Model 601CV. Mass Flow Controller. Product Features:

Similar documents
Porter Analytical & Industrial Products

CORI-FLOW PRECISION MASS FLOW METER / CONTROLLER FOR LIQUIDS AND GASES

Porter Lab & Analytical Products

IN-FLOW CTA Industrial Mass Flow Meters and Controllers for Gases

Features. Main Voltage: Vdc. Input Control Signal: 0-5 Vdc or 4-20 madc (Sourcing) Monitor Output Voltage: 0-5 Vdc or 4-20 madc (Sourcing)

Digital Mass Flow Meters and Controllers for Gases

X-Flow Mass Flow Controller 授权代理 : 北京品超思瑞科技学院公司

Precision Mass Flow Meters / Controllers for Liquids and Gases

Design Features. General Description

Analogue and Digital Mass Flow Meters and Controllers for Gases MASS-STREAM

Brooks TMF-Zone 1 Models 5816-Ex/5864-Ex

Mass Flow Controller (MFC) for Gases

GFM. Typical Aluminum GFM Mass Flow Meter NIST MASS FLOW METERS. Principles of Operation. Design Features

AFC. SDPROC and AFC Analog Mass Flow Controller ANALOG MASS FLOW CONTROLLERS. Principles of Operation. Design Features

Mass Flow Controller (MFC) for Gases

Mass Flow Controllers

Mass Flow Meter (MFM) for gases

Bypass Mass Flow Controller (MFC) for gases

Liquids and Gases Gas & Liquid

SCOPE OF THIS GUIDE STARTING-UP. 1 Check mini CORI-FLOW functional properties

Mass Flow Controller (MFC) for Gases

TELEDYNE HASTINGS INSTRUMENTS PRELIMINARY BULLETIN. Models HFM-D-301 & 305, HFC-D-303 & 307

Quick Installation Guide Doc nr.: C Date:

780S Ultra High Purity Series

Technical Data Sheet High Performance Digital Gas Mass Flow Meters and Controllers Features Description

MASS-STREAM TM Instruction Manual. D-6200 Analog Mass Flow Meters / Controllers

ATM/GR. Electronic pressure switches CUSTOMER BENEFITS

Modular Gas System. Modular Gas Delivery Stick Components for Microelectronics Equipment Gas Boxes

Mass Flow Controller (MFC) for Gases

Mass Flow Meter (MFM) for Gases

Mass Flow Controller (MFC) for Gases

The intelligent alternative for VA meters: mass flow meters for gases with flow display

Mass Flow Controller (MFC) for Gases

EPR High Precision 3000 psi Electronic Pressure Controller Accurate to 0.25% of full scale

Max-Trak Model 180. Technical Data Sheet. NEMA 6 / IP67 Compliant Industrial Mass Flow Meters and Controllers For Gases

Parametrable / Programmable Pressure Transmitter

Programmable pressure and temperature transmitters PTM/RS485

Mass Flow Controller (MFC) for gases. Inline MFC for nominal flow rates from 25 I N. /min to I N

High Performance Digital Gas Mass Flow Meters & Controllers

BUBBLER CONTROL SYSTEM

BUBBLER CONTROL SYSTEM

SmartTrak 100HP. Ultra-High Pressure Digital Gas Mass Flow Meters & Controllers. FEATURES DESCRIPTION

TH-1800-T TRX-700-CNG Converter

Technical Data for Alicat MS Series Mass Flow Meters

TKF Mass Flow Controller. FCS Thermal Series. Digital interface 준비장비 (RS-485)

SmartTrak. High Performance Digital Gas Mass Flow Meters & Controllers. DESCRIPTION

MCQ Gas Blender 100 Series 3 Channels Gas Mixer

MANUAL KPS Pressure Control Valve

Programmable pressure and temperature transmitters PTM/RS485

Liquids and Gases Gas & Liquid

2600T Series Pressure Transmitter Models 264DC Differential and 264HC Gage Level Transmitters. Kent-Taylor

Ultra High Purity Model 780S

MASS FLOW SYSTEMS MASS FLOW MEASURING, CONTROLLING AND BLENDING SYSTEMS

TEK-THERMAL 1700B. Thermal Mass Flowmeter. FLOW. Technology Solutions

Miniature Electronic Pressure Controllers. Precision Fluidics

Operating Instructions for Direct Flow Mass Flow Meter for gases. Model: DMW

NT High-temperature flowmeter model Simultaneous flow and pressure outputs for high-temperature applications

Flow Meters and Flow Controllers

Programmable Submersible Level Transmitters

SideTrak 830/840. Process Gas Mass Flow Meters and Controllers. FEATURES DESCRIPTION

Instruction and Maintenance Manual

AMS 2710 PCB pressure sensor module with V output

C-Flow Coriolis Mass Flow Meters

analytical bulk flow distance FLOW level pressure temperature industrial communication

3.0 Pressure Transmitter Selection

SX150A. Features. Typical Applications. Description

Features. Description

HumiSys HF High Flow RH Generator

COSMO INSTRUMENTS CO., LTD.

UNDERSTANDING, ACCELERATED

ATM.ECO - Analog Pressure Transmitter

AMS 6916 Board mount pressure sensor with ratiometric analog output

800 Series Mass Flow Meters and Controllers. High Performance Mass Flow Meters and Controllers

SLA5810/20/40 SLAMf10/20 Series

MACH ONE MASS FLOW CONTROLLER. MACH ONE SERIES flow control. MASS FLOW CONTROLLERS at the speed of sound.

The M-Series Eletta Flow Meter High accuracy DP Flow Meter with multiple functions

ATM - Analog Pressure Transmitter

Over 20,000 Strain Gage Target flowmeters installed since 1952.

Industrial Hydraulic Valves. Directional Control, Pressure Control, Sandwich, Subplates & Manifolds, Accessories. Catalog HY /US

Visualize Nitrogen Gas Consumption

red-y compact series product information Battery Powered Thermal Mass Flow Meters for Gases

Instruction manual. General instructions digital Mass Flow / Pressure instruments laboratory style / IN-FLOW. Doc. no.: Y Date:

BAROMETER PRESSURE STANDARD PRESSURE CONTROLLER

EPP4 Pressure Regulator Basic G 1/4"

INSTRUCTION MANUAL. process. Ultrasonic Flowmeter Range

BD Series Back Pressure Regulators and Valves For Gas, liquid and mixed phase service

Flow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25

Flow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25

PS100 Series. Pressure-Based PI Mass Flow Controller. Catalog

High-speed pressure sensor Model CPT6140

Instruction and Maintenance Manual

Operating Instructions DB41

Flow metering in gases Introduction to COMBIMASS family

AMS 6915 Board mount pressure sensor with digital output (I²C)

Precision pressure sensor Basic version Model CPT6020

INSTALLATION & MAINTENANCE INSTRUCTIONS

MASFLO-OVAL Ⅱ THERMAL MASS FLOWMETER/CONTROL VALVE for GAS MEASUREMENT MODEL: FHC, FHD series

ASDX Series Silicon Pressure Sensors

INSTRUMENTS A THERMAL MASS FLOW SENSOR USING A CONSTANT DIFFERENTIAL TEMPERATURE ABOVE THE AMBIENT GAS TEMPERATURE

Pneumatic spool valve islands

Transcription:

Model 601CV Mass Flow Controller Porter s Model 601CV Series II Mass Flow Controller (MFCs) is designed for precise control of virtually all conventional process gases. The MFC consists of a thermal mass flow sensor, a precise control valve and a microprocessor based PID controller with signal and fieldbus conversion. Based on the setpoint input value, the flow controller swiftly adjusts to the desired flow rate. The mass flow rate is provided as analog signal or digitally via RS232 or various fieldbus options. Each unit is specifically sized and calibrated depending on the types of gas and the process conditions of the application. Product Features: Full Scale Flow Ranges from 8 ml/min to 25 l/m Operating Pressures up to 928 PSIA High accuracy and repeatability Storage of max. 8 calibration curbes User configurable control characteristics Flow Parameter Adjust functionality up to 150 PSIA Effective Rangeability <180:1 Analog or digital: RS232, DeviceNet, ProfibusDP, Modbus-RTU

500/600 Series II Flowmeter Products Thermal Mass Flow Measuring Principle The Mass Flow Sensing System consists of a stainless steel capillary tube with two precision heater and temperature sensing elements wound around the outside of the tube. As gas flows through the capilliary tube, heat is displaced to the downstream temperature sensor creating a differential between the two sensors. The difference is directly proportional to mass flow through the tube. In the main flow channel, a patented laminar flow element package creates a restriction that forces a fixed percentage of the total flow through the sensor for temperature differential detection. Medium temperature Flow Turbulence filter Measured ΔT Heater 1 and Temperature measurement 1 Heater 2 and Temperature measurement 2 Laminar flow element Temperature profile without flow Temperature profile with flow Ambient temperature Sensor tube ΔT = k.c p.ø m ΔT = T2-T1 in Kelvin C p = specific heat Ø m = mass flow State of the Art Digital Design Porter s Series II Mass Flow products are equipped with a microprocessor based digital pc-board offering high accuracy, excellent temperature stability and fast MFC response time. The basic digital pc-board contains all of the general functions needed for measurement and control. RS232 communication and analog I/O are included. An optional integrated communication interface board provides DeviceNet, Profibus-DP or Modbus-RTU. Models and Flow Ranges Model Minimum Nominal Maximum Model Minimum Nominal Maximum 601CV-D 0.16 to 8 ml/min 0.16 to 20 ml/min 0.16 to 30 ml/min 601CV-I 8 to 400 ml/min 8 to 1000 ml/min 8 to 1500 ml/min 601CV-E 0.4 to 20 ml/min 0.4 to 50 ml/min 0.4 to 75 ml/min 601CV-J 16 to 800 ml/min 16 to 2000 ml/min 16 to 3000 ml/min 601CV-F 0.8 to 40 ml/min 0.8 to 100 ml/min 0.8 to 150 ml/min 601CV-K 0.04 to 2 l/min 0.04 to 5 l/min 0.04 to 7.5 l/min 601CV-G 1.6 to 80 ml/min 1.6 to 200 ml/min 1.6 to 300 ml/min 601CV-M 0.08 to 4 l/min 0.08 to 10 l/min 0.08 to 15 l/min 601CV-H 4 to 200 ml/min 4 to 500 ml/min 4 to 750 ml/min 601CV-N 0.16 to 8 l/min 0.16 to 20 l/min 0.16 to 25 l/min All flow ranges are at standard conditions of 14.7 PSIA and 70 F (21.1 C)

Specifications Measurement / Control System Accuracy (incl. linearity) (based on actual calibration) Standard: ±0.5% Reading plus ±0.1% Full Scale (±1% Full Scale for ranges 3-5 ml/min; ±2% Full Scale for ranges < 3 ml/min) Turndown 1 : 50 (in digital mode up to 1 : 187.5) Repeatability Settling Time (Controller) <0.2% Reading Standard: 1-2 seconds Control Stability <±0.1% Full Scale (typical for 1 l/min N 2 ) Operating Temperature Temperature Sensitivity -10 to +70 C Zero: <0.05% Full Scale/ C; span: <0.05% Reading/ C Pressure Sensitivity 0.1%/ATM typical N2; 0.01%/ATM typical H 2 Leak Integrity, outboard Tested < 2 x 10-9 mbar l/s He Attitude Sensitivity Max. error at 90 off horizontal 0.2% at 1 ATM, typical N 2 Warm-Up Time 30 min. for optimum accuracy 2 min. for accuracy ±2% Full Scale Mechanical Parts Material (wetted parts) Surface Quality (wetted parts) Process Connections Seals Ingress Protection (housing) Electrical Properties Power Supply Power Consumption Analog Output/Command Digital Communication Electrical Connection Analog/RS232 Profibus-DP DeviceNet EtherCAT Modbus-RTU/FLOW-BUS Stainless steel 316L or equivalent Ra= 0.8µm typical Compression or face seal fittings Standard: Viton Options: EPDM, Kalrez (FFKM) IP40 +15-24 Vdc Meter: 70 ma; Controller: max. 320 ma; Add 50 ma for Profibus, if applicable 0-5 (10) Vdc or 0 (4)-20 ma - specify - (Sourcing output) Standard: RS232 Options: Profibus-DP, DeviceNet, EtherCAT, Modbus 9-pin D-connector (male) Bus: 9-pin D-connector (female) Power: 9-pin D-connector (male) 5-pin M12-connector (male) 2 x RJ45 modular jack (in/out) RJ45 modular jack Technical specifications and dimensions subject to change without notice.

Dimensions Brackets = Millimeters 1/4 BSPP Compression Size A Fitting 3 mm OD 1.028 (26.1) Fitting 6 mm OD 1.118 (28.4) Fitting 8 mm OD 1.157 (29.4) Fitting 10 mm OD 1.189 (30.2) Fitting 12 mm OD 1.280 (32.5) Fitting 1/8 OD 1.028 (26.1) Fitting 1/4 OD 1.118 (28.4) Fitting 3/8 OD 1.177 (29.9) Fitting 1/2 OD 1.287 (32.7) Face-Seal Male Size A Fitting 1/4 inlet 0.913 (23.2) (Millimeters) Ordering Information 6 0 1CV C A A D 1 1 V Model 6 Controller Pressure Rating 0 928 PSIA Flow Ranges 1CV 0 to 8 / 0 to 25 l/min (906, 1.5K PSIA) Nominal Range Factory Selected Communication (I/O) A RS232 + Analog, N.C. Valve B RS232 + Analog, N.O. Valve D RS232 + DeviceNet, N.C Valve E RS232 + DeviceNet, N.O. Valve M RS232 + Modbus-RTU, N.C. Valve N RS232 + Modbus-RTU, N.O. Valve P RS232 + Profibus -DP, N.C. Valve Q RS232 + Profibus - DP, N.O. Valve R RS232 + FLOW-BUS, N.C. Valve S RS232 + FLOW-BUS, N.O. Valve Elastomers V Viton (Factory Standard) E EPDM K Kalrez (FFKM) Connections (in/out) 1 1/8 OD Compression 2 1/4 OD Compression 3 6 mm OD Compression 8 1/4 Face Seal Male 9 Other 0 None Supply Voltage D +15 to 24 Vdc Analog I/O A 0 to 5 Vdc B 0 to 10 Vdc F 0 to 20 ma Sourcing G 4 to 20 ma Sourcing

Hook-up Diagram for Analog or RS232 Communication Note: Pin 4 and Pin 8 should be seperatly and connected to power common at the power supply. Note: When using a unit configured for a fieldbus or RS232 I/O, it is not possible to operate the instrument using analog I/O without changing the control mode parameter. (See users manual) Note: For hookup details of modbus, Profibus or DeviceNet communications, see users manual. Note: Do not connect external valve to instruments configured as flow meters Note: Valve out signal is 0-10 Vdc,.1mA WARNING USER RESPONSIBILITY FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY DAMAGE. This document and other information from Parker-Hannifin Corporation, its subsidiaries and authorized distributors provide product or system options for further investigation by users having technical expertise. The user, through its own analysis and testing, is solely responsible for making the final selection of the system and components and assuring that all performance, endurance, maintenance, safety and warning requirements of the application are met. The user must analyze all aspects of the application, follow applicable industry standards, and follow the information concerning the product in the current product catalog and in any other materials provided from Parker or its subsidiaries or authorized distributors. To the extent that Parker or its subsidiaries or authorized distributors provide component or system options based upon data or specifications provided by the user, the user is responsible for determining that such data and specifications are suitable and sufficient for all applications and reasonably foreseeable uses of the components or systems. Offer of Sale The items described in this document are hereby offered for sale by Parker-Hannifin Corporation, its subsidiaries or its authorized distributors. This offer and its acceptance are governed by the provisions stated in the detailed Offer of Sale elsewhere in this document or available at www.parker.com/offerofsale. WS-0030 Rev. D 10/13 Parker Hannifin Corporation Porter Instrument Division 245 Township Line Road Hatfield, PA 19440 phone 215 723 4000 fax 215 723 2199 industrial@parker.com www.parker.com/porter