Equipment Standard Operating Procedure Greg Allion and Kimberly Appel

Similar documents
University of Minnesota Nano Fabrication Center

University of Minnesota Nano Fabrication Center

Warnings: Notes: Revised: October 5, 2015

Standard Operating Manual

Karl Suss MA6 Mask Aligner SOP

Usage Policies Notebook for Karl Suss MA6 Mid / Deep UV Mask Aligner

MJB4 Mask Aligner Operating Procedure. Effective Date: 07/12/2012 Author(s): Jiong Hua Phone:

Karl Suss MJB4 Mask Aligner

Warnings: Notes: Revised: January 8,

KARL SUSS MJB3 UV400 Mask Aligner Standard Operating Procedure

Quintel Mask Aligner

KARL SUSS MJB3 MASK ALIGNER STANDARD OPERATING PROCEDURE

MJB-3 Mask Aligner Property of TAU MNCF August 2012

Karl Suss Contact Aligner Operation

COBILT CA-800 Mask Aligner Equipment Operation

Standard Operating Manual

Approved by Principal Investigator Date: Approved by Super User: Date:

ABM MASK ALIGNERS. NanoFab 26 March 2009 A Micro Machining & Nanofabrication Facility

SOP for Karl Suss MJB3 #1 Mask Aligner

Photolithography. Operating Instructions

Operation of the mask aligner MJB-55

OAI Model 200 Tabletop Mask Aligner Portland State University

Operation of the contact mask aligner Canon PPC 210 Projection Print Camera

March CS-1701F Reactive Ion Etcher

Approved by Principal Investigator Date: Approved by Super User: Date:

EE 432 Lab 3 PMOS source/drain lithography and diffusion

Standard Operating Procedure. For. PVD E-Beam

Thermo K-Alpha XPS Standard Operating Procedure

STS ICP-RIE. Scott Munro (2-4826,

OPERATION OF THE DIMPLER

R I T. Title: Amray 1830 SEM Semiconductor & Microsystems Fabrication Laboratory Revision: A Rev Date: 09/29/03 1 SCOPE 2 REFERENCE DOCUMENTS

Nanofabrication Facility: PECVD SOP Rev. 00, April 24

NRF Suss Delta 80 Spinner SOP Revision /14/2016 Page 1 of 11. Suss Delta 80 Spinner SOP

BASIC Z-STACK AND TIME SERIES SCAN ON THE ZEISS LIGHTSHEET Z. 1

Issue: H Title: CHA E-Beam Evaporator Page 1 of 7. Table of Contents

Operating Procedures for Metal Evaporator I

Nanofabrication Facility: ECR Etcher SOP Rev. 01b, March 06. Standard Operating Procedure for PlasmaQuest ECR II Etching

COMELEC C-30-S Parylene Coating System

SPUTTER STATION STANDARD OPERATING PROCEDURE

Superconducting Susceptometer (MPMS-5S) Quantum Design Room 296 (MPMS)

NORDSON MARCH PX-1000 PLASMA ASHER STANDARD OPERATING PROCEDURE Version: 1.0 July 2016

1.1 Equipment: substrate, wafer tweezers, metal targets 1.2 Personal Protective Equipment: nitrile gloves, safety glasses 1.

M3-LED. Operator s Manual. Operator s Manual MADE IN THE USA USA

Misaligned Folds Paper Feed Problems Double Feeds Won t Feed FLYER Won t Run iii

User Manual GRI- 1500Li

Scanning Electron Microscope JEOL JSM F

icreasepro Creaser Operators Manual

5.1.3 Mechanical Hazards Drive assemblies have sufficient power to cause injury. Keep hands, fingers, clothing and tools clear of moving parts.

University of Minnesota, MN Nano Center Standard Operating Procedure

Met One E-BAM Particulate Monitor

Login to ilab Kiosk. Revised 05/22/2018. Load your sample:

Standard Operating Manual

Plasma Asher: March PX-500 User guide (May-30, 2017)

Usage Policies Notebook for STS DRIE System

University of MN, Minnesota Nano Center Standard Operating Procedure

Napa Technology Trouble Shooting. For Premier & Premier PLUS Models

Oerlikon Sputtering Evaporator SOP

SSI Solaris 150 RTA Revision /27/2016 Page 1 of 9. SSI Solaris 150 RTA

Standard Operating Manual

Notes-PECVD: Chamber 1

CircuFlow Quick Setup Guide

Agilent 1290 Infinity Pump Head Maintenance

Product Information News

University of MN, Minnesota Nano Center Standard Operating Procedure

Revised: June 7, 2017

Unifilm Technology PVD-300 Sputter Deposition Operation Instructions

Basic ICP Operating Procedures

Standard Operating Manual

Unaxis ICP/RIE SOP Revision 8 09/30/16 Page 1 of 5. NRF Unaxis ICP/RIE Etch SOP

Standard Operating Manual

OXFORD PLASMALAB 80PLUS (CLOEY)

University of MN, Minnesota Nano Center Standard Operating Procedure

Standard Operating Procedure #COE-SOP-0001 Chemical Fume Hood Operation

2. USER INSTRUCTION. Table of contents: Pg.1/14 N:\FAP-2000: LWP

Xactix XeF2 OPERATION MANUAL

General remarks regarding ALS robot system:

GRAVITY PROBE-B GYRO HOUSING LITHOGRAPHY PROCESS

JETFIRST 150 RTA SYSTEM OPERATING MANUAL Version: 2 Feb 2012

QUORUM TECH 150RES THE FIRST AND THIRD WEEK WILL BE SET UP FOR CARBON COATING THE SECOND AND LAST WEEK WILL BE SET UP FOR GOLD COATING

OPERATOR S MANUAL ATP [ADAPTIVE TRAINING PISTOLS]

The MRL Furnaces USED FOR THIS MANUAL COVERS

O P E R ATING INSTRUCTIONS FOR MODEL SPR-45 Automatic Screen and Stencil Printer

CZ52 Detail Strip, Disassembly, and Assembly Instructions Lonestar Fabrication & Design

Southern Eagles Soaring

Sport Grouse PRO REMOTE CONTROL LAUNCHER INSTRUCTION MANUAL

GRI-1300/1350Li. User Manual

THERMAL EVAPORATION UNIT (for Al evaporation)

LEO 1525 FEG SEM Standard Operating Procedures Mar. 6, 2012 For additional assistance, please contact the facility manager.

Standard Operational Procedure for Capillary Electrophoresis

PRODUCT MANUAL Glass Touch RGB Controller 12V-24V

Section 3- Repair and Calibration Procedures

CLEANLINESS STANDARD NCPRE tool contamination classification

Arizona State University Center for Solid State Electronics Research Issue: E Title: Heat Pulse 610 Operating Procedure Page 1 of 7

MAINTENANCE PROCEDURE FOR X 650

Arizona State University Center for Solid State Electronic Research. Table of Contents. Issue: C Title: Oxford Plasmalab 80plus (Floey) Page 1 of 8

Operations Manual. Internal automatic Pressure control for orbital tube welding. By Exel Orbital Systems, Inc. Page

User Guide. Pall Laboratory Manifold. For laboratory use. Not for use in a manner other than indicated. Introduction. Regulatory References

Underwater Housing for Panasonic Lumix DMC-ZS60, DMC-TZ80

Cryo-Evaporator Operation

BUILT TO WIN PAINTBALL LOADER SPIRE III MANUAL

Transcription:

Date Created: May 3, 2004 Date Modified: June 1, 2005 MA6/BA6 Mask Aligner Equipment Standard Operating Procedure Greg Allion and Kimberly Appel 1. Purpose 1.1. Photolithography involves transferring a pattern from a mask to a wafer coated with photo resist. 1.2. MA6 has the capability of processing both top and backside alignment. 1.3. This tool is primarily used for high-resolution lithography (<2µm) and/or critical alignment tolerances (<1µm). 2. Reference Documents 2.1. Karl Suss MA6 User Manual 3. Equipment 3.1. Tweezers 3.2. N 2 gun 3.3. Vacuum wand 4. Materials 4.1. N/A 5. Protective Equipment 5.1. Eye Protection: safety glasses must be worn at all times. 5.2. Hand Protection: vinyl or latex-free gloves. 6. Engineering and/or Administrative Controls 6.1. The MA6 is located in the Sub micron Room. Page 1 of 8

6.2. The tool owner and check off person is Greg Allion, gallion@eecs.umich.edu. 6.3. Only authorized user may operate this piece of equipment. 6.4. This tool must be reserved in advance for use. Sign up sheets are located on the SSEL Scheduler. 6.4.1. If you sign up for a time slot and cannot make it, then be considerate and remove your name from the sheet. 7. Procedure 7.1. Tool Parameters 7.1.1. This tool shall only be used for feature sizes of 2 microns or less. 7.1.2. This tool shall only be used for lithography processes requiring critical dimensions or in the event that the 620 is not functioning. 7.2. Mercury Arc Lamp 7.2.1. The lamp operates in constant intensity mode. 7.2.1.1.As the lamp deteriorates, the power is automatically adjusted to keep the intensity of the wavelength. 7.2.1.2.The intensity of the lamp may be read from the power supply during exposure or during a lamp test. 7.2.2. Typical lamp uniformity is less than 2% over a 4-inch area. 7.3. Exposure Modes 7.3.1. Soft Contact: the substrate is brought into contact with the mask by a preset force during exposure, for features 2µm. 7.3.2. Hard Contact: this is the same as soft contact except that nitrogen gives added pressure upward towards the wafer, for features < 2µm. 7.3.3. Vacuum Contact: a vacuum seal inflates to form a chamber; the pre-vac time serves to allow the vacuum to proceed slowly. 7.3.3.1.For long exposures that may cause out gassing. 7.3.4. Proximity: a user defined distance separates the mask and wafer. The mask and wafer makes contact only during WEC unless spacers are used. 7.3.4.1.For delicate structures or substrates. 7.3.5. Flood Exposure: for first level exposure. Once the mask and wafer are loaded the aligner proceeds to expose skipping the alignment step. 7.4. Alignment Features 7.4.1. Top side: TSA, the top microscope is used to align mask features to the topside of the wafer. 7.4.2. Back side: BSA, the bottom objectives are used to align mask features to the back of the wafer. 7.4.2.1.This is achieved by aligning a captured image of the mask and the real image of the wafer. 7.4.3. Minimum feature size is around 0.8um. 7.5. WEC Types 7.5.1. WEC: wedge error compensation. 7.5.1.1.After loading the substrate WEC will occur. It is the procedure by which the chuck automatically adjusts such that the wafer is perfectly Page 2 of 8

parallel to the mask. While WEC is in process, avoid leaning on the table. 7.5.2. Prox WEC: three (3) proximity flags act as separators (spacers) between the wafer and mask. 7.6. Mask Clean 7.6.1. Ensure the mask is clean before using. 7.6.2. Use the mask clean bench to clean the mask. 7.6.2.1.Dip in Acetone/ IPA #1/ IPA #2 and N 2 dry. You may also use the Evergreen Mask cleaning station. 7.6.2.2.Any particles on the mask can be transferred to your wafer. 7.7. Photo Resist 7.7.1. Positive resist: Any resist exposed to ultra-violet light is developed away. 7.7.2. Negative resist: Resist remains on the surface where exposed. 7.8. Start Up On/off key 7.8.1. Turn on the system, if not already on. Use the on/off key. 7.8.2. If the TV monitor is not on then turn it on. 7.8.3. Ensure that Channel 2 is lit (lamp power supply). The lamp is 405nm (20 mw/cm 2 ) and 365nm (11mW/ cm 2) 7.8.4. Press load. 7.8.5. Ensure that the configuration is MA6 for lithography. 7.8.5.1.BA6 is for bonding alignment. 7.8.6. Press enter. 7.8.7. Ensure the micrometers setting is 10mm; this is the large knob on the right and left side of the system (X and Y stage micrometer). Page 3 of 8

7.8.8. Ensure that the theta (white line on front of system) is lined up. 7.8.9. Ensure that the N 2 line for the mask holder is connected. 7.9. Loading Mask 7.9.1. There are three different mask holder sizes, 4 inch, 5 inch and 7 inch. 7.9.1.1. 5-inch is the default mask holder. 7.9.2. Press the change mask key. 7.9.3. Slide the mask tray out, flip over and place on table to left of system. 7.9.3.1.Place the mask to be used on the holder (chrome side up). Use the three (3) alignment pins to center the mask. 7.9.3.2.The major flat of the mask should be facing towards you (If you designed a major flat on your mask). 7.9.3.3.Depress the enter key to turn the vacuum on. 7.9.3.4.Push the silver tab down on the spring-loaded clip to engage it towards the mask. 7.9.3.5.Use the nitrogen gun to remove any particle on the mask. 7.9.3.6.Flip the mask holder over, have your hand underneath to verify that the mask is on the tray. 7.9.3.7. Slide the tray back into place. 7.9.3.8.Press the change mask key. The mask tray should now be locked into place. 7.9.3.9.The ready to load message should appears on the display. 7.10. Edit Parameter Page 4 of 8

7.10.1. Press edit parameter key. 7.10.2. Press the x-lateral key to scroll through the parameters. You may choose the contact mode, exposure time, and alignment gap. 7.10.2.1. Use the Y- up/down key to change the desired parameter values. 7.10.2.2. Press the edit parameter key when finished. 7.11. Wafer Loading 7.11.1. There are a few wafer chucks to choose from. The 4-inch chuck is the default chuck. 7.11.1.1. The other chucks are kept in the cabinet. 7.11.1.2. Ensure that the vacuum grooves are completely covered by the wafer. 7.11.1.3. Ensure that the white line on the wafer chuck is in alignment. 7.11.2. Press the load key and slide the substrate holder straight out. The enter and unload light should be flashing. 7.11.3. Place the wafer on the chuck with the major flat facing you. 7.11.3.1. There should be no resist on the backside of the wafer. The resist could affect the flatness of the wafer. 7.11.3.2. The wafer should touch against the three (3) steel alignment pins on the holder. 7.11.4. Press the enter key to turn the vacuum on. 7.11.4.1. Gently nudge the side of the wafer to check vacuum. 7.11.5. Use the nitrogen gun to blow off any particles. 7.11.6. Slowly slide the wafer chuck back into the system. 7.11.7. Push enter. The WEC shall now be performed. Try not to lean on the table. 7.12. Top Side Alignment, (TSA) 7.12.1. Ensure illumination is set to TSA. Page 5 of 8

7.12.2. Press F1 and enter to lower the microscope. 7.12.3. Press BSA, so that the light goes off. You are now ready for top side alignment. 7.12.4. Key Top/Bottom, Focus knobs 7.12.4.1. Light on, top substrate focus is active. 7.12.4.1.1. A top substrate knob is used to focus on the mask. 7.12.4.2. Light off, bottom substrate focus is active. 7.12.4.3. Bottom substrate knob is used to focus on wafer. 7.12.5. Position the objectives over the mask alignment marks using the X-Y arrow keys. 7.12.5.1. The alignment marks are used to ensure each mask step fits on top of the previous step. If anything is mis-aligned you have the chance for devices to fail. 7.12.5.2. The distance between the left and right objectives may be adjusted by using the separation knobs. 7.12.5.2.1. The separation knob is located on the left and right side objectives. 7.12.5.3. Theta is the knob located at the front of the system. 7.12.6. You can select from three (3) different image options; split field, single field left and single field right. 7.12.6.1. Single field doubles the field of view on the screen, facilitating the search for alignment marks. 7.13. Alignment 7.13.1. Ensure system is in alignment mode; the alignment/cont key should be illuminated. 7.13.1.1. If you are in contact mode, you will see an orange light illuminated. 7.13.2. The three micrometers located on the wafer stage, adjusts the movement of the wafer. 7.13.3. If resistance is felt during adjustment of the wafer, press the separation key to increase the distance. 7.13.4. Alignment shift can occur between mask and wafer when in contact mode. To ensure proper alignment press the Alignment Check Key. 7.14. Exposure 7.14.1. Once satisfied with the ailment, press the exposure key. 7.14.1.1. The microscope head will move up out of the way and the exposure assembly will slide out. 7.14.1.1.1. During exposure, do not look at the ultra violet light; it can be harmful to your eyes over time. 7.14.2. After exposure the microscope will drop back into place and you are ready to unload your wafer. 7.14.3. Slide the wafer tray out and press the enter key to toggle off the vacuum. 7.14.4. Remove wafer and slide tray back in. 7.14.5. Press load for next wafer or mask change to retrieve mask and end process. Page 6 of 8

7.15. Bottom Side Alignment, BSA 7.15.1. The bottom side objectives are used to place a pattern on the backside of your wafer. 7.15.2. Insert the appropriate wafer chuck onto the slide (need the one with the windows). 7.15.3. Select BSA/IR key. 7.15.4. Depress the BSA Microscope key. 7.15.4.1. The X-Y keys can now move the bottom objectives. 7.15.5. Press the top/bottom key to focus the mask. 7.15.6. After locating the alignment marks on the mask, press the grab image key. 7.15.6.1. This will then capture the mask image. 7.15.7. Press the load key and slide out the wafer tray. 7.15.7.1. Load sample pattern side down (resist should be facing up). 7.15.8. Press the enter key to turn the vacuum on. 7.15.9. Slide the tray back in and the WEC should start. 7.15.10. Check that the Top/Bottom key is in bottom mode is illuminated. 7.15.11. Adjust bottom substrate focus to obtain a clear image. 7.15.12. Align wafer to image of mask. 7.15.13. Once satisfied with alignment, you are ready to expose. 7.16. Shut Down 7.16.1. When you have completed exposing all wafers, check that the wafer chuck is clean. 7.16.1.1. It should be free of particles and resist. 7.16.1.2. Slide tray back into system. 7.16.2. Press change mask. 7.16.2.1. Slide the mask tray out and place on shelf to left. 7.16.2.2. Release the spring clip 7.16.2.3. Press the enter key to turn off the vacuum. 7.16.2.4. Place the mask tray back into place. 7.16.3. Turn system off. 7.16.4. Leave the lamp and TV monitor on. 7.16.5. Leave system set up for 4 inch alignment. 7.16.6. Do NOT leave in flood exposure. 7.16.7. Complete the logbook. 7.17. Troubleshooting 7.17.1. Mask cannot be focused. 7.17.1.1. Mask loaded wrong; ensure the chrome side faces up. 7.17.2. Wafer can not focus 7.17.2.1. WEC was not done correctly, reload wafer. 7.17.2.2. Alignment gap is to large, adjust gap using separator key 7.17.3. Mask and wafer move at same time during alignment 7.17.3.1. Mask and wafer are touching, reload mask and wafer. 7.17.3.2. Mask might have lost vacuum, check mask vacuum. 8. Waste Products Page 7 of 8

8.1. Broken wafers are to be discarded in the glass trash. Report all accidents (injuries, spills, fires) to the SSEL On Call or other SSEL staff. For emergencies during non-business hours, call the SSEL Emergency Response Team at (734) 764-4127 or Department of Public Safety at (734) 763-1131. Page 8 of 8