WE SAY: REFILL PLEASE!
|
|
- Laurence Dickerson
- 6 years ago
- Views:
Transcription
1 multicontrol autofill MCA WE SAY: REFILL PLEASE! MULTICONTROL AUTOFILL SOLO MCA-S Ver.03/208-en
2 OPERATING PRINCIPLE Operating principle Make-up Losses within the system are mostly unavoidable. To ensure a smooth operation refilling from time to time is necessary. 3 contact controlled operation load V 2 P P L u 0 M Y5 Q P P 2 3 heat resp. cool generator storage tank MCA-G M multicontrol autofill solo MCA-S symbolic illustration multicontrol pressure maintenance 3 pressure controlled operation possible supply of multiple pressure maintenance devices load V 2 P P L u 0 M Y5 Q P P MAG heat resp. cool generator storage tank MCA-G M multicontrol autofill solo MCA-S membrane expansion vessel Legend symbolic illustration... make-up pipe... optional circulation pipe 2... expansion overflow pipe (from system return) 2... vessel overflow 3... expansion pressure pipe (to system return) 3... OPTIONAL connection for medium 0... suction pipe recirculation collecting pipe M... make-up pump Y5... switch mixer Q... water counter PLu... vessel pressure transmitter bottom P... system pressure transmitter 2
3 OPERATING PRINCIPLE Especially in air conditions, cold water systems, solar systems etc. a special medium mixture is used whereby a simple refill of fresh water is not possible. Multicontrol autofill solo MCA-S for automatic, amount controlled make-up of special media offers the possibility to refill a certain amount media mixture out of a storage tank is required. We recommend our multicontrol MCA-G vessels as storage tanks, but they don t have to be used compulsively. On site already existing vessels can possibly be used as storage tanks, because the needed vessel connection unit is always included in scope of delivery of the control unit multicontrol autofill MCA-S. With it the necessary level measurement in the storage tank as well as a permanent temperature measurement in the stored medium is realised. It is distinguished between the following operating modes: contact controlled operation: Thereby control of the MCA-S for example is carried out by a multicotrol pressure maintenance device. If the level within the pressure less expansion vessel falls below a certain minimum level an electric contact will request make-up. The make-up pump (M) supplies ready mixed system medium out of the storage tank (e.g. MCA-G) to the expansion vessel as long as it is refilled up to a preset level. On demand there is the possibility to supply several multicontrol pressure maintenance devices with make-up medium by one multicontrol autofil device. Thereto a make-up module is installed in every supplying pressure maintenance device and via a contact each of these devices can request make-up from the MCA-S. pressure controlled operation: Pressure controlled make-up takes place into the closed system directly. The system pressure is hold constant by a membrane expansion vessel (MAG), nevertheless it can fall by possible leaks. Assumed that the proper function of the MAG is given, make-up can be necessary. Therefore the vessel pressure transmitter (P) registers the actual pressure in the system and compares it with the adjusted set point. Decreases the pressure below the set value the makeup pump (M) starts. It pumps medium from the storage tank directly into the system. As soon as the set pressure is reached, the make-up pump (M) stops. The make-up amout is recorded by a water meter (Q) and compared with the maximum adjusted make-up amount. Is this amount exceeded the make-up stops and the make-up operation is locked. Only after verification and disengaging by the system support engineers, make-up can be activated again. Beside the amount controlled operating mode also a time controlled operating mode is available, which is advantageous in case of known and regular necessary make-up amounts. 3
4 OPERATING PRINCIPLE / DETAILS Within the storage tank (MCA-G) a vessel pressure transmitter (Plu) for level measurement is arranged. Level measurement bases on pressure measurement of the medium in the storage tank. Out of it the filling height (=vessel level) is determined (also not by weight measurement of load cells at the vessel). By undercutting a certain minimum vessel level make-up stops to protect the make-up pump (M) from running dry. Not before the storage tank (MCA-G) is filled again further make-up can take place. The storage tank is operated as open vessel to avoid negative pressure or overpressure. All connections are mounted on site, which implicates high flexibility because connection positions at the storage tank can be adapted to local conditions. Circulation function A circulation function is also included and after proper piping to the storage tank it can be activated in the settings. It offers the possibility to mix longer stored medium to antagonise settling out different media components at the storage tank bottom. Therefore in the working hydraulics an electromotive activated switch mixer (Y5) is built in already. To start the circulation functon it is activated by the electronic control, either in periodic intervals of directly before any make-up for an adjustment time, depending on the requirements of our costumer. For this purpose the switch mixer (Y5) is carried out as three way mixing valve that is adjusted in position make-up by default and moves to position circulating during the circulation process. Thereupon the make-up pump (M) is activated and circulates the medium via the switch mixer (Y5) from the tank connection unit back to the storage tank. Though all parts of the medium are well mixed again and afterwards make-up can take place. Medium recirculation For safety of financial reasons it can additionally be necessary to prevent a leakage of the particular system medium (e.g. via safety valves,...) and collect it again. For this purpose at the storage tank MCA-G a connection for a collecting pipe for media recirculation is provided. 4
5 DETAILS Details operator panel with four lines, illuminated plain text display enclosed electronic unit, optimally protected easily accessible cable glands, on request mountable to the left side always included four potential free contacts: - fault - warning - make-up in operation - device operation enabled on-site connections, on request convertible (right or left side) mounting holes in the base plate for fixing the device connection for medium recirculation from system safety valve(s) connection for circulation pipe corrosion resistance: base and piping made of stainless steel, brass/red brass storage tank made of high medium resistant synthetic material tank overflow incl. discharge hopper torsion resistant lattice-work made of zinc-plated steel tube tank emptying for any maintenance continuous temperature control transportable pallet for easy insertion 5
6 ACCESSORY Your great benefit: Convenient complete solution for make-up of special media from an external tank with connection for a collecting pipe for medium recirculation to the tank Special low-noise, self priming make-up pump From pioneer to number one: 45 years experience in pressure maintenance Company owned costumer service for technical service of your system throughout the product s life Accessory make-up / degassing connection accessory multicontrol autofill vessel MCA-G multicontrol autofill connection set G expansion modules / remote signalling multicontrol autofill connection set MC_ multicontrol expansion module analog signalling multicontrol expansion module binary signalling multicontrol expansion module binary signalling & remote reset multicontrol SMS module multicontrol bus modules general accessory multicontrol metal housing multicontrol contact temperature sensor incl. strap (diameter 5-40mm) multicontrol temperature sensor cable 0m, incl. immersion sleeve G/2", PN0 collecting pan, 3 spacer discharge hopper 50 with siphon For detailled information compare brochure multicontrol original accessory. Further products of our multicontrol series: expansion and pressure maintenance device picocontrol kompakt PCK expansion and pressure maintenance device multicontrol kompakt MCK pressure maintenance device multicontrol modular MCM pressure maintenance device topcontrol modular TCM pressure maintenance device multicontrol cool MCC 6
7 TECHNICAL DATA Technical data type elko-mat eder multicontrol autofill multicontrol autofill MCA storage tank MCA-G MCA-S-2.7 MCA-S-5.2 MCA-G640 MCA-G000 nominal content litre max. operating pressure unit (PN) bar 0 - max. upper working pressure bar 2,7 5,2 - max. operating pressure vessel (PN) bar - 0 max. temp. at connection point C 70 insertion tilted dimension mm voltage V/Hz 230/50 - max. electrical power kw 0,6 0,8 - fuse protection A 0 - dimensions A mm B mm C mm D mm E mm F mm G mm 50 - weight kg 49, connections " Rp 3/4-0 " Rp R " Rp R 2" - Geberit DN50 3" - R make-up pipe 0 suction pipe optional circulation pipe 2 vessel overflow 3 optional connection for medium recirculation collecting pipe Technical changes reserved! 0 Positions 0,, 2, 3 on the storage tank MCA-G are adapted to local conditions on site! 7
8 BETTER HEATING. SAFE BET. elko-flex eder plant complexity (generating capacity, static height, total content, working pressure) elko-mat eder picocontrol PCK elko-mat eder multicontrol MCK elko-mat eder multicontrol MCM elko-mat eder topcontrol TCM 8 ANTON EDER GMBH Stahl- & Kesselbau, Energie- & Verfahrenstechnik Bramberg Lienz Salzburg Wien Weyerstraße 350 A-5733 Bramberg Tel: 06566/7366 Fax: 06566/827 Mail: info@eder-heizung.at
WE SAY: THIS FITS TOGETHER
WE SAY: THIS FITS TOGETHER Original Accessory PERFECTLY! MULTICONTROL ORIGINAL ACCESSORY Ver. 11/2018-en 1 OVERVIEW expansion vessels designation fits for PCK MCK MCM TCM MCC MCA details elko-mat eder
More informationWE SAY: CLEANLY SEPARATED SYSTEMS = ELKO-MAT EDER!
elko-mat BACKFLOW PREVENTER WE SAY: CLEANLY SEPARATED SYSTEMS = ELKO-MAT EDER! Technical datasheet Ver.02/2017-en 1. Safety guidelines Follow the installation instructions Use the appliance according to
More informationFlamco Airfix D-E. Installation and operating instructions. 1999, Flamco eps
Airfix D-E 6442.eps GB Installation and operating instructions 1999, Exclusion of liability All operation and maintenance related technical information, data and instructions contained in these installation
More informationTB 42. Low maintenance effort saves on time and costs. High variability for vehicle types, construction and expan- sion options
TB 42 TB 42 commercial vehicle wash for automatic exterior cleaning. The 3-brush gantry allows a washing height of 4.25 m and offers total flexibility for different vehicle sizes and types. 1 Low maintenance
More informationGENO -Flushing Compressor Product Data Sheet F 02
GENO -flushing compressor 1988 K Fig. 1: GENO -flushing compressor 1988 K Designated application is suitable for the following fields of application: Flushing of pipes with water/air mix prior to the start-up
More informationOperating instructions Binary level sensor LI / / 2013
Operating instructions Binary level sensor LI51 UK 704367 / 02 02 / 2013 Contents 1 Preliminary note3 1.1 Symbols used 3 2 Safety instructions 3 3 Functions and features 4 3.1 Application area 4 3.2 Restriction
More informationGRUNDFOS DATA BOOKLET. Hydro Solo-E. Complete pressure boosting systems 50/60 Hz
GRUNDFOS DATA BOOKLET Complete pressure boosting systems 5/6 z Contents Product data Performance range 3 Operating conditions Inlet pressure Type key Product range 5 Construction 5 Installation 5 Mechanical
More informationAutomatic Balancing Valve Pressure difference controller with integrated flow limiter AB-PM DN
Data sheet Automatic Balancing Valve Pressure difference controller with integrated flow limiter AB-PM DN 40-100 Description AB-PM is ideal for staged installation and commissioning AB-PM is a combined
More informationECONORESS ELECTRONIC EPS & EPT - ENHANCED PRESSURISATION SET INSTALLATION OPERATION & MAINTENANCE DOCUMENTATION
ECONORESS ELECTRONIC EPS & EPT - ENHANCED PRESSURISATION SET INSTALLATION OPERATION & MAINTENANCE DOCUMENTATION OCT2010 STOKVIS ENERGY SYSTEMS 96R WALTON ROAD EAST MOLESEY SURREY KT8 0DL TEL: 020 87833050
More informationMobile High Pressure Compressor Unit for Compressing Air and Breathing Air. PE 250-TE with compressor control (optional equipment)
Mobile High Pressure Compressor Unit for Compressing Air and Breathing Air Types: PE 200-TE PE 250-TE PE 300-TE Production status: F02 PE 250-TE with compressor control (optional equipment) General Medium
More informationRadiator valves VDN1.. VEN1..
2 105 EN 215 Straight valves VDN1.. Angle valves VEN1.. ACVATIX TM Radiator valves VDN1.. VEN1.. DIN-norm, for 2-pipe heating systems Valve bodies made of brass, mat nickel-plated DN 10, DN 15 and DN 20
More informationCSO/STORMWATER MANAGEMENT. HYDROVEX HHV-E Vortex Driven Regulator
CSO/STORMWATER MANAGEMENT HYDROVEX HHV-E Vortex Driven Regulator HYDROVEX HHV-E VORTEX DRIVEN REGULATOR APPLICATION The hydro electronic HYDROVEX HHV driven regulator, type E is specially designed for
More informationRadiator valves VDN2.. VEN2.. VUN2..
2 106 EN 215 Straight valves VDN2.. Angle valves VEN2.. Reverse angle valves VUN2.. ACVATIX TM Radiator valves VDN2.. VEN2.. VUN2.. NF norm, for 2-pipe heating systems Valve bodies made of brass, mat nickel-plated
More informationFlamco Flamco-Fill STA Flamco-Fill STM
STA STM Typ STA 5936 Typ STM 5937 GB Installation and operating instructions 1999, 2 Contents GB UK Limited P.O. Box 9, Washway Lane, St. Helens, Merseyside WA10 6FE United Kingdom Telephone: 01744 744744
More informationerc-o 2 -tech Ò innovative gas systems Markwerbener Str Weißenfels Germany
Compart Umwelttechnik GmbH erc-o 2 -tech Ò innovative gas systems Markwerbener Str. 24 06667 Weißenfels Germany Phone: 0049 (0) 3443/2901-0 Fax: 0049 (0) 3443/2901-12 Mail: compart-weissenfels@t-online.de
More informationInstallation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units
Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units Models: EPS Single Pump EPT Twin Pump EPS-HP EPT-HP Single Pump High Pressure Twin Pump High Pressure
More informationOverview of types. T5-R B2/R B2 en v Subject to changes 1 / 4. k vs (Sequence 2)
Technical data sheet R3015-..-..-B2 / R3020-..-..-B2 Characterised control valves, 6-way, with internal threads Two sequences (cooling/heating) With a rotary actuator 90 Water-side switching or modulating
More informationTightness controls TC 1 3 and TC 4
Tightness controls TC 1 3 and TC 4 Test of both safety valves Short test period thanks to logical decision-making in the program sequence Adjustable test period which can be adapted to different systems
More informationSonoMeter 30 Energy Meters
Data Sheet SonoMeter 30 Energy Meters Description The Danfoss SonoMeter 30 is a range of ultrasonic, compact energy meters intended for measuring energy consumption in heating and cooling applications
More informationSPIROVENT VACUUM DEGASSERS
SPIROVENT VACUUM DEGASSERS S P I R O V E N T A I R S U P E R I O R FLUID AND GAS There are always a certain amount of gasses in a fluid, dependent on pressure and temperature. The British physicist William
More informationAirfix. Flamco. Flamco. Pressure expansion vessels for sanitary appliances and potable water systems AIRFIX A AIRFIX D AIRFIX D-E
AIRFIX EXPANSION VESSELS Flamco Airfix Pressure expansion vessels for sanitary appliances and potable water systems AIRFIX A AIRFIX AIRFIX -E Flamco Edition 2005 / EXP Flamco Flamco offers you a wide choice
More informationbrands you trust. DEPA DH Next Generation Air Operated Double Diaphragm Pumps
brands you trust. DEPA DH Next Generation Air Operated Double Diaphragm Pumps Features and Benefits DEPA DH Next Generation Air Operated Double Diaphragm Pump Series DH15, DH25 and DH40 are made of cast
More informationDIAPHRAGM VACUUM PUMPS AND COMPRESSORS
DIAPHRAGM VACUUM PUMPS AND COMPRESSORS DATASHEET N 143 N 143 SP.12 E Concept The diaphragm pumps from KNF are based on a simple principle an elastic diaphragm, ixed on its edge, moves up and down its central
More informationSIHI LPH-X - Liquid Ring Compressors
- Liquid Ring Compressors LPH 50523 LPH 60527 Pressure range: Suction volume range: 0.2 to 1.5 bar 260 to 780 m³/h CONSTRUCTION Sterling SIHI liquid ring compressors are displacement compressors with a
More informationAirfix D-E-B Installation and operating instructions
www.flamco.nt-rt.ru Airfix D-E-B Installation and operating instructions Dear Customer, With the Airfix D-E-B membrane expansion vessel you have acquired a Flamco quality product. This expansion vessel
More informationAUTOMATIC HOSE TEST UNIT, TYPE SPU
VALVES AND FITTINGS UP TO 14,000 BAR TEST AND CONTROL EQUIPMENT H IGH PRESSURE TECHNOLOGY AUTOMATIC HOSE TEST UNIT, TYPE SPU Pressure range from 1 up to 10,000 bar User-friendly touch panel operation HIGH-PRESSURE
More informationDifferential pressure and flow controller (PN 16) AVPQ - return mounting, adjustable setting
Data sheet Differential pressure and flow controller (PN 16) AVPQ - return mounting, adjustable setting Description AVPQ is a self-acting differential pressure and flow controller primarily for use in
More informationModel MTB-ASME Vertical Bladder Tanks
DATA SHEET Model MTB-ASME Vertical Bladder Tanks Features n UL Listed for use with various proportioners and foam concentrates n 175 psi (12.1 bar) maximum allowable working pressure (design pressure)
More informationDIAPHRAGM VACUUM PUMPS AND COMPRESSORS
DIAPHRAGM VACUUM PUMPS AND COMPRESSORS DATASHEET N 2400 N 2400.15 ST.9 E Concept The diaphragm pumps from KNF arebased on a simple principle an elastic diaphragm, ixed on its edge, moves up and down its
More informationDIAPHRAGM VACUUM PUMPS AND COMPRESSORS
DIAPHRAGM VACUUM PUMPS AND COMPRESSORS DATA SHEET N 186 N 186.1.2 ST.12 E Concept The diaphragm pumps from KNF are based on a simple principle an elastic diaphragm, ixed on its edge, moves up and down
More informationModel MTB-ASME Vertical Bladder Tanks
DATA SHEET Model MTB-ASME Vertical Bladder Tanks Features n UL Listed for use with various proportioners and foam concentrates n 175 psi (12.1 bar) maximum allowable working pressure (design pressure)
More informationHydraulic hand spindle pump Models CPP1000-M, CPP1000-L
Calibration Hydraulic hand spindle pump Models CPP1000-M, CPP1000-L WIKA data sheet CT 91.05 for further approvals see page 2 Applications Calibration service companies and service industry Calibrations
More informationV5001P. Kombi-Auto Differential Pressure Control Valve. Product specification sheet
V5001P Kombi-Auto Differential Pressure Control Valve Product specification sheet Content Application...1 Special Features...1 Valve Efficiency...1 Technical Data...2 Construction...2 Materials...2 Method
More informationPressure surge absorption
Pressure surge absorption Product range for drinking water, waste water and the chemical industry With remote monitoring, everything is fully under control. Willy Zahnd, WARET AG PRESSURE SURGE ABSORPTION
More informationExpert Hydrostatic Level Transmitters
Expert Hydrostatic s General Features MJK Expert hydrostatic level transmitters are designed for level measurement by submerging the transmitter in open channels, drains and tanks. Expert hydrostatic level
More informationPressure Reducing Valve DMV 755
Pressure Reducing Valve DMV 755 Nominal size DN 10 50 Nominal size 3/8 2 Nominal pressure PN 10 bar Features pressure setting range 1 to 9 bar control valve for reliable reduction of system pressures to
More informationExpansion vessels for solar systems
Expansion vessels for solar systems 14 solar plus The Zilmet group Zilmet, an interationally operating company, has with 45 years experience grown to be the biggest European producer of expansion vessels.
More informationInstallation and commissioning instructions 255 series and 256 series
Installation and commissioning instructions 255 series and 256 series Table of contents 1 General information... 3 1.1 About these instructions... 3 1.2 About this product... 3 1.3 Appropriate usage...
More informationOverflow valves Type OFV REFRIGERATION AND AIR CONDITIONING. Technical leaflet
Overflow valves Type OFV 20-25 REFRIGERATION AND AIR CONDITIONING Technical leaflet Contents Page Introduction....................................................................................... 3 Features...........................................................................................
More informationDynamic Valve Type RA-DV Pressure Independent Radiator Valve
Dynamic Valve Type RA-DV Pressure Independent Radiator Valve Application RA-DV straight version RA-DV is a series of pressure independent radiator valves, designed for use in 2-pipe heating systems together
More informationSelf-operated Pressure Regulators for special applications
Self-operated Pressure Regulators for special applications Type 2357-31 Pressure Build-up Regulator with safety function and integrated excess pressure valve Application Pressure regulators for cryogenic
More informationInstruction Manual Dräger MSI P7 and MSI P7 plus
Dräger MSI GmbH Rohrstraße 32 58093 Hagen Tel.: +49-2331 / 9584-0 Fax: +49-2331 / 9584-29 e-mail: info@draeger-msi.de D 923; Edition 2011-01-01 Content 1. General Hints Page 4 2. The Instrument 2.1 Front
More informationGMD20..NL, GMD30..NL* GHV20..NL, GHV30..NL* GHV40..NL, GTKS20..NL* Series
GMD20..NL, GMD30..NL* GHV20..NL, GHV30..NL* GHV40..NL, GTKS20..NL* Series Fixed and Variable speed Booster sets Maximum operating pressure 16 bar. Flow rates up to 56 m 3 /h 50 Hz * FOR NEDERLAND MARKET
More informationCENTRAL GAS SUPPLY SYSTEMS : CYLINDER BATTERIES AND HIGH PRESSURE HOSES
P0170E-1.DOCX/08.16/MG CENTRAL GAS SUPPLY SYSTEMS : CYLINDER BATTERIES AND HIGH PRESSURE HOSES With a Central Gas Supply System, individual work places or gas take-off stations are supplied with gas through
More informationSystem Pressure Manager Standard & System Pressure Manager Plus
System Pressure Manager Standard & System Pressure Manager Plus Installation, Commissioning & Servicing Instructions Note: THESE INSTRUCTIONS MUST BE READ AND UNDERSTOOD BEFORE INSTALLING, COMMISSIONING,
More informationDIAPHRAGM GAS SAMPLING PUMPS
DIAPHRAGM GAS SAMPLING PUMPS DATA SHEET E 059 N 0150 AP.9E N 0150.3 AP.9E N 0150 SP.12E Double diaphragm pump Concept The diaphragm pumps from KNF are based on a simple principle an elastic diaphragm,
More informationHorizontal Bladder Tanks
DATA SHEET Horizontal Bladder Tanks Features UL Listed and FM Approved for use with various ANSUL proportioners and foam concentrates 175 psi (12.1 bar) maximum allowable working pressure (design pressure)
More informationbetter measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars.
Simply a question of better measurement SCHMIDT Flow Sensor SS 20.261 The cost-effective alternative in pressurised systems up to 10 bars. Compressed air technology Industrial processes A cost analysis
More informationOPERATING MANUAL CHEMTRAC 840M MANUAL RETRACTABLE PROCESS HOLDER
OPERATING MANUAL CHEMTRAC 840M MANUAL RETRACTABLE PROCESS HOLDER Table of contents 1 Security and safety measures... 5 1.1 General safety instructions... 5 1.2 Intended use... 5 1.3 Danger zones and residual
More informationUBEC 1AT. AUTO TANK Fill System Installation, Operation, & Setup Instructions
Document Number: XE-ATA5PM-R1A UBEC 1AT AUTO TANK Fill System 08899155 Installation, Operation, & Setup Instructions Rev170906-EB-FRC PHYSICAL: 1302 WEST BEARDSLEY AVE ELKHART, IN 46514 WWW.ELKHARTBRASS.COM
More informationWATER MADE EASY MARINE ENERGY MUNICIPAL INDUSTRIAL
Capital Controls Series 71V3000 The Series 71V3000 electrically-heated vaporizer automatically vaporizes and superheats liquid chlorine, sulfur dioxide or ammonia at a rate controlled by the gas feed system.
More informationPneumatic high-pressure controller Model CPC7000
Calibration technology Pneumatic high-pressure controller Model CPC7000 WIKA data sheet CT 27.63 Applications Healthcare and avionics industry Industry (laboratory, workshop and production) Transmitter
More informationAutomatic Control Unit. Cervomatic EDP.2. Type Series Booklet
Automatic Control Unit Cervomatic EDP.2 Type Series Booklet Legal information/copyright Type Series Booklet Cervomatic EDP.2 All rights reserved. The contents provided herein must neither be distributed,
More informationVertical Bladder Tanks
DATA SHEET Vertical Bladder Tanks Features UL Listed and FM Approved for use with various ANSUL proportioners and foam concentrates 175 psi (12.1 bar) maximum allowable working pressure (design pressure)
More informationModel MTB-ASME Horizontal Bladder Tanks
DATA SHEET Model MTB-ASME Horizontal Bladder Tanks Features n UL Listed and FM Approved for use with various proportioners and foam concentrates n 175 psi (12.1 bar) maximum allowable working pressure
More informationRemeha Quinta Cascade guide
Technical information Remeha Quinta Cascade guide Cascade guide Cascade systems 2 Remeha Quinta Cascade guide TABLE OF CONTENTS FOREWORD 4 1 GENERAL DESCRIPTION OF CASCADE SYSTEMS 4 1.1 Optimum number
More informationEnerVal. Technical data litre storage capacity. Buffer storage vessels
EnerVal Buffer storage vessels Technical data 200-10000 litre storage capacity Contents Title Page number EnerVal (200-2000) Description 3 Part No. 4 Technical data 6 Dimensions 7 EnerVal G (1000-10000)
More informationArmatures for analytical probes
Armatures for analytical probes For many different types of installations and applications Large range of probe holders General purpose, water treatment, food & beverage, pharmaceutical applications Type
More informationOperating Manual FSV, FSÖV, SSVF
Contents 1. General Remarks... 1 1.1. Marking... 2 1.2. Tightness of the Quick-Closing Valve... 2 1.3. Medium... 2 1.4. Ambient and Medium Temperature... 3 1.5. Vibrations... 3 1.6. Pipe Tensions... 3
More informationType overview. R B2 en-gb subject to changes 1
Technical data sheet R30..-..-..-B2 Characterised control valve, 6-way, Internal thread Two sequences (cooling/heating) with one 90 rotary actuator Switching or modulating control on the water side of
More informationAutomatic balancing valves ASV
Automatic balancing valves ASV ASV-P ASV-PV ASV-PV ASV-PV ASV-I ASV-M 15-40 15-40 50 65-100 15-50 15-50 Description / Application ASV balancing valves are used for dynamic hydronic balance in heating and
More informationBOSS PULISCI PROVA IMPIANTI MEDIA
BOSS PULISCI PROVA IMPIANTI MEDIA Pump for power flushing operations and removal of impurities, suitable for hydraulic, solar, floor systems and for cooling circuits of medium size. Suitable for buildings,
More informationDifferential pressure controller (PN 16) AHP - return mounting, adjustable setting
Data sheet Differential pressure controller (PN 16) AHP - return mounting, adjustable setting Description DN 15-40 DN 50 DN 65-100 AHP is a self-acting differential pressure controller primarily for use
More informationPressurisation Systems. Variomat. Pump Controlled Pressurisation Systems. Pressure maintenance Deaeration Water make-up. For Control Touch:
Variomat Pump Controlled Pressurisation Systems Pressure maintenance Deaeration Water make-up For Control Touch: 17 Control Unit Control Basic Control Basic S Control Touch 2-line LCD display 8 control
More information6-way characterised control valves DN15 / DN 20 / DN 25
6-way characterised control valves DN15 / DN 20 / DN 25 Table of contents Introduction 2 Project planning 2 Structure of the 6-way characterised control valves 2 Range of use 2 Characteristic curve 3 Flow
More informationCCS240 and CCS241. Technical Information. Sensors for chlorine dioxide Amperometric, membrane-covered sensors for installation in the CCA250 assembly
Technical Information CCS240 and CCS241 Sensors for chlorine dioxide Amperometric, membrane-covered sensors for installation in the CCA250 assembly Application Chlorine dioxide is used for disinfection
More informationph measuring system for hygienic process applications
ph measuring system for hygienic process applications Sterile design, CIP-compatible, in-line sterilizable Extremely robust and unbreakable construction Extremely long service life Long calibration intervals
More informationCrab and Lobster Live Holding System Part II (Water Pumps, Air Pumps and Pipework)
Crab and Lobster Live Holding System Part II (Water Pumps, Air Pumps and Pipework) 1990/2/SF/AM The increased demand for crabs and lobsters, and the requirement to export live shellfish has led to the
More informationVACUUM REGULATORS CONTENTS
CAD drawing data catalog is available. ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS CONTENTS Small Regulators Features 759 Specifications, Order Codes, Flow Rate
More information6-way characterised control valves DN15 and DN 20
6-way characterised control valves DN15 and DN 20 Table of contents Introduction 2 Project planning 2 Structure of the 6-way characterised control valves 2 Range of use 2 Characteristic curve 3 Flow direction
More informationGas powered stop valves, type GPLX REFRIGERATION AND AIR CONDITIONING. Technical leaflet
Gas powered stop valves, type GPLX 80-150 REFRIGERATION AND AIR CONDITIONING Technical leaflet Technical leaflet Gas powered stop valves, type GPLX 80-150 Contents Page Introduction........................................................................................3
More informationPneumatic high-pressure controller Model CPC7000
Calibration technology Pneumatic high-pressure controller Model CPC7000 WIKA data sheet CT 27.63 Applications Automotive and avionics industry Industry (laboratory, workshop and production) Transmitter
More informationHBLT-A1 LIQUID LEVEL SENSOR
Instruction manual HBLT-A1 LIQUID LEVEL SENSOR for measuring liquid level in refrigerant vessels Instruction manual HBLT - A1 - Liquid level Transmitter (HBLT-A1-008-UK) 1 / 16 Contents Safety instructions...
More informationDosing & Granudos. Controllers. Chemical Storage. Chemical. Dosing &
C hemical Dosing & Controllers Granudos Chemical Dosing & Controllers Controllers Chemical Storage Granudos Granudos 10-CPR Touch Granudos 10-CPR Touch swimming pool disinfection system using IQ Granu-Chlor
More informationBIMBAR INFLATABLE PACKERS AND ACCESSORIES
BIMBAR INFLATABLE PACKERS AND ACCESSORIES Geopro supplies a complete range of inflatable packers in nine different diameters from 28 up to 170mm. All our packers made of BIMBAR rubber technology are reinforced
More informationService Test Unit for ROSS Proportional Valves RESK
Service Unit for Proportional Valves Page 1 Technical Description ROSS 04.08.2015 Service Test Unit for ROSS Proportional Valves Technical Description V 1.0 / 2015 RESK 4591.40 For all Prop Valve Models
More informationExpansion Vessels for Potable Installations
4. Expansion Vessels for Potable Installations Domestic installations lose millions of litres of potable water due to expansion water leaking from the vent and expansion pipe. Flamco s Airfix diaphragm
More informationFlamco Flexcon M-P Pump automat
Flexcon M-P Pump automat 0664 Flex MP-eps GB Installation and operating instructions 1999, Flamco 2 Installation and operating instructions Flexcon M-P pump automat Dear customer, GB With the purchase
More information3-Way Safety Block DSV
3-Way Safety Block DSV DSV 10 - M DSV 10 - M - T-ball DSV 10 - EY 1. Description 1.1. GENERAL The 3-way safety block is used to shut off and discharge hydraulic accumulators or consumers. It complies with
More informationFlamco
EN 7-30 Flamco www.flamcogroup.com EN 7-30 INSTLLTION ND OPERTING INSTRUCTIONS Contents Page 1 General 3 1.1 bout this manual 3 1.2 Other supplied documentation 3 1.3 Use of Flamco products 3 1.4 Further
More informationHydraulic comparison test pump Models CPP1000-X, CPP1600-X
Calibration Hydraulic comparison test pump Models CPP1000-X, CPP1600-X WIKA data sheet CT 91.12 for further approvals see page 2 Applications Calibration service companies and service industry Maintenance
More informationOverflow valves Type OFV Type OFV-SS REFRIGERATION AND AIR CONDITIONING. Technical leaflet
Overflow valves Type OFV 20-25 Type OFV-SS 20-25 REFRIGERATION AND AIR CONDITIONING Technical leaflet Contents Page Introduction.......................................................................................
More informationFull-Vacuum Chlorinator C 2212 MB / 1
MB 2 04 12 / 1 Purpose of full-vacuum chlorinators Chlorine gas is important for the disinfection of potable and swimming pool water but also represents a source of danger as far as handling, transportation
More informationSonoSelect 10 and SonoSafe 10 energy meters
SonoSelect 10 and SonoSafe 10 energy meters Description The Danfoss SonoSelect 10 and SonoSafe 10 are ultrasonic compact energy meters intended for measuring energy consumption in heating and cooling applications
More informationINDUSTRIAS IBAIONDO, HYDROPNEUMATIC TANKS
IBAIONDO, HYDROPNEUMATIC TANKS IBAIONDO, INTRODUCTION Hydropneumatic tanks are designed to be used in potable water supply installations as a part of the pressure booster set in order to ensure the adequate
More informationVSL MINING & TUNNELING SYSTEMS VSL. mining and tunneling
VSL MINING & TUNNELING SYSTEMS VSL mining and tunneling VSL Mining & Tunneling Bolt systems VSL offers three type of bolting system for the mining & Tunnelling industry VSL-S Solid Threaded bolts. Continuous
More informationTypes and approvals. Page 1/6. Data Sheet
Page 1/6 Panel-mounting Thermostats EM Series as: Protection temperature monitor STW (STB) Protection temperature limiter STB tested to DIN 3440 and Pressure Equipment Directive 97/23/EC Brief description
More informationDM01. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05
Battery Powered Stainless Steel Sensor class 0.05 Nominal pressure from 0 00 mbar up to 0... 00 bar Special characteristics modular sensor concept data logger graphic display stainless steel housing Ø
More informationCCT-7320/ROC-2313 Reverse Osmosis Controller
CCT-7320/ROC-2313 Reverse Osmosis Controller 1 General The instrument is a combined control instrument of a reverse osmosis controller and an on-line conductivity instrument. It can perform the operation
More informationECL Comfort 110, application 131 (valid as of software version 2.00)
Operating Guide ECL Comfort 110, application 131 (valid as of software version 2.00) English version www.danfoss.com How to navigate? Adjust temperatures and values. Switch between menu lines. Select /
More information2-port and 3-port seat valves, PN16
s 4 47 VVI47 VXI47 CVTIX 2-port and 3-port seat valves, PN6 with internally threaded connections VVI47.. VXI47.. ronze valve body CC49K (Rg5) DN 5...5 k vs 2.5...4 m 3 /h Internally threaded connections
More informationETd 04. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. Type: ETd 04. class 0.05
Battery Powered Stainless Steel Sensor class 0.05 Nominal pressure from 0 100 mbar up to 0... 400 bar Special characteristics modular sensor concept data logger graphic display stainless steel housing
More informationELADOS EDP L Diaphragm Metering Pump Type
ELADOS EDP L Diaphragm Metering Pump Type 04800-06700 Motor-driven diaphragm pump with integrated frequency converter High reserves due to a powerful asynchronous motor High flexibility due to variably
More informationIDL01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05
IDL0 Battery Powered Precision Digital Gauge for Leak Testing Stainless Steel Sensor class 0.05 Nominal pressure from 0 00 mbar up to 0... 00 bar Special characteristics modular sensor concept data logger
More informationKGW - ISOTHERM. Operating Instructions. Level controlling device for liquid nitrogen LEVEL CONTROL LN2
KGW - ISOTHERM Germany 76185 Karlsruhe Gablonzer Straße 6 Tel. 0049 / 721 / 95897-0 Fax. 0049 / 721 / 95897-77 email:info@kgw-isotherm.de Internet: www.kgw-isotherm.de Operating Instructions Level controlling
More informationTA-FUSION-P. Combined control & balancing valves Pressure independent combined balancing and control valves with independent EQM characteristics
TA-FUSION-P Combined control & balancing valves Pressure independent combined balancing and control valves with independent EQM characteristics IMI TA / Control valves / TA-FUSION-P TA-FUSION-P These innovative
More informationMANUAL KPS Pressure Control Valve
TetraTec Instruments GmbH Gewerbestrasse 8 71144 Steinenbronn Deutschland E-Mail: info@tetratec.de Tel.: 07157/5387-0 Fax: 07157/5387-10 MANUAL Pressure Control Valve *** VERSION 1.0 *** Update: 17.11.2006
More informationGripping rotary modules
Gripping rotary modules Gripping rotary modules GRIPPING ROTARY MODULES Series Size Page Gripping rotary modules RP 314 RP 1212 318 RP 1216 322 RP 1520 326 RP 2120 330 RP 2128 334 RC 338 RC 1212 342 RC
More informationMechanical Pressure Measurement
Mechanical Pressure Measurement Differential Pressure Gauges Model GDP, Universal Version, with Diaphragm Element High Overpressure Safety PN 40, 100, 250 or 400 Applications Differential pressure measurement
More informationBall valve HKSF-W100. Ball valve HKSF-W100. RMA Kehl GmbH & Co. KG Oststrasse 17 D Kehl / Germany
Ball valve HKSF-W100 RMA Kehl GmbH & Co. KG Oststrasse 17 D-77694 Kehl / Germany info@rma-kehl.de www.rma-armaturen.de 1 Design Features: RMA-ball valves type HKSF-W are fully welded and completely maintenance-free
More information