Extraordinary results begin with superior labware

Similar documents
Thermo Scientific Chromatography Well Plates

Thermo Scientific Chromatography Well Plates

SuperClear 15mL and 50mL Centrifuge Tubes

Types of centrifugal separations

96-Well Multi-Tier Micro Plate System (Patented)

UP-F Delrin TM Winged Nut. UP-F PEEK TM Nut. with F-142 PEEK TM Ferrule

BIOCLOSURE SYSTEM ASSEMBLIES

Compressor Seal Replacement and Upgrades SERVICES

SIMPLAIR PIPING TOOL. JXT Company

Form No. P Meter, PD Series H8-S3 Flat Plate Cover Parts List

User Guide. Pall Laboratory Manifold. For laboratory use. Not for use in a manner other than indicated. Introduction. Regulatory References

DIAGNOSTIC CARDIOLOGY

Replaces Lesco 300 & 500 Parts Cutting Unit

SCF Enviro-Friendly. Back-up Ring. Endcap. #7141 (for both) O-Ring. Back-up ring and O-ring fit onto end cap.

MUELLER. A Wall Type. Indicator Post. Reliable Connections. General Information 2. Technical Data/ Dimensions 3. Installation 4-5.

MyControl Bathing System Signature Series

KAYDON RING & SEAL, INC.

Safety Wear. Peace of Mind

Edward Valves Equiwedge Forged Gate Valve

Filtration FILTRATION PRODUCT TIPS

INSTALLATION INSTRUCTIONS

Albany Connecticut Vermont Westchester

Meter, PD Series, E3 A1, S1 and E4 S1 Prior to 2005 Parts List

Running HPLC Methods on an ACQUITY UPLC System

!!!! SERVICE MANUAL PRESSURE POT 2 GALLON. Service Manual: LT Washington St 931 Progress Ave., #7

High Pressure Equipment Pressure Vessels and Reactors Index

Neotecha Tank Sampling Sapro

Meter, PD Model T-11 and T-11NF Parts List

Meter, PD Series, E3 S1 and E4 S to Present Parts List

Meter, PD Series, E3 S6, S7 All Parts List

Transferpette. Single and Multichannel Pipettes

Pressure Dump Valve Service Kit for Series 3000 Units

Media-Isolated Mag Plus Probe Low Pressure-ISO Kit

SEries 29 Hydrant valves installation, operation & maintenance manual

MUELLER A A Non-Adjustable. Vertical Indicator Posts. Reliable Connections. General Information 2. Technical Data 3.

APPENDIX A MAIN ASSEMBLIES

Agilent 1290 Infinity Pump Head Maintenance

Contents. Stainless Steel Side Block. 1.1 Separating the Side Block. Stainless Steel Side Block Reassembly of. Assembly from the Helmet Shell

Installation Instructions

CONNECTION > Super-rapid fittings Series 6000 GENERAL DATA. Fitting with connecting tube. Sprint

Neotecha SAPRO - Tank Valve Type ST for aseptic sampling with bottles Installation, Operation and Maintenance Instruction

DISASSEMBLY AND ASSEMBLY INSTRUCTIONS FOR LIQUID RING COMPRESSORS

// ADapters GUIDelines

INSTALLATION & MAINTENANCE INSTRUCTION

Assembly Instructions

Installation Instructions

INSERT FITTINGS INSERT FITTINGS

Pressure Dump Valve Service Kit for Series 2300 Units

MUELLER. A A Adjustable. Vertical Indicator Posts. Reliable Connections. General Information 2. Technical Data 3.

Trilogy Theory of Operation

TECHNICAL HANDBOOK nvent CADDY Speed Link Manual. SLS Locking Device

Bike holder with three-point-support for mounting stand

Installation Guide. buoy.ai

Operating Procedures for GripTight 15.5 SDR & IPS Test Plugs

Y:\Machine Manuals & Spare Parts Lists\PARTS BREAKDOWN\Commercial CW Gas\HD850WS Page 1

RST INSTRUMENTS LTD.

INSTALLATION AND OPERATING INSTRUCTIONS

Welker Sampler. Model GSS-1. Installation, Operation, and Maintenance Manual

PVC FASTTAP SADDLES for IPS Mains. Main Size OUTLET 1 FPT 3/4 CTS (7/8 OD) COMPRESSION 1 CTS (1 1/8 OD) COMPRESSION 3/4 IPS COMPRESSION

K Page 1 of 48 Air Intake - Pg. 17

Chapter 9 Accessories

Neotecha SAPRO - Aseptic sampling valve SV Installation, operation and maintenance instructions

ACID FAST BACTERIA MICROBIOLOGY STAINER / CYTOCENTRIFUGE WESCOR, INC

Chapter 9 Accessories for the Kirby Morgan BandMasks

NEW Edge Series Products: OUTFITS and REGULATORS

D. ACCESSORIES ADAPTER KITS IMPELLER & SEAL INSTALLATION TOOLS CARRYING HANDLES & LIFT CORDS GALVANIC PROTECTION KITS MUSHROOM STRAINER

Neotecha Tank Sampling Sapro

Articulating Legs with Intraosseous Infusion Simulator LF03840U Instruction Manual

Need the part number for an impeller, seal, gasket, or motor? It s all here.

Smith Meter PD Meter Meter, PD Series, F4 S6, S7. Parts List Bulletin PO01012 Issue/Rev 0.0 (7/13)

Presented by ARAMSCO

WELLS JOHNSON HIGH VOLUME CANISTERS

SDV Single Diaphragm Valve On/Off Manual/Pneumatic Flare, S-300, FNPT, Tube 58 psi 1/4-1/ psi 3/4-1

Installation Procedure for your Disco Double Kit, by Airgun Lab, LLC.

AIR STAPLER. MODEL: CSG3KC Part No OPERATING & MAINTENANCE INSTRUCTIONS

United States Patent 19 Carver

Installation, Operation & Maintenance Manual

Flexible Metal Hose Products

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly.

Gas Lines. Technical Manual. Sumitomo (SHI) Cryogenics of America, Inc Vultee Street Allentown, PA U.S.A.

Keofitt Aseptic Sampling Bag (Pat. pend.) Item no , & User Manual

KEOFITT ASEPTIC SAMPLING BAG (PAT. PEND.) Item no , & User Manual

PNEUMATIC PRESSURE CONTROLLERS

Underground irrigation

Installation, Operation and Maintenance Manual for Back Pressure Regulator

PILOT OPERATED RELIEF VALVE SAFETY PRODUCTS THAT PROTECT EQUIPMENT, LIVES & THE ENVIRONMENT

Standard Specifications

High Pressure Equipment Medium Pressure Valves, Fittings and Tubing

Push-in fittings NPQH

Underwater Housing for Canon EOS M

GASKET CUTTER SYSTEMS

Transferpette. Lightweight precise rugged reliable!

Satisfaction. For you and your patients.

Threaded Closures Installation, Operation & Maintenance

Compatible with a Wide Range of Gases or Liquids for Laboratory or Plant Applications

4400 TwinHybrid Gas Seal

Tank Blanketing Pressure Regulators RHPS Series

Pneumatic Wet Sander. (4,500 rpm) Operation Instruction

Transferpette. Lightweight precise rugged reliable!

MVS Volume Verification Using Any Microtiter Plate or Small Volume Container, Such as a Tube or Vial

Transcription:

Extraordinary results begin with superior labware Ultracentrifugation Labware Floor and Tabletop

INVESTING IN THE SAFETY OF YOUR LAB With total-system design in mind from the start, Beckman Coulter designs our ultracentrifuge Labware to complement our Optima Series ultracentrifuges, optimizing performance, ease of use, and safety. Beckman designs the rotors in a way that the tube/bottle is supported correctly to minimize high stress areas that may cause premature failure Compare theoretical models vs actual results During the rotor design phase, sophisticated simulation software allows engineers to remove problem areas Then physical rotors, loaded with consumables, go through MCA (Maximum Credible Accident) tests to verify that the simulation results were correct and everything is contained The results are part of the certification process for the CSA and CE marks. Therefore, using Beckman Coulter consumables with Beckman Coulter rotors is necessary. Consumables to match your workflow SEALING OptiSeal Tubes Employ patented technology to provide a fast, reliable seal every time. Seal with a finger-touch and without tools, heat, or closure verification. Wide necks offer effortless filling and fraction collection Quick-Seal tubes Provide secondary BioSafe* containment. Seal with a simple, hand-held sealing tool without plugs or orings. Available in both round and konical bottom. OPEN TOP Open Top Tubes Allow centrifuging in fixed-angle and swinging-bucket rotors. Available in multiple materials as well as thinwall and thickwall options. BOTTLES Bottle Assemblies With both two and three-piece caps, bottles are reusable and ensure containment while centrifuging large volume samples SPECIALTY Stainless steel tubes Can be used with toluene and other organic solvents, crucial for many nanoparticle applications Cellulose Propionate Are transparent and designed for one-time use. These tubes have good tolerance to all gradient media including alkalines. 1.5mL Snap-Caps *Biosafe is a term intended to describe enhanced biocontainment features of our products. Brilliance at Every Turn

ULTRA ROTOR AND TUBE TYPE GUIDE Floor Prep Ultracentrifuge Table-Top Ultracentrifuge Fixed Angle Swinging Bucket NVT Vertical Fixed Angle Swing Bucket Type Type 100 Ti Sealing Open Top Bottles Specialty OptiSeal Quick-Seal Thinwall Thickwall PP UC PP konical UC PP konical PP PC PET PP PC SS Type 90 Ti Type 70.1 Ti Type 70 Ti Type 50.4 Ti Type 50.2 Ti Type 45 Ti Cellulose Propionate Type 42.2 Ti Type 25 Type 19 SW 60 Ti SW 55 Ti SW 41 Ti SW 40 Ti SW 32.1 Ti SW 32 Ti SW 28.1 Ti SW 28 Ti NVT 100 NVT 90 NVT 65.2 NVT 65 VTi 90 VTi 65.2 VTi 65.1 VTi 50 TLA-120.2 TLA-120.1 1.5mL PP Snap-Caps TLA-110 TLA-100.3 TLA-100 TLA-55 MLA-150 MLA-130 MLA-80 MLA-55 MLA-50 TLS-55 MLS-50 NVT TLN-120 TLN-100 MLN-80 Note: Accessories, adapters, spacers, and/or caps may be required for some of the rotor and tube combinations For a complete listing of rotor and tube offerings, please consult our online Ultracentrifuge catalog at www.beckman.com Abbreviations: PP Polypropylene, UC Ultra-Clear, PC Polycarbonate, SS Stainless Steel, PET Polyethylene Material Properties Ultra-Clear Polycarbonate Polypropylene Polyethylene Cellulose Propionate Stainless Steel Visibility Clear Clear Translucent Translucent Clear Opaque Sterilization Methods Chemical Autoclavable Autoclavable Chemical Chemical Autoclavable Chemical Resistance Poor Poor Great Good Poor Great Puncturable Reusable (thinwall) (thickwall) (thinwall)

SEALING TUBES Beckman Coulter offers 2 different types of sealing tubes that are compatible with Ultracentrifuge rotors Sealable tubes allow for the 1st level of biocontainment for tube transfers to rotors OptiSeal Tubes Material Offering: Thinwall PP Volume Range: 3.3mL 36.2mL Compatible with 20 Ultra Rotors Can be sliced or punctured Wider tube neck allows for easier buffer and sample exchange Uses a push-in Noryl plug with o-ring to seal tubes Ability to be unplugged for sample recovery Tube rack provides a convenient means of holding tubes during loading and unloading, which also keeps fingers clear during syringe extraction Requires spacer above tube during centrifugation Tube plug is forced into stem by spacer 1 FILL Centrifugal force Hydrostatic pressure Tube stem elongates due to hydrostatic pressure 4 SPIN 2 PLUG 3 LOAD Most Popular OptiSeal Tubes Volume (ml) PN Material Size (mm) Rotors Supported 32.4 361625 Polypropylene 25 x 77 Type 70 Ti, Type 50.2 Ti, SW 32 Ti, SW 28, MLA-50 8.9 361623 Polypropylene 16 x 60 Type 90 Ti, Type 70.1 Ti, MLA-55 4.9 362185 Polypropylene 13 x 51 VTi 90, VTi 65.2, NVT 90, NVT 65.2 4.7 362621 Polypropylene 13 x 48 Type 50.4 Ti, TLA-110 Brilliance at Every Turn

Quick-Seal Tubes Material Offerings: Thinwall PP and Ultra-Clear Volume Range: 1mL 100mL Styles: Round Bottom and konical Bottom Compatible with 36 Ultra Rotors Can be sliced or punctured Handheld heat sealer and accessories to seal the tubes Requires spacers above tube during centrifugation g-max System allow flexibility of volumes within the same ultracentrifuge rotors while maximizing efficiency g-max Floating Spacer Spacer R max Shortened; Max G-force Reduced R max Retalned; Max G-force Reduced Pathlength with full-size tube Conventional Adapter Floating Spacer of g-max System Beckman Coulter Ultra-Clear Material Same optical properties as Polycarbonate, but allows for simplified sample recovery by syringe extraction Advantages of g-max spacers No reduction in Rotor g-force Reduced run time (shorter path length) Handheld sealing tool Tube removal tool Most Popular Quick-Seal Tubes Volume (ml) PN Material Size (mm) Rotors Supported 100.0 345776 Polypropylene 38 x 102 Type 45 Ti 100.0 345778 Ultra-Clear 38 x 102 Type 45 Ti 39.0 342414 Polypropylene 25 x 89 Type 70 Ti, Type 50.2 Ti, VTi 50 39.0 344326 Ultra-Clear 25 x 89 Type 70 Ti, Type 50.2 Ti, VTi 50 13.5 342413 Polypropylene 16 x 76 Type 90 Ti, Type 70.1 Ti, NVT 65, VTi 65.1, MLA-55

OPEN TOP TUBES Thinwalled Open-Top Tubes Material Offerings: Ultra-Clear, Polypropylene, and Polyethylene Volume Range: 175uL 94mL Styles: round bottom and konical bottom Thinwall tubes designed for single-use Offer large opening for easy sample loading and recovery Cap sealing assemblies may be required for fixed angle rotors Set Screw Insert Hex Nut Washer Crown O-ring or Gasket Stem Tube Fixed angle rotor cap assembly konical bottom tubes concentrate small samples, like RNA, which are pelleted into the bottom of the tube for the most concentrated pellet and easier recovery Ultra-Clear Tubes In applications like viral vectors, customers need to visually see distinct bands and be able to easily syringe extract them through the side of tube Thinwall vs Thickwall Thickwalled Open-Top Tubes Material Offerings: Polycarbonate, Polypropylene, and cellulose Propionate Volume Range: 230 ul - 94 ml Thickwall tubes are able to be reused Offer large opening for easy sample loading and recovery Insert tube form bottom Tube-Cap Vise (305075) Most Popular Open-Top Thinwall Tubes Volume (ml) PN Material Size (mm) Rotors Supported 38.5 344058 Ultra-Clear 25 x 89 Type 70 Ti, Type 50.2 Ti, SW 32 Ti, SW 28 38.5 326823 Polypropylene 25 x 89 Type 70 Ti, Type 50.2 Ti, SW 32 Ti, SW 28 14.0 344060 Ultra-Clear 14 x 95 SW 40 Ti 14.0 331374 Polypropylene 14 x 95 SW 40 Ti 13.2 344059 Ultra-Clear 14 x 89 SW 41 Ti 13.2 331372 Polypropylene 15 x 89 SW 41 Ti 5.0 344057 Ultra-Clear 13 x 51 SW 55 Ti, MLS-50 Brilliance at Every Turn

BOTTLES AND SPECIALTY TUBES Bottles Material Offerings: Polypropylene and Polycarbonate Volume Range: 8.5mL 250mL 3 piece liquid-tight cap assemblies provides leak-proof closure Reusable and supports larger volumes Specialty Tubes Stainless Steel Volume: 38.5mL & 94mL Great chemical resistance Can be centrifuged at any fill level Excellent heat resistance 1.5mL Snap-Caps Low-volume (1.5mL) easy seal tubes Inert material (PP) Conical bottom allows for tight pellet Cellulose Propionate Small volume: 230uL Clear Tolerant to most gradient media, including alkalines Most Popular Bottles Volume (ml) PN Material Size (mm) Rotors Supported 250.0 344205 Polypropylene 60 x 120 Type 19 70.0 355622 Polycarbonate 38 x 102 Type 45 Ti 26.3 355618 Polycarbonate 25 x 89 Type 70 Ti, Type 50.2 Ti, 10.4 355603 Polycarbonate 16 x 76 Type 90 Ti, Type 70.1 Ti, MLA-55

SAMPLE RECOVERY TOOLS HOLLOW-CONE CAP ASSEMBLY Plug 331593 Lock-ring Collar 339194 Spring 878224 Thumbscrew Drain Tube 331598 Hollow-cone Cap Plug 331593 Bushing 331594 O-ring 807475 Upper Mount 343787 Gasket Swivel Fitting 313336 FLAT-CONE CAP ASSEMBLY Tube Support Shaft* O-ring 863590 Plug 885086 Guide Post 343781 Lower Mount Flat-bottomed Cap 339192 Tube Mounting Pad 343785 Thumbscrew 343795 Swivel Fitting 313336 Gasket 339191 Needle Assembly 343786 Teflon Tubing Seal, Cushion 331601 Ringstand Fraction Recovery System Allows for fraction recovery of multiple tube types. Different adapters allow for bottom or top fraction recovery, depending on the tube type. Tube Slicer Used to slice thinwall tubes for sample recovery. The blade of slicer acts as barrier to mixing of separated fractions. Beckman Coulter s legacy for centrifuge quality and innovation encompasses more than 60+ years. We apply our technology leadership not only to our instruments and rotors, but also the design and fabrication of centrifuge bottles, tubes, and adapters. Our pioneering ultracentrifuge products include more than 130 different types of labware, allowing us to provide the best solution for your sample as well as increased safety and ease of use For more information regarding consumables; visit http://info.beckmancoulter.com/centrifugeconsumables 2017 Beckman Coulter, Inc. All rights reserved. Beckman Coulter, the stylized logo, and the Beckman Coulter product and service marks used herein are trademarks or registered trademarks of Beckman Coulter, Inc. in the United States and other countries. For Beckman Coulter s worldwide office locations and phone numbers, please visit Contact Us at beckman.com CENT-2404SB02.17