Masoneilan* Model 78-80S & 08-80S Transfer Valves

Similar documents
Masoneilan* Model 78-80H & 08-80H Transfer Valves

Masoneilan* 78 Model Air Filter Regulator

GE Oil & Gas Model. Masoneilan* Air Lock-up Valve Instruction Manual. GE Data Classification : Public

Becker* Model FD-1500 Filter/Dryer

Masoneilan* Series Self Operating Pressure Regulators

Masoneilan * DSH * Series Desuperheater

Mooney* Series 21 Regulator

173 Series Self-Operating Pressure Regulators

Mooney* Flowgrid* Slam Shut* 1 Valve

1566 & Models

CSA Sample Draw Aspirator Adapter Operator s Manual

No.IL02-OM00011-A PRODUCT NAME LOCK UP VALVE. MODEL/ Series IL201 IL211

1805 Series Relief Valves

Installation Instructions JATCO Environmental Protection Tank Model J-5000CX

Discontinued. Powers Controls. Technical Instructions Document No P25 RV Rev. 1, May, RV 201 Pressure Reducing Valves.

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly.

VBL Volume Booster. Features. D103393X012 January 2013

299H Series. Introduction. P.E.D. Categories. Specifications. Installation. Warning. Installation Guide English September 2012

RK-IR Sample Draw Aspirator Adapter Operator s Manual

CLEMENTS. ANA Oxygen Regulator with Yoke Connector. User Manual. Manual No. ANA Issue 1

Instruction Manual 742 5/1/2009. Eclipse Ratio Regulators ES Series Version 1

Operation Manual Air Saver Unit ASV5000 Series

Series IRV1000/2000/3000

Power Valve: Precision Regulator. High precision, large capacity relief regulator

CF-SERIES HIGH FLOW REGULATORS

RK LEL Sample Draw Aspirator Adapter Operator s Manual

Maximum 0.85 MPa pressure setting Long-life, high flow perfect for balancer applications

Installation Instructions JATCO Environmental Protection Tank Model J-7000

Installation, Operation, and Maintenance Manual

30T A/Manual Hydraulic Shop Press

LUBRICATOR ASSEMBLY AND OPERATING INSTRUCTIONS

New Product. Air Consumption 70% Down. Precision Regulator Air Saving Type. RPE Series PRECISION REGULATOR RPE SERIES CC-1072A

VOLUME BOOSTER RELAYS YT-300 / 305 SERIES

61 Series Pilots for Pilot-Operated Pressure Reducing Regulators

DS06D,G Dial Set Pressure Regulating Valve

U S E R M A N U A L CAUTION. SAVE THESE INSTRUCTIONS Federal (USA) law restricts this device to sale by or on the order of a physician.

64 Series Pressure Reducing Regulators

Type ACE97. Introduction. Installation. P.E.D. Categories. Specifications. Overpressure Protection. Installation Guide English May 2002

1805 Series Relief Valves

Putting You In Control. Model 4411 Electropneumatic Transducer. Instruction Manual ES /10

THE HF-300 SERIES. Operating and Service Manual. Series includes all variants of HF-300/301

Interface Devices, Inc. Hydraulic Mini Mule

1305 Series Pressure Reducing Regulators

Standard Specifications

Instruction Manual LIMITED 1 YEAR WARRANTY. Hydraulic Punch Driver Read this material before using this product.

Index Table. Model 794. Installation, Operating and Maintenance Instructions

accidents which arise due to non-observance of these instructions and the safety information herein. SPECIFICATIONS

VBL Volume Booster. Instruction Manual Part Number: D103317X012, Rev. 1 Release: August 2013

THE MF-400 SERIES. Operating and Service Manual. Series includes all variants of MF-400/401

APCO ASU-SCAV & ASU-CAV SINGLE BODY COMBINATION AIR VALVES

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

RB Series Regulating System

LRS(H)4 USER MANUAL. Read the complete manual before installing and using the regulator.

PCS 340 Core Saturator : 115 Volt : 230 Volt. Instruction Manual

INSTRUCTION MANUAL. CVS P37 LP Gas Reducing Regulator

Instruction Manual No. 742, 8/98

NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE

Types 1808 and 1808A Pilot-Operated Relief Valves or Backpressure Regulators

Vacuum Saving Valve Series ZP2V How to Order ZP2V A5 03 Connection thread symbol for the pad Male thread connection Symbol Thread Applicable fixed ori

TESCOM 50-4X Series Safety, Installation & Start-Up Procedures

accidents which arise due to non-observance of these instructions and the safety information herein. SPECIFICATIONS

PRS(TC)4,8 USER MANUAL. Read the complete manual before installing and using the regulator.

Fisher 2625 and 2625NS Volume Boosters

Direct Operated Precision Regulator Modular Style. Standard Specifications

D05T Compact Design Pressure Regulating Valves

Techcon Systems TS1254 Pressure Pot

Model: 720-UL INSTALLATION OPERATION MAINTENANCE. Bermad Pressure Reducing Valve IOM. Model: FP -720-UL Sizes: 2"-12" BERMAD. Application Engineering

Type 310A-32A Pressure Reducing Regulator and Type 310A-32A-32A Working Monitor Regulator

Model GP PRESSURE REDUCING VALVE Installation & Operation Manual

Product Manual. Description. Specifications. CVS Type 1301F and CVS Type 1301G Regulator. Introduction

WW-720. Pressure Reducing Control Valve

VACUUM REGULATORS CONTENTS

Pressure Relief Valve Instruction Manual

Pressure-limiting valve and pre-load valve type MVG, MVE and MVP

SIX R (P ) AND SEVEN R (P ) POSITION CYLINDERS Service Information

Form No. P Meter, PD Series H8-S3 Flat Plate Cover Parts List

Operation & Maintenance Manual Place this manual with valve or person responsible for maintenance of the valve

Assembly-, installation- and maintenance instruction manual for bladder accumulators IBV / EBV , top reparable

Mounting and Operating Instructions EB EN. Type Supply Pressure Regulator. with increased air capacity

1301 Series High-Pressure Regulators

Installation Instructions

BACK PRESSURE VALVE. Instructions Parts List J

Fisher Lever Lock Handlever Actuators for POSI SEAL A81 Rotary Valves

AWG Fittings LLC. Pressure Relief Valve Up to 250 PSI. Product Number Read this instruction manual before use.

AIR DISTRIBUTOR. PART NUMBER (Including, but not inclusive) AD28483-_ALB, AD28563-_ALB, AD36097-_ALB, AD36098-_ALB, AD28485-_ALB

V DFX Series. Direct-Operated Tank Blanketing Regulator Manual D103808X012

DEEPSEA. Power & Light. Micro SeaLaser. Operator s Manual Ruffin Road San Diego, CA USA T: (858) F: (858)

Yoke Block Instruction Manual

P5523. Users Manual. Liquid to Gas Separator. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.

Compact Regulator. ARX20 Series. 2.0 MPa compatible, piston type compact regulator ARJ

LOCK UP VALVES YT-400/405/430/435 SERIES

Regulator for 2 MPa ARX 20. How to Order. Bracket. Pressure gauge. Port size 1/8 1/4. Panel nut

Type FEQ Slam-Shut Valve

INSTRUCTIONS PARTS LIST

I T T Pressure Reducing Valve WARNING INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

Type 3709 Pneumatic Lock-up Valve. Translation of original instructions. Mounting and Operating Instructions EB 8391 EN

OPERATING INSTRUCTIONS

DS05C,D,G Dial Set Pressure Regulating Valves

INSTRUCTIONS PARTS LIST U.S. PAT: 6,874,404; 6,516,707; 6,223,645

INSTALLATION INSTRUCTIONS. CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION

Transcription:

GE Oil & Gas Masoneilan* Model 78-80S & 08-80S Transfer Valves Instruction Manual GE Data Classification: Public

THESE INSTRUCTIONS PROVIDE THE CUSTOMER/OPERATOR WITH IMPORTANT PROJECT-SPECIFIC REFERENCE INFORMATION IN ADDITION TO THE CUSTOMER/OPERATOR S NORMAL OPERATION AND MAINTENANCE PROCEDURES. SINCE OPERATION AND MAINTENANCE PHILOSOPHIES VARY, GE (GENERAL ELECTRIC COMPANY AND ITS SUBSIDIARIES AND AFFILIATES) DOES NOT ATTEMPT TO DICTATE SPECIFIC PROCEDURES, BUT TO PROVIDE BASIC LIMITATIONS AND REQUIREMENTS CREATED BY THE TYPE OF EQUIPMENT PROVIDED. THESE INSTRUCTIONS ASSUME THAT OPERATORS ALREADY HAVE A GENERAL UNDERSTANDING OF THE REQUIREMENTS FOR SAFE OPERATION OF MECHANICAL AND ELECTRICAL EQUIPMENT IN POTENTIALLY HAZARDOUS ENVIRONMENTS. THEREFORE, THESE INSTRUCTIONS SHOULD BE INTERPRETED AND APPLIED IN CONJUNCTION WITH THE SAFETY RULES AND REGULATIONS APPLICABLE AT THE SITE AND THE PARTICULAR REQUIREMENTS FOR OPERATION OF OTHER EQUIPMENT AT THE SITE. THESE INSTRUCTIONS DO NOT PURPORT TO COVER ALL DETAILS OR VARIATIONS IN EQUIPMENT NOR TO PROVIDE FOR EVERY POSSIBLE CONTINGENCY TO BE MET IN CONNECTION WITH INSTALLATION, OPERATION OR MAINTENANCE. SHOULD FURTHER INFORMATION BE DESIRED OR SHOULD PARTICULAR PROBLEMS ARISE WHICH ARE NOT COVERED SUFFICIENTLY FOR THE CUSTOMER/OPERATOR'S PURPOSES THE MATTER SHOULD BE REFERRED TO GE. THE RIGHTS, OBLIGATIONS AND LIABILITIES OF GE AND THE CUSTOMER/OPERATOR ARE STRICTLY LIMITED TO THOSE EXPRESSLY PROVIDED IN THE CONTRACT RELATING TO THE SUPPLY OF THE EQUIPMENT. NO ADDITIONAL REPRESENTATIONS OR WARRANTIES BY GE REGARDING THE EQUIPMENT OR ITS USE ARE GIVEN OR IMPLIED BY THE ISSUE OF THESE INSTRUCTIONS. THESE INSTRUCTIONS ARE FURNISHED TO THE CUSTOMER/OPERATOR SOLELY TO ASSIST IN THE INSTALLATION, TESTING, OPERATION, AND/OR MAINTENANCE OF THE EQUIPMENT DESCRIBED. THIS DOCUMENT SHALL NOT BE REPRODUCED IN WHOLE OR IN PART WITHOUT THE WRITTEN APPROVAL OF GE. 2 GE Oil & Gas 2017 General Electric Company. All rights reserved.

Table of Contents 1. Overview 5 2. Specifications 5 3. Mounting 5 4. Adjustment 6 5. Maintenance 6 2017 General Electric Company. All rights reserved. Masoneilan Model 78-80S & 08-80S Transfer Valves Instruction Manual 3

Safety Information Important - Please read before installation These instructions dealing with M a s o n e i l a n Model 78-80S and Model 08-80S transfer valve contain DANGER, WARNING, and CAUTION labels, where necessary, to alert you to safety related or other important information. Read the instructions carefully before installing and maintaining your control valve. DANGER and WARNING hazards are related to personal injury. CAUTION hazards involve equipment or property damage. Operation of damaged equipment can, under certain operational conditions, result in degraded process system performance that can lead to injury or death. Total compliance with all DANGER, WARNING, and CAUTION notices is required for safe operation. This is the safety alert symbol. It alerts you to potential personal injury hazards. Obey all safety messages that follow this symbol to avoid possible injury or death. Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. Indicates a potentially hazardous situation which, if not avoided, could result in serious injury. Indicates a potentially hazardous situation which, if not avoided, could result in minor or moderate injury. About this Manual The information in this manual is subject to change without prior notice. The information contained in this manual, in whole or part, shall not be transcribed or copied without GE s written permission. Please report any errors or questions about the information in this manual to your local supplier. These instructions are written specifically for the Model 78-80S and Model 08-80S transfer valve, and do not apply for other valves outside of this product line. Warranty Items sold by General Electric are warranted to be free from defects in materials and workmanship for a period of one year from the date of shipment provided said items are used according to GE recommended usages. GE reserves the right to discontinue manufacture of any product or change product materials, design or specifications without notice. Note: Prior to installation The valve must be installed, put into service and maintained by qualified and competent professionals who have undergone suitable training. All surrounding pipe lines must be thoroughly flushed to ensure all entrained debris has been removed from the system. Under certain operating conditions, the use of damaged equipment could cause a degradation of the performance of the system which may lead to personal injury or death. Changes to specifications, structure, and components used may not lead to the revision of this manual unless such changes affect the function and performance of the product. When used without the safety alert symbol, indicates a potentially hazardous situation which, if not avoided, could result in property damage. Note: Indicates important facts and conditions. 4 GE Oil & Gas 2017 General Electric Company. All rights reserved.

1. Overview The Model 78-80S is a transfer valve combining a pilot valve of the floating ball type and three-port valve into one unit and is a standard-capacity three-way transfer valve of a set pressure regulating type. The other model 08-80S, is the same as the 78-80S except that a pilot valve is not combined and is the so-called three-way transfer valve. If several 78-80S are needed, one 78-80S can be installed, connecting 08-80Ss to it by mating the pilot outlet pressure ( SIG.OUT ) on the 78-80S to SIG on the 08-80S to simplify piping and achieve transfer. The structures of these models are shown on pages 8 and 9. 2. Specifications Maximum operating pressure Body 1.72Mpa Signal part 1.03Mpa Set pressure range : 100kPa to 700kPa Hysteresis : 34kPa or less CV value IN OUT 0.8 OUT EXH 1.3 Connection IN,OUT,EXH and SIGNAL connection ports Rc 1/4 (Option NPT 1/4) Operating temperature range : -30 to + 83 C (option: 0 to + 100 C) 3. Mounting Clean all the pipes before mounting the valve and completely remove dust, scale and other foreign matter. Mount the transfer valve as close to the actuator as possible and let air flow toward the IN and OUT marks located on the lower side of the body. When using the valve as a lock-up valve, put a blind plug in the EXH port. Two air connection ports to the pilot part are provided on the 78-80S, one being marked SIG and the other, SIG OUT. Connect the signal pressure to the port marked SIG. Use SIG.OUT for sending signal to the 08-80S when it is also mounted. The transfer valve functions to cut off IN and to connect OUT to EXH when the signal pressure lowers below the set pressure or is reduced to zero. Do not use signal pressure at air pressure exceeding 1.03Mpa (10.5kgf/cm2). Feeding signal pressure from near the IN side of the body will cause fluctuations in signal and air pressures. This may cause hunting. 2017 General Electric Company. All rights reserved. Masoneilan Model 78-80S & 08-80S Transfer Valves Instruction Manual 5

4. Adjustment The necessary settings of the transfer valve are generally performed at the factory and adjustment of it is not required. If, however, the setting pressure needs to be adjusted, make adjustment as follows: a) Loosen the lock screw (23) and turn the adjust knob (14) counterclockwise to release the compression of the spring (22). b) Turn the adjust knob (14) one or two turns clockwise to tighten it and to slightly compress the spring (22). c) Connect air pressure to IN marked on the body to check whether the body is open or closed. Then connect the pressure gauge and pressure reducing valve to the signal pressure connection port SIG. d) Apply supply air pressure and set the air pressure to SIG at specified pressure by operating the pressure reducing valve while watching air pressure to SIG on the pressure gauge. e) Turn the adjust knob (14) clockwise until air pressure no longer leaks through OUT marked on the body. f) This will cut off IN, and OUT and EXH will open in the transfer valve. g) Lastly, fasten the lock screw (23) and fix it. The ball (18) temporarily floats to transfer the pilot part and the valve emits a light beat tone when the set and signal pressures become the same. This is not an anomaly. The beating sound will stop when the transfer ends. 5. Maintenance Rubber is used in various parts of the transfer valve. Periodical exchange of this rubber every five years is recommended. Your valve will be checked and repaired at our factory if a check or a repair becomes necessary. Contact our agent or sales office for a check or a repair. 6 GE Oil & Gas 2017 General Electric Company. All rights reserved.

Transfer Valve Model 78-80S Sectional Drawing 2017 General Electric Company. All rights reserved. Masoneilan Model 78-80S & 08-80S Transfer Valves Instruction Manual 7

Part N Part Name Material Qty 1 Body ADC 12/ANODIZE 1 2 Housing ADC 12/CHROMATE 1 3 Plug SUS303/NBR 1 4 Piston ADC12/CHROMATE 1 5 Spring SUS304-WPB 1 6 O-Ring NBR 1 7 O-Ring NBR 1 8 O-Ring NBR 1 9 O-Ring NBR 1 11 Bottom Cap ADC12/CROMATE 1 12 Filter SUS304 2 13 Spring Case ADC12/CHROMATE 1 14 Adjust Knob VALOX420 1 15 Diaphragm Plate SUS303 1 16 Exhaust Orifice SUS303 1 17 Diaphragm NBR/POLYESTER 1 18 Ball SUS440C 1 19 Adjust Screw SUS303 1 20 Spring Button SPCC-SD 1 21 Spacer VALOX420 1 22 Spring SWP B 1 23 Lock Screw SUS304 1 24 Screw SUS304 4 25 Screw SUS304 8 8 GE Oil & Gas 2017 General Electric Company. All rights reserved.

New Transfer Valve Model 08-80S Sectional Drawing Part N Part Name Material Qty 1 Body ADC 12/ANODIZE 1 2 Head Cap ADC 12/CHROMATE 1 3 Plug SUS303/NBR 1 4 Piston ADC12/CHROMATE 1 5 Spring SUS304-WPB 1 6 O-Ring NBR 1 7 O-Ring NBR 1 8 O-Ring NBR 1 9 O-Ring NBR 1 11 Bottom Cap ADC12/CROMATE 1 24 Screw SUS304 4 25 Screw SUS304 4 26 Nut SUS304 4 2017 General Electric Company. All rights reserved. Masoneilan Model 78-80S & 08-80S Transfer Valves Instruction Manual 9

DIRECT SALES OFFICE LOCATIONS AUSTRALIA Brisbane Phone: +61-7-3001-4319 Fax: +61-7-3001-4399 Perth Phone: +61-8-6595-7018 Fax: +61-8-6595-7299 Melbourne Phone: +61-3-8807-6002 Fax: +61-3-8807-6577 BELGIUM Phone: +32-2-344-0970 Fax: +32-2-344-1123 BRAZIL Phone: +55-19-2104-6900 CHINA Phone: +86-10-5689-3600 Fax: +86-10-5689-3800 FRANCE Courbevoie Phone: +33-1-4904-9000 Fax: +33-1-4904-9010 GERMANY Ratingen Phone: +49-2102-108-0 Fax: +49-2102-108-111 INDIA Mumbai Phone: +91-22-8354790 Fax: +91-22-8354791 New Delhi Phone: +91-11-2-6164175 Fax: +91-11-5-1659635 ITALY Phone: +39-081-7892-111 Fax: +39-081-7892-208 JAPAN Tokyo Phone: +81-03-6871-9008 Fax: +81-03-6890-4620 KOREA Phone: +82-2-2274-0748 Fax: +82-2-2274-0794 MALAYSIA Phone: +60-3-2161-03228 Fax: +60-3-2163-6312 MEXICO Phone: +52-55-3640-5060 THE NETHERLANDS Phone: +31-15-3808666 Fax: +31-18-1641438 RUSSIA Veliky Novgorod Phone: +7-8162-55-7898 Fax: +7-8162-55-7921 Moscow Phone: +7 495-585-1276 Fax: +7 495-585-1279 SAUDI ARABIA Phone: +966-3-341-0278 Fax: +966-3-341-7624 SINGAPORE Phone: +65-6861-6100 Fax: +65-6861-7172 SOUTH AFRICA Phone: +27-11-452-1550 Fax: +27-11-452-6542 SOUTH & CENTRAL AMERICA AND THE CARIBBEAN Phone: +55-12-2134-1201 Fax: +55-12-2134-1238 SPAIN Phone: +34-93-652-6430 Fax: +34-93-652-6444 UNITED ARAB EMIRATES Phone: +971-4-8991-777 Fax: +971-4-8991-778 UNITED KINGDOM Bracknell Phone: +44-1344-460-500 Fax: +44-1344-460-537 Skelmersdale Phone: +44-1695-526-00 Fax: +44-1695-526-01 UNITED STATES Jacksonville, Florida Phone: +1-904-570-3409 Corpus Christi, Texas Phone: +1-361-881-8182 Fax: +1-361-881-8246 Deer Park, Texas Phone: +1-281-884-1000 Fax: +1-281-884-1010 Houston, Texas Phone: +1-281-671-1640 Fax: +1-281-671-1735 www.geoilandgas.com/valves *Denotes a registered trademark of the General Electric Company. Other company names and product names used in this document are the registered trademarks or trademarks of their respective owners. 2017 General Electric Company. All rights reserved. GEA33103 04/2017 (former Instructions JES0912ED)