USER'S GUIDE. Digital Barometers with Analog Output PTB210 Series M210670EN-B

Similar documents
PTB210 Series Digital Barometers with Analog Output USER'S GUIDE

USER'S GUIDE. Digital Barometers with Serial Output PTB210 Series M210669EN-D

PTB210 Series Digital Barometers with Serial Output USER S GUIDE

USER'S GUIDE. Vaisala CARBOCAP Carbon Dioxide Calibrator for the GMP220 series probes GM K220 U421EN-1.1

E2K-L. Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid. Liquid Level Sensor. Ordering Information

URC Voltage Sensor SEN-VOLT for use with MRX units containing sensor ports

E8AA. Pressure Sensor of Stainless Steel Construction Is Ideal for a Wide Range of Applications. Pressure Sensor (Stainless Steel Diaphragm)

Installation and Operation Manual

User's Manual. Heavy Duty Dissolved Oxygen Meter. Model

GasSense NDIR User Manual

METEOR LSR36500 LIGHTING UNDERWATER POOL LIGHT. Operating Instructions

In Vivo Scientific, LLC INSTRUCTION MANUAL

O3 3E 1 F Gas Sensor Module

Hand-held Carbon Dioxide Meter GM70 USER'S GUIDE. M010139en-A August 2001

ASDX Series Silicon Pressure Sensors

E X R A D I N Spherical Ion Chambers A3. A4 REF DOC #

LM6 LEATHER MOISTURE METER

CSA Sample Draw Aspirator Adapter Operator s Manual

! Warning, refer to accompanying documents.

3800 SERIES END SUCTION PUMP REPAIR PARTS INDEX. Model Model 3804

Modular skylight warranty

Model FS5001B VA.1. MEMS Mass Flow Sensors ISO 9001 ISO OHSAS 18001

INSTALLATION & MAINTENANCE INSTRUCTIONS

RAM 4021 Operation Manual

RK-IR Sample Draw Aspirator Adapter Operator s Manual

IDL01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05

Instruction Manual AD 1000 / BA 1000 Absolute Pressure Sensor

EC214 EC215 - EC215R Bench Conductivity Meters

INSTRUCTION MANUAL MP4AR Remote Convection Gauge Range: 1 x 10-3 Torr to 1 x 10+3 Torr

The Univentor 1250 Anaesthesia Unit

Model SM/PL Series. Calibration Guide. Precision Loads. Anritsu Company 490 Jarvis Drive Morgan Hill, CA USA

PRESSURE SENSOR - ABSOLUTE (0 TO 700 kpa)

FTC130 Transmitter. Operating Manual

DEEPSEA. LED Micro SeaCam POWER & LIGHT. Operator s Manual. Original Instruction Ruffin Road San Diego, CA USA

AMS 2710 PCB pressure sensor module with V output

BAROMETER PRESSURE STANDARD PRESSURE CONTROLLER

NOVALYNX CORPORATION MODEL WEATHER STATION INSTRUCTION MANUAL

Transmitter CS 21 Operation Manual

SERIES L4E & L6E LADDER EXTENSIONS

TL-12 FLUSH TANK. Manual Ref. # MN-??? Polyurethane Machinery Corp. REVISION 1.0

RAM 4021-DPX Operation Manual

Precision pressure sensor Basic version Model CPT6020

Gas Sampling Fitting with MK2.1 and L-Probe

Installation and Operation Manual

HI 2314 HI 2315 HI 23151

WARRANTY, QUICK START GUIDE

86BSD Backside Digital Output

T i m i n g S y s t e m s. RACEAMERICA, Inc. P.O. Box 3469 Santa Clara, CA (408)

USER'S GUIDE. Vaisala Balloon Launcher FB32 M210980EN-A

PULSAR 5000 SERIES OPERATING & INSTALLATION INSTRUCTIONS SERIES 5000 PLEASE READ CAREFULLY BEFORE INSTALLING

Instruction Manual LIMITED 1 YEAR WARRANTY. Hydraulic Punch Driver Read this material before using this product.

RK LEL Sample Draw Aspirator Adapter Operator s Manual

INSTRUCTION MANUAL. FLOW CONTROL DRAWERS MANUAL / PLC CONTROL SERIES Model Version Perma Pure LLC Tel:

SX150A. Features. Typical Applications. Description

PM105 PRESSURE METER USER S MANUAL

CS115 BAROMETRIC PRESSURE SENSOR INSTRUCTION MANUAL

SDS -Series 4C-D201/-D202 Supplemental Drying System User s Manual

Model ASSEMBLY and OPERATING INSTRUCTIONS

Norrsken Family Booklet

PLAQUE MFM0680 UNDERWATER LIGHT. Operating Instructions

GETZ EQUIPMENT INNOVATORS PART NO.: 9G59554 MODEL: MS 36 SC-R HYDROSTATIC TEST PUMP

RGC-IR Remote Gas Calibrator for IR400

NOVALYNX CORPORATION MODEL BAROMETRIC PRESSURE SENSOR PCB MODEL BAROMETRIC PRESSURE SENSOR IN NEMA ENCLOSURE INSTRUCTION MANUAL

60 farm jack. Distributed exclusively by Harbor Freight Tools Mission Oaks Blvd., Camarillo, CA 93011

Installation, Operation and Maintenance Manual. TSV Temperature Shut-off Valve SPD Rev. 6 10/07

User s Guide Temperature Sensor Converter TSC-599

SPS-5. Rate Computing Scale. Operation Manual

6 digital caliper with case

INSTRUCTIONS PARTS LIST U.S. PAT: 6,874,404; 6,516,707; 6,223,645

Operation Manual. Pro He Alarm TM. Helium Analyzer. Rev 08.17

User s Guide. Pressure Controller for liquid delivery systems

E X R A D I N. Parallel Plate Ion Chambers User Manual DOC #

INSTRUCTION MANUAL. Includes: OPERATION SETUP USE & CARE SERVICE. SPORTS ATTACK LLC

92831 TEL: (714) FAX:

OPTIBAR P 1010 C Technical Datasheet

92831 TEL: (714) FAX:

PLEASE READ CAREFULLY BEFORE INSTALLING OR USING MEGA POOL SAVER MPS 1100

Calibration Gas Instrument INSTRUCTION MANUAL. Release I. Advanced Calibration Designs, Inc.

210 Series Transmitter with External Electrochemical Sensor

DM01. Please visit our website: Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

Compact Triple Cabinet Outlet Station Model Installation and Operating Instructions

Instruction Manual BA90 Precision Barometer

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

DPC-30 DPC-100. Reference Manual

MODEL 100 NITROGEN INFLATION CART

WATER HEATER THERMAL EXPANSION TANKS Owner s Manual. Safety Instructions Installation Maintenance Warranty. Models: 2-5 Gallon Capacity

ETd 04. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. Type: ETd 04. class 0.05

2000 lb manual winch

RAM 4021-PR. Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

Advanced Test Equipment Rentals ATEC (2832)

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

Ultrasonic Wind Sensor

Permanent Roof Anchors

Instruction Manual Differential Pressure Transmitter

! Unique Cable Seal System! Fully Temperature Compensated! Datalogger Compatible

MODEL CALIBRATION GAS DELIVERY SYSTEM

PPS PORTABLE POWER SUPPLY

DM01. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

NOVALYNX CORPORATION MODEL RAIN GAUGE CALIBRATOR INSTRUCTION MANUAL

Model PDT Dewpoint Transmitter

Transcription:

USER'S GUIDE Digital Barometers with Analog Output PTB210 Series M210670EN-B

PUBLISHED BY Vaisala Oyj Phone (int.): +358 9 8949 1 P.O. Box 26 Fax: +358 9 8949 2227 FIN-00421 Helsinki Finland Visit our Internet pages at http://www.vaisala.com/ Vaisala 2006 No part of this manual may be reproduced in any form or by any means, electronic or mechanical (including photocopying), nor may its contents be communicated to a third party without prior written permission of the copyright holder. The contents are subject to change without prior notice. Please observe that this manual does not create any legally binding obligations for Vaisala towards the customer or end user. All legally binding commitments and agreements are included exclusively in the applicable supply contract or Conditions of Sale.

Table of Contents CHAPTER 1 GENERAL INFORMATION... 3 Safety... 3 Feedback... 3 Recycling... 4 Trademarks... 4 License Agreement... 4 Warranty... 5 CHAPTER 2 PRODUCT DESCRIPTION... 7 CHAPTER 3 INSTALLATION... 9 Mounting... 9 Static Pressure Head... 10 Connections... 11 CHAPTER 4 CALIBRATION AND ADJUSTMENT... 13 Wizard Software... 13 Operation... 14 CHAPTER 5 TECHNICAL DATA... 19 Technical Specifications... 19 Operating Range... 19 Accuracy... 19 General... 20 Electromagnetic Compatibility... 21 Dimensions in mm (inches)... 22 VAISALA 1

User's Guide List of Figures Figure 1 PTB210 and the Standard Accessories...7 Figure 2 The BAROCAP Pressure Sensor...8 Figure 3 Different Mounting Options of the PTB210...9 Figure 4 Recommended Cable Position...10 List of Tables Table 1 Connections of the PTB210 Barometer with Analog Output...11 2 M210670EN-B

Chapter 1 General Information CHAPTER 1 GENERAL INFORMATION Safety Throughout the manual, important safety considerations are highlighted as follows: WARNING Warning alerts you to a serious hazard. If you do not read and follow instructions very carefully at this point, there is a risk of injury or even death. CAUTION Caution warns you of a potential hazard. If you do not read and follow instructions carefully at this point, the product could be damaged or important data could be lost. NOTE Note highlights important information on using the product. Feedback Vaisala Customer Documentation Team welcomes your comments and suggestions on the quality and usefulness of this publication. If you find errors or have other suggestions for improvement, please indicate the chapter, section, and page number. You can send comments to us by e-mail: manuals@vaisala.com VAISALA 3

User's Guide Recycling Recycle all applicable material. Dispose of batteries and the unit according to statutory regulations. Do not dispose of with regular household refuse. Trademarks BAROCAP is a registered trademark of Vaisala. License Agreement All rights to any software are held by Vaisala or third parties. The customer is allowed to use the software only to the extent that is provided by the applicable supply contract or Software License Agreement. 4 M210670EN-B

Chapter 1 General Information Warranty Vaisala hereby represents and warrants all Products manufactured by Vaisala and sold hereunder to be free from defects in workmanship or material during a period of twelve (12) months from the date of delivery save for products for which a special warranty is given. If any Product proves however to be defective in workmanship or material within the period herein provided Vaisala undertakes to the exclusion of any other remedy to repair or at its own option replace the defective Product or part thereof free of charge and otherwise on the same conditions as for the original Product or part without extension to original warranty time. Defective parts replaced in accordance with this clause shall be placed at the disposal of Vaisala. Vaisala also warrants the quality of all repair and service works performed by its employees to products sold by it. In case the repair or service works should appear inadequate or faulty and should this cause malfunction or nonfunction of the product to which the service was performed Vaisala shall at its free option either repair or have repaired or replace the product in question. The working hours used by employees of Vaisala for such repair or replacement shall be free of charge to the client. This service warranty shall be valid for a period of six (6) months from the date the service measures were completed. This warranty is however subject to following conditions: a) A substantiated written claim as to any alleged defects shall have been received by Vaisala within thirty (30) days after the defect or fault became known or occurred, and b) The allegedly defective Product or part shall, should Vaisala so require, be sent to the works of Vaisala or to such other place as Vaisala may indicate in writing, freight and insurance prepaid and properly packed and labelled, unless Vaisala agrees to inspect and repair the Product or replace it on site. This warranty does not however apply when the defect has been caused through a) normal wear and tear or accident; b) misuse or other unsuitable or unauthorized use of the Product or negligence or error in storing, maintaining or in handling the Product or any equipment thereof; c) wrong installation or assembly or failure to service the Product or otherwise follow Vaisala's service instructions including any repairs or installation or assembly or service made by unauthorized personnel not approved by Vaisala or replacements with parts not manufactured or supplied by Vaisala; d) modifications or changes of the Product as well as any adding to it without Vaisala's prior authorization; e) other factors depending on the Customer or a third party. Notwithstanding the aforesaid Vaisala's liability under this clause shall not apply to any defects arising out of materials, designs or instructions provided by the Customer. This warranty is expressly in lieu of and excludes all other conditions, warranties and liabilities, express or implied, whether under law, statute or otherwise, including without limitation any implied warranties of merchantability or fitness for a particular purpose and all other obligations and liabilities of Vaisala or its representatives with respect to any defect or deficiency applicable to or resulting directly or indirectly from the Products supplied hereunder, which obligations and liabilities are hereby expressly cancelled and waived. Vaisala's liability shall under no circumstances exceed the invoice price of any Product for which a warranty claim is made, nor shall Vaisala in any circumstances be liable for lost profits or other consequential loss whether direct or indirect or for special damages. VAISALA 5

User's Guide This page intentionally left blank. 6 M210670EN-B

Chapter 2 Product Description CHAPTER 2 PRODUCT DESCRIPTION The PTB210 series digital barometers are designed for various pressure ranges. The barometers with an analog output are available with different scalings between 500... 1100 hpa for 0... 5V or 0... 2.5V. The PTB210 series barometers are also available with a digital output. The PTB210 series barometers offer an excellent solution for outdoor installations. They operate in a wide temperature range. The housing of the barometer electronics provides an IP65 standardized protection against sprayed water. The rugged corrosion-resistant housing in combination with the small size facilitates easy installation and a long lifetime for the barometer. All the barometers are digitally adjusted and calibrated by using electronic working standards. This manual gives the instructions for the use of PTB210 barometers with the analog output. PTB210 barometer Fixing screw (2 pcs) Rail fastening clip Pressure fitting Attachment plate Figure 1 PTB210 and the Standard Accessories VAISALA 7

User's Guide The PTB210 barometers incorporate the BAROCAP silicon capacitive absolute pressure sensor developed by Vaisala. The sensor features excellent hysteresis and repeatability characteristics and has an outstanding temperature and long-term stability. Thin film metallization Silicon diaphragm Silicon Glass Vacuum gap Silicon Figure 2 The BAROCAP Pressure Sensor The BAROCAP pressure sensor consists of two layers of single crystal silicon having a layer of glass between them. The thinner silicon layer creates an integrated vacuum reference chamber, and forms a pressure-sensitive silicon diaphragm. The thicker silicon layer is the rigid base plate of the sensor, and it is clad with a glass dielectric. Thin film metallization has been deposited to form a capacitor electrode inside the vacuum reference chamber. The other electrode is the pressure-sensitive silicon diaphragm. The coefficients of thermal expansion of silicon and glass materials used in the BAROCAP pressure sensor are carefully matched together to minimize the temperature dependence, and to maximize the long-term stability. The BAROCAP pressure sensor is designed to achieve zero temperature dependence at 1000 hpa, and its long-term stability has been maximized by thermal ageing at an elevated temperature. 8 M210670EN-B

Chapter 3 Installation CHAPTER 3 INSTALLATION Mounting Due to the compact design of the PTB210, all you need to do is to mount the instrument, and to connect the wires. Use one of the following three mounting options. - Remove the pressure fitting, and place the barometer on a desired structure. Then, fix it with the slot headed screws, the O-ring sealing the attachment (A). - Fix the supplied attachment plate to a desired place with a screw by using the hole on the vertical part of the plate. Then, attach the barometer on the plate with the screws supplied (B). - The PTB210 can also be placed to a standard rail (DIN 35) by using the attachment plate and clip (B). Fasten the clip and barometer to the plate with the screws supplied. Finally, attach the clip to a suitable rail. A B Figure 3 Different Mounting Options of the PTB210 NOTE Always place the barometer so that the pressure fitting is downwards. VAISALA 9

User's Guide NOTE Check that the cable is not taken upwards from the barometer. This is to prevent water flowing along the cable, and gathering close to the feed-through. Figure 4 Recommended Cable Position The IP65-classified housing enables the barometer to be mounted outdoors without any additional protection. However, please take care that rainwater cannot plug the open pressure fitting. In such conditions, it is recommended to connect a piece of a tube with inner diameter of 4 mm or more to the fitting. It is also possible to use a static pressure head, SPH10/20, which protects the pressure channel from rain, and minimizes the effect of wind. Static Pressure Head Please note that the pressure fitting supplied with the transmitter is not a static pressure head, and that the transmitter cannot be used successfully as such in turbulent or high-speed static wind conditions. In demanding wind conditions, it is recommended to use Vaisala's static pressure head, SPH10/20, to which the PTB210 digital barometers can be directly integrated. This combination provides for accurate measurement in all wind conditions. 10 M210670EN-B

Chapter 3 Installation Connections Connect the wires of the PTB210 barometer according to Table 1. Use the pink wire for the supply voltage (8... 18 VDC), and the blue wire for grounding. The output signal is read from the white wire and grounded with the brown wire. The gray and green wires are used to connect the barometer to PC when using the calibration Wizard software, or to Vaisala PMI20 digital barometer display. As a ground, use the blue wire. If an external power control is used, its signal wire is connected to the yellow wire. It is recommended to isolate the free wire ends. Table 1 Connections of the PTB210 Barometer with Analog Output Wire color Signal Grey RX Green TX Blue Ground Pink Supply voltage (8... 18 VDC) Brown V out ground White Yellow V out External power control (TTL level: 1 = off, 0 = on) VAISALA 11

User's Guide This page intentionally left blank. 12 M210670EN-B

Chapter 4 Calibration and Adjustment CHAPTER 4 CALIBRATION AND ADJUSTMENT The PTB210 series barometers can be fine adjusted and calibrated against pressure standards that have high accuracy and stability as well as known traceability to international standards. By comparing the output to a reference, the user can define the corrections required for readjustment. NOTE Calibration is considered not to involve any adjustments. It is advisable to write down the previous corrections so that they will not be lost by mistake. The corrections are given by using the Wizard software; available for download at http://www.vaisala.com/ptb210wizard/. Finally, the barometer is calibrated to verify its real accuracy. Wizard Software The user-friendly Wizard software is designed to work in WIN3.X, WIN95, and NT environment. The two-point pressure corrections for the PTB210 barometers are given through the serial line by using this program. The calibration date can also be changed using the Wizard. VAISALA 13

User's Guide Operation To start the Wizard program in NT: OR 1. Double-click the My Computer icon. 2. Double-click the drive that contains the file. 3. To start the program, double-click the WIZARD.EXE-file. To start a program by using the Run command in NT 1. Click Start, and then click Run. 2. In the Open box, type the location and name of the program you want to start. Alternatively, browse the location, and choose the name of the program (WIZARD.EXE). Then, click OK. 1. Choose the COM port in use from the file menu. 2. To open the connection click the Read PTB210-button. 14 M210670EN-B

Chapter 4 Calibration and Adjustment 3. Give reference pressure values and the corresponding corrections. Calculate the corrections according to the equations below. NOTE Because the lower end of voltage output is not exactly 0 V, use as lower calibration point a value approximately 40 mv above the lower end limit. Thus with scale 600 1060 hpa and 0 5V output the lowest calibration point will be 604 hpa. P measured U *( P P ) out max min = Pmin + (1) U out max corr = ( P P ) + corr (2) new reference measured previous Example to calculate the higher end correction: Barometer scale 600 1060 hpa with the 0 5V output. - Output reading 4.8887 V - P measured = 600 + [4.8887 * (1060-600)]/5 = 1049.76 hpa - Reference value 1050 hpa - Previous correction 0.22 hpa New correction (1050-1049.76) + 0.22 = 0.46 hpa NOTE The previous corrections have to be added to the new ones (see the example above). The correction at the lower end is calculated in similar way. The new calibration date can also be given. The values are given in hpa: the reference value as whole number, and the correction with two decimals. VAISALA 15

User's Guide Reference Correction 4. To save the new corrections, click the Write PTB210-button. 16 M210670EN-B

Chapter 4 Calibration and Adjustment 5. The program then asks a password. As default, no password exists. Just click OK. The password can be used to prevent saving of any new corrections without entering it. To give a password, click the Change-button. 6. Enter a new password and confirm by re-entering it. NOTE Remember to set the MPC corrections on after given them. VAISALA 17

User's Guide This page intentionally left blank. 18 M210670EN-B

Chapter 5 Technical Data CHAPTER 5 TECHNICAL DATA Technical Specifications Operating Range Pressure range (order specified) Operating temperature range Humidity range 500... 1100 hpa 800... 1060 hpa 600... 1060 hpa 900... 1100 hpa -40... +60 C non condensing Accuracy Non linearity* Hysteresis* Repeatability* Calibration uncertainty** Total accuracy (20 C)*** ± 0.20 hpa ± 0.05 hpa ± 0.05 hpa ± 0.15 hpa ± 0.30 hpa Temperature dependence (-40... +60 C)**** ± 0.50 hpa Total accuracy*** (-40... +60 C) ± 0.60 hpa VAISALA 19

User's Guide Long term stability ± 0.10 hpa/year * Defined as the ±2 standard deviation limits of end-point non-linearity, hysteresis error or repeatability error. ** Defined as ±2 standard deviation limits of inaccuracy of the working standard including traceability to NIST. *** Defined as the root sum of the squares (RSS) of end-point non-linearity, hysteresis error, repeatability error and calibration uncertainty at room temperature. **** Defined as ±2 standard deviation limits of temperature dependence over the operating temperature range. General Outputs (order specified) Supply voltage Current consumption normal mode shutdown mode Shutdown Response time Resolution Measurement rate Load resistance Max. pressure Pressure connector Pressure fitting Housing electronics sensor Housing material Cable length Weight Instrument Cable 0... 5 VDC 0... 2.5 VDC 8... 18 VDC reverse polarity protected < 8 ma 0.2 ma ON/OFF 500 ms 300 μv 3 measurement/s >10 kohm (to ground) 5 000 hpa abs. M5 (10-32) internal thread barbed fitting for 1/8" I.D. tubing IP65 IP53 PC plastic 1, 2, 3, 5, or 10 m 110 g 28 g/m 20 M210670EN-B

Chapter 5 Technical Data Electromagnetic Compatibility Electromagnetic compatability EN61326-1:1997+ Am1:1998 + Am2:2001 Generic environment [CISPR16/22 class B, EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6] VAISALA 21

User's Guide Dimensions in mm (inches) 32 (1.26) 16 (0.63) 120 (4.72) 122.5 (4.82) 50 (1.97) 22 M210670EN-B

10 (0.39) Chapter 5 Technical Data 50.40 (1.98) 40 (1.57) 2 (0.08) 30 (1.81) 5x45 (0.2x45 ) M3 14.20 (0.56) 19 (0.75) 4.50 (0.18) 37 (1.46) 60 (2.36) M3 14x45 (0.55x45 ) ø15 (0.59) 21 (0.83) 50 (1.97) M3 VAISALA 23

www.vaisala.com *M210670EN*