Thermal Shock Chamber TSE 11

Similar documents
Thermal Shock Chamber

Thermal Shock Chamber TSD 100

Thermal Shock Chamber

Vacuum Oven VAC LCV CAT.NO.E17196

Pressure Automated Calibration Equipment

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

Series Environmental Chambers

Drying ovens FD series Drying ovens with forced convection Leistungsmerkmale/Ausstattung:

Guideline No.M-05(201510) M-05 AIR COMPRESSOR. Issued date: 20 October China Classification Society

CO2 incubator with additional process controls

TH-1800-T TRX-700-CNG Converter

BUBBLER CONTROL SYSTEM

RPS900W Redundant Power Supply. Installation Guide.

SonoMeter 30 Energy Meters

Valve Proving System VDK 200 A S06*

BUBBLER CONTROL SYSTEM

CO 2 radial piston compressor (transcritical)

NEW: CO2 incubator with sterilizable sensor

MOYNO FLUID DETECTION CONTROL SERVICE MANUAL. Section: ACCESSORIES. Page: 1 of 8 Date: May 1, 1998 GENERAL

Pneumatic high-pressure controller Model CPC7000

NEW: CO2 incubator with sterilizable sensor

Valve Proving System VDK 200 A S02

Model EXAxt AV550G. Averaging Oxygen Analyzer

Simple Set. Pressure Independent Control Valves 2 Way 1/2-2

Automatic Valve Proving Control

WATER MADE EASY MARINE ENERGY MUNICIPAL INDUSTRIAL

Stirring Water Bath. Instruction Manual

CCT-7320/ROC-2313 Reverse Osmosis Controller

CO2 incubator with additional process controls

TECHNICAL DATA MAINTENANCE AIR COMPRESSOR MODEL G-1

Recirculating Coolers

973-SF 6 Analyzer. Precise and Stable SF 6 Gas Analyzer REFLECTING YOUR STANDARDS

GM Series Dual-Block Multi-Function Gas Control Valves

THE NEW SP SERIES MAXIMUM CAPACITY MINIMUM FOOTPRINT

LED 14W POLO BULKHEAD WITH MICROWAVE SENSOR

MEGAS 2.0. Gas analysis with direct C-Level Calculation and Bus-Connection. Data sheet

Ruskinn Hypoxia and Anoxia Workstations. innovation in incubation

Used with Dissolution Tester for Fraction and Flow Measurements

HumiSys HF High Flow RH Generator

High Pressure Breathing Air Compressors

PumpAgents.com - Click here for Pricing/Ordering Nominal psi (bar) Cut-In Cut-Out

OC Panel High Limit Aquastat Kit, Manual Reset p/n

SPECIFICATIONS ATTENTION

VERTICAL AIR COMPRESSORS

7250 Sys. Ruska Multi-Range Pressure Calibration System. GE Sensing & Inspection Technologies. Features. Applications

COSMO INSTRUMENTS CO., LTD.

Pneumatic high-pressure controller Model CPC7000

THE NEW SP SERIES MAXIMUM CAPACITY MINIMUM FOOTPRINT

PLEASE READ CAREFULLY BEFORE INSTALLING OR USING MEGA POOL SAVER MPS 1100

444C DUAL PERFORMANCE VALUE PACK

Mass Flow Meter (MFM) for Gases

HyDefinition HD4070. Plasma Arc Cutting / Marking System. Product Configuration Manual Revision

Mass Flow Controller (MFC) for Gases

Operating instructions Safety Rope Emergency Stop Switches ZB0052 / ZB0053 ZB0072 / ZB0073

Pressure switch Type BCP

SRL Series. Oil-less Scroll Air Compressors. Pharmaceutical. Research & Development. Food & Beverage. Chemical. Electronic

400C & 450C DUAL PERFORMANCE VALUE PACKS

3 GALLON, OILLESS PANCAKE COMPRESSOR INSTRUCTIONS. Item #31289

MP15 Jockey Pump Controller

Model PSI Compressor with 3-Gallon Air Tank 12VDC

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO

ALL-IN-ONE MINI THERMAL MASS FLOWMETER

GRUNDFOS DATA BOOKLET. Hydro Solo-E. Complete pressure boosting systems 50/60 Hz

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO

Plasma Cleaner. Yamato Scientific America. Contents. Innovating Science for Over 125 Years. Gas Plasma Dry Cleaner PDC200/210/510 PDC610G.

AE R1 February 2015

200 PSI FAST-FILL AIR SOURCE KIT

TEL/jlRE" Introduction. Display Features and Modes. Startup Procedure. Power-Up Procedure. Adjustment Modes

780S Ultra High Purity Series

Qi Litre Ultrasonic Cleaner

CO2 incubator with additional process controls

TransPort PT878GC Panametrics Portable Gas Ultrasonic Flowmeter. GE Sensing. Applications. Features

MiniMag. 1 of 8. The MiniMag scrubber s 2 recover drain are 80% larger than a 1.5, making the MiniMag scrubber s drain hose less likely to clog.

Operating Manual. Model 25200B/25202B Refrigerant Recovery Unit. (Not for use in automotive R-134a applications)

Pressure controls for hydro carbons, zone II applications, Type KPE

Accelerated Corrosion Test Chambers

Analogue and Digital Mass Flow Meters and Controllers for Gases MASS-STREAM

400H HARDMOUNT AIR COMPRESSOR KIT PART NO H HARDMOUNT AIR COMPRESSOR KIT PART NO

Design Features. General Description

100C Air Compressor Kit

200 PSI COMPRESSORS - MODEL NUMBERS

Digital Flow Switch. Series PFM7

DPC-30 DPC-100. Reference Manual

Information Sheet. About this information sheet. Floor and wall loadings. Attachment of process module to floor. PlasmaPro Estrelas100

CO 2. (R744) Service Station Presentation. Contents. Goals Basic functions Specification Recovery R477 Vacuum Charge Safety Other features Prototype

IMPORTANT SAFETY INSTRUCTIONS

Tightness controls TC 1 3 and TC 4

Flow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25

Flow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25

Safe Accurate Reliable. CWM-301 Anesthesia System

Columbus Instruments

Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units

628 Differential Pressure Decay Leak Tester

420C AIR COMPRESSOR KIT PART NO C AIR COMPRESSOR KIT PART NO

Autocalibration Systems For In Situ Oxygen Analyzers

Budget Range Operators Handbook

Features. Description

VACUUM REGULATORS CONTENTS

Part 1 General Information Part 2 Outdoor Units... 8

OC4000 USER'S GUIDE I O OXYGEN CONCENTRATOR FOR VETERINARY USE ONLY. by Supera Anesthesia Innovations GLOSSARY OF SYMBOLS. : ON (power switched on)

Transcription:

Established 1981 Advanced Test Equipment Rentals www.atecorp.com 8-44-ATEC (2832) Thermal Shock Chamber TSE 11 CAT.NO.E1133-T122

ESPEC offers a compact, but highly performant thermal shock chamber ideal for the requirements of test standards with small and low-volume specimen. Equipped with superior temperature recovery performance capable of answering the requirements of severe test specifications, this thermal shock model offers a wide test area in a compact, slim design. 1 *The paperless recorder and additional overheat protector are optional.

Characteristics A high performance compact package to meet severe test requirements. A temperature recovery time of less than 5 minutes is achieved in 2 zones ( 15 and 65 ) without auxiliary cooling By realizing a temperature recovery time of less than 5 minutes for the upstream air in the 2 zones ( 15 and 65 ), we have achieved performance equivalent to that of a large thermal shock chamber without having to use auxiliary cooling by means of liquid carbon dioxide, which was required in previous compact thermal shock chamber. Complies with MIL-STD-883H and other test standards This compact thermal shock chamber satisfies the temperature cycle test requirements of MIL-STD-883H and other test standard (see page 5). Smooth specimen transfer The "soft-move mode" is used to reduce vibration shock when specimens are moving between the hot and cold chambers. High-temperature exposure Examples of temperature uniformity Test conditions High temperature exposure 15 3 min. Low temperature exposure 65 3 min. Specimen Plastic molded IC 2kg Low-temperature exposure Temperature uniformity measurement method Thermocouples were embedded in 1 plastic molded ICs (16 pin DIPs), which were then placed on two levels in each of the corners and in the center of a specimen basket. Uniform temperature distribution across specimens High temperature uniformity performance ensures consistent stress on specimens. Within 1.5 Sensor temperature (Test area: upstream) Within 1. 2

Characteristics Color LCD interactive touch-screen system Operation and settings simplified by the use of a touch-screen LCD display (instructions displayed on-screen). At-aglance confirmation of test patterns, test area temperatures, temperature cycles, upstream / downstream control, and trend graphs display. Controller Test area Control panel Setting Interactive key input by touch panel Display TFT Color LCD RAM (selected entry): a maximum of 4 patterns can be entered Test patterns ROM (built-in): contains 1 test standard patterns Auxiliary functions Timer preset Program memory Test continuity selection Automatic power shut-off Overheat/ Overcool protection Programmed time display Upstream/ downstream sensor selection Test suspension Stable time control Test completion mode selection Quick exposure control Trend graph Power recovery mode Alarm history display Automatic defrost Sensor calibration Temperature recovery time setting RS-485 communication Large 1.9-liter-capacity test area Features a 1.9-liter test area, twice that of our previous model. The volume that can be processed is greatly increased, and a 21 297mm printed circuit board can be tested in the horizontal position. Test area anti-drop mechanism A braking system fitted to the drive mechanism prevents specimens from falling into the test area when the chamber stops operation. Other protection mechanisms are equipped to ensure that the specimen does not fall. Easy wiring access A cable port is provided on the right side to allow easy wiring of specimens for measurement during high and lowtemperature cycle tests. Comprehensive safety system A dual safety system automatically stops the test area drive mechanism if the door is left open, and automatically locks the door when the test area is in motion. Equipped with casters for mobility 3 Cable port (5mm, shown with cap installed)

Characteristics A whole range of environmentally-friendly features Reduced power consumption Reduced power consumption is an important issue for our customers. This compact thermal shock chamber employs number of measures such as the use of electronic expansion valve to regulate the refrigeration capacity control. Specifically aimed at energy savings. Required footprint (Installation space: 2.88 m 2 ) 6 Rear intake and ceiling exhaust Top view Unit: mm Minimum footprint Its slim design requires only 2.88m 2 installation space (31 ft 2 ). Ideal for narrow spaces in labs or factories. 225 15 Material labeling for easy recycling Plastic molded components are labeled and easily detachable to make recycling easier for future disposal of the equipment. 6 3 68 3 128 Paperless recorder (option) Built-in paperless recorders is available to record temperatures from various sources, such as test area temperature. Recording is possible on Compact Flash Card or via USB port. Paperless recorder (optional) 4

TEST STANDARD (TSE-11-A compliant) Test standard Exposure temperature Exposure time Temp. High temp. Ambient temp.* Low temp. High/ low temp. Ambient temp.* recovery time Number of cycles Test starting point MIL-STD-883H (Method No. 11.8) A B C D 1 85 15 125 15 15 15 2 55 1 65 1 more than 1 min. Specimen temp within 15 min. at worst condition Minimum 1 cycles Low or high temp. F 15 175 IEC 668-2-14 (JIS C 668-2-14) 7 2 85 2 1 2 125 2 155 2 175 2 2 2 5 3 1 3 25 3 4 3 55 3 65 3 3 hours 2 hours 1 hour.5 hour 3 hours if not specifi ed less than 1 sec. less than 1 of exposure time 5 cycles if not specifi ed Low temp. JASO D 1 1 85 2 75 3 12 4 Less than.2 kg 1 hour 15 min..2.8 kg 2 hours 15 min..8 1.5 kg 3 hours 15 min. More than 1.5 kg 4 hours 15 min. Short exposure is recommendable Upstream of specimen within 5 min. 6 cycles High temp. 6 2 65 2 7 2 75 2 8 2 85 2 9 2 95 2 1 2 3 5 3 1 3 15 3 2 3 25 3 3 3 35 3 4 3 45 3 5 3 3 hours 2 hours 1 hour.5 hour 3 hours if not specifi ed less than 1 sec. less than 1 of exposure time 5 or 1 cycles Low temp. The above specification tests include only those tests applicable to TSE-11-A. For further information, please contact us. * Ambient temperature at exposure temperature and exposure time represents the temperature and time when moving from hot chamber to cold chamber. 5

SPECIFICATIONS Model System Test area High temp. exposure range Low temp. exposure range Temperature fl uctuation *2 TSE-11-A 2-zone transition by vertical transfer of specimen 6 to 2 ( 14 to 392 ) 65 to ( 85 to 32 ).5 (.9 ) Performance *1 Construction Hot chamber Clod chamber Temp. recovery Pre-heat upper limit Temp. heat-up time *3 Pre-cool lower limit Temp. pull-down time *3 Recovery conditions Temp. recovery time Test area Heater System Compressor Refrigerant Condenser Cooler Air circulator Refrigeration unit Fittings Test area load resistance Specimen basket load capacity Inside dimensions (W H D) Test area capacity Outside dimensions (W H D) *4 Weight Allowable ambient conditions Power supply (Voltage fl uctuation: rating 1 ) 2 ( 392 ) Ambient temp. to 2 ( 392 ) within 3 min. 8 ( 112 ) Ambient temp. to 8 ( 112 ) within 9 min. 2 zones High temperature exposure: 15 ( 32 ), 3 min. Low temperature exposure: 65 ( 85 ), 3 min. Sensor position: Upstream Specimen: Plastic molded ICs 2 kg within 5 min. Shelf brackets on 2 levels of fi xed location Stripped wire heater Mechanical cascade refrigeration system Rotary 1.5 kw 2 R58A R44A Air-cooled condenser Plate fi n cooler, cold accumulator Sirocco fan Specimen power supply control terminal, integrating hour meter without reset, time signal (2), cable port 5 mm, (right side), casters with leveling feer (4), power cable 8 kg 2kg per basket (equally distributed load) 2V AC 3 3W 5/6Hz 32 148 23mm (12.6 5.8 9 inch) 1.9 L 68 1625 15mm (26.8 64 41.3 inch) approximately 39kg to 4 ( 32 to 14 ) 22V AC 3 3W 6Hz 38V AC 3 4W 5Hz 4/415V AC 3 4W 5Hz 4V AC *5 3 4W 5Hz Maximum load current 26A 25A 17A 17A 17A Exhaust heat quantity *6 17,585kJ/h *7 6dB or less *1 The performance values are under the conditions of a 23 ambient temperature, relative humidity of 65%rh, rated voltage, and no specimen. Heat up time and pull down time are those of single-unit operation of each chamber. *2 The performance values are based on IEC668-3-5:21, JTM K7:27. *3 Temperature heat-up/pull-down time account for performance of each temperature chamber. *4 Excluding protrusions. *5 Compliance with CE Marking. *6 At ambient temperature 23. *7 At 1m from front of chamber, 1.2m from floor. (ISO 1996-1:23 A-weighted sound pressure level) depending on environment DANGER Do not use specimens which are explosive or inflammable, or which contain such substances. To do so could be hazardous, as this may lead to fire or explosion. Do not place corrosive materials in the chamber. If corrosive substances or humidifying water is used, the life of the unit may be significantly shortened. Do not place life forms or substances that exceed allowable heat generation. CAUTION Be sure to read the user s manual before operation. 6

SAFETY DEVICES Leakage breaker (2, 22, 38, 4/ 415V AC) Circuit breaker (4V AC) Electrical compartment door switch Hot chamber overheat protection switch Cold chamber overheat protection switch Hot chamber overheat protector (Controller) Cold chamber overheat / overcool protectors (Controller) Test area overheat and overcool protectors (Built-in controller) Test area overheat / overcool protectors Refrigerator high pressure switch Thermal relay for compressor Temperature switch for compressor Temperature switch for air circulator Thermal relay for air circulator Motor inverter Motor reverse prevention relay Hot chamber door switch Cold chamber door switch Test area hold Door lock mechanisms Fuse Specimen power supply control terminal OPTIONS Paperless recorder Records temperature of each section such as the temperature inside the chamber. Number of inputs: PL1S: 1 (5 more channels can be turned ON) Data saving cycle: 1 sec PL3S: 3 (3 more channels can be turned ON) Data saving cycle: 1 sec PL3L: 3 (3 more channels can be turned ON) Data saving cycle: 5 sec Temperature range: 1 to 22 External memory: CF memory card port (Includes a 256MB CF card) Languag: ENG, JPN can be changed ACCESSORIES Specimen basket (18-8 Cr-Ni stainless steel, 5 mesh metal basket) W32 H35 D23mm Load capacity: 2kg (equally distributed) 2 Cartridge fuse (5 A) 1 Cable port rubber plug 2 Wirefisher 1 User's manual (CD-R, booklet) 1 set Temperature recorder (digital display) Temperature range: 1 to 22 Effective recording chart width: 1mm RK-61: 1pen RK-63: 3 pens RK-64: 6 dots Recorder wiring Preparation of a power cable, temperature sensor, and conductor grounding wire for additional installation in the future. 7

OPTIONS Terminal for recorder To output temperature values from the test area, hot chamber, cold chamber. Total cycle counter Indicates cycle counts. Display range: 1 to 99999999 (with reset function) Specimen basket Equivalent to standard accessory. Material: stainless steel (5 mesh) Specimen power supply control terminal Time signal Thermocouple External alarm terminal (option) Attached to specimens to measure specimen temperature. 2m 4m 6m T JIS C 162 with ball attached Auxiliary cooling injector (LCO2) Used to reduce the temperature recovery time of low temperature exposure by injecting liquefied carbon dioxide at the beginning of exposure. Auxiliary cooling injector (LN2) Used to reduce the temperature recovery time of low temperature exposure by injecting liquefied nitrogen at the beginning of exposure. Additional overheat protector Additional preventive measures can be taken for excessive temperature rise in the chamber, in addition to the standard equipped overheat protectors. External alarm terminal If the safety device of the chamber is activated, the external alarm terminal will notify it to a remote point. Emergency stop pushbutton Stops the chamber immediately. Cable port rubber plug Prevents air leakage from the cable port. Anchoring fixtures Used to bolt the chamber to the floor. Power cable Used to connect to the primary power source. 5m 1m Color specification Chamber can be painted to any desired color. (a color sample is required) Interface Computer interface GPIB Serial interface RS 232C *Select one, instead of standard RS 485. Communication cable RS 485 GPIB RS 232C 5m/ 1m/ 3m 2m/ 4m 1.5m/ 3m/ 6m Some photographs listed in this catalog contain Japanese display. 8

http://www.espec.co.jp/english Head Office 3-5-6, Tenjinbashi, Kita-ku, Osaka 53-855, Japan Tel : 81-6-6358-4741 Fax : 81-6-6358-55 ESPEC NORTH AMERICA, INC. Tel : 1-616-896-61 Fax : 1-616-896-615 ESPEC EUROPE GmbH Tel : 49-89-1893-963 Fax : 49-89-1893-96379 ESPEC (CHINA) LIMITED Tel : 852-262-83 Fax : 852-262-788 ESPEC ENVIRONMENTAL EQUIPMENT (SHANGHAI) CO., LTD. Head Office Tel : 86-21-5136677 Fax : 86-21-63372237 BEIJING Branch Tel : 86-1-6462725 Fax : 86-1-6462736 TIANJIN Branch Tel : 86-22-2621366 Fax : 86-22-26282186 GUANGZHOU Branch Tel : 86-2-83317826 Fax : 86-2-83317825 SHENZHEN Branch Tel : 86-755-83674422 Fax : 86-755-83674228 SUZHOU Branch Tel : 86-512-682889 Fax : 86-512-682886 ESPEC TEST TECHNOLOGY (SHANGHAI) CO., LTD. Tel : 86-21-687988 Fax : 86-21-6879888 ESPEC SOUTH EAST ASIA SDN.BHD. Tel : 6-3-8945-1377 Fax : 6-3-8945-1287 Quality Management System Assessed and Registered ESPEC CORP. has been assessed by and registered in the Quality Management System based on the International Standard ISO 91:28 (JIS Q 91:28) through the Japanese Standards Association (JSA). Registration : ESPEC CORP. (Overseas subsidiaries not included) Environmental Management System Assessed and Registered ESPEC CORP. Specifications are subject to change without notice due to design improvements. TW2E24C3 (The contents of this catalog is as of February, 212.) Corporate names and trade names mentioned in this catalog are trademarks or registered trademarks.