Develop and sign off on risk assessment/work method statement for the task, considering task specifics elements that will affect the user s safety:

Similar documents
HEIGHT SAFETY. Elasticised shock absorbing Lanyard Twin tail lanyard allowing transfer to adjacent anchors

??????? is committed to providing a safe work environment for its employees and preventing occupational injuries due to falls.

To find an approved WAH training course and provider in your area, follow this link:

DREW UNIVERSITY FALL PROTECTION PROCEDURE (DRAFT 12/11)

Height Safety PPE & Rescue Equipment. Horizontal safety cable and rail inspection. Ladder safety cable and rail inspection.

FATAL AND SEVERE RISK PROGRAM

Anchor on the Go. Portable Roof Anchor for Metal Roofs. Part Number Patent Number Installation and Operating Instructions

GUIDE 2002 HEALTH AND SAFETY FOR ARTIFICIAL CLIMBING STRUCTURES AND OPERATIONS FOR DESIGNERS, MANUFACTURES, SUPPLIERS, OPERATORS AND USERS

Fall. protection. for the. real world. The Protecta Product Range

LADDERS FIXED AND PORTABLE

ROOF ANCHOR TO GO INSTALLATION & OPERATING INSTRUCTIONS. AZ-200 Portable Roof Anchor for Metal Roofs. zero4heightsafety.com

KG Training and Assessing. IMPORTANT! You must read this letter!

11.4 FALL-ARREST SYSTEM AND EQUIPMENT CHECKLIST (Must answer yes to all applicable questions)

Occupational Protective Equipment

Safe Work Method Statement

Technical Briefing Note

ARKANSAS TECH UNIVERSITY FACILITIES MANAGMENT HEALTH AND SAFETY MANUAL

FALL PROTECTION COMPARISON BETWEEN VARIOUS OSHA STANDARDS, NAVY and EM 385 (2008) REQUIREMENTS

Building 68 Roof Safety Assessment

Applying Construction Fall Protection Concepts to General Industry

Know Your ABCs FALL PROTECTION GUIDE

Section 16B. Fall Protection. Falls are the second leading cause of death in the workplace. Factors contributing to falling incidents:

Prevention of Falls and Working at Heights

Fall Protection and Elevated Work

New Mexico Institute of Mining & Technology. Fall Protection Program

"FALL PREVENTION IN THE WORKPLACE"

Rescue Ladder Model: CTB LDR-RSC 18ft (5.48m)

Department of Facilities Management. Occupational Health and Safety. Fall Protection Program

1.0 Scope and Application

Height Safety IWR LI FTING

A GUIDE TO BUYING FALL ARREST EQUIPMENT. uk.rs-online.com (UK customers) (International customers)

RIGGERS SAFETY SAFETY IS IN THE DETAILS FULL LINE CATALOG

Operation and Instructional Techniques Manual

Thanks To Our Sponsors Platinum Sponsor NS Department of Labour and Workforce Development

Progressive Safety Services LLC

Height Safety Lifting Load Control

FALL PROTECTION. Leader s Guide. Marcom Group Ltd.

What is fall protection?

FALL PROTECTION GUIDELINE

8. Fall Protection Procedures WAC

You may order this publication from WCB Publications and Videos, Please quote ordering number BK60.

RIGGERS SAFETY SAFETY IS IN THE DETAILS FULL LINE CATALOG

FALL RANGE PROTECTION

Building 43 Roof Safety Assessment

Building 32A Roof Safety Assessment

Kratos Safety FA FA FA FA POINT LUXURY FULL BODY HARNESS

FALL PROTECTION SAFETY PROGRAM

Instructions for Y Style Full Body Harness Model YH130

Fall Protection Equipment

"FALL PROTECTION IN CONSTRUCTION ENVIRONMENTS"

Instructions for The Rose Crossover Style Full Body Harness For Women

WARNING! DO NOT THROW AWAY THESE INSTRUCTIONS! READ AND UNDERSTAND BEFORE USING EQUIPMENT!

Compliance Is the First Step on the Safety Ladder Understanding the final walking-working surface rule from OSHA and how Honeywell ladder solutions

The purpose of this training is to give field technicians awareness training and guidelines on potential hazards they may encounter in the field.

Building 21 Roof Safety Assessment. Multi Story Building with large metal roof areas Exteral access required for window cleaning UOW01613

Risk Control at United Fire Group

FALL PROTECTION PLAN INSTRUCTIONS

MSA Fall Protection Kits

Fall Protection Plan. Chinook Drilling 8/10/2012

2018 INSPECTION REPORT

FALL PROTECTION CODE OF PRACTICE

SYSTEM OPERATION PROPRIETARY ROPE ACCESS ANCHOR POINT SYSTEMS FOR FACADE & WINDOW ACCESS MANUAL SYSTEM CONTENTS

Region: USA Language: EN Number : TB0031 Revision : B. Total Page: 3 Page n : 1 First Issue: 10/2014 Rev. Date: 10/08/2014

Rescue Ladder Model: KT ft (5.48m)

Rescue Ladder Basic Kit Model: FS-EX243 18ft (5.48m)

OPE Training Seminar Agenda

Product Name: Hold Me Rope Anchor

Rope Grab Operation & Maintenance Manual

Rescue Ladder Basic Kit Model: LDR-BAS-CTS 18ft (5.48m)

Tower Climber Orientation.

Fall Protection Checklist. Guardrail System

A variety of other devices can be used with the front dee ring, but please check for suitability.

Fall Protection. Fall Speed vs. Reaction Time. Good body reaction time = 0.5 seconds Travel distance in 0.5 seconds = 4 feet (1.21mts.

Fall Speed vs. Reaction Time

FALL PROTECTION PLAN FALL PROTECTION PROGRAM

Fall Protection / Open Holes & Guardrail

Building 30 Roof Risk Assessment

Operating instructions. Bolt-on Bar Joist Anchorage

Fall Protection 4/7/16

Safety Manual Page 1 of 15

INSTALLATION AND USAGE HANDBOOK

FALL PROTECTION PLAN July 2012

Work At Heights Toolkit. for Supervisors

Fall Protection STANDARD PROCEDURE INSTRUCTION. Fall Protection. Title SPI. Department. Supersedes SPI Dated. Jan 19, 2016.

HotWorks Harness Range User Weight Limits (*kg) - Harness to Lanyard - 160kg Attachment Hardware VVVV Rear D Alloy hardened steel for increased tensil

Reliance Industries, LLC Operating instructions for the / Bolt-on D-Ring Anchorage. Model # 3071

FALL PROTECTION / ELEVATED WORK

Fall Protection. ANSI-What is it, Why is it important? Craig Firl. March 5 th, Company Private

Working at Heights Training Checklist (Ontario Version)

workplace fatalities involving falls to a lower level. Fall related fatalities make up 16% of workplace fatalities

Fall Protection ABC s

Fall Protection Introduction

Doc No: FPP CARDINAL SURVEYS COMPANY. Safety Management System. Initial Revision Date: Version Revision No. 02 FALL PROTECTION

Building 9 Roof Safety Assessment

A PERMANENT SAFETY LINE FOR WORKING AT HEIGHT

Working at Height. A printed or saved copy is an UNCONTROLLED copy. Check that it is the latest available version before use.

CHAPTER 10 FALL PROTECTION

INDUSTRY CODE DRAFT PERMANENT ANCHORS, LIFELINE AND RAIL INSTALLATIONS FOR WORKING AT HEIGHT

FALL PROTECTION PROGRAM (OHS-0010)

American National Standards Institute, ANSI Z359 Fall Protection Code Update

Transcription:

Safe Use Step 1 Complete your site induction with the RIS Altitude system owner and confirm that the users can demonstrate competence in the activity of working at heights by provision of a nationally recognised certification or equivalent. Step 2 Develop and sign off on risk assessment/work method statement for the task, considering task specifics elements that will affect the user s safety: Type of work Length of time required to complete the work Surface conditions Materials to be used Ladder requirements Placement of the materials Additional hazards introduced by the task such as: o Working around plant and equipment o Working near energised electrical installations o Public safety and security o Dropped objects PPE, plant and equipment inspection pre-use (ladders, scaffold, scissor lifts etc) Rope length requirements for the work Anchor testing requirements Rescue requirement s for any activity where fall arrest techniques are to be used Safety Warning: RIS Altitude systems are designed to be used by competent trained persons only. The way all RIS Altitude systems are used will be relative to a range of variables not able to be captured in this operations manual. These user instructions are indicative only and may change depending on site conditions, types of work required to be completed and number of person involved in the task. Progressing to complete work without assessing and controlling the risk relative to the work and the use of the systems is in contravention of work health and safety regulations and highly dangerous and not recommended. The above list is not exhaustive. Should you require more information on task specific risk assessment, user training or work health and safety regulations relevant to your workplace, please contact your local RIS branch before progressing with the work

Safe Work Method Statement Roof Anchors Ensure that all people working on roof have been competently trained in Height Safety and possess a Height Safety ticket. Make sure you possess and wear the correct equipment. ACCESS TO ROOF AREA IS VIA: PERMANENT LADDER (ART & GYM & O BRIEN BUILDINGS) INFORM MANAGEMENT OR SECURITY THAT WORK IS BEING CONDUCTED ON THE ROOF AREA BEFORE COMMENCEMENT OF ANY WORKS ALWAYS WORK ON THE ROOF AREA WITH A SECOND PERSON. Connect the 1.5m Shock absorbing Lanyard to the rear D ring via the karabiner/snaphook. Connect the Personal Shock Absorber to the frontal D ring of the harness via the karabiner. Fit harness as per fitting instructions. Connect the Rope Grab Fall Arrestor to the Rope. Connect the Rope Grab Fall Arrestor & Rope to the free end of the 1.5m Shock Absorbing Lanyard via the Karabiner. Make sure harness is fitted correctly. Make sure all attachments are fitted securely and correctly. Carry 15m rope with rope grab either by securing over shoulder or in a backpack. Locate the ladder bracket for securing permanent ladder. Position the permanent ladder securely between the bracket. NOTE Position the ladder at a maximum ratio of one out to four up. Obtain access to the roof by climbing the permanent ladder 1. Climb the permanent ladder 2. Always ensure that you have three points of contact on the ladder and stop in a position where you can reach the strop safely. Connect the free end of the Personal Shock Absorber to the anchor strop via the karabiner ensuring it has been passed over the ladder extension. Climb onto the roof Walk to the anchor point you wish to connect to. Connect the free end of rope to the anchor point via the karabiner. Make sure the Adjustable Rope Grab & Rope is securely attached to the anchor point. 1 Use Ladder in accordance with the safety guidelines set by WorkCover for portable ladders. 2 Use Ladder in accordance with the safety guidelines set by WorkCover for portable ladders.

Walk to the high side of the anchor point ensuring you are greater than 2 metres way from edge. Disconnect the Personal Shock Absorber from the Frontal D ring and place on roof ready for egress. NOTE: If the roof slope is greater than 15 degrees the user must remain connected to an anchorage point at all times. NOTE - When utilising the Adjustable Rope Grab & Rope system it is important that the user adjusts the lanyard length (i.e. make sure the Rope and Shock Absorber are taut to prevent any working slack. It is advisable to have NO working slack. Perform the work required using care. NOTE When accessing the corners of the building connect the Karabiner to the Adjustable Rope and then connect the Karabiner to the Diversion Anchor to prevent a pendulum effect. Detach yourself from the anchor point only when you are in a position (i.e. greater than 2 metres from the edge) To attach to the other anchor points, ensure that you repeat the above steps Note: if the roof is unsafe or to steep to transfer safely, a second Adjustable Rope Grab & Rope is required. Note: 1. Always attach to the anchor point that is directly behind you. 2. Do not pass another anchor without being attached to it. 3. Using an anchor that is not directly behind you will cause a pendulum effect. Once all work is complete, return to the access anchor & Strop. Connect the Personal Shock Absorber to your front D ring on the Karabiner. Secure rope over shoulder or in a back pack Climb back onto the ladder. Take a few steps down. Disconnect the Personal Shock Absorber from the anchor strop via the karabiner. Descend the ladder ensuring three points of contact at all times. Return all equipment used to the appropriate Storage Area or to the Building Maintenance Manager.

Recommended Personal Fall Protection Equipment per user: 1 x TRR01 Riggers Fall Arrest Harness 6 x L024T Karabiners Twistlock 24mm opening 2 x ROPEK15M 15m Kernmantle Rope with Rope Grab 1 x WL01-T 1.5m Webbing Lanyard with shock absorber 1 x WLSA01-T 300mm shock absorber 1 x AK040 Backpack kit Bag 50m capacity

GENERAL CONFIGURATION OF SAFETY SYSTEM LADDER The Aluminium Fixed access ladder installed at the Christian Brothers College site has been manufactured with the highest level of safety in mind and to ensure compliance with Australian and International Standards. The extra strong frame ensures a very stable and rigid ladder even at considerable heights. The Ladder Rungs have been specially designed to provide superior grip and support, ensuring a higher level of safety while climbing the ladder. WALKWAY The RIS Walkway System system provides safe access to roof top Mechanical Plant. RIS Walkway is lightweight yet incredibly strong and virtually maintenance free, which provides a simple solution to safety in the workplace. The system is compatible with the vast majority of roof profiles available. All walkways/platforms and handrails are designed to meet the relevant requirements of AS/1657-2013. Roofsafe only manufacture, distribute and promote products that meet or exceed the relevant standard AS/NZS 1891.4, AS5532, AS4488 & AS1657-2013 and comply with the Code of Practice Safe Work on Roofs and Occupational Health and Safety Regulations 2001. Roofsafe products have been independently tested by Testsafe Australia assured by their ISO 9001 quality management systems and accredited by NATA testing laboratories.

User Competence and Risk Assessment People that work at heights are exposed to the risk of falling. Falling from heights at work is one of the most common causes of serious injury and death in the Australian workplace. Installing safety systems is one element of managing these risks. In order to meet the full requirements of all State, Territory and Commonwealth Work Health and Safety Laws and Regulations, fall prevention system users must be competent in the use of the systems, and a risk assessment must be undertaken prior to use. Every system will have subtle differences that may impact the way a user can operate the system effectively. Issues such as the work environment, type of work, access and other activities in close proximity to the work must be considered before beginning work, and must be part of a documented pre-start risk assessment. Work Health and Safety Regulations require that the person commissioning the work ensures that those completing the work (be they an employee, contractor or volunteer) have a thorough understanding of the risks involved with the work and can demonstrate competence in completing the task, including being prepared to react to a rescue scenario where fall arrest systems are utilised in a workplace. For further information or help on local requirements, instruction in risk assessment, and development and training in the use of RIS Altitude systems for your workers (employees, contractors or volunteers), get in touch with your local branch today.

Periodic Inspections Testing & Certification The RIS Altitude products that form the system are tested and certified to the following Australian standards: AS/NZS 1891.2 Industrial Fall Arrest Systems & Devices Part 2: Horizontal Lifeline and Rail Systems AS/NZS 1891.3 Industrial Fall Arrest Systems & Devices Part 3: Fall Arrest Devices AS/NZS 1891.4 Industrial Fall Arrest Systems & Devices Part 4: Selection, Use & Maintenance Your RIS system(s) requires regular inspections to ensure they remain fit for use. Every location will have differences, and the inspection time frames will be relative to possible deterioration caused by many factors including but not limited to age, weathering, site conditions and usage factors. Inspection time frames may differ based on a risk assessment and depending on the product type. As the manufacturer of the product, RIS recommends inspection time frames in alignment with Australian Standards recommendations of 12 months. RIS may recommend alternative inspection time frames in the following cases: 1. Frequently used systems a. Any RIS systems that is used more than 5 time in 1 week 2. Infrequently used systems a. Any RIS systems that is used less than 1 time in 12 months 3. Once off installation not to be used again Inspections should be carried out by a competent height safety inspector that can demonstrate a capacity to inspect the systems thoroughly against the installation and certification criteria set out below: Has been trained and certified by RIS to undertake inspections and certification activity for RIS products. Demonstrates relevant industry experience in the inspection and use of height safety equipment. Can develop and implement a risk management approach to the inspection of the systems in order to inspect and review suitability prior to connecting to the anchor. Can demonstrate capacity to update and advise the owner at the time of the inspection regarding any defects and warranty issues. Works within the guidelines of the professional indemnity insurance carried by RIS that protects the systems owner from liability for the activities relevant to certification and inspection of new and existing systems. Provides a signed work method statement prior to the inspection relevant to the inspection, including the RIS systems recertification inspection criteria.

Appendix HARNESS ATTACHMENT PROCEDURE NOTE: Ensure that you have removed all items from your pockets before donning your harness. Fitting Instructions for TRRW01 Roofworkers Fall Arrest Harness:

Find the top of the triangular delta at the back of the harness. Alternatively, identify the front and back of the harness. Identify a label sewn at the apex of the delta marked "ATTACHMENT POINT FOR FALL-ARREST". The triangular delta rests on your back with the attachment point "D" ring positioned on the outside between your shoulder blades. Identify the frontal ATTACHMENT POINT FOR FALL - ARREST Put your right arm between the triangular delta and the shoulder straps. Pass your head through the V in the shoulder straps. Make sure that the shoulder straps are not twisted. Locate the waist belt and connect to the waist buckle. The waist belt and waist buckle are the same colour. Make sure that webbing straps are not twisted. Identify the left cross over strap below the frontal attachment point. Connect to the left buckle of the strap with the buckle having the black patch. Identify right leg strap and connect to right buckle. Identify left leg strap and connect to left buckle. Adjustment Instructions for Full Body Harnesses: The harness should be comfortable without undue pressure on the shoulders, thighs or pelvis. A good guide is to use your open hand and clenched fist to determine if the adjustment is correct. You should be able to pass your open hand between all webbing straps and your body. You should not be able to pass your clenched fist between all webbing straps and your body. If you can, readjust all buckles. To ensure maximum safety and comfort, adjust your harness in the following sequence: Adjust the waist belt first.

Position the waist belt just on or just below the navel. Semi-squat and adjust both leg straps at the same time to the same length. Stand erect and adjust buckles on your shoulder straps. Adjust the frontal attachment so that it is positioned on the sternum in the center of your chest.