PULSAR 5000 SERIES OPERATING & INSTALLATION INSTRUCTIONS SERIES 5000 PLEASE READ CAREFULLY BEFORE INSTALLING

Similar documents
GEMS SENSORS & CONTROLS

GEMS SENSORS & CONTROLS

P499 Heavy Duty Pressure Transducer

DPC-30 DPC-100. Reference Manual

CP10 Sensor Installation and Maintenance Instructions

DeltaSpan Pressure Transmitters LD10 Series Owner s Manual

P900. P900, Datenblatt Seite 1 DESCRIPTION

INSTRUCTION MANUAL MP4AR Remote Convection Gauge Range: 1 x 10-3 Torr to 1 x 10+3 Torr

Magnetic level switch type MR783 Instruction Manual

Operating Instructions for Intrinsically Safe Pressure Transmitters Series DMG/******** for Hazardous Application in Coal Mining Industry

High-performance submersible pressure transmitter For level measurement Model LH-10

SDX Submersible Depth Transmitter User Manual

T EK-SUB 4800C 19 mm Submersible Level Transmitter

Instruction Manual Contact Pressure Vacuum Gauge

P9000 DESCRIPTION. For parts requiring RoHS compliance, please contact factory. P February /6

SDX Submersible Depth Transmitter User Manual

Instruction Manual Differential Pressure Transmitter

THE MF-400 SERIES. Operating and Service Manual. Series includes all variants of MF-400/401

Electro-Pneumatic Converter YT-940 SERIES

Pressure Measurement Single-range transmitters for general applications

Spiratec ST14, ST16 and ST17 Sensor Chambers and sensors

Dual Solenoid Gas Valve Installation

High-performance submersible pressure transmitter For level measurement Model LH-10

Installation and Operation Manual

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

! Warning, refer to accompanying documents.

PLAQUE MFM0680 UNDERWATER LIGHT. Operating Instructions

OPTIBAR P 1010 C Technical Datasheet

FTS SUBMERSIBLE PRESSURE TRANSMITTER USER S MANUAL

Instruction Manual Differential Pressure Transmitter

Instruction Manual AD 1000 / BA 1000 Absolute Pressure Sensor

THE BP-301 SERIES. Operating and Service Manual. Series includes all variants of BP-301 (LF 0.1Cv / MF 0.5Cv)

KTE6000 / KTU6000 Series OEM pressure transmitters for industrial media

PV4 and PV6 Piston Valves

ISQB1 INTRINSICALLY SAFE ELECTRO-PNEUMATIC CONTROL VALVE INSTALLATION & MAINTENANCE INSTRUCTIONS HAZARDOUS AREA CLASSIFICATION

THE HF-300 SERIES. Operating and Service Manual. Series includes all variants of HF-300/301

Deep Submersible Level Transducer Series 300DS

MST21 Stainless Steel Balanced Pressure Thermostatic Steam Trap

METEOR LSR36500 LIGHTING UNDERWATER POOL LIGHT. Operating Instructions

200A Series ELECTRONIC LEVEL TRANSMITTER

GETZ EQUIPMENT INNOVATORS PART NO.: 9G59554 MODEL: MS 36 SC-R HYDROSTATIC TEST PUMP

SITRANS P measuring instruments for pressure

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

Instructions for Installation, Use and Maintenance FSI Safety Tank Shower Systems

RAM 4021 Operation Manual

INSTALLATION & MAINTENANCE INSTRUCTIONS

MODELS (2 foot Version) (4 foot Version)

9700 Transmitter Submersible hydrostatic level transmitter

RAM 4021-PR. Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

Dri-Line Mk2 Spirax-Monnier Compressed Air Drain Trap

Norrsken Family Booklet

D10S/D20S Wall/Post Mount Inflator Quick Start Manual

Instruction Manual BA90 Precision Barometer

Proportional Pressure-Relief Cartridge Valve, Size 2...4

2 Overview. SITRANS P measuring instruments for pressure. Transmitters for gage and absolute pressure. Z series for gage pressure

L 100. Bubble-Tube Level System. Installation, Operation and Maintenance Instructions

Colima TOR Magnetic Level Switches

Gas density monitor With integrated transmitter Model GDM-100-TI

THE HF-210 SERIES. Operating and Service Manual. Series includes all variants of HF-210/211. Issue A October 2014 *Section 6.

How to specify a product. Process Sensors and Mechanical Instruments

Transmitter CS 21 Operation Manual

Instrument Operating Manual

Angled Sign Light with Shade

Installation, Operating and Maintenance Instructions. V914 Cast Iron Flanged Swing Check Valve V914

CSA Sample Draw Aspirator Adapter Operator s Manual

Installation, operating and maintenance Instructions for Seemag bypass level indicator

GM-7000 Series CE Approved Gas Control Valve

RAM Operation Manual

FLANGED TWO-PIECE BALL VALVES

* * Data Sheet and Operating Manual. Digital manometer ME01 ## # 87 # HL S#### Dust explosion protection Zone 22.

DeltaSpan General Purpose Water Small Bore or Wastewater Pressure Level Transmitter LD34 and LD35 Series Manual

Inverse Proportional Pressure-Relief Cart., Size 2 4

SIX R (P ) AND SEVEN R (P ) POSITION CYLINDERS Service Information

FLANGED TWO-PIECE BALL VALVES

EASIDEW TRANSMITTER with Current Source Output

RD(H)20/25 Pressure-Reducing Regulator User Manual

Differential Pressure Transmiter

Transmitter CS 21 Operation Manual

Inverse Prop. Pressure-Relief Cart., Size 2 4

Manual Actuated Boiler Blowdown Valves

Type 3709 Pneumatic Lock-up Valve. Translation of original instructions. Mounting and Operating Instructions EB 8391 EN

THE BP-690 SERIES. Operating and Service Manual. Series includes all variants of BP-LF/MF-690/691

DK46 - DK800 Supplementary instructions

Gas Pressure Probe. Information Sheet. Total Dissolved Gas

_ pressure transducers. User Manual

Arran LED Floodlight Luminaire

L3 Pressure and Level transmitter

BGA244 Binary Gas Analyzer

Proportional Pressure-Relief Cartridge Valve, Size 2...4

Pressure Transmitter P41

Target disk flowmeter Series DP. Instructions manual DP65 DP500. R-MI-DP Rev.: 4 English version

PLAQUE MFM18240 UNDERWATER LIGHT. Operating Instructions

x act i Precision Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to IEC 60770: 0.

Mounting instructions. Strain transducer SLB-700A. B 26.SLB700A.10 e

Operating Manual VSA100A. tina29e1 ( )

Precision pressure sensor Basic version Model CPT6020

Instruction Manual EMA 84 Digital Pressure Gauge

SA121, SA122, SA123, SA128 and SA1219 Self-acting Temperature Control Systems (Dial Adjustment)

UNIK 5600/5700 Marine Certified Pressure Sensing Platform

Transcription:

PULSAR 5000 SERIES OPERATING & INSTALLATION INSTRUCTIONS SERIES 5000 PLEASE READ CAREFULLY BEFORE INSTALLING Please Note: Ranges above 500mbar are designed and manufactured in accordance with sound engineering practice as defined by the Pressure Equipment Directive 97/23/EC and must not be used as a safety accessory as defined by the Pressure Equipment Directive, Article 1, Paragraph 2.1.3. Ranges below 500mbar are exempt from the Pressure Equipment Directive. The CE Mark on the unit does not relate to the Pressure Equipment Directive. INTRODUCTION Series 5000 are low range fluid pressure measuring transducers and transmitters in which a ceramic capacitive sensor is used to convert fluid pressures into a proportional electrical signal. These instruments are suitable for long, continuous arduous service when operated within the published specifications. Series 5000 conform with the essential protection requirements of the EMC Directive 89/336/EEC amended by certified type testing to EN 50082-2 and EN 60081-1. Conformity with the requirements of the CE mark only applies when the installation conditions described in these instructions have been met. For units supplied without a cable assembly connection to the transducer must be accomplished using approved cable. see APPROVED CABLE section. All instruments conform to the appropriate specifications and/or drawings applicable and have been subjected to relevant strict quality control procedures. HAZARDOUS PRODUCTS The Consumer Protection Act of 1987, Section 6 of the Heath and Safety at Work Act 1974 and the Control of Substances Hazardous to Health Regulations 1988 require that we advise recipients and users of our products of any potential hazards associated with their storage. Handling or use. The products which our Company supplies may be classified as Electrical, Electro-Mechanical and Electronic equipment. These products are tested and supplied in accordance with our published specifications or individual special requirements that are agreed in writing at time of order. They are constructed so as not to affect adversely the safety of persons and property when properly installed, maintained and used by qualified personnel, in the applications for which they were designed and manufactured GENERAL

* Transducer should not be subjected to greater than the maximum allowable pressure or temperature as defined in the transducer specification. * Transducer should not be subjected to mechanical impact. * In the event of fire the end user must ensure that the system pressure is vented to a safe area. * The effects of decomposition of unstable fluids should be considered by the user when placing this device in service. * The pressure transducer has no means of draining or venting, this must be performed by another component in the end users system. * Pressure range must be compatible with the maximum pressure being measured. * Pressure media must be compatible with the transducer wetted parts which are stainless steel to UNS 31803, Ceramic and Nitrile * Exposed end of cable must be kept free from moisture. * Liquid must not be allowed to freeze in the pressure port. Full specifications for all products available on request from our Service Department. MECHANICAL INSTALLATION Pressure Connections: 1) G¼ internal pressure connection to BS2779. Alternative fitted as specified at time of order. 2) KF25 Flange Pressure couplings screwed into G¼ pressure ports should have a maximum thread engagement of 13 mm and UNDER NO CIRCUMSTANCES be allowed to touch the pressure sensitive diaphragm. Pressure couplings should be sealed against the outer face at the pressure port entry using bonded seal washer such as:- Part Number Description 234646-0002 G¼ bonded seal up to +100 C operation. Dowty Ref: 400-021-4490-02 499207-0002 G¼ bonded seal up to +200 C operation. Dowty Ref: 300-021-0967-02 499207-0006 G1/8 bonded seal up to +200 C operation. Dowty Ref: 300-020-0967-02 Refer to Dowty for external pressure ratings. Mounting: Pressure Transducer is designed to be attached by the coupling thread. Alternatively units fitted with an immersible cable can be suspended via the cable or flange. Omni-directional. To fit, use a M16 (5/8 UNF) AF spanner on the hexagon provided and apply maximum torque of 27 Nm (20 lbf-ft). The Customer must ensure that the pressure seal is suitable for the application.

Effects of Heat: Avoid mounting the transducer near a source of heat which is liable to create a temperature gradient across the instrument. If this is unavoidable, use a heat shield to deflect uneven radiated heat or wrap the transducer in glass fibre insulation so that an even temperature is assumed throughout. ELECTRICAL INSTALLATION All types include suppression devices providing transient protection to EN 61000-4-2 and EN 61000-4-4. For all types conformity with the requirements of the CE mark only applies when connection is made with approved cable, See APPROVED CABLE section, and the screen of that cable is connected to a reliable earthing point at the instrumentation end. APPROVED CABLES Pulsar pressure sensors are supplied with cable comprising 7 colour-coded cores, with a central vent tube, enclosed by an aluminium/polyester screen where the screen is in intimate contact with a separate drain wire. The outer sheath material is Polyurethane (immersible, +50 C). Alternative outer sheath materials available on request for harsh environments. OPERATION Having installed the transducers as instructed they are ready for use. The transducer should not be removed whilst the system is at pressure. Before applying power, check that the correct polarity and excitation levels are being applied. See ELECTRICAL REQUIREMENTS. Cable Version: Connector Version: Process Media: -20 C to +50 C -25 C to +85 C -40 C to +100 C OPERATIONAL LIFE: Limited to 10 million full scale cycles. CALIBRATION Transducers are calibrated to the range requested at time of order. atmosphere via the electrical connection Gauge datum vented to ADJUSTMENT OF ZERO AND SPAN CONTROLS Switch and potentiometers provide continuous adjustment over the range 110% to 32% of nominal pressure range. (See Table below) Zero and span controls are precisely set during manufacture and should only read adjustment if there is a change in the required pressure measurement. Access to these controls is provided by means of a removable end plate. Remove the 3 retaining screws using 2.5m A/F hex wrench and withdraw end plate. Caution: Care should be taken in withdrawing end plate so as not to disconnect internal plug.

To maintain sealing integrity ensure end cap O ring is correctly seated, and clean prior to refitting. RANGE SWITCH DETAILS Switch Position Switch Position Range (Current Mode) (Voltage Mode) Range 0 Not Used 8 W 1 Not Used 9 X 2 Not Used A Y 3 Not Used B Z 4 W C Not Used 5 X D Not Used 6 Y E Not Used 7 Z F Not Used Range Downranging Scope (Nominal) W 110 to 74% X 78 to 52% Y 54 to 37% Z 47 to 32% LOAD RESISTANCE (4-20mA Transmitter) The total permissible resistive load in the loop (to include all the cable resistance) can be from 'zero to 50 x (supply volts -8.5) ohms'e.g. with a 12V d.c. supply the permissible load is from zero up to 175 ohms (Figure 1). Figure 1

MAINTENANCE Routine Inspection: Not required except for periodic inspection of the cable and moulding to ensure that these are neither damaged nor softened by incompatible liquid. CAUTION CARE MUST BE TAKEN NOT TO TOUCH THE PRESSURE SENSITIVE DIAPHRAGM WHILST CLEANING THE PRESSURE PORT. FAILURE TO OBSERVE THIS PRECAUTION CAN CAUSE IRREPARABLE DAMAGE. WARRANTY The Company warrants its products to be free from defects in material and workmanship in normal use and service for a period of two years from date of shipment. The Company reserves the right and option to refund the purchase price in lieu of repair or replacement upon evaluation of the returned original part. Modification, misuse, attempted repair by others, improper installation or operation shall render this guarantee null and void. The Company makes no warranty of merchantability or fitness for a part or purpose. SERVICING The transducer cannot be repaired locally and if damaged should be returned to ourselves at the address shown below: Pulsar Process Measurement Limited Oak House Bromyard Road Worcester Worcestershire WR2 5HP RETURN TO FACTORY PLEASE NOTE: To comply with Health and Safety requirements, the instrument must be clean and safe to handle and accompanied by a formal statement to that effect duly signed by an authorised officer of the Company. W A R N I N G * IF INSTRUMENT IS SUBJECTED TO +400 C PLUS Some instruments use Viton sealant. Above +400 C this material decomposes producing (amongst others) Hydrofluoric Acid which is extremely corrosive

* DO NOT ALLOW CONTACT WITH SKIN If it is suspected that an instrument has been subjected to temperatures in excess of +400 C * CONTACT OUR SALES OR SERVICE DEPARTMENT TO ASCERTAIN IF THE INSTRUMENT CONTAINS VITON W A R N I N G ELECTRICAL CONNECTIONS 4-20MA VOLTAGE IN+ IN- EARTH IN+ COM OUT+ EARTH CABLE R BL DRAIN R W Y DRAIN CONNECTOR 1 2 E 1 2 3 E OUTPUT SUPPLY VOLTAGE 4-20mA 9-35V d.c. 0.5-5.5V d.c. 7.5-35V d.c. 1-6V d.c. 8-35V d.c. 0-5V d.c. 7.5-35V d.c. 0.1-5.1V d.c. 7.5-35V d.c. 1-5V d.c. 7.5-35V d.c.