DOMESTIC HOT WATER TEMPERATURE CONTROL with SAFEGUARD

Similar documents
LEAD FREE * Product Specification. Features n. Specifications n. Relay Specification n ! WARNING NOTICE

Scalding Now a Healthcare Worry Legionella Cases on the Rise Aging Population Safety Issues Hidden Costs of Status Quo ASSE 1016 Update

BUBBLER CONTROL SYSTEM

Water Temperature Control - Groups of Fixtures

Simple Set. Pressure Independent Control Valves 2 Way 1/2-2

SINGLE VALVE WITH LOW-FLOW BYPASS

Simple Set Max. Pressure Independent Control Valves 2 Way 2-1/ /09/18

combustion efficiency monitoring Flue gas oxygen analyzers General Purpose Applications Combustion & Environmental Monitoring

combustion efficiency monitoring General Purpose Applications Flue gas oxygen analyzers Combustion & Environmental Monitoring An Company

Autocalibration Systems For In Situ Oxygen Analyzers

BUBBLER CONTROL SYSTEM

UBEC 1AT. AUTO TANK Fill System Installation, Operation, & Setup Instructions

Pressure and/or Temperature Pilot Operated Steam Regulators Series 2000

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

Applications. Features AWWA ULTRASONIC WATER METER

HumiSys HF High Flow RH Generator

CALEFFI. LEGIOMIX Electronic mixing valve series 01086/18.2 NA

SSL. Smart Valve Positioner.

Series e700 Combination T/P Valve Provides Unsurpassed Protection from Temperature & Pressure

SSR. Smart Valve Positioner.

Pro-V Multivariable Flowmeter

Intelligent SUNTEX DC-5310(RS) Dissolved Oxygen Transmitter

Flow and Energy Measurement F-5400 THERMAL MASS FLOW METER

B LCTV_v3 4/27/04 10:54 AM Page 1 Series e700

PumpAgents.com - Click here for Pricing/Ordering Nominal psi (bar) Cut-In Cut-Out

SonoMeter 30 Energy Meters

780S Ultra High Purity Series

Summary of Substantive Changes between the 2012 and 2018 editions of CSA B125.3 Plumbing Fittings

Pro-V Multivariable Flowmeter Model M22 In-line Vortex

Required Indoor Draft Hood. Optional Outdoor Vent Cap

Model EXAxt AV550G. Averaging Oxygen Analyzer

Pro-V Multivariable Flowmeter Model M22 In-line Vortex

UltraLo 1800 Alpha Particle Counter

SPECIFICATIONS ATTENTION

Analogue and Digital Mass Flow Meters and Controllers for Gases MASS-STREAM

PanaFlow MV82. Insertion Style Multivariable Flowmeter. GE Measurement & Control. Key Benefits. Applications

CONTROL VALVE TESTING

Autocalibration Systems for In Situ Oxygen Analyzers

Performa Cv Twin Alternating and High Flow Systems. Manual Supplement

BERMAD Waterworks. Level Control Valve with Altitude Pilot. 700 Series. Model X. Features and Benefits. Major Additional Features

DTG - LCD Digital Temperature Gauge USER MANUAL

O.K. Safety first CDN USA. Table of Contents. Approvals. Attention IFGC CSA UL ANSI NFPA

PART 1 GENERAL..2 Components of the gas chlorination system include, but are not limited to the following:

PoolWarden MiniWarden SmarterPool

TECHNICAL DATA Q= C. Table 1 - Specifications

Valve Proving System VDK 200 A S06*

CVI Valve Line. Exceeds the industry s highest standards for reliability and performance

AC : MEASUREMENT OF HYDROGEN IN HELIUM FLOW

TANK MANAGER FOR TWO TANKS OPERATING MANUAL. 10/31/11 C-More T6C L color touch panel

TECHNICAL DATA. TRIMPAC Model B-5 & B-5B

Valve Proving System VDK 200 A S02

ECS Protector Nitrogen Generator PGEN-30 (PGEN-30E)

TECHNICAL DATA. Pressure Regulation 531a. April 24, 2009

Hot extractive multi-channel gas analyser for continuous process and emissions monitoring.

ACV-10 Automatic Control Valve

CAPITAL CONTROLS SERIES NXT3000

TECHNICAL DATA. Page 1 of 12

TECHNICAL DATA. Q= Cv S

UPGRADABLE PRESSURE BALANCE BAT/SOWER FITTING VOLUME AND TEMPERATURE CONTROL VALVE 1-5/8" TO 3-1/ ROUG VALVE OPTIONS 1/2" NPT 1/2" NOM or 1/2" NOM or

Z, Y, and X PURGE INDICATORS / CONTROLLERS

Cover Page for Lab Report Group Portion. Pump Performance

DS06D,G Dial Set Pressure Regulating Valve

Controller for boilers Galan - regulator for management of heating elements and circuit SolarSentinel-DBTW User guide

Presented to the IAPMO Standards Review Committee on March 7, 2016

Hot extractive multi-channel gas analyser for continuous process and emissions monitoring.

Reverse Osmosis System Installation Guide and Operation Manual.

ASSE International Product (Seal) Listing Program

Liquid Level Controllers

INSTRUCTION MANUAL Pressure Relief Device LPT

CFC2. Float Control For Closed Tanks MODEL. Specifications. Dimensions (In Inches) Reservoir Connection 1" NPT (Typ. Both Ends 2 Places)

INSTALLATION INSTRUCTIONS 1/2 THERMOSTATIC VALVE AND TRIM

Mass Flow Controller (MFC) for Gases

TECHNICAL DATA. Q = C v P S

BRILLIANT WONDERS LED BUBBLERS INSTALLATION INSTRUCTIONS & PRODUCT MANUAL CMP SERIES

Harmony. Pressure Independent Balancing and Control Valve

Technical Data Sheet High Performance Digital Gas Mass Flow Meters and Controllers Features Description

TECHNICAL DATA 3 MODEL G-3000 DRY VALVE RISER ASSEMBLY

Scald Protection 3-Way Thermostatic Mixing Valve

Installation and Operation Manual

TECHNICAL DATA. Trimpac 244a. September 16, 2013

MOYNO FLUID DETECTION CONTROL SERVICE MANUAL. Section: ACCESSORIES. Page: 1 of 8 Date: May 1, 1998 GENERAL

TECHNICAL DATA Q = C. v P S. 2 Model G-2000 Dry valve. Page 1 of 13

FAS-W. Features. Applications. Automatic condensation hygrometer

Multiple Pressure Booster Systems With Variable Speed Controller Type BL

WATER HEATER THERMAL EXPANSION TANKS Owner s Manual. Safety Instructions Installation Maintenance Warranty. Models: 2-5 Gallon Capacity

DS05C,D,G Dial Set Pressure Regulating Valves

Dosing & Granudos. Controllers. Chemical Storage. Chemical. Dosing &

TECHNICAL DATA. Trimpac 257a. September 16, 2013

Butterfly Control Valve. DMK/6 Series

TECHNICAL DATA. Table 1 - Specifications

Manual Oxygen Analyzer A4009T

CO2 incubator with additional process controls

BACK PRESSURE / SUSTAINING

Variable Area Flow Meters

TECHNICAL DATA. Trimpac 251a. Spetember 16, 2013

HEATEC TEC-NOTE Publication No Revised

Brooks TMF-Zone 1 Models 5816-Ex/5864-Ex

Air Amplifiers & SYSTEMS

VB-7212 Series. Application. Features. Applicable Literature. 5/8" O.D., 45 SAE Flared Stem Up Open, Two-Way Valves General Instructions

Automatic Valve Proving Control

Transcription:

ETV Platinum Plus R C O R P O R A T I O N Electronic Tempering Valve DOMESTIC HOT WATER TEMPERATURE CONTROL with SAFEGUARD Conforms to the following: ASSE 1017 California Lead Free Plumbing Law CSA B 125.3 (NSF/ANSI 61 Section 8) The ETV Platinum Plus can operate in one of the following modes: Stainless Steel Valve Bodies Conforms to Lead Free Requirements ETV (Temperature Control) Rugged Body Design TMC (Alarm Condition Safeguard) Minimizes Scale Build up ETV Combo (Temperature Control with Alarm Condition Safeguard) External Mounted Actuator Designed for critical temperature applications Safeguard against high temperature conditions Optional Safety Valve Output Accurately maintains set point from 0.5 gpm domestic draw to full flow Accurately maintains set point within +/-2 ºF Dual Alarm Outputs Remote Communication Options Domestic Hot Water Temperature Control Internet (Heat-Timer RINET) Heating & Cooling or Industrial Applications BACnet (IP or MSTP) ModBus 20 New Dutch Lane, Fairfield, NJ 07004 Phone: 973-575-4004 Fax: 973-575-4052 www.heat-timer.com 056305-00 B

Why ETV Platinum Plus is Important Legionella Selection and controlling proper water temperature in domestic water storage and delivery systems is important in preventing illness from water-borne bacteria such as Legionella. Legionellae Growth Chart* Ideal growth range 95 115 F Legionellae growth range 68 122 F Rapid Kill Range 158 176 F 50 F 75 F 100 F 125 F 150 F 175 F Scald Hazard Scald hazards can be created in domestic water distribution systems when not properly controlled or monitored. Fluctuations Is the rapid and uncomfortable change in water temperature experienced at the faucet or shower by the end-user, which can lead to a fall or serious injury due to the thermal shock. Below 68 F, Legionellae can survive but are dormant. Cold water in storage tanks, piping, decorative fountains, and other equipment should ideally be kept below 68 F. Hot water need capability of heating water to 158 F for disinfection 151 F Legionellae die within 2 minutes 140 F Legionellae die within 32 minutes 131 F Legionellae die within 5 6 hours Above 122 F Legionellae can survive but do not multiply Scald Hazard The ETV Platinum PLUS allows the domestic water system to be stored at higher temperatures to prevent the growth of Legionella, while being able to control and deliver a consistent tempered water out to the building. Water Temperature ( F) Time to 3rd Degree Burn* 155 1 second 148 2 seconds 140 5 seconds 133 15 seconds 127 1 minute 124 3 minutes 120 5 minutes 100 Safe temperature for bathing *As per www.asse-plumbing.org and www.osha.gov ETV Platinum Plus Advantage Digital Temperature Control Accurately maintains set point from 0.5 gpm domestic draw to full flow per ASSE 1017 Quick Startup Single set point input, no multiple valve settings or balancing required Multiple Valve Sizes 7 Valve Sizes allow proper size selection for desired flow rates Multiple valves setup option for larger systems Maintenance Free The stainless valve body design reduces scale build up The external mounting of the actuator provides easy access There are no gaskets to maintain or replace as there are no motor to water contact concerns 2 Control Settings & Menu Field Accessible No laptop or dedicated software required Flexibility of Installation HOT and COLD valve connections are interchangeable Single Control Multiple Valves A single control module can control multiple valves in high flow applications 7 Day Scheduling with 4 Daily Setbacks Capability to lower outlet set point during low usage periods Weekly schedule with 4 daily setbacks for maximum energy efficiency Remote Communication Options Internet (Heat-Timer RINET) BACnet (IP or MSTP) ModBus 056305-00 B

ETV Platinum Plus Applications Hospitals and Nursing Facilities Hotels and Resorts Correctional Prison Facilities Military Installation Barracks School Educational Buildings Dorms Multi Family Buildings Office Buildings Industrial Processes ETV Platinum Plus Actuator External Mounting to Valve Body Eliminates the potential of motor to water contact Eliminates the need for gasket maintenance or replacement Smart Calibration Prevents motor damage due to over-torque conditions One motor fits all sizes Reverse Direction Capability Allows the HOT and COLD inlets of the valve to be interchangeable ETV Platinum Plus Remote Communication Options Internet Access Internet access through Heat-Timer s Internet Communication Management System (ICMS) Receive system critical alarms as an email or text message No license fees or special software required Building Automation Systems (BAS) Supports BACnet and ModBus protocols Read and write access to control setting and temperature readings 3 056305-00 B

ETV Platinum Plus Layout Led Indicates the Associated Output Status Digital Display Shows Sensor Temperatures, Set Point, Valve Modulation Buttons Functions Change Based on Current Screen 120 VAC Power Supply Remote Communication 24V Actuator Power Supply Temperature Sensor Inputs Safety Valve & Alarm Outputs Motorized Valve Modulating Signal ETV Platinum Plus Dimensional 7 ¾ Maintain 18 Inches Minimum ETV Assembly Dimension A B C D ½ 3 1 /8 2 10 ½ 2 3 /8 ¾ 3 1 /8 2 10 5 /8 2 3 /8 1 4 2 1 /8 10 3 /4 2 3 /8 1 ¼ 4 2 ½ 11 2 3 /8 1 ½ 13 4 /5 2 4 /5 11 3 /16 2 3 /8 2 5 ½ 3 3 /8 11 3 /8 2 3 /8 C 2 ½ 6 5 /16 4 2 3 /4 2 3 /8 B COLD HOT A MIXED 4 ¾ D ETV Assembly Valve Connections NPSC HOT COLD MIXED ½ ½ ½ ½ ¾ ¾ ¾ ¾ 1 1 1 1 1 ¼ 1 ¼ 1 ¼ 1 ¼ 1 ½ 1 ½ 1 ½ 1 ½ 2 2 2 2 2 ½ 2 ½ 2 ½ 2 ½ 4 056305-00 B

ETV Platinum Plus Specifications ETV Platinum PLUS Control Module Voltage Input: 120 VAC 60 Hz Maximum Input Rating: 48 VA max Display: Graphic Display Display/Temperature Units: F and C Modes of Operation: ETV, TMC, ETV+TMC Combo ETV Set Point: 40 F / 4 C to 200 F / 93 C Alarm Set Point: 40 F / 4 C to 200 F / 93 C Modulation Output Signal: 0 10V, 2 10V, 0 5V, 1 5V, 4 20mA LED Indicators: 3 (Actuator Signal, No Flow, Alarm Status) Inputs: Sensors (Hot, Cold, Mixed), Flow Prove, EMS 4 20mA Dimensions: 11 W x 9 H x 3 ¾ D Weight: 2.5 lbs. ETV Platinum PLUS Actuator Voltage Input: 24 VAC 60 Hz Power Consumption: 18 VA maximum Input Signal: 0 10 V Weight: 2.6 lbs. ETV Platinum PLUS Valve Body Body & Trim: 304 Stainless Maximum Operating Temperature: 300 F / 149 C Maximum Working Pressure: 225 psi Stem Material: 640 Stainless ETV Platinum Plus Sizing ETV Platinum PLUS Stainless Steel Valve Pressure Valve Size Drop psi ½ ¾ 1 1 ¼ 1 ½ 2 2 ½ Cv 5 7 12 18 29 46 73 3 8 12 20 32 50 80 126 4 9 15 23 37 58 93 145 5 10 16 26 41 64 103 162 6 12 18 28 45 71 113 178 7 13 20 31 50 78 125 192 8 14 21 33 53 83 132 205 9 15 22 35 56 88 140 218 10 16 23 36 58 91 145 230 11 17 24 38 62 97 154 241 12 18 25 40 64 100 160 252 Bldg Recirc* Gallons Per Minute 5 GPM 10 GPM 15 GPM Pressure Drop ETV Platinum PLUS Safety Valve Description ½ ¾ 1 1 ¼ 1 ½ 2 Cv/1 psi 15 35 60 90 125 240 2 psi 21 50 85 127 177 339 3 psi 26 61 104 156 217 416 4 psi 30 70 120 180 250 480 5 psi 34 78 134 201 280 537 Flow Rate GPM Sizing Recommendation: Heat Timer recommends sizing the stainless valve with a design flow as close as possible to a 5 psi pressure drop. When selecting a Safety Valve it is recommended to use no greater than a 3 psi pressure drop. *Building Recirc: The minimum building recirc flow rate shown is based on valve size and a flow velocity of 4 ft per sec. ETV Platinum Plus Part Numbers Valve Size Complete Assembly Valve/Actuator Transformer TMC Motorized Valve Part Numbers Complete Assembly BACnet Option Complete Assembly ModBus Option Complete Assembly RINET Option ½ 915670-00 915640-00 920540-00 915670-BAC 915670-BUS 915670-RINET ¾ 915671-00 915641-00 920541-00 915671-BAC 915671-BUS 915671-RINET 1 915672-00 915642-00 920542-00 915672-BAC 915672-BUS 915672-RINET 1 ¼ 915673-00 915643-00 920543-00 915673-BAC 915673-BUS 915673-RINET 1 ½ 915674-00 915644-00 920544-00 915674-BAC 915674-BUS 915674-RINET 2 915675-00 915645-00 920545-00 915675-BAC 915675-BUS 915675-RINET 2 ½ 915676-00 915646-00 920546-00 915676-BAC 915676-BUS 915676-RINET Complete Assembly includes sensor, stainless valve, actuator and control module. Valve/Actuator for multiple valve applications. 5 056305-00 B

ETV Platinum Plus Piping with Optional Safety Valve COLD COLD Water WATER Supply SUPPLY COLD WATER Building SUPPLY Loop Return RECIRCULATION Recirculation Pump PUMP (CONTINUOUS (Continuous RUNNING) Running) Check Valve CHECK VALVE (typ) (TYP) THERMAL Thermal TRAP Trap 32" 32 Min. MIN. VERTICAL Vertical Drop DROP LC to TO LC ETV PLATINUM Platinum PLUS CONTROL Control Module MODULE ETV ACTUATOR ETV Actuator / / Valve VALVE ASSEMBLY Assembly Optional OPTIONAL COLD Immersion PROBE SENSOR Sensor Union UNION (typ) (TYP) DRAIN Drain COCK Cock (TYP) (typ) S OPTIONAL SAFETY VALVE OPTIONAL Optional HOT Sensor PROBE SENSOR Water Heater WATER HEATER / HOT Hot WATER Water SOURCE Source System SYSTEM MIXED Immersion PROBE SENSOR Sensor For link to ETV Platinum Plus manual scan 6 056305-00 B