Dosimetric Calculations. Lonny Trestrail

Similar documents
1. Question Answer cgy / MU cgy / MU 2. Question Answer

Relative Dosimetry. Photons

Math Review. Overview

Review of fundamental photon dosimetry quantities

Monitor Unit Calculations Part 2. Calculation of machine setting. Collimator setting

Outline. Chapter 11 Treatment Planning Single Beams. Patient dose calculation. Patient dose calculation. Effect of the curved contour surface

Monitor Unit Calculations Part 1. Return to our first patient. Purpose. 62 yr old woman with Stage IIIB (T1N3M0) NSCLC rt lower lobe Dose prescription

13 QUALITY ASSURANCE OF A LINEAR ACCELERATOR 13.1 COLLIMATOR ISOCENTER, JAWS, LIGHT FIELD VS INDICATORS, COLLIMATOR ANGLE INDICATORS.

Monitor Unit Verification for Small Fields

Field size and depth dependence of wedge factor for internal wedge of dual energy linear accelerator

JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, VOLUME 3, NUMBER 4, FALL 2002

3D Treatment Planning and verification with hand calculations

Commissioning an IMRT System for MLC Delivery. Gary A. Ezzell., Ph.D. Mayo Clinic Scottsdale

The Royal Australian and New Zealand College of Radiologists. FRANZCR Examination Part I Radiation Oncology. Radiotherapeutic Physics.

Commissioning and quality assurance of a commercial intensity modulated radiotherapy (IMRT) treatment planning system PrecisePLAN

Radiotherapy physics & Equipments

Planning Assignment (3 field rectum)

Zoubir Ouhib Lynn Cancer Institute

CHAPTER-2. Wedge filters are the most important beam modifiers used in

High Speed Direct SAD Radiosurgery Beam Scanner

Scientific Journal of Nuclear Medicine & Radiation Therapy

The MC commissioning of CyberKnife with MLC (Tips and Tricks)

Clinical Implementation of the TG-51 Protocol. David Followill Radiological Physics Center Houston Texas

THE development of more advanced techniques in radiotherapy,

Commissioning of a new total body irradiation protocol

Treatment Planning Techniques for Larger Body Habitus Patients for Breast/Chestwall and Regional Lymph Nodal Irradiation

CHAPTER 4 PRE TREATMENT PATIENT SPECIFIC QUALITY ASSURANCE OF RAPIDARC PLANS

WEDGE FILTERS FOR MEGAVOLTAGE ROENTGEN RAY BEAMS

OUTPUT at dmax in tissue 8x8 20x20 At 100cm SSD At 100cm SAD

SnapShot IMRT with compensators and FFF beams

The dose distribution of medium energy electron boosts to the laryngectomy stoma

IMRT in clinical practice at the UMC-Utrecht. Utrecht

Constancy checks of well-type ionization chambers with external-beam radiation units

Only 8% to go. TOTAL 1494 of 1623 ACTIVE INSTITUTIONS (92%) May-09. May-04 Nov-04. May-07. Nov-02 May-03. Nov-05. Nov-06. Nov-07 May-08.

TG219: IT'S USE, STRENGTHS AND WEAKNESSES

Clinical Implementation of Volumetric Modulated Arc Therapy

TG-119 IMRT Commissioning Tests Instructions for Planning, Measurement, and Analysis Version 10/21/2009

CLINICAL IMPLEMENTATION OF RAPIDARC Treatment Planning Strategies to Improve Dose Distributions

A beam-matching concept for medical linear accelerators

Iranian Journal of Medical Physics

Investigation of Buildup Dose for Therapeutic Intensity Modulated Photon Beams in Radiation Therapy

Commissioning and periodic tests of the Esteya electronic brachytherapy system

ANALYSIS OF OFF-AXIS ENHANCDED DYNAMIC WEDGE DOSIMETRY USING A 2D DIODE ARRAY A CREATIVE PROJECT (3 SEMESTER HOURS) SUBMITTED TO THE GRADUATE SCHOOL

A dose delivery verification method for conventional and intensitymodulated radiation therapy using measured field fluence distributions

Introduction. Introduction. The CyberKnife SRS/SBRT System. Introduction. Contour Structures. CyberKnife Components

A simple theoretical verification of monitor unit calculation for intensity modulated beams using dynamic mini-multileaf collimation

TEST REPORT BEAMSCAN WITH HALCYON

Absorption measurements for a carbon fiber couch top and its modelling in a treatment planning system

Commissioning of Elekta 6MV FFF Versa HD and Pinnacle

Practical Course in Reference Dosimetry, National Physical Laboratory February 2014 MV Photon Dosimetry in the Clinic Page 1 of 11

Clinical Implementation of the IPEM 2003 Code of Practice for Electron Dosimetry

GEANT4 SIMULATION OF AN ACCELERATOR HEAD FOR INTENSITY MODULATED RADIOTHERAPY

The Effect of Immobilisation Devices on Radiotherapy Dose Distributions. Alison Gray August 2007

Validation of Treatment Planning Dose Calculations: Experience Working with Medical Physics Practice Guideline 5.a.

A clinical comparison and analysis between conventional MLC based and solid compensator based IMRT treatment techniques

TG-61 deals with: This part of the refresher course: Phantoms. Chambers. Practical Implementation of TG-61:

1. BEAM MODIFIERS IN RADIOTHERAPY

AAPM s TG-51 protocol for clinical reference dosimetry of high-energy photon and electron beams

Development of Graphical User Interfaces (GUI) software and database for radiation therapy applications

RADIOLOGY/ FLUOROSCOPY 15 RAD-CHECK PLUS X-RAY EXPOSURE METER

Experimental verification of a Monte Carlo-based MLC simulation model for IMRT dose calculations in heterogeneous media

Exradin Ion Chambers. What attributes make Exradin the smart choice? EXRADIN Ion Chambers

Evaluation of six TPS algorithms in computing entrance and exit doses

Basics of Proton Therapy. Proton Treatment Planning and Beam Optimization

Comparison of ionization chambers of various volumes for IMRT absolute dose verification

COMPASS. Dr. Lutz Müller. AK IMRT Bamberg April D IMRT Verification in Patient Anatomy

Dynamic wedges dosimetry and quality control

Anemometry. Anemometry. Wind Conventions and Characteristics. Anemometry. Wind Variability. Anemometry. Function of an anemometer:

USER MANUAL PROGRAM VERSION 1.0.1

Breast Treatment System REFERENCE MANUAL

Implementation of respiratory-gated VMAT on a Versa HD linear accelerator

Digiquartz Water-Balanced Pressure Sensors for AUV, ROV, and other Moving Underwater Applications

TG-51: Experience from 150 institutions, common errors, and helpful hints

Abstract: Introduction:

METROLOGY LAB. I DEVICES BASED ON VERNIER SCALE

Aerodynamic Terms. Angle of attack is the angle between the relative wind and the wing chord line. [Figure 2-2] Leading edge. Upper camber.

COMPARISON BETWEEN PHYSICAL WEDGES AND VIRTUAL WEDGES IN LINAC

Larry A. DeWerd, Ph.D., FAAPM UW ADCL & Dept. of Medical Physics University of Wisconsin

Chapter 15 Wave Motion. Copyright 2009 Pearson Education, Inc.

Beam modeling and VMAT performance with the Agility 160-leaf multileaf collimator

Regional Workshop on the International Basic Safety Standards. Session 10: Emergency Preparedness and Response

VariSource High Dose Rate Afterloader Procedures. For Performing Breast Brachytherapy with. The SAVI TM Applicator

Surface buildup dose dependence on photon field delivery technique for IMRT

7.65 ±0.05 mm of lead. The maximum energy of the bremsstrahlung photons was calibrated using the threshold for the D(-y,n)H reaction at

Physics and Quality Assurance

Underwater measurement of photosynthetically active radiation

Exposure System Selection

S0300-A6-MAN-010 CHAPTER 2 STABILITY

DEFINITIONS. Aerofoil

Radiation Producing Machines Radiation Safety Training for X-ray Diffraction Units

The field of play must be rectangular and marked with lines. These lines belong to the areas of which they are boundaries.

Properties of waves. Definition:

The Discussion of this exercise covers the following points:

AN EXPERIMENTAL STUDY OF THE EFFECTS OF SWEPT ANGLE ON THE BOUNDARY LAYER OF THE 2D WING

Computationally Efficient Determination of Long Term Extreme Out-of-Plane Loads for Offshore Turbines

Sesam HydroD Tutorial

Lab 7 Rotational Equilibrium - Torques

MIT Analytical X-Ray Safety Policies and Procedures

AN31E Application Note

Slide 2 / 28 Wave Motion. A wave travels along its medium, but the individual particles just move up and down.

Transcription:

Dosimetric Calculations Lonny Trestrail 20 October 2008

Objectives Dose Distribution Measurements PDD, OCR TAR, SAR, TPR, TMR, SPR, SMR Arc or Rotational Therapy Isodose Curves Point Dose Calculations Wedged Fields Photon Beam Models 2

Definition of Tumor Volumes 3

Definition of Terms ( F ) SSD Source Skin Distance ( Fm ) SAD Source Axis Distance 4

Definition of Terms CAX Central Axis Isocenter 5

Percentage Depth Dose %D n = D n / D 0 x 100% Varies w/depth Beam Energy Depth Field Size Source Distance Collimation 10x10, dmax 6

%DD vs. Photon Beam Energy 7

%DD Tables 8

MDE Conventional PDD Tables 9

MDE Convolution PDD Tables 10

Sterling's Rule Effective Field Size This rule states that a rectangular field is equivalent to a square field if bot h ( A/P ) have the same ratio of area/perimeter Example 15x8 has an A/P of 2.61 ( 2.58 ) ~2.61 of 10.3x10.3 has an A/P 4 A/P = 10.4 11

Transverse Profile 12

TAR Used in Calculating Arc Rotations Use average TAR, not average depth 13

TAR Measurement 14

Tissue Air Ratio (TAR) TAR = D d / D air Where: D d : dose to a small volume of tissue in a medium D air : dose to a small volume of tissue in air Depends on: Energy, Depth, Field Size Accounts for tissue attenuation Used for isocenter treatments and rotational treatments 15

( SAR ) Scatter-Air Ratio ( fs SAR = TAR(finite fs) TAR(zero Depends on: Energy, Depth, Field Size Useful in do s e computation of irregularly shaped fields 0x0 fs: hypothetical field rep 16

Irregularly Shaped Fields Clarkson's integration Separates primary and secondary Primary contribution Zero area TAR Secondary contribution Sum of irregularly shaped scatter contribution 17

Clarkson's Irregular Field Calculation 18

( TPR ) Tissue/Phantom Ratio TPR = D d / D ref Where: D d : dose to a point in phantom D ref : dose at the same point at a fixed ref depth Depends on: Energy, Depth, Field Size 19

TPR Measurement If t 0 is the ref depth of max dose, then: TMR(d, r d ) = TPR(d, r d ) 20

( TMR ) Tissue Maximum Ratio TMR = D d / D refmax Where: D d : dose to a point in phantom D refmax : dose at the same point at maxref depth Depends on: Energy, Depth, Field Size 21

( SPR ) Scatter/Phantom Ratio Ratio of the dose contribution solely by scattered radiation at a given point divided by the reference dose at a selected depth in the phantom 22

( SMR ) Scatter-Maximum Ratio Ratio of the dose caused solely by scattered radiation at a given point divided by the maximum dose measured at the same distance from the radiation source 23

Isodose Curves Lines passing thru points of equal dose Percentage of the dose at a reference point Dose distribution off axis CAX depth dose distribution is not sufficient to characterize a radiation beam that produces a dose distribution in a threedimensional volume. 24

Isodose Curves SSD normalized at dmax ( isocenter ) SSD normalized at depth 25

Isodose Curves Perpendicular to CAX 26

Point Dose Calculations Treatment unit calibration ( cm Calibrated at defined SSD (100 dmax, 5, 10 cm deep Calibrated at isocenter dmax, 5, 10 cm deep MU calculation depends upon calibration Meter Setting (MU) = Prescribed dose related to calibration conditions Calibration dose rate 27

Treatment at Standard SSD MU = Given Dose / Dose Rate at dmax Given dose: (Rx'd dose @ depth)*100 / (%Dn) = Dose at dmax Dose rate at dmax: Dm = Dc Sc Sp F Dc: calibrated dose rat e ( cgy/mu at dm for 10x10 cm field size, or (1 Sc: collimator s c atter factor normalized to 10x10 cm field size 28

Treatment at Isocenter Meter setting (MU) = Prescribed dose at isocenter Dose rate at isocenter Meter setting (MU) = Prescribed dose at isocenter Dc [(SSD+dMax)/SAD] 2 TMR Sc Sp F 29

Distribution of Multiple Fields Parallel opposed fields CAX CAX depth dose opposed fields vs. energy Equal weighted or unequal weighted beams Minimum dose in mid-plane Build up at entrance of both fields Often normalized to 100% or dose to a point (tumor) in the patient 30

CAX Depth Dose vs. Energy 31

Parallel Opposed Beams 32

Example Problem A patient is to be treated using a AP/PA pair of fields and a SSD technique. The patient is 22 cm thick. The field size is 10x15 cm with minimal blocking, however a block tray is used. The physician prescribes 61.2 Gy at 1.8 Gy/ treatment to the 90% isodose line. The fields are equally weighted at dmax from each field. How many MU s are needed/ day for each field? 33

Example Problem A patient is to be treated using a AP/PA pair of fields and a SSD technique. The patient is 22 cm thick. The field size is 10x15 cm with minimal blocking, however a block tray is used. The physician prescribes 61.2 Gy at 1.8 Gy/ treatment to the 90% isodose line. The fields are equally weighted at dmax from each field. How many MU s are needed/ day for each field? 34

Answer MU = Prescribed Dose / Field / Day %DD*100*TF*ROF MU = 180 cgy / 2 / 0.9 ( d11)*tf*rof(12 %DD(12x12 @ MU = 100 0.6475 * 0.97 * 1.016 MU = 157 MU 35

External Beam Plan 36

Answer MU = Prescribed Dose / Field / Day %DD*100*TF*ROF MU = 180 cgy / 0.9 / 2 / 1 ( d11)*tf*rof(12 %DD(12x12 @ MU = 100 0.65296 * 0.966 * 1.016 MU = 156 MU 37

MDE PDD 0.65296 38

MDE Tray Factor 0.966 39

MDE Output Factor 1.016 40

Plan Summary 142 vs 156 Rx Isodose dmax Field Size Effective Square Fast Photon 143 vs 156 Scatter 41

The Wedged Beam Metal wedge shaped filter is put in beam to tilt isodose curve Angle usually defined at d10, or 50% isodose Types of wedge filters Solid metal Universal Dynamic wedge Isodose curves change with field size Flatness changes with depth 42

Isodose Curve of Wedged Beam 43

Wedged vs. Unwedged Fields 44

45

46

Typical Head & Neck Plan 47

Photon Inhomogeneity Correction Density affects attenuation of x-rays Lung with a density of 0.25-0.30 attenuates much less than normal tissue Bone with a higher density and atomic number attenuations x-rays more Inhomogeneities also affect scatter Lung corrections 10-15% for 5-8 cm lung tissue 48

Photon Beam Models Analytical method: %DD x OAR Matrix Technique: Fan lines and %DD Semi-Empirical Methods Clarkson Integration Differential Scatter Air Ratio Heterogeneity Corrections Co n v ( Kernels ) olution Superposition Algorithm 49