Tridak Model 1050 User Guide

Similar documents
Tridak Model 1060 User Guide. Syringe Filling System

Model 300 Dispensing Systems. Systems User Guide

Techcon Systems TS1258 Pressure Pot

ABRASIVE REGULATOR II

RhinoPro Cartridge Gun Manual

SomnoSuite FAQ. Setup. Calibration 4. What are the calibration requirements for the SomnoSuite? Settings

Techcon Systems TS1254 Pressure Pot

ABRASIVE REGULATOR II

Pressure Dump Valve Service Kit for Series 2300 Units

NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE

EASTERN ENERGY SERVICES PTE LTD. 60 Kaki Bukit Place #02-19 Eunos Tech Park Singapore, SG Singapore Telephone: Fax:

Adjustable. Unloader Valve. O&M Manual. Part #

NOVALYNX CORPORATION MODEL RAIN GAUGE CALIBRATOR INSTRUCTION MANUAL

Pneumatic Powered - Plunger Pumps

5 Gallon EVkeg Operation Manual

TECHNICAL DATA. Q = C v P S

PDY TON HYDRAULIC CRIMPING TOOL WARNING

2K 600mL Dispense Guns with Built-In Retainers

Instruction Manual. PE-25/32/37 Tapping Machines. POLYTAPP Valves

5 Gallon Pressure Pot with HVLP Spray Gun and Hose

Instruction Manual Updated 7/26/2011 Ver. 2.2

TECHNICAL DATA. Q = C v P S

WARNING: READ THE GENERAL INFORMATION MANUAL INCLUDED FOR OPERATING AND SAFETY PRECAUTIONS AND OTHER IMPORTANT INFORMATION.

HYDRAULIC CYLINDER TEST

RG1200 Service and Repair Manual

Pressure Dump Valve Service Kit for Series 3000 Units

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Q = C v P S

MyControl Bathing System Signature Series

TECHNICAL DATA. Q = C v P S

REV0709. Parts List. Hydraulic Cylinder Model MODEL C SINGLE-ACTING, SPRING RETURN HYDRAULIC CYLINDER. Max. Capacity: 55.2 Tons at 10,000 PSI

TWO POST RAM PACKAGE 5 GALLON READ THIS MANUAL CAREFULLY BEFORE INSTALLING, OPERATING OR SERVICING THIS EQUIPMENT.

TECHNICAL DATA. Q = C v P S

Installation and Service Manual

XpressFill XF2500 Counter Pressure Filler. Operating Instructions

MODEL 840 AIR HYDRAULIC PUMP INSTRUCTION

Paintball Marker. User s Manual. 530 South Springbrook Road Newberg, OR 97132

PROPORTIONING VALVE. Model 150 INSTRUCTION MANUAL. March 2017 IMS Company Stafford Road

Model 7989T Steel Pipe Squeezer Sch. 40 & Sch. 80. Operations Manual

Installation, Operation and Maintenance Manual for Back Pressure Regulator

Suggested Installation & Operating Instructions for Sidewinder Pumps

Operating Procedure TITON SUBSEA BOLT TENSIONER

Discontinued. Powers Controls. Technical Instructions Document No P25 RV Rev. 1, May, RV 201 Pressure Reducing Valves.

MANUAL BE SERIES Test Benches

OWNER S TECHNICAL MANUAL

Pressure Injection Cell Operator s Manual

Sample Concentrator SBH CONC/1 Instructions for use

Model PSI Compressor with 3-Gallon Air Tank 12VDC

Welker Sampler. Model GSS-1. Installation, Operation, and Maintenance Manual

Loctite EQ VA25 Dispense Valve 50 Bar IDH Number EQUIPMENT Operation Manual

TECHNICAL DATA. Q= Cv S

P5513. Users Manual. Pneumatic Comparison Test Pump. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.

FOR INSTALLING CO 2 BLENDER KIT (P/N IN BEER SYSTEM

DISPENSING VALVE MODEL VDP100 INSTRUCTION MANUAL

!!!! SERVICE MANUAL PRESSURE POT 2 GALLON. Service Manual: LT Washington St 931 Progress Ave., #7

Installation of Your SprayMaster System

THE HF-300 SERIES. Operating and Service Manual. Series includes all variants of HF-300/301

299H Series. Introduction. P.E.D. Categories. Specifications. Installation. Warning. Installation Guide English September 2012

TWO POST RAM PACKAGE 55 GALLON

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

Installation and Use Manual

OPERATION MANUAL NTF-15

Misaligned Folds Paper Feed Problems Double Feeds Won t Feed FLYER Won t Run iii

DK ton, Double-acting, Die-type Crimping Tool

Operation Manual Piston Sensed Gas Pressure Regulators

TECHNICAL DATA 3 MODEL G-3000 DRY VALVE RISER ASSEMBLY

PANACEA P100 LOW PRESSURE USER MANUAL

OPERATION MANUAL NTF-60 Plus

OPERATING INSTRUCTIONS

Tube Tugger. Operating and Maintenance Instructions. Semi-Continuous Tube Extractor.

Binks SG-2 Plus TM 2 QT. PRESSURE CUPS Model No (Standard) Model No (with OscillatingAgitator)

20 Ton SD Shop Press Operating Instructions

Bray/ VAAS O-Ported Series Knife Gate Valve 770/780 Series Operation and Maintenance Manual

The NAMIC Dream Kit. Single Operator Control. Reduce Contrast Waste. Less Force to Inject. Compensator * Manifold. How the Compensator Manifold Works:

TECHNICAL DATA Q = C. v P S. 2 Model G-2000 Dry valve. Page 1 of 13

ROUGHNECK II Pumpless Drain

INSTALLATION, CARE & USE MANUAL. EMASMB & LMASMB Surface Mount Bottle Filling Stations

AIR/OVER HYDRAULIC JACK 20 TON

TECHNICAL DATA OBSOLETE

RS(H)20, 25 USER MANUAL

Hydraulic Punch Drivers

REL-510H WARNING NOTICE 12 TON SINGLE ACTING REMOTE HYDRAULIC CRIMPING HEAD

SPECIFICATIONS Type: Twin stack, single phase Tank: 4 gallon Air Output: PSI; PSI Max PSI: 125 PSI HP: 1.

ACCUMULATOR OPERATING & MAINTENANCE INSTRUCTIONS

1. CONDITIONS FOR USE 2. SAFETY

75 Ton SD Shop Press Operating Instructions

Operation Manual Guillotine Cutter RC-5

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly.

PRS(TC)4,8 USER MANUAL. Read the complete manual before installing and using the regulator.

INSTALLATION INSTRUCTIONS. CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION

THE MF-400 SERIES. Operating and Service Manual. Series includes all variants of MF-400/401

TABLE OF CONTENTS SAFETY FIRST!...3 BASIC OPERATION...4 ADJUSTMENTS...5. Cocking Pressure...5. Three-Way Valve Adjustment...6

30T A/Manual Hydraulic Shop Press

DBML-60/80 Squeeze Tool

Santa Fe Cycles Assembly Guide Introduction

Rev. A Jul 07 Part # SS VD510-SS INSTRUCTION MANUAL DISPENSING VALVE MODEL VD510-SS INSTRUCTION MANUAL

REL-46 WARNING NOTICE 15 TON SINGLE ACTING REMOTE HYDRAULIC CRIMPING HEAD. Compatible with RELIABLE R15 and P Style dies. REL-46 Manual

Rev. B Sept 06. VD510 INSTRUCTION MANUAL Part # DISPENSING VALVE MODEL VD510 INSTRUCTION MANUAL

LRS(H)4 Pressure-Reducing Regulator User Manual

TABLE OF CONTENT IMPORTANT HPA AIR TANK SAFETY INSTRUCTIONS AND GUIDELINES RYSE ON/OFF ASA GETTING STARTED O-RING LIST SCREW LIST MICRO SQ BOARD

Transcription:

Tridak Model 1050 User Guide Syringe Filling System Instructions for Safe Use Setup and Operation Maintenance Ordering Spare Parts and Accessories

2 Tridak Model 1050 Syringe Filling System User Guide About Dymax Light-curable materials as well as systems for light curing, fluid dispensing, and fluid packaging. Dymax manufactures a wide variety of light-curable oligomers, adhesives, and coatings as well as a complete line of manual and automatic fluid dispensing systems, light-curing systems, and fluid packaging equipment. Our Tridak brand fluid packaging systems are designed for use in numerous industries, including industrial, medical, dental, pharmaceutical, and food preparation. These filling systems provide significant productivity gains over manual and other more complicated and costly filling methods. The equipment is suited for all industry standard packaging as well as custom molded syringes and cartridges. We also possess the capability to fabricate nozzles and multi-port dispensing manifolds that perfectly match the packages being filled. Single- and dual-component materials can be packaged in seconds, one at a time, or in multiples for higher volume throughput. The equipment accommodates various mix ratios. High-pressure filling equipment is available for packaging highly filled materials in tiny syringes or compoules. Please note that most filling system applications are unique. Dymax does not warrant the fitness of the product for the intended application. Any warranty applicable to the product, its application and use is strictly limited to that contained in the Dymax standard Conditions of Sale. Dymax recommends that any intended application be evaluated and tested by the user to insure that desired performance criteria are satisfied. Dymax is willing to assist users in their performance testing and evaluation.

Tridak Model 1050 Syringe Filling System User Guide 3 Contents Introduction... 4 Introduction to the User Guide... 4 Where to Get Help... 4 Safety... 4 General Safety Considerations... 4 Specific Safety Considerations... 4 Personal Protective Equipment... 5 Product Overview... 5 Description of the Model 1050 Syringe Filling System... 5 Special Features and Benefits of the Model 1050... 5 Description of Main Components... 6 Assembly and Setup... 7 Unpacking and Inspecting Your Shipment... 7 Parts Included in the Model 1050 Syringe Filling System... 7 Utilities Required... 7 Preparing the System for Use... 8 Install the Reservoir Support... 8 Install the Material Reservoir... 8 Connect the Material Reservoir Pressure Supply Tube... 9 Operation... 10 Preparing the Cartridge... 10 Loading the System... 11 Pressurizing the System... 14 Depressurizing the System... 14 Set the Fill Amount for the Syringe Size... 14 Priming the System... 15 Prepare the Syringes... 15 Fill the Syringe... 15 Model 830 Valve Adjustments... 16 Cleaning and Maintenance... 16 System Cleaning... 16 Spare Parts and Accessories... 17 Replacement Parts/Accessories... 17 Specifications... 18 System Specifications... 18

4 Tridak Model 1050 Syringe Filling System User Guide Introduction Introduction to the User Guide This guide describes how to assemble, use, and maintain the Model 1050 Syringe Filling System filling system safely and efficiently. Intended Audience We prepared this user guide for experienced process engineers, technicians, and manufacturing personnel. If you are new to filling systems and do not understand the instructions, contact Dymax Application Engineering to answer your questions before using the equipment. Where to Get Help Additional resources are available to ensure a trouble-free experience with our products: Detailed product information on www.tridak.com Customer Support and Application Engineering teams are available in the United States, Monday through Friday, from 8:00 a.m. to 5:30 p.m. Eastern Standard Time. You can also email us at info@dymax.com. Please see the back cover of this user guide for worldwide contact information. Safety WARNING! If you use this filling system without first reading and understanding the information in this user guide, injury can result. To reduce the risk of injury, read and ensure you understand the information in this user guide before assembling and operating a Tridak filling system. General Safety Considerations All users of Tridak equipment should read and understand this user guide before assembling and using the equipment. Specific Safety Considerations Using Safe Operating Pressures Pressurizing the components in the dispensing system beyond the maximum recommended pressure can result in the rupturing of components and serious personal injury. To minimize the risk of rupturing components and injury, do not exceed the maximum operating pressure of the components in your filling system. (See system specifications on page 18)

Tridak Model 1050 Syringe Filling System User Guide 5 Preventing Injection Injury Discharging fluids or compressed air with a dispensing tip against your skin can cause very serious injection injury. To minimize the risk of injection injury, do not place the dispensing tip in contact with your skin. Personal Protective Equipment Operators are recommended to wear any personal protective equipment specified by their company s safety policy for the materials used during filling. Personal protective equipment should be in place and used at all times before pressurizing the system and when handling any potentially hazardous materials. Product Overview Description of the Model 1050 Syringe Filling System The Model 1050 syringe filling system is designed to quickly fill plunger-style syringes, one at a time, quickly and accurately from a material reservoir. The system can be used with a number of different material reservoirs including cartridge reservoirs, bottle reservoirs, and pail reservoirs. The system utilizes a Model 830 disposable fluid path valve to make material changeover fast and easy, while eliminating most crosscontamination. The disposable fluid path can be fitted with a series of adapters to fill Luer-Lock and Oral tip syringe types. Special Features and Benefits of the Model 1050 This machine features several design features to make filling simple, quick and clean, including: Disposable fluid path valve with disposable wetted parts that eliminate material contamination and minimize clean-up and maintenance Disposable fluid path can be capped and remain attached to the material cartridge for storage Adjustable suck-back feature allows for a clean dispense of stringy and tacky materials Material reservoir pressure regulator to control the reservoir pressure used for filling Fills various syringes including 0.5, 1, 3 and 5 ml (up to 60 ml) syringes with pre-inserted plunger; tooling nozzles are available for both Luer Lock or Oral tips. Adjustable pneumatic stop assures accurate fills Foot-switch for hands-free fill cycle activation Small footprint; Dimensions (L x W x H) 23.6 in x 12 in x 25 in (60 cm x 30.48 cm x 63.50 cm)

6 Tridak Model 1050 Syringe Filling System User Guide Description of Main Components The main components in the Model 1050 Syringe Loader filling system include: 1. Air Regulator The air regulator enables you to precisely control the air pressure in the fluid reservoir. The air precision regulator includes: a. Pressure gauge that displays the pressure in the fluid reservoir. A 0- to 100-psi (0- to 6.9-bar) pressure gauge is installed on the air regulator. b. Pressure control knob that enables you to adjust the pressure of the air entering the reservoir. 5-60 psi recommended for most applications. 2. Compressed Air Line The air line consists of blue polyurethane tubing designed for compressed air use. 3. Model 830 Valve A disposable fluid path valve used to dispense material from the material reservoir. This valve features suck-back, allowing drip-free dispensing from fill-to-fill. 4. Fluid Path The fill tube and fittings used to deliver fluid material from bulk cartridges to syringes. It is constructed of black, light-blocking polyethylene tubing compatible with many types of commercial and medical fluids. 5. Tube Support Supports the disposable fluid path during dispensing and allows the valve pistons to compress the fluid path as needed to control fluid flow and suck-back. 6. Reservoir Retainer or Reservoir Tank The reservoir retainers and tanks hold fluid reservoirs. Reservoir retainers accept cartridge reservoirs. Reservoir tanks accept bottle and pail reservoirs. Figure 1. Main Components of the Model 1050 Syringe Filling System Material Reservoir Support Material Reservoir Pressure Supply Model 830 Dispensing Valve Flow Control Disposable Fluid Path Air Regulator Compressed Air Line Inlet (60-90 psi) Foot Switch Tube Support Assembly Valve Mounting Screw Fill Stop

Tridak Model 1050 Syringe Filling System User Guide 7 Assembly and Setup Unpacking and Inspecting Your Shipment When your system arrives, inspect the boxes for damage and notify the shipper of box damage immediately. Open each box and check for equipment damage. If parts are damaged, notify the shipper and submit a claim for the damaged parts. Contact Dymax so that new parts can be shipped to you immediately. The parts listed below will be included in your shipment. If parts are missing, contact your local Dymax representative or Dymax Customer Support to resolve the problem. Parts Included in the Model 1050 Syringe Filling System Model 1050 with Foot Switch [1] Tube Assemblies Luer Female [2] Reservoir [3] Rod Assembly [4] Airline Kit for Reservoir and Model 1050 [5 & 6] Allen Key Kit [7] 0.32 Bleed Wire with Pull Ring [8] Model 1050 User Manual [9] Stopper Pin (for use with plunger-less syringes) [Not Shown] Figure 2. Unpacking Diagram Utilities Required AIR: Clean, dry, non-lubricated air operating pressure of 60 90 psi

8 Tridak Model 1050 Syringe Filling System User Guide Preparing the System for Use Install the Reservoir Support 1. Place the reservoir support on top of the screw hole in the left side of the system base. 2. Using the screw and washer provided, place screw up with the washer through hole in base and attach to reservoir support. Tighten the screw until the reservoir support is secure (Figure 3). Figure 3. Reservoir Support Installation Install the Material Reservoir 1. Slide the Material Reservoir Retainer (Figure 4, D) over the top of the Reservoir Support (Figure 4, B). 2. Position the Material Reservoir Retainer on the Reservoir Support so that the bottom of the Retainer is approximately 2 inches above the top of the Back Plate. 3. Using the Height Adjustment Handle (Figure 4, C), tighten the set screw until the Material Reservoir Retainer does not move.

Tridak Model 1050 Syringe Filling System User Guide 9 Connect the Material Reservoir Pressure Supply Tube 1. Connect the material reservoir s Pressure Supply (Figure 4, F) to the Air Regulator (Figure 4, G). 2. Connect the opposite end of the Material Reservoir Pressure Supply to the Material Reservoir Air Inlet. NOTE: If your system is using a cartridge retainer, the Material Reservoir Air Inlet (Figure 4, A) is located in the center of the cartridge retainer s cap. Figure 4. Syringe Filler with 20 oz Cartridge Retainer (Rear View) B Reservoir Support A Material Reservoir Air Inlet C Height Adjustment Handle F Material Reservoir Pressure Supply D Reservoir Retainer G Air Regulator E Fluid Path H System Pressure Inlet

10 Tridak Model 1050 Syringe Filling System User Guide Operation Preparing the Cartridge 1. Place pre-packaged, sealed cartridge upright on a flat, stable working surface (Figure 5). 2. With the Nozzle up, remove the Colored Cap, and quickly insert the Mating Fitting from the Disposable Fluid Path (Figure 6). Tighten firmly. 3. Ensure the Fluid Path is sealed with a Luer Fitting and Cap before transporting or loading the Cartridge into the Reservoir Retainer. NOTE: Low-viscosity fluids may require Teflon wrap on threads. Figure 5. Cartridge with Cap Installed Figure 6. Cartridge with Fluid Path Installed Nozzle Remove Cap Fluid Path Mating Fitting

Tridak Model 1050 Syringe Filling System User Guide 11 Loading the System Fill Material Reservoir 1. Remove the Reservoir Retainer Cover by removing the Star Nuts and Cover. Ensure the Retainer is free and clear of any previously placed cartridges or packaging. 2. Insert the Cartridge/Fluid Path Assembly into the Reservoir Retainer. 3. Guide the Fluid Path downward, passing through the bottom of the Reservoir. 4. Press the Cartridge firmly into place until seated. 5. Replace the Reservoir Retainer Cover and tighten evenly and securely with Star Nuts until the Cover forms a solid seal around the Cartridge. If you experience any trouble, please contact Dymax Customer Service. Figure 7. Material Reservoir Exploded Diagram Star Nut Star Nut Cover O-Ring Cartridge Cartridge Retainer Cartridge Mating Fitting Fluid Path

12 Tridak Model 1050 Syringe Filling System User Guide Install the Fluid Path 1. Remove the four 8-32 x 0.75" Screws (Figure 9) that hold the Tube Support and the Valve Body together. 2. Evenly loosen the two Luer Block Clamp Screws (Figure 8) enough to slip the Luer Tip Cap through the opening. Position the Fluid Path in the Luer Block Clamp so that the left edge of the Luer Block Clamp just catches the white Luer Tip. 3. Evenly tighten the two Luer Block Clamp Screws. 4. Install the Fluid Path and the Tube Support to the Model 830 Valve (Figure 8). The Tube Support has two access holes for the over-pinch and suck-back adjusts at the top of the cover and must be installed in the correct orientation. Evenly tighten the two Tube Support Removal Screws. Figure 8. Luer Block Clamp Luer Block Clamp Luer Tip Luer Block Clamp Screws

Tridak Model 1050 Syringe Filling System User Guide 13 Figure 9. Fluid Path Installation 8-32 x 0.75" Screws (4) Washers (4) Tube Support Assembled Unit Fluid Path / Tubing Over-Pinch Adjust Suck-Back Adjust Valve Body NOTE: Follow the same assembly and replacement for the following filling configurations: T15225 TUBE ASSEMBLY, LUER FEMALE

14 Tridak Model 1050 Syringe Filling System User Guide Pressurizing the System NOTE: Before operating the machine at the beginning of each run, check that all tubes, covers, guards, and safety devices are properly installed for operation. The system is energized when a compressed air supply is connected to the System Pressure Inlet. WARNING! Do not exceed 90 psi system pressure. The following steps must be completed in order to safely pressurize the system. If these steps are not followed correctly, it is possible to create a situation that could result in a material spill through the Luer Tip. 1. Ensure that the Fluid Path is correctly installed in the Luer Support and the Tube Support. 2. Check that the Luer Clamp and the Tube Support are tightened down fully. 3. Ensure the Luer Tip Cap is installed and tightened onto the Luer Tip. 4. Disconnect the Material Reservoir Pressure Supply from the Material Reservoir Air Inlet. 5. Connect a Compressed Air Supply (max 90 psi) to the System Pressure Inlet. 6. Set the Air Regulator to 0 psi. 7. Connect the Material Reservoir Pressure Supply to the Material Reservoir Air Inlet. 8. Set the Air Regulator to 10 psi starting pressure. 9. Check for any material leaks occurring at the Luer Tip or at the Material Cartridge and depressurize the system if any leaks are present. Depressurizing the System 1. Ensure the Luer Tip Cap is installed and tightened onto the Luer Tip. 2. Set the Air Regulator to 0 psi. 3. Disconnect the Material Reservoir Pressure Supply from the Material Reservoir Air Inlet. 4. Disconnect the Compressed Air Supply from the System Pressure Inlet. Set the Fill Amount for the Syringe Size For the required syringe size, use the scale to set the fill volume by adjusting the syringe fill stop to the desired location. 1. Disconnect the Compressed Air Supply from the System Pressure Inlet. 2. By hand, set the Syringe Plunger to the desired fill/ml volume. 3. Twist or slide the Syringe and extended Plunger on to the Nozzle/Needle/Luer Lock Tip of the Fluid Path. 4. Loosen the Syringe Fill Adjustment Lock by loosening the bottom two Allen Cap Screws (Figure 10). 5. Ensure the Syringe Fill Stop is at rest, and not extended.

Tridak Model 1050 Syringe Filling System User Guide 15 6. Move the Syringe Fill Stop to the position where it immediately touches the extended Syringe Plunger. 7. From this position, gently slide the Syringe Fill Stop 5 scale lines away from the Syringe Plunger. The Syringe Fill Stop will retract to this position when each syringe reaches the desired fill volume. 8. Re-tighten the Syringe Fill Stop using Allen Cap Screws. Figure 10. Model 1050 with Syringe Inserted Syringe Piston Syringe Plunger Syringe Fill Stop Luer Tip Syringe Allen Cap Screws Priming the System During initial setup and when changing material cartridge reservoirs, air must be purged from the disposable fluid path/fill tube to prevent accidental spills and introducing bubbles into syringes. Prime the system by running material through the fluid path until a constant, solid flow of material is achieved. Depending on material, reducing the pressure by 5-15 psi will make it easier to see the air being purged. Prepare the Syringes Before filling each syringe, ensure the syringe plunger is fully inserted to the tip of the syringe to remove most of the air from the empty syringe. Fill the Syringe 1. Remove the Cap from the Luer Tip. 2. Load the required Syringe size by threading it onto the Luer Tip (Figure 10). 3. Make sure all hands and fingers are clear of the machine. Press and hold the Foot Switch to activate the filling cycle. 4. Release the Foot Switch when the Syringe Plunger touches the Syringe Fill Stop. 5. Remove the Syringe from the Luer Tip. 6. Cap the Syringe Tip and the Syringe End as needed. 7. Repeat above steps 2 through 6 for each additional syringe needed.

16 Tridak Model 1050 Syringe Filling System User Guide Model 830 Valve Adjustments The 830 valve highlights a suck-back feature to prevent oozing and dripping between syringes. Depending on the type of fluids used, the suck-back feature will require adjustment. Batch-to-batch adjustment is recommended. If material drips, suck-back should be increased. If there are air bubbles in the syringe, decrease the amount of suck-back. Adjusting Suck-Back Position (Front) The Adjustment Screw is located on the top face of the valve. To increase suck-back, loosen the adjustment screw counter-clockwise. To decrease suck-back, tighten the adjustment screw clockwise. (Figure 11) Figure 11. Suck-Back Adjustment Screw Increase Suck-Back (Counter-Clockwise) Decrease Suck-Back (Clockwise) Cleaning and Maintenance System Cleaning Switching to a Different Material The disposable fluid path in the Model 830 valve allows for quick and easy material changeover. To switch your system over from dispensing one material to dispensing a new material, simply replace the fluid path tube in the dispensing valve. You will also need to replace the material reservoir on the system. The new material can be placed in a new material reservoir or the existing reservoir can be cleaned and the material replaced.

Tridak Model 1050 Syringe Filling System User Guide 17 Spare Parts and Accessories Replacement Parts/Accessories Part Number Item Air Lines & Regulators T16789 T18297 Air Supply Line Material Regulator Replacement Kit Reservoir Cartridge Kits T18306 T18307 20 oz Cartridge Assembly, HDPE 32 oz Cartridge Assembly, HDPE Luer Block Parts T18294 V-Block Top with Mounting Thumb Screws Model 830 Parts T18196 T18304 Model 830 Valve Spare Hardware Kit Includes: Valve Mounting Screw, Suck Back Adjust Screw, Screws for the Tube Support Tube Assemblies T15225 T18305 Tube Assembly, Luer Female Tube Assembly, No Tip (For Use with Custom Tooling) Misc. T18218 T16603 T18296 Bleed Wire with Pull Ring Pneumatic Foot Switch Stopper Assembly Replacement Kit

18 Tridak Model 1050 Syringe Filling System User Guide Specifications System Specifications Materials of Construction Wetted Parts Dispensing valve = No wetted parts. Fluid tubing = light blocking, black, polyethylene Fluid tubing fittings = acetal Fluid cartridge reservoirs = HPDPE Fluid cartridge reservoir piston = HDPE Operating Specifications Recommended compressed air supply pressure to air filter/regulator = 60 psi min (4.1 bar) Maximum pressure setting at air filter/regulator = 100 psi (6.9 bar) Compatible material viscosity range: 1 60,000 cp Reservoir Retainer/Tank Sizes Cartridge retainers hold 20 and 32-oz (550 and 900-mL) reservoirs 1 gallon (3.8 L) jug and 5 gallon (15L) pail drop in reservoir options available: inquire with Tridak Customer Service Air Regulator Pressure Gauges Pressure gauge installed from factory = 0 to 100 psi (0 to 6.9 bar) Dimensions Dimensions (L x W x H) 23.6 in x 12 in x 25 in (60 cm x 30.48 cm x 63.50 cm)

Tridak Model 1050 Syringe Filling System User Guide 19 Figure 12. Model 1050 Syringe Loader Dimensions

2015-2016 Dymax Corporation. All rights reserved. All trademarks in this guide, except where noted, are the property of, or used under license by Dymax Corporation, U.S.A. Please note that most filling and repackaging system applications are unique. Dymax does not warrant the fitness of the product for the intended application. Any warranty applicable to the product, its application and use is strictly limited to that contained in Dymax s standard Conditions of Sale. Dymax recommends that any intended application be evaluated and tested by the user to insure that desired performance criteria are satisfied. Dymax is willing to assist users in their performance testing and evaluation. Data sheets are available for pressure pots upon request. MAN074 2/17/2015 Dymax Corporation +1.860.482.1010 info@dymax.com www.dymax.com Dymax Europe GmbH +49 611.962.7900 info_de@dymax.com www.dymax.de Dymax Engineering Adhesives Ireland Ltd. +353 21.237.3016 info_ie@dymax.com www.dymax.ie Dymax Oligomers & Coatings +1.860.626.7006 info_oc@dymax.com www.dymax-oc.com Dymax UV Adhesives & Equipment (Shanghai) Co. Ltd. +86.21.37285759 dymaxasia@dymax.com www.dymax.com.cn Dymax UV Adhesives & Equipment (Shenzhen) Co. Ltd. +86.755.83485759 dymaxasia@dymax.com www.dymax.com.cn Dymax Asia (H.K.) Limited +852.2460.7038 dymaxasia@dymax.com www.dymax.com.cn Dymax Asia Pacific Pte. Ltd. +65.6752.2887 info_ap@dymax.com www.dymax-ap.com Dymax Korea LLC +82.2.784.3434 info_kr@dymax.com www.dymax.com/kr