LUMILUX T5 HO CONSTANT

Similar documents
QTi DALI/DIM / QTi GII / QTP5

QTi DALI/DIM / QTi GII / QTP5

QTi DALI/DIM / QTi GII / QTP5

QT-FIT8 2X58-70/ VS20

DULUX L LUMILUX DE LUXE

QT-FIT8 2X58-70/ VS20

DULUX L LUMILUX IMPROVED LIFETIME & SYSTEM GUARANTEE. DULUX L LUMILUX & QUICKTRONIC TECHNICAL INFORMATION 1.

POWERBALL HCI -TC. Technical Information. POWERBALL HCI -TC for enclosed luminaires.

POWERBALL HCI -T. Technical Information. POWERBALL HCI -T for enclosed luminaires.

HCI-TT 250 W/942 NDL PB

POWERBALL HCI -T. Technical Information. POWERBALL HCI -T for enclosed fixtures.

HCI-T 70 W/942 NDL PB

HCI-T 70 W/942 NDL PB

POWERBALL HCI-T. Product family datasheet. Metal halide lamps with ceramic technology for enclosed luminaires

POWERBALL HCI-T. Product family datasheet. Metal halide lamps with ceramic technology for enclosed luminaires

Residential Road_Lighting Class S5

POWERSTAR HQI -TM 600 and 1000W POWERBALL HCI -TM 250 and 400W

PrevaLED Linear Slim 2

LED Modules. Fortimo LED Line High Flux PR. 2ft 4000lm 1R NA

T5 Retail Sales. 2011, September 8 data subject to change

CURION 185 FIXED Colour White = MW Matte White RAL 9016 Colour Black = BL Matte Black RAL 9005 Beam Angle 80 EN60598 / EN62031 / EN62471 >25 >25.

The AR111 LED is ideal solution for spot lighting in shops

LED Lightsource-R High Bay - EU

LED Lightsource-R High Bay - EU

Photometric Test Report

SPORTS: Single Tennis court 24x11m for class III

SPORTS: Single Tennis court 24x11m for class III

Experience bright and vivid colors

LED Down Light (8 ) Dimension:

EX-RECESSED CEILING LIGHT FITTINGS

CONTOUR SPECIFICATION

Less power great performances

Technical data: SCHUCH quality - Your advantage:

Technical data: SCHUCH quality - Your advantage:

DRIVER VOLTAGE DRIVER TYPE. DM v Low Voltage Dimming (10% - 100%) (Standard) LV - Line Voltage Dimming *Specify Voltage (120v or 277v)

DRIVER VOLTAGE DRIVER TYPE. DM v Low Voltage Dimming (10% - 100%) (Standard) LV - Line Voltage Dimming *Specify Voltage (120v or 277v)

Light Engines. Data Sheets. Nix II Series. Oberon II Series. Pluto II Series. Titan II Series. Mercury II Series. Aries II Series.

HALODIUM II. Product family datasheet. Outdoor flood- and spotlights. Areas of application _ Facades and monuments _ Parks

LED Tips & Tricks. PO Box 1949, Nelson 7040, New Zealand. Head Office, 53C Bolt Road, Nelson 7011, New Zealand

TEST REPORT. ACCORDING TO IES LM For. Samsung Electronics Co., LTD. 1,Samsung-Ro,Giheung-Gu,Yongin-City,Gyeonggi-Do 17113, Korea

LED 14W POLO BULKHEAD WITH MICROWAVE SENSOR

LED lighting systems

code: NEWS _EN s/p LED 2016 NEWS 02 -EN

IESNA LM MEASURING LUMEN MAINTENANCE OF LED LIGHT SOURCES. For. EiKO Global, LLC W 84th Street, Shawnee, KS 66227

Floodlight LED. Series Operating instructions EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN

User manual. PCA EXCEL one4all with corridorfunction PCA T5 ECO lp with corridorfunction TE one4all with corridorfunction

Stance LED Pendant Indirect/Direct

Datasheet. Inground. The Inground series is an LED luminaire for in-ground installation for a variety of architectural applications.

FL200 Monochromatic Architectural Spot and Floodlight

Crown Candle 30/40 Equivalent Non-dimmable / Dimmable

CEAG HandRail LED. Hand rail mounted Luminaire for all applications

Mirror with Socket

Floodlight LED. Series Operating instructions EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN

RobLight FL 1500 B-2. User manual. Applies to: RobLight A/S Nordhavnsvej 1A DK Frederikshavn. Phone:

POWERED BY IP66 IK08 LM-80 LED URBAN LIGHT. LED Urban Light

PORTABLE WORK LIGHT MODEL NO: CL6FS OPERATION INSTRUCTIONS PART NO: GC0315

IESNA LM MEASURING LUMEN MAINTENANCE OF LED LIGHT SOURCES MEASUREMENT AND TEST REPORT. For

ASM. Asynchronous Spindle Motors. SEM Limited Faraday Way Orpington, Kent BR5 3QT United Kingdom

COMFORT LED. The new TECO range

LM LUMEN MAINTENANCE TEST REPORT

FENCER Under Cabinet LED Light Fixture

IESNA LM MEASURING LUMEN MAINTENANCE OF LED LIGHT SOURCES MEASUREMENT AND TEST REPORT. For

LAMP 339-9SUGSURSUBC/S1174

A smooth design solution for a seamless look

Living. Furniture Set * 033*,131*,318*,483*, , furniture set with LED

Table of Contents. Version 5.1. Mounting Hardware 9-10 Aluminum 9 Plastic 9 Plastic & Aluminum 10

A smooth design solution for a seamless look

COMFORT LED. The new TECO range

IESNA LM MEASURING LUMEN MAINTENANCE OF LED LIGHT SOURCES MEASUREMENT AND TEST REPORT. For

Instruction and Maintenance Manual

LIMBA SUSPENDED LUMINAIRES

Verdi G-Series Family

SDGOG SDGLK. Device mount with indirect component

Mistral LED. Exterior Amenity Luminaires.

EALP05RDBRA0 LAMP. Features. Description. Applications. Choice of various viewing angles. Available on tape and reel. Reliable and robust

1224SUBC/C470/S400-A4

2/2- and 3/2-way Rocker Solenoid Valve - bistable (impulse) version

Further technical information is available on

Cualiti Photo Studio

SRL Series. Oil-less Scroll Air Compressors. Pharmaceutical. Research & Development. Food & Beverage. Chemical. Electronic

METEOR LSR36500 LIGHTING UNDERWATER POOL LIGHT. Operating Instructions

liniled Handrail liniled Handrail Number of LEDs

ChromaLit Extruded Linear

LAMP 336SURSYGWS530-A3

TUV Low Pressure Mercury

LAMP SUGC/S400-A5

Cualiti Photo Studio

A60 A65 YEAR MODEL. 100 mm VT w SKU: K WARM WHITE SKU: K DAY WHITE SKU: K WHITE. 37 mm MODEL SHAPE A60 VT

Series AM3T-VZ 3 Watt DC-DC Converter

BSM SEAL. Kitchens, bathrooms, saunas, porches, balconies and similar high humidity environments. IP65 SMALL RECESSED DOWNLIGHTS

204-10SDRD/S530-A3 LAMP. Features. Description. Applications. Revision 1. LifecyclePhase: Expired Period: Forever. Choice of various viewing angles

Examination lamps OBSERVA ALFALED A06 L88 ALFA

(AS AT 31 st MARCH, 2002)

LED FLOOD LIGHTING SPORTS LIGHTING CASE STUDY. Yankee Stadium. New York USA

Sloped Ceiling Recessed Fixtures. LED Housings and LED Inserts Medium Base Housings and Trims

333-2SURC/H3/S530-A4 LAMP. Features. Description. Applications. 1 Ver.:2 Release Date:12/13/2016 狀態 :Approved( 正式發行 )

Leveraging Lighting - Increasing Your Bottom Line while Enlightening the Environment

E2K-L. Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid. Liquid Level Sensor. Ordering Information

Instruction and Maintenance Manual

Safety. Operating instructions Solenoid valve for gas VG 6 VG 15/10 DANGER. Contents WARNING CAUTION. Changes to edition 09.14

Transcription:

osram.com LUMILUX Constant Light output over a wider temperature range LUMILUX QTi DALI/DIM / QTi GII / QTP5 TECHNICAL INFORMATION 01

Benefits Impressive luminous flux at high and low ambient temperature Stable and suitable for luminaires that contain special material, outdoor applications or with low heat insulation. Compatible and one to one replacement to existing T5 lamps Very good luminous flux maintenance throughout the life of the lamp Product Features Luminous flux greater than 90% in an ambient temperature range of +50 C to +70 C (The 49W : 20 C to 80 C) High efficacy Long average life time: up to 24,000 h (with QUICKTRONIC ) Good color rendering index 1B (Ra: 80 89) Dimmable with appropriate ECG Up to 15% more Luminaire Efficiency in comparison to current standard T5 lamps Available colors: Cool Daylight (865), Cool White (840), Warm White (830) Dimensions Description Base Length (l1) max Length (l2) min Length (l2) max Length (l3) max LUMILUX 24 W G5 549 553.7 556.1 563.2 17 LUMILUX 39 W G5 849 853.7 856.1 863.2 17 LUMILUX 49 W G5 1449 1453.7 1456.1 1463.2 17 LUMILUX 54 W G5 1149 1153.7 1153.1 1163.2 17 LUMILUX 80 W G5 1449 1453.7 1456.1 1463.2 17 Tube Diameter (d) max TECHNICAL INFORMATION 02

Electrical Data 1 LUMILUX Lamp Voltage in HF 2 mode rated [V] Lamp Current in HF mode rated [ma] 24 W 77 295 440 39 W 118 325 440 49 W 195 255 330 54 W 120 455 720 80 W 152 530 765 Pre-heat current rated [ma] Photometrical Data 3 LUMILUX Light Color LUMILUX Color Rendering Index (CRI), Ra Target Color Coordinate X Target Color Coordinate Y Color Temperature [K] Nominal Luminous Flux 24 W 830 Warm White 80 89 0.440 0.403 3000 1900 2000 24 W 840 Cool White 80 89 0.380 0.380 4000 1900 2000 24 W 865 Cool Daylight 80 89 0.313 0.337 6500 1840 1900 39 W 830 Warm White 80 89 0.440 0.403 3000 3400 3500 39 W 840 Cool White 80 89 0.380 0.380 4000 3400 3500 39 W 865 Cool Daylight 80 89 0.313 0.337 6500 3225 3325 49 W 830 Warm White 80 89 0.440 0.403 3000 4450 4900 49 W 840 Cool White 80 89 0.380 0.380 4000 4450 4900 49 W 865 Cool Daylight 80 89 0.313 0.337 6500 4235 4600 54 W 830 Warm White 80 89 0.440 0.403 3000 4850 5000 54 W 840 Cool White 80 89 0.380 0.380 4000 4850 5000 54 W 865 Cool Daylight 80 89 0.313 0.337 6500 4610 4750 80 W 830 Warm White 80 89 0.440 0.403 3000 6800 7000 80 W 840 Cool White 80 89 0.380 0.380 4000 6800 7000 80 W 865 Cool Daylight 80 89 0.313 0.337 6500 6450 6650 [lm] Max. Luminous Flux [lm] 1 According to IEC 60081 (measurement with reference control gear) 2 High Frequency 3 Measurement in accordance with EN 60081, annex C and the relevant annex on rated colour characteristics in IEC 60081. TECHNICAL INFORMATION 03

Relative Luminous Flux / Ambient Temperature For more detailed information please refer to our technical guide for Fluorescent Lamps. Free download at www.osram.com TECHNICAL INFORMATION 04

Lifetime 4 B50 7 Service life time 8 ECG 5 (IEC 60929) preheat IEC 60081 switching cycle 6 24,000 h 19,000 h LLMF 9 20.000 h 0.89 LLMF 16.000 h 0.90 LLMF 12.000 h 0.90 LLMF 8.000 h 0.90 LLMF 6.000 h 0.91 LLMF 4.000 h 0.92 LLMF 2.000 h 0.95 LSF 10 20.000 h 0.85 LSF 16.000 h 0.97 LSF 12.000 h 0.99 LSF 8.000 h 0.99 LSF 6.000 h 0.99 LSF 4.000 h 0.99 LSF 2.000 h 0.99 4 Measurement in accordance with EN 60081, annex C. 5 Electronic Control Gear 6 Switching cycle 165 min. on, 15 min. off (according to IEC 60081) 7 Average rated lamp life (B50) is the average value of the life time for an entity of lamps operated under standardized conditions until 50% failure. In other words, this is the operation time at which, for a standardized 3-hour switching cycle (165 minutes on / 15 minutes off (according to IEC)), 50% of a sample population of lamps have failed. 8 Service life time is the mathematical life time (maintenance multiplied with the % of failed lamps e.g. B10) for lamps in an installation after which the installation luminous flux (100 h value) decreased with 20 % (decrease in luminous flux and failed lamps) for indoor lighting. 9 Lamp Lumen Maintenance Factor (lamp luminous flux in %): Ratio of the luminous flux of a specific quantity of lamps at a defined number of hours of operation to their luminous flux at 100 h 10 Lamp Survival Factor (lamp survival in %): Ratio of the number of electrically intact lamps to the total number of lamps TECHNICAL INFORMATION 05

Energy labelling 11 Description Energy efficiency class Weighted energy consumption E C [kwh/1000h] LUMILUX 24W/830 A+ 25 LUMILUX 24W/840 A+ 25 LUMILUX 24W/865 A+ 25 LUMILUX 39W/830 A+ 42 LUMILUX 39W/840 A+ 42 LUMILUX 39W/865 A 42 LUMILUX 49W/830 A+ 55 LUMILUX 49W/840 A+ 55 LUMILUX 49W/865 A+ 55 LUMILUX 54W/830 A+ 60 LUMILUX 54W/840 A+ 60 LUMILUX 54W/865 A 60 LUMILUX 80W/830 A+ 88 LUMILUX 80W/840 A+ 88 LUMILUX 80W/865 A+ 88 11 According to Regulation (EU) No 874/2012 of July 12, 2012 TECHNICAL INFORMATION 06

Logistic Data Description EAN 10 EAN 40 Packaging Unit LUMILUX 24W/830 4008321074911 4008321075420 20 LUMILUX 24W/840 4008321075451 4008321075468 20 LUMILUX 24W/865 4008321075475 4008321075482 20 LUMILUX 39W/830 4008321075512 4008321075529 20 LUMILUX 39W/840 4008321075550 4008321075567 20 LUMILUX 39W/865 4008321075574 4008321075581 20 LUMILUX 49W/830 4008321958761 4008321958730 20 LUMILUX 49W/840 4008321958778 4008321958747 20 LUMILUX 49W/865 4008321958785 4008321958754 20 LUMILUX 54W/830 4008321075611 4008321075628 20 LUMILUX 54W/840 4008321075659 4008321075666 20 LUMILUX 54W/865 4008321075673 4008321075680 20 LUMILUX 80W/830 4008321075819 4008321075826 20 LUMILUX 80W/840 4008321080042 4008321080059 20 LUMILUX 80W/865 4008321080066 4008321080073 20 TECHNICAL INFORMATION 07

Lamp/ECG System combination Lamp ECG EAN 10 ECG Luminous Flux [lm] @25 C LUMILUX 24 W LUMILUX 39 W System Power [W] IN [A] Power Factor ECG [λ] System Luminous Efficacy [lm/w] Length Width Height Distance between holes QTi DALI 1x14/24/220-240 DIM 4050300870380 1900 25.3 0.11 0.98 79 360 30 21 350-20 +50 QTi DALI 2x14/24/220-240 DIM 4050300870861 3800 49.3 0.22 0.98 77 423 30 21 415 +10 +50 QTi DALI 3x14/24/220-240 DIM 4008321069955 5700 73.4 0.32 0.99 78 360 40 21 350-20 +50 QTi DALI 4x14/24/220-240 DIM 4008321070036 7600 97.6 0.43 0.99 78 360 40 21 350 +10 +50 QTi 1x14/24/220-240 DIM 4050300870922 1900 26 0.11 0.98 79 360 30 21 350 +10 +50 QTi 2x14/24/220-240 DIM 4050300870946 3800 50 0.22 0.96 76 423 30 21 415 +10 +50 QTi 3x14/24/220-240 DIM 4008321069719 5700 74 0.32 0.99 77 360 40 21 350 +10 +50 QTi 4x14/24/220-240 DIM 4008321069993 7600 98 0.43 0.99 78 360 40 21 350 +10 +50 QTi 1x14/24/21/39 GII 4008321383334 1900 26 0.12 0.96 79 360 30 21 350 +10 +50 QTi 2x14/24/21/39 GII 4008321383396 3800 50 0.23 0.96 76 360 30 21 350 +10 +50 QTP5 1x24-39 4008321329110 1900 26 0.12 0.95 79 280 30 21 270-20 +50 QTP5 2x24-39 4008321329417 3800 49 0.23 0.95 78 360 30 21 350-20 +50 QTP-M 1x26-42 4008321329134 1900 25 0.12 0.95 79 103 67 31 110-20 +50 QTP-M 2x26-32 4008321329158 3800 49 0.23 0.97 78 123 79 33 129.5-20 +50 QT-M 2x26-42/220-240 S 4008321110022 3800 54 0.23 0.97 70 123 79 33 129.5-20 +50 QTi DALI 1x21/39/220-240 DIM 4050300870366 3400 41.8 0.19 0.98 81 360 30 21 350-20 +50 QTi DALI 2x21/39/220-240 DIM 4050300870489 6800 82 0.36 0.98 83 423 30 21 415 +10 +50 QTi 1x21/39/220-240 DIM 4050300870564 3400 41.8 0.18 0.98 81 360 30 21 350 +10 +50 QTi 2x21/39/220-240 DIM 4050300870694 6800 82 0.36 0.96 83 423 30 21 415 +10 +50 QTi 1x14/24/21/39 GII 4008321383334 3300 41 0.18 0.98 80 360 30 21 350-20 +50 QTi 2x14/24/21/39 GII 4008321383396 6600 81 0.36 0.98 81 360 30 21 350 +10 +50 QTP5 1x24-39 4008321329110 3300 41 0.18 0.98 80 280 30 21 270-20 +50 QTP5 2x24-39 4008321329417 6600 82 0.36 0.98 80 360 30 21 350-20 +50 T a [ C] TECHNICAL INFORMATION 08

QTP-M 1x26-42 4008321329134 3300 41 0.18 0.97 80 103 67 31 110-20 +50 Lamp ECG EAN 10 ECG Luminous System IN Power Length Width Height T a [ C] Flux [lm] @25 C Power [W] [A] Factor ECG LUMILUX 49 W LUMILUX 54 W System Luminous Efficacy [lm/w] Distance between holes QTi DALI 1x35/49/80/220-240 DIM 4050300870809 4450 53.4 0.24 0.98 83 360 30 21 350 +10 +50 QTi DALI 2x35/49/220-240 DIM 4050300870465 8900 103.6 0.45 0.99 86 423 30 21 415 +10 +50 QTi DALI 2x35/49/80/220-240 DIM 4050300870441 8900 101 0.46 0.99 88 423 30 21 415 +10 +50 QTi 1x35/49/80/220-240 DIM 4050300870540 4450 53.4 0.24 0.98 83 360 30 21 350 +10 +50 QTi 2x35/49/80/220-240 DIM 4050300870984 8900 103 0.46 0.97 86 423 30 21 415 +10 +50 QTi 2x35/49/220-240 DIM 4050300870670 8900 103.6 0.45 0.97 86 423 30 21 415 +10 +50 QTi 1x28/54/35/49 GII 4008321383358 4450 53 0.24 0.97 84 360 30 21 350-20 +50 QTi 2x28/54/35/49 GII 4008321383419 8900 105 0.46 0.98 85 360 30 21 350-20 +50 QTi 1x35/49/80 GII 4008321383372 4450 53 0.24 0.97 84 360 30 21 350-20 +50 QTi 2x35/49/80/220-240 4008321174291 8900 104 0.46 0.97 86 425 30 21 415-20 +50 QTP5 1x49 4008321329370 4450 53 0.24 0.95 84 280 30 21 270-20 +50 QTP5 2x49 4008321329431 8900 106 0.49 0.99 84 360 30 21 350-20 +50 QTi DALI 1x28/54/220-240 DIM 4050300870809 4850 58.8 0.26 0.99 82 360 30 21 350 +10 +50 QTi DALI 2x28/54/220-240 DIM 4050300870502 9700 115 0.26 0.97 84 423 30 21 415-20 +50 QTi 1x28/54/220-240 DIM 4050300870588 4850 58.8 0.51 0.98 82 360 30 21 350 +10 +50 QTi 2x28/54/220-240 DIM 4050300870717 9700 115 0.26 0.99 84 423 30 21 415 +10 +50 QTi 1x28/54/35/49 GII 4008321383358 4850 58 0.51 0.98 84 360 30 21 350-20 +50 QTi 2x28/54/35/49 GII 4008321383419 9700 115 0.51 0.99 84 360 30 21 350 +10 +50 QTP5 1x54 4008321329394 4850 59 0.26 0.98 82 280 30 21 270-20 +50 QTP5 2x54 4008321329097 9700 115 0.50 0.99 84 360 30 21 350-20 +50 TECHNICAL INFORMATION 09

Lamp ECG EAN 10 ECG Luminous Flux @25 C [lm] LUMILUX 80 W System Power [W] IN [A] Power Factor ECG System Luminous Efficacy [lm/w] Length Width Height Distance between holes QTi DALI 1x35/49/80/220-240 DIM 4050300870809 6800 88.1 0.76 0.98 77 360 30 21 350-20 +50 QTi DALI 2x35/49/80/220-240 DIM 4050300870441 13600 165 0.38 0.98 82 423 30 21 415-20 +50 QTi 1x35/49/80/220-240 DIM 4050300870540 6800 88.1 0.74 0.99 77 360 30 21 350-20 +50 QTi 2x35/49/80/220-240 DIM 4050300870984 13600 165 0.39 0.99 82 423 30 21 415 +10 +50 QTi 1x35/49/80 GII 4008321383372 6800 85 0.39 0.99 80 360 30 21 350 +10 +50 QTi 2x35/49/80/220-240 4008321174291 13600 165 0.74 0.99 82 425 30 21 415 +10 +50 QTP5 1x80 4008321329059 6800 86 0.74 0.99 79 360 30 21 415 +10 +50 QT-FQ 2x80 4050300825564 13600 175 0.38 0.98 78 423 30 21 415-20 +50 T a [ C] For more information on ECG refer to http://www.osram.com/ecg For more information on System Guarantee refer to http://www.osram.com/guarantee In case of lamp breakage: www.osram.com/brokenlamp For more information technical Information see Technical guide. Free download at www.osram.com TECHNICAL INFORMATION 10