enhanced Oxygen Monitoring Aberration Phenomena July 20, 2001

Leaks, contamination and closed loop control how RGAs make coating processes more profitable

EasyLine Continuous Gas Analyzers. So smart, they re simple

SF 6 Product Guide. Gas Analysis Instruments and Accessories

2017 Award Nomination

Gases&Technology. Measurement of Impurities in Helium Using the Dielectric Barrier Discharge Helium Ionization Detector. FEATURE.

Optimizing Gas Supply for Industrial Lasers


Superior Result from Analytical Instruments The constant purity of the nitrogen improves system stability and ensures reproducible results

UV Curing in an Inerted Atmosphere Equipment Update

The Principles of Vacuum Technology

Improving distillation tower operation

OPERATION MANUAL NTF-15

METHOD 21 - DETERMINATION OF VOLATILE ORGANIC COMPOUND LEAKS. 1.2 Scope. This method is applicable for the

CCS240 and CCS241. Technical Information. Sensors for chlorine dioxide Amperometric, membrane-covered sensors for installation in the CCA250 assembly

SERIES 30. Spring Operated Tank Blanketing Valve PROTECTOSEAL.

WP Eliminating Oxygen from the Purge Gas and the use of Monitoring Equipment

Focus on VOC Emissions Reduction Using an Oxygen Based Inerting Control System For Inert Gas Blanketing of Chemical Process Vessels

ENSURING AN ACCURATE RESULT IN AN ANALYTICAL INSTRUMENTATION SYSTEM PART 1: UNDERSTANDING AND MEASURING TIME DELAY

This test shall be carried out on all vehicles equipped with open type traction batteries.

A Journal of Practical and Useful Vacuum Technology. By Phil Danielson

EASIDEW TRANSMITTER with Current Source Output

Constant Pressure Inlet (CCN) Operator Manual

Gases and welding distributors continue

h2000 plus HyDROGEN LEAk DETECTOR

Leak Checking Large Vacuum Chambers

Oxymax W COS41. Technical Information. Potentiostatic amperometric two-electrode sensor Long-term stable sensor for water and wastewater applications

STEAM STERILIZABLE POLAROGRAPHIC OXYGEN ELECTRODE

Applications Note: Use of "pentane equivalent" calibration gas mixtures

OPERATION MANUAL NTF-60 Plus

TECHNIQUES OF COMPOSITE SAMPLING. Kris Kimmel. YZ Systems, Inc Pollok Drive Conroe, Texas 77303

HiQ laboratory gas generators.

The Experts in Vacuum Solutions

H 2. Sensor Series Take no risk! Install a Hydrogen Sensor in your Gaschromatograph

GPR-1100 ATEX Portable PPM O 2 Analyzer

Thank You for Attending Our June Webinar

INSTALLATION & MAINTENANCE INSTRUCTIONS

The latest automotive systems require innovative leak test methods and fixturing.

Tank Blanketing. Application Jordan Valve Product Offering Competition

Calibration Requirements for Direct Reading Confined Space Gas Detectors

Gas density monitor With integrated transmitter Model GDM-100-TI

CompAir provide high quality and reliable Nitrogen solutions

Zebron Gas Management

Improve Reliability of Turbomachinery Lubrication and Sealing Systems

Diagnosing EVAP systems By: Bernie Thompson

Electrochemical Sensor

Gas Measurement Fundamentals Certification. Curriculum

METHOD 25A - DETERMINATION OF TOTAL GASEOUS ORGANIC CONCENTRATION USING A FLAME IONIZATION ANALYZER

Calibration Gas Instrument INSTRUCTION MANUAL. Release I. Advanced Calibration Designs, Inc.

Nemoto Sensor Engineering Company Ltd

What I have learned about SF 6 gas testing.a Practical explanation

Committee on NFPA 85

Transcription:

Oxygen Measurement in Natural Gas Application Background Natural Gas Fuel is primarily methane. If it were pure methane, it would be very simple to transport and use. But it comes out of the well as a mixture of many different chemicals, many of which are considered contaminants in this fuel. After sweetening (removing the acidic components, CO 2 and H 2 S), processing and transporting the gas, Oxygen (O 2 ) is usually listed as one of these contaminant gases. Oxygen in the pipeline is a contaminant for any customer in this supply chain because oxygen reacts with the other constituents of the gas. This document will address measuring oxygen in the natural gas fuel. At the end of the pipe the fuel is burned. This is also where oxygen plays a major role in this industry. Ensuring there is sufficient O 2 for complete combustion, while limiting the parasitic heat loss of heating the combustion air, can help to maximize the efficiency of the burner. Where Does The Oxygen Come From? In the natural gas well, oxygen is a rare occurrence and then only in extremely small concentrations. There are significant sources for the O 2 content in the pipeline. Leakage, maintenance activities, and vacuum extraction processes are the main methods that introduce O 2 into the gas pipeline stream. The problem with the presence of oxygen in this fuel has increased because producers use vacuum to extract as much natural gas as possible from plays that are nearly depleted. Vacuum pumps exacerbate the issue of leakage and have the potential to pull air into the inlet of the compressor as well as into the fuel. Keep in mind the scope of the volume of gas involved in this industry as many pipelines can carry enormous quantities of gas daily at very high pressures. If the gas contains 0.2% oxygen, it can be a very large volume of this contaminant and still be within specification. Oxygen also comes from leaks in the pipeline or in processing equipment. Leakage of O 2 into the pressurized gas is not as intuitive, since the escaping gas won t totally prevent the outside environment from ingressing against it. The issue is one of relative vapor pressure. The problem happens when the vapor pressure of oxygen in air, which is roughly 157 mmhg, and the oxygen vapor pressure inside the pipe at 1000 psig with 200 ppm V oxygen is just 10.5 mmhg. This represents a pressure ratio of nearly 15:1 pushing the oxygen into a leak in the pipe even at 1000 psig.

Maintenance activities can be sources of additional leakage and contamination. Pipelines and processing equipment should be isolated if possible to reduce this contamination and ingress of air into the process/pipeline. Once the maintenance activity has been completed, the equipment should be purged with an inert gas, e.g. argon, which is not reactive, or natural gas. At the point of use the mixture of fuel to air is critical. The O 2 comes from the ambient air to support the combustion process. Large natural gas customers concern in burning is efficiency so monitoring the O 2 content in the exhaust of the burner is a measure of the efficiency. This measurement also provides a safety alert should the O 2 level fall below a lower limit. Why Is O 2 Measurement Important? There are several reasons why O 2 is undesirable in natural gas. These reasons drive the need to monitor this contaminant. O 2 does not add to the heating value of the gas and is not of benefit. O 2 combines with other chemical gases, especially H 2 S, to form acids. O 2 degrades amine, which inhibits the process of removing CO2 and H 2 S from the gas chemically. O 2 can degrade some mercaptans reducing the effectiveness of these odorants in the gas. O 2 accelerates corrosion in the mechanical components that come in contact with the gas. Monitoring the oxygen content of this fuel to alert to a potential danger from this contamination is a critical measurement. Limits vary globally and from tariff to tariff ranging widely from a maximum of only 10 ppm to <1% by volume. North American maximum limits are generally found to range from 0.1 to 0.2% by volume. The industry appears to be moving these limits downward across the board due to oxygen s detrimental impact on the gas infrastructure and the economics of processing. Keep in mind that while using any measurement method, humidity will change the reading. According to Dalton s Law, moisture displaces other molecules and inversely impacts the O 2 concentration.

Current Measurement Methods: There are several methods for oxygen measurement in Natural Gas applications. The most common measurement methods are: Galvanic (dry electrochemical) Method Coulometric (wet electrochemical) Method Paramagnetic Method Fluorescence Quenching Method (Oxygen Optode) Gas Chromatography Method Galvanic Method Operation This galvanic sensor (dry electrochemical, coulometric or echem method) is analogous to a dry-cell battery that produces a small current in the presence of oxygen. A porous membrane allows the sample to contact the cathode, made of a noble metal, usually gold or silver. The O 2 is reduced by the oxidation of the anode of lead. This cell also contains an electrolyte paste to allow the conduction of the electrons to form the battery. The electrical connections allow the current flow and measuring this current determines the oxygen content at the cell. Sensor Life This is consumable sensor where the anode is consumed or oxidized during its use at a rate dependent on the quantity of O 2 in the gas. These cells are often sold for the range of oxygen to be measured. To extend cell lifetimes, additional lead is often used for the higher O 2 ranges. Interferences These cells are immune to interference by most gases. CO 2 reacts with the electrolyte in most KOH based sensors and is usually not recommended above a few ppm of CO 2. Acetic acid based sensors are available for use in backgrounds with more than 0.5% CO2 present. Temperature is compensated using a temperature sensor and algorithm for the final reading. Pressure will have little impact if it is equal on both sides of the sensor. Rapid pressure changes are certainly not recommended.

Coulometric Method Operation This coulometric sensor (Clark Cell, amperometric, wet electrochemical or polarographic method) is analogous to a wet-cell battery that produces a small current in the presence of oxygen. In other words, there is a chemical ion exchange where the current flowing under an applied excitation between two electrodes in a solution is enabled by oxygen. Like the galvanic cell above, a porous membrane allows the oxygen to diffuse into the wet cell. The cell is filled with a KOH solution where the anode, made of a noble metal, usually silver, and the gold cathode are mounted. The oxygen in the sample is electrolyzed and moved from the cathode to the anode driven by an applied voltage. The current is directly related to the concentration of oxygen in the sample. The electronics scale and translate this current into a useable value. The cell reacts quickly to changes in oxygen in the sample and is not consumed in the process. The analogy of the dry-cell vs. wet cell batteries is similar where the wet-cell is rechargeable and the old style dry-cell is not. Sensor Life Because the electrodes are not consumed during the measurement or exposure to oxygen, this cell has a long life reaching 5 years of service in many applications. To prevent cell damage, the level of the KOH solution must be maintained by adding distilled water. Interferences Although even moderate concentrations of acid gases can damage the cell, additional protective electrodes can be installed to minimize these acidic chemical effects. Paramagnetic Method Operation The Paramagnetic Method uses an unusual property of oxygen molecules - they can be attracted by a strong magnetic field. The sensor is essentially measuring the displacement of other gases by the concentration of the O 2 molecules. Magneto-dynamic sensors have glass spheres filled with nitrogen that would be displaced by the concentration of O 2 in the strong field. Current through a coil to counteract this force is proportional to the O 2 content.

Thermo-paramagnetic cells have no moving parts and are able to detect the flow of a molecular wind using a hot wire detection technique. The wind is created as the oxygen molecules attracted to the strong magnetic field inside the cell find a heated escape route of heated thermistors. This heated gas transfers some of that heat to a sensing thermistor and this transfer is proportional to the flow of gas, i.e. oxygen concentration. For use in hazardous/classified locations the cell is mounted in a suitable enclosure. Sensor Life There are no consumables in this sensor and the drift rate is very low. Sensor lifetimes are limited only by the presence of any corrosive components in the gas and by accumulations of particulates. Interferences Any background gas that is present in the sample that differs from the calibration will have an effect on the measurement. This can be remedied by an offset in the field adjustment or calibrated out in the factory. Oxygen Optode or Fluorescence Quenching Method Operation Many chemicals have the property of fluorescence, i.e. they can be excited by an external source to produce this luminescence. Some of these same materials lose this property in the presence of other nonassociated chemicals. Specific to the measurement of oxygen, a specific chemical deposit/dye of an optical fiber gives an opportunity to measure the O 2 content in a sample. The sensitive chemistry is either coated onto an optical fiber, or the tip of the fiber is dyed with the chemical. As all fluorescent materials require excitation, the optical fiber is excited by pulsing it with a laser light of the required wavelength. Between the pulses of light, the light generated by the chemical fluorescence is measured by a spectrometer. Oxygen content of the sample counteracts the fluorescence in a proportional way. The more O 2, the less light is generated from exciting the chemical to fluoresce. This light is more sensitive at low levels of oxygen in the sample. Sensor Life Sensor lifetime is good, but it is often recommended that it be reconditioned annually for best performance. Any chemical interaction that might impact the chemical dye will cause the sensor to lose its ability to measure accurately.

Interferences Since this sensor depends on the density of the O 2 molecules it is pressure and temperature sensitive and these effects must be compensated. Samples that contain particulates can cause backscatter and interfere with the accuracy. Proper sample handling is essential because any sensor contamination that slows equilibration will slow response speed and may cause significant errors. Gas Chromatography Method Operation GCs can provide the oxygen content in natural gas but require an additional molecular sieve column to discriminate O 2 from any nitrogen in the gas. This measurement method does not provide this data point in the standard GC configuration for BTU analysis, but requires that accessory column along with its supporting valve system. Cycle times for the GC are extended to provide the time for the O 2 analysis. The installed base of field GCs is very large because they are used to determine the heating value of the gas. Very few of these have the required column installed and most cannot be retrofitted for this feature. In addition to the special column and valving, the calibration gas mixture is also required to contain a representative concentration of oxygen in the mixture. Calibration gas must be used in order to ensure that the GC remains accurate. Field GCs can detect down 0.01% O 2 LDL so they would detect the minimum concentration needed to meet most tariff quality specifications with the smallest range of 0-1% O 2. Sensor Life Sensor lifetime is governed by the sample quality provided to the chromatograph. If even a slightly contaminated sample is supplied to the columns, they will eventually plug and lose their ability to provide accurate sample analysis. Interferences Without the correct column and proper sample conditioning system, nitrogen can strongly influence the data peak where oxygen is found. This is due to their proximity and drives the need for a special column to separate these two gases ahead of the detector.

Current Measurement Methods Summary: Method Positive Points Negative Points Coulometric High accuracy and stability Long sensor life Acid gas resistance with optional additional electrodes Can handle oxygen shock Fast response No false low readings Mid-range pricing Requires rebuilding to clean the anode every 5-6 years Electrolyte needs to be replenished regularly with distilled water Longer warm up time Low pressure only, some to 100 psig max. Fluorescence Quenching Galvanic Gas Chromatography Paramagnetic Fast response Immune to H 2 S No interferences in natural gas Reliable Minimal Maintenance Long sensor Life Easy to calibrate Fairly easy to use Portable, light and easy to power from batteries This technology is competitive so cells are plentiful Low initial cost relative to other technologies Robust sensor Sensing is independent of an external power source Short warm-up time Pressure to 30 atm if both inlet and outlet are at equal pressure Familiar instrument to Instrument Technicians Consolidates measurements into one instrument Medium priced instrument Sensors can be calibrated on-site using a calibration gas source plumbed to the sensor or air. Higher initial cost Requires temperature and pressure correction Sensor will not tolerate chemicals that attack the fluorescent coating/dye Sample pressures to 200 psig Being a consumable transducer, the instrument needs monthly, or even more frequent, calibration. Can become slower to respond as the cell ages. Cells exposed to high oxygen levels including exposing the cells to the atmosphere fail prematurely. Cells fail low or Unsafe giving a false sense of security. High oxygen exposure translates into longer recovery time to return to a normal low reading Cells cannot tolerate overpressure or vacuum when there is a significant pressure differential between the inlet and exhaust. H 2 S degrades the sensor components a scrubber needs to be fitted. Sensors/cells have a limited shelf life. Atmospheric pressure operation is recommended. Higher instrument cost and complexity Calibration gases are more expensive Lower detectible limit is ~100 ppm V Low pressure only Can be sensitive to changes in the flow rate of the sample gas The presence of minute particulates and moisture can interfere with the accuracy in some designs

Sampling for Oxygen Measurement in Natural Gas In natural gas, sampling is required with all oxygen measurements due to the lack of pressure capability of all these sensing technologies. Optimal performance of all the technologies above can be achieved by controlling pressure, flow and temperature, as well as having a clean sample free from liquids. Sample systems should include the following basic characteristics: Sample probe per API 14.1 with optional pressure reduction and filtration/liquid rejection Short Sample lines High bypass or fast loop design to maximize speed of response Liquid removal with membrane bypass filters Particulate filtration Pressure regulation using a heated regulator to manufacturers specification Flow control to manufacturers specification Temperature control within the sample system enclosure for minimum drift Minimum components to reduce incidence of leakage Ability to easily valve in a calibration gas to the sensing element Block and bleed valving for safe servicing All of these issues should be addressed in the design of the sample system for oxygen measurement in natural gas. Stabilizing all possible variables will aid in the accuracy and stability of all sensing elements. Michell s Solution: Measuring Correctly Thermo paramagnetic analyzer Use a thermal paramagnetic transmitter connected to the natural gas sample from the pipeline. The sample system must include pressure reduction and membrane filtration to ensure a clean gaseous sample to the sensor. How should the instrument be connected? The connections for the analyzer should be simple - from a pressure reducing sample probe in the pipeline to the sample system as described below. This system includes the membrane filter ahead of the XTP601 then the sample is exhausted to a vent or flare. For added convenience a calibration gas can be connected but should have no path for the calibration gas to return to the pipeline (see flow diagram on the next page.)

Cost justification: What can happen if the O 2 is not monitored correctly? If oxygen level is too high in the gas: Corrosion can substantially decrease the life of the pipeline and/or gas processing components. O 2 degrades amine which inhibits the process of chemically removing CO 2 and H 2 S from the gas It can degrade some mercaptans reducing the effectiveness of these odorants in the gas. All of these important issues can become very expensive if O 2 is not monitored and much more costly than installing an oxygen measuring system so that proper operation is maintained. What should be used for this application Use an XTP601 with a sample system and choose any additional options or accessories that may be needed. Consult with your Michell Representative for sample system recommendations.