Luxor Automatic bollards

Similar documents
TECHNICAL MANUAL HEAVY DUTY HORIZONTAL MICRO-COMPRESSOR Reference: RCMPH

USER S MANUAL BASIC HORIZONTAL OIL-LUBRICATED MICROCOMPRESSOR Reference: RCMPBH

Manual winch MANISTOR 100 and 200

30T A/Manual Hydraulic Shop Press

Vibration isolation system 1VIS10W. User manual

Declaration of Conformity as per Directive 97/23/EC

MUELLER. A Wall Type. Indicator Post. Reliable Connections. General Information 2. Technical Data/ Dimensions 3. Installation 4-5.

e.do Gripper Safety requirements, technical features and assembly and integration instructions

Measurement accessories METPOINT OCV for the measurement in systems up to 40 bar

Mounting and Operating Instructions EB 8546 EN. Type 4708 Supply Pressure Regulators. Translation of original instructions. Type Type

KTM OM-2 SPLIT BODY FLOATING BALL VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

TEST BENCH SAFETY VALVES ¼ - 5 DN10 DN125

Operating Instructions

Installation and Operating Instructions Bypass Flow Meter DST

Instruction Manual AC350 GUIDED-TYPE FALL ARRESTER ON RIGID ANCHORAGE LINE EN 353-1:2002

MUELLER. A A Adjustable. Vertical Indicator Posts. Reliable Connections. General Information 2. Technical Data 3.

Hand winch MANIBOX GR

MUELLER A A Non-Adjustable. Vertical Indicator Posts. Reliable Connections. General Information 2. Technical Data 3.

TECHNICAL INFORMATION

3-PIECE BALL VALVE, 3600 PSI/ PN 248, WITH ISO DIRECT MOUNTING PAD 306M SERIES/ PED Category II

STAGE, STADIUM & X-TREME SHOT.

HANDBOOK. Squeeze Off Unit SOU 250. Please refer any queries to:

Incorrect installation, adjustment, or misuse of this burner could result severe personal injury, or substantial property damage.

PLAQUE MFM0680 UNDERWATER LIGHT. Operating Instructions

Guardian Series Lift Tables Service Manual

Magnetic level switch type MR783 Instruction Manual

MANUALLY OPERATED VALVE VLM SYNCROFLUX TECHNICAL MANUAL MT042/E

Flowmeter. Original operating manual DFM

Installation Instructions

Pressure Injection Cell Operator s Manual

INSTRUCTION MANUAL COMPACT PRESS. SWITCHES SERIES PCS & PCA

OFFICINE OROBICHE S.p.A. 1/9

HYDRAULIC MOBILE LIFTING TABLE

INSTRUCTIONS AND MAINTENANCE MANUAL SERIES: K

Repair instructions. Pivot bushing replacement. XL-AS10001RM-en-DE Rev B

SpanSet Gotcha CRD User Instructions. SpanSet Certified Safety

Operating Instructions. Ball valve fitting according to ZB For pressure transmitter VEGABAR 82. Document ID: 50027

Operating Instructions Part No

SPECIFICATIONS Type: Twin stack, single phase Tank: 4 gallon Air Output: PSI; PSI Max PSI: 125 PSI HP: 1.

Differential Pressure Regulator Type Type 45-6 (0.1 to 1 bar, DN 15) Mounting and Operating Instructions EB 3226 EN

Pressure relief valve

ATS430 turbidity sensor Retractable insertion assembly

Halsey Taylor Owners Manual 4410 Freeze Resistant Tubular Fountain STOP!

Welker Sampler. Model GSS-1. Installation, Operation, and Maintenance Manual

Mounting and Operating Instructions EB EN. Type Supply Pressure Regulator. with increased air capacity

Pressure relief valve

Cantilever Brake. Dealer's Manual. ROAD MTB Trekking. City Touring/ Comfort Bike

Operating Manual VSA100A. tina29e1 ( )

OR-V 40 P BETRIEBSANLEITUNG DEUTSCH ENGLISH FRANÇAIS ITALIANO MODE D'EMPLOI ISTRUZIONI PER L'USO

INSTALLATION MANUAL Matheson Tri-Gas Cabinet Enclosures

AIR COMPRESSOR OPERATION & MAINTENANCE INSTRUCTIONS MODEL NO: CHAMP 3 PART NO: LS0115

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25

OR-V 41 P BETRIEBSANLEITUNG DEUTSCH ENGLISH FRANÇAIS ITALIANO MODE D'EMPLOI ISTRUZIONI PER L'USO

Installation Instructions

INSTALLATION PROCEDURE FOR OPGW FIBER OPTIC CABLES

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly.

INSTALLATION INSTRUCTIONS

Poollift Delphin. Version: February, 2015 MANUAL AND OPERATING INSTRUCTIONS

MAGICFX CONFETTIPISTOL USER AND INSTALLATION MANUAL

80 Litre Suction Oil Drainer

Declaration of Conformity as per Directive 97/23/EC

STEYR evo 10 E STEYR evo 10 E Compact

FLANGED MULTI-PORT BALL VALVES

Type Operating Instructions. 2/2-way solenoid valve 2/2-Wege Magnetventil Electrovanne 2/2 voies.

OPERATING MANUAL CHEMTRAC 840M MANUAL RETRACTABLE PROCESS HOLDER

RESCUE LIFTING DEVICE RUP 503-[...] AT 053-[...] xx

Low Wind High Yields Series

QPL... Pressure Switches. Siemens Building Technologies HVAC Products

Target disk flowmeter Series DP. Instructions manual DP65 DP500. R-MI-DP Rev.: 4 English version

Size : Connection Ends : Min Temperature : Max Temperature : Materials : Cast iron body

HANDBOOK. Squeeze Off Unit SOU 400. Please refer any queries to:

Code AWC20HP Air Compressor

SAPAG. Safety valves, type 5700 Storage, Use, Operation and Maintenance Instructions. IMPORTANT NOTICE

Declaration of Conformity as per Directive 97/23/EC

Halsey Taylor Owners Manual STOP!

Hydro-Pneumatic Cylinder HPL-B / HPL-C

BRAKE WINCH RUP 503-[T/BT] EQUIPMENT FOR LIFTING LOADS. AT 053-[T/BT] xx

Hot Tapping Machine. OPERATIONS MANUAL and OPERATING INSTRUCTIONS

6301 TYPE CAST IRON SAFETY VALVES

Float operated valve TYPE (SWDS)

Telefon (+45) Telefax (+45)

CAST IRON SAFETY VALVE TYPE 6301

2-JAW SELF-CENTERING PARALLEL PNEUMATIC GRIPPER (SERIES SZ)

Water Safety Shut-off Valve HON 790

2 GALLON TWIN STACK AIR COMPRESSOR W/ HOSE REEL

Ball valve. Operating instructions for series. Version BA Print-No TR MA DE Rev001

Chapter 2 Rigging. Cutting Wire Rope. Anchoring Wire Rope to Drum. Winding Wire Rope Onto Drum

Spilt body Flange ball valve. TC-205MFF-PN1640 User Manual English Version. Document No: TC-205MFF-PN1640.Ur-manual. Date: 2007/04/2617. Version: 1.

Installation, Operating & Maintenance Instructions. All-metal gate valve with extended pneumatic actuator. Series 48 DN mm (I.D.

FLANGED TWO-PIECE BALL VALVES

A. TO PREPARE THE MACHINE FOR USE.

Bray/ VAAS O-Ported Series Knife Gate Valve 770/780 Series Operation and Maintenance Manual

BOSS PULISCI PROVA IMPIANTI MEDIA

with self-sealing gas valve system

INSTRUCTIONS & MAINTENANCE SHEET PORTABLE HYDRAULIC PUNCHING HEAD PH045

KTM V-PORT CONTROL BALL VALVES INSTALLATION AND OPERATION MANUAL

MODEL 200 KNIFE GATE VALVES INSTALLATION & MAINTENANCE MANUAL

Operating Instructions Part No

Dual Solenoid Gas Valve Installation

Safety. Operating instructions Solenoid valve for gas VG 6 VG 15/10 DANGER. Contents WARNING CAUTION. Changes to edition 09.14

Transcription:

Luxor Automatic bollards Installation, Use & Maintenance English EN

CONTENTS 1- Legend of symbols... Pag.3 2- Conditions of use... Pag.3 2.1- Intended use... Pag.3 2.2- Limits to use... Pag.3 3- Reference Standards... Pag.3 4- Descriptions... Pag.3 4.1- Bollard Technical features... Pag.3 4.2- Description of bollard parts... Pag.4 5- Preparing the site / location... Pag.5 5.1- Preliminary checks... Pag.5 5.2- Tools and materials... Pag.5 5.3- Overall dimensions, distances and tracings for the trenching... Pag.6 5.4- Trenching and laying the lost casing... Pag.6 5.4.1- Mounting the support structure... Pag.6 5.4.2- Trenching and laying the casing... Pag.7 5.5- Laying and connecting the bollard... Pag.9 5.5.1- Hooking up the cable-stopper plate... Pag.9 5.6- Setting up the valve unit plate... Pag.10 5.7- Hooking up the valve unit plate... Pag.11 5.8- Closing the bollard... Pag.11 6- Releasing the Bollard (optional)... Pag.12 7- Safety instructions... Pag.12 8- Maintenance... Pag.13 8.1- Periodic maintenance... Pag.13 8.2- Trouble shooting... Pag.13 8.3- Log of interventions... Pag.14 9- Phasing out and disposal... Pag.16 10- Declaration of conformity... Pag.16 Pag. 2 - Manual code: 119G9142 ver. 1.2 04/2008 URBACO S.A. - The data and information reported in this installation manual are susceptible to change at any time and without obligation on URBACO S.A. to notify users.

IMPORTANT INSTALLATION, SAFETY INSTRUCTIONS CAUTION: IMPROPER INSTALLATION MAY CAUSE SERIOUS DAMAGE, FOLLOW ALL INSTALLATION INSTRUCTIONS CAREFULLY THIS MANUAL IS ONLY FOR PROFESSIONAL OR QUALIFIED INSTALLERS 1 Legend of symbols Pag. 3 - Manual code: 119G9142 ver. 1.2 04/2008 URBACO S.A. - The data and information reported in this installation manual are susceptible to change at any time and without obligation on URBACO S.A. to notify users. This symbol tells you to read the section with particular care. This symbol tells you that the sections concern safety issues. This symbol tells you what to say to the end-users. 2 Intended use and Limits to use 2.1 Intended use This product is engineered and built exclusively to serve as explained in this technical manual. Any other use is wrongful and thus dangerous. Anything that is not described in these instructions must be considered as dangerous. URBACO refuses any liability deriving from the wrongful use of the system. 2.2 Limits of use Do not allow people or animals to linger in the vicinity of the bollard while it is in motion. Keep transmitters and any other command device out the reach of children, to prevent operator from being activated by accident. 3 Reference Standards The product in question complies with the following standards: See par. 10 Declaration of Conformity p. 17. 4 Description 4.1 Bollard technical features BPLUXE60 BPLUXF60 BPLUXG60 BPLUXE80 BPLUXF80 BPLUXG80 Weight 68 Kg 78 Kg 89 Kg 76 Kg 89 kg 101 Kg Time to surface Adjustable Time to descent 4 s 3.5 s 3 s 5 s 4.5 s 4 s Operating temperature -20 C / +70 C Working pressure 6/8 bar Maximum opening force 1918 N 1800 N 1682 N 1867 N 1727 N 1500 N

4.2 Description of bollard parts 1 a b 2 j f g h i e BPLUXE60 BPLUXF60 BPLUXG60 BPLUXE80 BPLUXF80 BPLUXG80 a 600 600 600 800 800 800 b 200 273 320 200 273 320 c 135 135 135 135 135 135 d 878 878 878 1078 1078 1078 e 393 393 413 393 393 413 f 363 363 383 363 363 383 g 197.5 197.5 197.5 197.5 197.5 197.5 h 680.5 680.5 680.5 880.5 880.5 880.5 i 452 452 473 452 452 473 j 422 422 443 422 422 443 c 1 Closing nuts and bolts 2 Cover 3 Upper centering tubes and blocking counter nuts 4 Tension rods 5 Lower centering tubes 6 Light unit 7 Body of the bollard 8 Cable stopper plate 9 Pneumatic piston 10 Securing base 11 Tension rod blocking nuts 12 Lost casing 13 Expanding recess (Cable holder) d 3 4 5 7 8 11 13 9 6 10 12 Pag. 4 - Manual code: 119G9142 ver. 1.2 04/2008 URBACO S.A. - The data and information reported in this installation manual are susceptible to change at any time and without obligation on URBACO S.A. to notify users.

5 Preparing the site / location 5.1 Preliminary checks Pag. 5 - Manual code: 119G9142 ver. 1.2 04/2008 URBACO S.A. - The data and information reported in this installation manual are susceptible to change at any time and without obligation on URBACO S.A. to notify users. - Check that there are no tubes or other impediments to the digging and laying operations./ Check that no conduits or other obstacles shall prevent from excavating and installating operations - Check the bearing and consistency of the soil./ Check the soil consistence and its loading capacity - Include an omnipolar switch on the automation s power grid, having an opening distance of the contacts that is equal or greater than 3mm./ On the power supply line provide an omnipolar disconnecting device with an opening distance between contacts equal to or larger than 3 mm. We suggest using a 10A ominipolar cut off device./ We recommend you to use a 10 A omnipolar disconnecting device. - There must not be any obstacles that could prevent the normal movement of the bollard./ Remove any obstacle that can prevent the bollard form a normal operating mode. - Position the technical centre so that it is protected from possible impacts. - Include tubing for connections. - If needed, include optical/acustic warning systems to reduce the risk of danger. 800 800 - The maximum length of the air conduits cannot exceed 100m - The maximum distance of the connection cable from the metal mass detection sensor and the coil cannot exceed 50m. Example for establishing the number of turns: the antenna holder is defined as the surface of coil multiplied by the number of turn and cannot ever exceed NA=20. For example if the L = 2m, Ea = 1m and the number of turns is 4, then NA = 2 x 1 x4 =8 < 20. Surface Number of turns < 3 m² 4 3-5 m² 3 6-10 m² 2 Direction of travel Technical centre Bollard Waterproof product Magnetic loop Sheath Ø 90 Well/Pit 400x400 Magnetic loop Sheath Ø 90 30-50 mm depending on the number of cable turns Clean and leave to dry the drain grooves before inserting the cable.

5.2 Tools and materials TOOLS: Make sure you have all the proper tools handy to make the installations in total safety and according to current legislation, we suggest handling the bollard using the proper lifting equipment. MATERIAL: Make sure you have all the materials needed for installation. Examples of the more important ones follow: -* CHARACTERISTICS OF THE CEMENT TYPES ADHESIVE: it is best to use artificial Portland cement free of components such as CPA 325. AGGREGATES: 10/20 calibre are composed of limestone or silicon which are free of salts and clays. PLASTICITY: the cement employed shall have to resist plastic deformations, the lowering onto the Abrams cone shall be between 4 and 7 cm for a conical, trunk mold 30 cm tall, having a diameter of 10 cm in the high part and of 20 cm in the low part, which is filled in four layers. DOSAGE= 350kg/m3. DRAINAGE GRAVEL: use gravel that has a grain size of between 10 and 20 mm. CHARACTERISTICS OF THE STEEL HLE steel exclusively. For any steel used, consider: - the nature of the steel and its carbon content. - the geometrical characteristics of the sections (a parameter which defines the shape of the section). - the adhesive characteristics. - the guaranteed mechanical characteristics. - the suggested use; the curvature, working, and welding factors. - the suggested use; the curvature, working, and welding factors. - the class (e.g. Fe E 40 A) When employing the steel, respect the suggestions of the manufacturer and the dimensions according to specifications and requirements. 5.3 Overall dimensions, distances and tracing for the trenching. Depending on the type of ground: cut the road surface using a disc, or remove the surface. Study the drawings below to determine the dimensions and depth of the trenching perimeter, depending on the bollard model. When laying several bollards we suggest performing a single trench taking into account the distances and pitch between the bollards. 1250 1450 9 250 7 5 3 6 2 1 4 8 135 600 800 100 300 1400 1000 1000 1400 1 Lost casing 2 Ø100 PVC drainage tube 3 Geo-textile fabric 4 Drainage gravel 5 First layer of cement (prefixing) 6 Second layer of cement 7 Tubo corrugato Ø 90 8 Third layer of cement 9 Road surface or pavement Pag. 6 - Manual code: 119G9142 ver. 1.2 04/2008 URBACO S.A. - The data and information reported in this installation manual are susceptible to change at any time and without obligation on URBACO S.A. to notify users.

5.4 Trenching and laying the lost casing 5.4.1. Mounting the support structure Before starting any trenching operations, we suggest mounting the lost casing (as explained in the leaflet included with the same). To avoid sagging and deformations during the casting phase, we supply a wooden support structure. Mount it as shown, and insert it inside the lost casing. Pag. 7 - Manual code: 119G9142 ver. 1.2 04/2008 URBACO S.A. - The data and information reported in this installation manual are susceptible to change at any time and without obligation on URBACO S.A. to notify users. 1 2 3

5.4.2. Trenching and laying the box. After removing the road surface, trench using suitable tools. Respect the dimensions mentioned in Chapter 5.3. 1 Depending on the type of soil: cut the road surface using a disc, or remove the road surface, and dig the first 1400 mm x 1400 mm trench, having a depth of 250 mm. 3 5 Continue digging a trench of about 1000 x 1000 mm that is 1000 / 1200 mm deep, depending on the height of the bollard. Once the digging is finished, lay geo-textile fabric on the bottom, which limits sinking into the gravel over time. Fill up with gravel that is 300 mm thick, and in the centre, place a Ø 100 PVC drain tube (hole in the lost casing must be placed above the PVC tube). For easier laying of the lost casing, we suggest anchoring it to some cross bars, and using a level gauge and shims, adjust the box perfectly. 4 2 Pag. 8 - Manual code: 119G9142 ver. 1.2 04/2008 URBACO S.A. - The data and information reported in this installation manual are susceptible to change at any time and without obligation on URBACO S.A. to notify users.

6 English 7 When the first layer of cement is dry, cast the second and fill the entire smaller hole. 8 When the second layer of cement is also dry, lay the PVC Ø 100 corrugate cable conduit, making sure it adheres perfectly to the hole in the box. Fix it using cement. IT 9 IT 10 Italiano IT Italiano Continue casting until you get to about 85 mm from the surface (if you wish to lay particular flooring see fig. 10) otherwise keep casting until the cement reaches the edge of the box. Italiano 1.2 04/2008 URBACO S.A. - The data and information reported in this installation manual are susceptible to change at any time and without obligation on URBACO S.A. to notify users. Pag. 9 - Manual code: 119G9142 ver. 1. EN Cast the first layer of 100 mm of cement* (careful to respect the characteristics of the cement) being careful not block the drain pipe.

5.5 Laying and connecting the bollard Screw the M20 female eye bolts diagonally onto the rods as shown in the illustration. This operation is needed for the later hoisting of the bollard (using the appropriate equipment) to insert it into the box cemented into floor. Block the cables - 5.5.2. Hooking up the cable stopper plate. Cable exit Corrugate conduit Hook up to the eye bolts and using the proper hoisting tools insert the bollard into the lost casing, making sure to block the cables by tying them to one of the rods (see illustration), to prevent from being squashed, and to also have them handy later on. Be careful that the cable exit side on the bollard corresponds to the corrugated conduit side. Before hooking up the cable stopper plate, pass all the pneumatic and electrical cables behind (fig. 1), rest the plate against the wall of the lost casing (fig. 2) and make it slide downward until it hooks up ( fig. 3). 1 Air tube (to be connected to the 2 3 flow reducer) Electrical cabling Cable stopper plate From the piston Pag. 10 - Manual code: 119G9142 ver. 1.2 04/2008 URBACO S.A. - The data and information reported in this installation manual are susceptible to change at any time and without obligation on URBACO S.A. to notify users.

5.6 Preparing the valve holder plate Here are the mounting diagrams for the valva holder plate, depending on the installation you have chosen. N.B. for the pneumatic cabling use DIN 74324 Ø 10x8 tubes Positive safety electrovalve Positive safety electro-valve + mechanical release (optional) Pag. 11 - Manual code: 119G9142 ver. 1.2 04/2008 URBACO S.A. - The data and information reported in this installation manual are susceptible to change at any time and without obligation on URBACO S.A. to notify users. Mono-stable valve To the centre Flow reducer To the piston Negative safety solenoid valve (optional) Bi-stable valve Flow reducer To the centre To the piston Valve holder plate Negative safety solenoid valve * Mechanical release (optional) Valve holder plate Mono-stable valve To the centre Bi-stable valve To the centre To the piston To the piston Release valve Flow reducer Release valve Flow reducer

5.7 Hooking up the valve Before inserting the valve holder plate, we suggest performing all electrical connections and setting up the proper measurements of the pneumatic ones, so that they can be easily connected to the plate once it is in place. To hook up the valve holder plate, lean the lower part of the plate on the apposite wings (fig. 1) and make it adhere to the wall of the lost casing (fig. 2). Make it run downwards to hook it up as shown in fig. 3. 1 2 3 1 Overall dimensions of the valves 5.8 Closing the bollard Overall dimensions of the valves Once the connections are done, fix the cover, by placing it so that the URBACO name is on the cable side. Insert the M12x35 flush screw as shown and screw on the bolts (with washers) without tightening them.make the bollard go up and down a few times and tighten the nuts when the piston is in the up position. 2 Overall dimensions of the valves Cover the nut holes, using the apposite caps. Pag. 12 - Manual code: 119G9142 ver. 1.2 04/2008 URBACO S.A. - The data and information reported in this installation manual are susceptible to change at any time and without obligation on URBACO S.A. to notify users.

6 Release the bollard (if installed) To activate the bollard release (if included, being that it is optional) insert the issued key in the apposite hole, see fig. 1 and turn the key counter-clockwise. The bollard begins to descend (fig. 2) N.B. : if the installation is under pressure, by raising the lever to its initial position, the piston will rise. 1 2 Pag. 13 - Manual code: 119G9142 ver. 1.2 04/2008 URBACO S.A. - The data and information reported in this installation manual are susceptible to change at any time and without obligation on URBACO S.A. to notify users. 7 Safety instructions Important safety instructionsù This product must only be employed for its originally intended use. Any other use is wrong and potentially dangerous. The manufacturer cannot be held liable for any damages resulting from wrongful, erroneous or negligent uses. Do not step within the reach of the automation while it is in operation. Do not exercise force against the motion of the operator as this could result in potentially dangerous situations. Do not allow children to play or linger within reach of the automated device. Keep transmitters and any other command device out the reach of children, to prevent operator from being activated by accident. Magnetic loop Magnetic loop In the event of anomalous behaviour, stop using the operator immediately. Provide for adequate safety systems such as magnetic loops, traffic lights or any device that shall prevent dangerous situations. Danger! High voltage No transit during operation

8 Maintenance 8.1 Periodic maintenance - Before performing any maintenance procedures, cut off the main power, to prevent possible accidents due to gate movement. Check point Check and maintenance 8.2 Trouble shooting MALFUNCTIONS POSSIBLE CAUSES REMEDIES The solenoid valve is supplied (check it by using a voltmeter) but the bollards doesn t move upwards. The bollard surfaces in an irregular manner./ The bollard move upwards irregularly The bollard surfaces, but stops before reaching the final up position. The bollard descends but stops before the down position. The compressor works too frequently. The air doesn t come to the solenoid valve The flux regulator is closed Solenoid valve winding has burnt out Presence of foreign bodies on the guide Air pressure is not sufficient The cover was placed wrongly. There are foreign objects in the guide. There is a foreign object under the carriage or under the bollard head. Air leak. Air leak at the solenoid valve release. The pressure is too high. 2 3 1 Compressor functioning x x 2 Cleaning of the centre x x 3 Endstop sensors x x 4 Solenoid valve x x 5 No air leak x x 6 Cooling fans x x 7 Heating unit x x 8 Automatic drainage functioning x x 9 Metal detecting loops x x 4 5 6 7 8 Check the compressor and the air circuit Open the flux regulator Change the winding 9 10 Check the guides status. Clean. Check and adjust the pressure of the pressure-switch (6 8 bar). 11 Check the position of the cover. Check the condition of the guides. Clean and lubricate. Clean the bottom of the casing and the lower part of the bollard head. 12 Check the flexible air tube and the couplings (if needed use foam spray to detect leaks). Purge the circuit and clean (or replace) the electrovalve (foreign objects in the air circuit). Check that pressure switch (6 8 bar when working). Pag. 14 - Manual code: 119G9142 ver. 1.2 04/2008 URBACO S.A. - The data and information reported in this installation manual are susceptible to change at any time and without obligation on URBACO S.A. to notify users.

8.3 Log of interventions Pag. 15 - Manual code: 119G9142 ver. 1.2 04/2008 URBACO S.A. - The data and information reported in this installation manual are susceptible to change at any time and without obligation on URBACO S.A. to notify users. Check point Checking and maintenance YES NO Other operations performede 1 Securing the cover 2 slide ring 3 Endpoint sensors 4 Electrovalve 5 No air leaks 6 Draining efficacy 7 Positioning the cover 8 Luminous crown 9 Metal mass detection coils Installers stamp Date of intervention Operator s name Technician s signature Firma committente Check point Checking and maintenance YES NO Other operations performede 1 Securing the cover 2 slide ring 3 Endpoint sensors 4 Electrovalve 5 No air leaks 6 Draining efficacy 7 Positioning the cover 8 Luminous crown 9 Metal mass detection coils Installers stamp Date of intervention Operator s name Technician s signature Firma committente Check point Checking and maintenance YES NO Other operations performede 1 Securing the cover 2 slide ring 3 Endpoint sensors 4 Electrovalve 5 No air leaks 6 Draining efficacy 7 Positioning the cover 8 Luminous crown 9 Metal mass detection coils Installers stamp Date of intervention Operator s name Technician s signature Firma committente

8.3 Registro interventi Check point Checking and maintenance YES NO Other operations performede 1 Securing the cover 2 slide ring 3 Endpoint sensors 4 Electrovalve 5 No air leaks 6 Draining efficacy 7 Positioning the cover 8 Luminous crown 9 Metal mass detection coils Installers stamp Date of intervention Operator s name Technician s signature Firma committente Check point Checking and maintenance YES NO Other operations performede 1 Securing the cover 2 slide ring 3 Endpoint sensors 4 Electrovalve 5 No air leaks 6 Draining efficacy 7 Positioning the cover 8 Luminous crown 9 Metal mass detection coils Installers stamp Date of intervention Operator s name Technician s signature Firma committente Check point Checking and maintenance YES NO Other operations performede 1 Securing the cover 2 slide ring 3 Endpoint sensors 4 Electrovalve 5 No air leaks 6 Draining efficacy 7 Positioning the cover 8 Luminous crown 9 Metal mass detection coils Installers stamp Date of intervention Operator s name Technician s signature Firma committente Pag. 16 - Manual code: 119G9142 ver. 1.2 04/2008 URBACO S.A. - The data and information reported in this installation manual are susceptible to change at any time and without obligation on URBACO S.A. to notify users.

Check point Checking and maintenance YES NO Other operations performede 1 Securing the cover 2 slide ring 3 Endpoint sensors 4 Electrovalve 5 No air leaks 6 Draining efficacy 7 Positioning the cover 8 Luminous crown 9 Metal mass detection coils Pag. 17 - Manual code: 119G9142 ver. 1.2 04/2008 URBACO S.A. - The data and information reported in this installation manual are susceptible to change at any time and without obligation on URBACO S.A. to notify users. Installers stamp 9 Phasing out and disposal Date of intervention Operator s name Technician s signature Firma committente We kindly ask you to also safeguard the envirnoment, because we at URBACO considere it to be one of the fundamental elements of development of its market and operational strategies. You can do this by simply following simple disposing instructions : DISPOSING OF THE PACKAGING The components of the packaging (i.e. cardboard, plastic, etc.) are solid urban waste and can be disposed of without problems, just throw them out in the proper, correspoding recycling bins. The components of the packaging (i.e. cardboard, plastic, etc.) are solid urban waste and can be disposed of without problems, just throw them out in the proper, correspoding recycling bins. DO NOT DISPOSE OF IN THE ENVIRONMENT! PRODUCT DISPOSAL Our products are made of different types of materials. Most of these (i.e. aluminium, plastic, iron, electrical cables) are to be disposed of as solid urban waste. These can be recycled through separate waste collection and disposal at authorised facilities. Other components (i.e. electronic cards, remote control batteries, etc.) may contain hazardous materials. Thus, they must be treated and hand over to special firms authorised to properly dispose of them. Before acting, always check the specific, current legislation in your location. DO NOT DISPOSE OF IN THE ENVIRONMENT! 10 Declaration of conformity URBACO S.A. Z.A. du Couquiou 84320 ENTRAIGUES FRANCE Declares under its own responsibility that the equipments listed below: LUXOR AUTOMATIC RETRACTABLE BOLLARDS BPLUXE60/G/R, BPLUXE80/G/R, PLUXF60/G/R, BPLUXF80/G/R, BPLUXG60/G/R, BPLUXG80/G/R, LUXOR TECHNICAL CENTERS CC6U200PR, CC6U200PRS, LUXOR COMPLEMENTARY ACCESSORIES COPURA-LUX, COKCHGT-LUX, BOEVP-LUX, BOEVB-LUX, COVF-LUX, KITBEA-LUX, comply with the National Law related to the following European Directives and to the applicable parts of the following Standards. MANUFACTURER S DECLARATION Pursuant to annex II A of the Machinery Directive 98/37/EC --- DIRECTIVES --- 98/37/CE - 98/79/CE 2004/108/CE 2006/95/CE 87/404/CEE 97/37/CE MACHINERY DIRECTIVE ELECTROMAGNETIC COMPATIBILITY DIRECTIVE LOW VOLTAGE DIRECTIVE SIMPLE PRESSURE VESSELS DIRECTIVE PRESSURE EQUIPMENT DIRECTIVE --- STANDARDS --- EN 60204-1 EN 1050 EN 60529 EN 60068-2 EN 61000-6-2 EN 61000-6-3 NF P 98-310 EN 3744 EN 11201 EN 1012-1 IMPORTANT WARNING! This statement is legally binding only if the specifi cations in the supplied instruction manual have been properly followed. Do not use the equipment specifi ed here above, before completing the full installationin full compliance with the Machinery Directive 98/37/EC. the Chairman Andrea Menuzzo

URBACO SA ZA du Couquiou 84320 ENTRAIGUES -FRANCE www.urbaco.com English - Manual code: 119G9142 ver. 1.2 04/2008 URBACO SA - The data and information reported in this installation manual are susceptible to change at any time and without obligation on URBACO SA to notify users.