JETFIRST 150 RTA SYSTEM OPERATING MANUAL Version: 2 Feb 2012

Similar documents
SSI Solaris 150 RTA Revision /27/2016 Page 1 of 9. SSI Solaris 150 RTA

Arizona State University Center for Solid State Electronics Research Issue: E Title: Heat Pulse 610 Operating Procedure Page 1 of 7

Arizona State University NanoFab XACTIX ETCHER. Rev A

OXFORD PLASMALAB 80PLUS (CLOEY)

Trion PECVD SOP IMPORTANT: NO PLASTIC, TAPE, RESISTS, OR THERMAL PASTE ARE ALLOWED IN THE CHAMBER

Standard Operating Manual

Title: Xactix XeF2 Etcher Semiconductor & Microsystems Fabrication Laboratory Revision: A Rev Date: 03/23/2016

RAPID THERMAL PROCESSOR (Annealsys AS-ONE 150) Lab Manual

Arizona State University Center for Solid State Electronic Research. Table of Contents. Issue: C Title: Oxford Plasmalab 80plus (Floey) Page 1 of 8

Usage Policies Notebook for NanoFurnace Furnace (EasyTube 3000 System)

R I T. Title: STS ASE Semiconductor & Microsystems Fabrication Laboratory Revision: Original Rev Date: 01/21/ SCOPE 2 REFERENCE DOCUMENTS

PLASMA ENHANCED CHEMICAL VAPOR DEPOSITION (PECVD) SOP OXFORD PLASMALAB SYSTEM 100

Xactix Xenon Difluoride Etcher

Birck Nanotechnology Center

Nanofabrication Facility: PECVD SOP Rev. 00, April 24

Xactix XeF2 OPERATION MANUAL

MINIBRUTE ANNEAL TUBE STANDARD OPERATION PROCEDURE

Standard Operating Manual

Basic ICP Operating Procedures

Standard Operating Manual

Instructions for Assembly, Installation, and Operation of the Gas Addition Kit Accessory with the CEM Discover Systems

Unifilm Technology PVD-300 Sputter Deposition Operation Instructions

Thermcraft Tube Furnace General Use

NORDSON MARCH PX-1000 PLASMA ASHER STANDARD OPERATING PROCEDURE Version: 1.0 July 2016

STS ICP-RIE. Scott Munro (2-4826,

Standard Operating Manual

University of Minnesota, MN Nano Center Standard Operating Procedure

MJB4 Mask Aligner Operating Procedure. Effective Date: 07/12/2012 Author(s): Jiong Hua Phone:

Arizona State University NanoFab PLASMATHERM 790 RIE. Version A

Plasma-Therm PECVD. Operating Characteristics. Operating Instructions. Typical Processes. I. Loading. II. Operating

Operating Procedures for the. SAMCO ICP RIE System

Nanofabrication Facility: ECR Etcher SOP Rev. 01b, March 06. Standard Operating Procedure for PlasmaQuest ECR II Etching

Unaxis ICP/RIE SOP Revision 8 09/30/16 Page 1 of 5. NRF Unaxis ICP/RIE Etch SOP

Edge Isolation Tool. Standard Operating Procedure. Version 1.1. Date: Prepared by, Sandeep S S. Department of Electrical Engineering

Standard Operating Manual

University of MN, Minnesota Nano Center Standard Operating Procedure

5.1.3 Mechanical Hazards Drive assemblies have sufficient power to cause injury. Keep hands, fingers, clothing and tools clear of moving parts.

LEO 1525 FEG SEM Standard Operating Procedures Mar. 6, 2012 For additional assistance, please contact the facility manager.

KARL SUSS MJB3 UV400 Mask Aligner Standard Operating Procedure

The MRL Furnaces USED FOR THIS MANUAL COVERS

LEO SEM SOP Page 1 of 9 Revision 1.4 LEO 440 SEM SOP. Leica Leo Stereoscan 440i

Unaxis PECVD. SiH4 (5% in He)

Usage Policies Notebook for STS DRIE System

Armfield Distillation Column Operation Guidelines

Oerlikon Sputtering Evaporator SOP

Cambridge NanoTech: Savannah S100. Table of Contents

Savannah S100 ALD at SCIF, UC Merced Standard operating Procedure

1)! DO NOT PROCEED BEYOND THIS MARK

In Response to a Planned Power Outage: PPMS EverCool II Shut Down and Re-start Procedure

5890II GC Standard Operating Procedure 9/2/2005

SPUTTER STATION STANDARD OPERATING PROCEDURE

Standard Operating Manual

Pegas 4000 MF Gas Mixer InstructionManual Columbus Instruments

Birck Nanotechnology Center

WATER CONTROL SYSTEM QUICK START

Usage Policies Notebook for Trion RIE / ICP Dry Etch

Touch Screen Guide. OG-1500 and OG Part # T011

Fencing Time Version 4.3

Approved by BNC Managing Director Paul Lum Date: Approved by PI (s) /Super User (s): _Peter Hosemann/Andy Minor_Date:

CircuFlow Quick Setup Guide

FireHawk M7 Interface Module Software Instructions OPERATION AND INSTRUCTIONS

Notes-PECVD: Chamber 1

Quickstart Installation Checklist (Please refer to operation manual for complete installation instructions)

Usage Policies Notebook for AMST Molecular Vapor Deposition System MVD 100

GA-300 Gas Analyzer. Technical Note. Overview. Front Panel. iworx Systems, Inc. GA-300

Standard Operating Procedure. For. PVD E-Beam

Ammonia Treatment Instructions Page 1 of 5

TABLE OF CONTENTS 2 INTRODUCTION 4 DELEGATION OF RESPONSIBILITIES 5 INSTALLATION 6

Eco Snow CO2 Clean System Operation

Equipment Operating Procedure Glove Box

Approved by Principal Investigator Date: Approved by Super User: Date:

Superconducting Susceptometer (MPMS-5S) Quantum Design Room 296 (MPMS)

XC2 Client/Server Installation & Configuration

Diver-Office. Getting Started Guide. 2007, Schlumberger Water Services

[needs to be discussed with faculty if any new material to be done]

Revised: June 7, 2017

Usage Policies Notebook for Xenon Difluoride (XeF 2 ) Isotropic Si Etch

Operation of the Perkin Elmer TGA-GC/MS

AX5000 Operational Manual

Experiment AMe-1: Small Animal Respiratory Exchange Ratio (RER)

STS PECVD Instructions

STS DRIE User SOP Location: NRF Cleanroon, Dry Etch Bay

Approved by Principal Investigator Date: Approved by Super User: Date:

Misaligned Folds Paper Feed Problems Double Feeds Won t Feed FLYER Won t Run iii

HPICAL Operation & Data Logging Procedures. Click spacebar to advance through slides 1

Douglas Call 4/11/2008 1/5. Ammonia Treatment

SOP for Karl Suss MJB3 #1 Mask Aligner

Issue: H Title: CHA E-Beam Evaporator Page 1 of 7. Table of Contents

KEM Scientific, Inc. Instruments for Science from Scientists

The ICC Duckworth-Lewis-Stern calculator. DLS Edition 2016

Standard Operating Manual

Plasma Asher: March PX-500 User guide (May-30, 2017)

Race Screen: Figure 2: Race Screen. Figure 3: Race Screen with Top Bulb Lock

Standard Operating Procedure Inductively Coupled Plasma Optical Emission Spectrometer (ICP-OES) - Thermo Scientific icap 6300

Standard Operating Manual

KARL SUSS MJB3 MASK ALIGNER STANDARD OPERATING PROCEDURE

BIOGAS COMBUSTION PLANT MAINTENANCE MANUAL

MP15 Jockey Pump Controller

Operating Procedures for Metal Evaporator I

SOP: Buck Scientific BLC-20P HPLC Operation

Transcription:

JETFIRST 150 RTA SYSTEM OPERATING MANUAL Version: 2 Feb 2012 UNIVERSITY OF TEXAS AT ARLINGTON Nanofabrication Research and Teaching Facility

TABLE OF CONTENTS 1. Introduction....2 1.1 Scope of Work.....2 1.2 Description... 3 1.3 Safety......3 2. Hardware...........3 3. Requirements........4 3.1 Training........4 3.2 System Restrictions.........4 4 Operating Procedures..........5 4.1 System Checks.......... 5 4.2 Starting a Process.............7 4.3 Loading a Sample..........12 4.4 Unloading a Sample......14 4.5 System Shutdown......14 5 Recipes.............17 5.1 Recipe Rules...17 5.2 Creating New Recipe...18 5.3 Editing an Existing recipe...21 5.4 Nanofab standard Recipes...22 2

1.0 INTRODUCTION 1.1 Scope These procedures apply to the JetFirst 150 RTA system. All maintenance should follow the procedures set forth in the manufacturer s maintenance and operations manuals. This document is for reference only. Users must be trained by Nanofab staff before operating this equipment. 1.2 Description The JetFirst 150 RTA is a rapid thermal annealing system. The system is designed to run 4 wafers. Smaller samples can be processed in this system but they must be positioned on top of a bare, clean 4 silicon wafer for processing. The JetFirst system can operate with the process chamber under reduced pressure or at atmospheric pressure. Process gases available on the system are N2, Ar, & 5%H2-95%N2 forming gas. The system is capable of controlling the process temperature through the use of a pyrometer or via direct contact with a thermocouple. 1.3 Safety 1.3.1 This machine is connected to HIGH VOLTAGE. Be very careful and remain aware of electrical hazards. If you encounter any electrical malfunctions, contact NanoFAB staff immediately 1.3.2 This machine can heat samples to > 1000C. Be aware of the possibility of high temperatures when loading/unloading the oven and allow sufficient time for your sample to cool completely. 1.3.3 This machine has an EMO (Emergency Off) switch/button mounted on the top panel to the right. The EMO switch should be pressed only in an emergency. An emergency would be fire, smoke, electrocution hazards, or an impending injury to anyone using this particular piece of equipment. If the EMO is pressed notify NanoFab staff immediately. 2.0 HARDWARE 2.1 Process Gases N2, Ar, & H2/N2 forming gas 2.2 Quartz lamp heating system annealing up to 1000 C 2.3 Vacuum pumping to 1 Torr. 3

3.0 REQUIREMENTS 3.1 Training All users must be trained on the JetFirst RTA 150 and authorized in the Nanofab reservation system to use this process system. Training is supplied by a Nanofab staff member please contact the tool owner to schedule training. 3.2 System Restrictions 3.2.1 Only 4 diameter silicon wafers may be annealed in this system. Samples may be positioned on top of a bare clean 4 silicon wafer. 3.2.2 Historical run logs must be saved to the user s personal folder on the system computer after each process run. 3.2.3 Users are limited to 1000C maximum operating temperature. 3.2.4 Users must follow and not exceed the system limits in the Temp vs Time chart located on the wall behind the RTA system and in the spec. 3.2.5 NO processing above 500C with the Thermocouple present in the system. 3.2.6 Annealing temperatures up to 500C may be run using THERMOCOUPLE CONTROL and at ATMOSPHERIC PRESSURE with one of the process gases flowing. 3.2.7 Reduced pressure (vacuum) processing can only be run using the pyrometer as the temperature controller. This type of process is limited to the 400C 1000C operating range of the pyrometer. 4

4.0 OPERATING PROCEDURES 4.1 System Checks and Start-up 4.1.1 Check the written System Logbook and verify no other users are currently running the system. If an incomplete log entry is present check to see if their sample is still present in the system. If so, you must contact the user to find out the status of the system. 4.1.2 If you plan to run a process that will exceed 500C in temperature you must verify that the Temperature Control TC (Fig. 4.1.2) is NOT installed. If the temperature control TC is installed then contact a Nanofab staff member to remove the TC before you begin processing at temperatures > 500C. Temp Control TC (Fig. 4.1.2) 4.1.3 Check to ensure the system is UP and available in the Nanofab Reservation system and that no Down to Eng tag is posted on the system. If either of these issues is encountered contact a staff member. 4.1.4 If H2 N2 forming gas will be used notify a NanoFab staff member to turn ON the delivery valves for this material. 5

4.1.5 If Argon gas will be used during processing go to the service chase behind the system and rotate the Argon cylinder valve CCW (Fig. 4.1.4a) to turn it ON. If the Argon bottle pressure, the gauge on the right, is below 200 psi notify NanoFab staff. (Fig. 4.1.4a) 4.1.6 While you are in the service chase turn ON the mechanical pump. The pump s ON/OFF switch (Fig. 4.1.5a) is located next to the power cord at the lower rear section of the pump. (Fig. 4.1.5a) 6

4.1.7 Return to the cleanroom and move to the rear of the system. If Argon or H N2 Forming gas will be used during processing then the gas selector valve will have to be switched. Rotate the black gas selector valve (Fig. 4.1.6a) to point at the desired process gas. The black valve handle is shaped like an arrow, point the arrow in the direction of the gas you will use. The gases are labeled on the incoming tubing lines. (Fig. 4.1.6a) 4.1.8 The system is now ready to run your process. 4.2 Starting a Process 4.2.1 If the computer is powered OFF then turn ON the system computer by pressing the power button (Fig. 4.3.1a) on the front of the computer. (Fig. 4.3.1a) 7

4.2.2 Power up the main RTA system by pressing the green On button on the upper right front panel of the RTA system (Fig. 4.3.2a). The ON button should illuminate once pressed. (Fig. 4.3.2a) 4.2.3 Once the computer has finished booting up, double-click the JETFIRST icon (Fig. 4.3.3a) from the Windows XP desktop to start the RTA software. (Fig. 4.3.3a) 8

4.2.4 To select an existing recipe to run, select the Processing button (Fig. 4.3.4a) from the jipelec main page. **Note** If you need to create or edit a recipe before processing then proceed to Section 5.0 of this SOP. Once your process recipe is ready you may return to this step. (Fig. 4.3.4a) 4.2.5 If prompted for an Engineering password (Fig. 4.3.5a) proceed by entering nanofab as the password. (Fig. 4.3.5a) 9

4.2.6 Once the Processing option has been selected a recipe selection window will open. Highlight the recipe to download from the drop down menu (Fig. 4.3.6a). (Fig. 4.3.6a) 4.2.7 Select the Download button and begin the recipe download, this will take approx 5 seconds at which time a Download was successful dialog box will open (Fig. 4.3.7a), now select OK to proceed. (Fig. 4.3.7a) 4.2.8 Press the Start Processing button. A prompt will tell you to load your wafer into the oven. **Note** If you have not loaded your sample and you are unsure of how this is done proceed to Section 4.2 Loading a Sample if you need assistance. 4.2.9 Once your wafer or sample has been loaded properly select Ok to begin processing. 10

4.2.10 Your process will now begin and the Process screen will open. (Fig. 4.3.10a) This screen will remain open while your process is running and will show the system process parameters in real time. (Fig. 4.3.10a) 4.2.11 Once your process has completed a dialog box titled Process Saving will open (Fig. 4.3.11a) Locate your personal file folder in the selection box in the upper left hand corner and double click on it to open it. Now you may enter any comments or change the file name and then select the Save button. ***Note*** All runs MUST be saved, failure to do so will result in a loss of reservation privileges on this system. (Fig. 4.3.11a) 11

4.3 Loading a Sample 4.3.1 The software will prompt you to load your sample when a process is started, however you may load a sample at any time. 4.3.2 Begin loading your sample by turning the front cover locking handle CCW 90 degrees (Fig. 4.2.2a) and lifting the main process chamber lid. Do not force the handle to rotate, if the system determines the chamber temp is too high it will lock the handle for safety reasons. Wait a few minutes and try to rotate the handle again. (Fig. 4.2.2a) 4.3.3 If you are annealing a 4 wafer then position it centered directly on the quartz sample holder pins (Fig. 4.2.3a), with the polished side facing up. If you are annealing a smaller sample then you will have to sit it on top of a clean 4 silicon wafer, once again with the polished side facing up. The wafer and sample will then be carefully positioned on top of the quartz sample holder pins. If positioned properly the 4 wafer should be sitting level approximately ½ off the lower plate. (Fig. 4.2.3a) 12

4.3.4 (Note - If you are using pyrometer temp control in your recipe you may skip this step.) If your process will be run at atmospheric pressure using thermocouple temperature control in the recipe then you must ensure that the tip of the TC is contacting the center of the bottom of your 4 wafer (Fig. 4.2.4a). ***WARNING*** It is important that you ensure the TIP of the Thermocouple wire CONTACTS the backside of the 4 wafer. Failure to do so may cause an over temperature condition in the chamber destroying your sample and damaging the Jetfirst system. Temp Control TC TC contact area (Fig. 4.2.4a) 4.3.5 Once you have properly positioned the 4 wafer and thermocouple (if it is needed) you can close the process chamber lid and securely latch it by rotating the black handle 90 degrees CW. 13

4.4 Unloading a Sample 4.4.1 To begin unloading your sample, rotate the black handle on the process chamber cover 90 degrees CCW. If the handle is locked and will not rotate then the chamber is still above the safe temperature. Wait five minutes and then try to rotate the handle again. 4.4.2 Lift the chamber lid fully (Fig. 4.4.2a) until it stops, be careful to support the lid and make sure it does not fall back down under its own weight. Give your sample additional time to cool down if needed with the chamber lid open before attempting to unload. (Fig. 4.4.2a) 4.4.3 Remove your sample from the chamber and then close and latch the chamber lid. 4.5 System Shutdown 4.5.1 Turn OFF the system computer by selecting the Shutdown option in Windows XP or by momentarily pressing the computers front panel POWER button (Fig. 4.5.1a). (Fig. 4.5.1a) 14

4.5.2 Press the square red OFF button located on the upper right hand side (Fig. 4.5.2a) of the RTA system front panel. The illuminated green ON button should turn off at this time. (Fig. 4.5.2a) 4.5.3 At the rear of the RTA system turn the Argon / H2-N2 Forming gas selector valve (Fig. 4.5.3a) to its closed position, it should be pointing straight down when closed. (Fig. 4.5.3a) 15

4.5.4 Go to the service chase behind the system and close the main Argon cylinder valve by turning it fully CW until it stops (Fig. 4.5.4a). If the bottle supply pressure gauge on the right hand side is reading less than 200psi notify NanoFab staff at this time. (Fig. 4.5.4a) 4.5.5 In the service chase turn OFF the mechanical pump (Fig. 4.5.5a). (Fig. 4.5.5a) 4.5.6 If H2 N2 forming gas was used during processing notify Nanofab staff to turn off the forming gas supply valves. 4.5.7 The system is now secure. 16

5.0 Recipes 5.1 Recipe Rules 5.1.1 Basic recipe rules. Never exceed 1000 deg C for any period of time. You must follow the Temp Vs Time chart (Fig. 5.1). If you create a recipe you must use your name in the recipe title. You must use PYROMETER temp control when processing under vacuum conditions. The pyrometer can only control temperatures from 400C 1000C. Thermocouple temp control can ONLY be used with the chamber at atmospheric pressure. In other words, REDUCED PRESSURE PROCESSING IS NOT ALLOWED WHILE UNDER THERMOCOUPLE CONTROL. When controlling the temperature using POWER mode do not exceed 30% power request or overheating and system damage can occur. (Fig. 5.1) 17

5.2 Creating a New Recipe 5.2.1 **Note** It is much easier to edit an existing recipe to meet your requirements than to create a new one every time. Proceed to Section 5.3 to edit an existing recipe and save it with your own filename. 5.2.2 To begin creating a new recipe, select the Recipes button (Fig. 5.1.2a) from the main jipelec software interface menu. (Fig. 5.1.2a) 5.2.3 If prompted for an Engineering password (Fig. 5.1.3a) proceed by entering nanofab as the password. (Fig. 5.1.3a) 18

5.2.4 A box titled Recipes (Fig. 5.1.4a) will open. Now select the New button in the lower left hand corner. (Fig. 5.1.4a) 5.2.5 The first screen that opens will be the Recipe Heading screen. On this page you are required to fill in the 3 boxes labeled Filename, Pyrometer Calibration table and Thermocouple calibration table. All other information on this page is optional. The Pyrometer calibration table for every recipe should be HT150 and the Thermocouple calibration table should be StandardTC. The filename should have the users name as a portion of the title, this will be the actual recipe name. 19

5.2.6 Once you are finished filling in the information on the Recipe Heading screen select the Edit button. The screen that opens will be Step #1 of your new recipe. Fill in the pertinent information in this step then select the button titled Next Step. Below is the basic format of a complete recipe and Step 1 (Fig. 5.1.6a) of a recipe. Basic recipe step format. Step 1 Evacuate the chamber Step 2 Purge the chamber back to atmosphere Step 3 Ramp to process temp Step 4 Ramp to process temp 2 for multi-temp processes. Step 5 Ramp to low temp and cool for unloading. (Fig. 5.1.6a) 5.2.7 You can move forward or backward at any time during editing by pressing the buttons titled Next Step or Previous Step. 5.2.8 Once you have completed your recipe steps select the Save button. 5.2.9 It is recommended that you go back through your recipe steps and thoroughly inspect them for any errors before running the new recipe, be sure to click Save again after any changes. 5.2.10 To run your new recipe proceed to Section 4.3. 20

5.3 Editing an Existing Recipe 5.3.1 To begin editing an existing recipe, select the Recipes button (Fig. 5.2.1a) from the main Jipelec software interface menu. (Fig. 5.2.1a) 5.3.2 If prompted for an Engineering password (Fig. 5.2.2a) proceed by entering nanofab as the password. (Fig. 5.2.2a) 5.3.3 A box titled Recipes will open. Now scroll to the desired recipe in the upper right hand menu and highlight that recipe then select the Open button. 5.3.4 The next window that opens will be the Recipe Heading screen. If you wish to edit this recipe and save it with a new recipe name then enter the new name in the box titled Recipe name and then press the EDIT button. If you plan on keeping the existing recipe name do not change anything just press the EDIT button. 21

5.3.5 Once you press the EDIT button the next window which opens will be the first step in your edited recipe. You may begin making changes to the individual steps now. Press the Next Step or Previous Step buttons to navigate through the recipe. 5.3.6 When you have finished making changes to the recipe select the Save button. A prompt will notify you that saving was successful, select Ok. 5.3.7 Now select the Exit button, a prompt will open telling you to save your recipe changes before exiting. As long as you have saved your changes select Yes to exit the recipe edit screen. 5.4 Nanofab Standard Recipes 5.4.1 22