GIRARD EQUIPMENT, INC. Specialty Valve Manufacturers for Tank Trailers since 1952

Similar documents
INSTALLATION INSTRUCTIONS. CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION

Type S301 & S302 Gas Regulators INTRODUCTION INSTALLATION. Scope of Manual. Description. Specifications. Type S301 and S302. Instruction Manual

ANDERSON GREENWOOD SERIES 9000 POSRV INSTALLATION AND MAINTENANCE INSTRUCTIONS

Type ACE97. Introduction. Installation. P.E.D. Categories. Specifications. Overpressure Protection. Installation Guide English May 2002

1200B2 Series Service Regulators. Instruction Manual

WHEATLEY WHEATLEY SERIES 500 SWING CHECK VALVE. Installation, Operation and Maintenance Manual

Installation, Operation and Maintenance Manual for Back Pressure Regulator

Pressure Dump Valve Service Kit for Series 2300 Units

Installation, Operation, and Maintenance Manual

Product Manual. Description. Specifications. CVS Type 1301F and CVS Type 1301G Regulator. Introduction

SALCO PRODUCTS, INC. PRESSURE RELIEF VALVE STORAGE, INSTALLATION, OPERATING, MAINTENANCE/TESTING, AND INSPECTION INSTRUCTIONS

1800C and 1800C-HC Series Service Regulators

APCO ARV CLEAN WATER AIR RELEASE VALVES. Model 50A

MEGR-1912 Instruction Manual

GREIG FILTERS, INC. OPERATION MANUAL

WHEATLEY Series 500 Swing Check Valve

SPECIFICATIONS. Approximate Weight: 10 oz. Surface Finish: Ra micro inch or less MATERIALS OF CONSTRUCTION

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER RELIEF VALVE

Model 7989T Steel Pipe Squeezer Sch. 40 & Sch. 80. Operations Manual

Anderson Greenwood Series 93 Positive Pressure POSRV Installation and Maintenance Instructions

Alkylphosphines. Storage and Handling Recommendations

Full Internal Relief Valves Instruction Manual

SERIES 30. Spring Operated Tank Blanketing Valve PROTECTOSEAL.

Instruction Manual Pressure Relief Valve and Rupture Disc Chlorine or Sulfur Dioxide, Series 869

Pressure Dump Valve Service Kit for Series 3000 Units

Horizontal Bladder Tanks

Vertical Bladder Tanks

Operation Manual. Diaphragm Sensed Gas Pressure Regulators

MODEL PAF 450 ASSEMBLY

FOR INSTALLING CO 2 BLENDER KIT (P/N IN BEER SYSTEM

LARGE DRY CHEMICAL, TWIN-AGENT, AFFF, HALON 1211, AND AQUASONIC (NITROGEN-OPERATED SYSTEMS) Pressure Regulator Test Manual

Types 95L and 95H Pressure Regulators

Adjustable. Unloader Valve. O&M Manual. Part #

1805 Series Relief Valves

INSTALLATION, MAINTENANCE & OPERATING INSTRUCTIONS 2-4 REDUCED PORT/ FULL PORT (5700/6700) ANSI CLASS 150/300/600/900/1500/2500 TRUNNION BALL VALVES

Vertical and Horizontal Bladder Tanks

Models 461-S, 461-8S and S Regulators. R-1330 Rev. 7

Model MTB-ASME Vertical Bladder Tanks

CATALOGUE // The Fort Vale Range of Equipment to suit Hydrogen Peroxide Tank Specification. Fort Vale Engineering Ltd. 2009

Model MTB-ASME Vertical Bladder Tanks

Model MTB-ASME Horizontal Bladder Tanks

Model Secure-Gard Pilot Operated Vent Valve SECTION II. Remove all packing material inside and outside of the valve prior to installation.

Safety relief valves Type SFA 15 and SFA 15-50

D05 Pressure Regulating Valves

for for Industrial Refrigeration

Safety relief valves Type BSV-8

TITAN FLOW CONTROL, INC.

Types S100K and S102K Pressure Regulators

Hydraulic Piston Accumulators

Operation Manual Piston Sensed Gas Pressure Regulators

WHEATLEY Series 822/820 Swing Check Valve

Regulator from 1800 B series

LEAK SEALING SYSTEMS

29 SERIES - SAFETY VALVE

Warning: NEVER ALTER TEST EQUIPMENT

SCA Series Inverted Bucket Steam Traps

Installation, Operation, and Maintenance Manual

NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE

Type ACE95jr Tank Blanketing Valve

Differential Pressure Regulator Type Type 45-6 (0.1 to 1 bar, DN 15) Mounting and Operating Instructions EB 3226 EN

Gas Lines. Technical Manual. Sumitomo (SHI) Cryogenics of America, Inc Vultee Street Allentown, PA U.S.A.

299H Series. Introduction. P.E.D. Categories. Specifications. Installation. Warning. Installation Guide English September 2012

S300 Series. Valve Link. Features. Fisher Controls

Type CT88 Backpressure Regulator

627 Series Pressure Reducing Regulators

Type ACE97 Pad-Depad Valve

Types 749B and R130 Changeover Manifolds

TECHNICAL DATA. Q= Cv S

627 Series Pressure Reducing Regulators

Summary of Accumulators These operating instructions apply to the accumulators listed in the table shown below.

PRO-50 Instrument Supply Regulator

Safety relief valves, type SFA 15 REFRIGERATION AND AIR CONDITIONING. Technical leaflet

OPERATING AND MAINTENANCE MANUAL

DS06D,G Dial Set Pressure Regulating Valve

PILOT OPERATED RELIEF VALVE SAFETY PRODUCTS THAT PROTECT EQUIPMENT, LIVES & THE ENVIRONMENT

ROTATING DISK VALVES INSTALLATION AND MAINTENANCE 1. SCOPE 3 2. INFORMATION ON USAGE 3 3. VALVE TYPES 3 4. OPERATORS 5 5. VALVE CONSTRUCTION 6

EASTERN ENERGY SERVICES PTE LTD. 60 Kaki Bukit Place #02-19 Eunos Tech Park Singapore, SG Singapore Telephone: Fax:

Type 1367 High-Pressure Instrument Supply System with Overpressure Protection

MEGR-1627 Instruction Manual

Sterile Visual Flow Indicator

TECHNICAL DATA. Q = C v P S

Eaton Filtration, LLC

INSTALLATION, OPERATION AND MAINTENANCE MANUAL. Model Sanitary Vent SECTION I

DS05C,D,G Dial Set Pressure Regulating Valves

Armored Gauge O S & Y Bolted Bonnet Valves Series BB-100

Hydrostatic Pressure Testing

Choosing the right miniature instrument and control valve is a snap

Types S108K and S109K Pressure Reducing Regulators with Integral Slam-Shut Device

2.0 INSTALLATION & SERVICE

Safety relief valves SFV 20-25

Eaton Filtration, LLC

Safety relief valves Type SFV 20-25

1305 Series Pressure Reducing Regulators

INSTALLATION / OPERATION / MAINTENANCE INSTRUCTION

PP-1, PP-1W, PP-2, & PP-3

TECHNICAL DATA 3 MODEL G-3000 DRY VALVE RISER ASSEMBLY

TBV OPERATION AND MAINTENANCE MANUAL SERIES 2800: FLANGED BALL VALVE. For technical questions, please contact the following:

Instruction Manual Updated 7/26/2011 Ver. 2.2

64 Series Pressure Reducing Regulators

Pressure Reducing Valve DMV 755

Transcription:

Pressure Testing Girard DOT407 Pressure Relief Vents GIRARD EQUIPMENT, INC. Specialty Valve Manufacturers for Tank Trailers since 1952 908-862-6300 Toll Free 800-526-4330 FAX 908-862-8178 Website: www.girardequip.com E-MAIL: gsales@girardequip.com Rev.7/8/13

Girard Equipment, Inc. General Information The following information is for information only. It is not designed to replace technical bulletins from TTMA, NTTC, DOT, association or other regulatory commission. It is intended for use as a guide to vent testing in HM-183. It does not replace the requirements of the Federal Register, Section 49 CFR Part 107 et al, entitled Requirements for Cargo Tanks. The suggestions contained here are our interpretation of the requirements and, as such, are open to other interpretations. Girard Equipment, Inc. will take no responsibility for deletions or misinterpretations. The NTTC (National Tank Truck Carriers) offers an exceptional guideline to the care and maintenance of tank trailers. The address and phone number is as follows: National Tank Truck Carriers, Inc. 2200 Mill Road Alexandria, VA 22314-4677 (703) 838-1960 Fax (703) 684-5753 www.tanktruck.org Before testing please check the specification data plate to ensure which code applies to that tank trailer. Record the Tank and Vent MAWP and Set Pressure before performing a bench test. We strongly recommend that you thoroughly clean the valve and replace the O-ring seat prior to testing. This may save you time. See illustration #1 for MAWP and settings information before attempting a bench test. Always use Safe shop practice and wear eye protection when performing bench testing of DOT 407 Vents. Rev.7/8/13

DOT407 VENT BENCH TESTING As prescribed by 180.407(d)(3) of the External Visual Inspection Remove the vent from the tank. Make sure the vent is free from any foreign matter. Place Vent on the tester and proceed to testing procedures: Testing Procedures 1. Close the blow down valve. 2. Slowly open air input valve until needle on the pressure gauge at the rate of the second hand on your watch (approx. 1 pound per second). 3. Place hand around vent seat area to feel any escaping air. Listen for any air escaping and watch air gauge to see when the upward movement stops. When the gauge stops record the pressure, this is the SET PRESSURE. 4. Close the inlet air valve and watch gauge. The gauge needle will back down slowly and will stop this will be RESET PRESSURE. M.A.W.P SET PRESSURE (MARKED ON VENT) SET PRESSURE (VENT MUST OPEN BETWEEN 120% and 132% of MAWP) 1 RESET PRESSURE (VENT MUST RESET AT 90% OF START TO DISCHARGE) 2 25 30 30 33 27 3 30 36 36-39.6 32.4 4 35 42 42 46.2 37.8 5 40 48 48 52.8 43.2 6 1 Per 178.345-10 2 Per 180.407(d)(3) 3 Cannot be less than 27 4 Cannot be less than 32.4 5 Cannot be less than 37.8 6 Cannot be less than 43.2 Rev.7/8/13

M.A.W.P. DOT407 Designation for tank working pressure stamped on the data plate and stamped on vents. Set Pressure The pressure in which the vent will open to relieve (Start to Discharge) pressure. (DOT407 = 120%-132% of M.A.W.P) Reset Pressure The pressure in which the vent will close. (Reseat to Leak (DOT407=90% of Set Pressure) Tight Condition) Remote Pressure Gauge Quick Connections Blow-down Line Shop air regulated to 60 P.S.I. Section 180 (on Tank Test) for MC 307 DOT407 Venting All venting must not leak at 80% of design pressure (MC307 Tanks) or 80% of M.A.W.P. (DOT407 Tanks) when tank is pressurized with vent in place. Tank Design Pressure Not to leak below (p.s.i.g.) (M.A.W.P.) (5 Minutes) 25... 20 30... 24 35... 28 40... 32 Rev.7/8/13

4 Low Profile DOT 407 VENT Function Girard Equipment, Inc. s Low Profile DOT 407 Vents combine a low profile, light weight design with increased flow rates to meet the most demanding needs of virtually any DOT 407, DOT 412, MC 307 and MC 312 tank. See the table below for specific flow rates. The stainless steel valve seat seals on a Teflon encapsulated silicone O Ring. This O Ring provides complete chemical resistance and a bubbletight seal to meet the latest DOT requirements. The unit also meets the surge requirements of 178.345-10 (b) (3). DOT 407 LT: Weight: 10 lbs. Installed Height: 51 2 over the top of the pipe nipple. 6 STYLES 402011L Gasket 4TR 402012L 402014L Gasket 4CFE DESCRIPTION DOT407LT Vent with a 4 N.P.S. female pipe thread. Attaches to a 4 pipe nipple and seals against a solid Teflon ring gasket. DOT 407LS Stub end vent. Lower housing terminates in a straight stub end. Designed to be welded to the tank shell. DOT407LF Vent to mount on a 4 TTMA flange. Supplied with a 3 8-16 removable thread inserts and a Teflon envelope flange gasket. DOT 407 LF: Weight: 13 lbs. DOT407 LAF: Weight: 19 lbs. 6 5 16 6 5 8 402015L Gasket 402016 DOT407LAF Vent to mount on a 4 ANSI flange. Supplied with a Teflon envelope flange gasket and a 1 4 NPT Tell-Tale indicator tap. DOT407 LS: Weight: 14 lbs. 9 O.D. PERFORMANCE SPECIFICATIONS MAWP Test Flow Exposed Pressure (SCFH) Surface 25 40 374,512 737 25 45 431,308 946 30 45 431,308 946 35 52.5 484,718 1156 7 7 8 MATERIALS OF CONSTRUCTION 7 1 2 O.D. All metallic parts Stainless Steel O Ring Teflon encapsulated silicone Gasket Teflon www.girardequip.com Linden, NJ, 800.526.4330 Houston, TX, 281.532.1800 Chicago, IL 847.599.8566 A3

4 Low Profile DOT 407 VENT ITEMS PART NUMBER DESCRIPTION 1 1 402019 Plug 2 402003L Rain Cover 3 402004L Low Profile Upper Housing Specify MAWP 2 4 402005 Spring (for MAWP < 45 only) 402005HP Spring (for MAWP > 45 only) 5 402006LN Low Profile Poppet with Nut 6 402007 Teflon Silicone O Ring 7 402011L 4 LT Model Lower Housing 3 8 4TR Solid Teflon Gasket 9 402012L LS Model Lower Housing 10 402014L 4 LF Model Lower Housing 11 4CFE Teflon Encapsulated Flange Gasket (TTMA) 12 402015L 4 LAF Model Lower Housing 13 402016 Teflon Envelope Flange Gasket (ANSI) 7 5 6 4 9 8 10 11 12 13 Repair And Disassembly: The disassembly feature was designed to allow users to easily disassemble the vent in one minute. 1). Remove the Plug. 2). Insert the T-Wrench into the nut of the Poppet. 3). Tighten the Lifting Nut. 4). Remove the Upper Housing. 5). Remove and replace the O Ring A4 www.girardequip.com Linden, NJ, 800.526.4330 Houston, TX, 281.532.1800 Chicago, IL 847.599.8566

3 DOT 407 Pressure Relief Vents FUNCTION Girard Equipment, Inc. s Three Inch DOT 407 Vents allows you to upgrade virtually any MC 307 or MC 312 tank to DOT 407 or DOT 412 venting. All the benefits of the 400 Series Vents without expensive hot-work. Flow rates are slightly less than our standard DOT 407 Vents, but are more than sufficient for most tanks. See the table below for specific flow rates. The stainless steel valve seat seals on a Teflon encapsulated silicone O Ring. This O Ring provides complete chemical resistance and a bubble-tight seal to meet the latest DOT requirements. The unit also meets the surge requirments of 178.345-10 (b) (3). STYLES 402018 Gasket 3TOR 402020 Gasket 3-CFE DESCRIPTION DOT3X407T Vent with a 3 N.P.S. female pipe thread. Attaches to a 3 pipe nipple and seals against a solid Teflon O Ring Gasket. DOT3X407F Vent to mount on a 3 TTMA flange. Supplied with a Teflon envelope flange gasket. REPLACEMENT PARTS The 3 T, F and AF Models are similiar in every detail with the only exception being the connection on the lower housing. When ordering replacement parts, please refer to the exploded view of the vent and order by: quantity, part number, and description (i.e., 6 each of part number 402006L Low Profile Poppet ). 402021 Gasket 402022 PERFORMANCE SPECIFICATIONS DOT3X407AF Vent to mount on a 3 ANSI flange. Supplied with a Teflon envelope flange gasket and a 1/4 NPT Tell- Tale indicator tap. MAWP Test Flow Exposed Pressure (SCFH) Surface 25 40 372,844 732 25 45 408,485 860 30 45 408,485 860 35 52.5 460,443 1061 MATERIALS OF CONSTRUCTION ORDERING INFORMATION All Vents are designated by the connection style and the Maximum Allowable Working Pressure (MAWP) of the tank that it will be attached to. Order Vents by style-pressure code. PRESSURE CODE: MAWP CODE 25 (none) 30 1 35 2 Other (Specify) 3 MAINTENANCE INFORMATION Repair manuals, as well as special tools, are available upon request. All metallic parts Stainless Steel O Ring Teflon encapsulated silicone Gasket Teflon www.girardequip.com Linden, NJ, 800.526.4330 Houston, TX, 281.532.1800 Chicago, IL 847.599.8566 A1

3 DOT 407 Pressure Relief Vents ITEMS PART NUMBER DESCRIPTION 1 1 402019 Plug 2 402003L Rain Cover 2 3 402004L Low Profile Upper Housing Specify MAWP 4 402005 Spring (for MAWP < 45 only) 402005HP Spring (for MAWP > 45 only) 5 402006LN Low Profile Poppet With Nut 6 402007 Teflon Silicone O Ring 3 7 402018 3 T Model Lower Housing 8 3TOR Solid Teflon O Ring Gasket 9 402020 3 F Model Lower Housing (TTMA) 10 3CFE Teflon Envelope Flange Gasket (TTMA) 11 402021 3 AF Model Lower Housing 5 6 4 12 402022 Teflon Envelope Flange Gasket (ANSI) 7 9 DOT 3X407AF (3 Ansi) Weight: 19 lbs. 8 11 10 8 12 DOT 3X407F (3 TTMA Flange) Weight: 15 lbs. 7 1 2 DOT 3X407T Weight: 11 lbs. Installed Height: 5 1 4 over the top of the pipe nipple 6 3 N.P.S Female Thread A2 www.girardequip.com Linden, NJ, 800.526.4330 Houston, TX, 281.532.1800 Chicago, IL 847.599.8566