Vitrex Steriheel Baby Sterile Cutting Safety lancet

Similar documents
STANDARD OPERATING PROCEDURE

COMFORT. Complete Selection of Safety Lancets For all your point-of-care blood sampling needs

COLLECTION OF BLOOD. Types of patients

PERFORMANCE OF A FINGERSTICK

Lancets Recommended by PTS, Inc.

Title of Manual: Specimen Collection Document Number: GPA.SPC.45.0

Diacan and Diacan S. The safe and gentle vascular access for dialysis

EXERCISE 4: MICROCOLLECTION AND HEMATOCRITS. Hematocrit Skills: 5 points Capillary Puncture Skills: 26 points

REB SOP 02 Page 1 of 6. Finger Prick Blood Sampling. Effective Date April Approved by REB April Version Number 1 A.

FREQUENTLY ASKED QUESTIONS

Safety Huber Needles

User manual STARLOCK. Careways International - Innovation Quality Performance

Training Device Instructions

The Butterfly. Steep Trendelenburg Gel Bean Bag Positioner USE & CARE GUIDELINES DAVID SCOTT COMPANY

EXERCISE 8: BLEEDING TIME

BASIC KNOWLEDGE OF LABORATORY FIRST AID

PREPARATION AND SELF-ADMINISTRATION INSTRUCTIONS FOR PATIENTS

PREPARATION AND SELF-ADMINISTRATION INSTRUCTIONS FOR PATIENTS

HemoCue Hb Procedure Template

DIAGNOSTIC CARDIOLOGY

RECOMBINATE. [Antihemophilic Factor (Recombinant)] (For intravenous use only)

Patients Guide for Self Administering Intravenous Antibiotics General points

Sharps The Safe Use and Handling of - Safe System of Work

Tourniquet System. Ideal for single or bi-lateral orthopaedic surgery and pain management

Tourniquet System. Ideal for single or bi-lateral orthopaedic surgery and pain management. AT4 Tourniquet System. Introduction.

limbsandthings.com Advanced Venepuncture Arm User Guide For more skills training products visit Limbs & Things Ltd.

DONOR TM Pre-Evacuated Post-Operative Autologous Blood Reinfusion System

BRIGHTNESS MEDICAL Disposable Stapler

AR251/AR251-B. Venepuncture and Infusion Arm. Instruction Manual

VENIPUNCTURE MODULE 5: THE VENIPUNCTURE PROCEDURE

Newborn Nursing Skills and ALS Simulator LF01400U Instruction Manual

NOTES PATIENT DETAILS

HemoCue Training and Education Program. Capillary Sampling. Hemoglobin. USPRO1 Rev 1 3/03. Training and Education Program 2003 HemoCue, Inc.

Venepuncture. Clinical Skills. Venepuncture. Dr Brian Jenkins (Clinical Skills Lead) Sian Williams (Clinical Skills Manager)

Specimen Collection. Lead Screen Filter Paper Testing Dried Blood Spots (DBS) Laboratory Services February 2017

HEALTH SERVICES CODE A.6 CATEGORY: RN - SNP

Monosed ESR Non-Vacuum Tube USER S MANUAL

R S A B C CPR. Basic Life Support Flow Chart Check for danger. Check Response. Send for Help. Check Airway. Check for Breathing.

Unblocking the MicroSprayer Aerosolizer Model IA-1C With the High Pressure Reverse Cleaning Adapter. Instructions for Use

ROHO QUADTRO SELECT CUSHION ADJUSTMENT INSTRUCTIONS

Nancy Neal Elementary PRE-KINDERGARTEN SCHOOL SUPPLY LIST

Mounting the RoboFocus RF-3 Unit on the LX-200/400 MicroFocuser

Hemorrhoid Multiple Band Ligator Set Instructions for Use

Procedure 85 Attaching The Humidifier To The Oxygen Flow Meter Or Regulator. Procedure 86 Administering Oxygen Through A Nasal Cannula

Endotracheal Tubes - VentiSeal (High Volume Low Pressure)

Aseptic Techniques. Techniques for Sterile Compounding. Pharmacy Technician Training Systems Passassured, LLC

HUNTERS HELP TECHNOLOGIES

Inflatable penile implant 3-pieces inflatable penile implant with hydrophilic coating and One Touch Release technology.

Le Maitre Ltd. Co2 propelled Electric Air Cannon Instructions. & Loading instructions for Chinese Confetti, Streamers and Glitter

Virginia Game Fish Tagging Program Please Report Tagged Fish Call

Critical Disposables. Non-Sterile Angiographic Accessories. for Medical Device Manufacturers & Kit Packers

Acting in an Emergency

QNUK Level 3 Award in Emergency Paediatric first aid (QCF) Infant/Child CPR practical observation form

MyoSure Tissue Removal System. For you and your patients.

Passing a Nasogastric Tube. Information for Parents and Carers

Soft Tissue Injuries

Lab 1. Instrumentation Familiarity: Using Micropipetters and Serological Pipettes

Magic Carbo CMV1.3. Carboxytherapy Equipment. User Manual

Bleeding: Chapter 22 page 650

'First Aid' Results For JOE BLOGGS. First Aid. Summary

Assembly, Fitting, Care & Maintenance

Venepuncture. Clinical Skills. Venepuncture. Next

MIC *, MIC-KEY * GASTRIC-JEJUNAL (GJ) FEEDING TUBE PATIENT USE & CARE GUIDE

TEV-TROPIN [somatropin (rdna origin) for injection] 5 mg & 10 mg

1500 Follow Spot Yoke

Syringe, Distribution Valve and Infusion Pump Removal/Replacement ATTENTION SYRINGE REPLACEMENT

A designated area will have been assigned for all blood specimens to be taken. All blood should then be taken in that area only.

User instruction Trellchem Bayonet Ring System mark III with locking pin

Varithena Delivery System Instructions for Use INSTRUCTIONS FOR USE Please read the Product Monograph before using the product.

Ultrasound Guided Thoracentesis Simulator Strap-on Type

Ultrasound Guided Thoracentesis Simulator Strap-on Type

Safety Issues in Healthcare Programs / Healthcare Employment

Parts identification:

Chest Drains. All Covenant Health Intermediate Care Nursery staff. Needle Aspiration

Varithena Delivery System Instructions for Use

Photo: Jonas Wall ANTARES OVAL DRY GLOVE SYSTEM BY SI TECH.

2: How to Fill Veloci-T Cartridges

STANDARD OPERATING PROCEDURE ADVANCED INTRAVENOUS TRAINING ARM (S )

est rime Making products that make a difference at home Official Neotech Distributor All Products are Proudly Made in the USA Healthcare

Unblocking the MicroSprayer Aerosolizer Model IA-1B With the High Pressure Reverse Cleaning Adapter. Instructions for Use

SEI Certification Program Manual

RECONSTITUTION AND ADMINISTRATION INSTRUCTIONS FOR HEALTHCARE PROFESSIONALS

MAINTENANCE PROCEDURE FOR X 650

SPEMS SKILLS PROFICIENCY CRITERIA Paramedic

Veterinary Science Handling and Restraining Practicum. Restraint of the Cat for Cephalic IV Catheter Placement

the typical anatomy of the ear canal. The eartips should point in a forward direction as you insert them into your ear canals.

Stretching to serve the medical industry's needs. Flexibility at its best

RECONSTITUTION AND ADMINISTRATION INSTRUCTIONS FOR HEALTHCARE PROFESSIONALS. Hereditary Angioedema

Techniques To Treat Your Pain At Home (512)

Flat Fold Highchair INSTRUCTION MANUAL. Designed and manufactured to BS EN 14988: 2012 IMPORTANT:

First Aid Handbook. Contents

EMERGENCY CARE. Guidelines to Follow During Equine Emergencies

What is a wound? An injury to the skin and some times other deeper soft tissues. Types:

How to place the EQUIVET Ocular Lavage Kit

Blood Smear. Year Group: BVSc3 + Document number: CSL_L02

FIRST AID. Toolbox Talk

Hammar LifeJacket Inflator

VHC Vitamin-D Accurate Sample Preparation. VHC Vitamin-D Quantitative Vitamin D Test [REF] 1000J-10/-25/-50

3M Littmann Classic II S.E. Stethoscope

Wounds and Soft Tissue Injuries

Transcription:

22 2 3 4 5 Vitrex Steriheel Baby Sterile Cutting Safety lancet For high volume blood flow with minimum depth of penetration ACTIVATION BUTTON Secured by safety tab.. Release the trigger lock mechanism by pushing down the safety tab. 2. Reference position for infant heel blood sampling. 3. Raise the baby s foot to a suitable position, place the blade slot flush against the heel site and activate the lancet. 4. Collect the blood sample with a capillary tube. NO CHOCKING HAZARD Non detachable safety tab. 5. Dispose of the safety lancet in a suitable safety container. USER SAFETY Blade is fully shielded before and after use. EASIER HANDLING Anti-slip texture and one hand operation USER CONVENIENCE Pre-loaded, button activated design. PATIENT SAFETY Single-use only. Sterilised by gamma irridiation. WARNING: Do not use if safety tab has previously been activated or if the shield blister packing has been damaged. Specification Blister Packed 50 pcs 200 pcs 24000 pcs PATIENT COMFORT Ultra sharp blade with high speed cutting securing minimal trauma and fast healing. Green 0.65 mm /.40 mm Incision Length 33523 Micro-Preemie Orange 0.85 mm /.75 mm Incision Length 33423 Preemie NARROWED LANCING SLOT Easier positioning Yellow.00 mm / 2.50 mm Incision Length 33323 Newborn APPLICATION Primarily newborns and preemies. Can also be recommended for other applications where short penetration depth and/or minimal compression of tissue is important. Pink.4 mm / 2.80 mm Incision Length 33223 Newborn Plus Blue 2.00 mm / 3.00 mm Incision Length 3323 Toddler Steriheel Baby Safety Lancet 23

24 2 3 Vitrex Sterilance Press II Health workers worldwide face accidental needle-stick injury while caring for patients, putting themselves at risk to bloodborne illnesses including the AIDS virus and Hepatitis. PRESSURE ACTIVATION ensures a good blood sample every time. PATIENT COMFORT high quality, ultra sharp tri-bevel needle or bi-bevel blade, high speed penetration.. Carefully twist off the protective cap. WARNING: Do not use if protective safety cap has previously been removed. 2. Select site and press the device firmly against the site to release the lancet. 3. Dispose of safety lancet in a suitable safety container. Green 8G blade.8 mm 39323 Special baby care and maternity units for heel puncture Turquoise 30G needle.8 mm 39923 Low blood flow, less pain Purple 28G needle.8 mm 39823 Low blood flow, less pain Yellow needle.8 mm 39423 Diabetes clinics/hospital wards for Blue 2G needle.8 mm 39723 As Yellow but for increased blood flow Orange 2G needle 2.2 mm 39523 Haemoglobin (blood banks), cholesterol, blood typing, coagulation, blood gas and other diagnostic tests Pink 2G needle 2.8 mm 39623 As Orange but for thicker adult skin EFFICACY variety of point configurations and penetration depths to suit most capillary blood requirements. APPLICATION blood glucose and other in vitro diagnostic tests. Packaging 00 pcs 000 pcs 98000 pcs Press II Safety Lancet 25

26 Vitrex Sterilance Lite III For your safety and patient comfort BUTTON ACTIVATION PATIENT COMFORT high quality, ultra sharp tri-bevel needle or bi-bevel blade, high speed penetration. EFFICACY variety of point configurations and penetration depths to suit most capillary blood requirements. APPLICATION blood glucose and other in vitro diagnostic tests.. Twist off the protective cap. 2. Select fingertip insertion site slightly off centre to minimise any discomfort and maximise blood flow. Hold the lancet firmly against site and press the release button to activate the device. Green 8G blade.8 mm 37323 Special baby care and maternity units for heel puncture Purple 28G needle.8 mm 37423 Diabetes clinics/hospital wards for Yellow needle.8 mm 37523 Diabetes clinics/hospital wards for Blue needle 2.4 mm 37623 As above but for thicker adult skin Orange 2G needle.8 mm 37723 Haemoglobin (blood banks), cholesterol, blood typing, coagulation, blood gas and other diagnostic tests. For paediatrics and most normal adult skin Pink 2G needle 2.4 mm 37823 As above but for thicker adult skin 3. Gently massage the finger in the direction of the puncture site to obtain the required volume of blood. 4. Dispose of safety lancet in a suitable safety container. WARNING: Do not use if protective cap has previously been removed. 00 pcs 000 pcs 96000 pcs Lite III Safety Lancet 27

28 Vitrex Sterilance Lite II For your safety and patient comfort BUTTON ACTIVATION PATIENT COMFORT high quality, ultra sharp tri-bevel needle or bi-bevel blade, high speed penetration. EFFICACY variety of point configurations and penetration depths to suit most capillary blood requirements. APPLICATION blood glucose and other in vitro diagnostic tests.. Twist off the protective cap. 2. Select fingertip insertion site slightly off centre to minimise any discomfort and maximise blood flow. Hold the lancet firmly against site and press the release button to activate the device. 3. Gently massage the finger in the direction of the puncture site WARNING: Do not use if protective cap has previously been removed. Green 8G blade.8 mm 3733 Special baby care and maternity units for heel puncture Purple 28G needle.8 mm 3743 Diabetes clinics/hospital wards for Yellow needle.8 mm 3753 Diabetes clinics/hospital wards for Blue needle 2.4 mm 3763 As above but for thicker adult skin Orange 2G needle.8 mm 3773 Haemoglobin (blood banks), cholesterol, blood typing, coagulation, blood gas and other diagnostic tests. For paediatrics and most normal adult skin Pink 2G needle 2.4 mm 3783 As above but for thicker adult skin to obtain the required volume of blood. 4. Dispose of safety lancet in a suitable safety container. 00 pcs 000 pcs 90000 pcs Lite II Safety Lancet 29

30 Vitrex Sterilance Flex PRESSURE ACTIVATION ensures a consistent blood flow with every use. USER CONVENIENCE adjustable design provides three different penetration depths from a single unit - easy to use pre-loaded and pressure activated device. USER SAFETY is assured because the needle is fully shielded before and after use.. Carefully twist and pull off the protective cap WARNING: Do not use if protective cap has previously been removed. Blue.2 mm.8 mm 2.4 mm 2. Adjust the (adjustable) tip to choose the suitable depth. 3. Push the adjustable safety lancet firmly onto the chosen site to fire. 39993 Versatile adjustable lancet for most common use 4. Dispose of the adjustable safety lancet in a suitable safety container. 00 pcs 000 pcs 84000 pcs COMFORT is provided by high quality tri-bevel needle with high-speed penetration. Red.2 mm.8 mm 2.4 mm 39983 Versatile adjustable lancet for most common use APPLICATION can be used for blood glucose and other diagnostic tests. Flex Sterile Safety Lancet 3