1. Study the performance of a binary distillation column operated in batch mode.

GCMSD-Headspace Analysis SOP

Quantitative Analysis of Hydrocarbons by Gas Chromatography

Standard Operating Procedure. Air Displacement Pipette Calibration

Liquid -Vapor. Contacting columns

CHM250 Calibration and Measurement Lab. Balance Calibration

11.1 Dumas Method - Pre-Lab Questions

The pipettes cover a volume range from 0.1µl to 10ml.

UNCC Biotechnology and Bioinformatics Camp. Dr. Jennifer Weller Summer 2010

TEMPERATURE S RELATIONSHIP TO GAS & VAPOR PRESSURE

Exploring the Properties of Gases

Lab Skills Practice: Pipetting Small Volumes. B3 Summer Science Camp at Olympic High School 2016

VOLUMETRIC TECHNIQUES

The Gas Laws: Boyle's Law and Charles Law

1. If grams of the vapor of a volatile liquid can fill a 498 ml flask at o C and 775 mm Hg, what is the molecular mass of the gas?

Hydrostatics Physics Lab XI

Operating Instructions

Laboratory #2 Pipetting Technique and Micropipette Calibration Skills=40 pts

Pipette apparatus. Meet the difference. Manual. T E I

Experiment #12. Gas Laws.

Inquiry Module 1: Checking the calibration of a micropipette

CHM111 Lab Gas Laws Grading Rubric

Pipetting Small Volumes

Exploring the Properties of Gases

R: The Ideal Gas Constant Pre-Lab Assignment

Exploring the Properties of Gases. Evaluation copy. 10 cm in diameter and 25 cm high)

CH2250: Techniques in Laboratory Chemistry. Outline Measuring Mass Measuring Volume Significant figures. Mass Measurement

Purpose. Introduction

LOW PRESSURE EFFUSION OF GASES revised by Igor Bolotin 03/05/12

Tips for Proper Pipette handling and Maintenance. D. Muruganand, Ph.D ILQA - Bangalore, Feb 2014

PURE SUBSTANCE. Nitrogen and gaseous air are pure substances.

Improve pipetting results in pharmaceutical formulation by using MICROMAN E

Cover Page for Lab Report Group Portion. Head Losses in Pipes

DSTWU A Shortcut Distillation Model in Aspen Plus V8.0

SOP: Buck Scientific BLC-20P HPLC Operation

Laboratory Activity Measurement and Density. Average deviation = Sum of absolute values of all deviations Number of trials

The Ideal Gas Constant

Additional Reading General, Organic and Biological Chemistry, by Timberlake, chapter 8.

LOW PRESSURE EFFUSION OF GASES adapted by Luke Hanley and Mike Trenary

The use of the analytical balance, and the buret.

EXPERIMENT XI. Careful!! Improper handling of the vacuum line may result in the release of SO 2 which is an irritating and suffocating gas.

2. Determine how the mass transfer rate is affected by gas flow rate and liquid flow rate.

Operating Instructions

Before you start sampling, be sure to read

Experiment 8 GAS LAWS

Name:. Correct Questions = Wrong Questions =.. Unattempt Questions = Marks =

Lab 1. Instrumentation Familiarity: Using Micropipetters and Serological Pipettes

Physics Experiment 17 Ideal Gas Law Qualitative Study

Eliminating Sources of Pipetting Error in the Forensic Laboratory David M. Epstein Director of Scientific Operations. Abstract.

5890II GC Standard Operating Procedure 9/2/2005

VWR UHP j :01 Page 1. ENGLISH 1 22 DEUTSCH FRANÇAIS ESPAπOL ITALIANO

Separation Columns (Distillation)

Part 1: Distillation and Analysis of an Unknown Alcohol Mixture

Objective To identify a pure liquid substance using the physical properties of solubility, density, and boiling point.

Gas Absorption Column CAG

Experiment 13: Make-Up Lab for 1408/1420

Vapor Pressure of Liquids

1. Determining Solution Concentration

MULTICHANNEL. Labnet International, Inc.

A Depletion Compensated Wet Bath Simulator For Calibrating Evidential Breath Alcohol Analyzers

Students measure the change in pressure by varying the volume of trapped air in a syringe while:

Technical Procedure for General Laboratory Equipment

Fun with Gas Laws. Prepared by Vance O. Kennedy and Ross S. Nord, Eastern Michigan University PURPOSE

Target Density Lab SCIENTIFIC. Density Inquiry Lab Activities. Introduction. Concepts. Materials. Safety Precautions. Preparation

Liquid Handling Systems

The Decomposition of Potassium Chlorate

SOLUBILITY OF A SOLID IN WATER

Any laboratory is equipped with specific tools, equipment,

Register your instrument! Eppendorf Xplorer / Eppendorf Xplorer plus. Adjustment

IN-PLACE DENSITY WAQTC FOP AASHTO T 209 (16)

Buoyancy and the Density of Liquids (approx. 2 h) (11/24/15)

End of Chapter Exercises

How to Measure R7.1. Reference. I. Linear dimensions

AP Lab 11.3 Archimedes Principle

Using a micropipette to transfer exact liquid measurements in scientific experiments By: Nicole Hume

Gas Laws: Boyle s and Amonton s Laws MCTC Chemistry v.9.17

Gas Laws. Figure 1: Experimental Set-up with Leveling Bulb. GCC CHM 151LL: Gas Laws GCC, 2019 page 1 of 8

Operating Instructions METTLER TOLEDO Pipette Check Application for AX and MX/UMX Balances Version 1.xx

BASIC LABORATORY TECHNIQUES (Revised )

Measuring Mass and Volume

Air Pycnometer. Operating Manual. Umwelt-Geräte-Technik GmbH

Experiment 13 Molar Mass of a Gas. Purpose. Background. PV = nrt

Dynamics and Control of Chemical Processes Solution to Lab #8 Shutdown of C4-C5 separation section

BASIC LABORATORY TECHNIQUES (Revised )

Gel Loading Practice MiniLab

Physics 1021 Experiment 4. Buoyancy

Hands-On Experiment Density and Measurement

Experiment 18 Properties of Gases

Boyle s Law: Pressure-Volume Relationship in Gases

Transcription:

Felles Lab: Distillation Columns Separation September, 2012

Contents 1. Objectives... 2 2. Required Knowledge/Support Literature... 3 3. Brief Theory... 5 3.1. Definitions... 5 4. Equipment... 7 5. Planning the Experiment... 9 5.1. Writing the Work Plan... 9 6. Experiment... 10 6.1. Column Startup... 10 6.2. EXERCISE 1: Time Required for Reaching Steady State Condition... 10 6.3. EXERCISE 2: Efficiency vs. Vapor velocity... 11 6.4. Column Shutdown... 12 6.5. Data Processing... 12 6.6. Lab Journal... 12 7. Report... 13 7.1. What Your Report Should Contain... 13 7.2. Common Mistakes (Read carefully and take it into account)... 14 Bibliography... 15 A. Assignment... 16 B. Composition Measurements... 17 Pycnometers... 17 Gas Chromatography (GC)... 18 Sampling... 18 Using Micropipettes... 19 Running Samples... 20 Vial Disposal... 21

1. Objectives The purpose of this laboratory work is to understand and investigate the distillation principles, the parameters affecting the operation of distillation columns and how to find optimal operating conditions. Three tasks should be done in the lab: 1. to determine time required to reach steady state condition; 2. to determine the efficiency of a column as a function of the vapor velocity; 3. to determine the flooding and weeping conditions of the column This is a list of documents that are expected to be delivered: 1. A photocopy of your lab journal (see description in the section 6.4); 2. Work Plan (see description in the section 5.1); 3. Report (see description in the section 8) Note that the main purpose of the report is to show that you have learned and understood the objective behind the three tasks given in this experiment.

2. Required Knowledge/Support Literature You should read/ know: Definition of flooding and weeping point Theory behind McCabe-Thiele s method Ability to apply McCabe-Thiele s method in an exercise Understanding of how an operating line changes with reflux ratio Ethanol-water density-composition data at 25 o C from Perry s handbook (2008). You should read the HMS booklet thoroughly, and sign it. There are copies in English available at the Department office. This has to be done by every student before you are allowed to work in the lab. Before the experiments, you MUST: Fill in the equipment card (Apparaturkort) for the experiment, and it should be signed by your supervisor as well as by at least one student per group. This is important as it grants you authority to work in the lab. Fill a Chemicals fact sheet (Kjemikaliekort) with data you are supposed to know about any chemicals you are going to use. In this experiment, you will need ethanol and distilled water Fill the Hazardous activity identification form. (This is uploaded in the website of the course) Calculate the amount of ethanol (96 vol%purity) and water needed in order to prepare your start solution (see section 6) Submit the work plan (see section 5) to your supervisor at least 3 days before the experiment. Required reading before doing the experiment: 1. Geankoplis (2003): This book is required for basic distillation theory, Chapters 11.1-11.5 2. King (1971): This book is required to read about the definitions of weeping and flooding points 3. Gmehling and Onken (1977): This book is required for getting the data for Vapour-Liquid Equilibrium (VLE) 4. Perry and Green (2008): This book is required to get the data for weight percentage of ethanol as a function of density

For those who are interested in learning more about these topics, a more complete list of literature is suggested: 1) Theoretical Background Material a) General distillation theory: i) Geankoplis (2003) ii) Lydersen (1983) iii) Terjesen and Lydersen (1958) iv) Perry and Green (2008) v) McCabe and Smith (1976) b) Definitions of weeping and flooding points: i) Lydersen (1983), ii) King (1971), iii) Traybal (1980). 2) Data and Constants a) Equilibrium data: Gmehling and Onken (1977) b) Weight percentage of ethanol as a function of density: Perry and Green (2008), Handbook of Chemistry and Physics. 3) Similar Experiments in the Literature a) McCabe and Smith (1976), b) Perry and Green (2008), c) Lydersen (1983).

3. Brief Theory 3.1. Definitions Distillation is a process of physically separating a mixture into two or more products that have different boiling points, by partial vaporization of a liquid mixture and/or by partial condensation of a gas mixture thereby rendering liquid phase richer in less volatile (with higher boiling point) component and the vapor phase is richer in more volatile (with lower boiling point) component. Weeping point: refers to a condition when the vapor velocity through the perforations of a tray is so low that the liquid can t be held out of the perforations and instead of overflowing over the downcomer, the liquid weeps through the perforations/holes of a sieve tray. The vapor at this point loses contact with the liquid. This definition does not apply to packed columns. Flooding point: any countercurrent separation device has a capacity limit. This limit in distillation is the known as flooding and is a result of high vapor velocity. At high vapor velocities, the pressure exerted by the vapor from below balances the gravity head of the liquid, as a result liquid starts building up in the column. This condition is reflected by sudden increase in the pressure drop. Column efficiency: the overall column efficiency in a distillation column is defined as the ratio of total number of ideal equilibrium stages to the number of actual trays in the column. An ideal distillation stage is one in which the outgoing liquid and vapor phase establish an equilibrium with each other. High column efficiency indicates a thorough contact between gas and liquid. In case of packed column, for the estimation of number of actual trays we use the height equivalent to a theoretical plate (HETP). HETP is the height of packing that does the same separation as a theoretical plate. Examples: A. Consider a tray column with the following characteristics: Number of theoretical stages (by McCabe Thiele diagram), N t = 9 Number of actual trays, N a = 10 Hence, the column efficiency is given by: Note that one stage is deducted from the numerator, as the reboiler is counted as one stage.

B. Consider a packed column with the following characteristics: Number of theoretical stages (by McCabe Thiele diagram), N t = 9 Height of packing = 1.3 m Hence, the HETP is given by: m Reflux: the portion of the vapor that is condensed and then returned to the distillation column. In this laboratory work most of time the distillation column will work with a total reflux, i.e., the entire vapor at the top of the column is condensed. McCabe Thiele Method: the simplest and perhaps most instructive method for analysis of binary distillation is the graphical approach presented by McCabe and Thiele in 1925. This method is based on the constant molar overflow assumption, which implies constant molar vapor flow rate and constant molar liquid flow rate leaving all stages in a section. Hence in each section of a distillation column, the operating line can be considered a straight line.

4. Equipment The following Figures highlight the main components of the equipment to be used. It is advised that you visit the lab and identify these parts when writing your working plan. Figure 4.1.: Sieved-tray column

Figure 4.2.: The different column tray types

5. Planning the Experiment After reading this description, study the literature and make sure that you understand the process and the theoretical background. Make sure that you understand the McCabe-Thiele method. A brief overview of distillation theory and McCabe-Thiele must be included in the work plan, but do not include parts which are not of relevance to your exercise. Go to the lab and study the column. Locate every part marked on the apparatus description. Find the literature data you need. 5.1. Writing the Work Plan The work plan should be delivered to your supervisor not later than 3 days before you make the experiment. A group will not be admitted to work on the experiment without having delivered the work plan. The work plan should include information on: How to do the experiment; How to calculate results from the raw data (See Appendix A). Your raw data will consist of composition of product (from analysis of your samples), and time. You will have to calculate: Composition of top and bottom products Number of ideal trays needed Vapor velocity A part of the work plan will be to do the Assignment exercise shown at the end of this document in the Appendix A. Include in your work plan a filled and signed equipment card (Apparaturkort) and the necessary chemicals fact sheets (Kjemikaliekort).

6. Experiment You will run two different exercises: EXERCISE 1: time required for reaching Steady State condition EXERCISE 2: Efficiency vs. Vapor velocity Generally the experiment takes from 6 to 8 hours 6.1. Column Startup 1. Turn on the PC 2. Turn on the cooling water 3. Make sure that that the bottom and distillate tap lines are closed 4. Charge the column with 5800 ml a mixture of water and ethanol as follow: Raschig-ring column: x ethanol =0.1 Sieve-tray column: x ethanol =0.12 Oldershow perforated plate: x ethanol =0.11 5. Set the column to total reflux Using the control box, set T = 105 o C When the top temperature substantially changes, or the pressure difference over the column rises quickly, set the boiler s power duty as follows: Raschig-ring column 50%, Sieve-tray column 40%, Oldershow perforated plate 50%. 6. Wait until the vapor stream starts condensing: let this be zero time. In case of flooding conditions, switch off the heater immediately. In any emergency situation, turn off the heater but leave the cooling water on. 6.2. EXERCISE 1: Time Required for Reaching Steady State Condition The purpose of this exercise is to calculate how long the column takes to reach a steady state conditions: 1. Set the reboiler power to a desired value (say 50%) and wait until the column starts to give condensate 2. Take samples from the top every 5 minutes within 1 hour, so in the end of this experiment you will have 12 top-samples

3. After you take the sample number 12, take one sample from the bottom of the column, because you will need its composition for the next exercise 4. Analyze all samples and find out how long the column takes to reach steady state: when the composition of the top-samples is constant from one sample to another, you can consider that you reached the steady-state 6.3. EXERCISE 2: Efficiency vs. Vapor velocity The goal now is to find how the column efficiency (or the theoretical number of trays from McCabe- Thiele) varies as a function of the vapor velocity. Run the column with total reflux for five different boiler powers, yielding different vapor velocity. 1) Set a desired power (say, 40%) in the reboiler 2) Wait until the column reaches the steady-state. You can assume that the column reaches steady state conditions in the same time as in the exercise 1. For example, if in the exercise 1 you got the constant density of the top-samples in 40 minutes, you can consider that in exercise 2, the column reaches the steady-state also in around 40 minutes 3) Take samples from the top and from the bottom, 20 ml each 4) Write down the reflux rate at the time of sampling 5) Set a new power in the reboiler. In total, you should get 5 different velocities using 5 different boiler power settings Analyze samples and calculate the efficiency of the column and the theoretical number of stages using McCabe-Thiele To calculate the vapor velocity, use the following equation: where: is the volume rate of the gas, [m 3 /s]. It can be calculated from the equation of state of the ideal gas; A is the cross-sectional area of the column, [m 2 ]. You can calculate it using diameter D of the column, given below: Oldershow column: D = 0.07 m, Sieve-Tray column: D = 0.05 m, Packed column: D = 0.05 m. Identify flooding and weeping points at the end. Record the considering the values of pressure drop and vapor velocity at flooding and weeping point. Write down the power of the boiler at the weeping and flooding points. The weeping point is not applied to the packed column.

6.4. Column Shutdown 1. After taking the last needed sample, turn off the heater 2. Let the column with contents cool down 3. Empty the column and turn off the cooling water 4. Turn off the rest of the equipment 6.5. Data Processing When you have finished in the lab, you have to analyze the data. If you are using picnometers to determine the sample densities, then Literature data will be needed on how does the density varies with the composition for the water-ethanol system. With that, you can derive your sample s composition. From the GC analysis, you will get the composition of your samples directly. A detailed description on how to proceed with the analysis is given in Appendix B. Then you must draw McCabe-Thiele diagrams to find the number of ideal trays. You may use a computer program to draw the McCabe-Thiele diagrams. If you program it yourself (for example, in Matlab) you should also include the program code as an appendix in your report. However, at least one diagram should be drawn by hand. Use mm-scale paper in A3 format. Remember to draw the equilibrium line as accurately as possible. 6.6. Lab Journal While conducting experiments you will have to maintain a lab journal. In this journal you will write all your raw measurements, that is, before any calculation. This will help you to spot errors, and provides a data backup. It is wise to make notes on anything worth noting, as Flooding conditions reached, Error in valve operation, run must be repeated, Unknown failure, all ethanol seems gone, Bad measurement, possible cause is.... It is recommended to prepare the journal before starting the lab, with tables ready to be filled in and memos. This will help you remembering what measurements to take and when: you would not be the first students that get halfway through the day only to realize they did not write some important data, and must start from scratch. Make sure to account for all the data you have to collect.

7. Report 7.1. What Your Report Should Contain For general guidelines in writing the report, refer to the lab course s home page. Below are given some tips for the distillation experiment, as follows: Introduction part, where you should explain what the goals of the experiment. Theoretical part, where you should describe the main information about the distillation process in a concise way Explain in the theoretical part how the operation line should look in the McCabe-Thiele diagram at total reflux Describe the procedure clearly, including all relevant details Include the description how you made exercises 1 and 2, with calculations and plots: for exercise 1 a plot of top-samples composition vs. time (12 points); for each power duty a plot of total column efficiency (HETP) vs. vapor velocity; McCabe-Thiele diagrams of mole fraction in liquid phase vs. mole fraction in gas phase, separate for each power duty (total: 5 plots) One McCabe-Thiele diagram should be made by hand, on the mm-scale paper in A3 format. Write the conclusion and obtained results of both experiments, including the flooding and weeping points, discuss the time required to reach the steady-state condition, describe the tendency of the change of the vapour velocity versus heater s power and column efficiency. In a separate Discussion part give a description on the possible error sources in your experiment. In this section calculations are not required. If your results do not relate to the theory, try to come up with a reasonable explanation (also you can discuss these things with your supervisor). A photo copy of the lab journal shall be handed in as an appendix to the report. This will make evaluation of your work routines easier and will also make it simpler to figure out the reason when some results seem strange. You ll send a first version of the report to your instructor, who will correct it and give it back to you with comments to help you improve your report. The final version of the report will then be evaluated. Note: For typesetting guidelines, see Beccari (1997).

7.2. Common Mistakes (Read carefully and take it into account) Work plan not delivered in time (at least 3 days before the experiment itself). Group will not be admitted to work on experiment without delivered work plan. Incomplete listing of results in abstract or conversely too long-winded abstract. Too much theory, covering parts that are not necessary. Incomplete description of the methods: they must be clear and thorough enough that another group might run the same experiments you did only reading that. Results presented with the wrong parameters (e.g. plots of efficiency vs. heater s power instead of vapor velocity). Not mentioning units of calculated or measured values. Write both in the Work Plan and in your Report. Wrong units used in plots and calculations (wrong ideal gas constant s unit or wrong temperature unit, and so on). Not mentioning the name of axes in the plots, including the units of plotted values, and write on the McCabe diagrams the mole fraction of top and bottom composition. Aberration in the results is possible, try to explain them in your report, based on your experiment procedure. Incomplete appendices: remember to attach all relevant material, especially the lab journal with raw data, and any computer scripts/programs you have written. Please avoid making this list longer for next year s students!!

Bibliography Beccari, C. (1997). Typesetting mathematics for science and technology according to iso 31/xi. TUGboat 18 (1). Geankoplis, C. J. (2003). Transport Processes and Separation Process Principles (4 ed.). Prentice Hall. Gmehling, J. and U. Onken (1977). Vapor-Liquid Equilibrum Data Collection: Aqueous-Organic Systems (Vol. 1, Part 1). Dechema, Germany. King, C. J. (1971). Separation Processes. McGraw-Hill, USA. Lydersen, A. L. (1983). Mass Transfer in Engineering Practice. JohnWiley&Sons, Ltd. McCabe, W. L. and J. C. Smith (1976). Unit Operations of Chemical Engineering (3ed.). McGraw-Hill, USA. Perry, R. H. and D. W. Green (2008). Perry s Chemical Engineers Handbook (8 ed.). McGraw-Hill, USA. Terjesen and Lydersen (1958). Kjemiteknikk II. Trondheim. Traybal, R. E. (1980). Mass-Transfer Operations (3 ed.). McGraw-Hill, USA.

A. Assignment To make sure you understand how to calculate your results, you should make an example calculation, and deliver it in your work plan. You have the following measurements: Weight of empty pycnometer 1-11.98170 g. Weight of empty pycnometer 2-11.77385 g. Weight of pycnometer 1 with water - 16.95955 g. Weight of pycnometer 2 with water - 16.75745 g. Weight of pycnometer 1 with distillate - 16.0903 g. Weight of pycnometer 2 with bottom product - 16.6962 g. From the GC analysis, you have the following measurements: Distilate composition: x ethanol = 0.744 Bottom composition: x ethanol = 0.033 Show that both methods lead to approximately the same results. Calculate the vapor velocity, knowing that the column was operation under total reflux, and the reflux rate was 53 ml/min. All measurements were done at 25 C and 1 bar. Calculate the following: Vapor velocity in m/s. Estimate of the number of ideal stages (McCabe-Thiele) and attach the plot of this diagram to your work plan. Beside these calculations, it is necessary to include some theory about Gas Chromatography (we use FIR sensors). Explain how we can calculate the ethanol concentration with GC (the quantitative analysis by using an internal standard).

B. Composition Measurements The composition measurement is done either with pycnometers or with Gas Chromatography (GC). The following sections include the information needed to the procedure. Pycnometers The composition of ethanol water system at a given temperature is uniquely related to the density. This data for ethanol water system at 25 C can obtained from Perry and Green (2008). Thus composition of the samples can be determined by measurement of their densities using pycnometers. Each pycnometer and its cap are numbered. The number on the pycnometer and the number on the used pycnometer s cap should be the same. Pycnometers are a simple tool, but they require some care to get correct results: in the beginning of the experiment you should calibrate pycnometers with distilled water at 25 C, to obtain their exact weight and volume. This is done by first weighing the empty pycnometer, and then weighing the pycnometer filled with distilled water; the samples taken from the column should be cooled to a temperature about 25 C, and need to be covered with a plastic film during cooling to avoid evaporation; after you place your sample into pycnometer be sure that there is no air bubbles inside the pycnometer, otherwise the measurement will be wrong; be sure that before you weight the pycnometer, you have dried it properly from outside as well; after you have used the pycnometer, before next use, wash it with distilled water and dry it with compressed air; At the end of the experiment, wash the pycnometers with distilled water and place them for drying with their caps removed. It is recommended that all the measurements are done by the same person to reduce error in measurements.

Gas Chromatography (GC) This section includes the information needed to measure the composition by Gas Chromatography (GC). More information about how GC works can be obtained by searching in the internet. Sampling The needed equipment is shown in Figure 7.2. To determine the ethanol content, the ethanol sample must be mixed in a fixed ratio with a standard component (in this case, isopropanol). Pour isopropanol into a small glass container (you will probably not need more than 5 ml). Figure 7.2 Equipment for sample preparation To prepare a sample for the GC, mix the following volumes into a glass vial by using the micropipettes: 500 μl of ethanol sample 250 μl of isopropanol When pipetting, use the reversed pipetting technique (see the subsequent section). Seal the vial with a cap. If the vial has a screw top use screw caps. If the vial has a crimp top, use the aluminum cap and crimp it on using the crimper. Remember to clearly mark the vial for later identification.

Using Micropipettes The micropipettes use air displacement to dispense the liquid. To use the pipette, first attach a disposable tip (make sure the tip is fasten firmly, such that there is no air leakage). The pipettes have fixed dispensing volumes, and the quantity is market on the top button (plunger). The plunger has three steps (stops) when pushed down: First stop: used for aspirating and dispensing liquid into and out of the tip. Second stop: used to blow-out the remaining liquid from the tip. Third stop: detaches the disposable tip. Reversed pipetting technique The pipetting will be done in 5 steps: 1. Wetting 2. Aspiration 3. Dispensing 4. Blow-out 5. Tip-release See Figure 7.3. Figure 7.3 Pipetting diagram Wetting and Aspiration First submerge the tip about 3 mm into the liquid, push the plunger down to the second stop, release the plunger slowly, push it down to the second stop again, and slowly release. The first aspiration and displacement step is done to wet the tip and increase the accuracy. Dispensing, Blow-out, and Tip Release Hold the tip at an angle against the glass wall, and dispense the liquid into the glass vial by pushing the plunger down to the first stop. Hold the plunger at the first stop, and lift the tip out of the vial. Blow out the remaining liquid into a glass container marked for waste by pushing the plunger down to the second stop. Release the tip into the trash by pushing the plunger down to the third stop.

Running Samples Place the prepared samples into the auto sampler tray. Take note of the position of the respective samples. Start the Chrom-Card program by double clicking in the desktop icon. Double-click the Focus #1 GC icon. Enter the sample information. Do this by first opening the sample table (edit sample table, or click on the icon). There are several fields that need to be filled in for each sample you want to run. ID: The sample identification number (gray area). In the white area next to it, you will have to set the active sample. The active sample is the sample that the GC will analyze. If there are more samples in the sample table under the active sample, then the GC will analyze them in incrementing order after finishing analyzing the active sample. Therefore, you will set the active sample as the first sample you want to analyze. Sample name: Here you put in a sample name for your samples. This should have some logic structure (e.g. the extraction time of the sample and which fraction, like T_5min). Filename: The results will be stored in a file with this filename. This name must start with your group number (e.g. B01_T_5min) to ensure no other group overwrites your data Type: Here you tell the GC if the sample will be used for calibration or if it is an unknown sample. In the distillation experiment, all the samples will be unknowns. S.A., I.S., and X.F: You do not need to fill in the fields. The GC method filename: C:\Focus\June 2011\ethanol.gsm The AS method filename: C:\Focus\June 2011\ethanol.asm These settings (method) will be sent to the GC, and the GC will use these settings until receiving new settings. Therefore, you will only need to fill in method fields for the first sample you run. For all subsequent samples, these fields can be left blank. Vial: This is the samples position on the auto sampler tray. It is important that you enter the correct position. Else, you will analyze the wrong sample. When all the samples have been entered into the sample table, push OK and you will return to the main window (Focus #1). When you are ready to start analyzing the samples, push the button with the green arrow. You will get a save method dialog. Save the method as ethanol.mth (You will get an overwrite dialog, push OK). A start run dialog will appear, push START.

The GC will then analyze the active sample and all subsequent samples. The processing time of one samples is about 4 min. To watch the chromatograms as the samples are being analyzed go to View Sample Being Acquired or push shift+f1. When all your samples have been analyzed, you can find the results at Reprocessing Summarize results. Here the ethanol content of the samples are given in volume fraction (0.010 vol%). For the report, you will need to print out the GC analysis report. In the summarized results, group your samples by entering your group number into the group field (This is to ensure that there is no duplicate grouping. If there are samples in the summarized results with the same group number, choose a different three digit number for your samples). Mark one sample in your sample group, and push print. Print it out on paper, and use it as an appendix in your report. The computer is connected to the printer in K4, 2nd floor in the kitchen area. If the printer does not work, print the results to a.txt file for later printing. Vial Disposal When you are finished analyzing the samples, take your vials out of the auto sampler tray. Before disposing the vials, remove the caps (if you are using crimp top vial, use the decapper to remove the cap), and empty the contest of the vials into the container marked for organic waste. The vials are discarded into the glass waste basket, and the caps are discarded into the waste basket.