GRUNDFOS DATA BOOKLET Complete pressure boosting systems 5/6 z
Contents Product data Performance range 3 Operating conditions Inlet pressure Type key Product range 5 Construction 5 Installation 5 Mechanical installation 6 Diaphragm tank 6 Curve conditions 6 Electrical connection 6 Control of CRE pumps Control options of CRE pumps 7 Central management system 7 Remote control 7 Control panel 7 Overview of functions 8 Electrical installation Additional protection 9 Wiring diagram, single-phase 9 Wiring diagram, three-phase 1.5-7.5 kw 9 Technical data, CRE 1-xx 1, CRE 3-xx 11, CRE 5-xx 1 ydro solo-e, CRE 1-xx 13, CRE 15-xx 1, CRE -xx 15, CRE 3-xx 16, CRE 5-xx 17 Accessories R1 18 Dry-running protection 18 Further product documentation WinCAPS 19 WebCAPS
Product data Performance range 1 5 z ISO 996 Annex A 9 8 7 6 5 CRE 1 CRE 3 CRE 5 CRE 1 3 CRE 15 CRE CRE 3 CRE 5 1 3 6 8 1 3 6 Q [m³/h] TM 7577 383 3
Product data Grundfos booster set with one pump is a combined unit consisting of one E-pump (CRE) fitted with isolating valve, non-return valve, discharge pipe, pressure transmitter, pressure gauge and diaphragm tank. Upon delivery the booster set is ready for operation. Fig. 1 PUMP PUMP PRESSURE TRANSMITTER Principal sketch of Operating conditions Liquid temperature: C to +7 C Ambient temperature: C to + C System pressure: The maximum system pressure is 1 bar. The total of inlet pressure and head must not exceed the maximum system pressure. Inlet pressure NON-RETURN VALVE VALVE PRESSURE GAUGE ISOLATING VALVE PRESSURE GAUGE ISOLATING VALVE Minimum inlet pressure: The minimum inlet pressure in metres head required to avoid cavitation in the pump is calculated as follows: = p b x 1. NPS f v s p b = Barometric pressure in bar. Barometric pressure can be set to 1, if required. NPS = Net Positive Suction ead in metres head. NPS can be read from the NPS curve at the maximum capacity at which the pump will run. f = Friction loss in suction pipe in metres head. v = Vapour pressure in metres head. s = Safety margin of min..5 metres head. TM 87 79 Maximum inlet pressure. CRE 1 1-7, 1-15, 1-19 1 [bar] CRE 3 3-7, 3-1 1 [bar] CRE 5 5-, 5-8, 5-1, 5-16 1 [bar] CRE 1 1-3, 1-, 1-6 1-9 CRE 15 15-, 15-3 15-5 CRE -3-5 CRE 3 Example of operating and inlet pressures The values for operating and inlet pressures must not be considered individually but must always be compared, see the following example: Example: The following pump type has been selected: CRE 1- A-A-A Max. operating pressure: 1 bar Max. inlet pressure: 8 bar Desired pressure boosting: bar This pump is allowed to start at an inlet pressure of 8 bar as the discharge pressure is only bar which results in an operating pressure of 8. + = 1 bar. Type key Single-phase: Three-phase: 8 [bar] 1 [bar] 8 [bar] 1 [bar] 8 [bar] 1 [bar] 3-3 [bar] CRE 5 5- [bar] Example CRE 5-8 1 x - V Type range Subgroup Pump type Supply voltage Example CRE 1-1 x - V Type range Subgroup Pump type Supply voltage
Product data Product range Pump type Pressure Product numbers Motor transmitter [bar] 1 x - V 3 x 38-8 V CRE 1-7.37-1 966788 - CRE 1-15.75-1 966786 - CRE 1-19 1.1-1 9667861 - CRE 3-7.55-1 966786 - CRE 3-1.75-1 9657865 - CRE 3-1 1.1-1 - 9668197 CRE 5-.55-1 9667867 - CRE 5-8 1.1-1 9667868 967953 CRE 5-1 1.5-1 - 9667871 CRE 5-16. -1-966787 CRE 1-3 1.1-1 96513873 - CRE 1-1.5-1 - 9651387 CRE 1-6. -1-96513875 CRE 1-9 3. -1-96513876 CRE 15-. -1-96513877 CRE 15-3 3. -1-96513878 CRE 15-5. -1-96513879 CRE -3. -1-9651388 CRE -5 5.5-1 - 96513881 CRE 3-3 5.5-1 - 9668199 CRE 5-5.5-1 - 96681 Construction Pos. Designation Qty. 1 CRE pump 1 Diaphragm tank 1 3 Pressure gauge 1 Isolating valve for diaphragm tank and pressure gauge 1 5 Isolating valve 1 6 Discharge pipe (stainless steel) 1 7 Pressure transmitter 1 8 Non-return valve 1 9 On/off-switch 1 1 Nameplate 1 On the discharge side of the pump are fitted a nonreturn valve, a stainless steel discharge pipe (EN/DIN 1.1 or EN/DIN 1.571) and an isolating valve. On the discharge pipe are fitted a pressure transmitter and an isolating valve for the pressure gauge and the diaphragm tank. The pump is fitted with an on/off-switch for the supply voltage. 1 9 Fig. Installation 8 Construction of A booster set must be installed in a well ventilated room to ensure sufficient cooling for the pump. is not suitable for outdoor installation. The booster set should be placed with sufficient clearance around it. Enclosure class: IP 55 Insulation class: F. 1 7 6 3 5 TM 756 383 5
Product data Mechanical installation The pipes connected to the booster set must be of adequate size. To avoid resonance, expansion joints should be fitted both in the discharge and suction pipes. The pipes are to be connected to the discharge pipe and the pump suction port. The booster set should be tightened up prior to start-up. It is always advisable to fit pipe hangers both on the suction and discharge side. The system should be positioned on an even and solid surface, e.g. a concrete floor or foundation. If the booster set is not fitted with vibration dampers, it must be bolted to the floor or foundation. Curve conditions The following curves are subject to the following guidelines: Performance measurement is made at a water temperature of + C. Test liquid: Pure water. The curves describe the pump mean values. The curves should not be used as guarantee curves. Curve tolerance: ISO 996, Annex A. The conversion between head (m) and pressure p (kpa) has been made for water with a density of ρ = 1 kg/m 3. The curves apply to a kinematic viscosity of 1 mm /s (1 cst). Electrical connection Fig. 3 Mechanical installation 1. Expansion joints. Pipe hangers Expansion joints and pipe hangers shown are not included in a standard booster set. Diaphragm tank 1 1 The diaphragm tank is pre-charged to correct pressure. If the setpoint is altered, a new pre-charge pressure should be calculated to obtain optimal duty: Calculation of pre-charge pressure: Pre-charge pressure =.7 x setpoint The diaphragm tank s pre-charge pressure must be measured in a pressureless system. It is recommended to refil the tank with nitrogen. TM1 7 797 The electrical connection and protection should be carried out in accordance with local regulations. The pump must be connected to an external mains switch. The E-pump must always be correctly earthed. Note: The. - 7.5 kw motors must be connected to especially reliable/sturdy earth connections due to an earth leakage current above 3.5 ma. The pump requires no external motor protection. The motor incorporates thermal protection against slow overloading and blocking (IEC 3-11: TP 11). When the pump is switched on via the mains, the pump will start after approx. 5 secs. Note: The number of starts and stops via the mains voltage must not exceed times per hour. The pump mains connection must be made as shown in the diagrams below. 6
Control of CRE pumps Control options of CRE pumps Communication with CRE pumps is possible by means of a central management system, remote control (Grundfos R1) or a control panel. The purpose of controlling an E-pump is to monitor and control the pressure, temperature, flow and liquid level of the system. Central management system Communication with the CRE pump is possible even though the operator is not present near the CRE pump. Communication is enabled by having connected the CRE pump to a central management system allowing the operator to monitor and change control modes and setpoint settings of the CRE pump. Remote control The R1 remote control produced by Grundfos is available as an accessory. The operator communicates with the CRE pump by pointing the IR-signal transmitter at the control panel of the E-pump terminal box. Fig. 5 R1 remote control On the R1 display it is possible to monitor and change control modes and settings of the CRE pump. TM 98 8 Control panel The control panel of the CRE pump terminal box makes it possible to change the setpoint settings manually. Light fields LON-bus connection Buttons G1-LON Interface Indicator lights TM 76 Fig. 6 Control panel on CRE pump GENIbus connection CRE pump TM659 113 Fig. Structure of a central management system 7
Control of CRE pumps Overview of functions E-pumps/functions TM 76 TM 98 8 Setting via control panel: Setpoint Start/stop Max. curve Min. curve Reading via control panel: Setpoint Operating indication Fault indication Setting via R1: Setpoint Start/stop Max. curve Min. curve Controlled/uncontrolled PI-controller Signal relay Operating range Stop function Reading via R1: Setpoint Operating indication Pump status 8
Electrical installation Additional protection If the pump is connected to an electric installation where an earth leakage circuit breaker (ELCB) is used as an additional protection the earth leakage circuit breakers must be marked with the following symbols. Single-phase: The earth leakage circuit breakers must trip out when earth fault currents with DC content (pulsating DC) occur. Three-phase: The earth leakage circuit breakers must trip out when earth fault currents with DC content (pulsating DC) and smooth DC earth fault currents occur. Wiring diagram, single-phase 1 x - V, +/ 1% External switch N N L ELCB Max. 1 A PE L PE TM 79 11 Wiring diagram, three-phase 1.5-7.5 kw 3 x 38-8 V, +/ 1% External switch L1 Max. 1 A L1 L ELCB L L3 L3 PE TM 97 696 9
Technical data with CRE 1 p [kpa] 1 1 8 13 1 11 1 9 8 CRE 1-19 CRE 1-15 CRE 1 ISO 996 Annex A 7 6 6 5 3 CRE 1-7 NPS 3 6 TM1 58 393 1 NPS 1...8 1. 1.6. Q [m³/h]....6 Q [l/s] P 1. -19.8-15.6......8 1. 1.6. Q [m³/h] -7 TM 317 383, CRE 1-xx Electrical data, dimensions and weights Pump type Full load Supply voltage Diaphragm Connection Weights [kg] Motor Packing current tank [mm] 1/1 [A] 1 x - V, PE 3 x 38-8 V, PE [litres] inlet outlet Net Gross [m 3 ] CRE 1-7.37 3.-.5-8 Rp 1¼ Rp 1¼ 537 39...6 CRE 1-15.75 5.1-.7-8 Rp 1¼ Rp 1¼ 77.7 7.7.6 CRE 1-19 1.1 7.-6.8-8 Rp 1¼ Rp 1¼ 779 7. 5..6 1
Technical data with CRE 3 p [kpa] 6 5 3 1 7 65 CRE 3-1 CRE 3 6 ISO 996 Annex A 55 5 5 CRE 3-7 35 3 5 15 1 5 NPS..8 1.6. 3.. Q [m³/h] NPS 3 1 6 TM1 57 393...8 1. Q [l/s] P.8.6.. -1...8 1.6. 3.. Q [m³/h] -7 TM 318 383, CRE 3-xx Electrical data, dimensions and weights Pump type Full load Supply voltage Diaphragm Connection Weights [kg] Motor Packing current tank [mm] 1/1 [A] 1 x - V, PE 3 x 38-8 V, PE [litres] inlet outlet Net Gross [m 3 ] CRE 3-7.55.3-3.6-8 Rp 1¼ Rp 1¼ 519 39.6.9.6 CRE 3-1.75 5.1-.7-8 Rp 1¼ Rp 1¼ 617.9 5.9.6 CRE 3-1 1.1.6-.3-8 Rp 1¼ Rp 1¼ 617.9 5.9.6 11
Technical data with CRE 5 p [kpa] 1 1 11 1 CRE 5-16 CRE 5 ISO 996 Annex A 8 9 8 7 CRE 5-1 6 6 5 3 CRE 5-8 CRE 5- NPS 3 6 TM1 57 393 1 NPS 1 1 3 5 6 7Q [m³/h]..5 1. 1.5. Q [l/s] P.5-16. 1.5-1 1. -8.5 -. 1 3 5 6 7Q [m³/h] TM 319 383, CRE 5-xx Electrical data, dimensions and weights Pump type Full load Supply voltage Diaphragm Connection Weights [kg] Motor Packing current tank [mm] 1/1 [A] 1 x - V, PE 3 x 38-8 V, PE [litres] inlet outlet Net Gross [m 3 ] CRE 5-.55.3-3.6-18 Rp 1¼ Rp 1¼ 51.8 3.8.6 CRE 5-8 1.1 7.-6.8-18 Rp 1¼ Rp 1¼ 653 7. 5..6 CRE 5-8 1.1.6-.3-18 Rp 1¼ Rp 1¼ 653 7. 5..6 CRE 5-1 1.5 3.3-.7-18 Rp 1¼ Rp 1¼ 773 56.6 59.6.6 CRE 5-16..6-3.8-18 Rp 1¼ Rp 1¼ 773 61.8 6.8.6 1
Technical data with CRE 1 p [kpa] 1 8 1 11 1 9 8 CRE 1-9 CRE 1 ISO 996 Annex A 6 7 6 5 3 CRE 1-6 CRE 1- CRE 1-3 NPS 3 65 5 TM 7563 383 1 NPS 1 6 8 1 Q [m³/h]..5 1. 1.5..5 3. Q [l/s] P 3. -9.5. 1.5 1..5. 6 8 1 Q [m³/h] -6 - -3 TM 753 383ydro solo-e, CRE 1-xx Electrical data, dimensions and weights Pump type Full load Supply voltage Diaphragm Connection Weights [kg] Motor Packing current tank [mm] 1/1 [A] 1 x - V, PE 3 x 38-8 V, PE [litres] inlet outlet Net Gross [m 3 ] CRE 1-3 1.1 7.-6.8-33 Rp 1½ Rp 1½ 68 6. 65..6 CRE 1-1.5 3.3-.7-33 Rp 1½ Rp 1½ 7 71. 7..6 CRE 1-6..6-3.8-33 Rp 1½ Rp 1½ 8 8. 83..6 CRE 1-9 3. 6.-5. - 33 Rp 1½ Rp 1½ 913 87. 9..6 13
Technical data with CRE 15 p [kpa] 8 8 7 CRE 15-5 CRE 15 ISO 996 Annex A 6 6 5 3 CRE 15-3 CRE 15- NPS 6 7 5 TM 756 383 1 NPS 8 1 16 Q [m³/h] 6 Q [l/s] P 3 1 8 1 16 Q [m³/h] -5-3 - TM 7535 383, CRE 15-xx Electrical data, dimensions and weights Pump type Motor Full load current 1/1 [A] Supply voltage 3 x 38-8 V, PE Diaphragm tank [litres] Suction side Connection Discharge side [mm] Weights [kg] CRE 15-..6-3.8 33 DN 5 Rp 736 91. 9..6 CRE 15-3 3. 6.-5. 33 DN 5 Rp 8 96. 99..6 CRE 15-5. 8.1-6.6 33 DN 5 Rp 97 115. 188..6 Net Gross Packing [m 3 ] 1
Technical data with CRE p [kpa] 8 9 8 7 CRE -5 CRE ISO 996 Annex A 6 6 5 3 CRE -3 NPS 6 7 5 TM 756 383 1 NPS 8 1 16 Q [m³/h] 6 Q [l/s] P 5-5 3 1 8 1 16 Q [m³/h] -3 TM 7536 383, CRE -xx Electrical data, dimensions and weights Pump type Motor Full load current 1/1 [A] Supply voltage 3 x 38-8 V, PE Diaphragm tank [litres] Suction side Connection Discharge side [mm] Weights [kg] CRE -3. 8.1-6.6 33 DN 5 Rp 837 11. 115..6 CRE -5 5.5 11.-8.8 33 DN 5 Rp 978 136. 133..6 Net Gross Packing [m 3 ] 15
Technical data with CRE 3 p [kpa] 6 5 3 1 7 65 CRE 3 6 CRE 3-3 ISO 996 Annex A 55 5 5 35 3 5 15 1 NPS 5 5 1 15 5 3 Q [m³/h] NPS 7 6 5 3 1 669 31 TM 7565 383 6 8 1 Q [l/s] P 6 5-3 3 1 5 1 15 5 3 Q [m³/h] TM 3 383, CRE 3-xx Electrical data, dimensions and weights Pump type Motor Full load current 1/1 [A] Supply voltage 3 x 38-8 V, PE Diaphragm tank [litres] Suction side Connection Discharge side [mm] Weights [kg] CRE 3-3 5.5 11.-8.8 33 DN 65 DN 65 136 138. 13..6 Net Gross Packing [m 3 ] 16
Technical data with CRE 5 p [kpa] 5 6 55 5 CRE 5- CRE 5 ISO 996 Annex A 5 3 35 3 5 15 NPS 5 3 71 31 TM 7566 383 1 1 5 NPS 1 1 3 5 Q [m³/h] 5 1 15 Q [l/s] P 8 6 1 3 5 Q [m³/h] - TM 31 383, CRE 5-xx Electrical data, dimensions and weights Pump type Motor Max. I N [A] Supply voltage 3 x 38-8 V, PE Diaphragm tank [litres] Suction side Connection Discharge side [mm] Weights [kg] CRE 5-5.5 11.-8.8 33 DN 8 DN 8 19 16. 19..6 Net Gross Packing [m 3 ] 17
Accessories R1 R1 is used for wireless communication. The communication takes place by means of infrared light. Product Product number R1 65333 Dry-running protection Type Pressure [bar] To protect the booster set against dry running, dryrunning protection is obligatory. The dry-running protection unit is to be mounted on the site. Automatic reset after water shortage Product number.11-96153. - 9615.5-8 96155 Pressure switch PS CRE pump Level switch CRE pump CRE pump CRE pump PS 1 Digital input LS 1 Digital input Start/stop 3 GND (frame) TM 56 3 Start/stop 3 GND (frame) TM 589 3 Manual reset after water shortage Pressure switch PS CRE pump Level switch CRE pump CRE pump CRE pump PS 1 Digital input LS 1 Digital input 3 GND (frame) TM 561 3 3 GND (frame) TM 59 3 18
Further product documentation In addition to the printed data booklet, Grundfos offers the following sources of product documentation. WinCAPS WebCAPS. WinCAPS WinCAPS is a Windows-based Computer-Aided Product Selection program containing information on more than 9, Grundfos products. Available on CD-ROM in more than 15 languages, WinCAPS offers detailed technical information selection of the optimum pump solution dimensional drawings of each pump detailed service documentation installation and operating instructions wiring diagrams of each pump. Fig. 7 WinCAPS CD-ROM cd-wincaps Click on Catalogue and select a product from the extensive product catalogue. Click on Sizing and select the most suitable pump for your application. WinCAPS Fig. 8 WinCAPS 19
Further product documentation WebCAPS WebCAPS is a Web-based Computer Aided-Product Selection program and a web-version of WinCAPS. Available on Grundfos homepage, www.grundfos.com, WebCAPS offers detailed technical information dimensional drawings of each pump wiring diagrams of each pump. Click Catalogue and select a product from the extensive product catalogue. Click Replacement and select the right replacement pump based on the current installation. Click Literature to select and download Grundfos documentation by browsing the product ranges or performing a specific search. The literature includes: - Data booklets - Installation and operating instructions - Service instructions. Click CAD drawings to select and download CAD darwings in: -.stp -.dxf -.dwg Click Product search and select a product from the extensive product catalogue. Click Service to to find information on service kits and spare parts. If you are a registered user click Log in to: - save your settings - define and save your own units - save personalised information. Click Units and select your preferred units of measurement: - Default units - SI units - US units. Click Language and select your preferred language. Click the dropdown list to select the frequency WebCAPS Fig. 9 WebCAPS