Modular Venturi Vacuum Pumps with Solenoid-Operated Vacuum and Blow-Off Vaccon offers a High Vacuum Venturi Pump in a variety of performance ranges. Each HighVac Series Pump is capable of 29.5 Hg [999mbar] at sea level. HVP Series HighVac Pump The high vacuum level and compact size of the HVP pump allows you to incorporate smaller and more efficient components in your design. Often used to replace expensive, noisy, heat generating electric pumps, HVP pumps are quiet and maintenance free, ideal for small shops, labs and recharging HVAC systems. See Page... 5.2 HighVac Pumps Phone: 1-800-848-8788 or 508-359-7200 E-Mail: engineering@vaccon.com 5.1
High Vacuum Venturi Pump up to 29.5 Hg [999mbar] with Silencer HighVac Series: HVP-100, 200, 300 HVP-100 degassing viscous liquids such as silicone and other mold compounds Ideal Applications: Process control Vessel evacuation HVAC applications Degassing Features/Benefits: High performance powerful vacuum up to 29.5 Hg [999mbar] Fast response time no delay due to long plumbing lines; mounts in-line and installs close to vacuum point Efficient - minimal air consumption Compact, lightweight and modular easy to install Safe operation no electricity needed at the pump Reliable, trouble-free operation: ~ No moving parts to wear ~ No flap valves to stick open ~ No maintenance ~ No downtime Standard Pump: The HighVac Series of air-powered venturi vacuum pumps generate vacuum levels up to 29.5 Hg [999mbar] and offer three vacuum flow rates. The high vacuum level and compact size of the HVP pump allows you to incorporate smaller and more efficient components in your design. Often used to replace expensive, noisy, heat generating electric pumps, HVP pumps are quiet and maintenance free, ideal for small shops, labs and recharging HVAC systems. HVP Series Pump Options: Factory-installed miniature electronic sensors or switches to provide signal for vacuum achieved, part present. Will interface with PLC s and computerized control systems. Factory-installed vacuum gauge Principles of Operation: Vacuum is produced by forcing compressed air through a limiting orifice (nozzle), where after exiting, it expands, increasing to supersonic speed before entering the diffuser. Vacuum is created at the vacuum inlet port, between the nozzle and diffuser. The combined nozzle and diffuser create a venturi vacuum cartridge. In the HVP venturi pump, there are 2 venturi cartridges. The exhaust from the vertical cartridge is directed into the vacuum port of the second horizontal venturi cartridge. The flow from the vertical cartridge in effect supercharges the second cartridge producing high vacuum level, up to 29.5 Hg [999mbar]. Air Supply Vacuum Exhaust Eliminate the Guesswork: Contact Us! Vacuum technology isn t an exact science. To ensure proper product selection, Vaccon offers free application engineering assistance, a 30 Day Test & Evaluation Program or you can send sample products to our in-house test facility and we will test and size a pump for you. To download a complete set of drawings in multiple CAD formats, please visit our website at www.vaccon.com For more information or technical assistance, please call 508-359-7200 or 800-848-8788 or email engineering@vaccon.com 5.2 Phone: 1-800-848-8788 or 508-359-7200 E-Mail: engineering@vaccon.com
HVP HighVac Series Configurations and Options: Drawing below is representative of all HVP pumps. Switches/Sensor - (Factory Installed Option - all w/ Quick Disconnect) VSMN-QD-6 6 pigtail & QD VSMP-QD-6 6 pigtail & QD VTMV-QD-6 6 pigtail & QD EP - Extra Port (optional) for Switch/Sensor VG-150-CBM Vacuum Gauge (Factory Installed Option) GP - Gauge Port (optional) for Vacuum Gauge How to Specify: I-HVP-100 - EP - VSMN-QD-6 - GP - VG-150-CBM HVP-100 HVP-200 HVP-300 I-HVP-100 I-HVP-200 I-HVP-300 Imperial Thread NPT NPT NPT Metric Thread G Port G Port G Port Vacuum Gauge VG-150-CBM Center Back Mount Note: Vaccon does not ship gauges attached to pumps to avoid damage during shipping. Gauges are easily screwed into gauge port at the time of installation. GP Gauge Port Gauge Port (Optional) for Vacuum Gauge Switch/Sensor None (Standard) VSMN-QD-6 Switch NPN with QD VSMP-QD-6 Switch PNP with QD VTMV-QD-6 Sensor 1-5VDC Output w/qd EP Extra Port Extra Port (Optional) for Switch/ Sensor Please note: Vacuum Level = The magnitude of suction created by the vacuum pump. Vacuum level is affected by elevation and barometric pressure. For each 1,000 feet of elevation, the vacuum level that the pump can achieve decreases by approximately 1 Hg [33.9mbar]. Phone: 1-800-848-8788 or 508-359-7200 E-Mail: engineering@vaccon.com 5.3
HVP HighVac Series Configurations and Options: Drawing below is representative of all HVP pumps. J P 'B' VACUUM PORT HIGHVAC H V P S E R I E S 2 0 0 U H F E 'A' AIR SUPPLY PORT L K A I R S U P P L Y M N V A C C O N V A C U U M V A C U U M P U M P A I R F L O W M E D F I E L D, M A 8 0 0-8 4 8-8 7 8 8 R ST-8A 'C' EXHAUST PORT VACCON MEDFIELD, MA 800-848-8788 A I R F L O W ST SERIES SILENCER S T - 8 A 3X Ø 'D' MOUNTING HOLES Ø S E T F On-line Configurator and CAD Drawings @ www.vaccon.com New powerful design tool saves you time by configuring the pump you need on-line. When complete, simply download the CAD drawing in any one of 13 different CAD formats and insert it right into your design. Get the pump you need, in the format you like! V HVP-100 HVP-200 HVP-300 Specifications: Weight: Noise Level: 9oz [255g] 71 db Specifications: Weight: Noise Level: 1 lb 11 oz [765g] 74 db Specifications: Weight: Noise Level: 2 lb [907g] 79 db Imperial Dimensions (in.) A B C D E F H J K L M N P R S T U V HVP-100 1/4 NPTF 1/8 NPTF 1/4 NPTF 0.12 0.38 0.38 2.28 0.75 0.09 0.67 1.78 N/A 3.20 5.06 0.75 1.28 3.02 2.00 HVP-200 1/4 NPTF 1/4 NPTF 1/2 NPTF 0.21 0.50 0.75 4.02 1.00 0.20 N/A 2.20 3.70 4.00 7.57 1.00 2.13 4.76 2.00 HVP-300 3/8 NPTF 1/4 NPTF 1/2 NPTF 0.21 0.50 0.75 4.02 1.00 0.20 N/A 2.50 4.00 5.00 9.81 1.25 2.12 4.76 2.00 Metric Dimensions (mm) A B C D E F H J K L M N P R S T U U I-HVP-100 G 1/4 G 1/8 G 1/4 3.1 9.7 9.7 57.9 19.1 2.3 17.0 45.2 N/A 81.3 128.5 19.1 32.5 76.7 50.8 I-HVP-200 G 1/4 G 1/4 G 1/2 5.3 12.7 19.1 102.1 25.4 5.1 N/A 55.9 94.0 101.6 192.3 25.4 54.1 120.9 50.8 I-HVP-300 G 3/8 G 1/4 G 1/2 5.3 12.7 19.1 102.1 25.4 5.1 N/A 63.5 101.6 127.0 249.2 31.8 53.8 120.9 50.8 5.4 Phone: 1-800-848-8788 or 508-359-7200 E-Mail: engineering@vaccon.com
HVP Pump Standard Specifications: Pump Material: Anodized Aluminum (For silencer material, see Silencer section see page 13.5) Cartridge Material: Aluminum, Brass, Buna-N (Other materials available, see page 1.6) Medium: Operating Temperature: Operating Pressure: Filtered (50 Micron) unlubricated, noncorrosive dry gases -30 to ~250 F [-34 to ~121 C] 80 PSI [5.5 bar] standard or (HVP-100 only) 60 PSI [4.1 bar] Consult Factory for other operating pressures HVP Pump Installation Requirements: Vacuum Line & Supply Line HVP-100/200: 3/8 O.D. [10mm] tube recommended Vacuum Line Filtration HVP-100/200: Typically filters are not required; if desired Vaccon recommends VF250. See page 13.12 Vacuum Line & Supply Line HVP-300: 1/2 O.D. [12mm] tube recommended Vacuum Line Filtration HVP-300: Typically filters are not required; if desired Vaccon recommends VF375. See page 13.12 Mounting Holes: HVP-100 = 4-40 [M3], HVP-200/300 = #10-32 [M5] screws Air Consumption SCFM HVP Series - Performance Data Imperial Vacuum Flow (SCFM) vs. Vacuum Level ( Hg) O Hg 3 Hg 6 Hg 9 Hg 12 Hg 15 Hg 18 Hg 21 Hg 24 Hg 27 Hg 29.5 Hg HVP-100 4.90 1.30 1.20 1.10 1.00 0.90 0.90 0.90 0.80 0.60 0.30 0.00 HVP-200 8.60 3.45 3.25 3.05 2.75 2.45 2.05 1.90 1.60 1.30 0.90 0.00 HVP-300 22.00 6.00 5.10 4.70 4.40 4.10 3.60 3.00 2.60 1.80 0.90 0.00 Evacuation Time in Seconds based on 1 Cubic Foot Volume/ Hg O Hg 3 Hg 6 Hg 9 Hg 12 Hg 15 Hg 18 Hg 21 Hg 24 Hg 27 Hg 29.5 Hg HVP-100 0.00 6.50 12.30 18.90 32.50 40.00 52.50 72.50 98.00 135.50 281.30 HVP-200 0.00 2.30 3.80 6.50 10.20 14.10 20.00 29.50 44.00 67.50 125.00 HVP-300 0.00 1.20 2.10 3.40 5.20 7.70 11.50 16.30 24.00 39.50 98.10 Note 1: Standard operating pressure for Vaccon pumps is 80 PSI [5.5 bar]. The HVP-100 can be factory modified to run at other operating pressures i.e. 60 PSI [4.1 bar] etc. The values shown in the performance chart will remain the same for all operating pressures. Note 2: Evacuation speed is linear with volume. A 2 cu. ft. volume will take twice as long to evacuate as a 1 cu. ft. volume. Air Consumption L/min Metric Vacuum Flow (L/min) vs. Vacuum Level (mbar) O mbar 102 mbar 203 mbar 305 mbar 406 mbar 508mbar 609 mbar 711 mbar 813 mbar 914 mbar 999 mbar I-HVP-100 138.8 36.8 34.0 31.1 28.3 25.5 25.5 25.5 22.7 17.0 8.5 0.0 I-HVP-200 243.5 97.7 92.0 86.4 77.9 69.4 58.0 53.8 45.3 36.8 25.5 0.0 I-HVP-300 623.0 169.9 144.4 133.1 124.6 116.1 101.9 85.0 73.6 51.0 25.5 0.0 Evacuation Time in Seconds based on 1 Liter Volume/mbar O mbar 102 mbar 203 mbar 305 mbar 339 mbar 508mbar 609 mbar 711 mbar 813 mbar 914 mbar 999 mbar I-HVP-100 0.00 0.2 0.4 0.7 1.1 1.4 1.9 2.6 3.5 4.8 9.9 I-HVP-200 0.00 0.1 0.1 0.2 0.4 0.5 0.7 1.0 1.6 2.4 4.4 I-HVP-300 0.00 0.0 0.1 0.1 0.2 0.3 0.4 0.6 0.8 1.4 3.5 Note 1: Standard operating pressure for Vaccon pumps is 80 PSI [5.5 bar]. The HVP-100 can be factory modified to run at other operating pressures i.e. 60 PSI [4.1 bar] etc. The values shown in the performance chart will remain the same for all operating pressures. Note 2: Evacuation speed is linear with volume. A 2 cu. ft. volume will take twice as long to evacuate as a 1 cu. ft. volume. Note: Performance Charts represent average performance data. For reference only. Phone: 1-800-848-8788 or 508-359-7200 E-Mail: engineering@vaccon.com 5.5
NOTES: 5.6 Phone: 1-800-848-8788 or 508-359-7200 E-Mail: engineering@vaccon.com