DTG - LCD Digital Temperature Gauge USER MANUAL

Similar documents
Electronic gas volume corrector model DGVC-04

How to specify a product. Process Sensors and Mechanical Instruments

E8AA. Pressure Sensor of Stainless Steel Construction Is Ideal for a Wide Range of Applications. Pressure Sensor (Stainless Steel Diaphragm)

Pro-V Multivariable Flowmeter

Operation manual Level sensor DC-LS-50 Operation Manual Level Sensor DC-LS-50

Precision pressure sensor Basic version Model CPT6020

IDL01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05

GILMONT ACCUCAL FLOWMETERS

DM01. Please visit our website: Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

Expert Hydrostatic Level Transmitters

SITRANS P measuring instruments for pressure

ETd 04. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. Type: ETd 04. class 0.05

Differential Pressure Transmiter

analytical bulk flow distance FLOW level pressure temperature industrial communication

ThermoVault Max. Extreme Temperature Thermal Barrier. Product User Guide

Features. Description

780S Ultra High Purity Series

Thermo Probe, Inc. TP-5 TP-7 TP-8. Instruction Manual English. Switch. Display. Carry Strap. Probe. Ground Clip. Switch. Display.

Installation and Operation Manual

DM01. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

2 Overview. SITRANS P measuring instruments for pressure. Transmitters for gage and absolute pressure. Z series for gage pressure

L (up to 25 m) Electronic part. working temp.: Ñ IP 66 / IP67. Mounting bracket ÐÑ. Sensor type. working temp.:

RTD Temperature sensor TH11

INSTRUCTION MANUAL MP4AR Remote Convection Gauge Range: 1 x 10-3 Torr to 1 x 10+3 Torr

Handi+ OPERATING MANUAL & INSTRUCTIONS FOR USE. R218P15 Industrial. R218M15 Rev. D

Pressure Measurement. Transmitters for basic requirements SITRANS P Z for gauge pressure. 2/4 Siemens FI Overview

TH-1800-T TRX-700-CNG Converter

INSTALLATION & MAINTENANCE INSTRUCTIONS

NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE

Precision Liquid Settlement Array Manual

KMT. Thermal Mass Flow Meter. for Compressed Air and Gases. Measuring range: m3n/h m3 N

MASS-STREAM TM Instruction Manual. D-6200 Analog Mass Flow Meters / Controllers

EASIDEW TRANSMITTER with Current Source Output

Installation, operating and maintenance Instructions for Seemag bypass level indicator

L3 Pressure and Level transmitter

QBS Electronic Pressure Regulator

INSTALLATION & MAINTENANCE INSTRUCTIONS DESCRIPTION SPECIFICATIONS. CE (EMC) Compliant

HAYWARD FLOW CONTROL TFS SERIES FLOW METER INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

COMPAFLOW. Compressed Air. Volumetric flow. Gas. Mass flow. Steam. Net volumetric flow. Liquid

EC214 EC215 - EC215R Bench Conductivity Meters

HI 2314 HI 2315 HI 23151

Type 1367 High-Pressure Instrument Supply System with Overpressure Protection

PanaFlow MV82. Insertion Style Multivariable Flowmeter. GE Measurement & Control. Key Benefits. Applications

3.0 Pressure Transmitter Selection

DeltaSpan Pressure Transmitters LD10 Series Owner s Manual

High-performance submersible pressure transmitter For level measurement Model LH-10

INSTALLATION, OPERATION AND MAINTENANCE GUIDE

Expansion Thermometers Stainless Steel Series, Model 70

Flow and Energy Measurement F-5400 THERMAL MASS FLOW METER

PURA. Pure Gas Dewpoint Transmitter. Users Guide

L 100. Bubble-Tube Level System. Installation, Operation and Maintenance Instructions

BAPI Pressure Line of Products - FAQs

Optical Dissolved Oxygen Meter

Hand-held pressure calibrator with integrated pump Model CPH6600

SCAM T.P.E. WATER TREATMENT SYSTEM SWT- AP AUTOMATIC PURGE

User Manual Pressure Calibration System C and Hydraulic Pressure Pump Models T-620/T-620H Copyright 2008 AMETEK Denmark A/S

GI Series Diaphragm Pressure Gauge Guard

PM105 PRESSURE METER USER S MANUAL

OC Panel High Limit Aquastat Kit, Manual Reset p/n

BS12N Piezoresistive OEM Pressure Sensor

SDS -Series 4C-D201/-D202 Supplemental Drying System User s Manual

RTX 1000H Series. Versatile Transmitters for a World of Pressure. GE Measurement & Control. Features

TANK MANAGER FOR TWO TANKS OPERATING MANUAL. 10/31/11 C-More T6C L color touch panel

T EK-SUB 4800C 19 mm Submersible Level Transmitter

BS12 Piezoresistive OEM Pressure Sensor

LVU2800 Series. Ultrasonic Level Transmitter

User's Manual. Heavy Duty Dissolved Oxygen Meter. Model

BAROMETER PRESSURE STANDARD PRESSURE CONTROLLER

Sanitary RTD Temperature sensor TH17. Measuring System Sanitary RTD assembly with connection head TH17 for food and dairy applications.

GAS FUEL VALVE FORM AGV5 OM 8-03

Kube Engineering Quinn E. Eddins, B.S.E.E Phone

Installation, Operation, & Maintenance Manual. MODEL: Watlow Controller P53 Direct, P53 Remote

HAYWARD FLOW CONTROL Series PBV Back Pressure Valve and Series RPV Pressure Relief Valve INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS

P499 Heavy Duty Pressure Transducer

Type N-10, N-11 Hazardous Area Non-incendive Transmitters

DPC-30 DPC-100. Reference Manual

HBLT-A1 LIQUID LEVEL SENSOR

Pro-V Multivariable Flowmeter Model M22 In-line Vortex

Optical Dissolved Oxygen Meter

Heavy Duty Dissolved Oxygen Meter

3 GALLON, OILLESS PANCAKE COMPRESSOR INSTRUCTIONS. Item #31289

Section 3- Repair and Calibration Procedures

Your safety and the safety of others are very important.

Bante810 Benchtop Dissolved Oxygen Meter Instruction Manual

Deep Submersible Level Transducer Series 300DS

RCD - Ultra-Rugged Differential Pressure Flowmeter

Rosemount 400 and 400VP

Operating Instructions DB41

UNIK 5600/5700 Marine Certified Pressure Sensing Platform

Bristol Thermometer Systems Class 1 - Liquid Filled

AMS 2710 PCB pressure sensor module with V output

BGA244 Binary Gas Analyzer

For Multi-Parameter Meters see mvx

Columbus Instruments

A28 Series Two-Stage Temperature Controls with NEMA 1 Enclosure

Media-Isolated Mag Plus Probe Low Pressure-ISO Kit

SITRANS. Pressure transmitter SITRANS P, Z series for gauge and absolute pressure. Introduction. Safety instructions 2.

KTE6000 / KTU6000 Series OEM pressure transmitters for industrial media

Autocalibration Systems For In Situ Oxygen Analyzers

200A Series ELECTRONIC LEVEL TRANSMITTER

Transcription:

DTG - LCD USER MANUAL Page 1 of 7

USERS GUIDE page 1. Description 3 2. Function 3 3. Safety Instruction 3 3.1. Safety Conventions 3 3.2. Proper Use 3 4. Installation 4 4.1. Unpacking 4 4.2. Storage 4 4.3. Orientation 4 4.4. Troubleshooting 4 5. Limits 5 5.1. Pressure Limits 5 5.2. Temperature Limits 5 5.3. Thermal Characteristics 5 5.4. Response Time 5 6. Calibration 5 7. Long Term Stability 5 8. Error Codes 5 9. Dimensions 6 10. Technical Specifications 7 Page 2 of 7

1. Description The DTG series Digital Temperature Gauges are a complete solution for most industrial temperature monitoring and temperature indicating applications. Of high quality construction, these gauges features a large 4-digit LCD display. They are designed for optimum accuracy and performance. The series DTG are an ideal replacement for bi-metal, liquid bulb and gas thermometers. They are also a suitable replacement for Mercury reduction programs. The DTG arrives factory calibrated to the customer s specified temperature range. No costly field calibration is required. Housing, probe and fitting material is all fabricated from stainless steel 316. The DTG is rated to NEMA 4X ( IP65). Many mounting configurations are available to meet customer requirements. The DTG has a five year battery life with a low battery indication on the LCD. 3. Safety Instruction Read the instruction manual completely before installing the DTG temperature sensor. All safety guidelines should be followed and the sensor should only be installed by qualified personel following all local codes and regulations. 3.1. Safety Conventions The following symbols should be noted in this instruction manual. Attention: this symbol indicates an instruction that if not followed properly could lead to injury or death. Note: this symbol indicates an action that could lead to damage or contamination if not followed. 3.2. Proper Use 3.2.1. Designated use: These devices are intended for specific industrial applications. Appropriate fittings, materials and form must be chosen depending on the use. Proper specification must be done to conform with temperature, pressure and flow velocity requirements. 3.2.2. Installation: these devices must be installed by qualified personel taking all necessary precautions. The installation should adhere to all local regulations. 2. Function The DTG line of thermometers uses a Pt1000 Platinum RTD sensor which is read by our embedded processor and displayed on the LCD display. The LCD based DTG is battery powered and needs no wiring unless there are options chosen that require it. 3.2.3. Ensure that the label on the DTG is correct and that the model is appropriate for the particular application. 3.2.4. These devices are repairable. In the event of failure they should be returned to the factory for repair and recalibration. Please ensure the unit is clean and has no contaminants before returning. 3.2.5. If the installation will occur in a hazardous location or near hazardous materials all necessary precautions should be taken. 3.2.6. Mounting locations should be chosen to avoid high voltage electrical lines and for ease of installation and future maintenance. Page 3 of 7

4. Installation 4.1. Unpacking If there is any visible damage to the unit check the packaging and notify the shipper immediately. Included in the package should be one DTG and one instruction manual. 4.2. Storage: note that the device should be stored at a temperature between -20ºC to +70ºC (-4ºF to 160ºF) in a location that is reasonably dry and clean. 4.3. Orientation: see figure 1. There are no restrictions on the orientation of the probe installation location, but if there is a requirement for the pipe to be self draining the seating should be angled such that it will drain properly. The probe should be centered in the process flow no matter what the orientation. Angled inserts should have the probe pointing into the direction of flow as shown. Figure 1 Ensure that during installation all necessary precautions are taken. If this is a sanitary installation ensure that the probe has been properly cleaned in advance of installation and ensure that it is transported to the site of installation in a way that will maintain it s sanitary condition. If there are flammable or explosive fluids or gasses present at the site of installation ensure that proper grounding procedures are taken. Unwrapping a probe from bubble wrap or other packaging can impart a static charge on the probe which may discharge upon insertion into the mounting location. If the function demands it, seal the process connection with Teflon tape. Note: NPT connections should be hand tightened and then turned only 1-1/2 turns further with an appropriate wrench. This value may change according to what type of sealant is used on the pipe threads. Do not use the display body to tighten the probe into the mounting location. Doing so may damage the probe. Use only the process connection or compression fitting for tightening. 4.4. Troubleshooting If the unit fails to function properly there are no user serviceable parts inside. If returning the unit to Intempco please ensure that the unit is clean and free from any contaminants before shipping. 5. Wiring Note that the LCD based DTG is a battery powered device and needs no wiring unless it has been ordered with an option that requires wiring. Page 4 of 7

5. Limits 5.1. Pressure Limits The pressure limits for the probe is 500 psig, but the pressure limits for the process connection could be considerably less. Ensure the appropriate process connection is used for the desired pressure limits. 5.2. Temperature Limits The ambient temperature range for the exterior housing enclosing the processor should not exceed 0ºC to 50ºC (32ºF to 120ºF). The temperature limits for the probe should conform to the following table according to the unit ordered. 5.3. Thermal Characteristics For some RTD temperature indicators there is self heating from the measurement current. With Intempco DTG products the self heating is negligible. Any self heating error will be compensated for during factory calibration. Calibration of all Intempco DTG products takes place after the RTD, probe and electronics are assembled and immersed up to the process connection or a minimum of 10X the probe diameter. There should be no discrepancy in the measurement due to the thermal characteristics of the probe or process fitting. 5.4. Response Time BOX1 CODE CL FL Temperature Range Low Temp., display ºC -50 to 200ºC Low Temp., display ºF -58/392ºF Warm up is approximately 30 seconds, then response time is typically 3 seconds due to the display refresh rate. 6. Calibration Calibration is performed at the factory. For recalibration return the unit to the factory. Please ensure that the unit is clean and free of contaminants before shipping. On site calibration may only be conducted by an Intempco authorized representative or by factory trained professionals. Note that the temperature will affect the pressure and flow velocity limits of the probe. 7. Long-Term Stability The electronics and RTD should not deviate more than 0.05% per year if sized and installed properly. Regularly scheduled verification should be done to ensure that the unit is within accepted norms. Page 5 of 7 8. Error Codes The DTG is programmed to display the following error conditions. Err1 Shorted RTD condition Err2 Open RTD condition Err3 General Error LO Valid reading, but out of display range low Hi Valid reading, but out of display range hi batt Battery voltage is low - return to factory for battery replacement and recalibration.

9. Dimensions & Mounting Options DTG53 1.86 (47mm) DTG54 3.19 (81mm) 3.10 (79mm) Compression fitting x L Fixed fitting 0.7 (18mm) 1.75 (45mm) A D D NPT x 1/8 1.23 (31) 1/4 1.50 (38) 3/8 1.50 (38) 1/2 1.76 (45) 3/4 1.82 (46) Page 6 of 7

10. TECHNICAL SPECIFICATIONS Sensing Element : Measuring Temperature Ranges : Accuracy : Refresh Rate : Display : RTD, Type Pt1000 Ohm, Class A 50ºC to 200ºC ( 58ºC to 392ºF) or 200ºC to 600ºC ( 328ºF to 1112ºF) depending model. ±(0.2 + 0.002 x T ) ºC, factory, ±(0.36 + 0.002 x T-32 ) ºF, factory, ±(0.2 + 0.001 x T ) ºC, option, ±(0.36 + 0.001 x T-32 ) ºF, option 3 seconds Display Resolution : See table 1 Display Error Messages : RFI effect : 4-digit LCD, 1/2 high ( 12.7mm), decimal point selectable by software See operational manual 1% or less typical Temp. Effect : <0.01% FS/ ºC Ambient Temp. Range : Storage Temp. Range : Max. Pressure : 0ºC to 50ºC (32ºF to 122ºF) -20ºC to 70ºC (-4ºF to 158ºF) 500 PSIG (on probe) Housing Material : Stainless steel 316 Probe Material : Cable Materials : Weight : Environmental Protection : Power : Battery Life : Electrical Connection : Stainless steel 316 standard PVC, Teflon, Silicone, SS armored Teflon (with RTD output only) 350 grams (12 ounces) NEMA 4X/IP67 2 x 3.6 V AA Cells 5 years min. in continous mode ( low power battery indication) Micro-DC male plug or cable only (with RTD output only) RTD Output Option: RTD, Type Pt100 or Pt1000 Ohm, 2,3,4-wire, Class A DIN IEC 60715 Communication Option: Shipping Volume : Table 1: Display Resolution Communication option allows qualified users to calibrate, change measuring units and resolution. DTGLCD-PKIT required, order separately. Imperial Volume = 3.5 W X 3 H X (4.7 + L of probe) Metric Volume = 9.0cm W X 8cm H X (12cm + Lcm of probe) Model Range -50ºC to 200ºC (-58ºF to 392ºF) Factory Settings Optional Settings Setting Viewable Range Setting Viewable Range Setting Viewable Range 0.1-58.0 to 392.0 0.01-58.00 to 99.99 1-58 to 392-200ºC to 600ºC 1-328 to 1112 0.01-99.99 to 99.99 1-200 to 600 (-328ºF to 1112ºF) Teflon is a registered trademark of E.I. du Pont de Nemours and Company. Installation Considerations Installation requirements of the DTG are similar to those of the temperature sensor assemblies with head mounted hockey puck transmitter and display. If the temperature of the electronics in the housing exceeds 80 ºC, permanent damage to the DTG will occur. In all applications, careful attention must be placed on correct installation. For these applications, a remote probe wall mount unit or remote probe panel mount unit, may be a better choice. It is the installer s, customer s and/or end user s responsibility to make sure that this over exposure to temperature does not occur due to improper installation. Page 7 of 7