A/C SYSTEM GENERAL DIAGNOSTIC PROCEDURES

Similar documents
A/C SYSTEM DIAGNOSIS

COMPRESSOR REPLACEMENT PROCEDURE (R-134A)

OPERATION MANUAL RTI RHS650 RTI TECHNOLOGIES, INC East Market Street York, PA Manual P/N

Troubleshooting Guide. Pg. 1

SILENTAIRE TECHNOLOGY

SILENTAIRE TECHNOLOGY

AE R8 December 2004 Reformatted November Copelametic Two-Stage Compressors Application and Service Instructions

OPERATING INSTRUCTIONS

Using P-T Analysis As A Service Tool

AMP Oil Free Manual AMP 50-8-TC AMP 50-6-D AMP General User and Maintenance Instructions

R-410A 50% R-32 50% R-125.

SPECIFICATIONS Type: Twin stack, single phase Tank: 4 gallon Air Output: PSI; PSI Max PSI: 125 PSI HP: 1.

BIMA cryogenics (Dick Plambeck, 18jan2007)

Bulletin TCR-104 & 109 Filling and adding to the Glycol pressure system

Inert Air (N2) Systems Manual

TECHNICAL BULLETIN DESIGNING A FUNCTIONAL COMPRESSED AIR SYSTEM

Propane Conversion Kit Instructions

ATD LB PRESSURE BLASTER INSTRUCTION MANUAL

CRYOGENIC EXPERTS, INC. World Wide Web Toll Free FOR CEXI Phone (805) Facsimile (805)

Easy Nest Kits. Installation Suggestions

AIR BRAKE SYSTEM TROUBLESHOOTING

Instructions for High Altitude Conversion

2 GALLON TWIN STACK AIR COMPRESSOR W/ HOSE REEL

V46 Series 2-Way Pressure-Actuated Water-Regulating Valves With Union Fittings

DC5A. Cyclone Separator Trap for Air. Copyright 2015 by TLV Co., Ltd. All rights reserved ISO 9001/ ISO MA-03 (DC5A) 19 June 2015

42045 Heavy Duty ADA Base Model Kit: 85/105 PSI (ADA Compressor Only) Heavy Duty ADA Base Model Kit: 110/145 PSI (ADA Compressor Only)

HEAD PRESSURE CONTROL VALVES

RG6000. Refrigerant Recovery Machine. Operating Manual. 99 Washington Street Melrose, MA Phone Toll Free

AQUAMATIC EASY NEST KITS INSTALLATION SUGGESTIONS

POWER FLUSH KIT INSTRUCTIONS

Installation and Operation 370ESP (Electric Single-Point Purger) & 370ESPR (Retrofit Purger)

MODEL NUMBER: P PORTABLE COMPRESSOR

Application Engineering Bulletin AE-1301 Issued June, Copeland APPLICATION GUIDELINES FOR ZP**K*E SCROLL COMPRESSORS FOR R-410A

AIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST

MODEL NUMBER: PSI AIR SOURCE KIT 200 PSI Compressor on 2.0 Gallon 200 PSI Air Tank

Conversion instructions from natural gas to propane

MODEL NUMBER: M20005 AIR SOURCE KIT. 30% Duty Compressor on. 2.0 Gallon Air Tank SAVE THIS MANUAL FOR FUTURE REFERENCE

V48 Series 3-Way Pressure-Actuated Water-Regulating Valves With Union Fittings

3 GALLON, OILLESS PANCAKE COMPRESSOR INSTRUCTIONS. Item #31289

R E D I C O N T R O L S

V146 Series 2-Way Pressure-Actuated Water-Regulating Valves

200 PSI FAST-FILL AIR SOURCE KIT

Winter Shut Down Procedure

Installation Instructions

Automatic Non-freeze Valve NF6

BUBBLER CONTROL SYSTEM

RDK-408D2 Cold Head. Technical Manual. SHI-APD Cryogenics Inc Vultee Street Allentown, PA U.S.A. Revision A: September 2005

Sedan Range. Evaporative Loss System Check Clarified Procedure

97C COMPRESSOR KIT 12V PART NO C COMPRESSOR KIT 24V PART NO C COMPRESSOR KIT PART NO

MST21 Stainless Steel Balanced Pressure Thermostatic Steam Trap

TECHNICAL DATA MAINTENANCE AIR COMPRESSOR MODEL G-1

FX134, FX1234, FX3030 Problem and Solutions

400H HARDMOUNT AIR COMPRESSOR KIT PART NO H HARDMOUNT AIR COMPRESSOR KIT PART NO

How to use Solvent Purification System A brief manual

D R A F T. Operating Procedures for the NPDGamma Liquid Hydrogen Target at the BL 13. Version 1.00

Pressure Automated Calibration Equipment

INSTRUCTIONS FOR MODELS SG3897 AND SG3898 CROSS PURGE ASSEMBLIES

MODEL NUMBER: P-A AUTOMATIC PORTABLE COMPRESSOR

Diagnosing EVAP systems By: Bernie Thompson

MODEL NUMBER: P PORTABLE COMPRESSOR

AE R1 February 2015

TECHNICAL DATA SINGLE INTERLOCKED PREACTION SYSTEM WITH PNEUMATIC RELEASE

APPS-160 Gen 2 User Manual

Code AWC20HP Air Compressor

Latvin Luxury Shower Panel. Telephone Product Specification. ~ Minimum Working Pressure 1.0 bar ~ Maximum Working Pressure 3.

200 PSI HIGH-FLOW AIR SOURCE KIT

Quick Start SunPump Install

400C & 450C DUAL PERFORMANCE VALUE PACKS

Aftercooler Owner s Manual

Technology issues regarding Blends of Refrigerants Buffalo Research Laboratory

Natural Gas to L.P. Gas Conversion Kit

BT6HC Hygienic Sanitary Balanced Pressure Steam Trap for High Capacity and CIP/SIP Applications

CO 2. (R744) Service Station Presentation. Contents. Goals Basic functions Specification Recovery R477 Vacuum Charge Safety Other features Prototype

ATL R/V Atlantis AUXILIARY PLANT OPERATION APPENDIX OPERATING PROCEDURES

Glove Box Installation Manual

Thermocirc Installation and Maintenance Instructions

LARGE DRY CHEMICAL, TWIN-AGENT, AFFF, HALON 1211, AND AQUASONIC (NITROGEN-OPERATED SYSTEMS) Pressure Regulator Test Manual

PN-DR. Pneumatic Direct-acting Pressure Reducing Valve for Steam and Air. Copyright 2018 by TLV CO., LTD. All rights reserved

PC1131 Electric Air Compressor

OWNER S MANUAL. Page: 1 of 8

PumpAgents.com - Click here for Pricing/Ordering Nominal psi (bar) Cut-In Cut-Out

24 Litre Air Compressor

SPECIFICATIONS TABLE Maximum Air Pressure 115 PSI Air Tank Capacity 20 Gallons

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO

450P- RV AUTOMATIC PORTABLE COMPRESSOR EXTREME SERIES

TSS21 Sealed Thermostatic Steam Tracer Trap

Eaton Filtration, LLC

OPERATOR S MANUAL Ar-Gone Weld Gas Analyzer

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO

MOYNO FLUID DETECTION CONTROL SERVICE MANUAL. Section: ACCESSORIES. Page: 1 of 8 Date: May 1, 1998 GENERAL

450P AUTOMATIC PORTABLE COMPRESSOR EXTREME SERIES

BUBBLER CONTROL SYSTEM

Your safety and the safety of others are very important.

Natural Gas to L.P. Gas Conversion Kit

2008 by Controlmatik ABW

Operator: Save these instructions for future use!

Bobtail DOT 407 / 412 Vacuum

Operating Instructions

Operator: Save these instructions for future use!

III. Identify the initial installation requirements for standpipe systems

Transcription:

A/C SYSTEM GENERAL DIAGNOSTIC PROCEDURES 1990 Nissan 240SX 1983-90 AIR CONDITIONING & HEAT General Servicing Diagnostic Procedures All Import Makes & Models Diagnosis is an important first step in A/C system servicing. To save time and effort, systems should be carefully checked to identify the causes of poor performance. By using the following diagnostic charts, defective components or system damage can be quickly located. To identify problems that are specific to one system, refer to the repair section of this manual. The charts in this section apply to all systems. ALTITUDE PRESSURE VARIATIONS ALTITUDE PRESSURE VARIATIONS TABLE Altitude Absolute Gauge Altitude (Ft. Above Pressure of Correction Sea Level) Atmosphere (psi) (1) (psi) 0... 14.7... 0 1000... 14.2... -0.5 2000... 13.7... -1.0 3000... 13.2... -1.5 4000... 12.7... -2.0 5000... 12.2... -2.5 6000... 11.7... -3.0 7000... 11.3... -3.4 8000... 10.9... -3.8 9000... 10.5... -4.2 10,000... 10.1... -4.6 (1) - Subtract correction shown from gauge readings. ALTITUDE VACUUM VARIATIONS ALTITUDE VACUUM VARIATIONS TABLE Altitude Absolute Gauge Altitude (Ft. Above Pressure of Correction Sea Level) Atmosphere (psi) (1) (psi) 0... 29.92... 0 1000... 28.92... +1.0 2000... 27.82... +2.1 3000... 26.82... +3.1 4000... 25.82... +4.1 5000... 24.92... +5.0 6000... 23.92... +6.0 7000... 23.02... +6.9 8000... 22.22... +7.7 9000... 21.32... +8.6 10,000... 20.52... +9.4 (1) - Add correction shown to gauge readings.

PREPARATION FOR TESTING 1) Attach Low and High pressure gauges. 2) Start engine and allow to warm up. 3) Set system to "COOL" and blower to "HIGH". 4) Open car doors and hood. 5) Run engine at fast idle for 2-3 minutes. AIR CONDITIONING SYSTEM PERFORMANCE CHECK TABLE PERFORM TESTS: SHOULD BE: IF: Temperature Check Temperature Check Is * Switch to "LOW" blower. * Close doors. * Check outlet temperature. 35-45 F Too warm - Check control lever operation, heater water valve, cooling system and gauge readings. Visual Check Visual Check Shows: * Compressor Quiet, No Leaks Noisy - Check belts, oil level, seals, gaskets, reed valves. * Condenser Free of Obstructions Blocked - Clean off. Plugged - Flush or replace. * Receiver-Drier Dry & warm to touch Frosty - Check for restriction, replace desiccant. * Sight Glass Clear or few bubbles Bubbly, foamy or streaks - Check gauge readings. * High Side Lines Dry & warm to touch Frosty or very hot - Check for restriction or overcharge. * Low Side Lines Dry & cool to touch Frosty or warm - Check for restriction, low charge or bad valve. * Expansion Valve Dry Frosty - Check for moisture or restriction. Check sensing bulb. * STV Dry & cool to touch Frosty or warm - Check gauge readings for valve malfunction. * Evaporator Dry & cold to touch Freezing or warm - Check expansion valve, STV or thermo switch. Gauge Readings Gauge Readings are: * High Side Gauge See Pressure Chart Above or below normal - See A/C Diagnosis. * Low Side Gauge See Pressure Chart Above or below normal - See A/C Diagnosis.

Fig. 1: Ambient Temperature/Pressure A/C Chart

Fig. 2: Evaporator Temperature/Pressure A/C Chart AIR CONDITIONING DIAGNOSIS WITH GAUGES FOR SYSTEMS WITH INSUFFICIENT OR NO COOLING TABLE Low Side High Side Other Symptoms (1) Diagnosis Gauge Gauge NORMAL NORMAL No or few bubbles in sight Some Air and glass. High side gauge may Moisture in

go high. Low side gauge System does not fluctuate with compressor on/off cycle. NORMAL NORMAL Cools okay in morning but Excessive not during hot part of day. Moisture in Bubbles in sight glass. System Discharge air warm when low side gauge drops into vacuum. NORMAL NORMAL Thermostatic switch system Defective only - compressor cycles off Thermostatic and on too rapidly. Switch NORMAL NORMAL Cycling clutch systems only - Misadjusted to compressor doesn t turn on Thermostatic HIGH soon enough. Discharge air Switch or becomes warm as low side pressure rises. Defective Pressure Sensing Switch LOW LOW Bubbles in sight glass. Low R-12 Outlet air slightly cool. Charge LOW LOW Sight glass clear. Outlet Excessively air very warm. Low R-12 Charge LOW LOW Outlet air slightly cool. Expansion Sweating or frost at expansion valve. Valve Stuck Closed Screen Plugged or Sensing Bulb Malfunction LOW LOW Outlet air slightly cool. Restriction High side line cool to touch. on High Side Sweating or frost on high side. LOW HIGH Evaporator outlet pipe cold. STV Stuck Low side goes into vacuum Open when blower is disconnected. HIGH LOW Evaporator outlet pipe warm. STV Stuck Outlet air warm. Closed HIGH LOW Noise from compressor. Compressor Malfunction HIGH HIGH Outlet air warm. Liquid Compressor line very hot. Bubbles in Malfunction sight glass. or R-12 Overcharge HIGH HIGH Outlet air slightly cool. Large Amount Bubbles in sight glass. of Air and Moisture in System HIGH HIGH Outlet air warm. Evaporator Expansion outlet sweating and frost. Valve Stuck Open (1) - If equipped with a low refrigerant charge protection system, compressor operation may have stopped.