FIBERGLASS MANHOLES SANITARY SEWER LINES

Similar documents
VACUUM TESTING PRECAST CONCRETE MANHOLES

EVALUATION SUBJECT: DIVISION: HEATING, VENTILATING AND AIR CONDITIONING (HVAC) SECTION: HVAC DUCTS AND CASINGS.

22. Specialty Valves.

Glass Steel, Inc. Fiberglass Composite Troughs

Flowtite GRP manholes Installation Manual

MoBiLe CrAnes. surelift. B y W i r e r o p e i n d u s t r i e s. tower CrAnes. port CrAnes


CLEANING, INSPECTION, AND TESTING OF SEWERS

SPECIFICATION FOR THE INSTALLATION OF CURED IN PLACE RESIN SLEEVE FROM MANHOLE TO MANHOLE. (TOWN LINER)

SECTION BUTTERFLY VALVES

INSTALLATION, OPERATION AND MAINTENANCE MANUAL. Model Sanitary Vent SECTION I

Hynds Manhole System. Technical Guide D4.1

Installation, operation & maintenance manual - original version

Casing Spacer Technology Leaders

EVALUATION SUBJECT: SPUNSTRAND STANDARD AND INSULATED UNDERSLAB DUCTS

Simplicity in VRU by using a Beam Gas Compressor

SECTION ACCEPTANCE TESTING FOR SANITARY SEWERS

SUMMITTM 400 & 600. Natural Gas Barbecues. Step-By-Step Guide

Team Insert Valve Sample Specification The Insert Valve shall conform to the following:

VESSELS. Euro Pressure. Stainless Steel & Alloy Pressure Vessels

Safe-T-Span High Load Capacity Grating

Section GATE VALVES

Related Elevator Products

Homestead Series 820 AWWA Butterfly Valves

AWWA C504 COMPLIANT VALVES FROM 3 THRU 108

Agpro. Flush Valves TECHNICAL DATA / SPECIFICATIONS / APPLICATION GUIDE

Instruction Manual. Model TC1-S TopSide Clamp. top side clamp. For your personal safety READ and UNDERSTAND instructions before using tools.

Handling procedure for Scrubbers and Tanks made of thermoplastics.

BUTTERFLY VALVES Series 800

TIGHTNESS. Glass sealing Thanks to our glass-sealing technology, ODU products can meet the most demanding tightness requirements.

A hose layline contains important information for specifying the replacement assembly: manufacturer, hose trade name, working pressure and hose ID.

GRP Manholes and Chambers. for Gravity and Pressure Applications

Siting and Installation Manual

SPWE Series. Setup Instructions. Version 2.0

upvc MANHOLES APPLICATIONS Sewerage applications: Vacuum sewerage applications: Landfill applications: Valve boxes:

Serie 06-M6. Swing wafer check valve. made in. Application fields. Check valves E U R O P E WATER CONDITIONING INDUSTRY

Unit 1, Fullerton Road Rotherham S60 1DJ. Tele: Fax:

Food Service Industry Hose

Corrugated Steel Water Tanks Durable Water Storage

Material Handling Hose

Banyan Air Service November 18, 2011 AVE Aviation and Commerce Center Building 1 Miami, FL

DEH Instructions. Three-Phase, Platform-Mounted Distribution Transformers

94060 FRP Conservation Vent. Features. FRP Conservation Vent. One piece construction prevents product leakage

94060 FRP Conservation Vent. Features. FRP Conservation Vent. One piece construction prevents product leakage

Aquashield to Mitigate Water Ingress of Gas Pipes

IMPORTANT: RECEIVING INSTRUCTIONS:

TITAN FLOW CONTROL, INC.

FP McCann Tunnels and Shafts 1

9408 Series Dissolved Oxygen Systems. Dissolved oxygen systems designed for reliable operation with minimal operating costs

WAVE CYBER HANDLING &

VTL VFL VCL. Low Profile Series V RIGGING & ASSEMBLY INSTRUCTIONS

1.3 LIMITATIONS: The following application limitations must be recognized and considered before using this product:

Instruction Manual. PE Pipe Squeeze-off Tool Model TR650

INSTALLATION, OPERATION AND MAINTENANCE GUIDE

Tank Blanketing Pressure Regulators RHPS Series

Instrument Operating Manual

AV-202 Multigrout Technical Manual Page 1 DRINKING WATER SYSTEM COMPONENT ANSI/NSF 61 88NN

Now with. Covers. Grade Level Box BULK FEATURES TESTING CRITERIA TECHNICAL SPECIFICATIONS

In Ground Buried Uplights

Biodec Decanter. Ideal with our CYCLATOR technology

Design Data 22M. Flotation of Circular Concrete Pipe. w w I = w - x 1000 (3) (SG x 1000)

Model Copyright 2012 by General Machine Products (KT), LLC

GUIDELINES FOR CONDUCTING HYDROGENATION REACTIONS

Electrical Tapes Selection Guide. 3Innovation

HCMTCB MATERIALS SAMPLING & TESTING PERFORMANCE CHECKLIST

Saving When Repaving:

OWNER S MANUAL. This manual contains; IMPORTANT SAFETY INFORMATION INSTALLATION INSTRUCTIONS MAINTENANCE FACTORY SERVICE REPAIR PARTS WARRANTY

KlassikDrain Section. Technical Handbook and Product Catalog. General purpose trench drainage

MSC Guidelines for Independent Fuel Tanks

tunnels & shafts brochure

Operation and Maintenance Manual. First Defense and First Defense High Capacity. Vortex Separator for Stormwater Treatment

TWISTER Low Speed Surface Aerator

Typical Strength of Glued Connection. Typical Strength of Screwed Connection

Fair Winds Boat Repairs, LLC Riberia St. #7 St. Augustine, Fl

STYLE 3414/3416 & 3421/3423 Apollo Monitor with Foldaway Legs OPERATING & MAINTENANCE INSTRUCTIONS

Flygt low speed mixers

Product Manual B-Safety ClassicLine & PremiumLine Emergency Eyewash and Eye/Face Wash Equipment

Continental Industries TRANSITION FITTINGS or FAX Visit

Rail Track. Deck. Figure 3.9 Standard Fitting and Accessories for Single Deck Roof

product use, care, & inspection Document Released: January, 10, 2012 Approved By: Bryce Merrick

HDPE. Dredging Pipeline

A new concept in the storage of liquefied chemical and petrochemical gases Zero leakage Zero fugitive emissions

Installation restrictions for length of sections should also be noted.

INTERLOCKED METAL HOSE

SECTION PRESSURE TESTING OF PIPING

Ropes for Subsea Cable Laying

WHEATLEY Series 500 Swing Check Valve

UIB30 and UIB30H Sealed Inverted Bucket Steam Traps for use with Pipeline Connectors

RUBBER EXPANSION JOINTS

Membrane Housings. Reverse Osmosis Nanofiltration Ultrafiltration Microfiltration

MECHANICAL REDESIGN OF ION EXCHANGE RESIN VESSEL BOTTOMS AT HULETT REFINERY

FLAMMABLE GASES AND FLAMMABLE CRYOGENIC FLUIDS

CSO/STORMWATER MANAGEMENT. HYDROVEX VHV / SVHV Vertical Vortex Flow Regulator

Eaton Filtration, LLC

Plumbing Products FLOOR DRAIN CLEANOUT GATE VALVE BALL VALVE.

Steam Trap BK BK 212-ASME. Original Installation Instructions English

TRUSTED. DURABLE. RELIABLE.

Cleaning. Introduction Page

COOPER POWER SERIES. Manual or Hostick Operable, Padlockable 150 A Tap-Changer Switch Installation Instructions. Tap-Changer Switch MN800015EN

Installation Instructions and valve Maintenance Rev. 0 of 21/09/15

Transcription:

FIBERGLASS MANHOLES SANITARY SEWER LINES

Fiberglass manholes are quickly becoming more common in new installations than concrete. Sanitary sewer lines create an incredibly corrosive environment which causes leaks in concrete manholes and even worse, infiltration. Infiltration allows ground water to enter the waste line overburdening the system and increasing costs. Municipalities across the nation are investing billions in the rehab of failing concrete manholes. Fiberglass manholes from Containment Solutions, Inc (CSI) are non-corrosive, and watertight. Fiberglass is simply the superior choice in manholes. Formerly a division of Owens-Corning, the world s largest fiberglass producer, we are committed to continuing our tradition of excellence and we want to continue to earn your trust, just as we have for decades. After all, we have been manufacturing underground tanks and manholes for over 45 years and tens-of-thousands have been installed throughout the US, in many different types of soil, and in many different effluents, without a single failure. MANHOLE DESIGN Quality is built into each manhole. We start with a time-proven design which distributes loads evenly to reduce stress. CSI manholes are fabricated using high quality resin, and glass, specifically designed to improve corrosion resistance and overall performance. This laminate matrix is centrifugally fused through a computer automated process from the inside-out using rotating mandrels. This manufacturing process produces a smooth, high gloss, inner surface that is maintenance free. Most importantly, fiberglass is virtually impervious to the increasingly hostile environment common in sewers. EASE OF INSTALLATION Fiberglass manholes are approximately 10% of the weight of concrete manholes so they are easier and safer to handle. This also allows for a safer and less costly installation because there is no need for heavy equipment and less manpower is required to move the manhole. Maintenance free, high gloss, inner surface. REDUCE INFILTRATION In most cases, ordinary concrete manholes are installed in sections, otherwise they would be too heavy to move. This creates a joint the source of most leaks every three feet. CSI manholes have no joints. They are available in standard one-piece lengths which prevents infiltration or exfiltration. VARIOUS DIAMETERS WITH LENGTHS UP TO 50' SUPERIOR AUTOMATED PROCESS 2 FIBERGLASS MANHOLE

WILL NOT FLOAT CSI manholes are installed in a concrete base (6 X 6 X 6 for 42 and 48 refer to Manhole Installation Instructions). The combination of manhole weight, slab weight, and weight of the soil wedge on the protruding 12 of slab more than offset the buoyancy by a factor of more than five to one. STRUCTURALLY SOUND EXCEEDS H-20 LOAD RATING Manhole failures mean that fluids can enter or exit a system. If the manhole leaks out into a body of water the environmental liability can be catastrophic. On the other hand, if a manhole is allowing ground water to enter the sewer line, the additional volume flowing through the system has a ripple effect that causes structural instability and exponentially increases management costs. CSI manholes are designed to withstand the rigid requirements of ASTM D3753 and must withstand a minimum eccentric load of 40,000 pounds. CSI manholes exceed the AASHTO H-20 Axle Load rating by two and a half times. CSI manholes resist structural fatigue, will not crack, crumble, or leak during normal design life. Concrete or brick manholes can be weakened due to movement caused by traffic shifting soil, temperature changes, and cyclical groundwater loading. CSI manholes are built in a watertight monolithic design absent of potential leaks. CSI manholes arrive to the site ready for installation saving significant time and money. CORROSION RESISTANT ADHESIVE JOINT MODELS AVAILABLE FEATURES & BENEFITS H20 Load Rated Corrosion resistance Structural strength Lightweight Monolithic design ASTM D 3753 Diameters (42, 48, 54, 60, 66, 72, 96, 120 ) Lengths 3 to 50 (Custom lengths available) Cone openings (Concentric 22 1/2, 32, 38 Eccentric - 22 1/2 ) 20-year corrosion and structural limited warranty FIBERGLASS MANHOLE 3

A B C CSI FIBERGLASS MANHOLE A. Standard H20 Ring and Cover Accepts most common rings and covers D B. Adjustment Rings Built to finished grade with standard materials C. Manhole Cone Exceeds H-20 wheel loads E D. Manhole Barrel/Cylinder Lengths from 3' in half foot increments, frictionless inner surface, diameters available from 42-120 E. Piping Options include: PVC, fiberglass, clay, steel, and more F F. Concrete Slab Optional factory fabrication for quick installation G G. Lift Lugs Aid in the loading and unloading process 4 FIBERGLASS MANHOLE

Manhole with Fiberglass Bench/Invert and Solid Bottom Open Bottom Fiberglass Manhole FIBERGLASS MANHOLE 5

ACCESSORIES AVAILABLE FOR CUSTOM MANHOLE FABRICATION PVC stubouts Flexible rubber boots Fiberglass watertight bottoms Fiberglass benches and inverts Factory installed concrete slab Bottom flanges PROPERTIES OF CSI MANHOLES Diameter of fiberglass manholes available: 42, 48, 54, 60, 66, 72, 96, 120 Lengths: 3 to 50 (Custom lengths available) Cone Openings: Concentric 22½, 32, 38 Eccentric 22½ As our cities expand outward, millions of gallons of hydrogen sulfide rich effluents must spend long periods of time in our sewer systems before they reach a treatment plant. The combination of these effluents, a warm humid atmosphere and long retention times create perfect conditions for microbiologically induced corrosion (MIC). Corrosion is the mortal enemy of ordinary manholes, but not of fiberglass. CSI fiberglass manholes are not susceptible to MIC corrosion, thus have much longer service lives and street closings, service disruption, and costly repairs can be avoided. While concrete and brick manholes were once believed to last 50 years, many fail within the first 5-10 years. THE PROVEN SOLUTION Thousands of our manholes have been installed over a wide area, in many different types of soil, and many different effluents. CSI fiberglass manholes have been in service for more than forty-five years and many of these installations are in busy streets. Actual experience has proven to city managers, public works officials, and hundreds of others who are responsible for municipal wastewater collection systems, that CSI manholes are the very best you can put in the ground. ASTM STANDARDS CSI manholes are constructed and tested in accordance with the following ASTM standards and test methods (Independent, third party test result documentation with ASTM D-3753 verify compliance are available upon request): ASTM D-3753 Standard Specification of Glass-Fiber Reinforced Polyester Manholes ASTM C-581 Practice for Determining Chemical Resistance of Chemical Thermosetting Resins Used in Glass Fiber Reinforced Structures Intended for Liquid Service ASTM D-2412 Test Method for Determination of External Loading Characteristics of Plastic Pipe by Parallel Plate Loading ASTM D-695 Test Methods for Compressive Properties of Rigid Plastics ASTM D-2584 Test Method of Ignition Loss of Cured Reinforced Resins CSI manholes are monolithic, corrosion resistant and lightweight. 6 FIBERGLASS MANHOLE

MANHOLE SHORT FORM SPECIFICATION Glass-Fiber Reinforced Polyester Manholes shall be a one-piece monolithic designed unit constructed of glass-fiber reinforced, supplier certified, unsaturated commercial grade polyester resin. FRP manholes shall be manufactured in diameters of 36 through 120 with lengths up to 50. Manholes will be manufactured by Containment Solutions, Inc. Manholes shall conform to the following design criteria: A. ASTM D-3753: Standard Specification for Glass-Fiber Reinforced Polyester Manholes. B. ASTM C-581: Practice for Determining Chemical Resistance of Chemical Thermosetting Resins Used in Glass-Fiber Reinforced Structures Intended for Liquid Service. C. ASTM D-2412: Test Method for Determination of External Loading Characteristics of Plastic Pipe by Parallel Plate Loading. D. ASTM D-695: Test Methods for Compressive Properties of Rigid Plastics. E. ASTM D-2584: Test Method for Ignition Loss of Cured Reinforced Resins. F. ASTM D-790: Test Method for Flexural Properties of Unreinforced and Reinforced Plastics and electrical Insulating Materials. G. ASTM D-2583: Test Method for Indentation Hardness of Rigid Plastics by means of a Barcol Impressor. H. AASHTO H-20: Axle Loading. Submittals: A. Catalog Data: Submit copies of manufacturer s literature B. Installation Instructions: Submit copies of manufacturer s instructions Stubouts and Connections: Several methods may be used to connect primary and secondary lines when installing fiberglass manholes A. Make piping cutouts in the manhole and setting over the pipe and grout B. Use flexible resilient rubber connectors in the manhole wall C. Install appropriate PVC pipe to bell/spigot connections on manhole Fiberglass manholes are easy to work with which allows for a wide variety of other connection possibilities. Installation Instructions: Refer to CSI Fiberglass Manhole Installation Instructions (Pub. No. MAN4033) Handling and Storage: Do not drop or impact the fiberglass manhole. Lift manhole with two slings on spreader bar in horizontal position or an appropriately sized timber or steel beam, 8 longer than the cone top opening, inserted crosswise inside the manhole to the underside of the collar with a rope or chain attached to backhoe or other lifting device. Manhole may be rolled, however, ensure that ground is smooth and free of rocks, debris, etc. Use of chains or cables in contact with manhole surface is prohibited. While Containment Solutions has taken every precaution as to the accuracy of content and data presented herein, Containment Solutions cannot be held responsible for the individual interpretation of the data presented, any loss or damage to any property whatsoever, injury or death to any person whatsoever, or any claims, demands, actions, complaints, proceedings, judgement, losses, damages, compensation, liabilities, cost or charges, however arising from the unauthorized undirected use of this handbook or the data it contains. FIBERGLASS MANHOLE 7

CONTAINMENT SOLUTIONS MANUFACTURES: Fiberglass Manholes and Wetwells Underground Fiberglass Storage Tanks Aboveground Steel Storage Tanks Automotive Oil and Lubricant Storage Tanks Oil/Water Separators and Interceptors Flowtite Water Tanks Chemical Storage Tanks Field Service 333 North Rivershire Dr. Conroe, TX 77304 Phone: (936) 756-7731 www.containmentsolutions.com Copyright Containment Solutions, Inc. All Rights Reserved April 2017 Pub. No. MAN 4001F