Air-Fuel Ratio Measurement using Ceramic Sensors

Similar documents
Technical Data Sheet MF010-O-LC

Protective Atmospheres, Measurement Technologies and Troubleshooting Tools

Manual of SF6 Comprehensive Tester

Analogue and Digital Mass Flow Meters and Controllers for Gases MASS-STREAM

Exercise 2-2. Second-Order Interacting Processes EXERCISE OBJECTIVE DISCUSSION OUTLINE. The actual setup DISCUSSION

This multi-functional device allows the determination of up to six quality parameters with only one measurement:

Features. Main Voltage: Vdc. Input Control Signal: 0-5 Vdc or 4-20 madc (Sourcing) Monitor Output Voltage: 0-5 Vdc or 4-20 madc (Sourcing)

Brooks TMF-Zone 1 Models 5816-Ex/5864-Ex

analytical bulk flow distance FLOW level pressure temperature industrial communication

GasSense NDIR User Manual

BAROMETER PRESSURE STANDARD PRESSURE CONTROLLER

White Paper. Chemical Sensor vs NDIR - Overview: NDIR Technology:

CONTROL and INSTRUMENTATION

Model EXAxt AV550G. Averaging Oxygen Analyzer

Oxymax COS61/COS61D. Technical Information

Experiment AMe-1: Small Animal Respiratory Exchange Ratio (RER)

Overview. Front Panel: Keypad and Display

Intelligent SUNTEX DC-5310(RS) Dissolved Oxygen Transmitter

Appendix D: SOP of INNOVA 1412 Photoacoustic Multi-Gas Monitor. Description and Principle of Operation

The M-Series Eletta Flow Meter High accuracy DP Flow Meter with multiple functions

EuroFID Total Hydrocarbon Analyzer. Precise Determination of Total Hydrocarbons in Air for Corrosive as well as Condensing Gases

EPP4 Pressure Regulator Basic G 1/4"

GP1 & GP2. Electropneumatic Regulators FOR PRESSURE CONTROL TO 1,000 PSI

TEL/jlRE" Introduction. Display Features and Modes. Startup Procedure. Power-Up Procedure. Adjustment Modes

TH-1800-T TRX-700-CNG Converter

Columbus Instruments

TEK-THERMAL 1700B. Thermal Mass Flowmeter. FLOW. Technology Solutions

Applications Note: Use of "pentane equivalent" calibration gas mixtures

Mass Flowmeters. Mass Flowmeters for Gases

Experiment AMe-1: Small Animal Respiratory Exchange Ratio (RER)

AC : MEASUREMENT OF HYDROGEN IN HELIUM FLOW

Mass Flow Controllers

Review of the Hall B Gas System Hardware. George Jacobs

better measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars.

ONSITE PROVING OF GAS METERS. Daniel J. Rudroff WFMS Inc West Bellfort Sugar Land, Texas. Introduction

Precision pressure sensor Basic version Model CPT6020

Improve Process Reliability

Mass Flow Controller (MFC) for Gases

Mass Flow Meter (MFM) for gases

HIGH ACCURACY MULTI-GAS MONITORING USING AUTOMATED SELF- CALIBRATION

Mass Spec will not Autotune

973-SF 6 Analyzer. Precise and Stable SF 6 Gas Analyzer REFLECTING YOUR STANDARDS

Digital Mass Flow Meters and Controllers for Gases

OXYGEN MONITORING SYSTEM OMS

Operation manual Oxygen sensor

MASS FLOW SYSTEMS MASS FLOW MEASURING, CONTROLLING AND BLENDING SYSTEMS

SCAM T.P.E. WATER TREATMENT SYSTEM SWT- AP AUTOMATIC PURGE

Highest Quality. Gas Chlorination Systems

Understanding the Issues Affecting the Accuracy of Measuring Oxygen Consumption Utilizing Metabolic Carts

Continuous Gas Analysis In situ laser gas analyzers TÜV and MCERTS add-on for LDS 6 operating instructions Compact Operating Instructions

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI

O3 3E 1 F Gas Sensor Module

ABB MEASUREMENT & ANALYTICS DATA SHEET. Advance Optima AO2000 Series Continuous gas analyzers

Exercise 5-2. Bubblers EXERCISE OBJECTIVE DISCUSSION OUTLINE. Bubblers DISCUSSION. Learn to measure the level in a vessel using a bubbler.

Advanced Test Equipment Rentals ATEC (2832)

THE FUNDAMENTALS OF THE AIR SAMPLER CALIBRATION-VERIFICATION PROCESS

Technical Support Note

CO 2. (R744) Service Station Presentation. Contents. Goals Basic functions Specification Recovery R477 Vacuum Charge Safety Other features Prototype

Instruction Manual. PLT Series. 1. General Specification. 2. Installation. 3. Wiring. 4. Function. 5. Setting & Calibration

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

USING THE CS400/CS405 (KPSI SERIES 169/173) SUBMERSIBLE PRESSURE TRANSDUCER WITH CAMPBELL SCIENTIFIC DATALOGGERS INSTRUCTION MANUAL

LINEAR TRANSFORMATION APPLIED TO THE CALIBRATION OF ANALYTES IN VARIOUS MATRICES USING A TOTAL HYDROCARBON (THC) ANALYZER

TELEDYNE HASTINGS INSTRUMENTS PRELIMINARY BULLETIN. Models HFM-D-301 & 305, HFC-D-303 & 307

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

THE INSIDE STORY OF THE F-SERIES:

Topics For Discussion Acadiana Gas Measurement School

Instruction Bulletin Addendum For Pressure-Balanced In Situ Oxygen Probes

APPLICATION NOTES DELOMATIC 4, DM-4 GAS

Micro Motion 3098 Gas Specific Gravity Meter

Advance Optima AO2000 Series Continuous gas analyzers Models AO2020, AO2040. Measurement made easy. Modular continuous gas analyzers

Mass Flow Meter (MFM) for Gases

780S Ultra High Purity Series

HumiSys HF High Flow RH Generator

AMT-Ex Dewpoint Transmitter

Flow metering in gases Introduction to COMBIMASS family

Instruction and Maintenance Manual

HI 2314 HI 2315 HI 23151

Diagnosing EVAP systems By: Bernie Thompson

CHAPTER 16 %UHDWKLQJ*DV0L[LQJ3URFHGXUHV

TSE Blood Pressure Monitor Invasive series

Electronic Volume Correctors

ONSITE PROVING OF GAS TURBINE METERS Daniel J. Rudroff Invensys Metering Systems

Max-Trak Model 180. Technical Data Sheet. NEMA 6 / IP67 Compliant Industrial Mass Flow Meters and Controllers For Gases

Long term stability tests of INO RPC prototypes

UBEC 1AT. AUTO TANK Fill System Installation, Operation, & Setup Instructions

Application Note AN-107

Coriolis Mass Flow Meter

TR Electronic Pressure Regulator. User s Manual

SEC Signature DIR Process Monitor

Gas Sampling Fitting with MK2.1 and L-Probe

The Discussion of this exercise covers the following points:

INSTALLATION & MAINTENANCE INSTRUCTIONS

BI-680 Online Dissolved Oxygen Controller Instruction Manual

LK-SX CO 2 +VOC. Application. Security Advice Caution. Notes on Disposal

REASONS FOR THE DEVELOPMENT

Practical approach and problems in in-situ RGA calibration

Transient Fuel-Film Compensation Strategy of PFI Gasoline Engine Based on Combined Film Model

CDS-2000 CO 2 Sensor Verification, Calibration, and Troubleshooting Bulletin

Description. Chassis. Cabinet. Long chassis - Type: Dimensions (mm): 2700 x 1200 x 1678

Pneumatic high-pressure controller Model CPC7000

Transcription:

Air-Fuel Ratio Measurement using Ceramic Sensors Dr. Ronald S. Patrick ECM, Engine Control and Monitoring Company Los Altos, CA, USA ron.patrick@ecm-co.com www.ecm-co.com August, 2008

AFR: Definition Two Definitions Used but Several Values Calculated 1. AFR = Mass Airflow/Mass Fuelflow A direct measurement Conservation of mass is compelling 2. Gas Bench Calculated AFR (C,H,O,N balances) An indirect measurement What calculation (Brettschneider, FAFN, )? What assumptions? What bench? Recall: λ = AFR/AFRstoichiometric AFRstoichiometric calculated from fuel composition

Ford Data (SAE Paper 2003-01-0566) 0.2 AFR Error

What do you want to Report: AFRmass or AFRbench? AFRmass is historically what people wanted to match. It can be verified by measurements of fuel and air mass flowrates. AFRbench should compare to gas bench methods (i.e. C, H, O, N balance techniques). But many details (ex. formula, equilibrium assumptions, HC assumptions) result in different calculated AFR numbers. Which one do you want to match?

One Car Company s Data 0.4 AFR Error

My Point Here The AFR meter is going to output an AFR number. Done right, it will be a consistent and repeatable number. We can consistently match anything. What do you want to match? AFR measured by mass/mass methods will generally result in the same number no matter where and who does it. It s a relatively simple measurement. AFR measured by bench methods will vary from organization to organization and each one will swear that their method is the correct one. The differences are in the details and there are a lot of details.

How the AFR Sensor Works Exhaust Lean: O2 Rich: CO, H2, HC Exhaust diffuses into Detection Cavity O2 pumped into and out of Cavity to maintain equilibrium λ=1 in cavity as detected by the Vs voltage. Equilibrium λ=1 means negligible O2, CO, H2, and HC. So for lean mixtures, you are pumping O2 out and for rich mixtures you are pumping O2 in to burn the CO, H2, HC. Pumping measured by Ip.

NTK UEGO Diffusion Passage BOSCH LSU

Important AFR Sensor Assumptions By the time exhaust has diffused into the cavity, it is at equilibrium conditions. i.e. Lean mixtures contain negligible CO, H2, HC, but there is O2 Rich mixtures contain negligible O2, but there is CO, H2, HC Therefore, the sensor s pumping current Ip is only proportional to equilibrium O2 in the exhaust when lean and only proportional to equilibrium CO, H2, HC in the exhaust when rich. For lean mixtures if you can infer an %O2 based on the sensor s pumping current, you can back-calculate the AFR. For rich mixtures, if you infer a %CO, %H2, %HC based on the sensor s pumping current, you can back-calculate the AFR. Mathematics to derive AFR from Ip are similar to a specific gas bench calculation. Various tweeks will make it match anything. So you can tweek it to match mass/mass and you can tweek it to match any bench. Generally tweeks are of the form: λ = λcalc + f(λ). ECM delta table = f(λ).

AFR Sensor Calculation (Lean Calculation, No Oxygen or Nitrogen in Fuel, Equilibrium at 750 C, 1 Atm.) C 1 H m + λ(1 + m/4)(o 2 + 3.773N 2 ) CO 2 + ao 2 + bh 2 O + cn 2 Conservation of O2: λ (1 + m/4) = 1 + a + b/2 Conservation of H: m = 2b Conservation of N2: λ ( 1 + m/4) 3.773 = c Xo2 = %O2/100 = a / (1 + a + b + c), Note: Wet %O2 (water b in denominator). After some math: λ = (z + Xo2 (m/4)) / (z (1 4.773 Xo2)), where z = 1 + (m/4), Xo2 = %O2/100 How to get Xo2?: Ip (sensor current) = %O2 x [ma/%o2], where [ma/%o2] is the gain of the sensor Rich calculation more complex: No O2. CO, H2, and HC included. Water-gas equilibrium equation. Need CO, H2, and HC gains of sensor: Ip = -(%H2[mA/%H2] + %CO[mA/%CO] + %HC[mA/%HC])

Let s Put in Some Humidity (Lean Calculation, No Oxygen or Nitrogen in Fuel, Equilibrium at 750 C, 1 Atm.) C 1 H m + λ(1 + 1.85/4)(O 2 + 3.773N 2 ) + d H 2 O CO 2 + ao 2 + bh 2 O + cn 2 Conservation of O2: λ (1 + m/4) + d/2 = 1 + a + b/2 Conservation of H: m + 2d = 2b Conservation of N2: λ ( 1 + m/4) 3.773 = c Xo2 = %O2/100 = a / (1 + a + b + c) After some math: Another equation. Actually two equations (AFR(dry), AFR(wet)). Ex.: Using formula on previous page, with m = 1.85, true λ = 1.2 (AFR = 17.47), and air at 70 F, 100% humidity, you would calculate λ = 1.194 (AFR = 17.39). In other words: an error of less than 0.1 AFR. Effect of humidity is to reduce %O2 in exhaust.

How to Get: [ma/%o2], [ma/co], [ma/h2], [ma/hc]? 1. Put known concentration of %O2 (or CO, H2, HC) outside sensor. 2. Measure resultant Ip from sensor as O2 (or CO, H2, HC) diffuses into sensor. Sensor will reduce the %s of these species to negligible number. Ip is linear with O2, CO, H2, or HC and there is a negligible offset. Therefore, the greater the value of O2 (or CO, H2, HC) used, the greater the accuracy. i.e. +-0.1%O2 at 20% O2 means +-0.05 at 10%. Due to sensor electrode characteristics, there is a threshold effect of H2O on these gains. You will need a little known H2O in your known concentrations. i.e. Don t use tanks of pure air. There is no water.

The Case for Calibrating with Air Using air to determine [ma/%o2] is good for 3 reasons: 1. Extremely accurately known (20.945 humidity) 2. Already contains H2O 3. Cheap Little known fact: [ma/%x]/[ma/%o2] = Constant. This means that you do not have to cal lean then cal rich. They scale. Diffusion passage is very large relative to molecular size. If a bigger hole lets in twice as much O2, it will let in twice as much CO, H2, and HC.

In other words Take any one of these NTK, Bosch, or Delphi sensors, calibrate it in air, and run it rich and lean in an engine and you re going to get very similar AFR numbers. 1 1 ±0.1 AFR (less than ±0.01 λ) if using an ECM product.

Easy to Calculate %O2 in Air Does humidity calculation for you!

One click and sensor is calibrated. Now put back in stock for use. Easy to Calibrate

ECM Programmable Calibration Memory ECM sensors have memory chip in sensor connector Memory chip stores identification, calibration, and pressure compensation information Memory allows uniform company-wide calibration to be performed in central location Extends usable life (i.e. accuracy) of sensor through recalibration

Versus Non-Programmable Calibration Ip (O2 pumping current) + + - + ~Ip_normalized Resistor trimmed to scale Ip onto normalized Ip curve. This compensates for diffusion passage size of that sensor when new. Resistor incorrect when sensor ages and results in drift

Does Calibration Drift? Yes, little holes plug when in the exhaust of an engine.

How the AFR Meter Works λ ~ Ip x [%O2/mA] x [λ(%o2)] + f(λ) AFR meter electronics measures Ip. You test ability of electronics to do this using ECM Sensor Simulator. Calibration of sensor tells you [%O2/mA] and through association [%X/mA] The fundamental sensor calculations Optional tweek. Match anything. With no tweek, we match mass/mass. Note that the AFR meter operation is verifiable. You can check the ability of the electronics to measure Ip using the sensor simulator, you can calibrate the sensor, and you can match AFRmass or AFRbench of any bench.

Optional Tweek: Match Anything Delta Table f(λ)

But What is the biggest source of error when using ceramic sensors for AFR determination?

The Dirty Secret of AFR Sensors: Pressure Sensitivity Effect of 35 kpa (5 psi, i.e. nothing ) change in exhaust pressure: 1. Error of 0.02 Lambda at λ = 0.68 (cold start or catalyst cooling) 2. Error of 0.01 Lambda at λ = 0.84 (maximum power) 3. Negligible error at λ = 1 (stoichiometric) 4. Error of 0.1 Lambda at λ = 1.7 (lean-burn port injection) 5. Error of 0.6 Lambda at λ = 3 (gasoline direct injection or diesel) 6. Error of 4 Lambda at λ = 6 (light load diesel)

Solution to Pressure Problem Use Pressure Compensation (P-comp) for non λ = 1 operation, especially lean-burn and diesel applications.

Recommendations Standardized location (Before catalyst (i.e. engine-out). Minimum distance from exhaust valve and minimum distance from exit of exhaust) Standardized calibration (air minus humidity, time) Standardized calculation and delta table to match mass/mass or a specific bench Pressure Compensation (LambdaCAN + Pcomp) Optional: Use most durable sensor (NTK 6mA) Optional: Do humidity compensation (ECM BaroCAN) Optional: Set maximum hours of sensor use

Types of Ceramic Exhaust Sensors EGO/HEGO: λ=1, Nernst Type,1~4 Wire AFR/Lambda/UEGO: Wideband λ, 5 or 6 Wire NOx/O2: 6 or 8 Wire NH3: 6 Wire In development: Soot, CO, HC

NOx Sensor Operation Ip 2 AFR Sensor NOx Sensor 1 st Cavity 2 nd Cavity NOx 1 st Cavity: Control to λ=1 2 nd Cavity: Strip oxygen from NOx and λ=1 O 2

The Scoop on NOx Sensors ±15ppm accuracy 1 Sensitivity to NH3 (same for bench CLA) Lean okay. Rich use less charted. Thermal sensitivities (exh pipe, gas) 1 For new Type G NOx Systems (Q3/2008)

EGR Fast Portable

New Instruments from ECM 6 Analog Out CAN RS232

EGR 5210, Lambda 5220, EGR 5230 Analyzers COMM/ PWR COMM/ PWR CAN Measurement Modules Power Display Head Analog Out Panel Mount

LambdaCAN and NOxCAN Systems CAN Power Sensor Cable Extensions

Easily build Sophisticated Lambda and NOx Measurement Systems CAN Power Example: 5 Channel (3 LambdaCAN, 2 NOxCAN) Pressure Compensated System

Eight-Channel LambdaCAN System LambdaCAN and NOxCAN Kit Contents

Dashboard Display for CAN Networks

Prototype Multi-Channel Lambda Attack Cart with Integral Sampling Pump Cable Hangers LambdaCAN Controllers Pump Manifold Power Supply Pump

ECM Advantage Versatility Suitable for dynamometer and in-vehicle use Modular. Easily build multi-channel systems. Widest measurement range. Fastest response. Can use NTK, Bosch, and Delphi sensors for Lambda, AFR, %O2 Can use NTK and NGK NOx sensors All parameters including raw sensor data (Ip, Rpvs, Age Factor) available Programmable fuels (H:C, O:C, N:C, and H 2 ), sensor control (Rpvs, etc), and delta All ceramic sensors factory calibrated and user can easily recalibrate (memory chip) Optional automatic pressure-compensation and humidity-compensation Supports complete in-house system calibration and verification CAN, Analog Outputs (6 ch.), RS232, USB Programmable CAN communication. Broadcast and CANopen..DBC produced. Compatible with ETAS INCA (as Add-on) and ATI Vision