Accessories. Orifice flow meters with measuring ring chambers POP-U-S (E5719 rev /06/2014)

Similar documents
Mixers. Venturi proportional mixers EMM & EMMTR (E2351 rev /07/2017)

Accessories. Differential pressure gauges for air and gas MAG-A & MAG-G (E5275 rev /04/2010)

Accessories. Combustion ratio regulators FCR-REG-II (E5106 rev /04/2014)

Accessories. Flexible Compensators FN & ESA FLEX & INOXESTENS (E5603 rev /03/2015)

Accessories. Pressure regulators Zero Governors (EN88/1) BZR-REG-II (E5102 rev /11/2017)

Accessories. Differential pressure gauges for air and gas MAG-A & MAG-G (E5275 rev /04/2010)

Burners. Blast pilots PBC & PBST (E3280 rev /04/2018)

THE WAY THE VENTURI AND ORIFICES WORK

Electronics. Portable differential pressure gauge ESA DPG-E (E7220 rev /10/2015)

North American Orifice Metering System

HUPF Series DESCRIPTION APPLICATION INSTRUCTION SHEET GAS PRESSURE REGULATOR WITH INCORPORATED FILTER EN1C-0003NL05 R1205.

Serie 06-M6. Swing wafer check valve. made in. Application fields. Check valves E U R O P E WATER CONDITIONING INDUSTRY

Gas Pressure Regulator HON 200

Target disk flowmeter Series DP. Instructions manual DP65 DP500. R-MI-DP Rev.: 4 English version

PRESSURE REGULATORS AND FLOWMETERS, ALL MEDICAL GASES

CHAPTER 5 COMBUSTION AND NOZZLES PILOT BURNER V F. Fig. 11B FIG11A

V5197A. Firing Rate Gas Valve APPLICATION FEATURES PRODUCT HANDBOOK

Integral type Differential pressure flowmeter VNT Series

INSTRUCTION MANUAL Pressure Relief Device LPT

6301 TYPE CAST IRON SAFETY VALVES

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25

Un-Pressurized Orefice Fittings FIO EZ. Parts List and Operation Instructions TECHNICAL MANUAL. Dn 2-6 Class Lbs

Differential pressure and flow controller (PN 16) AVPQ - return mounting, adjustable setting

776 Cryogenic Safety Valve

Self-operated Pressure Regulators for special applications

ATS430 turbidity sensor Retractable insertion assembly

Incorrect installation, adjustment, or misuse of this burner could result severe personal injury, or substantial property damage.

Ball Float Steam Trap UNA 43 PN 16/CL 125/JIS 10K UNA 46 PN 40/CL 150/CL 300/JIS 10K/JIS 20K DN 80, 100, 150, 3", 4", 6"

VALVES HIDROMATIC VALVE.

THE BP-301 SERIES. Operating and Service Manual. Series includes all variants of BP-301 (LF 0.1Cv / MF 0.5Cv)

Gas Pressure Regulator HON 300

Series MG Mixing Tubes

FPD175 Compact orifice carrier assembly

XDF BURNERS DUAL FUEL EXCESS AIR BURNER FEATURES DESCRIPTION EXCESS AIR OPERATION

THE HF-300 SERIES. Operating and Service Manual. Series includes all variants of HF-300/301

CARTRIDGE FILTERS TECHNICAL MANUAL MT 080. Installation, commissioning and maintenance instructions. 08/02 Edition

AREA VALVE SERVICE UNITS

PRESSURE REDUCING VALVE RP45 (EN)

Serie ECO 3T. Threaded end back flow preventer with controllable reduced pressure zone. made in. Application fields. Protection E U R O P E

Filling valves AL, ALM Series Automatic filling units ALOMDIW, ALOMDNW Series

VALFONTA INSTRUCTIONS: OPERATION AND INSTALLATION PRESSURE REDUCING VALVE MODEL PRV44

Differential Pressure Regulator Type Type 45-6 (0.1 to 1 bar, DN 15) Mounting and Operating Instructions EB 3226 EN

THE MF-400 SERIES. Operating and Service Manual. Series includes all variants of MF-400/401

AVP-F. p setting range (bar) Code No. 003H6200

Differential Pressure Control Valve (DPCV)

SAPAG. Safety valves, type 5700 Storage, Use, Operation and Maintenance Instructions. IMPORTANT NOTICE

Ball Float Steam Trap UNA 45 MAX, UNA 46 MAX, UNA 46A MAX PN 40/Class 300 DN 40, 50, 65

HANDBOOK SAFETY DEVICES. Ed SAFETY DEVICES DS-ED 01/ ENG 1

Differential pressure controller (PN 25) AVP - return and flow mounting, adjustable setting

Size : Connection Ends : Min Temperature : Max Temperature : Materials : Cast iron body

Pressure regulators. Introduction. TR Head. 3 ways body Dival

Modulating Valves for Atmospheric, Infrared, and Direct Fired Burners

STAINLESS STEEL LOW PRESSURE REDUCING VALVE LPRV ELITE

POP Safety Valve. POP Safety Valve INTRODUCTION DEFINITIONS

Manual Actuated Boiler Blowdown Valves

VGG... VGF... VGH... Gas Valves. Building Technologies HVAC Products VGG... VGF... VGH...

better measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars.

VGG... VGF... VGH... Gas Valves. Siemens Building Technologies HVAC Products VGG... VGF... VGH...

Materials : Stainless steel ASTM A351 CF8M

Materials : Forged carbon steel A105N

A REVIEW OF THE 2000 REVISIONS TO ANSI 2530/API MPMS 14.3/AGA REPORT NO. 3 - PART2 Paul J. LaNasa CPL & Associates

VGG... VGF... VGH... Gas Valves. Building Technologies HVAC Products VGG... VGF... VGH...

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly.

DN 50 REGULATOR SUTON 5000A1 REGULATOR SUTON 5000D1

Spiratec ST14, ST16 and ST17 Sensor Chambers and sensors

VGF... VGH... Building Technologies Division Infrastructure & Cities Sector VGG... VGF... VGH...

GM-7000 Series CE Approved Gas Control Valve

Liquid level regulating valves Types PMFL / PMFH and SV

Serie ECO 3F. Flanged back flow preventer with controllable reduced pressure zone. made in. Application fields. Protection

SERIES 500 VARIABLE RANGE PNEUMATIC DIFFERENTIAL PRESSURE TRANSMITTER

Materials : Brass body dezincification-resistant up to DN1 1/4

Gas Filters DN15 DN300. delta-elektrogas.com EE151 03/17

MT-239-E ENGLISH PRESSURE REGULATOR STAFLUX MINI TECHNICAL MANUAL INSTALLATION, COMMISSIONING AND MAINTENANCE INSTRUCTIONS

SCA Series Inverted Bucket Steam Traps

Materials : Forged carbon steel A350 LF2

Materials : Forged carbon steel A105N

Hydraulic comparison test pump Models CPP1000-X, CPP1600-X

GM Series Dual-Block Multi-Function Gas Control Valves

Norval Pressure Regulators

The Discussion of this exercise covers the following points:

OFFICINE OROBICHE S.p.A. 1/9

Instruction Manual Contact Pressure Vacuum Gauge

Aperval Pressure Regulators

Size : Ends : Min Temperature : Max Temperature : Materials : Cast iron body

Dual Solenoid Gas Valve Installation

Self-operated Regulators Accessories Differential Pressure and Flow Regulators

Instruction Manual SB02, SB03, SB04 All metal flow limiter

Flanged pressure reducer/stabilizer VRCD

2-step solenoid valve Type ICLX

2-step solenoid valve Type ICLX

TECHNICAL DATA Q = C. v P S. 2 Model G-2000 Dry valve. Page 1 of 13

High Pressure Inlet Kits for CONCOA BlendMites and BlendMasters

Installation, Operation and Maintenance Instructions for Pacific PA Non-Storage Heat Exchanger

VR46.5V(A)/VR86.5V(A) SERIES

Mounting and Operating Instructions EB 9520 EN. Differential Pressure and Flow Meter Media 05

RHPS Series RD(H)F40 User Manual. Read the complete manual before installing and using the regulator.

This document is a preview generated by EVS

Instruction Manual Differential Pressure Transmitter

ACCESSORY KIT INSTALLATION INSTRUCTIONS

Engineering Data Sheet

Transcription:

Accessories Orifice flow meters with measuring ring chambers POP-U-S (E5719 rev. 06-25/06/2014)

GENERAL WARNINGS: GENERAL NOTES: ¾ All installation, maintenance, ignition and setting must be performed by qualified staff, respecting the norms present at the time and place of the installation. ¾ To avoid damage to people and things, it is essential to observe all the points indicated in this handbook. The reported indications do not exonerate the Client/User from observing general or specific laws concerning accidents and environmental safeguarding. ¾ The operator must wear proper DPI clothing (shoes, helmets...) and respect the general safety, prevention and precaution norms. ¾ To avoid the risks of burns or high voltage electrocutaion, the operator must avoid all contact with the burner and its control devices during the ignition phase and while it is running at high temperatures. ¾ All ordinary and extraordinary maintenance must be performed when the system is stopped. ¾ To assure correct and safe use of the combustion plant, it is of extreme importance that the contents of this document be brought to the attention of and be meticulously observed by all personnel in charge of controlling and working the devices. ¾ The functioning of a combustion plant can be dangerous and cause injuries to persons or damage to equipment. Every burner must be provided with certified combustion safety and supervision devices. ¾ The burner must be installed correctly to prevent any type of accidental/undesired heat transmission from the flame to the operator or the equipment. ¾ The performances indicated in this technical document regarding the range of products are a result of experimental tests carried out at ESA-PYRONICS. The tests have been performed using ignition systems, flame detectors and supervisors developed by ESA-PYRO- NICS. The respect of the above mentioned functioning conditions cannot be guaranteed if equipment, which is not present in the ESA-PYRONICS catalogue, is used. DISPOSAL: To dispose of the product, abide by the local legislations regarding it. ¾ In accordance to the internal policy of constant quality improvement, ESA-PYRONICS reserves the right to modify the technical characteristics of the present document at any time and without warning. ¾ It is possible to download technical sheets which have been updated to the latest revision from the www.esapyronics.com website. ¾ The products manufactured by ESA-PYRONICS have been created in conformity to the UNI EN 746-2:2010 Norms: Equipment for industrial thermal process - Part 2: Safety requirements for combustion and the movement and treatment of combustible elements. This norm is in harmony with the Machine Directive 2006/42/CE. It is certified that the products in question respect all the requirements prescribed by the above mentioned Norms and Directives. ¾ Certified in conformity with the UNI EN ISO 9001 Norm by DNV GL. EN5167-2 EN331 Headquarters: Esa S.p.A. Via Enrico Fermi 40 24035 Curno (BG) - Italy Tel +39.035.6227411 Fax +39.035.6227499 esa@esacombustion.it CERTIFICATIONS: Fuid measurement via EN differential pressure devices placed inside full circular pipe sections - Part 2: Diaphragms Ball valves and male cone-shaped valves with closed ends, manually controlled valves, for gas systems in buildings. The products comply with the requirements of the Eurasian market (Russia, Belarus and Kazakhstan) and are exempt from the EAC certification ref. Doc. 01-11/437 CONTACTS / SERVICE: www.esapyronics.com International Sales: Pyronics International s.a. Zoning Industriel, 4ème rue B-6040 Jumet - Belgium Tel +32.71.256970 Fax +32.71.256979 marketing@pyronics.be www.esapyronics.com 2

The POP-U-S calibrated flow meters are instruments that measure the fluid flow in piping according to the EN5167-2 Norm. They are available in different materials and sizes according to the type of fluid and flow that needs to be measured. APPLICATIONS ¾Flow measurements. ¾ Ratio control coupled with pressure transmitters. ¾ Control of flow direction coupled with pressure switches. ¾ Control of combustion chamber pre-purge or burner ignition at minimum power (according to the EN746/2 Regulation). F5719I03 CHARACTERISTICS Primary measuring elements: ¾UNI PN16 Flanges: P245GH (ASTM A105) / AISI 304 ¾Ring chambers: Trivalent Galvanisation Fe360 - Fe430 - Fe510 / AISI 304 ¾Disc: AISI 304 ¾Maximum operating temperature: 500 C ¾Maximum operating pressure: 6 bar ¾Gaskets AFM-34 / X-PLUS Impulse lines (where present): ¾Pressure taps: OT58 ¾Fittings: nichel-plated brass / AISI 321 ¾Connection pipes (by customer) copper F5719I04 www.esapyronics.com 3

esa pt II COMBUSTIONE PER L'INDUSTRIA Patented - Brev. I 1268539 POP-U-S - E5719 rev. 06-26/06/14 DESCRIPTION The POP-U-S flanges are instantaneous flow measuring devices characterized by a primary element, made up of a recording device (calibrated diaphragm inserted in two ring chambers), and a secondary element generally made up of a MAG series differential pressure gauge (data sheet E5275) or of an ESA PT-II pressure transmitter (data sheet E7210). The POP-U-S calibrated flanges have welded connections (from DN20 and DN450) directly in the piping and the relative impulse lines are obtained in the flanges with ring chambers. These instruments are characterized by their simple installation, good precision and the possibility of being made in many different types of materials. The main versions that can be ordered are made to be used with the following fluids: ¾Air (room temperature or preheated) or inert fluids ¾Fuel gases belonging to classes 1/2/3 ¾Oxygen For other types of fluid, appropriate flanges can be supplied. In combustion plants the calibrated flanges represent the ideal instrument for measuring and controlling the flow of air and gas; the AIR/GAS ratio regulation in burners is in fact simpler when the precise volumes of combustion air and fuel gas are known. Together with the calibrated flanges, on request, MAG series differential pressure gauges with relative on-field mounting supports are available. For electronic ratio regulations ESA PT-II pressure transmitters are available. These allow to send (via 0 20mA or 4 20mA signal) the flow data detected to the remote equipment: temperature controllers, counters etc. F + - + - A A B B UPSTREAM PRESSURE "+" DOWNSTREAM "-" PRESSURE D5719I01 INFORMATION FOR SIZING To be able to correctly size the orifice hole inside the POP-WAC series calibrated flanges, the following project data available must be available: ¾ Fluid type ¾ Nominal pipe flow ¾ Differential pressure on calibrated flange ¾ Working pressure and temperature ¾ Nominal diameter of pipe (DN) ¾ Internal diameter of pipe (if not standard) www.esapyronics.com 4

IMPULSE LINE SOCKET KIT COMBUSTIBLE GAS IMPULSE LINE PREHEATED AND AMBIENT AIR IMPULSE LINE D5719I02 The calibrated flanges of the POP-U-S series are supplied with special preassembled impulse line socket kits, for which installation with measuring device must be done by the customer. This kit allows to connect the flange to the appropriate pressure transmitters that read the differential pressure between upstream and downstream the orifice. They give a precise indication of the fluid flow inside the pipe (according to the UNI EN5167-2 Norm).The kits are supplied according to the fluid inside the pipes. For oxygen use, the flanges always have a fitting fot copper tube ø 8mm. www.esapyronics.com 5

MINIMUM LENGTH OF THE STRAIGHT FITTINGS OF THE PIPING UPSTREAM AND DOWNSTREAM OF THE PRIMARY ELEMENT Table extracted from the ISO 5167-2: 2003 Standard. Note: Values expressed as multiples of internal diameter, D Diamete r ratio β Single 90 bend Two 90 bends in any plate (S > 30D) a Two 90 bends in the same plane: S- configurati -on (30D S > 10D) a Two 90 bends in the same plane: S- configurati -on (10D S) a Two 90 bends in perpendicu l-ar planes (30D S 5D) a Two 90 bends in perpendicular planes (5D > S) a,b Upstream (inlet) side of orifice plate Single 90 tee with or without an extension Mitre 90 bend Single 45 bend Two 45 bends in the same plane: S- configuratio -n (S 2D) a Concentric reducer 2D to D over a lenght of 1,5D to 3D Concentric expander 0,5D to D over a lenght of D to 2D Full bore ball valve or gate valve fully open abrupt symmetrical reduction Thermomet -er pocket or well c of diameter 0,03D d Downstrea -m (outlet) side of the orifice plate Fittings (columns 2 to 11) and the densitometer pocket 1 2 3 4 5 6 7 8 9 10 11 12 13 14 - A e B f A e B f A e B f A e B f A e B f A e B f A e B f A e B f A e B f A e B f A e B f A e B f A e B f 0,20 6 3 10 g 10 g 19 18 34 17 3 g 7 g 5 g 6 g 12 6 30 15 5 3 4 2 0,40 16 3 10 g 10 g 44 18 50 25 9 3 30 g 5 g 12 8 12 6 30 15 5 3 6 3 0,50 22 9 18 10 22 10 44 18 75 34 19 9 30 18 8 5 20 9 12 6 30 15 5 3 6 3 0,60 42 13 30 18 42 18 44 18 65 h 25 29 18 30 18 9 5 26 11 14 7 30 15 5 3 7 3,5 0,67 44 20 44 18 44 20 44 20 60 18 36 18 44 18 12 6 28 14 18 9 30 15 5 3 7 3,5 0,75 44 20 44 18 44 22 44 20 75 18 44 18 44 18 13 8 36 18 24 12 30 15 5 3 8 4 NOTE 1: The minimum straight lengths required are the length between various fittings located upstream or downstream of the orifice plate and the orifice plate itself. Straight length shall be measured from the downstream end of the curved portion of the nearest (or only) bend or of the tee or the downstream end of the curved or conical portion of the reducer of the expander. NOTE 2: Most of the bends on which the lengths in this table are based had a radius of curvatore equal to 1,5D. a: S is the separation between the two bends measured from the downstream end of the curved portion of the upstream bend to the upstream end of the curved portion of the downstream bend. b: This is not a good upstream installation: a flow conditioner should be used where possible. c: The installation of thermometer pockets of wells will not alter the required minimum upstream straight lengths for the other fittings. d: A thermometer pocket or well of diameter between 0,03D and 0,13D may be installed provided that the values in Columns A and B are increased to 20 and 10 respectively. Such an installation is not, however, recommended. e: Column A for each fitting gives lenghts corresponding to zero addirional uncertainty values (see 6.2.3). f: Column B for each fitting gives lenghts corresponding to 0,5% additional uncertainty values (see 6.2.4). g: The straight length in Column A gives zero additional uncertainty; data are not available for shorter straight lenghts which could be used to give the required straight lengths for Column B. h: 95D is required for Re D > 2 x 10 6 if S < 2D. www.esapyronics.com 6

FLOW SWITCH The new 2010 version of the EN746/2 Norm updated the part regarding the inspection to be carried out for the purging of the combustion chamber during furnace start-up and burner ignition with nominal power higher than 120kW, that must necessarily take place below 33% of the power. Following this update, it isn t sufficient to use a low air pressure switch on the pipe that ensures the correct blower ignition, but a differential pressure switch must be used (which in this case, becomes a minimum air flow switch) that can read the Dp of a calibrated flange and that gives permission to activate chamber purge as soon as the measured air flow exceeds 80% of the maximum nominal flow of the plant. In the same way, it is not possible to switch the burners on at minimum capacity relying on the servo motor limit switches, but a differential pressure switch is used (which in this case becomes a maximum air flow switch) that allows burner ignition below 33% of the nominal power of each. For the above mentioned applications, we suggest the use of a calibrated POP-U-S flange correctly connected to a pair of differential pressure switches according to the scheme in the figure. For this, a special pressure switch mounting kit may be supplied. 62 Nr.2 holes n 7 THE FLOW SWITCH ASSEMBLY MUST BE FIXED IN POSITION BY CLIENT, USING THE SPECIAL HOLES ON THE PLATE. D5719I03 FLOW SWITCH ASSEMBLY FOR ORIFICE FLOWMETER MOD. POP-U-S 2 3 4 1 UPSTREAM ORIFICE FLOWMETER PRESSURE INLET Copper pipe Ø8 (+) (-) FLOW OUTLET THE IMPULSE LINE ARE INCLUDED IN THE ORIFICE FLOWMETER ASSEMBLY DOWNSTREAM ORIFICE FLOWMETER PRESSURE INLET Copper pipe Ø8 FLOW INLET D5021I04 www.esapyronics.com 7

WARNINGS ¾Make sure that the fluid working pressure and temperature are below the maximum allowed limits. ¾The calibrated POP-U-S flanges are supplied with coupling flanges or gaskets. The flanges and gaskets are fit for the type of fluid and application. ¾Respect the diameters upstream and downstream according to the pipe sizes. ¾Any change or repair done by third parties may compromise the application safety and cause the general warrantee conditions to automatically expire. ¾Check the correct installation of the flange. INSTALLATION Maintenance and installation must be carried out by qualified staff, respecting the laws in force. After installation it is always advisable to carry out a tightness check on the threads or of the flange connections. 1 - For the mounting of the POP-U-S calibrated flange, follow the instructions printed on the actual flange. 2 - Check the correct alignment of the attachment pipes and maintain enough distance from the walls allowing air to circulate freely. 3 - Respect the upstream and downstream diameters according to the table. 4 - Make sure that no foreign bodies enter the valve body before assembling, if necessary blow with compressed air. 5 - Weld the flanges onto the ends of the pipes, eliminating any welding burrs. 6 - Place the gaskets with calibrated orifice in the correct direction. The printed symbol + must be placed upstream on the pipe with the orifice hole s 45 chamfer facing downstream the pipe. 7 - Using appropriate tools, progressively tighten crosswise. 8 - Avoid excessive tightening and mount without voltage. Do not install socket probes facing downwards to avoid possible obstruction of the fittings that could distort the readings. A ( 0.40 : 1 ) A D5021I05 www.esapyronics.com 8

GENERAL MAINTENANCE PLAN Operation Type Advised timing Notes Gasket integrity O annual Impulse socket integrity O annual Check that there are no leaks on the outside Check that there are no leaks on the outside O = Ordinary ORDINARY MAINTENANCE For correct maintenance of the POP-U-S organs, scrupulously follow the these instructions. Before carrying out manouvres with the plant on, make sure that the process safety and operator safety are not comprised. If necessary carry out inspection with plant off. INTEGRITY CHECK The integrity of the gaskets and threads can be checked visually. If necessary, use liquid leak detector. EXTRAORDINARY MAINTENANCE For correct maintenance of the POP-U-S orifices, scrupulously follow the instructions below that must be carried out with the plant off. BOLT TIGHTNENING 1 - The tightness must be checked with the plant off. GASKET REPLACEMENT 2 - Progressively unscrew the screws that hold the valve crosswise. Extract the orifice and replace the gasket. 3 - Clean the inside of the orifice with a clean cloth and compressed air. Do not use tools that could damage the internal parts. www.esapyronics.com 9

DIMENSIONS FLANGE POP-U-S-G (GAS) Impulse for copper pipe Ø8 "E" "D" Nr. "G" holes Ø"H" "B" "A" "F" "C" D5720I06 Model A DN PN ø B C D ±10 E F G ø H Screws 6 POP-U-S-G DN20 PN16 105 116 199 0 75 4 14 M12X90 3,5 8 POP-U-S-G DN25 PN16 115 116 205 0 85 4 14 M12X90 4 10 POP-U-S-G DN32 PN16 140 124 211 0 100 4 18 M16X100 6 12 POP-U-S-G DN40 PN16 150 134 224 0 110 4 18 M16X110 7,5 16 POP-U-S-G DN50 PN16 165 154 231 0 125 4 18 M16X120 9,5 20 POP-U-S-G DN65 PN16 185 163 234 0 145 4 18 M16X140 12,5 24 POP-U-S-G DN80 PN16 200 190 241 22,5 160 8 18 M16X150 16,5 32 POP-U-S-G DN100 PN16 220 194 252 22,5 180 8 18 M16X150 18,5 40 POP-U-S-G DN125 PN16 250 200 265 22,5 210 8 18 M16X150 23 48 POP-U-S-G DN150 PN16 285 200 278 22,5 240 8 22 M20X180 27,5 64 POP-U-S-G DN200 PN16 340 234 306 0 295 12 22 M20X180 42,5 80 POP-U-S-G DN250 PN16 405 252 334 0 355 12 26 M24X200 58 96 POP-U-S-G DN300 PN16 460 288 362 0 410 12 26 M24X220 77 112 POP-U-S-G DN350 PN16 520 316 392 11,25 470 16 26 M24X240 132,5 128 POP-U-S-G DN400 PN16 580 324 417 11,25 525 16 30 M27X260 148,5 144 POP-U-S-G DN450 PN16 640 328 447 0 585 20 30 M27X270 191 Mass [Kg] Welding flanges according to UNI2282-67 PN16. www.esapyronics.com 10

DIMENSIONS FLANGE POP-U-S-A (AIR) IMPULSE FOR COPPER PIPE Ø8 "E" Nr."G" holes Ø"H" "D" "B" "A" "F" "C" D5720I06 Model A DN PN ø B C D ±10 E F G ø H Screws 6 POP-U-S-A DN20 PN16 105 116 150 0 75 4 14 M12X90 3 8 POP-U-S-A DN25 PN16 115 116 154 0 85 4 14 M12X90 4 10 POP-U-S-A DN32 PN16 140 124 168 0 100 4 18 M16X100 5,5 12 POP-U-S-A DN40 PN16 150 134 173 0 110 4 18 M16X110 7 16 POP-U-S-A DN50 PN16 165 154 181 0 125 4 18 M16X120 9 20 POP-U-S-A DN65 PN16 185 163 184 0 145 4 18 M16X140 12 24 POP-U-S-A DN80 PN16 200 190 191 22,5 160 8 18 M16X150 16 32 POP-U-S-A DN100 PN16 220 194 202 22,5 180 8 18 M16X150 18 40 POP-U-S-A DN125 PN16 250 200 216 22,5 210 8 18 M16X150 22,5 48 POP-U-S-A DN150 PN16 285 200 228 22,5 240 8 22 M20X180 27 64 POP-U-S-A DN200 PN16 340 234 256 0 295 12 22 M20X180 42 80 POP-U-S-A DN250 PN16 405 252 284 0 355 12 26 M24X200 57,5 96 POP-U-S-A DN300 PN16 460 288 311 0 410 12 26 M24X220 76,5 112 POP-U-S-A DN350 PN16 520 316 342 11,25 470 16 26 M24X240 132 128 POP-U-S-A DN400 PN16 580 324 367 11,25 525 16 30 M27X260 148 144 POP-U-S-A DN450 PN16 640 328 397 0 585 20 30 M27X270 191 Mass [Kg] Welding flanges according to UNI2282-67 PN16. www.esapyronics.com 11

DIMENSIONS FLANGE POP-U-S-O (OXYGEN) IMPULSE FOR COPPER PIPE Ø8 "E" Nr."G" holes Ø"H" "F" "B" "A" "D" "C" D5720I06 Model A DN PN ø B Welding flanges according to UNI2282-67 PN16. C D ±10 E F G ø H Screws 6 POP-U-S-O DN20 PN16 105 116 52,5 0 75 4 14 M12X90 3 8 POP-U-S-O DN25 PN16 115 116 57,5 0 85 4 14 M12X90 3,5 10 POP-U-S-O DN32 PN16 140 124 63 0 100 4 18 M16X100 5,5 12 POP-U-S-O DN40 PN16 150 134 68 0 110 4 18 M16X110 6,5 16 POP-U-S-O DN50 PN16 165 154 75,5 0 125 4 18 M16X120 8,5 20 POP-U-S-O DN65 PN16 185 163 90,5 0 145 4 18 M16X140 12 24 POP-U-S-O DN80 PN16 200 190 98 22,5 160 8 18 M16X150 16 32 POP-U-S-O DN100 PN16 220 194 108 22,5 180 8 18 M16X150 18 40 POP-U-S-O DN125 PN16 250 200 122 22,5 210 8 18 M16X150 22 48 POP-U-S-O DN150 PN16 285 200 135 22,5 240 8 22 M20X180 27 64 POP-U-S-O DN200 PN16 340 234 162,5 0 295 12 22 M20X180 42 80 POP-U-S-O DN250 PN16 405 252 190,5 0 355 12 26 M24X200 57 96 POP-U-S-O DN300 PN16 460 288 218 0 410 12 26 M24X220 76 112 POP-U-S-O DN350 PN16 520 316 248 11,25 470 16 26 M24X240 132 128 POP-U-S-O DN400 PN16 580 324 273,5 11,25 525 16 30 M27X260 147,5 144 POP-U-S-O DN450 PN16 640 328 303,5 0 585 20 30 M27X270 190,5 Mass [Kg] www.esapyronics.com 12

ORDERING CODE - CALIBRATED ORIFICE ONLY - POP - U - S - 01 02 MODEL 01 02 FLUID 6 8 10 64 80 128 144... 6 8 10 64 80 128 144... Gas Air Oxygen Special Gas G A O SG see tab. pag. 10/11/12 Including: - Calibrated orifice - Welding flanges according to EN1092-1 - Impulse kit for pressure transmitter or differential pressure gauge. The materials will be suitable for the type of fluid used in the pipes. ORDERING CODE - CALIBRATED ORIFICE ONLY - OP - U - S - 01 02 MODEL 01 02 FLUID 6 8 10 64 80 128 144... 6 8 10 64 80 128 144... Gas Air Oxygen Special Gas G A O SG see tab. pag. 10/11/12 www.esapyronics.com 13